Wiegand Interface Module

Total Page:16

File Type:pdf, Size:1020Kb

Wiegand Interface Module DMP.COM @DMPALARMS Wiegand Interface Module 734INT FEATURES ▸ Connect door lock, power and ▸ Provides two auxiliary ▸ Supports up to seven reader technology to add relay outputs for door prop different card formats in ▸ Operates on 12/24 VDC input access control to the DMP XTINT applications addition to the DMP card and XRINT Series™ panels format ▸ Built-in 10 Amp at 12/24 V Form C ▸ Keypad programmable zone (SPDT) door release relay ▸ XR150 supports eight doors bypass, card reader and relay ▸ Provides four programmable and XR550 supports 32 doors, action operations protection zones suitable ▸ Provide codeless entry plus expandable to 96 for burglary and access system arming and disarming ▸ Armed status output for applications using DMP access cards or ▸ Custom cards allow for 1-255 armed display at entry door credentials; or customizable for bits, max 40 bits for card ▸ High-quality terminal blocks other credentials number ▸ Built-in optional piezo alert for secure, long-lasting sounder connections ▸ 734INT connects using four-wire ▸ Works with proximity and keypad or AX-Bus™ smartcard/high security ▸ Connect motion detectors, ▸ Attractive high-strength mechanical switches or other plastic housing allows ▸ Fast door access via 10/100 ▸ Programmable door entry devices for a Request-to-Exit mounting on walls, electrical network, 868 MHz or data bus strike time allows for 1-250 (REX) feature boxes or inside metal seconds, 0 strike time for enclosures ▸ Connect proximity readers toggle action ▸ Remote sounder output for directly local annunciation 734INT MODULE MODULE DESCRIPTION CONTROL ACCESS TO SPECIFIC AREAS Specifications It supplies a Form C (SPDT) Door Users simply present their card to the reader Primary Power 8.5 VDC to 28.5 VDC Strike relay, built-in piezo with remote to arm or disarm the system or open doors Current Draw annunciation output, data to panel LED in those areas for which they are authorized. Standby 346 mA (Includes 200 mA reader) and a four-position terminal for connecting Alarm 348 mA (Includes 200 mA reader) external Wiegand format proximity ZONE 3 REQUEST-TO-EXIT Form C Relay 35 mA at 12/24 VDC smartcard/high security readers. Includes You can also connect a REX device, such as Zones 5 VDC, 2 mA max model 333 suppressor for eliminating a motion detector or a mechanical switch, Dimensions 5" W × 3" H × 1.3125" D transient spikes due to relay switching. to the module’s Zone 3 to provide REX Each module provides four programmable capability to the system. This allows for a Compatibility XTINT and XRINT Series Panels protection zones for a variety of burglary relay activation and bypass or bypass only and access control applications. of Zone 2 on the 734INT. Proximity Credentials For Relay Activation and Bypass 1306 Prox Patch™ PROGRAMMING OPTIONS After a user trips the REX device, the Form 1326 Proxcard® II Card You have flexibility to: Set door release C relay releases the door allowing the 1346 ProxKey® III Access Device activation time for REX; turn the built-in user to exit without setting off an alarm. 1351 ProxPass® piezo speaker on or off; read custom user At the end of the strike time, REX action 1386 IsoProx® II Card card numbers; identify relay action modes; is inhibited for three seconds to prevent PSC-1 Standard Light Proximity Card, 10 Pk and define custom Wiegand bits, site piggy-back access. PSC-1 Standard Light Proximity Card, 100 Pk code position, user code position, offline PSC-3 Proximity Key Ring Tag, 100 Pk For Bypass Only operation mode and more. PSK-3 Proximity Key Ring Tag, 10 Pk After a user trips the REX device, the user PSM-2P ISO Imageable Proximity Card, 10 Pk EASY ENTRY™ FEATURE can exit without setting off an alarm. DE2 MIFARE® DESFire® EV1 Smartcard When an access card or prox key is CMC-2 Conekt Bluetooth Mobile Credential presented to a reader, the reader transmits CREDENTIAL READER FLEXIBILITY CSK-2 MIFARE DESFire EV1 Keyfob the data to the module. The readers support virtually any 26-40 bit Wiegand output credential reader — from The module validates the user’s code against External Proximity Readers simple 125 kHz prox readers to 13.56 MHz panel programming and, if authorized, the PP-6005B ProxPoint® Plus Proximity Reader smartcards and biometric scanners to new panel activates the Form C door release MP-5365 MiniProx™ Proximity Reader Bluetooth virtual credentials. Configure the relay. It also arms or disarms, if programmed PR-5455 ProxPro® II Proximity Reader devices to meet the demanding requirements for those functions. MX-5375 MaxiProx® Proximity Reader of today’s access control market. P-300-H-A Cascade Prox Reader XR PANEL FUNCTIONALITY UPGRADE ANY EXISTING DMP SYSTEM P-500-H-A Alps Prox Reader Add a 734INT device to provide fully P-620-H-A Denali Prox Reader & Keypad Designed to allow easy upgrading, the featured access control integrated into P-640-H-A Patagonia Prox Reader & Keypad 734INT connects to existing DMP systems the intrusion detection system. DMP DELTA3 Contactless Smartcard Reader and makes use of current panel authority devices grant access into an area based DELTA5 Contactless Smartcard Reader levels and access restrictions. on schedule, authority, profile and other DELTA6.4 Contactless Smartcard Reader & Keypad programmable controls designed to KEYPAD/AX-BUS CONNECTION CSR-35P Conekt Bluetooth Reader allow you to tailor the system to meet the The simplicity of the 734INT is in the requirements of nearly any application. Ordering information installation. The module connects to the 734INT* Wiegand Interface Module four-wire keypad/AX-Bus at any point along XT PANEL FUNTIONALITY its wire run and requires an address setting International Certifications Add a 734INT module to the keypad bus through the onboard switch block. EN 50130-4:2011+A1:2014 EN 50130-5:2011 of an XTINT Series™ panel to provide basic EN 50131-1:2006+A1:2009 EN 50131-3:2009 access control by allowing authorized users SUPPORTS UP TO EIGHT DIFFERENT CARD FORMATS EN 60839-11-1:2013 EN 61000-3-2:2006+A1+A2 to open a door anytime their cards are For compatibility with what your EN 61000-3-3:2013 EN 61000-6-4:2007 presented to the reader. customers are using, the 734INT module allows you to customize up to seven *RoHS Compliant DOOR CONTACT ZONE BYPASS concurrent card formats in addition to If the module is releasing an electric strike the DMP card format, although you’re not 800-641-4282 | DMP.com or magnet on a protected door, a time required to have a DMP card format — you 2500 N. Partnership Blvd, Springfield, MO 65803 bypass can be provided. The bypass timer have the flexibility to use all eight. Designed, engineered & manufactured in Springfield, MO is programmable, allowing users from 20 to using U.S. & global components 250 seconds to exit through the protected door without setting off an alarm. If the LIMITED WARRANTY: DMP warrants that the products door is open at the end of the bypass timer, manufactured by DMP and described herein shall be free a fault generates on Zone 2 on the 734INT. from defects of manufacture, labeling, and packaging for a period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the defective products are returned to DMP for inspection…To read the full DMP Limited Warranty, go to DMP.com/Warranty or check the DMP Price List or Catalog. © 2019 Digital Monitoring Products, Inc. | LT-0344INT | 19373.
Recommended publications
  • 734 Wiegand Interface Modules: Level C INSTALLATION and PROGRAMMING GUIDE
    734 Wiegand Interface Modules: Level C INSTALLATION AND PROGRAMMING GUIDE TABLE OF CONTENTS About the 734 ............................................. 1 Program the 734 ....................................... 17 Power Supply ......................................................... 1 Program Start Display ......................................17 Zone Terminals ...................................................... 1 Initialization Option ...........................................17 Annunciators .......................................................... 1 Initialize Confirm Option .................................18 Indicator LEDs ....................................................... 1 Activate Zone 2 Bypass ...................................19 Form C Relay ......................................................... 2 Zone 2 Bypass Time .........................................20 Programming Connection ................................ 2 Relock on Zone 2 Change ..............................20 Keypad In and Out Connections ................... 2 Activate Zone 3 Request to Exit ..................21 Zone 3 REX Strike Time ..................................22 PCB Features ...............................................3 Activate Onboard Speaker ............................22 Install the 734 .............................................4 Custom Card Definitions .........................23 Mount the 734 ...................................................... 4 Card Options .......................................................23 Wire the Electronic
    [Show full text]
  • Alarm Lock Catalog (ALA112U)
    Wireless & standalone access control door solutions trusted by more schools & universities, offices, retail chains & healthcare providers table of contents TRILOGY T2/ DL2700 STANDALONE DIGITAL PIN CODE LOCKS, CYLINDRICAL, DUAL-SIDED, MORTISE & EXIT DOORS . 2 TRILOGY CLASSROOM LOCKDOWN DL2700LD . 2 TRILOGY AUDIT TRAIL/PC-PROGRAMMABLE PUSHBUTTON LOCKS . 3 TRILOGY PROX LOCKS WITH HID PROX ID CARD READERS . 4 TRILOGY DOUBLE-SIDED PIN CODE AND PIN/PROX STANDALONE LOCKS . 5 TRILOGY STANDALONE LOCKS FOR PRIVACY AND SPECIAL APPLICATIONS . 6 TRILOGY HIGH SECURITY STANDALONE MORTISE LOCKS . 7 TRILOGY EXIT ADDS AUDIT TRAIL AND AUTO LOCK/UNLOCK TO PANIC EXITS . 8 TRILOGY NARROW STILE TRIM FOR ALL GLASS/ALUMINUM DOORS AND PANIC EXIT DOORS . 9-10 MATCHING TRILOGY DIGITAL PIN & PROX ACCESS 12/24V KEYPADS WITH AUDIT TRAIL . 10 TRILOGY AUDIT TRAIL AND PROGRAMMING ACCESSORIES, FINISHES AND ORDERING INFORMATION . .. 11 WIRELESS NETWORX KEYPADS & NETPANEL . 12-13 TRILOGY NETWORX WIRELESS 802 .11/ETHERNET LOCK ACCESS SYSTEMS . 14-17 ILOCK APP . 17 ARCHITECH DESIGNER WIRELESS ACCESS CONTROL LOCKING PLATFORM . 18-21 SIRENLOCK EXIT ALARMS: WATERPROOF, INTERIOR, AND DELAYED EGRESS . 22 REMOTE RELEASE MAG LOCKS, POWERMAGS AND RTES . 23 ADVANCED DOOR ALARMS . 24 ESSENTIAL ADD-ONS AND EXTRAS . 25 TRILOGY FAMILY OF ACCESS PRODUCTS CHART . 26-27 K-12 AND CAMPUS LOCDOWN SOLUTIONS . 28 ABOUT US, RETAIL LOCKSMITHS PROFIT CENTER PROGRAM AND TRAINING . 29 Trilogy: The leading electronic access locks ® Trilogy: hospital retail airport schools pharmacy office Retrofit Any
    [Show full text]
  • (Wiegand Interface) NDK-2025 Reader with Integrated
    Installation Sheet (Wiegand Interface) NDK-2025 Reader with Integrated Keypad Reader Description The NDK-2025 Reader is a radio-frequency proximity reader with integrated keypad for Access Control Systems. The Reader consists of a 12-key PIN pad, transmit/receive antenna, and reader electronics, in a durable metal housing. The reader and keypad electronics are potted with urethane resin to protect against the environment. The NDK-2025 Reader may be mounted like a cover plate on a single-gang electrical utility box, or on any surface. Parts List (a) Installation Sheet (b) Sentinel-Prox NDK-2025 Reader Installation Procedure 1. Install a single-gang electrical utility box, or drill two no. 27 (0.144 inch) clearance holes for the reader’s screws and one hole for the cable, at the desired location. Observe ADA height requirements. 2. Clip off the white 10-pin in-line connector from the end of the reader’s cable. Keep the wires as long as possible. 3. Remove reader’s back plate, and install it on an electrical utility box or other surface. The supplied screws can be used to fasten the back plate to a utility box (item c in the Parts List). 4. Connect the reader’s cable to the access control panel as shown in Figure 1. Connect the yellow wire only if used for Beeper control by the panel. In steps 8 and 9, let the yellow wire float. Do not connect the orange and violet wires to anything. Tape or cap all unused wires singly. 5. For red and black wires, use a linear regulated DC power supply, between 5V and 12V.
    [Show full text]
  • Xceedid OEM 100 User Guide
    OEM 100 User Manual Figure 1: OEM 100 Module with HG Rectangular Antenna Board Revision History Revision History Release Version Date Revision Description Authors Version 1.0 07/20/09 Initial Release Bryan Hoff and Jeremy Morton Version 1.1 07/30/10 Feature updates Bryan Hoff Version 1.2 08/05/10 Overhaul of document Bryan Hoff Version 1.3 08/17/10 Updated graphics Bryan Hoff Version 1.5 09/01/10 Applied XceedID branding Marian Sasso Contents Revision History ...................................................................................................................................................... 2 General Description ................................................................................................................................................ 3 Specifications .......................................................................................................................................................... 4 Physical Dimensions........................................................................................................................................... 4 Electrical Specifications ...................................................................................................................................... 4 Card Specifications ...................................................................................................................................... 5 Card Technologies Supported .....................................................................................................................
    [Show full text]
  • Frequently Asked Questions Readers & Credentials
    Frequently Asked Questions Readers & Credentials Contents: Reader Questions | Credential Questions | Other Questions | Glossary | Acronyms READERS: CREDENTIALS: Why choose smart card technology over What is a credential? proximity? What is a proximity card? What is the difference between proximity What is a contactless smart card? and contactless smart card/reader Why is it smart? technologies? What type of information can I keep on my What is the best way to migrate or transition smart card? from old proximity card technology to newer Why choose smart card technology over contactless smart technology? proximity? What does Multi-Technology mean when Why select smart credentials from Ingersoll referring to a reader? Rand Security Technologies? What are the benefits of multi-technology How does contactless smart card technology readers? compare in price to traditional proximity What are the benefits of aptiQ™ Readers? systems? What technology does aptiQ Can my access control system support smart utilize/support? cards? Why was MIFARE DESFire™ EV1 created Does Ingersoll Rand Security Technologies after MIFARE®? offer proximity cards compatible with HID® What readers are the aptiQ™ smart cards technology? using MIFARE DESFire™ EV1 compatible Will I be able to use one aptiQ™ card to with? perform more than one application such as What is iCLASS®? access control, food service payment, and What is aptiQ™? cashless vending? What is the difference between ISO 14443 I have heard for several years that “smart certification and ISO 15693? card” technology
    [Show full text]
  • Contactless Smart Card 13.56 Mhz High Frequency Technology
    A SMART CARD ALLIANCE ACCESS CONTROL COUNCIL RESOURCE Access Control Reader and Credential Architecture and Engineering Specification: Contactless Smart Card 13.56 MHz High Frequency Technology Version Number: 1.0 Publication Date: April 2015 Publication Number: ACC-15001 Smart Card Alliance 191 Clarksville Rd. Princeton Junction, NJ 08550 www.smartcardalliance.org About the Smart Card Alliance The Smart Card Alliance is a not-for-profit, multi-industry association working to stimulate the understanding, adoption, use and widespread application of smart card technology. Through specific projects such as education programs, market research, advocacy, industry relations and open forums, the Alliance keeps its members connected to industry leaders and innovative thought. The Alliance is the single industry voice for smart cards, leading industry discussion on the impact and value of smart cards in the U.S. and Latin America. For more information please visit http://www.smartcardalliance.org. Disclaimer: The Smart Card Alliance has used best efforts to ensure, but cannot guarantee, that the information described in this report is accurate as of the publication date. The Smart Card Alliance disclaims all warranties as to the accuracy, completeness or adequacy of information in this report. This publication does not endorse any specific product or service. Product or service references are provided to illustrate the points being made. Smart Card Alliance 2 Access Control Reader and Credential A & E Specification: Annotated Version [Insert Project Name] Specification for Architects, Consultants, and Engineers Access Control A&E Specification ___[insert date]___ Contactless Smart Card 13.56 MHz High Frequency Technology [Sample] A & E Guide Specification for Architects, Consultants, and Specifying Engineers This document contains sample guide specifications for 13.56 MHz contactless smart card technology products.
    [Show full text]
  • ACCESS CONTROL System
    New Catalog TDOP90 TDOP90 Hydra Varco | Mini Pulsar | TDOP90 | Mtes ACCESS CONTROL System Technology Magnetic Proximity Biometric Face Recognition ACCESS CONTROL System ACCESS CONTROL Solution For passage protection and access control for all the protected areas TELEDATA has an innovative series of products that base the functioning on biometric, magnetic and proximity cards recognizing systems. These systems, available in different frequency modulations and with combined functionality that can interface with other systems, allow to realize stand alone, centralized or integrated systems with a huge number of users. It is also possible to manage vehicular passages for protected areas with a recognizing system with a proximity transponder o using a number plate reader. ACCESS CONTROL System INDEX Intergated access control terminals ...................................................7 Vehicle card readers................................................................................ 18 Centralizable terminals .......................................................................... 10 Proximity keys ........................................................................................... 18 Stand alone terminals ............................................................................ 12 Fitband.......................................................................................................... 18 Magnetic card reader Clock and data .............................................. 12 Card programmes and printers ..........................................................
    [Show full text]
  • Security Considerations for Embedded System Rfid Readers
    This article was published in September 6, 2020 Issue of RFID Journal SECURITY CONSIDERATIONS FOR EMBEDDED SYSTEM RFID READERS By Kiran Vasishta, ELATEC, Inc. This article is the third in a series on considerations for embedded system RFID readers for embedded engineers, solution architects and product managers. In recent years, multinational corporations such as Cathay Pacific, Facebook, Uber and numerous others have been heavily fined due to security and data protection violations. This period has seen data protection laws increase as more and more information is gathered and shared online. As such, it becomes crucial to account for security capabilities when choosing an embedded device that touches potentially sensitive data. RFID readers very much belong to the ecosystem and any database or cloud server. While accounting wherein personal or user identification data is for security across a system is needed it is more transmitted either to a host system such as a PC or to important to consider the application or use case an endpoint such as a Human Machine Interface (HMI). that is in question. One should carefully evaluate the A passive RFID transponder, soft credential such as a consequences of any security breaches and if there is mobile phone app using BLE/NFC or smart cards and any sensitive information being exchanged from the other contact-based credentials all can carry sensitive RFID media to the host. As an example, the simple data or personal information. In the case of smart card choice of RFID media may directly lead to a compromise or contact-based credentials, the storage of personal in your intended application’s security.
    [Show full text]
  • Section 8 Access Control Systems
    8 Access Control Systems Section 8 Access Control Systems Belden . .8.1–8.11 Generic. .8.12–8.15 S2 Security Corporation. .8.16–8.19 HID Global . .8.20–8.29 Bosch Security Systems, Inc. .8.30–8.36 Schlage Electronic Security . .8.37–8.43 Von Duprin . .8.44 Schlage Recognition Systems. .8.45–8.46 Aiphone . .8.47–8.53 GE Security . .8.54–8.55 infinias. .8.56–8.59 D EasyLobby. .8.60 L-1 Enterprise Access Solutions. .8.61–8.64 Talk-A-Phone. .8.65–8.66 Access Control Systems Viking Electronics . .8.67–8.73 HES. .8.74–8.75 Securitron. .8.76–8.84 Access Control Systems Belden ./ Cables;Access Control/3586 Index1.Networking Systems//Video Products//Video Security Systems Multiconductor Shielded Plenum/Access Control Cables BELDEN PR22400V2-131675.eps Power limited circuit and communications cable for plenum applications. For use in remote control, signaling, security systems, communications, intercom/P.A. systems, sound/audio and nurse call. SPECIFICATIONS 1. CONDUCTOR: Solid or stranded bare copper 2. INSULATION: Flamarrest 3. SHIELD: Beldfoil shield applied overall with a drain wire 4. JACKET: Natural Flamarrest with ripcord 5. STANDARDS: NEC CMP or CL2P (CMP: 22-16 AWG), (CL2P: 14-12 AWG) 6. TEMPERATURE: 75 °C Conductor Conductor No. of Insulation Jacket Nominal Approx. Wt. Anixter No. Vendor No. Size AWG Strand Conductors Thickness (in.) Thickness (in.) O.D. (in.) lb./1,000 ft. B6000FE 6000FE 8771000 12 19 x 25 2 0.011 0.015 0.260 68 B6100FE 6100FE 8775000 14 19 x 27 2 0.011 0.015 0.220 51 B6101FE 6101FE 8771000 14 19 x 27 3 0.011 0.015 0.234
    [Show full text]
  • ATS1190 Smart Card Reader
    ATS1190 Smart Card Reader Programming Manual Version 2.0 Aritech and Tecom are Interlogix Companies © 2001 Interlogix B.V.. All rights reserved. Interlogix B.V. grant the right to reprint this manual for internal use only. Interlogix B.V. reserves the right to change information without notice. CONTENTS 1. Introduction............................................................................................................................................ 2 2. Configuring the Smart Card Reader .................................................................................................... 3 2.1. Programming information in the Smart Card Reader.................................................................... 3 2.2. Setting the reader’s address.......................................................................................................... 5 2.3. Changing the LED on-line settings................................................................................................ 7 2.4. Changing the LED off-line operation ............................................................................................. 9 2.5. Setting Valid Card (LED) Flash ................................................................................................... 10 2.6. Enabling the night light ................................................................................................................ 11 2.7. Setting the Protocol options........................................................................................................
    [Show full text]
  • (12) United States Patent (10) Patent No.: US 7,748,636 B2 Finn (45) Date of Patent: Jul
    USOO77486.36B2 (12) United States Patent (10) Patent No.: US 7,748,636 B2 Finn (45) Date of Patent: Jul. 6, 2010 (54) PORTABLE IDENTITY CARD READER (56) References Cited SYSTEM FORPHYSICAL AND LOGICAL U.S. PATENT DOCUMENTS ACCESS 4.014.602 A 3, 1977 Ruell (75) Inventor: David Finn, Tourmakeady (IE) 4,367.965 A 1/1983 Speitel et al. 4,897,644 A 1/1990 Hirano (73) Assignee: DPD Patent Trust Ltd., Lower 5,034,648 A 7/1991 Gastgeb Churchfield, Touma Ready, Co. Mayo 5,084,699 A 1/1992 DeMichele 5,376,778 A 12, 1994 Kreft (IE) 5,399,847 A 3, 1995 Droz 5,696,363 A 12/1997 Larchevesque (*) Notice: Subject to any disclaimer, the term of this 5,741,392 A 4, 1998 Droz patent is extended or adjusted under 35 5,761,648 A 6/1998 Golden et al. U.S.C. 154(b) by 497 days. 6,067.235 A 5, 2000 Finn et al. (21) Appl. No.: 11/779,299 (Continued) Filed: Jul.18, 2007 (22) FOREIGN PATENT DOCUMENTS (65) Prior Publication Data CA 227917.6 7, 1998 US 2008/OO 14867 A1 Jan. 17, 2008 Related U.S. Application Data (Continued) (63) Continuation-in-part of application No. 1 1/420,747, OTHER PUBLICATIONS filed on May 27, 2006, now Pat. No. 7,597,250, and a ACR38CT Contactless SIM Tracker Technical Specification, continuation-in-part of application No. 1 1/355.264, Advanced Card Systems Ltd., Hong Kong. filed on Feb. 15, 2006, and a continuation-in-part of application No.
    [Show full text]
  • QUICK START GUIDE 125-Khz PROXIMITY CARD READERS
    QUICK START GUIDE 125-kHz PROXIMITY CARD READERS This Quick Start Guide is intended for experienced installing technicians. It is a basic reference to ensure all connections are properly made. Models include P-300, P-500, P-530, P-620, P-640, P-710, P-900, P-403, P-405, P-410, P-453, P-455, as well as variants supporting most industry leading card and tag technologies. For additional information please reference Farpointe Data’s website, www.farpointedata.com. 1.0 Introduction 4.0 Cable Requirements A key component of a physical security electronic access control 24 AWG minimum, multi-conductor stranded with an overall foil shield, system, a proximity card reader is based on RFID technology. In for example Belden 9535 or similar, supporting the five conductors operation it is capable of reading data stored on a proximity credential comprising the physical layer of the Wiegand interface (power, ground, via radio frequency and without physical contact, and then passing the data 0, data 1, and/or beeper and LED). Alternatively, Belden 9539 or data obtained to the physical access control system. Access control similar, for all reader functions. Contact your access control system systems typically manage and record the movement of individuals manufacturer for their specific requirements. Per the SIA’s Wiegand through a protected area, such as a locked door. specification, maximum cable length is 500 feet (152 m). 2.0 Mounting Provisions 5.0 Output Formats Each reader may be installed either indoors or outdoors. Mounting Wiegand (industry standard 26-bit Wiegand and options shown in the table below.
    [Show full text]