Thermo-Hygro-Barometer with External Probe Thermo-hygro-barometer with external probe code: D4141 Thermometer, hygrometer, barometer is designed for measurement and datalogging of temperature, relative humidity and atmospheric pressure into the internal non-volatile memory. Also barometric pressure tendency reading available. Free PC program enables to transfer recorded data to the computer for evaluation. Audio and optical alarm of measured values. Memory of minimum and maximum measured values. Function Hold - manual storing of actual values for later displaying. Data logger is connected to the PC through included USB cable only for data trasfer from the memory. During connection with the PC no measurement and record is enabled. Thermometer - hygrometer - barometer with external air temperature- humidity probe on a 1 meter cable. Probe diameter is 18mm, length 135mm. Built-in indoor temperature and air pressure sensors. Technical data TEMPERATURE SENSOR Measuring range -10 to +60 °C (internal); -30 to +105 °C (external) Accuracy ±0.4 °C Resolution 0.1 °C HUMIDITY SENSOR Measuring range 0 to 100 % RH Accuracy ±2.5 % RH from 5 to 95 % at 23 °C Resolution 0.1% RH DEW POINT Measuring range -60 to +80 °C Accuracy ±1.5 °C at ambient temperature T <25 °C and RH >30 % Resolution 0.1 °C ATMOSPHERIC PRESSURE SENSOR Measuring range 800 to 1100 hPa Accuracy ±2hPa at 23°C Resolution 0.1 hPa GENERAL TECHNICAL DATA Operating temperature electronics -10 to +60 °C, external probe -30 to +105 °C Channels internal sensor of temperature and atmospheric pressure, 1x connectable temperature+humidity probe Acoustic signalization + backlit LCD YES Memory 16,000 values (non-cyclic record) Recording interval adjustable from 10 s to 24 h 1/2 Measuring interval and display reading refresh 0.7 to 5 s Recording mode noncyclic - data logging stops after filling the memory<br>cyclic - after filling memory oldest data is overwritten by new Real time clock year, leap year, month, day, hour, minute, second Power battery 9 V or 12 Vss adaptor with NiMH 9 V battery Battery life approx. 6 months Protection class IP20 Dimensions (without connectors) 191 x 71 x 27 mm; length/diameter of external probe 135/18 mm External probe cable length 1 meter Weight (including batteries) approx. 155 g Warranty 3 years 2/2 Powered by TCPDF (www.tcpdf.org).
Recommended publications
  • Downloaded 09/25/21 08:19 AM UTC 662 JOURNAL of ATMOSPHERIC and OCEANIC TECHNOLOGY VOLUME 15 Mer 1987; Muller and Beekman 1987; Crescenti Et Al
    JUNE 1998 BREAKER ET AL. 661 Preliminary Results from Long-Term Measurements of Atmospheric Moisture in the Marine Boundary Layer in the Gulf of Mexico* LAURENCE C. BREAKER National Weather Service, NCEP, NOAA, Washington, D.C. DAVID B. GILHOUSEN National Weather Service, National Data Buoy Center, NOAA, Stennis Space Center, Mississippi LAWRENCE D. BURROUGHS National Weather Service, NCEP, NOAA, Washington, D.C. (Manuscript received 1 April 1997, in ®nal form 18 July 1997) ABSTRACT Measurements of boundary layer moisture have been acquired from Rotronic MP-100 sensors deployed on two National Data Buoy Center (NDBC) buoys in the northern Gulf of Mexico from June through November 1993. For one sensor that was retrieved approximately 8 months after deployment and a second sensor that was retrieved about 14 months after deployment, the pre- and postcalibrations agreed closely and fell within WMO speci®cations for accuracy. A second Rotronic sensor on one of the buoys provided the basis for a detailed comparison of the instruments and showed close agreement. A separate comparison of the Rotronic instrument with an HO-83 hygrometer at NDBC showed generally close agreement over a 1-month period, which included a number of fog events. The buoy observations of relative humidity and supporting data from the buoys were used to calculate speci®c humidity. Speci®c humidities from the buoys were compared with speci®c humidities computed from observations obtained from nearby ship reports, and the correlations were generally high (0.7± 0.9). Uncertainties in the calculated values of speci®c humidity were also estimated and ranged between 0.27% and 2.1% of the mean value, depending on the method used to estimate this quantity.
    [Show full text]
  • Manual of Aeronautical Meteorological Practice --`,,```,,,,````-`-`,,`,,`,`,,`
    Doc 8896 AN/893 Manual of Aeronautical Meteorological Practice --`,,```,,,,````-`-`,,`,,`,`,,`--- Approved by the Secretary General and published under his authority Ninth Edition — 2011 International Civil Aviation Organization Copyright International Civil Aviation Organization Provided by IHS under license with ICAO No reproduction or networking permitted without license from IHS Not for Resale Suzanne --`,,```,,,,````-`-`,,`,,`,`,,`--- Copyright International Civil Aviation Organization Provided by IHS under license with ICAO No reproduction or networking permitted without license from IHS Not for Resale Doc 8896 AN/893 Manual of Aeronautical Meteorological Practice --`,,```,,,,````-`-`,,`,,`,`,,`--- Approved by the Secretary General and published under his authority Ninth Edition — 2011 International Civil Aviation Organization Copyright International Civil Aviation Organization Provided by IHS under license with ICAO No reproduction or networking permitted without license from IHS Not for Resale Published in separate English, French, Russian and Spanish editions by the INTERNATIONAL CIVIL AVIATION ORGANIZATION 999 University Street, Montréal, Quebec, Canada H3C 5H7 For ordering information and for a complete listing of sales agents and booksellers, please go to the ICAO website at www.icao.int Seventh edition 2006 Eighth edition 2008 Ninth edition 2011 ICAO Doc 8896, Manual of Aeronautical Meteorological Practice Order Number: 8896 ISBN 978-92-9231-828-4 © ICAO 2011 All rights reserved. No part of this publication may be reproduced,
    [Show full text]
  • ESSENTIALS of METEOROLOGY (7Th Ed.) GLOSSARY
    ESSENTIALS OF METEOROLOGY (7th ed.) GLOSSARY Chapter 1 Aerosols Tiny suspended solid particles (dust, smoke, etc.) or liquid droplets that enter the atmosphere from either natural or human (anthropogenic) sources, such as the burning of fossil fuels. Sulfur-containing fossil fuels, such as coal, produce sulfate aerosols. Air density The ratio of the mass of a substance to the volume occupied by it. Air density is usually expressed as g/cm3 or kg/m3. Also See Density. Air pressure The pressure exerted by the mass of air above a given point, usually expressed in millibars (mb), inches of (atmospheric mercury (Hg) or in hectopascals (hPa). pressure) Atmosphere The envelope of gases that surround a planet and are held to it by the planet's gravitational attraction. The earth's atmosphere is mainly nitrogen and oxygen. Carbon dioxide (CO2) A colorless, odorless gas whose concentration is about 0.039 percent (390 ppm) in a volume of air near sea level. It is a selective absorber of infrared radiation and, consequently, it is important in the earth's atmospheric greenhouse effect. Solid CO2 is called dry ice. Climate The accumulation of daily and seasonal weather events over a long period of time. Front The transition zone between two distinct air masses. Hurricane A tropical cyclone having winds in excess of 64 knots (74 mi/hr). Ionosphere An electrified region of the upper atmosphere where fairly large concentrations of ions and free electrons exist. Lapse rate The rate at which an atmospheric variable (usually temperature) decreases with height. (See Environmental lapse rate.) Mesosphere The atmospheric layer between the stratosphere and the thermosphere.
    [Show full text]
  • Report Rapport
    A Report Rapport Atomic Energy Commission de contr6le Contr.ol.Bo&rd de f'6nergie atomique ca9111007 THE PICKERING MESONET 1988 DATA REPORT by J.R. Salmon and P.A. Taylor Atomic Energy Commission de controle INFO-0348 Control Board de I'energie atomique PO Box 1046 CP 1046 Oliawa Canada Ollawa. Canada KIP5S9 K1P5S9 THE PICKERING MESONET 1988 DATA REPORT by J.R. Salmon and P.A. Taylor A research report prepared for the Atomic Energy Control Board Ottawa, Canada Project No. 2.129.1 October 1989 Canada Research report THE PICKERING MESONET —1988 DATA REPORT By J.R. Salmon and P.A. Taylor ABSTRACT This report describes the demonstration mesoscale meteorological monitoring network ("mesonet") installed in the vicinity of the Pickering Nuiclear Generating Station. It also summarizes the data collected by the network during 1988 and provides some examples of situations in which mesosclae effects dominate the local wind flow. RESUME Le present rapport de"crit le r6seau de controle me'te'orologique d'e'chelle moyenne de demonstration («mesonet») installs pres de la centrale nucllaire Pickering. II resume aussi les donne'es recueillies par le rdseau en 1988 et fournit quelques exemples de situations ou les effets d'e'chelle moyenne dominent la coulle de vent local. DISCLAIMER The Atomic Energy Control Board is not responsible for the accuracy of the statements made or opinions expressed in this publication, and neither the Board nor the authors assume liability with respect to any damage or loss incurred as a result of the use made of the information contained in this publication.
    [Show full text]
  • Meteorological Monitoring Guidance for Regulatory Modeling Applications
    United States Office of Air Quality EPA-454/R-99-005 Environmental Protection Planning and Standards Agency Research Triangle Park, NC 27711 February 2000 Air EPA Meteorological Monitoring Guidance for Regulatory Modeling Applications Air Q of ua ice li ff ty O Clean Air Pla s nn ard in nd g and Sta EPA-454/R-99-005 Meteorological Monitoring Guidance for Regulatory Modeling Applications U.S. ENVIRONMENTAL PROTECTION AGENCY Office of Air and Radiation Office of Air Quality Planning and Standards Research Triangle Park, NC 27711 February 2000 DISCLAIMER This report has been reviewed by the U.S. Environmental Protection Agency (EPA) and has been approved for publication as an EPA document. Any mention of trade names or commercial products does not constitute endorsement or recommendation for use. ii PREFACE This document updates the June 1987 EPA document, "On-Site Meteorological Program Guidance for Regulatory Modeling Applications", EPA-450/4-87-013. The most significant change is the replacement of Section 9 with more comprehensive guidance on remote sensing and conventional radiosonde technologies for use in upper-air meteorological monitoring; previously this section provided guidance on the use of sodar technology. The other significant change is the addition to Section 8 (Quality Assurance) of material covering data validation for upper-air meteorological measurements. These changes incorporate guidance developed during the workshop on upper-air meteorological monitoring in July 1998. Editorial changes include the deletion of the “on-site” qualifier from the title and its selective replacement in the text with “site specific”; this provides consistency with recent changes in Appendix W to 40 CFR Part 51.
    [Show full text]
  • The Calibration of Hygrometer (Lecture and Training )
    The calibration of Hygrometer (Lecture and Training ) HAGIYA Satoshi Japan Meteorological Agency Meteorological Instrument Center 8 Nov. 2016 Outline 1. Measurement methods of Humidity(theory) 2. Traceability in JMA 3. Calibration methods of Hygrometer 4. Practice (Calibration and check of electric hygrometer) Meteorological Instrument Center Japan Meteorological Agency 1.Measurement methods of humidity(theory) 1.1 Sorption method Changes of the dimensions Changes of electrical properties 1.2 Psychrometric method Difference between the dry-bulb and wet-bulb temperatures related to the ambient humidity 1.3 Condensation methods Equilibrium vapor pressure at the surface of a salt solution Sense condensation with an optical detector Meteorological Instrument Center Japan Meteorological Agency 1.1 Sorption method ●Changes of the dimensions hair hygrograph Hair bundle Meteorological Instrument Center Japan Meteorological Agency 1.1 Sorption method ●Changes of electrical properties electronic hygrometer(capacitive type) converter sensor probe sensor filter Meteorological Instrument Center Japan Meteorological Agency 1.2 Psychrometric method ●Difference between the dry-bulb and wet-bulb temperatures related to the ambient humidity aspirated psychrometer JMA type Assuman type wet-bulb dry-bulb Meteorological Instrument Center Japan Meteorological Agency 1.2 Psychrometric method ●Difference between the dry-bulb and wet-bulb temperatures related to the ambient humidity Manned Observatory , Special AWS Check (every 3 months) Ventilated shield Electric thermometer Electric hygrometer Meteorological Instrument Center Japan Meteorological Agency 1.3 Condensation methods ●Equilibrium vapor pressure at the surface of a salt solution (Heated salt-solution method) lithium chloride heated condensation dew point hygrometer (dew cell) resistance thermometer wire as electrodes humidity-sensitive part ・An operational equilibrium temperature exists for the instrument, depending upon the ambient water vapor pressure.
    [Show full text]
  • Aer Rodrom Me Meteo S Orologi Study Gr Ical Obs
    AMOFSG/9-IP/8 20/9/11 AERODROME METEOROLOGICAL OBSERVATION AND FORECAST STUDY GROUP (AMOFSG) NINTH MEETING Montréal, 26 to 30 September 2011 Agenda Item 5: Observing and forecasting at the aerodrome and in the terminal area 5.1: Observations AUTO METAR SYSTEM AT CIVIL AIRPORTS IN THE NETHERLANDS: DESCRIPTION AND EXPERIENCES (Presented by Jan Sondij) SUMMARY This paper provides an overview of the AUTO METAR system used in the Netherlands. The system includes the entire technical infrastructure used for the automated generation of all meteorological aeronautical observation reports including baack-up systems and procedures. It also includes the supervision of all issued reports by a remote meteorologist who can provide additional information to ATC. Experiences of the performance and acceptance by ATC of the AUTO METAR system are reported. The process of how this was achieved is presented as well as lessons learned. 1. INTRODUCTION 1.1 The eighth meeting of the Aerodrome Meteorological Observation and Forecast Study Group (AMOFSG/8) led to the formation of an ad-hoc group tasked with reviewing the options for the future reporting of present weather in fully automated weather reports. More background on automated weather observations is provided in this information paper. 1.2 This information paper describes the so-called AUTO METAR system at civil airports in the Netherlands. The process of introduction and approval as well as experiences are presented. Some highlights are reported below. Details are given in the appended document entitled AUTO METAR System at Civil Airports in the Netherlands: Description and Experiences by Wauben and Sondij. (49 pages) AMOFSG.9.IP.008.5.en.docx AMOFSG/9-IP/8 - 2 - 1.3 Since 15 March 2011, the AUTO METAR system has been operational 24/7 at Rotterdam-The Hague Airport (EHRD).
    [Show full text]
  • Differences Between Automatic and Manual Meteorological Observation
    Differences between Automatic and Manual Meteorological Observation Wang Ying Liu Xiaoning Ju Xiaohui National Meteorological Information Center, Beijing, China Tel.:+86 10 68407255, E-mail:[email protected] Abstract Based on the data from both automatic and manual meteorological observation in 700 stations of China from 2001 to 2005, analyses have been made on the differences of automatic and manual observation in temperature, pressure, relative humidity, ground surface temperature, wind direction and velocity, and precipitation, together with the difference, percentage error and matching rate of wind directions between the two kinds of observation. The differences of all the elements have been studied to get the distribution feature in China and the possible influence of automatic temperature observation on the continuity of temperature data has been tested. The results show that there exists certain difference between automatic and manual meteorological observation, but in most areas the differences of all elements are accepted due to the error range of automatic stations. Many factors may cause the differences, including the flaw of instruments and different observational methods. The differences of all elements are distributed variously in the whole country. Even the difference of the same element may vary on different climatic conditions. The time series of auto and manual observation still need to be further tested to identify significant difference and make homogeneous correction if there is any, to make the data of auto and manual observation valid in use. Automatic observation station has some influence on the annual temperature time series. The general difference is not significant, but homogeneity test should be involved if the data of auto and manual observation in temperature are both referred to in practice.
    [Show full text]
  • To Marine Meteorological Services
    WORLD METEOROLOGICAL ORGANIZATION Guide to Marine Meteorological Services Third edition PLEASE NOTE THAT THIS PUBLICATION IS GOING TO BE UPDATED BY END OF 2010. WMO-No. 471 Secretariat of the World Meteorological Organization - Geneva - Switzerland 2001 © 2001, World Meteorological Organization ISBN 92-63-13471-5 NOTE The designations employed and the presentation of material in this publication do not imply the expression of any opinion whatsoever on the part of the Secretariat of the World Meteorological Organization concerning the legal status of any country, territory, city or area, or of its authorities, or concerning the delimitation of its frontiers or boundaries. TABLE FOR NOTING SUPPLEMENTS RECEIVED Supplement Dated Inserted in the publication No. by date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 CONTENTS Page FOREWORD................................................................................................................................................. ix INTRODUCTION......................................................................................................................................... xi CHAPTER 1 — MARINE METEOROLOGICAL SERVICES ........................................................... 1-1 1.1 Introduction .................................................................................................................................... 1-1 1.2 Requirements for marine meteorological information....................................................................... 1-1 1.2.1
    [Show full text]
  • An Analysis of Changing Measurement Techniques on The
    An Analysis of Changing Instrumentation on the Dew Point Record in Iowa ANDREW STERN MENTOR: DR. BRIAN HORNBUCKLE Overview Background History of observations Types of instruments Procedure Results Background Senior meteorology thesis: dew points are rising across the state Wanted to make sure instrument changes had no effect Airport Instrumentation History HO 60 hygrothermometer 1985 - HO 83 hygrothermometer 1995 - ASOS 2006 - ASOS upgrade: DTS1 dew point sensor Chilled Mirror Hygrometer • Mirror is cooled until dew temperature is reached • A light is pointed at the mirror, when dew forms the light is dispersed in • This indicates the dew temperature DTS1 Dew point sensor Measures relative humidity and outputs dew point temperature through a calculation Installed to reduce the maintenance costs of the chilled mirror hygrometer Data Obtained from Iowa Environmental Mesonet Record is from 1973 to 2012 A few days were missing; filled in with high/low from NWS Coop Dew points were estimated from surrounding days Procedure Special thanks to Lendie Follett Statistical models fit to each separate instrument period These models detrended the data and obtained the variability Results – High Temperature Daily High Temperature Instrument Standard Dev. 95 Ho 60 7.0 Ho 83 7.3 75 ASOS 7.2 55 DTS1 7.1 Slope = 0.0001 35 R² = 0.0003 15 -5 Results - Low Temperature Daily Low Temperature Instrument Standard 80 Dev. Ho 60 7.3 60 Ho 83 7.3 ASOS 7.1 40 DTS1 6.9 Slope = 0.0002 20 R² = 0.0011 0 -20 Results – High Dew Point Daily High Dew Point Instrument Standard 80 Dev.
    [Show full text]
  • Terrarium Thermometer-Hygrometer with 2 Remote Sensor Probes
    digital TERRarium thermometer-hygrometer with 2 remote sensor probes SETTING THE CLOCK AND DATE 12 MONTH LIMITED WARRANTY 1. Press (MODE) button and hold down for three seconds. FRONT WHAT THE WARRANTY COVERS: The minutes on clock will begin flashing. Central Garden & Pet Co. (Company) warrants 2. Press (ADJ) button to change value of the minutes, hour, this product (see Exclusions below) to the 12/24 hour, month and day. LCD DISPLAY AM PM 12:00 original purchaser against defective material MAX MIN °F and workmanship that occurs during normal 3. Press (MODE) button to switch between minutes, hour, TEMPERATURE 75.9 12/24 hour, month and day. COMFORT use for 12 months from the date of original SENSOR PROBE WET MAX DRY MIN 30 % NOTE: Original screen will return after one minute purchase. Company will, at Company’s option, of inactivity. either repair or replace same without charge SENSOR (no cash refunds will be made). To view date press (ADJ) button SUCTION CUP EXCLUSIONS: SETTING THE ALARM CLOCK 1. Damage resulting from accident, misuse, abuse, 1. Press (MODE) button to switch from clock to alarm clock. lack of reasonable care, subjecting the product 2. While alarm is displayed press (MODE) button and hold to any but the specified electrical service, other down for three seconds. The minutes on alarm clock will than normal and ordinary use of the product, begin flashing. 59" LONG CORD subjecting the product to abnormal working 3. Press (ADJ) button to change value of the minutes and hour. conditions or any other failure not resulting SENSOR SENSOR from defects in materials or workmanship.
    [Show full text]
  • Prototyping Low-Cost Automatic Weather Stations for Natural Disaster Monitoring
    Prototyping Low-Cost Automatic Weather Stations for Natural Disaster Monitoring Gabriel F. L. R. Bernardesa, Rogerio´ Ishibashib, Andre´ A. S. Ivob, Valerio´ Rosseta, Bruno Y. L. Kimuraa,∗ aInstitute of Science and Technology, Federal University of S˜aoPaulo (ICT/UNIFESP), S˜aoJos´edos Campos - SP, Brazil bBrazilian National Center for Monitoring and Early Warnings of Natural Disasters (Cemaden), S˜aoJos´edos Campos - SP, Brazil Abstract Weather events put human lives at risk mostly when people might reside in areas susceptible to natural disasters. Weather monitoring is a pivotal remote sensing task that is accomplished in vulnerable areas with the support of reliable weather stations. Such stations are front-end equipment typically mounted on a fixed mast structure with a set of digital and magnetic weather sensors connected to a datalogger. While remote sensing from a number of stations is paramount, the cost of professional weather instruments is extremely high. This imposes a challenge for large-scale deployment and maintenance of weather stations for broad natural disaster monitoring. To address this problem, in this paper, we validate the hypothesis that a Low-Cost Automatic Weather Station system (LCAWS) entirely developed from commercial-off-the-shelf and open-source IoT technologies is able to provide data as reliable as a Professional Weather Station (PWS) of reference for natural disaster monitoring. To achieve data reliability, we propose an intelligent sensor calibration method to correct weather parameters. From the experimental results of a 30-day uninterrupted observation period, we show that the results of the calibrated LCAWS sensors have no statistically significant differences with the PWS’s results.
    [Show full text]