Static and Dynamic Components of Right Ventricular Afterload Are Negatively Associated with Calf Survival at High Altitude1

Total Page:16

File Type:pdf, Size:1020Kb

Static and Dynamic Components of Right Ventricular Afterload Are Negatively Associated with Calf Survival at High Altitude1 Published September 29, 2016 Static and dynamic components of right ventricular afterload are negatively associated with calf survival at high altitude1 J. M. Neary,*2 R. D. Brown,† T. N. Holt,‡ K. R. Stenmark,† R. M. Enns,§ M. G. Thomas,§ and F. B. Garry‡ *Department of Animal and Food Sciences, College of Agricultural Sciences and Natural Resources, Texas Tech University, Lubbock 79409-2141; †Division of Pediatric Critical Care, School of Medicine, University of Colorado Denver, Aurora 80045; ‡Integrated Livestock Management, Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, 1678 Campus Delivery, Fort Collins 80523-1678; and, §Department of Animal Sciences, The College of Agricultural Sciences, Colorado State University, Fort Collins 80523-1171. ABSTRACT: The purposes of this study were to pulse pressures (P = 0.03) at 3 mo of age than calves evaluate mean, systolic, and diastolic pulmonary that survived to 7 mo. Calves presumed to have died arterial pressures; pulmonary arterial pulse pres- tended to have greater systemic oxygen extraction sures; and systemic oxygen extraction fraction as fractions at 3 mo of age than calves that survived (P risk factors for the survival of suckling calves on one = 0.13). Diastolic pressure was not associated with ranch located at an altitude of 2,730 m in Colorado, survival (P = 0.27). Mean pulmonary arterial pres- USA. A prospective cohort study of 58 calves was sure is predominantly determined by static resistance performed. Pulmonary arterial pressures and sys- attributable to distal pulmonary arterial remodeling. temic oxygen extraction were measured when calves Pulse pressure and systolic pulmonary arterial pres- were approximately 3 mo (86 ± 7 d) and 7 mo (197 sure represents the dynamic or oscillatory resistance ± 6 d) of age. Seven of the 58 calves (12%), 4 steers and is determined by the characteristics of ventricu- and 3 heifers, were unaccounted for and presumed lar ejection and proximal arterial stiffness. These dead between 3 and 7 mo of age. Calves presumed findings indicate that it may be beneficial to include to have died between 3 and 7 mo of age had sig- pressure measurements indicative of both static and nificantly greater mean (P = 0.005) and systolic (P dynamic pulmonary arterial resistance in the selec- = 0.001) pulmonary arterial pressures and greater tion of breeding stock at high altitude. © 2016 American Society of Animal Science. All rights reserved. J. Anim. Sci. 2016.94 doi:10.2527/jas2016-0652 INTRODUCTION is a leading cause of suckling calf death loss among ranches at altitudes over 2,400 m (Neary et al., 2013). Right-sided congestive heart failure (RHF) sec- The susceptibility of cattle (Bos taurus) to hypoxia- ondary to pulmonary hypertension, or cor pulmonale, induced pulmonary hypertension has been attributed to their highly muscular small pulmonary arteries that vasoconstrict and remodel in response to hypoxia (Al- 1Funding for the study was provided by producer donations to exander and Jensen, 1963a,b; Tucker et al., 1975). the Integrated Livestock. Management program of the College of Because mean pulmonary arterial pressure Veterinary and Biomedical Sciences, Colorado State University; (mPAP) is moderately heritable (Shirley et al., 2008; the Department of Animal Science’s John E. Rouse Endowment, Newman et al., 2015), producers at high altitudes Colorado State University; and, the National Institutes of Health (> 2000 m) commonly screen their breeding stock (HL-014985, to KRS). The content is solely the responsibility of to identify individuals with high mPAP—typically the authors. The authors have no conflicts of interest to declare. 45 mmHg—and remove them from the herd (Holt 2Corresponding author: [email protected] and Callan, 2007). This strategy is thought to reduce Received May 20, 2016. Accepted July 15, 2016. the incidence of RHF because cattle with mPAP ◊ ◊ Neary et al. 45 mmHg are considered to be at increased risk of at an altitude of 2,410 m. At 2 mo of age, they were RHF (Holt and Callan, 2007). Although the prognos- moved to new pastures at an altitude of 2,730m. From tic value of PAP measurement has been validated in 4 to 7 mo of age, calves had access to pastures ranging other species (Ghio et al., 2001), it has not been deter- in altitude from 2,730 m to approximately 3,500 m. mined in cattle. Further, to our knowledge, there has Calves were sampled twice at approximately 3 mo (86 been no scientific validation that the identification and ± 7 d) and 7 mo (197 ± 6 d) of age. Every second calf removal of individuals with mPAP 45 mmHg from into the chute was sampled. Fifty-one of the 58 calves the breeding stock will reduce the incidence of RHF sampled at 3 mo of age survived to 7 mo of age and in the calf crop. Therefore, it is important to define the were resampled. utility of mPAP to predict calf survival. The dams were given prebreeding and precalving To date, selection strategies to reduce calf death vaccinations offering protection against viral agents loss from RHF have focused on mPAP, reflecting the of respiratory disease. Calves were vaccinated against static resistance to ventricular afterload attributable to the same respiratory pathogens at 4 to 8 wk of age and distal pulmonary arterial remodeling (Alexander and 2 to 4 wk before weaning. All calves were sired by Jensen, 1963a,b; Holt and Callan, 2007). By contrast, bulls with a mPAP < 42 mmHg at 2,440 m. A hormonal the dynamic, pulsatile component of pulmonary ar- growth promotant (Synovex C; Zoetis, Madison, NJ) terial blood flow has largely been ignored; however, containing 100 mg progesterone and 10 mg estradiol more recent evidence from human studies suggests benzoate was administered to all calves in the herd that disturbed flow pulsatility arising from pulmonary at 2,730 m when approximately 8 wk old. All calves arterial stiffening may contribute to the development were clinically healthy when sampled at 3 mo of age. of RHF (Schäfer et al., 2016). If so, indirect measures The Colorado State University Animal Care and Use of pulmonary arterial stiffening, such as systolic pul- Committee approved the study before any animals monary arterial pressure (sPAP) and pulmonary arte- were sampled (protocol 09–1524A). rial pulse pressure, may also serve as valuable indica- tors of RHF susceptibility in cattle. Pulmonary Arterial Pressure (PAP) Testing It has also been suggested that the small cardio- pulmonary system of domestic cattle relative to body Holt and Callan (2007) provide a full description of size and oxygen requirements is a risk factor for RHF the equipment, materials, and facilities required for PAP (Veit and Farrell, 1978). A reduction in the rate of testing. In brief, saline-filled, polyethylene catheter tub- oxygen delivery relative to metabolic demand would ing (external and internal diameter of 17 and 12 mm, re- manifest physiologically as an increased systemic spectively) was fed through a 12-gauge, 8.9-cm needle oxygen extraction fraction (sOEF), that is, the propor- that was inserted into the jugular vein. The position of tion of oxygen within arterial blood that is extracted the catheter tip within the vascular system was deter- by the peripheral tissues (McLellan and Walsh, 2004). mined from the pressure waveform on the oscilloscope If the rate of oxygen delivery is reduced, sOEF must (BM5Vet; Bionet America, Inc., Tustin, CA). The jugu- increase to maintain aerobic metabolism at steady lar vein, right atrium, right ventricle, and pulmonary ar- state. Consequently, calves that have a high sOEF (> tery have distinct pressure waveforms (Holt and Callan, 0.30) may be at greater risk of decompensated heart 2007). Once inside the pulmonary artery, mean, systolic, failure and death because they have less physiological and diastolic pressures were recorded after the pressure reserve to respond to the increased cardiac workload waveforms stabilized. Pulse pressure was calculated as associated with increasing mPAP. the absolute difference between systolic and diastolic The purposes of this study were to evaluate mean, pressures. Calves were moved to a small pen enclosure systolic, diastolic pulmonary arterial pressures, pulmo- for at least 20 min before sampling. nary arterial pulse pressures, and sOEF as risk factors for the survival of suckling calves to 7 mo of age on 1 ranch Blood-Gas Analyses located at an altitude of 2,730 m in Colorado, USA. Approximately, 2.5 mL of blood aliquots of arte- MATERIALS AND METHODS rial and mixed venous blood were collected in 3-mL syringes. Arterial blood was collected from the coc- Study Site and Cattle cygeal artery using a 22-gauge, 2.54-cm (1”) hypoder- The 58 calves (30 heifers and 28 steers) included mic needle. The bovine coccygeal artery is a suitable in the study were a composite of Red Angus, Hereford, source for blood-gas analysis (Collie, 1991; Nagy et Gelbvieh, and Simmental breeds. Calves were born to al., 2002). Mixed venous blood was collected via the primiparous heifers on a commercial cow-calf ranch catheter used for pulmonary arterial pressure mea- Pulmonary arterial pressure and calf survival ◊ surement. Syringes used for arterial blood gas collec- version 12; Stata Corporation, College Station, TX). tion were heparinized with approximately 0.25 mL of Only 7 of the 58 calves in the cohort were presumed to sodium heparin (1,000 IU/ml). The plunger of each have died; consequently, median values are provided syringe was pulled back to the 3-mL mark coating the as measures of central tendency. Further, Mann–Whit- inner chamber surface with heparin. Heparin was then ney U tests were used to determine if the pulmonary expelled so that only the needle hub contained heparin. arterial pressures or sOEF of the 3 mo old calves dif- The sample was discarded if during collection the flow fered according to 7 mo survival status.
Recommended publications
  • Hemodynamic Monitoring and Circulatory Assist Devices
    Hemodynamic Monitoring Hemodynamic Monitoring and Circulatory Assist Devices • Measurement of pressure, flow, and oxygenation within the cardiovascular system • Includes invasive and noninvasive measurements (Relates to Chapter 66, – Systemic and pulmonary arterial pressures “Nursing Management: Critical Care,” in the textbook) Hemodynamic Monitoring Hemodynamic Monitoring • Invasive and noninvasive measurements • Invasive and noninvasive measurements (cont’d) (cont’d) – Central venous pressure (CVP) – Stroke volume (SV)/stroke volume index (SVI) – Pulmonary artery wedge pressure (PAWP) – O2 saturation of arterial blood (SaO2) – Cardiac output (CO)/cardiac index (CI) – O2 saturation of mixed venous blood (SvO2) Hemodynamic Monitoring Hemodynamic Monitoring General Principles General Principles • Preload: Volume of blood within ventricle at • Contractility: Strength of ventricular end of diastole contraction • Afterload: Forces opposing ventricular • PAWP: Measurement of pulmonary capillary ejection pressure; reflects left ventricular end‐diastolic – Systemic arterial pressure pressure under normal conditions – Resistance offered by aortic valve – Mass and density of blood to be moved 1 Hemodynamic Monitoring Principles of Invasive Pressure General Principles Monitoring • CVP: Right ventricular preload or right • Equipment must be referenced and zero ventricular end‐diastolic pressure under balance to environment and dynamic normal conditions, measured in right atrium response characteristics optimized or in vena cava close to heart •
    [Show full text]
  • Effect of Isoproterenol, Phenylephrine, and Sodium Nitroprusside on Fundus Pulsations in Healthy Volunteers
    British Journal of Ophthalmology 1996; 80: 217-223 217 Effect of isoproterenol, phenylephrine, and sodium nitroprusside on fundus pulsations in Br J Ophthalmol: first published as 10.1136/bjo.80.3.217 on 1 March 1996. Downloaded from healthy volunteers Leopold Schmetterer, Michael Wolzt, Alex Salomon, Alexander Rheinberger, Christian Unfried, Gabriele Zanaschka, Adolf Friedrich Fercher Abstract have not yet been carried out and quantitative Aims/Background-Recently a laser inter- pressure flow relations in human choroidal ferometric method for topical measure- vessels are as yet unknown. Linear choroidal ment of fundus pulsations has been pressure flow relations have been obtained in developed. Fundus pulsations in the macu- animal experiments in different species.5-8 In lar region are caused by the inflow and out- the rabbit, the choroidal blood flow has been flow ofblood into the choroid. The purpose shown to be pressure independent when IOP ofthis work was to study the influence of a was less than 20-25 mm Hg.9 peripheral vasoconstricting (the a,x adreno- Blood vessels can be considered as cylin- ceptor agonist phenylephrine), a predomi- ders filled with fluid at a pressure greater than nantly positive inotropic (the non-specific that outside the cylinders. The pressure dif- I adrenoceptor agonist isoproterenol), and ference between the inside and the outside of a non-specific vasodilating (sodium nitro- a vessel is called the transmural pressure P. prusside) model drug on ocular fundus The corresponding tension T in the vessel pulsations to determine reproducibility wall can be calculated by Laplace's law and sensitivity ofthe method. P=T/R, where R is the radius of the cylinder.
    [Show full text]
  • Time-Varying Elastance and Left Ventricular Aortic Coupling Keith R
    Walley Critical Care (2016) 20:270 DOI 10.1186/s13054-016-1439-6 REVIEW Open Access Left ventricular function: time-varying elastance and left ventricular aortic coupling Keith R. Walley Abstract heart must have special characteristics that allow it to respond appropriately and deliver necessary blood flow Many aspects of left ventricular function are explained and oxygen, even though flow is regulated from outside by considering ventricular pressure–volume characteristics. the heart. Contractility is best measured by the slope, Emax, of the To understand these special cardiac characteristics we end-systolic pressure–volume relationship. Ventricular start with ventricular function curves and show how systole is usefully characterized by a time-varying these curves are generated by underlying ventricular elastance (ΔP/ΔV). An extended area, the pressure– pressure–volume characteristics. Understanding ventricu- volume area, subtended by the ventricular pressure– lar function from a pressure–volume perspective leads to volume loop (useful mechanical work) and the ESPVR consideration of concepts such as time-varying ventricular (energy expended without mechanical work), is linearly elastance and the connection between the work of the related to myocardial oxygen consumption per beat. heart during a cardiac cycle and myocardial oxygen con- For energetically efficient systolic ejection ventricular sumption. Connection of the heart to the arterial circula- elastance should be, and is, matched to aortic elastance. tion is then considered. Diastole and the connection of Without matching, the fraction of energy expended the heart to the venous circulation is considered in an ab- without mechanical work increases and energy is lost breviated form as these relationships, which define how during ejection across the aortic valve.
    [Show full text]
  • Left Ventricular Assist Device
    Left Ventricular Assist Device PHI 2016 Objectives • Discuss conditions to qualify for LVAD Therapy • Discuss LVAD placement and other treatment modalities • Describe the Thoratec Heartmate 2 and Heartmate 3 systems • Discuss assessment changes of the LVAD patient • Review emergency care of the LVAD patient Stage C or D Heart Failure slide 3 LVAD Exclusion Criteria • Aortic Valve Competency – Sometimes valve is oversewn to allow adequate device function • RV Function- if RV dysfunction is present must be transplant candidate – No PPHTN unless candidate for heart-lung transplant • Hepatic Dysfunction- cirrhosis and portal HTN • Renal Dysfunction- Irreversible disease vs. disease due to poor perfusion – Long term dialysis and creatinine > 3.0 mg/dl • Cancer • Psych/Social Concerns slide 4 LVAD Referral • Symptoms • Hypotension – Recurrent admissions • Laboratory – Refractory • Renal insufficiency – At rest • Hepatic dysfunction • Medications • Hyponatremia – Intolerance or lower doses • Pulmonary Hypertension • ACE-I/ARBs • RV Dysfunction • Beta blockers • Unresponsiveness to CRT – Increasing diuretic doses (Cardiac Resynchronization Therapy) • Unable to carry out ADLs – Poor nutritional status • Inotropes slide 5 INTERMACS Classification slide 9 LVAD Implantation Process • Referral Phase – Referred to AHFC by primary cardiologist • Evaluation Phase (2-4 weeks) – Testing – Consults with each team member – Selection Committee meets weekly • Surgery Phase (~4-6 weeks) – Admit to CCU the day before surgery • Outpatient Phase – Weekly clinic
    [Show full text]
  • Increased Pulse Pressure Is Associated with Reduced Baroreflex Sensitivity
    Journal of Human Hypertension (2004) 18, 247–252 & 2004 Nature Publishing Group All rights reserved 0950-9240/04 $25.00 www.nature.com/jhh ORIGINAL ARTICLE Increased pulse pressure is associated with reduced baroreflex sensitivity R Virtanen1, A Jula2, H Huikuri3, T Kuusela4, H Helenius5, A Ylitalo6, L-M Voipio-Pulkki1,7, H Kauma3,8, YA Kesa¨niemi3,8 and J Airaksinen1 1Department of Medicine, University of Turku, Turku, Finland; 2Research Department of the Social Insurance Institution, Turku, Finland; 3Department of Medicine, University of Oulu, Oulu, Finland; 4Department of Physics, University of Turku, Turku, Finland; 5Department of Biostatistics, University of Turku, Turku, Finland; 6Division of Cardiology, Satakunta Central Hospital, Pori, Finland; 7Department of Medicine, Helsinki University Central Hospital, Helsinki, Finland; 8Biocenter Oulu, University of Oulu, Oulu, Finland Although pulse pressure (PP), heart rate variability significant when 24-h ambulatory diastolic blood pres- (HRV) and baroreflex sensitivity (BRS) have been shown sure, body mass index, smoking and alcohol intake were to predict cardiovascular events and mortality in various added as covariates in the multivariate analysis. In- populations, their relationships have not been clarified. creased ambulatory PP was also associated with We examined these associations in two separate increased beat-to-beat systolic arterial pressure varia- population-based samples of healthy middle-aged sub- bility. Associations between ambulatory PP and HRV jects. In population 1, data were obtained from 149 were not significant after controlling for age and gender. subjects (71 men and 78 women) aged 35–64 (mean 47.7) Our results suggest that elevated PP does not affect years, and in population 2, from 214 subjects (88 men overall HRV, but it interferes with baroreflex-mediated and 126 women) aged 40–62 (mean 50.5) years.
    [Show full text]
  • Pulse and Blood Pressure Procedures Manual
    NATIONAL HEALTH AND NUTRITION EXAMINATION SURVEY III CYCLE 2 PULSE AND BLOOD PRESSURE PROCEDURES FOR HOUSEHOLD INTERVIEWERS Prepared by: Westat, Inc. 1650 Research Boulevard Rockville, MD 20850 September 1989 Revised July 1993 TABLE OF CONTENTS Chapter Page 1 PULSE AND BLOOD PRESSURE PROCEDURES....................................... 1-1 1.1 Introduction to Pulse and Blood Pressure............................................. 1-1 1.2 Background on Pulse and Blood Pressure............................................ 1-1 1.2.1 The Circulatory System ........................................................... 1-1 1.2.2 Definition of Pulse ................................................................... 1-3 1.2.3 Definition of Blood Pressure................................................... 1-3 1.2.4 Meaning of Blood Pressure..................................................... 1-3 1.2.5 Method of Measuring Arterial Blood Pressure.......................................................................... 1-4 2 DESCRIPTION AND MAINTENANCE OF BLOOD PRESSURE EQUIPMENT ................................................................................. 2-1 2.1 Blood Pressure Equipment..................................................................... 2-1 2.1.1 Manometer................................................................................ 2-1 2.1.2 Inflation System........................................................................ 2-5 2.1.3 Stethoscope..............................................................................
    [Show full text]
  • Quantitative Electrocardiography for Prediction Of
    QUANTITATIVE ELECTROCARDIOGRAPHY FOR PREDICTION OF POSTOPERATIVE ATRIAL FIBRILLATION AFTER CARDIAC SURGERY by FLORIAN RADER, M.D. Submitted in partial fulfillment of the requirements For the degree of Master of Science Clinical Research Scholars Program CASE WESTERN RESERVE UNIVERSITY January 2010 CASE WESTERN RESERVE UNIVERSITY SCHOOL OF GRADUATE STUDIES We hereby approve the thesis/dissertation of Florian Rader, M.D. candidate for the Master of Science degree*. (signed) Regis E. McFadden (chair of the committee) Eugene H. Blackstone, M.D. Ottorino Costantini, M.D. Neal Dawson, M.D. (date) 10-28-2009 *We also certify that written approval has been obtained for any proprietary material contained therein. 2 Table of Contents List of Tables 4 List of Figures 5 Acknowledgments 6 List of Abbreviations 7 Abstract 9 Text Background and Significance 10 Specific aims 12 Methods 13 Results 21 Discussion 46 Limitations 54 Conclusions 54 References 55 3 List of Tables: Table 1: Patient characteristics 24 Table 2: Clinical predictors of postoperative atrial fibrillation 37 Table 3: ECG predictors of postoperative atrial fibrillation 38 4 List of Figures: Figure 1: Relationship of anatomic and ECG changes with POAF 11 Figure 2: Patient flow chart 22 Figure 3: Occurrence of POAF by days after surgery 33 Figure 4: Occurrence of POAF by surgery type 34 Figure 5: ROC curve of final prediction model 35 Figure 6: Calibration curve of final prediction model 36 Figure 7: Adjusted Co-plots of ECG predictors 39 Figure 8: Unadjusted and adjusted co-plot of P wave amplitude 41 Figure 9: Nomogram of final prediction model 42 Figure 10: Nomogram of prediction model with pre-op variables 43 Figure 11: Calibration curve of model without ECG predictors 45 Figure 12: Left atrial sizes by P wave amplitude in aVR 48 Figure 13: Correlation matrix (P wave amplitude, aVR, and left atrial volume) 49 5 Acknowledgments: I thank Dr.
    [Show full text]
  • Chapter 9 Monitoring of the Heart and Vascular System
    Chapter 9 Monitoring of the Heart and Vascular System David L. Reich, MD • Alexander J. Mittnacht, MD • Martin J. London, MD • Joel A. Kaplan, MD Hemodynamic Monitoring Cardiac Output Monitoring Arterial Pressure Monitoring Indicator Dilution Arterial Cannulation Sites Analysis and Interpretation Indications of Hemodynamic Data Insertion Techniques Systemic and Pulmonary Vascular Resistances Central Venous Pressure Monitoring Frank-Starling Relationships Indications Monitoring Coronary Perfusion Complications Electrocardiography Pulmonary Arterial Pressure Monitoring Lead Systems Placement of the Pulmonary Artery Catheter Detection of Myocardial Ischemia Indications Intraoperative Lead Systems Complications Arrhythmia and Pacemaker Detection Pacing Catheters Mixed Venous Oxygen Saturation Catheters Summary References HEMODYNAMIC MONITORING For patients with severe cardiovascular disease and those undergoing surgery associ- ated with rapid hemodynamic changes, adequate hemodynamic monitoring should be available at all times. With the ability to measure and record almost all vital physi- ologic parameters, the development of acute hemodynamic changes may be observed and corrective action may be taken in an attempt to correct adverse hemodynamics and improve outcome. Although outcome changes are difficult to prove, it is a rea- sonable assumption that appropriate hemodynamic monitoring should reduce the incidence of major cardiovascular complications. This is based on the presumption that the data obtained from these monitors are interpreted correctly and that thera- peutic decisions are implemented in a timely fashion. Many devices are available to monitor the cardiovascular system. These devices range from those that are completely noninvasive, such as the blood pressure (BP) cuff and ECG, to those that are extremely invasive, such as the pulmonary artery (PA) catheter. To make the best use of invasive monitors, the potential benefits to be gained from the information must outweigh the potential complications.
    [Show full text]
  • Monitoring of the Central Blood Pressure Waveform Via a Conformal Ultrasonic Device
    HHS Public Access Author manuscript Author ManuscriptAuthor Manuscript Author Nat Biomed Manuscript Author Eng. Author Manuscript Author manuscript; available in PMC 2019 March 21. Published in final edited form as: Nat Biomed Eng. 2018 September ; 2(9): 687–695. doi:10.1038/s41551-018-0287-x. Monitoring of the central blood pressure waveform via a conformal ultrasonic device Chonghe Wang#1, Xiaoshi Li#2, Hongjie Hu#2, Lin Zhang1, Zhenlong Huang1, Muyang Lin7, Zhuorui Zhang1, Zhenan Yin3, Brady Huang5, Hua Gong1, Shubha Bhaskaran3, Yue Gu2, Mitsutoshi Makihata6, Yuxuan Guo1, Yusheng Lei1, Yimu Chen1, Chunfeng Wang8, Yang Li1, Tianjiao Zhang1, Zeyu Chen4, Albert Pisano6, Liangfang Zhang1, Qifa Zhou4, and Sheng Xu1,2,3,9,* 1Department of Nanoengineering, University of California San Diego, La Jolla, CA, 92093-0448, USA. 2Materials Science and Engineering Program, University of California San Diego, La Jolla, CA, 92093-0418, USA. 3Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, 92093-0407, USA. 4Department of Ophthalmology and Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA 90089-1111, USA. 5Department of Radiology, School of Medicine, University of California San Diego, La Jolla, CA, 92103, USA. 6Department of Mechanical and Aerospace Engineering, University of California San Diego, La Jolla, CA, 92093-0411, USA. 7School of Precision Instrument and Optoelectronic Engineering, Tianjin University, Tianjin, 300072, China. 8The Key Laboratory of Materials Processing and Mold of Ministry of Education, School of Materials Science and Engineering, School of Physics & Engineering, Zhengzhou University, Zhengzhou, 450001, Henan, China. 9Department of Bioengineering, University of California San Diego, La Jolla, CA, 92093-0412, USA.
    [Show full text]
  • Wide Pulse Pressure and Quincke's Pulse in High-Output Heart Failure
    Case report BMJ Case Rep: first published as 10.1136/bcr-2021-241654 on 22 July 2021. Downloaded from Wide pulse pressure and Quincke’s pulse in high- output heart failure Katie Lin Berry,1 Peter D Sullivan,2 André Martin Mansoor 2 1School of Medicine, Oregon SUMMARY progressive exertional dyspnoea and weight gain. The Health & Science University, A 74-year -old man with a history of chronic alcohol use patient reported drinking three to four glasses of wine Portland, Oregon, USA 2 presented with progressive exertional dyspnoea and daily for at least 10 years. Physical examination was Department of Medicine, weight gain. On physical examination, he was noted notable for a body mass index of 34.3 kg/m2, blood Oregon Health & Science to have wide pulse pressure, elevated jugular venous pressure of 177/56 mm Hg, dependent pitting periph- University, Portland, Oregon, pressure, and alternating flushing and blanching of eral oedema, jugular venous pressure of 18 cm H O USA 2 the nail beds in concert with the cardiac cycle, known with a normal waveform, unremarkable S1 and S2 Correspondence to as Quincke’s pulse. Transthoracic echocardiography without extra transient sounds or murmurs, and subun- Dr André Martin Mansoor; demonstrated normal biventricular systolic function gual capillary pulsations (Quincke’s pulse) (video 1). mansooan@ ohsu. edu and valvular function, but noted a dilated inferior vena cava. Right heart catheterisation revealed elevated Accepted 1 July 2021 filling pressures, high cardiac output and low systemic INVESTIGATIONS vascular resistance, consistent with high-output heart Laboratory data were notable for haemoglobin of failure.
    [Show full text]
  • Dynamic Auscultation
    TOP 10 TAKEAWAYS… Jane A. Linderbaum MS, APRN, CNP, AACC Assistant Professor of Medicine Department of cardiovascular disease No Disclosures No off-label discussions 73% of survey respondents identified a need for improved knowledge of CV pathophysiology #10 CARDIAC CIRCULATION, KNOW IT AND LOVE IT The Cardiac Cycle The heart sounds • S1 Mitral (and tricuspid) valve closure Soft if poor EF, loud if good EF • S2 Aortic and pulmonary valve closure Loud if aortic (pulm) pressure • S3 – means “restrictive” filling • S4 – means “abnormal” filling Listening Posts for Auscultation AV – 2nd RICS PV – 2nd LICS MV – 5-6th LICS @ the apex TV – 5-6th LICS parasternal 83% of survey respondents identified themselves as early career in clinic/hospital consult practices # 9 COMMON SYSTOLIC MURMURS YOU WILL DIAGNOSE AND MANAGE MITRAL REGURGITATION MR Treatment • Treat underlying conditions • Consider MV repair when possible at experienced center • Consider MV replacement before ventricle dilates and/or function decreases MITRAL VALVE PROLAPSE Mitral Valve Prolapse Pearls • CHANGE in Murmur (from click-murmur or isolated late sys murmur to holosystolic without audible click) • Skeletal deformities in up to 50% • Upright posture enhances auscultation of the mid-late systolic murmur • May develop severe MR, refer for additional testing as patient may be candidate for mitral valve repair • Murmur may INCREASE with Valsalva • Typically do not require SBE prophylaxis Hypertrophic Cardiomyopathy Hypertrophic Cardiomyopathy • Vigorous LV apical impulse – sustained
    [Show full text]
  • Vascular Responses to Acute Intracranial Hypertension
    J Neurol Neurosurg Psychiatry: first published as 10.1136/jnnp.34.5.587 on 1 October 1971. Downloaded from J. Neurol. Neurosurg. Psychiat., 1971, 34, 587-601 Vascular responses to acute intracranial hypertension S. S. HAYREH1 AND J. EDWARDS From the Department of Experimental Ophthalmology, Institute of Ophthalmology, University of London SUMMARY In 27 rhesus monkeys the cerebrospinal fluid pressure (CSFP) was raised by injections into the cisterna magna to about 40 to 50 mm Hg in steps of 5 mm Hg every five minutes. During the initial phase of the rise of the CSFP to about 15 mm Hg normal animals showed a significant fall in the systolic arterial blood pressure. With a further elevation of the CSFP the BP rose till the CSFP reached 30 to 40 mm Hg. If the CSFP were raised higher than that, a large number of the animals showed a significant fall in the BP. In animals which were shocked before the CSFP was raised there was no drop in the systolic BP during the initial phase. This study indicates that vascular decompensation occurs in the majority of animals when the CSFP goes higher than 30 to 40 mm guest. Protected by copyright. Hg; there is a significant rise in the pulse rate, superior sagittal sinus pressure (SSP), and internal jugular vein pressure (JVP). The JVP was related to the SSP, indicating that the JVP most probably reflected the pressure changes in the intracranial venous sinuses. Four animals suddenly collapsed at the highest CSFP. In the remaining 23 animals, on a sudden lowering of the CSFP to zero from the highest level, 13 monkeys died in less than half an hour and four in about an hour, while six animals stood this elevation of the CSFP well, with a good recovery.
    [Show full text]