Copyright Hbbtv 2017 All Rights Reserved Test Suite V9.2.0 Test Id
Total Page:16
File Type:pdf, Size:1020Kb
Copyright HbbTV 2017 All Rights Reserved Test Suite v9.2.0 Test Id Vers Title Approved Assertion If subtitles are enabled and a broadband delivered FALSE es.tdthibrida_7D7C0040 1 Broadband DVB subtitles in a TS are displayed TS_AVC_SD_25_HEAAC stream containing DVB subtitles (Nordig) is being presented, those subtitles shall be displayed. If subtitles are enabled and a broadband delivered Broadband Teletext subtitles in a TS are FALSE TS_AVC_SD_25_HEAAC stream containing EBU Teletext es.tdthibrida_7D7C0050 1 displayed (Nordig) subtitles is being presented, those subtitles shall be displayed. When broadband delivered subtitles are being displayed FALSE es.tdthibrida_7D7C0060 1 Broadband Subtitles Below Application Graphics in an A/V control object, the subtitles shall be displayed (Nordig) behind the application graphics plane The terminal's user interface shall have a user option FALSE that controls whether auto-start applications are es.tdthibrida_7D7C0070 1 Auto-start applications enabled by default (Nordig) launched automatically, and when in its default manufacturer state this option shall be enabled When the receiver has its default manufacturer-set Application launching with network connection FALSE configuration and the terminal is tuned to a service fr.hdforum_00151000 2 available (Nordig) carrying an AIT signalling one AUTOSTART broadband application, the terminal shall start that application Terminal shall provide an EXIT or TV or comparable FALSE fr.hdforum_00151240 1 EXIT function is provided by receiver button either on a remote control or another control (Nordig) interface. Termination of autostart application using EXIT FALSE Terminal shall terminate a running autostart application fr.hdforum_00151250 1 function (Nordig) when the EXIT function (or equivalent) is used. Terminal shall terminate a running non-autostart Termination of non-autostart broadcast-related FALSE fr.hdforum_00151260 2 broadcast-related application when the EXIT function application using EXIT function (Nordig) (or equivalent) is used. Copyright HbbTV 2017 All Rights Reserved Test Suite v9.2.0 After service selection, with an already running service Test for running PRESENT application after bound application, and the same application signaled as org.hbbtv_00000020 2 TRUE service selection (Service Bound) PRESENT in the AIT of the newly selected service, the terminal shall kill the currently running application. After service selection, with an already running not service bound application, and the same application Test for running AUTOSTART application after org.hbbtv_00000030 1 TRUE signaled with control code AUTOSTART in the AIT of the service selection (Not Service Bound) newly selected service, the terminal shall allow the application to run uninterrupted. After service selection, with an already running not service bound application, and the same application Test for running PRESENT application after org.hbbtv_00000040 2 TRUE signalled with control code PRESENT in the AIT of the service selection (Not Service Bound) newly selected service, the terminal shall allow the application to run uninterrupted. After service selection, with an already running not service bound application, and the same application Test for running DISABLED application after org.hbbtv_00000050 2 TRUE signalled with control code DISABLED in the AIT of the service selection (Not Service Bound) newly selected service, the terminal shall allow the application to run uninterrupted. After service selection, with an already running not service bound application, and the same application Test for KILLED application after service selection org.hbbtv_00000060 2 TRUE signaled with control code KILL in the AIT of the newly (Not Service Bound) selected service, the terminal shall kill the currently running application. After service selection, with an already running not Test for NOT SIGNALLED application after service service bound application, and the same application is org.hbbtv_00000070 2 TRUE selection (Not Service Bound) not signalled in the AIT of the newly selected service, the terminal shall kill the currently running application. Copyright HbbTV 2017 All Rights Reserved Test Suite v9.2.0 While a service is selected and no application is AIT changes while no broadcast related signalled, the terminal shall detect a change in the AIT; org.hbbtv_00000110 3 application is running, AUTOSTART application TRUE which is updated to contain one AUTOSTART application from DSMCC signalled, part 1 carried on a DSMCC carousel. The terminal shall start that application. Terminal is tuned to a service with no application running. The terminal is then tuned to a service with an Service selection with AUTOSTART application AIT which signals one AUTOSTART application carried via org.hbbtv_00000130 2 FALSE from broadband, part 1 (success) HTTP. The terminal has an operational broadband connection. The application is available from this connection. The terminal shall start the application. While a service is selected and no application is signalled, the terminal shall detect a change in the AIT; AIT changes while no broadcast related which is updated to contain two AUTOSTART application is running, multiple AUTOSTART org.hbbtv_00000160 2 TRUE applications. App1 is carried via HTTP; App2 via DSMCC; applications signalled, broadband and broadcast, App1 has a higher priority. The terminal has an part 1 operational broadband connection. The terminal shall start App1. While a service is selected and no application is signalled, the terminal shall detect a change in the AIT; AIT changes while no broadcast related which is updated to contain two AUTOSTART application is running, multiple AUTOSTART org.hbbtv_00000170 2 TRUE applications. App1 is carried via HTTP; App2 via DSMCC; applications signalled, broadband and broadcast, App1 has a higher priority. The terminal has an part 2 operational broadband conntection. App1 is temporarily unavailable. The terminal shall finally start App2. Copyright HbbTV 2017 All Rights Reserved Test Suite v9.2.0 While a service is selected and no application is signalled, the terminal shall detect a change in the AIT; AIT changes while no broadcast related which is updated to contain two AUTOSTART org.hbbtv_00000190 2 application is running, multiple AUTOSTART TRUE applications carried via HTTP, App1 and App2; App1 has applications signalled, broadband, part 1 a higher priority. The terminal has an operational broadband connection. The terminal shall start App1. While a service is selected and no application is signalled, the terminal shall detect a change in the AIT; AIT changes while no broadcast related which is updated to contain two AUTOSTART org.hbbtv_00000200 2 application is running, multiple AUTOSTART TRUE applications carried via HTTP, App1 and App2; App1 has applications, broadband signalled, part 2 a higher priority. The terminal has an operational broadband connection. App1 is temporarily unavailable. The terminal shall finally start App2. While a service is selected and no application is signalled, the terminal shall detect a change in the AIT; AIT changes while no broadcast related which is updated to contain an AUTOSTART application org.hbbtv_00000210 3 application is running, AUTOSTART application TRUE carried on HTTP and DSMCC, with a higher priority for signalled on broadband and broadcast, part 1 HTTP. The terminal has an operational broadband connection. The terminal shall finally start the application from broadband via HTTP. While a service is selected and no application is signalled, the terminal shall detect a change in the AIT; which is updated to contain an AUTOSTART application AIT changes while no broadcast related carried on HTTP and DSMCC, with a higher priority for org.hbbtv_00000220 3 application is running, AUTOSTART application TRUE HTTP. The terminal has an operational broadband signalled on broadband and broadcast, part 2 connection. The app is temporarily not available via the broadband connection. The terminal shall finally start the application from broadcast. Copyright HbbTV 2017 All Rights Reserved Test Suite v9.2.0 While a service is selected and no application is AIT changes while no broadcast related signalled, the terminal shall detect a change in the AIT; application is running, AUTOSTART application which is updated to contain an AUTOSTART application org.hbbtv_00000240 3 TRUE signalled on broadcast (higher priority) and carried on HTTP and DSMCC, with a higher priority for broadband, part 1 DSMCC. The terminal shall start the application from broadcast. While a service is selected and no application is signalled, the terminal shall detect a change in the AIT; AIT changes while no broadcast related which is updated to contain an AUTOSTART application application is running, AUTOSTART application org.hbbtv_00000250 2 TRUE carried on HTTP and DSMCC, with a higher priority for signalled on broadcast (higher prio) and DSMCC. The DSMCC carousel is not present. The broadband, part 2 (failure) terminal shall start the application finally from broadband. While a service is selected and no application is signalled AIT update with no AUTOSTART applications, the terminal detects an AIT which signals one org.hbbtv_00000260 2 TRUE broadband and broadcast, part 3 application with control code PRESENT. The terminal shall not start the application. While service selected, the terminal detects a change in AIT changes while broadcast related application the AIT, a broadcast related application is running and it org.hbbtv_00000270