Meshes for Intraabdominal Placement (Laparoscopic)

Total Page:16

File Type:pdf, Size:1020Kb

Meshes for Intraabdominal Placement (Laparoscopic) V.- MESHES FOR INTRAABDOMINAL PLACEMENT (LAPAROSCOPIC) PICTURES NAME of the products Soft Tissue Patch MANUFACTURER Gore DESCRIPTION e-PTFE mesh for intraperitoneal placement For reconstruction of hernias or soft tissue deficiencies, surgeons require a prosthesis affording a secure repair with decreased risk of recurrence, increased patient comfort postoperatively, and minimal complications such as adhesions and fistula formation. The GORE-TEX® Soft Tissue Patch has long been the prosthetic patch of choice for soft tissue repairs. Composed of the inert biomaterial expanded polytetrafluoroethylene (ePTFE), it features a microporous structure allowing for host tissue incorporation. GORE-TEX® Soft Tissue Patch meets the unique challenges of laparoscopic hernia repair and inguinal herniorrhaphy, as well as temporary bridging of fascial defects. It is contraindicated for the reconstruction of cardiovascular and orthopedic defects. The GORE-TEX® Soft Tissue Patch has material and suture/staple retention strength greater than the most commonly used meshes. The biological inertness of the prosthesis, combined with softness and conformability in vivo, minimizes foreign-body response, erosion into the bowel, and adhesions to surrounding viscera. The GORE-TEX® Soft Tissue Patch offers ease of handling, including cutting and shaping to size without fraying. Pre-configured patches requiring little or no trimming before implantation are also provided. ADVANTAGES • Composed of the inert biomaterial expanded polytetrafluoroethylene (ePTFE), it features a microporous structure allowing for host tissue incorporation. • Unique challenges of laparoscopic hernia repair and inguinal herniorrhaphy • • http://www.goremedical.com/stp/ PICTURES NAME of the products Dual Mesh Biomaterial MANUFACTURER Gore DESCRIPTION e-PTFE mesh for intraperitoneal placement In certain hernia and soft tissue reconstructions, and in temporary bridging of fascial defects, it is sometimes necessary to encourage host tissue ingrowth along one surface, while minimizing tissue attachment along another surface. GORE® DUALMESH® Biomaterial is a soft, conformable, ePTFE materialthat offers a unique, two-surface design intended for such applications. The biomaterial features two functionally distinct surfaces: the textured CORDUROY Surface encourages host tissue incorporation while the smooth surface minimizes tissue attachment to the material. ADVANTAGES • Maximizing peritoneal ingrowth while minimizing visceral tissue attachment in hernia, soft tissue and fascial reconstruction • • http://www.goremedical.com/dualmesh/ • PICTURES NAME of the products Dual Mesh Plus MANUFACTURER Gore DESCRIPTION e-PTFE mesh for intraperitoneal placement GORE® DUALMESH® PLUS Biomaterial is the first two-surface hernia repair material with antimicrobial technology for controlling potential operative contamination of the material. This advanced ePTFE biomaterial contains two antimicrobial preservative agents, silver carbonate and chlorhexidine diacetate, which act to inhibit microbial colonization of, and resist initial biofilm formation on, the device for up to 14 days post-implantation. Using zone of inhibition bioassays, substantial preservative activity associated with the device has been demonstrated against laboratory strains and clinical isolates of the some organisms ADVANTAGES Maximizing peritoneal ingrowth while minimizing visceral tissue attachment in hernia, soft tissue and fascial reconstruction demonstrated against laboratory strains and clinical isolates of the following organisms: Methicillin resistant Staphylococcus aureus (MRSA), Vancomycin-resistant Enterococcus faecalis (VRE), Escherichia coli, Pseudomonas aeruginosa, Klebsiella pneumonia, Staphylococcus epidermidis, Candida albicans, Staphylococcus aureus, Group A Streptococcus, Acinetobacter baumannii • http://www.goremedical.com/dualmeshplus/ • PICTURES NAME of the products Dual Mesh Plus with holes MANUFACTURER Gore DESCRIPTION e-PTFE mesh for intraperitoneal placement GORE® DUALMESH® PLUS Biomaterial is also available with holes. These macropores encourage faster tissue incorporation, while maintaining the benefits of GORE® DUALMESH® Biomaterial. It also offers all the performance advantages of GORE® DUALMESH® Biomaterial, such as rapid host tissue incorporation and minimal foreign- body response. ADVANTAGES • encourage faster tissue incorporation, while maintaining the benefits of GORE® DUALMESH® Biomaterial • http://www.goremedical.com/dualmeshplus/ • PICTURES NAME of the products Omyra® Mesh MANUFACTURER B Braum DESCRIPTION c-PTFE mesh for intraperitoneal placement Omyra® Mesh brings a new concept for hernia repair within the antiadhesive mesh group. It is a film of condensed polytetrafluoroethylene (cPTFE) with very low density (0.9 g/cm3) and a macroporous star-shaped structure (2.4 mm). Omyra® Mesh is the first mesh in a monolayer, non-coated format which has antiadhesive and bacterial resistant properties. The cPTFE material improves the adhesion prevention features of the traditional expanded PTFE, whereas the star-macroporous structures enhance a fast tissue integration like the one achieved with polypropylene meshes. Furthermore, the transparent monolayer that Omyra® Mesh provides, offers excellent handling, especially in laparoscopic procedures. ADVANTAGES • Highly biocompatible with star pore structures • Macropores to allow an excellent tissue integration • Fast neo-peritoneum formation covering the mesh • Impairment of bacterial growth • Reduction of adhesion formation • Condensed PTFE • Transparent and tailorable ensuring an optimal handling • http://www.bbraun.com/cps/rde/xchg/bbraun- com/hs.xsl/9094.html PICTURES NAME of the products COMPOSIX™ EX Mesh MANUFACTURER Bard, Davol DESCRIPTION Heavy-weight polypropylene/ePTFE composite for laparoscopic repair of ventral and incisional hernias ADVANTAGES • Two distinctly different sides: Polypropylene BARD® Mesh on one side to promote tissue ingrowth and sub-micronic ePTFE on the other side to minimize adhesions to the prosthesis. • Elliptically shaped design: Reduces the need to trim the mesh, saving time. • Low Profile: Makes it ideally suited for laparoscopic ventral hernia repairs. • Sealed Edge: Prevents exposure of the polypropylene mesh side from contact with the bowel, thus potentially reducing the chances of adhesions around the edge of the prosthesis. http://www.davol.com/products/soft-tissue- reconstruction/hernia-repair/ventral-hernia- repair/laparoscopic-repair-options/composix- ex-mesh/ PICTURES NAME of the products COMPOSIX™ L/P Mesh MANUFACTURER Bard, Davol DESCRIPTION Light-weight, low profile polypropylene BARD® Soft Mesh specifically designed to meet the meticulous challenges of laparoscopic ventral hernia repair ADVANTAGES Made with lightweight, low profile • polypropylene BARD® Soft Mesh that is approximately 60% lighter than traditional polypropylene mesh. • Lightweight, large pore polypropylene matrix leaves less foreign body mass than traditional polypropylene mesh. • Easier handling and laparoscopic insertion – all sizes can fit through a trocar. • Optional Introducer Tool, which is packaged with larger sizes, makes insertion even easier. • Two distinctly different sides: polypropylene BARD® Soft Mesh on one side to promote tissue ingrowth and sub-micronic ePTFE on the other side to minimize tissue attachment to the prosthesis. • http://www.davol.com/products/soft-tissue- reconstruction/hernia-repair/ventral-hernia- repair/laparoscopic-repair-options/composix-lp- mesh/ PICTURES NAME of the products SEPRAMESH™ IP Composite MANUFACTURER Bard, Davol DESCRIPTION Davol is excited to offer an innovative mesh combined with a proven absorbable barrier to minimize tissue attachment to the mesh.The absorbable layer is built on a foundation of proven Sepra* technology, supported by 11 years of clinically demonstrated success. SEPRAMESH™IP Composite merges a polypropylene mesh with a hydrogel safety coating, resulting in a permeable repair. ADVANTAGES • Hydrogel barrier minimizes tissue attachment to the prosthesis. • Bioresorbable fibers reinforce mesh strength and bind the mesh to the hydrogel coating. • Deep tissue incorporation. • Easily cut to customize shape and size. • Ideal memory for laparoscopic repair. • Material choices – NO ORC (oxidized regenerated cellulose) and NO polyester. http://www.davol.com/products/soft-tissue- reconstruction/hernia-repair/ventral-hernia- repair/laparoscopic-repair-options/sepramesh- ip-composite/ PICTURES NAME of the products VENTRALIGHT™ ST Mesh MANUFACTURER Bard, Davol DESCRIPTION Proven Sepra® Technology in a Low Profile, Lightweight Mesh ADVANTAGES • Low profile design facilitates trocar deployment and mechanical fixation. Easily cut to customize shape and size. • • Uncoated lightweight monofilament polypropylene allows for complete tissue ingrowth with a low percentage of contraction* for a strong repair. • Hydrogel barrier minimizes tissue attachment to the visceral side of the mesh. • Hydrogel barrier is based on Sepra® Technology. • Lightweight monofilament polypropylene. • Both materials have been used in general surgery for years with demonstrated clinical success. http://www.davol.com/products/soft-tissue- reconstruction/hernia-repair/ventral-hernia- repair/laparoscopic-repair-options/ventralight- st-mesh/ PICTURES NAME of the products ECHO PS™ Positioning System with VENTRALIGHT™ ST and COMPOSIX™ L/P Mesh MANUFACTURER Bard, Davol DESCRIPTION The latest technology from Bard, the ECHO PS™ Positioning
Recommended publications
  • Stephen Tabiri
    Surgical Mesh should be available inguinal hernia repair in Low and Middle Income Countries Presenter: Stephen Tabiri 1University for Development Studies-School of Medicine and Health Sciences 2University of Utah Center for Global Surgery 3 Holy Family Hospital Declaration • Nothing to disclose ~ 5 billion Meara JM et al. Global surgery 2030: evidence and solutions for achieving health, welfare, and economic development. The Lancet 2010; 386 (9993); 569-624. Debas et al. Disease Control Priorities in Developing Countries. 2nd ed. Washington, DC: World Bank and Oxford University Press; 2006: 1245-1259. Intervention Cost per DALY averted (in $US) Inguinal hernia repair (Ghana) $14.66 Cataract surgery $50 Vitamin A supplementation $10 Oral rehydration solution $1000 Antiretroviral therapy for $900 HIV/AIDS Insecticide treated bednets $29 Shillcut et al., Cost-effectiveness of groin hernia surgery in the Western Region of Ghana. Archives of Surgery 2010; 145: 954. Chao et al., Cost-effectiveness of surgery and its policy implications for global health: a systematic review and analysis. Lancet Global Health 2014; 2: e334-e345. Traditional methods and results vs 1.4-7.9% 3.15%! Ohene-Yeboah M, Beard JH, Frimpong-Twumasi B, Koranteng A, Mensah S. Prevalence of inguinal hernia in adult men in the Ashanti Region of Ghana. World Journal of Surgery 2015; 40: 806-812. Beard J, Oresanya LB, Ohene-Yeboah M, Dicker R, Harris HW. Characterizing the global burden of surgical disease: a method to estimate inguinal hernia epidemiology in Ghana. World Journal of Surgery 2013; 37: 498. • Purpose: assess the current state of inguinal hernia repair in northern Ghana.
    [Show full text]
  • Regenerative Surgery for Inguinal Hernia Repair
    Clinical Research and Trials ` Research Article ISSN: 2059-0377 Regenerative surgery for inguinal hernia repair Valerio Di Nicola1,2* and Mauro Di Pietrantonio3 1West Sussex Hospitals NHS Foundation Trust, Worthing Hospital, BN112DH, UK 2Regenerative Surgery Unit, Villa Aurora Hospital-Foligno, Italy 3Clinic of Regenerative Surgery, Rome, Italy Abstract Inguinal hernia repair is the most frequently performed operation in General Surgery. Complications such as chronic inguinal pain (12%) and recurrence rate (11%) significantly influence the surgical results. The 4 main impacting factors affecting hernia repair results are: mesh material and integration biology; mesh fixation; tissue healing and regeneration and, the surgical technique. All these factors have been analysed in this article. Then a new procedure, L-PRF-Open Mesh Repair, has been introduced with the aim of improving both short and long term results. We are presenting in a case report the feasibility of the technique. Introduction Only 57% of all inguinal hernia recurrences occurred within 10 years after the hernia operation. Some of the remaining 43% of all Statistics show that the most common hernia site is inguinal (70- recurrences happened only much later, even after more than 50 years [7]. 75% cases) [1]. A further complication after inguinal hernia repair is chronic groin Hernia symptoms include local discomfort, numbness and pain pain lasting more than 3 months, occurring in 10-12% of all patients. which, sometimes can be severe and worsen during bowel straining, Approximately 1-6% of patients have severe chronic pain with long- urination and heavy lifting [2]. Occasionally, complications such as term disability, thus requiring treatment [5,8].
    [Show full text]
  • Surgical Mesh Repair of Inguinal Hernia in Men
    Plain Language Summary January 2020 Surgical mesh repair of inguinal hernia in men What is an inguinal hernia? An inguinal hernia is a type of groin hernia. Inguinal hernias occur when a piece of bowel or fatty tissue bulges out through the abdominal wall causing a swelling in the groin. Inguinal hernias are much more common in men than women: nine hernias in men to every one hernia in women. What is surgical mesh hernia repair? Operations to repair an inguinal hernia can either use a piece of surgical mesh to reinforce the body tissues or surgical stitches to pull the body’s tissues together. Surgical mesh is a loosely woven sheet of polypropylene (a type of plastic). The ‘thread’ used to stitch tissues together for hernia repair is also made of polypropylene. Why is this important? Use of surgical mesh has become an important topic in the last few years following women’s experiences of severe chronic pain after an operation using surgical mesh to treat pelvic organ prolapse. In Scotland there are around 5,000 inguinal hernia repairs each year that use surgical mesh. Following the issues raised about surgical mesh for pelvic organ prolapse, there is an awareness that similar issues need to be considered in relation to using surgical mesh for repair of inguinal hernias. What we did We assessed whether inguinal hernia repair using surgical mesh was effective, safe and good value for money. We also explored patient experiences and views about using surgical mesh for inguinal hernia repair. What we found Men who had an inguinal hernia repaired using surgical mesh were less likely to have their hernia return compared with men who had their hernia repaired using surgical stitches.
    [Show full text]
  • Insertion and Removal of Vaginal Mesh for Pelvic Organ Prolapse
    CLINICAL OBSTETRICS AND GYNECOLOGY Volume 53, Number 1, 99–114 r 2010, Lippincott Williams & Wilkins Insertion and Removal of Vaginal Mesh for Pelvic Organ Prolapse TYLER M. MUFFLY, MD and MATTHEW D. BARBER MD, MHS Department of Obstetrics and Gynecology, Center for Urogynecology and Pelvic Reconstructive Surgery, Obstetrics, Gynecology and Women’s Health Institute, Cleveland Clinic, Cleveland, Ohio Abstract: A variety of surgical meshes are available A woman’s risk of requiring surgery for to correct pelvic organ prolapse. This article discusses prolapse is approximately 7% by the age benefits and risks of vaginal mesh use. Emphasis is 1 placed on the appropriate surgical technique to im- of 80 years. Of those who receive surgery, prove outcomes and minimize mesh complications. an estimated 13% will require a repeat Placement options are reviewed with the discussion operation within 5 years and as many of self-tailored mesh, trocar-based mesh kits, and non- as 29% will undergo another surgery trocar mesh kits. This article also reviews the manage- for prolapse or a related condition at ment of mesh complications including the technique 1,2 for mesh removal. some point during their life. Given the Key words: pelvic organ prolapse, surgical mesh, mesh rates of prolapse recurrence after surgery, kits, mesh erosion many pelvic reconstructive surgeons have incorporated the use of synthetic or bio- logic graft materials into their repairs in an attempt to improve outcomes. The concept of using mesh or grafts to im- Introduction prove native tissue repairs is not novel. Pelvic organ prolapse is one of the most The use of synthetic mesh for inguinal and common indications for surgery in wo- ventral hernia repair is well supported men with approximately 200,000 inpati- in the general surgery literature and is ent surgical procedures performed for this currently considered the ‘‘gold standard’’ indication in the United States annually.1 approach.3 The use of synthetic mesh during sacral colpopexy to suspend the Correspondence: Matthew D.
    [Show full text]
  • TIGR® Matrix Surgical Mesh Launched in the United States
    ® SURGICAL MESH CORPORATE - timeline The history of Novus Scientic - a journey of innovation RadiPlast founded Radi Medical Systems AB founded. PressureWire® methodology ‘Fractional Flow Reserve’ (FFR) conceived. on the basis of using Novus Scientific founded. intelligent plastic Radi grows it’s international presence globally with nine regional offices. TIGR® mouldings to avoid RadiPlast becomes RadiPlast sold to to CR Bard. available injuries to children. agent for ACS (Advanced Employees around the world swell to 350. in EU. Catheter Systems). Radi acquired by St Jude Medical Inc. Later the company First PressureWire® sold. TIGR® turns its’ hand to available PressureWire® (Radi Sensor) First FemoStop® sold. First Femoseal® sold. selling catheter kits. in USA. concept conceived. Work starts on TIGR™ project. Polymer research starts in earnest at the Radi research facility in Uppsala. 03 011 1978 2004 1979 2005 1980 2006 RadiPlast 1981 MEDICAL SYSTEMS 2007 1982 2008 1983 2009 1984 1978 1985 Engstrom runs radiology product company 1986RadiPlast AB. 1987 1982 1988 Engstrom secures distribution rights to Advanced Cardiovascular 1989 Systems Inc. (ACS > Guidant Inc). 1990 1988 1991 Engstrom sells RadiPlast AB to CR Bard Inc. and founds Radi Medical Systems 1992 AB. 1993 1988 – 2008 1994 1995 Radi pioneers some of the world’s leading devices for interventional cardiology, hemostasis 1996 management, and radiology. 1999 1997 1998 Engstrom sets up a resorbable biomaterials R&D department in Sweden. 1999 2003 2000 2001 Engstrom invests heavily in clean room production facilities on the island of Phuket. 2002 2004 20 ® Resorbable polymer matrix project group established - 1st patent filed for what would become TIGR Matrix Surgical Mesh.
    [Show full text]
  • The Role of Mesh Implants in Surgical Treatment of Parastomal Hernia
    materials Review The Role of Mesh Implants in Surgical Treatment of Parastomal Hernia Karolina Turlakiewicz 1,2,* , Michał Puchalski 1 , Izabella Kruci ´nska 1 and Witold Sujka 2 1 Institute of Material Science of Textiles and Polymer Composites, Lodz University of Technology, Zeromskiego˙ 116, 90-924 Lodz, Poland; [email protected] (M.P.); [email protected] (I.K.) 2 Tricomed S.A., Swi˛etoja´nska5/9,´ 93-493 Lodz, Poland; [email protected] * Correspondence: [email protected] Abstract: A parastomal hernia is a common complication following stoma surgery. Due to the large number of hernial relapses and other complications, such as infections, adhesion to the intestines, or the formation of adhesions, the treatment of hernias is still a surgical challenge. The current standard for the preventive and causal treatment of parastomal hernias is to perform a procedure with the use of a mesh implant. Researchers are currently focusing on the analysis of many relevant options, including the type of mesh (synthetic, composite, or biological), the available surgical techniques (Sugarbaker’s, “keyhole”, or “sandwich”), the surgical approach used (open or laparoscopic), and the implant position (onlay, sublay, or intraperitoneal onlay mesh). Current surface modification methods and combinations of different materials are actively explored areas for the creation of biocompatible mesh implants with different properties on the visceral and parietal peritoneal side. It has been shown that placing the implant in the sublay and intraperitoneal onlay mesh positions and the use of a specially developed implant with a 3D structure are associated with a lower frequency of recurrences.
    [Show full text]
  • Surgical Mesh for Inguinal Hernia Repair
    Surgical mesh for inguinal hernia repair March 2019 Acknowledgements This report is authored by Elena Tumasz-Jordan, Liza Mastikhina, Brenlea Farkas, Diane Lorenzetti, Joyce Li, and Fiona Clement on behalf of the HTA Unit at the University of Calgary. The authors declare no conflict of interests. This research was supported by the Health Technology Assessment Office, Province of BC. The views expressed herein do not necessarily represent those of the Government of British Columbia. Table of Contents Abbreviations .................................................................................................................................. 9 Executive Summary ...................................................................................................................... 10 Purpose of this Health Technology Assessment ................................................................... 13 Research Question and Research Objectives ........................................................................ 13 Overview of Approach .......................................................................................................... 13 Background ........................................................................................................................... 14 4.1 Surgical Mesh ................................................................................................................. 14 4.1.1 Description of Mesh ................................................................................................ 14 4.1.2
    [Show full text]
  • Surgical Mesh for Transvaginal Repair of Pelvic Organ Prolapse in the Anterior Vaginal Compartment
    Surgical Mesh for Transvaginal Repair of Pelvic Organ Prolapse in the Anterior Vaginal Compartment FDA Executive Summary Obstetrics and Gynecology Devices Panel February 12, 2019 Table of Contents I. Introduction .......................................................................................................................................... 4 II. Clinical Background on Pelvic Organ Prolapse .................................................................................... 5 A. Overview of Condition ..................................................................................................................... 5 B. Prevalence ........................................................................................................................................ 7 C. Risk Factors ....................................................................................................................................... 8 D. Treatment ......................................................................................................................................... 8 E. Professional Society Positions ......................................................................................................... 8 F. Professional Society Guidelines Regarding Training ..................................................................... 10 III. Device Description .......................................................................................................................... 10 IV. Regulatory History .........................................................................................................................
    [Show full text]
  • Polymer Hernia Repair Materials: Adapting to Patient Needs and Surgical Techniques
    materials Review Polymer Hernia Repair Materials: Adapting to Patient Needs and Surgical Techniques Marta Rodríguez 1,2,3, Verónica Gómez-Gil 1,2 ,Bárbara Pérez-Köhler 2,3,4 , Gemma Pascual 2,3,4 and Juan Manuel Bellón 1,2,3,* 1 Departamento de Cirugía, Ciencias Médicas y Sociales, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, Alcalá de Henares, 28805 Madrid, Spain; [email protected] (M.R.); [email protected] (V.G.-G.) 2 Biomedical Networking Research Centre of Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), 28029 Madrid, España; [email protected] (B.P.-K.); [email protected] (G.P.) 3 Ramón y Cajal Health Research Institute (IRYCIS), Colmenar Viejo, 28034 Madrid, Spain 4 Departamento de Medicina y Especialidades Médicas, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, Alcalá de Henares, 28805 Madrid, Spain * Correspondence: [email protected] Abstract: Biomaterials and their applications are perhaps among the most dynamic areas of research within the field of biomedicine. Any advance in this topic translates to an improved quality of life for recipient patients. One application of a biomaterial is the repair of an abdominal wall defect whether congenital or acquired. In the great majority of cases requiring surgery, the defect takes the form of a hernia. Over the past few years, biomaterials designed with this purpose in mind have been gradually evolving in parallel with new developments in the different surgical techniques. In consequence, the classic polymer prosthetic materials have been the starting point for structural modifications or new prototypes that have always strived to accommodate patients’ needs.
    [Show full text]
  • Biocompatible Properties of Surgical Mesh Using an Animal Model
    Australian and New Zealand Journal of Obstetrics and Gynaecology 2006; 46: 42–45 Blackwell Publishing Asia Original Article Biocompatible properties of surgical mesh Biocompatible properties of surgical mesh using an animal model Hannah G. KRAUSE,1 Stuart J. GALLOWAY,2 Soo K. KHOO,3 Richard LOURIE2 and Judith T. W. GOH1 1Urogynaecology Unit, Gold Coast Hospital, Southport, 2Department of Anatomical Pathology, St Vincent’s Hospital, Melbourne, and 3Department of Gynaecology, Royal Brisbane Women’s Hospital, Brisbane, Australia Abstract Aim: To study the biocompatibility of surgical meshes for use in pelvic reconstructive surgery using an animal model. Methods: Eight different types of mesh: Atrium, Dexon, Gynemesh, IVS tape, Prolene, SPARC tape, TVT tape and Vypro II, were implanted into the abdominal walls of rats for 3 months’ duration. Explanted meshes were assessed, using light microscopy, for parameters of rejection and incorporation. Results: Type 1 (Atrium, Gynemesh, Prolene, SPARC and TVT) and type 3 (Vypro II, Dexon and IVS) meshes demonstrated different biocompatible properties. Inflammatory cellular response and fibrosis at the interface of mesh and host tissue was most marked with Vypro II and IVS. All type 1 meshes displayed similar cellular responses despite markedly different mesh architecture. Conclusions: The inflammatory response and fibrous reaction in the non-absorbable type 3 meshes tested (IVS and Vypro II) was more marked than the type 1 meshes. The increased inflammatory and fibrotic response may be because of the multifilamentous polypropylene components of these meshes. Material and filament composition of mesh is the main factor in determining cellular response. Key words: animal model, biocompatibility, monofilament, multifilament, surgical mesh.
    [Show full text]
  • Hernia Repair
    HERNIA REPAIR What is a Hernia? A hernia is a weakness or tear in the wall of the abdomen resulting in a bulge or tear. The inner lining of the abdomen pushes through the weakened area of the abdominal wall to form a small balloon-like sax. This can allow a loop of intestine or abdominal tissue to push into the sac. A hernia can cause severe pain and potentially serious problems that could require emergency surgery. Hernias may be acquired (caused by wear and tear over the years) or congenital (result from a weakness in the abdominal wall present since birth). Hernias can get worse and grow larger over time. A hernia does not go away over time, nor will it go away by itself. Men, women and children of all ages can have hernias. How do I know I have a hernia? • Common areas to develop a hernia are in the groin (inguinal), belly button (umbilical), the site of a previous operation (incisional), high in the thigh, just below the groin (femoral), and in the groin at the internal ring (indirect inguinal hernia). • Hernias can be on both sides of the groin (bilateral hernias) or may recur at the site of a previous hernia (recurrent hernia). • You may notice a bulge under the skin or feel pain when you lift heavy objects, cough, or strain during urination or bowel movements. You may notice pain during prolonged sitting or standing. • The pain can be sharp and sudden or a dull ache that worsens towards the end of the day.
    [Show full text]
  • Regulatory Warnings and Use of Surgical Mesh in Pelvic Organ
    Letters implementing strategies to promote more judicious use of CT. of pelvic organ prolapse and reported 1503 mesh-related Efforts by policy makers and medical-center leaders to re- events (5-fold increase) in the Manufacturer and User Device align incentives that promote the escalating use of CT remain Experience database from January 1, 2008, through Decem- a societal imperative. ber 31, 2010.2 We sought to determine the extent of use of vaginal mesh in pelvic organ prolapse after the most recent Frank S. Drescher, MD FDA warning and patterns of discontinuation of the use of Brenda E. Sirovich, MD, MS vaginal mesh in New York State. Author Affiliations: Outcomes Group, VA Medical Center, White River Junction, Methods | We used data from the New York Statewide Plan- Vermont (Drescher, Sirovich); Medicine, Geisel School of Medicine at ning and Research Cooperative System, which contains rec- Dartmouth, Hanover, New Hampshire (Drescher, Sirovich); Pulmonary and Critical Care Medicine, Veterans Affairs, White River Junction, Vermont ords of all surgical procedures done in the state. Patients un- (Drescher); The Dartmouth Institute for Health Policy and Clinical Practice, dergoing surgical procedures for pelvic organ prolapse with or Hanover, New Hampshire (Sirovich). without the use of mesh from January 1, 2011, to December 31, Corresponding Author: Frank S. Drescher, MD, Pulmonary and Critical Care 2013, were identified through previously described methods.3 Medicine, Veterans Affairs, 215 N Main St (111), White River Junction, VT 05009 ([email protected]). Patients with previous repairs of prolapse were excluded. The average annual hospital volume of prolapse repair surgery was Published Online: December 28, 2015.
    [Show full text]