Grant Vortex Diesel Boilers with Underfloor Heating

Total Page:16

File Type:pdf, Size:1020Kb

Grant Vortex Diesel Boilers with Underfloor Heating How it works Protank with Valve Set Ask about other Heatmiser Neostat thermostat Comfortplus options Grant Vortex diesel condensing boilers that may work for you. Caleffi Composite Mixing Panel Central heating via underfl oor or radiators share the same high level of comfort but each method has unique characteristics which suit some applications better than others. Sometimes the best choice will be infl uenced by the lowest cost fuel options available at your location. RBM Kilma fl ex Radiator Heating underfl oor pipe Radiators emit warmth via a combination of natural convection and radiant heat. They off er the lowest running cost, are suitable for renovation or new build and suit concrete or timber fl oor construction. Heat Pump Major component warranty Air to water heat pumps are quiet, powerful, energy-effi cient and environmentally friendly. They harvest free energy found in the air outside the building envelope to power underfl oor heating and cooling systems. If comparing, consider the origin and guarantee off ered on key components Typical running cost: 0.08c/kWh and if warranty terms include labour. • Grant Vortex | 5 years parts and labour | Made in Ireland Gas Boiler • RBM Underfl oor pipe | Warranty 25 years | Manifolds | 5 years parts and labour | Made in Italy Gas boilers are the most cost eff ective option in terms of both • Protank Hot water cylinder | 20 years limited | Made in England installation and running costs. They are ultra effi cient, compact and almost silent when in use. Typical running cost: NG = 0.07c/kWh, LPG = 0.18c/kWh Dollars and sense Costs will vary depending on perceived comfort levels, insulation levels, ambient temperature extremes, building design/construction and regional energy prices. Below shows the estimated installation and running costs for a new 200m2 home based on 0ºC outside / 20ºC inside temperature. Our friendly tech team will design a system specifi cally for you and your home. We appreciate most home owners fi nd the decision making process complex and we are here to help you make the best choices. Every new design begins with a Appliance System Heating Heating & Winter running Calculation type Type Only Hot water cost/month parameters fl oor plan and a heat loss calculation, if there is any information not evident on Heatpump Underfl oor $25,000* $32,800** $290 0.08c/kWh x 16hrs/day your plan our tech team will make contact to ask any relevant questions. Radiators $14,300 $19,700 $160 0.07c/kWh x 6hrs/day DIESEL UNDERFLOOR DOMESTIC Natural Gas Underfl oor $14,900 $20,300 $220 0.07c/kWh x 8hrs/day BOILER HEATING HOT WATER Radiators $14,300 $19,700 $420 0.18c/kWh x 6hrs/day LPG boiler Underfl oor $14,900 $20,300 $560 0.18c/kWh x 8hrs/day powered by Grant Vortex diesel boiler Radiators $19,000 $24,500 $280 0.12c/kWh x 6hrs/day Diesel boiler Underfl oor $19,100 $24,600 $380 0.12c/kWh x 8hrs/day waterware.co.nz Note: Prices include GST and exclude costs associated with network connections and local authority [email protected] waterware.co.nz building consents. *Grant Aerona heatpump only. **Vaillant aroTHERM heatpump only. 0800 WATERWARE V3 WW0025 GRANT Vortex Underfloor Heating Brochure_v3.indd 1-3 22/02/2019 11:55:56 AM System Control | Smart & Simple Your home can be programmed to be warm according to your schedule and budget with an option to include remote system control via a smart phone. Grant Vortex diesel condensing boilers utilize advanced combustion technology to deliver class leading performance, effi ciency and reliability. Typical running cost: 0.12c/kWh Model DBV26 DBV36 DBV46 Floor heating capacity 250m2 350m2 450m2 Maximum effi ciency 95% 97% 93% Height: 860mm 900mm 1234mm Width: 470mm 470mm 563mm Depth: 603mm 603mm 786mm Heatmiser neoStat Thermostat Grant Vortex diesel boilers Mulitple neoStats are used to build a network of wired or wireless thermostats throughout your WHISPER QUIET home. Modern touch button technology and an Comfortplus systems powered by Grant Vortex diesel boilers are a practical option intuitive menu navigation is simple for the home particularly in areas lacking reticulated gas. owner to program and operate. Underfl oor Heating In winter it circulates warm water throughout pipes encapsulated within the concrete slab fl oor and radiantly warms your entire home. Tri-Color Logo With Registration Mark PANTONE PANTONE PANTONE PROCESS 298 CVC 143 CVC 485 CVC BLACK RGB RGB RGB RGB 0 - 174 - 231 252 - 185 - 69 237 - 27 - 45 0 - 0 - 0 CMYK CMYK CMYK CMYK 76% - 9% - 0% - 0% 0% - 30% - 83% - 0% 0% - 100% - 91% - 0% 10% - 10% - 10% - 100% © Disruptive Innovation 2013 Domestic Hot Water All year round it generates enough hot water to meet your entire household demand. Underfl oor Heating Domestic Underfl oor central heating is the most discrete and most comfortable The installation of a diesel boiler is typically more involved and costly than gas boilers but form of central heating. Hot Water off er signifi cant running cost savings over LPG options. The Grant Vortex has the functionality Constant temperature day and night and capacity to generate all of your Grant Vortex diesel boilers are a premium quality, high performance condensing boiler Due to the large thermal mass of a concrete slab, it takes less energy to keep homes domestic hot water requirements. made in Ireland. They are quiet, clean burning and reliable. its temperature stable than allowing it to cool down resulting in a perfectly • Condensing boilers use advanced combustion technology which scavenges energy comfortable home - all of the time. High capacity, high pressure, low cost found in the fl ue gas temperature that would otherwise be lost to the atmosphere No interior compromise Selection of the Protank stainless steel hot resulting in running effi ciencies up to 97%. Warm water is gently circulating through pipes encapsulated within the fl oor water cylinder completes a high capacity, • Whisper quiet operation. slab so the system is eff ectively invisible and silent. Enjoy total freedom when high effi ciency domestic hot water system. utilising wall space and arranging furniture. • Advanced digital control panel enables the boiler to automatically switch duty from Taking advantage of the Grant Vortex heating to domestic hot water production. Warm fl oors low running costs not only reduces • Premium quality powder coated EZI-Fit high level fl ue set. Since heat is radiating from the fl oor, its surface is perfectly warm underfoot. hot water production costs but also Rooms featuring hard surfaces like tiles or polished concrete can become represents a signifi cant saving over the warm and cosy spaces. For carpeted spaces maximum recommended TOG cost of adding another plumbing system value is 2.5. to produce hot water. WW0025 GRANT Vortex Underfloor Heating Brochure_v3.indd 4-6 22/02/2019 11:56:05 AM.
Recommended publications
  • UCS 240 IOM Rev. D
    Model UCS-240 CONDENSING GAS FIRED FLOOR OR WALL MOUNTED BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL Manufactured by: ECR International Inc. 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com P/N 240011654 Rev. D [09/15/2017] VERIFY CONTENTS RECEIVED Safety Relief Valve Fully Assembled Boiler Metal Wall Bracket (Maximum 50 PSI) Temperature Includes essential documents. TP Gauge and Safety Relief Drain Valve Gas Shutoff Valve Document Package Valve Connections Used for measuring outside Used for connecting temperature condensate piping to boiler Condensate Drain Outdoor Sensor Connections 2 P/N 240011654, Rev. D [09/15/2017] TABLE OF CONTENTS 1 - Important Information .................................... 5 9 - Start Up Procedure ........................................ 52 2 - Introduction .................................................... 6 9.1 Fill Condensate Trap with Water ....................52 3 - Component Listing .......................................... 7 9.2 Commission Setup (Water) ...........................52 4 - Locating Boiler ................................................ 8 9.3 Commission Setup (Gas) .............................53 5 - Hydronic Piping ............................................. 11 9.4 Commission Setup (Electric) .........................53 5.2 Special Conditions .......................................11 9.5 Control Panel............................................. 54 5.3 Safety Relief Valve and Air Vent ....................12 9.6 Deaeration Function.....................................55
    [Show full text]
  • Boiler Recognized KD Navien Fulfilling Social and Environment That Brings Creativity by Global Market Responsibility for Better Tomorrow
    Smarter Living Environment Partner, KD Navien O N E R O A D , O N E H E R I T A G E Great Heritage preserving Energy and Environment, creating the right path Introduction of KD Navien C O N T E N T S KD Navien’s response to Energy KD Navien’s pride in technology Korea’s No. 1 Boiler recognized KD Navien fulfilling social and Environment that brings creativity by Global Market responsibility for better tomorrow R E S P O N S E O R I G I N A L I T Y A C H I E V E M E N T D R E A M KD Navien’s R E S P O N S E To Energy and Environment 1951 Musan briquet factory MuSan, the name chosen in the hope that mountains would be covered opening in ruins in Korean rich with woods by reducing the use of firewood. postwar In those days when it was extremely hard to survive cold winter, KyungDong’s journey had started at this small factory making and selling 茂山 good quality briquet. 1978 The beginning of the great In the 1970s that suffered twice from oil crisis, KD Navien which took its dream opening the era of first step with the name of KyungDong machinery during this global zero energy energy crisis, presented a new way to Korean heating industry by launching an all-in-one quadrangle boiler, which was the first residential boiler in domestic market. 1988 The first condensing KD Navien developed the first condensing boiler in Asia with the belief boiler in Asia that condensing is the right way, and with the principle of preserving energy and environment, and been continuing its sole path with condensing technology despite the market ignorance and numerous interference from competitors 1991 Development of artificial KD Navien has successfully developed and supplied the first artificial soil soil creating urban in Korea to purify air pollution in populous cities and is improving urban ecological greenery environment to breath by greenery project utilizing the forsaken area.
    [Show full text]
  • (2015): Performance Rating of Commercial Space Heating Boilers
    ANSI/AHRI Standard 1500 2015 Standard for Performance Rating of Commercial Space Heating Boilers Approved by ANSI on 28 November 2014 IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes AHRI Hydronics Institute Standard BTS-2000 Rev. 06.07. INFORMATIVE NOTE AHRI CERTIFICATION PROGRAM PROVISIONS Scope of the Certification Program (See Section 2 for Scope of the Standard) The certification program includes all gas- and oil-fired steam and hot water Heating Boilers with inputs ranging from 300,000 Btu/h to 2,500,000 Btu/h. Models within a model series, or individual boiler models, having inputs over 2,500,000 Btu/h may be included in the program at the Participant’s option. Certified Ratings The following certification program ratings are verified by test: All steam boilers, and hot water boilers from 300,000 Btu/h up to and including 2,500,000 Btu/h. 1. Thermal Efficiency, % (required) 2. Combustion Efficiency, % (optional) Hot water boilers above 2,500,000 Btu/h.
    [Show full text]
  • Sulfur Heating Oil and Condensing Appliances
    IMPROVED EFFICIENCY AND EMISSIONS WITH LOW- SULFUR HEATING OIL AND CONDENSING APPLIANCES Wai-Lin Litzke, Dr. Thomas Butcher and Roger McDonald ABSTRACT High levels of fine particulate matter (PM2.5) in NYC and surrounding metropolitan areas have been attributed mostly to diesel engines with contributions from oil used for heating during the wintertime. No. 2 heating oil consumption, typically high-sulfur, is concentrated in the Northeast region with about 3.4 billion gallons (1997 data) used annually in the Mid-Atlantic states (NJ, NY and PA). Improved energy efficiency of furnaces and boilers with significant reductions in sulfur oxides and total particulate matter can be achieved through the use of low-sulfur fuels. Reducing sulfur levels even further to ultra-low levels, which is now available as transportation diesel, allows for continued advances in condensing oil-fired systems. These advances allow for up to 10% improvements in energy efficiency or 94% efficient systems. Brookhaven National Laboratory is developing these technologies with the objectives of quantifying the efficiency benefits in addition to characterization of emissions. These new technologies offer significant energy benefits but it is not known what their impacts will be on particulate emissions. For example, in the case of condensing boilers do these systems provide an opportunity to capture some of the particles on wet surfaces before being emitted? This poster will present specific data on the correlation between sulfur levels and PM2.5 using a new, portable dilution tunnel sampling system for condensing boilers and furnaces in residential systems. Schematic of PM2.5 Measurement System Energy Consumption Estimates by Sector (2001), DOE/EIA EPA Conditional Test Method CTM 39 Distillate for Residential Heating Distillate for Transportation Stack 142-mm Filter Heated Box 40000 Mixing Cone R.H.
    [Show full text]
  • Solar Hot Water & Hydronics
    Solar Hot Water & Hydronics Sizing and Selection Guide List Prices 2009 Contractors • Wholesalers STS Solar Storage Plus System Boiler More Solar, Less Gas Solar Recirc Supply Recirculate Excess Hot Water Solar Heat To Gas Fired Tank To Heating Supply Hydronic Heating Air Handler Electric Radiant Element Solar Convector Hot Hot Water 92% Efficient Heating Return Electric Water Capacities Element Hot Water Coil Electric 92% AFUE Element 130,000 BTU Munchkin 199,000 BTU Solar Pump Boiler Potable Module Potable Solar 80 gallon Expansion Expansion Hot Water Tank Tank Recirculation 119 gallon 10K 10K 10K Sensor Sensor Expansion 10K Sensor Solar Pump Tank Sensor Solar Pump Module Taco Module Solar Coil 003 Solar Coil P1 Cold IFC Solar Coil P1 Potable P2 Expansion Tank Solar Heat Exchanger Drain Cold Cold Connects Circulator to Control Circulator & Check Valve Solar Tank Closed Loop Conventional Gas Water Heater www.stssolar.com Solar Thermal Systems • 4723 Tidewater Avenue • Oakland, CA 94601 • t 800-493-8432 • f 510-434-3142 • www.stssolar.com Solar Booklet_0409 Introduction Solar Thermal Systems About STS STS is a California and Nevada primary packager of certified solar hot water systems, solar collectors, tanks and other solar products serving the wholesale, contracting and specification, community. Our products are represented exclusively by Manufacturers Representative JTG/Muir. For technical information, literature and a list of distributors please call 800- 493-8432 and visit our web site at www.stssolar.com. Experience Our company has a combined 55 years of solar thermal experience. We are committed to providing quality systems and components with excel- lent performance designed to operate reliably and durably.
    [Show full text]
  • Library of System Control Strategies
    A BSRIA Guide www.bsria.co.uk Library of System Control Strategies By A J Martin and A P Banyard AG 7/98 Application Guide AG 7/98 LIBRARY OF SYSTEM CONTROL STRATEGIES A J Martin C P Banyard The Building Services Research and Information Association Old Bracknell Lane West, Bracknell, Berkshire RG12 7AH Tel: + 44 (0)1344 426511 Fax: + 44 (0)1344 487575 e-mail: [email protected] www.bsria.co.uk All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means electronic, mechanical, photocopying, recording or otherwise without prior written permission of the publishers. ISBN 0 86022 497 X ©BSRIA 78040 April 1998 EXECUTIVE SUMMARY EXECUTIVE SUMMARY The Library of System Control Strategies provides a reference document for use when specifying, developing and configuring control strategies. The Library is published in five chapters, each containing control strategies relating to the following main types of plant: · Chapter 1: BMS plant start /stop signals · Chapter 2: Heating systems · Chapter 3: Air handling plant · Chapter 4: Pumping · Chapter 5: Cooling systems In each chapter the control of the principal plant items in current use are described. Where there are many plant items which carry out the same function but using different techniques, for example, water heating, the modular format of the Library allows a ‘pick and mix’ selection of plant modules to be made to provide the required configuration of a complete system. Each plant module is shown in the form of a schematic and is described in terms of its general function and how it is controlled.
    [Show full text]
  • Integration of Micro-Cogeneration Units and Electric Storages Into a Micro-Scale Residential Solar District Heating System Operating with a Seasonal Thermal Storage
    energies Article Integration of Micro-Cogeneration Units and Electric Storages into a Micro-Scale Residential Solar District Heating System Operating with a Seasonal Thermal Storage Antonio Rosato * , Antonio Ciervo, Giovanni Ciampi , Michelangelo Scorpio and Sergio Sibilio Department of Architecture and Industrial Design, University of Campania Luigi Vanvitelli, 81031 Aversa, Italy; [email protected] (A.C.); [email protected] (G.C.); [email protected] (M.S.); [email protected] (S.S.) * Correspondence: [email protected]; Tel.: +39-081-501-0845 Received: 31 July 2020; Accepted: 9 October 2020; Published: 19 October 2020 Abstract: A micro-scale district heating network based on the operation of solar thermal collectors coupled to a long-term borehole thermal storage is modeled, simulated and investigated over a period of five years. The plant is devoted to covering the domestic hot water and space heating demands of a district composed of six typical residential buildings located in Naples (southern Italy). Three alternative natural gas-fueled back-up auxiliary systems (condensing boiler and two different technologies of micro-cogeneration) aiming at balancing the solar energy intermittency are investigated. The utilization of electric storages in combination with the cogeneration systems is also considered with the aim of improving the self-consumption of cogenerated electric energy; heat recovery from the distribution circuit is also evaluated to pre-heat the mains water for domestic hot water production. The performances of the proposed plant schemes are contrasted with those of a typical Italian decentralized heating plant (based on the utilization of natural gas-fueled non-condensing boilers).
    [Show full text]
  • Non-Domestic Building Services Compliance Guide
    ONLINE VERSION Compliance Guide Non-Domestic Building Services Non-Domestic Building Services Compliance Guide 2013 edition – for use in England* ONLINE VERSION ONLINE VERSION * Note: Any reference to the Building Regulations in this guide is to the Building Regulations 2010 in England (as amended). These Regulations also apply to the following building work in Wales: (a) work on an excepted energy building as defined in the Schedule to the Welsh Ministers (Transfer of functions) (No 2) Order 2009 (SI 2009/3019); and (b) work that is subject to provisions of the regulations relating to energy efficiency specified in regulation 34 of the Regulations and is carried out to educational buildings, buildings of statutory undertakers and Crown buildings, or carried out by Crown authorities. This guidance comes into effect on 6 April 2014. Work started before this date remains subject to the earlier edition of the guidance. Work subject to a building notice, full plans application or initial notice submitted before this date will also remain subject to the earlier edition of the guidance, provided it is started before 6 April 2015. For other jurisdictions in the UK, it will be necessary to consult their own building regulations and guidance. ONLINE VERSION ONLINE VERSION Contents * Note: Any reference to the Building Regulations in this guide is to the Building Regulations 2010 in England (as amended). These Regulations also apply to the following building work in Wales: Contents (a) work on an excepted energy building as defined in the Schedule to the Welsh Ministers (Transfer of functions) (No 2) Order 2009 (SI 2009/3019); and (b) work that is subject to provisions of the regulations relating to energy efficiency specified in regulation 34 of the Regulations and is carried out to educational buildings, buildings of Section 1: Introduction 5 statutory undertakers and Crown buildings, or carried out by Crown authorities.
    [Show full text]
  • Condensing Boiler Assessment: Peachtree Summit Federal Building
    Prepared for the General Services Administration By the Pacific Northwest National Laboratory November 2012 Condensing Boiler Assessment: Peachtree Summit Federal Building Atlanta, Georgia S.A. Parker J. Blanchard The Green Proving Ground program leverages GSA’s real estate portfolio to evaluate innovative sustainable building technologies and practices. Findings are used to support the development of GSA performance specifications and inform decision-making within GSA, other federal agencies, and the real estate industry. The program aims to drive innovation in environmental performance in federal buildings and help lead market transformation through deployment of new technologies. DISCLAIMER This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor the Pacific Northwest National Laboratory (PNNL), nor Battelle Memorial Institute, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by its trade name, trademark, manufacturer, or otherwise, does not constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or the Pacific Northwest National Laboratory, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof or the Pacific Northwest National Laboratory, or Battelle Memorial Institute.
    [Show full text]
  • Condensing Boiler Basics
    Maximizing the Efficiency of Condensing Boilers Presented by Matt Napolitan, P.E., CPMP, LEED AP BD+C & Brent Weigel, Ph.D., P.E., LEED AP BD+C 1 Introduction • Condensing boilers are commonly specified and installed in buildings today for efficiency benefit. 2 Introduction • Condensing boilers are commonly specified and installed in buildings today for efficiency benefit. – System selection and setpoints are key to achieving rated efficiency!!! 3 Introduction • The concepts and recommendations in this presentation are applicable to . 4 Introduction • The concepts and recommendations in this presentation are applicable to . – Both new construction and existing buildings. – Both commercial and residential buildings. 5 Introduction • The concepts and recommendations in this presentation are applicable to . – Both new construction and existing buildings. – Both commercial and residential buildings. • $0 capital cost opportunities!!! 6 Introduction • Learning Objective #1: – Be able to explain the impact of hot water temperature on condensing boiler efficiency. – Understanding efficiency ratings. • Learning Objective #2: – Be able to explain the relationship between outdoor air temperature, heating load, and heating hot water temperature. 7 Introduction • Learning Objective #3: – Be able to estimate hot water temperature reset setpoints that maximize condensing hours and satisfy heating loads. • Learning Objective #4: – Be able to size terminal heating equipment for maximum condensing hours. 8 Introduction • Learning Objective #5: – Describe
    [Show full text]
  • New Developments 2021 2 / 3 TOP NEW DEVELOPMENTS for 2021
    New developments 2021 2 / 3 TOP NEW DEVELOPMENTS FOR 2021 Products & systems New electronic platform networks Viessmann appliances to a single system The new electronic platform networks the various Viessmann product families to each other, to energy systems and directly to all digital services. This allows all the appliances to "talk" to each other, requiring only one app for all applications. Vitoguide for our trade partners and ViCare for end customers. Pages 10 / 11 Heating with hydrogen – innovative technology for a climate-neutral future The first gas condensing boilers and fuel cells certified to run with blends of up to 20 percent hydrogen will be coming onto the market in 2021. This makes Viessmann a leading innovator in the use of hydrogen to generate heat and power. Pages 12 / 13 New generation of heat pumps with high flow temperature With a flow temperature of up to 70 °C, Vitocal 25x-A was developed with modernisation projects in mind. You can continue using any existing radiators. With its extremely low GWP (Global Warming Potential) value of 3, the "green" refrigerant R290 (propane) these units use is especially environmentally responsible. Pages 24 / 25 Air purification and ventilation system for rooms with up to 30 people Ventilation systems have become an even hotter topic since the start of the Corona pandemic. Not only does the Vitovent 200-P ventilation unit reduce the viral load in aerosols, it also lowers the CO2 load in closed rooms. The result is optimum indoor air quality at all times, regardless of how unusual the situation is. Pages 36 / 37 Especially slimline and compact ventilation system with heat exchanger With its low installed height of 245 mm and a maximum air flow rate of 300 m3/h, the new Vitoair FS mechanical ventilation system is particularly slimline and extremely compact.
    [Show full text]
  • Condensing Tech- Nology for Added Value When Heating with Oil
    ROTEX oil condensing boiler Condensing tech- nology for added value when heating with oil The ROTEX A1 oil condensing boiler delivers maximum efficiency with every type of heating oil. It is environmentally compatible, economical and prepa- red for bio-oil. A+ ++ XL A * ROTEX system consisting of: A1 BO 20-e, SCS 538/16/0-DB, RoCon control, 4 solar collectors V26P ROTEX oil condensing boiler Lower your consumption – the modern way ROTEX oil condensing technology adds value Saving is environmental friendly Selecting the right boiler for your oil heating system is a deci- The ROTEX A1 defines the current state of the art in oil boiler sion affecting the next 15 to 25 years. The fuel costs for your technology. Minimal emissions, straightforward operation and heating system over this time will be multiples of the initial maximum energy utilisation characterise the ROTEX A1 oil con- investment. Fuel costs, therefore, offer you the greatest poten- densing boiler. The most advanced technology converts the tial for savings. Only condensing technology achieves virtually fuel used into useful heat, with virtually no losses. This protects complete energy utilisation. When replacing existing boilers, the environment and your wallet. Reduced energy consump- the ROTEX A1 achieves energy savings up to 40 % thanks to its tion means not only lower heating bills, but also protection of outstand ing levels of efficiency. So that you can be sure that energy resources and lower CO2 emissions. your investment will pay off, ROTEX also guarantees the boiler body for 15 years. Be prepared for anything – ready for bio-oil In future, an increasing proportion of bio-oil, or bio-oil constitu- ents, will be added to conventional heating oil.
    [Show full text]