Wiegand Interface Module
Total Page:16
File Type:pdf, Size:1020Kb
DMP.COM @DMPALARMS Wiegand Interface Module 734INT FEATURES ▸ Connect door lock, power and ▸ Provides two auxiliary ▸ Supports up to seven reader technology to add relay outputs for door prop different card formats in ▸ Operates on 12/24 VDC input access control to the DMP XTINT applications addition to the DMP card and XRINT Series™ panels format ▸ Built-in 10 Amp at 12/24 V Form C ▸ Keypad programmable zone (SPDT) door release relay ▸ XR150 supports eight doors bypass, card reader and relay ▸ Provides four programmable and XR550 supports 32 doors, action operations protection zones suitable ▸ Provide codeless entry plus expandable to 96 for burglary and access system arming and disarming ▸ Armed status output for applications using DMP access cards or ▸ Custom cards allow for 1-255 armed display at entry door credentials; or customizable for bits, max 40 bits for card ▸ High-quality terminal blocks other credentials number ▸ Built-in optional piezo alert for secure, long-lasting sounder connections ▸ 734INT connects using four-wire ▸ Works with proximity and keypad or AX-Bus™ smartcard/high security ▸ Connect motion detectors, ▸ Attractive high-strength mechanical switches or other plastic housing allows ▸ Fast door access via 10/100 ▸ Programmable door entry devices for a Request-to-Exit mounting on walls, electrical network, 868 MHz or data bus strike time allows for 1-250 (REX) feature boxes or inside metal seconds, 0 strike time for enclosures ▸ Connect proximity readers toggle action ▸ Remote sounder output for directly local annunciation 734INT MODULE MODULE DESCRIPTION CONTROL ACCESS TO SPECIFIC AREAS Specifications It supplies a Form C (SPDT) Door Users simply present their card to the reader Primary Power 8.5 VDC to 28.5 VDC Strike relay, built-in piezo with remote to arm or disarm the system or open doors Current Draw annunciation output, data to panel LED in those areas for which they are authorized. Standby 346 mA (Includes 200 mA reader) and a four-position terminal for connecting Alarm 348 mA (Includes 200 mA reader) external Wiegand format proximity ZONE 3 REQUEST-TO-EXIT Form C Relay 35 mA at 12/24 VDC smartcard/high security readers. Includes You can also connect a REX device, such as Zones 5 VDC, 2 mA max model 333 suppressor for eliminating a motion detector or a mechanical switch, Dimensions 5" W × 3" H × 1.3125" D transient spikes due to relay switching. to the module’s Zone 3 to provide REX Each module provides four programmable capability to the system. This allows for a Compatibility XTINT and XRINT Series Panels protection zones for a variety of burglary relay activation and bypass or bypass only and access control applications. of Zone 2 on the 734INT. Proximity Credentials For Relay Activation and Bypass 1306 Prox Patch™ PROGRAMMING OPTIONS After a user trips the REX device, the Form 1326 Proxcard® II Card You have flexibility to: Set door release C relay releases the door allowing the 1346 ProxKey® III Access Device activation time for REX; turn the built-in user to exit without setting off an alarm. 1351 ProxPass® piezo speaker on or off; read custom user At the end of the strike time, REX action 1386 IsoProx® II Card card numbers; identify relay action modes; is inhibited for three seconds to prevent PSC-1 Standard Light Proximity Card, 10 Pk and define custom Wiegand bits, site piggy-back access. PSC-1 Standard Light Proximity Card, 100 Pk code position, user code position, offline PSC-3 Proximity Key Ring Tag, 100 Pk For Bypass Only operation mode and more. PSK-3 Proximity Key Ring Tag, 10 Pk After a user trips the REX device, the user PSM-2P ISO Imageable Proximity Card, 10 Pk EASY ENTRY™ FEATURE can exit without setting off an alarm. DE2 MIFARE® DESFire® EV1 Smartcard When an access card or prox key is CMC-2 Conekt Bluetooth Mobile Credential presented to a reader, the reader transmits CREDENTIAL READER FLEXIBILITY CSK-2 MIFARE DESFire EV1 Keyfob the data to the module. The readers support virtually any 26-40 bit Wiegand output credential reader — from The module validates the user’s code against External Proximity Readers simple 125 kHz prox readers to 13.56 MHz panel programming and, if authorized, the PP-6005B ProxPoint® Plus Proximity Reader smartcards and biometric scanners to new panel activates the Form C door release MP-5365 MiniProx™ Proximity Reader Bluetooth virtual credentials. Configure the relay. It also arms or disarms, if programmed PR-5455 ProxPro® II Proximity Reader devices to meet the demanding requirements for those functions. MX-5375 MaxiProx® Proximity Reader of today’s access control market. P-300-H-A Cascade Prox Reader XR PANEL FUNCTIONALITY UPGRADE ANY EXISTING DMP SYSTEM P-500-H-A Alps Prox Reader Add a 734INT device to provide fully P-620-H-A Denali Prox Reader & Keypad Designed to allow easy upgrading, the featured access control integrated into P-640-H-A Patagonia Prox Reader & Keypad 734INT connects to existing DMP systems the intrusion detection system. DMP DELTA3 Contactless Smartcard Reader and makes use of current panel authority devices grant access into an area based DELTA5 Contactless Smartcard Reader levels and access restrictions. on schedule, authority, profile and other DELTA6.4 Contactless Smartcard Reader & Keypad programmable controls designed to KEYPAD/AX-BUS CONNECTION CSR-35P Conekt Bluetooth Reader allow you to tailor the system to meet the The simplicity of the 734INT is in the requirements of nearly any application. Ordering information installation. The module connects to the 734INT* Wiegand Interface Module four-wire keypad/AX-Bus at any point along XT PANEL FUNTIONALITY its wire run and requires an address setting International Certifications Add a 734INT module to the keypad bus through the onboard switch block. EN 50130-4:2011+A1:2014 EN 50130-5:2011 of an XTINT Series™ panel to provide basic EN 50131-1:2006+A1:2009 EN 50131-3:2009 access control by allowing authorized users SUPPORTS UP TO EIGHT DIFFERENT CARD FORMATS EN 60839-11-1:2013 EN 61000-3-2:2006+A1+A2 to open a door anytime their cards are For compatibility with what your EN 61000-3-3:2013 EN 61000-6-4:2007 presented to the reader. customers are using, the 734INT module allows you to customize up to seven *RoHS Compliant DOOR CONTACT ZONE BYPASS concurrent card formats in addition to If the module is releasing an electric strike the DMP card format, although you’re not 800-641-4282 | DMP.com or magnet on a protected door, a time required to have a DMP card format — you 2500 N. Partnership Blvd, Springfield, MO 65803 bypass can be provided. The bypass timer have the flexibility to use all eight. Designed, engineered & manufactured in Springfield, MO is programmable, allowing users from 20 to using U.S. & global components 250 seconds to exit through the protected door without setting off an alarm. If the LIMITED WARRANTY: DMP warrants that the products door is open at the end of the bypass timer, manufactured by DMP and described herein shall be free a fault generates on Zone 2 on the 734INT. from defects of manufacture, labeling, and packaging for a period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the defective products are returned to DMP for inspection…To read the full DMP Limited Warranty, go to DMP.com/Warranty or check the DMP Price List or Catalog. © 2019 Digital Monitoring Products, Inc. | LT-0344INT | 19373.