Study of Building Material Emissions and Indoor Air Quality ROTCK

Total Page:16

File Type:pdf, Size:1020Kb

Study of Building Material Emissions and Indoor Air Quality ROTCK Study of Building Material Emissions and Indoor Air Quality by Xudong Yang M.E., Thermal Energy Engineering Tsinghua University, 1993 Submitted to the Department of Architecture on August 6, 1999 in partial fulfillment of the requirements for the Degree of Doctor of Philosophy in the field of Architecture: Building Technology at the Massachusetts Institute of Technology September 1999 @ 1999 Massachusetts Institute of Technology. All rights reserved. Signature of Author Department of Architecture August 6, 1999 Certified by _ Qingyan Chen Associate Professor of Building Technology Thesis supervisor Accepted by Stanford Anderson Chairman, Departmental Committee on Graduate Students Head, Department of Architecture ROTCK Thesis Committee: Leon R. Glicksman, Professor of Building Technology and Mechanical Engineering Ain A. Sonin, Professor of Mechanical Engineering Leslie K. Norford, Associate Professor of Building Technology Study of Building Material Emissions and Indoor Air Quality by Xudong Yang Submitted to the Department of Architecture on August 6, 1999 in partial fulfillment of the requirements for the Degree of Doctor of Philosophy in the field of Architecture: Building Technology ABSTRACT Building materials and furnishings emit a wide variety of indoor pollutants, such as volatile organic compounds (VOCs). At present, no accurate models are available to characterize material emissions and sorption under realistic indoor conditions. The objective of this thesis is to fill that gap. Using the emission data measured in small-scale and full-scale environmental chambers, this investigation has developed a numerical model for simulating emissions of "wet" materials applied to porous substrates. This model considers VOC mass transfer processes in the air, material-air interface, material film, and the substrate. The model can predict "wet" material emissions under different environmental conditions (i.e., temperature, velocity, turbulence, and VOC concentration in the air) with reasonable accuracy. We developed two models for simulating VOC emissions from dry materials. One is a numerical model for short-term predictions, the other is an analytical model for long-term predictions. The models have been successfully used to examine the VOC emissions from two particleboard samples and a polypropene Styrene-Butadiene Rubber (SBR) carpet. A VOC sorption model has also been developed to analytically solve the VOC sorption rate as a function of air-phase concentrations. The model has been validated using an analytical solution as well as data obtained from sorption experiments. The emission and sorption models that we developed have been further used to study indoor air quality (IAQ) in a small office with different ventilation systems. The results show that displacement ventilation may not provide better IAQ than mixing systems if the VOC sources are from the floor. Further, our study shows sink effects from internal walls of gypsum board. Thesis Supervisor: Qingyan Chen Title: Associate Professor of Building Technology ACKNOWLEDGEMENTS I would like to thank my supervisor, Professor Qingyan (Yan) Chen. For the past three years, he has been a constant source of guidance and support. His insightful comments and helpful discussions are invaluable to this work. I am especially grateful for his understanding, support, and encouragement when I face difficulties and failure. With his high standards in research, teaching, and personal integrity, Yan has been a role model for me. My thanks also extend to the members of my thesis committee, Professors Leon Glicksman, Ain Sonin, and Leslie Norford. They give me valuable comments and insightful feedback in every phase of my research. I am also grateful to the National Research Council (NRC) of Canada for allowing me to use their test facilities. Special thanks are given to Dr. Jianshun Zhang, Dr. John Shaw, Dr. Jie Zeng, Mr. Gang Nong, Dr. Jiping Zhu, Mr. Bob Magee, Ms. Ewa Lusztyk, Dr. Yan An, and Dr. Awad Bodalal for their cooperation, assistance, and helpful discussions. My sincere thanks are also given to Professor Yi Jiang of Tsinghua University, Professor Shuzo Murakami of University of Tokyo, Professor John Spengler of Harvard School of Public Health, Drs. John Chang and Zhishi Guo of U.S. Environmental Protection Agency, Dr. Xiaoxiong (John) Yuan of Applied Materials, Inc., and Dr. Philomena Bluyssen of TNO (the Netherlands) for their advise, encouragement, and helpful discussions. I would also like to express my appreciation to all staff members and colleagues of the Building Technology Program for their help and support. Especially, I want to thank Dorrit Schuchter, Kathleen Ross, Chunxin Yang, Jelena Srebric, Weiran Xu, Wei Zhang, Shiping (George) Hu, Junjie Liu, and Yi Jiang. Finally, I am deeply indebted to my parents, my wife, and my brothers for their love, support, and encouragement all the time. DEDICATION To my parents, Yong Yang and Shuxian Zhang and To my wife, Qing Shi CONTENTS Abstract 3 Acknowledgements 4 Dedication 5 Contents 6 1. Introduction 8 1.1 Overview of Problems Associated with Indoor Air Quality 8 1.2 Methods for Measuring Building Material Emissions 10 1.3 Methods for Modeling Building Material Emissions 13 1.4 Aim of the Present Work 16 2. Measurements of VOC Emissions from "Wet" Coating Materials 18 2.1 Introduction 18 2.2 Experimental Method 19 2.3 Results and Discussion 29 2.4 Conclusions 43 3. Modeling of VOC Emissions from "Wet" Coating Materials Applied to Porous Substrates 44 3.1 Introduction 44 3.2 The Emission Mechanisms 45 3.3 The Mathematical Model 47 3.4 Numerical Method 59 3.5 Determination of Material Properties for Numerical Simulation 68 3.6 Results and Discussion 71 3.7 Conclusions 107 4. Modeling of VOC Emissions from Dry Materials 108 4.1 Introduction 108 4.2 The Numerical Method for Short-term Predictions 109 4.3 Development of a Long-term Model for Dry Materials 135 4.4 Conclusions 142 5. Modeling of VOC Sorption on Building Materials 143 5.1 Introduction 143 5.2 Development of a New Sorption Model 147 5.3 Validation of the New Sorption Model Using an Analytical Solution 153 5.4 Experimental Validation of the Sorption Model 158 5.5 Conclusions 164 6. Study of Indoor Air Quality (IAQ) in a Room with Different Ventilation Systems 165 6.1 Introduction 165 6.2 Model for IAQ Studies 167 6.3 Case Study 170 6.4 Conclusions 194 7. Conclusions and Recommendations 196 7.1 Experimental Approach 196 7.2 Modeling Approach 197 7.3 Model Applications 199 7.4 Limitations of the Current Work 200 7.5 Future Perspectives 200 References 201 Appendix 211 Nomenclature 214 Chapter 1 Introduction Indoor air quality (IAQ) is currently of great public concern. This chapter reviews the problems associated with IAQ and current methodology in measuring and modeling the volatile organic compound (VOC) emissions from various building materials and furnishings. The review indicates a need for developing advanced models to fully characterize building material emissions and their impact on IAQ, which comprises the major objective of this thesis. 1.1 Overview of Problems Associated with Indoor Air Quality Every day we breathe 10 m3 of air. This amount is equivalent to 10 housefuls a year, yet this number can increase a factor of 10 via physical activities. This partly explains why people have been extremely concerned about air quality since ancient times. For a long time, however, the concern was almost exclusively with air quality in ambient air. Although some hygienists studied indoor air in 1800's (e.g., Pettenkofer, 1872), concern about the effects of indoor air on human health arose in the past 20 years. Today, indoor air pollution has been identified by the U.S. Environmental Protection Agency (EPA) and World Health Organization (WHO) as one of the top environmental risks to the nations' health (WHO, 1989; US EPA, 1990). The high risk from exposure to indoor pollution reflects the elevated concentration of indoor contaminants, the large number of people exposed to indoor air pollution, and the amount of time spent indoors. The causes of elevated indoor contaminant concentrations are mainly due to two reasons. First, with the advancement of modern technology, the types and amounts of contaminants released into the indoor environment have increased dramatically. New buildings contain many synthetic building materials and furnishings from walls to carpets to air conditioning systems. Use of these new materials and furnishings have resulted in a large number of new indoor pollutants in greater concentrations (van der Wal et al., 1991; Brown et al., 1994). On the other hand, in order to save energy, the air tightness of buildings has been improved and the supply of fresh air (by either natural or mechanical ventilation) has been reduced (Maga and Gammage, 1985; Esmen, 1985). The effects of these two factors combined have increased the indoor air pollutant levels significantly. Studies indicate that indoor air is far more polluted than outdoor air. As evidence, a series of long-term EPA studies of human exposure to air pollutants indicated that indoor levels of many pollutants may be 25 times, and occasionally more than 100 times, higher than outdoor levels (US EPA, 1988). As a result of deteriorated IAQ, numerous cases of health complaints among employees in office buildings have been lodged with federal and state agencies. An EPA report (1991) suggested that up to 30 percent of new and remodeled buildings worldwide have been the subject of a significant number of complaints related to IAQ. The complaints can be divided into two categories: sick building syndrome (SBS) and multiple chemical sensitivity (MCS) (Ashford, 1991). SBS is said to affect otherwise healthy persons whose adverse symptoms are related to time spent in a particular building and which wane when the affected persons leave a suspected problematic indoor air environment. MCS sufferers exhibit similar symptoms, but they are not restricted to a single environment and they manifest as symptoms of continuous discomfort and illness.
Recommended publications
  • Displacement Ventilation in Action: Performance Monitoring of Demonstration Classrooms
    Displacement Ventilation in Action: Performance Monitoring of Demonstration Classrooms Charles Eley and John Arent, Architectural Energy Corporation Bradley Meister, California Energy Commission ABSTRACT Displacement ventilation (DV) can provide better acoustics, improved indoor air quality, and reduced energy use for schools and other buildings. Recent research has used CFD simulation to determine supply air requirements and predict thermal comfort. However, there is a scarcity of performance data from these systems in practice. This paper presents recent research results from a Public Interest Energy Research (PIER) funded study of the technology and its application to K-12 schools. Two demonstration classrooms were continuously monitored over a six-month period to evaluate DV’s impact on thermal comfort, indoor air quality and energy use. Each of the displacement ventilation classrooms was compared to a control classroom that used a conventional packaged rooftop unit and overhead mixing air distribution. The demonstration and control classrooms were instrumented to record room temperature, carbon dioxide concentrations, relative humidity levels, and HVAC system electricity use. Temperatures were recorded at four different heights for each of three different locations to verify that thermal stratification in the space conforms to ASHRAE standards for thermal comfort. The monitoring data shows a consistent pattern of thermal stratification in the displacement classrooms. The displacement classrooms also have a lower CO2 concentration in the occupied zone than at the ceiling return, a sign of good ventilation effectiveness. Feedback from teacher surveys of thermal comfort, indoor air quality and acoustics is testament to the benefits of displacement ventilation. The results of the demonstration classrooms will help bridge the gap between theory and practice and will be a catalyst for market adoption.
    [Show full text]
  • A Model for an Under Floor Air Distribution System
    Energy and Buildings 37 (2005) 399–409 www.elsevier.com/locate/enbuild A model for an under floor air distribution system Y.J.P. Lina,*, P.F. Lindenb aEnergy and Resources Laboratories, Industrial Technology Research Institute, Hsinchu 310, Taiwan bDepartment of Mechanical and Aerospace Engineering, University of California, 9500 Gilman Drive La Jolla, San Diego, CA 92093-0411, USA Received 15 April 2004; received in revised form 30 July 2004; accepted 31 July 2004 Abstract We present a simplified model of an underfloor air distribution (UFAD) system consisting of a single source of heat and a single cooling diffuser in a ventilated space. Laboratory experiments were carried out to simulate the flow and a model for the flow in this space is proposed. The model is based on plume theory for the heat source and a fountain model for the diffuser flow, and predicts a steady-state two-layer stratification in the room. The governing parameters are shown to be the buoyancy flux of the heat source, and the volume and momentum fluxes of the cooling diffuser. The results suggest ways to optimize UFAD design and operation. # 2004 Elsevier B.V. All rights reserved. Keywords: UFAD system; Penetrative entrainment; Turbulent plume; Turbulent fountain; Displacement ventilation; Mixing ventilation 1. Introduction Bauman and Webster [2] show that well-designed UFAD systems can provide such benefits as: The motivation for this study is to understand and model the behavior of an under floor air distribution system reduced life cycle building costs; (hereafter referred to as UFAD) in a ventilated room. This improved thermal comfort; system was first introduced in the 1950s to cool a computer improved ventilation efficiency and indoor air quality; room and is emerging as a leading ventilation system design reduced energy use; in modern commercial buildings.
    [Show full text]
  • Simplified Modelling of Displacement Ventilation
    UNIVERSIDADE DE LISBOA FACULDADE DE CIÊNCIAS Simplified Modelling of Displacement Ventilation Doutoramento em Energia e Ambiente Especialidade em Energia e Desenvolvimento Sustentável Nuno André Marques Mateus Tese orientada por: Professor Doutor Guilherme Carvalho Canhoto Carrilho da Graça Documento especialmente elaborado para a obtenção do grau de doutor 2016 UNIVERSIDADE DE LISBOA FACULDADE DE CIÊNCIAS Simplified Modelling of Displacement Ventilation Doutoramento em Energia e Ambiente Especialidade em Energia e Desenvolvimento Sustentável Nuno André Marques Mateus Tese orientada por: Professor Doutor Guilherme Carvalho Canhoto Carrilho da Graça Júri: Presidente: ● Doutor João Catalão Fernandes (Faculdade de Ciências, Universidade de Lisboa) Vogais: ● Doutor Paul Linden (Faculty of Mathematics, University of Cambridge) ● Doutor Eusébio Zeferino da Conceição (Faculdade de Ciências e Tecnologia, Universidade do Algarve) ● Doutor João Manuel de Almeida Serra (Faculdade de Ciências, Universidade de Lisboa) ● Doutor Guilherme Carvalho Canhoto Carrilho da Graça (Faculdade de Ciências, Universidade de Lisboa) ● Doutora Marta João Nunes Oliveira Panão (Faculdade de Ciências, Universidade de Lisboa) Documento especialmente elaborado para a obtenção do grau de doutor 2016 Acknowledgements This work would not have been possible without the financial support of Calouste Gulbenkian Foundation through Ph.D. Grant No. 126724. I am grateful to my supervisor professor Guilherme Carrilho da Graça, for having accepted to guide me, for all the opportunities he provided me and the challenges he put me through which allowed me to learn more than I could ever expected. To Filipa Silva, Daniel Albuquerque, António Soares and all the other students that contributed for an incredibly friendly and supportive working atmosphere in the “buildings team”. To all my friends, for the friendship and support.
    [Show full text]
  • Theoretical and Experimental Study of Combined System: Chilled Ceiling and Displacement Ventilation
    Universal Journal of Mechanical Engineering 7(3): 118-138, 2019 http://www.hrpub.org DOI: 10.13189/ujme.2019.070305 Theoretical and Experimental Study of Combined System: Chilled Ceiling and Displacement Ventilation Israa Ali AbdulGhafor1,*, Adnan A. Abdulrasool2, Qasim S. Mehdi2 1Lecturer, Department of Electronic Technique, Middle Technical University, Iraq 2Professor, Department of Mechanical Engineering, Al-Mustansiriya University, Iraq Copyright©2019 by authors, all rights reserved. Authors agree that this article remains permanently open access under the terms of the Creative Commons Attribution License 4.0 International License Abstract The present experimental study presents the obtain with using HVAC systems that supply enough of performance of the combine cooling system (chilled quantity of fresh air to the occupied zone whilst effectively ceiling and displacement ventilation). The experimental elimination contaminants. So, HVAC, systems provide study included the effect of different temperatures of suitable air temperature by elimination heat from occupied chilled ceiling of (20 and 16)°C and different supplied air zone while avoid large air temperature gradients and drafts. temperatures of (18, 20, 22 and 24)°C with constant Economic side should be achieved by both thermal and internal load of 1600W and constant supplied air velocity indoor air quality requirements, because the largest energy of 0.75m/s. The theoretical study content studying the air consumption is done by these systems. According to recent flow pattern through occupant zone and temperatures researches more than 40% of total energy used by contours in different directions X, Y and Z at supplied air commercial building is consumption by HAVC systems temperature (18)°C and internal load, mean plate [1].
    [Show full text]
  • Underfloor Air Distribution (UFAD)
    Underfloor Air Distribution Underfloor Air Distribution Introduction Underfloor Air Distribution (UFAD) is an alternative to traditional overhead air distribution that delivers air from a pressurized air plenum beneath a raised access floor, relying on the natural buoyancy of air to remove heat and contaminants. Price offers both UFAD Mixing Systems turbulent flow (mixing) and 63-65°F supply air 55°F supply air displacement flow Mixes the “occupied Mixes the entire space underfloor diffusers zone” only Stratified temperature Uniform temperature and Turbulent Flow and contaminant levels contaminant levels Displacement Flow What is stratification? Stratification refers to a non-uniform temperature throughout a zone, with higher temperatures towards the ceiling and lower temperatures towards the floor. In a stratified room, return air is warmer and has a higher level of contaminants than supply air does. What is the occupied zone? Displacement diffusers result in more The occupied zone refers to the space in a room that begins one pronounced stratification and lower velocity profiles in the room, often foot from all walls and extends from the floor to six feet above the leading to improved indoor air quality floor. Mixing the occupied zone instead of the whole space can and thermal comfort. result in energy savings in spaces with high ceilings. 2 priceindustries.com Advantages Flexibility Diffusers installed in a raised floor can be reconfigured at a fraction of the time and cost of an overhead system. Given the prevalence of churn in a modern office environment, a highly configurable HVAC system can be a great cost savings in these environments.
    [Show full text]
  • Displacement Ventilation Provides Cornerstone of Hospital Design
    ASHRAE TECHNOLOGY AWARD CASE STUDIES 2020 ©ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal at https://www.mazzetti.com. This article may not be copied nor distributed in either paper or digital form without ASHRAE’s permission. For more information about ASHRAE, visit www.ashrae.org. Displacement Ventilation Provides Cornerstone of Hospital Design The project uses displacement ventilation in the structural columns in the lobby, patient rooms and the intensive care unit. BY BRIAN HANS, P.E.; JOHN PAPPAS, P.E., MEMBER ASHRAE 38 ASHRAE JOURNAL ashrae.org OCTOBER 2020 HONORABLE MENTION | 2020 ASHRAE TECHNOLOGY AWARD CASE STUDIES Displacement ventilation was incorporated into the lobby’s structural columns to seam- lessly integrate the mechanical systems and T he overarching goal for the Lucile provide efficient air distribution, reducing energy consumption and improving Packard Children’s Hospital (Packard occupant comfort. Children’s) was to create an environment that aids healing by providing children and expectant mothers and their visi- tors warm, comfortable, light-filled and uplifting spaces, creating a “home away from home.” The project embodies inno- vation and a true commitment to envi- ronmental sustainability. Displacement ventilation was a cornerstone system decision to achieving the project’s energy- efficiency goals. The new 521,000 net square feet (48 402 square meter) building sits atop a 192,000 square foot (17 837 square meter) garage, more than doubling the size of the exist- ing pediatric and obstetrics hospital campus. The new building adds 149 patient beds for a total of 364 patient beds on the Palo Alto campus. It includes four floors con- sisting of two wings of ICU and acute care unit patient care beds, 12 operating/interventional radiology rooms, a full imaging area that includes MRI, CT and PET/CT, a grand light-filled lobby, public areas, and 3.5 acres (1.4 ha) of green space with gardens and artwork for patients, family and staff.
    [Show full text]
  • Thermal Displacement Ventilation (TDV) in Schools: Improving Indoor Air Quality and Saving Energy
    Thermal Displacement Ventilation (TDV) in Schools: Improving Indoor Air Quality and Saving Energy Andrey Livchak, Halton Company Charles Eley, Architectural Energy Corporation Zeqiang Sun, Halton Company John Arent, Architectural Energy Corporation Vern Smith, Architectural Energy Corporation ABSTRACT Thermal displacement ventilation (TDV) is a promising technology for schools and other buildings. The potential energy efficiency, health, and acoustic benefits offer promise as California and other states prepare to spend billions on new schools and major modernization. This paper presents some results from a PIER-funded study of the technology evaluated with computational fluid dynamics and full-scale model testing. In 1995, the Government Accounting Office concluded that 25% of the nation’s schools are plagued by indoor air quality (IAQ) problems. A few years later the Environmental Protection Agency (Johnston & Davis 2001) reported an even higher percentage of schools having IAQ problems. Most of these IAQ problems can be attributed to poor ventilation. TDV, which has been used since the late 1980s in Northern Europe and only more recently in U.S. schools (Turner 1999; Holland & Livchak 2002), disproves the common perception that improving IAQ in an air-conditioned space must result in higher energy consumption. What Is It? Most classroom air conditioning systems use overhead mixing ventilation to deliver cool air (about 55ºF) at the ceiling level. Air is supplied at a high velocity to provide efficient mixing of supply air with room air, to provide uniform temperature throughout the space, and to dilute contaminants with fresh supply air. This system of ventilation has several drawbacks: it can circulate germs, promoting exposure to illness, and it can be noisy and/or drafty – the high-speed air can whistle as it leaves the diffuser, creating possible drafts and making it harder for the students to hear the teacher.
    [Show full text]
  • Estimating Performance of Thermal Displacement Hvac Systems Using Heat Balance-Based Simulation Programs
    Eighth International IBPSA Conference Eindhoven, Netherlands August 11-14, 2003 ESTIMATING PERFORMANCE OF THERMAL DISPLACEMENT HVAC SYSTEMS USING HEAT BALANCE-BASED SIMULATION PROGRAMS Thomas A. Lunneberg, P.E. CTG Energetics, Inc. Irvine, California 92618 United States of America ABSTRACT The use of thermal displacement systems in the This paper will address the shortcomings of typical United States, however, is still in its infancy. Driven heat balance-based HVAC design and analysis in large part by increasing emphasis on sustainable software when applied to thermal displacement design practices and an impetus to provide healthier ventilation (TDV) system design. The performance indoor environments, many owners and developers characteristics of thermal displacement systems that are asking their engineers to design TDV systems for lead to inaccurate calculations from heat balance- their new buildings. Unfortunately, many U.S. based programs are discussed. Finally, the paper engineers and architects have little experience with presents an approach for estimating the performance the design and analysis of thermal displacement of TDV systems using existing heat-based calculation systems. As a result, many approach this task from tools that responds to most of the significant an incorrect perspective – namely, that the thermal differences between overhead mixing systems and behavior of a displacement system is similar to that thermal displacement systems. of a traditional overhead “mixing” system. The result is that poorly designed systems are being INTRODUCTION introduced into the marketplace. Such systems tend Thermal displacement ventilation (TDV) systems – to deliver too much supply air, do not adequately essentially, HVAC air distribution systems that address dehumidification needs, and frequently have supply conditioned air at or near the floor and extract overly complex control systems.
    [Show full text]
  • The Fluid Mechanics of Natural Ventilation-Displacement Ventilation by Buoyancy-Driven Flows Assisted by Wind G.R
    AIVC 12,435 PERGAMON Building and Em·ironment 34 ( 1999) 707-710 -- The fluid mechanics of natural ventilation-displacement ventilation by buoyancy-driven flows assisted by wind G.R. Hunt*, P.F. Linden Depanme111 oj Applied .Hatlil'111a1ics Theol'<'li('llf Phi-sics. L"11ireni1r(}(Camhridge. Silrer Street. Ca111hriclg<'. CBJ 9EW. L'.K. mu/ Abstract This paper describes the fluid mechanics of natural ventilation by the combined effects of buoyancy and wind. Attention is restricted to transient draining flows in a space containing buoyant fluid. when the wind and buoyancy forces rei11/(Jrc<' one another. The flows have been studied theoretically and the results compared with small-scale laboratory experiments. Connections between the enclosure and the surrounding fluid are with high-level and low-level openings on both windward and leeward faces. Dense fluid enters through \\indward openings at low levt:ls and displaces the lighter fluid within the enclosure through high-level. leeward openings. A strong. stable stratification develops in this case and a displacement flow is maintained for a range of Froude numbers. The rate at which the enclosure drains increases as the wind-induced pressure drop between the inlet and outlet is increased and as the density difference between the exterior and interior environment is increased. A major result of this work is the identification of the form of the nonlinear relationship between the buoyancy and wind effects. It is shown that there is a Pythagorean relationship between the combined buoyancy and wind-driven velocity and the velocities which are produced by buoyancy and wind forces acting in isolation.
    [Show full text]
  • Displacement Ventilation
    Displacement Ventilation Risto Kosonen (ed.) Arsen Melikov Elisabeth Mundt Panu Mustakallio Peter V. Nielsen rehva Federation of European Heating, Ventilation and Air Conditioning Associations GUIDEBOOK NO 23 Single user license only, copying and networking prohibited. All rights reserved by REHVA. Single user license only, copying and networking prohibited. All rights reserved by REHVA. REHVA Displacement Ventilation Risto Kosonen (ed.) Arsen Melikov Elisabeth Mundt Panu Mustakallio Peter V. Nielsen Single user license only, copying and networking prohibited. All rights reserved by REHVA. DISCLAIMER This Guidebook is the result of the efforts of REHVA volunteers. It has been written with care, using the best available information and the soundest judgment possible. REHVA and its volunteers, who contributed to this Guidebook, make no representation or warranty, expressed or implied, concerning the completeness, accuracy, or applicability of the infor- mation contained in the Guidebook. No liability of any kind shall be assumed by REHVA or the authors of this Guidebook as a result of reliance on any information contained in this document. The user shall assume the entire risk of the use of any and all information in this Guidebook. ----------------------------------------------------------------------------------------------------------- Copyright © 2017 by REHVA REHVA is the Federation of European Heating, Ventilation and Air Conditioning Associations, www.rehva.eu All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopies or any other information storage and re- trieval system, without permission in writing from the publisher. Requests for permission to make copies of any part of the work should be addressed to: REHVA Office, 40 Rue Washington, 1050 Brussels – Belgium e-mail: [email protected] ISBN 978-2-930521-17-6 Printed in Finland, Forssan Kirjapaino Oy, Forssa Single user license only, copying and networking prohibited.
    [Show full text]
  • On the Natural Displacement Ventilation Flow Through a Full Scale Enclosure, Driven by a Source of Buoyancy at Floor Level S
    Seventh International IBPSA Conference Rio de Janeiro, Brazil August 13-15, 2001 ON THE NATURAL DISPLACEMENT VENTILATION FLOW THROUGH A FULL SCALE ENCLOSURE, DRIVEN BY A SOURCE OF BUOYANCY AT FLOOR LEVEL S. A. Howell and I. Potts University of Newcastle upon Tyne Newcastle upon Tyne, NE1 7RU, England technique, which uses salt water to generate density ABSTRACT differences and motivate the displacement flow. This paper presents experimental data for the This paper reports independent validation work, temperature stratification established within a where a natural displacement ventilation flow, driven full-scale enclosure, for the natural displacement by a source of buoyancy at floor level, is established ventilation flow driven by a source of buoyancy at within a full-sized enclosure with air as the working floor level within the space with air as the working fluid. This is an extension of previously published fluid. work (Howell and Potts, 1998), where a smaller scale A range of predictive techniques is also enclosure was studied. The current investigation is, investigated for the flow, and for each technique a however, truly representative of the ventilation flows critical comparison with the experimental data is observed in real buildings. presented. It is found that there are differences between It is confirmed that the salt-bath modelling the ventilation flow through the full-scale test room technique and related mathematical model of Linden and that predicted by the simple mathematical et, al. (1990) is not appropriate for the prediction of models for the steady-state case. The causes of the this type of ventilation flow in full-scale buildings.
    [Show full text]
  • Chilled Beam Technology
    Modern HVAC-systems for nearly zero energy buildings Maija Virta M.Sc.(Eng.) Head of Operations, Santrupti engineers Fellow of REHVA,Member of ASHRAE Federation of European Heating, Ventilation and Air-conditioning Associations 1 Technologies Used in Zero Energy Buildings • Reduced Energy Need • Reduced System Energy Use – Active and passive beams – DOAS – Chilled ceilings and TABS • Energy recovery • Dehumidification – Radiant floor cooling (&heating) • Adiabatic & desiccant cooling – Displacement ventilation – Evaporative cooling – UFAD (under floor air diffusion) – Demand based ventilation – Natural and hybrid ventilation – Earth tubes – Night purge ventilation – Condensing boilers – Personal ventilation • On-site Energy Production – Active solar shading – District heating and cooling – LED lighting – Heat pumps – Light tubes (daylight) – Solar heat – BMS – Solar cooling Focus of this presentation is on – Photovoltaic (PV) underlined HVAC technologies – Wind turbines Federation of European Heating, Ventilation and Air-conditioning Associations 2 Passive Chilled Beams Federation of European Heating, Ventilation and Air-conditioning Associations 3 Main Principles of Passive Chilled Beam • Passive chilled beams comprise a heat exchanger for cooling, and when desired for heating. • The operation is based on natural convection. • The primary air is supplied to the space using separate diffusers either in the ceiling or wall, low velocity units at low level or alternatively through the raised floor. Federation of European Heating, Ventilation and Air-conditioning Associations 4 Active Chilled Beams Federation of European Heating, Ventilation and Air-conditioning Associations 5 Chilled Beam Operation 1. Primary air (dehumidificated outdoor air) supply into supply air chamber 2. Primary air is supplied through small nozzles. 4 3. Primary air supply induces room air to be re-circulated through the heat exchanger of the chilled beam.
    [Show full text]