Hearing Screening

Total Page:16

File Type:pdf, Size:1020Kb

Hearing Screening Hearing Screening Purpose Screening provides an essential way to identify students who may have educational difficulties due to a hearing loss. Early identification will help to ensure that these students receive appropriate medical follow-up, intervention, and educational services and supports. The Screening Process Schools should screen the hearing of children in these recommended target groups: • Students in nursery, kindergarten and grade 1 • Students referred because of parental or teacher suspicions of hearing loss • Students who are new to the school division/district, especially newcomers to Canada • Students with known hearing problems and those who failed the screening in the previous year • Students who receive additional supports from Resource, and/or Speech and Language services The hearing screening procedure should take a few minutes per child. An audiologist, audiometrist, rehabilitation assistant, trained volunteer or school division staff member (e.g. speech/language pathologist, educational assistant) administers the short screening test using an audiometer. The audiometer produces different pitches (frequencies) of sound at varying loudness levels which are transmitted through headphones to each ear. Children indicate when they hear the sounds by raising their hand or by clapping their hands. Children who respond to all the sounds in both ears receive a ‘pass’. Those who do not should be screened a second time. If a child again does not hear all the sounds, he/she should be referred to an audiologist for a complete hearing assessment. At that time, it will be determined if the child: • has normal hearing but failed the screening for other reasons (e.g. distractions, lack of understanding of the process) • needs medical intervention (e.g. for an ear infection, other medical issues) • has a hearing loss (which may be temporary or permanent) Equipment School divisions are responsible for purchasing their own portable audiometers to use for hearing screening. Information regarding recommended audiometers, repairs and calibration of units are available from the Provincial Audiology Technician in Brandon. The technician can be contacted at 1-204-571-5520. .
Recommended publications
  • Variation in Tone Presentation by Pure Tone Audiometers: the Potential for Error in Screening Audiometry
    Variation in tone presentation by pure tone audiometers: the potential for error in screening audiometry. Christopher Barlow Technology School, Southampton Solent University, Southampton, UK. Lee Davison Technology School, Southampton Solent University, Southampton, UK. Mark Ashmore Strategic Audiology Services, Street, Somerset, UK Summary Manual pure tone audiometry has been in consistent use for a long period of time, and is considered to be the ‘gold standard’ for the assessment of hearing thresholds. Increasing legislative requirements, and a significant global cost impact of noise induced hearing loss, means that a significant amount of reliance is placed on this tool for diagnosis. There are a number of questions regarding the degree of accuracy of pure tone audiometry when undertaken in field conditions, particularly relating to the difference in conditions between laboratory calibration and clinical or industrial screening use. This study assessed the test-retest variability of a number of commercially available screening pure tone audiometers, all with recent calibration, using both laboratory tests and clinical tests in accordance with ISO 8253-1. The results of both lab and clinical studies showed a high level of test-retest variability, with maximum between test variation of 21 decibels at some frequencies in the lab tests, and 35 dB in the clinical tests. Considerable variation occurred at all frequencies, with a particularly high level of variation at 6kHz for all meters. Levels of variation measured in this study suggests a high potential for diagnostic error when using screening pure tone audiometry. Keywords: Audiometry, Calibration, Variance, Hearing Threshold, Audiometer 1. Introduction1 regularly above 85 dB LAeq poses a risk of ‘mild’ hearing damage to most people, with the risk of In the field of audiology, manually operated more severe damage increasing with both length hearing assessment using pure tones according to and level of exposure [5, 6].
    [Show full text]
  • The Australian College of Audiology
    Position Paper on the use of titles and qualifications by members of ACAud Australian College of Audiology (ACAud) members must adhere to the definitions of “audiologist” and “audiometrist” in the Scope of Practice for audiologists and audiometrists when describing their profession/qualifications. To describe their profession/qualifications as an “audiologist” an ACAud member must: 1. Hold a minimum of a Masters of Audiology from an Australian University (or other degree recognised as equivalent by ACAud). For people educated overseas, an Application Examination must also be passed. AND 2. Have completed the ACAud internship program (or other program/work experience recognised as equivalent by ACAud1) in accordance with the ACAud requirements for audiologists. AND 3. Be a current Full/Ordinary Audiologist Member of ACAud who has been awarded the Hearing Rehabilitation Specialist (HRS) and Diagnostic Rehabilitation Specialist (DRS) competencies. To describe their profession/qualifications as an “audiometrist”, an ACAud member must: 1. Hold a minimum of a Diploma of Audiometry from an Australian TAFE (or other qualification recognised as equivalent by ACAud). For people educated overseas, an Application Examination must also be passed. AND 2. Have completed the ACAud internship program (or other program/work experience recognised as equivalent by ACAud1) in accordance with the ACAud requirements for audiometrists. AND 3. Be a current Full/Ordinary Member of ACAud who has been awarded the Hearing Rehabilitation Specialist (HRS) competencies. ACAud members who are entitled to use the title “Doctor” or “Dr” must specify in their post- nominals (after their name) the degree and area of study that allows them to use this title to avoid confusion with qualified medical practitioners and other health practitioners entitled to use the title “Doctor” or “Dr”.
    [Show full text]
  • 8 Hearing Measurement
    8 HEARING MEASUREMENT John R. Franks, Ph.D. Chief, Hearing Loss Prevention Section Engineering and Physical Hazards Branch Division of Applied Research and Technology National Institute for Occupational Safety and Health Robert A. Taft Laboratories 4676 Columbia Parkway Cincinnati, Ohio 45226-1998 USA [email protected] 8.1. INTRODUCTION (RATIONALE FOR AUDIOMETRY) The audiogram is a picture of how a person hears at a given place and time under given conditions. The audiogram may be used to describe the hearing of a person for the various frequencies tested. It may be used to calculate the amount of hearing handicap a person has. And, it may be used as a tool to determine the cause of a person’s hearing loss. Audiograms may be obtained in many ways; e.g., by using pure tones via air conduction or bone conduction for behavioral testing or by using tone pips to generate auditory brainstem responses. The audiogram is a most unusual biometric test. It is often incorrectly compared to a vision test. In the audiogram, the goal is to determine the lowest signal level a person can hear. In the case of a vision test, the person reads the smallest size of print that he or she can see, the auditory equivalent of identifying the least perceptible difference between two sounds. In most occupational and medical settings, this requires the listener to respond to very low levels of sounds that he or she does not hear in normal day-to-day life. A vision test analogous to an audiogram would require a person to sit in a totally darkened room and be tested for the lowest luminosity light of various colors, red to blue, that can be seen.
    [Show full text]
  • PUBLIC HEALTH CODE (EXCERPT) Act 368 of 1978 PART 168. AUDIOLOGY 333.16801 Definitions; Scope of Practice; Limitation
    PUBLIC HEALTH CODE (EXCERPT) Act 368 of 1978 PART 168. AUDIOLOGY 333.16801 Definitions; scope of practice; limitation. Sec. 16801. (1) As used in this part: (a) "Audiologist" means an individual licensed under this article to engage in the practice of audiology. (b) "Practice of audiology" means the nonmedical and nonsurgical application of principles, methods, and procedures related to disorders of hearing, including all of the following: (i) Facilitating the conservation of auditory system function. (ii) Developing and implementing hearing conservation programs. (iii) Preventing, identifying, and assessing hearing disorders of the peripheral and central auditory system. (iv) Selecting, fitting, and dispensing of amplification systems, including hearing aids and related devices, and providing training for their use. (v) Providing auditory training, consulting, education, and speech reading to individuals with hearing disorders. (vi) Administering and interpreting tests of vestibular function and tinnitus in compliance with section 16809 and in adherence to the mandate of subsection (2). (vii) Routine cerumen removal from the cartilaginous portion of the external ear in otherwise healthy ears except that if the audiologist, while engaged in routine cerumen removal, discovers any trauma, including, but not limited to, continuous uncontrolled bleeding, lacerations, or other traumatic injuries, he or she shall, as soon as practically possible, refer the patient to a person licensed in the practice of medicine or osteopathic medicine and surgery. (viii) Speech and language screening limited to a pass-fail determination for the purpose of identification of individuals with disorders of communication. (2) Practice of audiology does not include the practice of medicine or osteopathic medicine and surgery or medical diagnosis or treatment.
    [Show full text]
  • Occupational Noise Induced Hearing Loss and Audiometry
    2019 Occupational Noise Induced Hearing Loss and Audiometry ProfRAPID Ian Cameron REVIEW, Head John Walsh Centre for Rehabilitation Research The University of Sydney Kolling Institute of Medical Research [email protected] Dr Candice McBain, Research Assistant John Walsh Centre for Rehabilitation Research The University of Sydney Kolling Institute of Medical Research [email protected] Version 2 dated 25 June 2019 Summary Noise-induced hearing loss (NIHL) affects approximately five percent of the population worldwide (Zhou et al., 2013), making it a global public health concern. Occupational NIHL (ONIHL) occurs from continuous exposure to excessive noise, usually over a number of years. Continuous or intermittent noise in the work environment exceeding 85dB(A) during an eight-hour shift, or impact noise exceeding 120dB(A) during an eight hour working shift, is considered hazardous. Noise-induced hearing loss (HL) resulting from exposure to excessive occupational noise is a substantial health burden, and one of the most common chronic occupational diseases. In Australia, between July 2002 and June 2007, there were approximately 16,500 occupational NIHL workers compensation claims. Exposure to excessive noise can cause permanent damage to auditory structures; resulting in permanent threshold shifts that ultimately cause hearing damage. Noise induced hearing loss is a sensorineural (SNHL) hearing loss categorised by a high frequency 3-6 kHz notching audiometric pattern. Damage resulting from noise exposure usually begins at 3-6 kHz (Ali, Morgan, & Ali, 2014). However, with continued noise exposure, damage can spread to both lower (2, 1 kHz) and higher frequencies (8 kHz; Ali, (Morgan, & Ali, 2014).
    [Show full text]
  • Variation in Tone Presentation by Pure Tone Audiometers
    Abstract Manual pure tone audiometry has been in consistent use for a long period of time, and is considered to be the ‘gold standard’ for the assessment of hearing thresholds. Increasing legislative requirements, and a significant global cost impact of noise induced hearing loss, means that a significant amount of reliance is placed on this tool for diagnosis. There are a number of questions regarding the degree of accuracy of pure tone audiometry when undertaken in field conditions, particularly relating to the difference in conditions between laboratory and clinical environments. This study assessed the test-retest variability of a number of commercially available screening pure tone audiometers, all with recent calibration. Repeated clinical tests were made in accordance with ISO 8253-1:2010 of the hearing thresholds of 12 volunteers, including subjects with both normal and impaired hearing, and were compared with results from a previous study in which testing was undertaken in a laboratory setting using a Bruël and Kjaer Head and Torso simulator. The results of both laboratory and clinical studies showed a high level of test-retest variability, with maximum between test variation of up to 35 dB. Considerable variation occurred at all frequencies, with a particularly high level of variation at 6-8kHz. Levels of variation measured in this study suggests a high potential for diagnostic error when using screening pure tone audiometry, particularly in higher frequencies. Keywords: Audiometry, Calibration, Variance, Hearing Threshold, Audiometer 1. Introduction1 In the field of audiology, manually operated hearing assessment using pure tones according to ISO 8253- 1:2010 [1] is considered the ‘gold standard’ for the assessment of hearing thresholds by airborne conduction [2].
    [Show full text]
  • Demystifying Hearing Assistance Technology a Guide for Service Providers and Consumers
    Demystifying Hearing Assistance Technology A Guide for Service Providers and Consumers Cheryl D. Davis Samuel R. Atcherson Marni L. Johnson Davis, C.D., Atcherson, S.R., & Johnson, M.L. (2007). Demystifying Hearing Assistance Technology: A guide for service providers and consumers. Northridge, CA: PEPNet West, National Center on Deafness, California State University, Northridge Funded by U.S. Department of Education Office of Special Education and Rehabilitation Services Regional Centers on Postsecondary Education for Individuals Who are Deaf (H324A010001) Note: Versions of these chapters can also be found in the PEPNet publication Hard of Hearing Students in Postsecondary Settings: A guide for service providers on the PEPNet Resource Center Website at www.pepnet.org or http://prcorder.csun.edu/media/1219hh- students/index.html. This book is also available at www.wou.edu/~davisc. In addition to the technology information presented here, the publication includes information on demographics, transition, vocational rehabilitation, and disability services. Demystifying Hearing Assistance Technology A guide for service providers and consumers Cheryl D. Davis Samuel R. Atcherson Marni L. Johnson Table of Contents Introduction 1 I. Audiological Considerations in the Management of Hearing Loss 5 Characterizing Hearing Loss 6 Role of Hearing Health Care Professionals 16 Best Practices in the Evaluation of Hearing and Rehabilitation 19 Hearing Aids and Auditory Implantable Devices 25 Dave’s Sample Audiological Report 38 II. Communication Access Options: Hearing Assistance Technology 41 Defining Communication Access 42 Assistive Listening Devices 46 Speech-to-Text Accommodations 59 Alerting Devices 68 Telecommunications 73 Closing Thoughts on Communication Technology 87 Ill. References and Resources 91 References 92 Resources 96 Photo and Graphic Image Credits 106 1 Introduction The incidence of hearing loss is growing in the United States.
    [Show full text]
  • Understanding Audiometry Calibration in the Occupational Setting
    BACK TO BASICS PEER REVIEWED Back to basics – understanding audiometry calibration in the occupational setting Karen Michell MSc(Nurs) ABSTRACT RN, RM, OHNP, Faulty audiometry equipment will lead to an inaccurate test result being recorded. This paper SASOHN Education Representative provides the reader with information regarding the calibration of the equipment. Three different methods of calibration, namely electro-acoustic calibration, biological or subjective testing, and Steve Geier, daily listening checks, are described. South African standards relating to the testing environment, E-mail: steve@amtronix. co.za particularly with respect to mobile testing facilities, are explained. Finally, information regarding record keeping and indications of faulty calibration is given. Corresponding author: Karen Michell Key words: audiometry, calibration, quality, audiometrist E-mail: karen@cosafety. co.za INTRODUCTION TYPES OF CALIBRATION Audiometry testing is performed to determine an individu- There are three different methods of calibration that must al’s hearing threshold at a given point in time and in occu- be completed on a regular basis and at predetermined inter- pational health the relevance is to determine if and when vals. These are commonly referred to as electro-acoustic an employee may have hearing loss that is occupational in calibration, biological or subjective testing, and daily listening nature. The audiometry test is performed in varied settings checks.2 Table 1 provides a summary of the different calibra- which may infl uence the test results if these settings are not tions and checks as explained in SANS 8253-1.2 controlled. In addition equipment that is faulty will also lead to an inaccurate test result being recorded.
    [Show full text]
  • The Role of Tele-Audiology in Supporting Access to Care
    The Role of Tele-audiology in Supporting Access to Care EHDI Meeting April 16, 2013 Glendale, AZ Diane Behl, NCHAM Anne Marie Tharpe, Vanderbilt University Deborah Hayes, Children’s Hospital Colorado Vicki Hunting, Iowa EHDI program Role of Tele-audiology in EHDI • Increased access to diagnostic evaluations = reducing loss to follow up • Include interpreters and cultural brokers = Support culturally competent services • Provide remote hearing aid management, CI procedures = timely intervention Learning Community Purpose: Share, Expand, Create Organizational/political Interpersonal Technology nuts & bolts processes procedures Learning Community Members • California • Canada • Colorado • Iowa • Tennessee • Wisconsin • Utah Key Factors • Building partnerships, laying groundwork • Ensuring secure, high-quality service delivery • Family-centered services • Reimbursement • Resources Tele-Audiology in Guam Improving Access to Care from 7,000 Miles Away! Deborah Hayes, Ph.D. University of Colorado School of Medicine Children’s Hospital Colorado National EHDI Conference April 16, 2013 HAFA ADAI! GUAM: A FEW FACTS •U.S. Territory acquired in 1898 following the Spanish-American War •Native people are Chamorro from Asian Pacific region •Japanese occupation during World War II; re-captured by the U.S. in 1944 •U.S. military presence with Naval and Air Force Bases •Semi-tropical island about 30 miles x 8 miles in size •Civilian population of 170,000 •Birthrate for 3,300 infants/year “Fiber Optic Flower” on a Beachfront Tree Purpose of this Presentation
    [Show full text]
  • Hearing Conservation Programme
    HEARING CONSERVATION PROGRAMME SHEQ/OHS/PROCEDURE – 001 Compiled by: Jacobeth Ramailane Manager - Occupational Health Joe Ledile Tefu Approved by: General Manager - SHEQ HEARING CONSERVATION PROGRAMME 1. PURPOSE AND SCOPE To ensure effective control of the occupational noise exposure in line with applicable legal and other requirements, in order to prevent Noise Induced Hearing Loss (NIHL). Noise is one of the most prevalent occupational hazards and despite all that is known about noise and its effect on health, NIHL remains one of the most commonly reported occupational diseases. Noise has auditory and non–auditory effects on the human body which affect safety and productivity in the workplace. This document is applicable to all City Power employees, contractors and relevant stakeholders, who may be exposed to occupational noise at or above 85dB (A) noise rating limit (8-hour rating level). Control of the exposure shall be regarded as adequate, only if the exposure is below the noise rating limit, or if the exposure is at or above the noise rating limit but the reason has been identified and action is taken as soon as is reasonably practicable, by means other than the use of hearing protective equipment (PPE should be the last resort), to lower exposure so that it does not exceed the noise rating limit. 2. DEFINITIONS AND ABBREVIATIONS ANIA Approved Noise Inspection Authority. Attenuation A reduction in the magnitude of sound transmitted. A graph, chart or table indicating the hearing threshold levels of an Audiogram individual produced during an audiometric test. Audiometric testing A test done to measure a person’s hearing threshold.
    [Show full text]
  • Best Practices Best Practices Manual
    EHDI BBestest PPracticesractices Manual Introduction Purpose Each year, approximately 12,000 babies are born in the United States with permanent hearing loss. With two to three of every 1,000 newborns having a hearing loss, it is the most frequently occurring birth defect. Additionally, another two to three per 1,000 children will acquire a hearing loss after birth. Screening and assessment are very important, even for families who have no history of hearing problems. In fact, most babies born with hearing loss are born to parents with normal hearing. If identification does not happen until after six months of age, the child's language skills at age three will be far behind those of a child with normal hearing.1 Families look to physicians, audiologists, and other health care providers to learn more about screening, assessment, intervention and resources available for their child and family. The purpose of the Iowa EHDI Best Practices Manual is to advance the development of a comprehensive statewide early hearing detection and intervention (EHDI) system in Iowa. This manual will assist hospitals, birth centers, Area Education Agencies (AEAs), health care providers and private practice audiologists in developing programs and written protocols for newborn hearing screening, follow up and intervention. The manual is based upon best practices within early hearing detection and intervention programs and Iowa EHDI law and rules. The EHDI program would also like to take this opportunity to let you know we appreciate the work you do to assure infants and children with hearing loss are identified as early as possible and receive ongoing support.
    [Show full text]
  • Audiological Functions in Pregnancy 1Ashok Verma, 2Rakesh Thakur, 3Sunder S Dogra, 4Shivani Sharma, 5Amrita Singhal
    JSAFOG Ashok Verma et al 10.5005/jp-journals-10006-1455 RESEARCH ARTICLE Audiological Functions in Pregnancy 1Ashok Verma, 2Rakesh Thakur, 3Sunder S Dogra, 4Shivani Sharma, 5Amrita Singhal ABSTRACT INTRODUCTION Introduction: During pregnancy virtually every organ system The anatomical, physiological, and biochemical adap- undergoes anatomical and physiological changes that can alter tations to pregnancy are profound. During normal appreciably the criteria for diagnosis and treatment of diseases. Hormonal fluctuations alter the composition of endolymph and pregnancy, virtually every organ system undergoes perilymph, and ion transport process. Hence, audiological func- anatomical and physiological changes that can alter tions in pregnancy need evaluation. appreciably the criteria for diagnosis and treatment of Materials and methods: After approval of Institutional Ethics diseases. Without understanding of these adaptations Committee, 100 pregnant women were recruited in the 1st to pregnancy, it is almost impossible to understand the trimester. Tuning tests were done using 128, 256, 512, and disease process that can threaten during pregnancy. A 1024 Hz tuning forks. Pure tone audiometry was done and hearing thresholds measured for 125, 250, 500, 1000, 2000, number of physiological changes occur during preg- and 4000 Hz. Finally, impedance audiometry was done in all nancy; among them audiological changes are quite the women in each trimester. significant.1 Results: There was no air–bone gap. There was gradual reduc- These changes are mainly due to the changing levels tion in hearing acuity at low frequencies (125, 250, 500, and of sex hormones and return to normal once pregnancy is 1000 Hz) from 1st to 3rd trimester of pregnancy. The hearing over.
    [Show full text]