Release 12.4.1999 IEC 61204: Low voltage power supplies, d.c. output - Part 3: Electromagnetic compatibility (EMC)

CONTENTS Page FOREWORD 3 Clause VERZEICHNIS \t "Überschrift 1;1;Überschrift 2;2;ANNEX-title;1" 1 Scope and object SEITENREF _Toc464803636 \h a) Power supplies intended for free -standing operation (individual apparatus). SEITENREF _Toc464803637 \h b) Component power supplies SEITENREF _Toc464803638 \h 2 Normative references SEITENREF _Toc464803639 \h 3 Terms and definitions SEITENREF _Toc464803640 \h 4 Applicability of tests to different PSU technologies SEITENREF _Toc464803641 \h 5 General requirements and test conditions SEITENREF _Toc464803642 \h 5.1 General requirements SEITENREF _Toc464803643 \h 5.2 Test conditions SEITENREF _Toc464803644 \h 6 Emission requirements SEITENREF _Toc464803645 \h 6.1 Limits in defined environments SEITENREF _Toc464803646 \h 6.2 Low frequency phenomena (f < 9 kHz) (a.c. input only) SEITENREF _Toc464803647 \h 6.3 High frequency conducted phenomena SEITENREF _Toc464803648 \h 6.4 High frequency radiated phenomena SEITENREF _Toc464803649 \h 7 Immunity requirements SEITENREF _Toc464803650 \h 7.1 Performance criteria SEITENREF _Toc464803651 \h 7.2 Basic immunity requirements, high frequency disturbances SEITENREF _Toc464803652 \h 8 Configurations and combinations of power supplies SEITENREF _Toc464803653 \h 8.1 Modular PSUs SEITENREF _Toc464803654 \h 8.2 Power supply systems SEITENREF _Toc464803655 \h 8.3 Power supply installations SEITENREF _Toc464803656 \h 8.4 Distributed power supplies SEITENREF _Toc464803657 \h 8.5 Power supplies in parallel or in series SEITENREF _Toc464803658 \h 9 Power supply families SEITENREF _Toc464803659 \h 10 Statistical aspects SEITENREF _Toc464803660 \h 11 Safety aspects SEITENREF _Toc464803661 \h 12 Test report SEITENREF _Toc464803662 \h Annex A (normative) Guidelines on the classification of PSUs SEITENREF _Toc464803663 \h Annex B (informative) Commutation notches SEITENREF _Toc464803664 \h Annex C (informative) Calculation and simulation of the input current harmonics SEITENREF _Toc464803665 \h Annex D (informative) Special consideration for d.c. inputs SEITENREF _Toc464803666 \h Annex E (informative) Critical frequency for high frequency power measurement SEITENREF _Toc464803667 \h Annex F (normative) Guidelines on power supply families SEITENREF _Toc464803668 \h Annex G (informative) Summary of classification of environments and limits SEITENREF _Toc464803669 \h Annex H (informative) Emission Limits SEITENREF _Toc464803670 \h Annex I (informative) Explanatory remark for applying criterion “B” SEITENREF _Toc464803671 \h 1 Scope and object 4 2 Normative references 5 3 Terms and definitions 6 4 Applicability of tests to different PSU technologies 9 5 General requirements and test conditions 10 5.1 General requirements 10 5.2 Test conditions 10 6 Emission requirements 10 6.1 Limits in defined environments 10 6.2 Low frequency phenomena (f < 9 kHz) (a.c. input only) 11 6.3 High frequency conducted phenomena 12 6.4 High frequency radiated phenomena 12 7 Immunity requirements 15 7.1 Performance criteria 15 7.2 Basic immunity requirements, high frequency disturbances 15 8 Configurations and combinations of power supplies 20 8.1 Modular PSUs20 8.2 Power supply systems 20 8.3 Power supply installations 20 8.4 Distributed power supplies 20 8.5 Power supplies in parallel or in series20 9 Power supply families20 10 Statistical aspects 20 11 Safety aspects 21 12 Test report 21 Annex A (normative) Guidelines on the classification of PSUs 22 Annex B (informative) Commutation notches 24 Annex C (informative) Calculation and simulation of the input current harmonics 25 Annex D (informative) Special consideration for d.c. inputs 26 Annex E (informative) Critical frequency for high frequency power measurement 28 Annex F (normative) Guidelines on power supply families29 Annex G (informative) Summary of classification of environments and limits 30 Annex H (informative) Emission Limits 31 Annex I (informative) Explanatory remark for applying criterion “B” for continuous disturbance phenomena 32 INTERNATIONAL ELECTROTECHNICAL COMMISSION ______LOW VOLTAGE POWER SUPPLIES, DC OUTPUT -

Part 3: Electromagnetic compatibility (EMC)

FOREWORD 1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, the IEC publishes International Standards. Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested National Committees. 3) The documents produced have the form of recommendations for international use and are published in the form of standards, technical reports or guides and they are accepted by the National Committees in that sense. 4) In order to promote international unification, IEC National Committees undertake to apply IEC International Standards transparently to the maximum extent possible in their national and regional standards. Any divergence between the IEC Standard and the corresponding national or regional standard shall be clearly indicated in the latter. 5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with one of its standards. Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 61204-3 has been prepared by subcommittee 22E: Stabilized power supplies , of IEC technical committee 22: Power electronics IEC 61204-3 has the status of a product standard. The text of this standard is based on the following documents: FDIS Report on voting

22E/XX/FDIS 22E/XX/RVD

Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. Annexes A and F form an integral part of this standard; Annexes B, C, D, E, G, H and I are for information only. IEC 61204 consists of the following parts, under the general title: Low voltage power supplies, d.c. output

Part 1: Terms and definitions Part 2: Performance characteristics Part 3: Electromagnetic compatibility (EMC) Part 4: Tests other than EMC Part 5: Measurement of the magnetic component of the reactive near field Part 6: Requirements for low-voltage power supplies of assessed performance Part 7: Safety requirements LOW VOLTAGE POWER SUPPLIES, DC OUTPUT - Part 3: Electromagnetic compatibility (EMC) 1 Scope and object This part of IEC 61204 specifies electromagnetic compatibility (EMC) requirements for power supply units (PSUs) providing d.c. output(s) up to 200 V at a power level of up to 30 kW, operating from a.c. or d.c. source voltages of up to 600 V. The devices are for free-standing operation or for use in other equipment when used with adequate electrical and mechanical protection. For certain specialized industrial PSUs, for example in the chemical and metallurgical industry, other product EMC standards may exist. In this case these standards can be used as an alternative. Since many PSUs are used as components of larger units which are covered by different EMC standards, a classification of power supplies and the applicability of the relevant EMC standards is given in a) and b) below. Further guidelines on classification are given in annexe A. a) Power supplies intended for free -standing operation (individual apparatus). This part of IEC 61204 is applicable to PSUs developed as a unit with a direct function and sold on the market as a stand-alone unit. b) Component power supplies These can be divided into two categories: 1) Component power supplies considered as equivalent to apparatus. This part of IEC 61204 is applicable to this category of component PSUs. These PSUs are considered to be apparatus with respect to their EMC requirements, for example those PSUs intended for use in installations or sold to the general public, cases where no further EMC tests are anticipated. This does not include PSU’s sold as spares for repair which have been tested as part of an overall equipment. 2) Component power supplies intended for a professional assembler / installer This part of IEC 61204 is applicable to this category of power supplies only as an aid to specify relevant EMC requirements in order that various end product standards may be met. These are component power supplies that are intended for incorporation into a final product by a professional assembler. These products may be sold to a professional assembler or placed on the market for specialised distribution and use. In neither case, do they perform in themselves a direct function for the user of an end product. Further EMC tests of the assembly are assumed. NOTE - After incorporation into a final product the emission values can be altered (e.g. because of modified earth connections) The object of this part of IEC 61204 is to define EMC limits and test methods for PSUs. It includes limits for electromagnetic emissions which may cause interference to other electronic equipment (e.g. radio receivers, measuring and computer devices), as well as electromagnetic immunity limits for continuous and transient conducted and radiated disturbances including electrostatic discharges. This part of IEC 61204 defines the minimum electromagnetic compatibility requirements for PSUs. To comply with this part of IEC 61204, no additional EMC tests are required or necessary beyond those stated here. 2 Normative references UNDATED PLEASE The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of IEC 61204. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this part of IEC 61204 are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. IEC 60050(121):1998, International Electrotechnical Vocabulary (IEV) - Part 121: Electromagnetism IEC 60051(131):1978, International Electrotechbnical Vocabulary (IEV) -Chapter 131: Electric and magnetic circuits IEC 60050(151):1978, International Electrotechnical Vocabulary (IEV) - Chapter 151: Electrical and magnetic devices IEC 60050(161):1990, International Electrotechnical Vocabulary (IEV) - Chapter 161: Electromagnetic compatibility IEC 60050(551)--- International Electrotechnical Vocabulary (IEV) - Part 551:Power electronics 1) IEC 60146-1-1:1991, Semiconductor convertors - General requirements and line commutated convertors - Part 1-1: Specifications of basic requirements IEC 60664-1: 1992, Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements, testsIEC 61204:1993, (future IEC 61204-2) Low- voltage power supply devices (PSU) devices, d.c. output - Performance characteristics and safety requirements IEC 61000-3-2:1995, Electromagnetic compatibility (EMC) - Part 3: Limits - Section 2: Limits for harmonic current emissions (equipment input current SONDZEICHEN 163 \f "Symbol" \s 10 16A per phase) Amendment 1 (1997) Amendment 2 (1998) IEC 61000-3-3:1994, Electromagnetic compatibility (EMC) - Part 3: Limits - Section 3: Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current SONDZEICHEN 163 \f "Symbol" \s 10 16A IEC 61000-4-2:1995, Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 2: - Electrostatic discharge immunity test. Basic EMC Publication IEC 61000-4-3:1995, Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 3: Radiated, radio-frequency, electro magnetic field immunity test Amendment 1 (1998) IEC 61000-4-4:1995, Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 4: Electrical fast transient/burst immunity test. Basic EMC Publication IEC 61000-4-5:1995, Electromagnetic compatibility (EMC)- Part 4 : Testing and measurement techniques - Section 5: Surge immunity tests IEC 61000-4-6,:1996, Electromagnetic compatibility (EMC)- Part 4 : Testing and measurement techniques - Section 6:Immunity to conducted disturbances, induced by radio-frequency fields IEC 61000-4-11,:1994, Electromagnetic compatibility (EMC)- Part 4 : Testing and measuring techniques - Section 11: Voltage dips, short interruptions and voltage variations immunity tests CISPR 11: 1990, Limits and methods of measurement of electromagnetic disturbance characteristics of industrial, scientific and medical (ISM) radio-frequency equipment CISPR 14-1: 1993, Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission - Product family standard CISPR 16-1:1993, Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus CISPR 22:1997, Information technology equipment - Radio disturbance characrteristics - Limits and methods of measurement ISO/IEC Guide 25: 1990,General requirements for the competence of calibration and testing laboratories ______1)To be published 3 Terms and definitions For the purpose of this part of IEC 61204, the definitions given in IEC 60050(121), IEC 60050(151), IEC 60050(161), IEC 60050(551) and IEC 60146-1-1, as well as the following definitions apply. 3.1 environment 3.1.1 residential environment refers to all domestic establishments which are directly connected to a low voltage public mains supply. The “protection distance” is 10 m, reflecting apartment size 3.1.2 commercial and light industrial environment refers to commercial and light industrial establishments which may or may not be connected to a low voltage public mains supply. The “protection distance” can be 10 m or 30 m depending on where the use of broadcast radio and television receivers may be expected 3.1.3 industrial environment refers to industrial establishments which are not connected to the low voltage public mains supply. The “protection distance” is 30 m, owing to larger premises 3.2 protection distance distance for an electronic or electrical apparatus beyond which the interference levels shall not impair the use of other electronic or electrical equipment, for example broadcast radio and television receivers 3.3 distributed power system system of localised power converters supplied from a distributed power bus

3.4 port particular interface of a product with the external electromagnetic environment. [IEV 131-02-21 modified] Examples of ports:

EINBETTEN Designer.Drawing.7

3.4.1 enclosure port physical boundary of the PSU product through which and on which electromagnetic fields may radiate or impinge 3.4.2 signal or control line port low energy level input or output port providing diagnostic or control information 3.4.3 d.c. input power port external d.c. energy source connection point 3.4.4 d.c. output power port external connection point for providing output d.c. energy 3.4.5 a.c. input power port external a.c. energy source connection point 3.5 power supply (PSU) an electrical or electronic device which transforms energy from an input source into a single or multiple output energy source 3.5.1 component power supply OEM PSU ; modular PSU ; subunit PSU: assemblies of electrical and/or electronic devices designed to provide or modify energy. They are intended for incorporation into end-products by a professional assembler / installer. They are not intended for free-standing applications 3.5.2 stand alone power supply: intended for use in laboratories, workshops and other areas in free-standing applications. They are end-products, completely enclosed with full protection against electrostatic discharge and contact with hazardous parts which are accessible to the end-user. Typical examples include adjustable or fixed output bench-top units, plug-top units, free- standing and wall-mounted units 3.5.3 bench-top power supply: intended for laboratory or similar use. They are stand alone PSUs, sometimes with monitoring and measuring facilities 3.5.4 open card power supply (frameless PSU): printed circuit board devoid of a metal mounting bracket. It is a component PSU intended for use by a professional assembler 3.5.5 open frame power supply: generally uses a printed circuit board mounted on a metal bracket for attachment to the professional assembler's equipment chassis. This bracket provides heat transfer for the cooling of power semiconductors. Optionally, a cover may be used for safety reasons and/or to reduce radiated interference 3.5.6 plug-in card power supply: intended to be plugged into a subrack. The design may be “open-card“, “open-frame“ or “cased“. A plug-in card PSU is generally intended for use by a professional assembler 3.5.7 enclosed/cased power supply: fully enclosed/cased/housed PSU. The design uses the housing as a heat sink or employs fan(s) for forced air cooling 3.5.8 plug-top (direct plug-in) power supply: power supply built into a mains voltage plug top. 3.5.9 uninterruptible power supply (UPS) UPS: intended to provide a source of energy secure against mains failure. This type of product would normally be free-standing 3.6 end-product finished unit which is designed to stand alone, useable by an end-user and having a direct function for the end-user. It is intended to be placed on the market and/or taken into service as a single unit or as part of a system or installation 3.7 system localised group of interconnected products which is easily relocatable. Typical examples of this would be a computer, including mouse, keyboard, printer and monitor, or a hi-fi system, TV and video recorder 3.8 installation collection of interconnected products which is not easily relocatable. Typical examples of this include an industrial process installation or a power plant control installation 3.9 non-professional person or organisation assumed to have little or no technical knowledge or facilities 3.10 professional assembler/installer technically competent person or organisation capable of correctly assembling/installing components and subassemblies into an end-product, or end-products into a system or installation, and, in so doing, fully complying with the technical and legal requirements of the end-product, system or installation 3.11 full rated load maximum continuous or average power a product is marked to supply 3.12 mains supply 3.12.1 industrial mains supply source of electrical energy provided solely for industrial use 3.12.2 private mains supply localised source of electrical energy (e.g. generator or UPS) which is not directly connected to the public network 3.12.3 public mains supply source of electrical energy provided for general public use in domestic, commercial or light industrial environments 3.13 critical frequency of a PSU The frequency, the wavelength of which is equal to four times the longest side length of the PSU 4 Applicability of tests to different PSU technologies PSUs differ greatly in their technology; it is neither reasonable nor necessary to apply all EMC tests to all PSU technologies. The following table is applicable to free-standing PSUs and component PSUs considered as equivalent to apparatus (see also annex A). In the case of component PSUs intended for a professional installer, this table is provided as a guide. Table 1 - Applicability of tests

Clause or subclause

Group Technology Emission Immunity Remarks

6.2 6.3 6.4 7

I

Modules with pin or screw connections for use on PCBs

NA

R

R

R

These are component power supplies

II

AC/DC Rectifier-filtered or Ferro-resonant PSU

M

M

NA

NA

If only rectifier disturbances

III

AC/DC Linear controlled PSU

M

M NA

M

No switching (note)

IV

DC/DC Converters, battery or rectifier powered

NA

R

M

M

No primary rectifier, no direct connection to a.c.supply

V

AC/DC PSUs not covered by I, II, III or IV

M

M

M

M

NOTE - When products or system are within the scope of CISPR 14-1, the incorporated group III PSUs may be tested according to CISPR 14-1.

M = Mandatory R = Recommended NA = No measurement

5 General requirements and test conditions 5.1 General requirements The manufacturer of the PSU has a responsibility to provide information relating to the EMC performance, application, intended environment and installation guidelines for the product. 5.2 Test conditions The tests shall be performed using the manufacturer’s recommended wiring and installation instructions. There will be no connections other than those specified by the manufacturer. The configuration, orientation and electrical test conditions of the PSU shall be representative of the worst case in-service conditions, if known. Otherwise, all measurements shall be performed at rated nominal input voltage, full rated load and ambient temperature between 15 °C and 35 °C. The PSU shall be at its normal operating temperature. The load is presumed not to generate any electromagnetic interference. Load resistors may be cooled by a fan or cooling fluid. All tests specified in this standard are type tests only. The equipment shall meet the requirements when measured by the test methods specified. No additional EMC tests are required or necessary beyond those stated in this standard. Precautions shall be taken against the equipment under test becoming dangerous or unsafe as a result of the immunity tests specified in this standard. 6 Emission requirements If the cable arrangements of the application are known, then those shall be used. If it is not known, the arrangements shall be chosen in accordance with 6.3 and 6.4. The measuring conditions shall be stated within the documentation. 6.1 Limits in defined environments The environments in which a PSU may be installed are classified as follows: Residential environment Examples of typical locations are: - residential properties, for example houses, apartments, etc.; Commercial and light industrial environment Examples of typical locations are: - retail outlets, for example shops, supermarkets, etc.; - business premises, for example offices, banks, etc.; - establishments of public entertainment, for example cinemas, public bars, dance halls, etc.; - outdoor locations, for example petrol stations, car parks, amusement and sports centres, etc.; - light-industrial locations, for example workshops, laboratories, service centres, etc. Industrial environment The limits for the above-mentioned environments are given below and a summary is given in annex G.

6.1.1 Class B limits PSUs which meet class B limits are defined as class B equipment. They are intended to be installed in a residential environment. Class B limits are also required for PSUs installed in a commercial or light industrial environment when the equipment is directly connected to a public mains supply interconnected with a residential environment. 6.1.2 Class A limits PSUs which meet class A limits are defined as class A equipment. They are intended to be installed in a commercial, light industrial or industrial environment where the equipment is not directly connected to a public mains supply interconnected with a residential environment. Class A equipment shall carry the following remark in its documentation: Warning: This is a class A product. In a residential, commercial or light industrial environment it may cause radio interference. This product is not intended to be installed in a residential environment; in a commercial and light industrial environment with connection to the public mains supply the user may be required to take adequate measures to reduce interference.

The user, advised by the supplier, is responsible for the electromagnetic compatibility of the installed product in his environment.

6.1.3 Special applications This concerns the industrial environment only where equipment with high input current (>25A) is connected to an industrial mains supply, or a private mains supply, and where the protection distance is > 100m. Limits are under consideration. In these applications, clear warning of the restricted use of the equipment shall be given in the documentation supplied with it. Examples: - internal radio interference tolerated by the user and external interference within acceptable limits. (e.g. mains supply independent of public mains supply); - safety requirements in conflict with EMC requirements in high power installations. 6.2 Low frequency phenomena (f < 9 kHz;) (a.c. input only) 6.2.1 Commutation notches Within this subclause only PSUs with commutation of the primary current are covered. PSUs of high power designed as line commutated converters may cause notches if connected to a high impedance source. Measurements or calculations are not mandatory. Information and recommenda tions are given in annex B. 6.2.2 Current harmonics and interharmonics The limits for PSUs connected to a public mains supply up to and including a rated input current of 16 A are given in IEC 61000-3-2. This requirement is applicable to apparatus and components considered as apparatus covered within the scope of IEC 61000-3-2, but it is not mandatory for PSUs used in countries were there are no regulations requiring product harmonic limits. Harmonic measurements, especially on PSUs, are sensitive to the voltage source. In many cases, the public mains supply may not be a suitable source for this purpose. Therefore, one of the following methods shall be used. a) Using a public mains supply in accordance with IEC 61000-3-2. - The limits for the harmonics of the voltage source shall be met with the PSU operating at full rated load. b) Using an artificial supply in accordance with IEC 61000-3-2. c) Calculation or simulation if it takes into account: - the voltage source as an ideal sine wave; - the worst case internal impedance of the PSU in the frequency range from the line frequency up to the 40th harmonic. For recommendations: see annex C. Interharmonics may occur under specific load conditions which cannot be taken into account in this standard; this system aspect is within the responsibility of the user, installer or assembler. 6.2.3 Voltage fluctuations and flicker The limits for PSUs connected to a public mains supply up to and including a rated input current of 16 A are given in IEC 61000-3-3. This requirement is applicable to apparatus and components considered as apparatus covered within the scope of IEC 61000-3-3, but it is not mandatory for PSUs used in countries were there are no regulations requiring voltage fluctuations and flicker limits. For PSUs, only measurements or calculations for dmax (maximum relative voltage change) are necessary. NOTE - It is recommended to measure the amplitude and the duration of the inrush current and to calculate the r.m.s. value in the first period after switching-on. Most PSUs have inrush current less than 10 ms which means that high inrush currents are still below the dmax limit. Fluctuations of the PSU input current may be caused by a time varying load on the PSU. This system aspect is within the responsibility of the user, installer or assembler. 6.3 High frequency conducted phenomena 6.3.1 High frequency line conducted phenomena The tests of conducted emission shall be performed in accordance with CISPR 22, or CISPR 11 in the case of industrial applications. However CISPR 22 is not precluded from use for Industrial applications. Limits are listed in Annex H, Table H.1 For d.c. input see Annex D. 6.3.2 High frequency conducted phenomena for d.c. output power ports This standard does not define limits for load terminal disturbance voltage for high frequency conducted phenomena on d.c. output ports. In some cases, manufacturer and user may need to agree limits. NOTE- The manufacturer is recommended to give application advice in the documentation as how to avoid feedback from the load cables to the mains. 6.4 High frequency radiated phenomena The radiation test can be made with an antenna according to CISPR 22, or with the absorbing clamp method according to CISPR 16-1 with the restrictions stated in 6.4.3. The manufacturer must justify the choice of the interference power measurement in the documentation and test report, in case of dispute the test method of the manufacturer applies. Limits are listed in Annex H, table H.2. 6.4.1 Tests with an antenna The tests of radiation disturbance shall be performed in accordance with CISPR 22. Load cables of unknown length shall be arranged horizontally, equally separated from each other and shall be 1 m in length. The mains cable is arranged 1 m horizontally and then 0,8 m vertically to the ground where it is connected to the power source. Cables are unshielded, unless the PSU is supplied with a shielded cable. Any other arrangement shall be justified and explained within the documentation. The distance between the antenna and the PSU shall be 10 m if the limits of table H.21 in Annex H are applied. At a measuring distance of 30 m the limits are reduced by 10 dB. At a measuring distance of 3 m the limits are increased by 10 dB. 6.4.2 Test with clamp method The measuring receiver shall have a quasi-peak detector and shall be in accordance with the requirements of CISPR 16-1. The absorbing clamp shall be designed and calibrated in accordance with CISPR 16-1. NOTE- The clamps generally refer to a 10 m radiated field measurement. Measurement set-up and procedure: see figure 1. The PSU and the cable to be tested shall be placed on a non-metallic support of 0,8 m height and at least 0,8 m from all other metallic objects. The cable under test is stretched in a straight line over a length of at least 5 m on a non- metallic support allowing the absorbing clamp to be moved along the cable under test. The clamp shall be placed around the cable in the correct orientation (current sensor on the side of the PSU). All other cables are either disconnected (if the correct operation of the equipment can be maintained without the cables), or equipped with absorbing ferrite tubes(clamps) close to the PSU. Each cable of the PSU shall be tested in turn. Cables which are longer than 5 m are tested as described above with 5 m of cable in the test set-up. The layout of the excess cable is not critical. Cables which,in normal application, are restricted in length to less than 5 m are tested as follows: - cables with a restricted length of SONDZEICHEN 163 \f "Symbol" \s 10 0,25 m are not measured at all; - < s are lengthened to s; - > s are measured over the total length. s = two times the length of the clamp. The clamp shall be displaced along the cable under test, starting closest to the PSU up to a maximum of 5 m. The maximum reading is converted into disturbance power, using the clamp calibration factor. The displacement needed is from zero to a half-wavelength of the measured frequency. All maxima shall be below the limits given in table H.2 of Annex H

Figure 1 - Test set-up for the measurement of disturbance power 6.4.3 Restrictions for the application of interference power measurement The measurement of interference power may be used instead of radiated field strength with the restriction that the longest side length of the box does not exceed SONDZEICHEN 108 \f "Symbol" \s 10 /4 of the highest measured frequency. (In accordance with CISPR 16-1.) Most PSUs do not emit interference power above this critical frequency. (Calculation of the critical frequency of the PSU: see annex E.) Some PSUs can emit interference power above the critical frequency. This is especially so when logic circuitry with a clock frequency above 1 MHz is used. The application of the high frequency power test method is therefore restricted to PSUs withoutshielded cables and: - with a longest side length less than SONDZEICHEN 108 \f "Symbol" \s 10 /4 of the highest frequency measured; - with a clock frequency less than 1 MHz; - with less than 5 outputs; which do not prevent the use of the clamp because of a too large diameter of the leads.

7 Immunity requirements 7.1 Performance criteria The performance criteria shall be used to check the acceptability of a PSU against external disturbances. From the EMC point of view any process including a PSU shall be operating as intended. If as a result of the application of the tests defined in this standard, the PSU becomes dangerous or unsafe, then the PSU shall be deemed to have failed the test.

Table 2 - Criteria to prove the performance of a PSU against EM disturbances

Performance criteria A

B

C

Basic specifications No loss of function or performance during the test

Temporary loss of function or performance during the test. Self-recoverable

Loss of function or performance. Not self-recoverable. Not damaged

Remarks

Operating as intended within specified tolerance

Degradation of performance shall be specified by the manufacturer. PSU shall continue to operate as intended after the test

Any resettable condition allowed including shut-down.

Performance criteria in the following tables have been considered as minimum requirements. These limits have been set to avoid imposing levels which may be unnecessary for the application. For some applications, it may be necessary for the customer and supplier to agree to higher levels. (See also annex D for DC/DC converters.)

7.2 Basic immunity requirements, high frequency disturbances The test set-up is given in a column in tables 3 - 10, referring to basic standards. Note: Tr/Th refers to rise time and impulse duration (50 % value), as described in IEC 61000-4-4. For surge tests, apparatus with a d.c.power input port, intended for use with an a.c./d.c. power adapter, shall be tested on the a.c. power input of the a.c./d.c. a.c./d,c, power adapter specified by the manufacturer. 7.2.1 Low severity levels These levels are applied to PSUs which are intended to be used in residential, commercial or light industrial environments.

Table 3 - Immunity - Enclosure port

Environmental phenomenon Test item Test specification Unit Test set-up Remarks

Performance criteria

3-1 Electrostatic discharge Contact discharge Air discharge ± 4

± 8 kV kV IEC 61000-4-2 1)

B

3-2 Radio-frequency electromagnetic field Amplitude mmodulated Frequency Fieldstrength AM 1kHz

80 - 1000 3 80 MHz V/m % IEC 61000-4-3 2) 3)

B

3-3 Radio-frequency electromagnetic field. Keyed carrier Frequency Fieldstrength Duty cycle Repetition ffrequency 900 ± 5 3 50 200 MHz V/m % Hz IEC 61000-4-3 4)

B

1) In the case of an open frame PSU, the ESD test is impractical and need not be carried out. 2) This level does not represent the field emitted by a transceiver in close proximity to the PSU. 3) The test level specified is the r.m.s. value of the unmodulated carrier. 4) This test is applied only in European countries. The test shall be carried out at one frequency within the indicated range.

Table 4 - Immunity - Ports for signal lines and control lines Environmental phenomenon Test item Test specification Unit Test set-up Remarks

Performance criteria

4-1 Fast transients

Peak line-to- line voltage Tr/Th Repetition frequency

SONDZEICHEN 177 \f "Symbol" \s 8 0,5 5/50

5 kV ns kHz

IEC 61000-4-4 1) Capacitive clamp used

B

4-2 Radio-frequency continuous conducted Frequency Amplitude AM (1kHz)

0,15-80 3 80 MHz V % IEC 61000-4-6

2)

B

1) Applicable only to ports interfacing with cables, the total length of which, according to the manufacturers functional specification may exceed 3 m. 2) The test level specified is the r.m.s. value of the unmodulated carrier.

Table 5 - Immunity - DCD.C. input and output power ports

The following requirements are not applicable to input ports intended for connection to a battery, or to a rechargeable battery which must be disconnected from the equipment for recharging. The stated limits may not be sufficient for some special applications, see annex D.Following requirements are not applicable to input ports intended for connection to a battery, or to a rechargeable battery which must be disconnected from the equipment for recharging. The stated limits may not be sufficient for some special applications, see annex D.

Environmental phenomenon Test item Test specification Unit Test set-up Remarks

Performance criteria

5-1 Fast transients

Peak line-ground voltage Tr/Th Repetition frequency

SONDZEICHEN 177 \f "Symbol" \s 8 0,5 5/50

55 kV ns kHz IEC 61000-4-4 1) B

5-2 Surges Tr/Th peak line-ground voltage peak line-to-line voltage 1,2/50 (8/20)

SONDZEICHEN 177 \f "Symbol" \s 8 SONDZEICHEN 177 \f "Symbol" \s 8 0,5 µs kV kV IEC 61000-4-5 2) B

5-3 Radio-frequency continuous conducted Frequency Amplitude AM (1kHz) 0,15-80 3 80 MHz V % IEC 61000--4-6 1), 3), 4) B

1) The test is applicable to d.c. input power ports intended to be connected permanently to cables longer than 10 m. 2) Applicable only to input ports. 3) Applicable only to ports interfacing with cables the total length of which may exceed 3m according to the manufacturers functional specification. 4) The test level specified is the r.m.s. value of the unmodulated carrier.

Table 6 - Immunity - ACA.C. input power ports

Environmental phenomenon Test item Test specification Unit Test set-up Remarks

Performance criteria

6-1 Fast transients

Peak line-ground voltage Tr/Th Repetition frequency

SONDZEICHEN 177 \f "Symbol" \s 8 1

5/50 5 kV ns kHz IEC 61000-4-4

B

6-2 Surges Tr/Th peak line-ground voltage peak line-to-line voltage 1,2/50 (8/20)

SONDZEICHEN 177 \f "Symbol" \s 8 SONDZEICHEN 177 \f "Symbol" \s 8 1 µs kV kV IEC 61000-4-5 1) B

6-3 Voltage dips Reduction Duration

Reduction Duration 30 10

60 100 % ms

% ms IEC 61000-4-11

B C

6-4 Voltage interruptions Reduction Duration > 95 5000 % ms IEC61000-4-11

C

6-5 Radio-frequency continuous conductedd

Frequency Voltage AM(1kHz) 0,15-80 3 80 MHz V % IEC 61000-4-6 2) B

1) For products designed for installation class I according to IEC 60664-1 , the surge limits may be reduced by 50 % 2) The test level specified is the r.m.s. value of the unmodulated carrier.

7.2.2 High severity levels These levels are applied to PSUs which are intended to be used in an industrial environment. In case of disturbances beyond the following levels, a solution has to be agreed between the customer and the supplier. Table 7 - Immunity - Enclosure port

Environmental phenomenon Test item Test specification Unit Test set-up Remarks

Performance criteria

7-1 Electrostatic discharge Contact discharge Air discharge ± 4

± 8 kV kV IEC 61000-4-2 1) B

7-2 Radio-frequency electromagnetic field Amplitude modulated Frequency Field strength AM 1kHz 80 - 1000 10 80 MHz V/m % IEC 61000-4-3 2) 3) B

7-3 Radio-frequency electromagnetic field Keyed carrier Frequency Field strength Duty cycle Repetition frequency 900 ± 5 10 50

200 MHz V/m %

Hz IEC 61000-4-3 4) B

1) In the case of an open frame PSU, the ESD test is impractical and need not be carried out. 2) This level does not represent the field emitted by a transceiver in close proximity to the PSU. 3) The test level specified is the r.m.s. value of the unmodulated carrier. 4) This test is applied only in European countries. The test shall be carried out at one frequency within the indicated range.

Table 8 - Immunity - Ports for signal lines and control lines

Environmental phenomenon Test item Test specification Unit Test set-up Remarks Performance criteria

8-1 Fast transients

Peak line-to-line voltage Tr/Th Repetition frequency

SONDZEICHEN 177 \f "Symbol" \s 8 2

5/50 5 kV ns kHz IEC 61000-4-4 1) Capacitive clamp used B

8-2 Radio-frequency common mode Amplitude mmodulated Frequency Amplitude Modulation

0,15-80 10 80 MHz V % IEC 61000-4-6

1) 2) B

1) Applicable only to ports interfacing with cables the total length of which may exceed 3 m according to the manufacturers functional specification. 2) The test level specified is the r.m.s. value of the unmodulated carrier.

Table 9 - Immunity - DC input and output power ports Following requirements are not applicable to input ports intended for connection to a battery, or to a rechargeable battery which must be disconnected from the equipment for recharging. The stated limits may not be sufficient for some special applications, see annex D.Table 9 - Immunity - D.C. input and output power ports The following requirements are not applicable to input ports intended for connection to a battery, or to a rechargeable battery which must be disconnected from the equipment for recharging. The stated limits may not be sufficient for some special applications, see annex D.

Environmental Phenomenon Test item Test sSpecification Unit Test set-up Remarks

Performance criteria

9-1 Fast transients

Peak line-ground voltage Tr/Th Repetition frequency

SONDZEICHEN 177 \f "Symbol" \s 8 2

5/50 5 kV ns kHz IEC 61000-4-4 1) B

9-2 Surges Tr/Th Peak line-ground voltage Peak line-to-line voltage 1,2/50 (8/20)

SONDZEICHEN 177 \f "Symbol" \s 8 SONDZEICHEN 177 \f "Symbol" \s 8 0,5 µs kV kV IEC 61000-4-5 2) B

9-3 Radio-frequency Continuous Conducted Frequency Amplitude AM (1kHz) 0,15-80 10 80 MHz V % IEC 61000-4-6 1), 3), 4) B

1) The test is applicable to d.c. input power ports intended to be connected permanently to cables longer than 10 m. 2) Applicable only to input ports. 3) Applicable only to ports interfacing with cables the total length of which may exceed 3m according to the manufacturers functional specification. 4) The test level specified is the r.m.s. value of the unmodulated carrier.

Table 10 - Immunity - ACA.C. input power ports

Environmental phenomenon Test item Test specification Unit Test set-up Remarks

Performance criteria

10-1 Fast transients

Peak line-ground voltage Tr/Th Repetition frequency

SONDZEICHEN 177 \f "Symbol" \s 8 2 5/50 5 kV ns kHz IEC 61000-4-4

B

10-2 Surges Tr/Th Peak line-ground voltage Peak line-to-line voltage 1,2/50 (8/20)

SONDZEICHEN 177 \f "Symbol" \s 8 SONDZEICHEN 177 \f "Symbol" \s 8 1 µs kV kV IEC 61000-4-5 1) B

10-3 Voltage dips Reduction Duration

Reduction Duration 30 10

60 100 % ms

% ms IEC 61000-4-11

B

C

10-4 Voltage interruptions Reduction Duration > 95 5000 % ms IEC 61000-4-11

C

10-5 Radio-frequency continuous conducted

Frequency Voltage AM(1kHz) 0,15-80 10 80 MHz V % IEC 61000-4-6 2) B

1) In some industrial environments higher limits may be required. 2) The test level specified is the r.m.s. value of the unmodulated carrier.

8 Configurations and combinations of power supplies 8.1 Modular PSUs A PSU with a single primary circuit or module and separate output modules forming a single unit, synchronised or not, shall meet the requirements defined in this standard as a single component or apparatus type of PSU. 8.2 Power supply systems An easily relocatable system containing several PSUs in parallel, in series or combination with a single input connection shall comply to this standard as a single component or apparatus type of PSU. It is the responsibility of the system supplier to ensure EMC compliance with this standard or with a specific EMC standard of the end product. 8.3 Power supply installations When a number of PSUs are used in an installation and are supplied by a distributed a.c. or d.c. network then this is a power installation. This type of arrangement is not easily relocatable. Each individual PSU shall comply with this standard and this is the responsibility of the PSU manufacturer who shall also provide information on the correct installation of his product. The EMC considerations of the final installation are the responsibility of the professional installer. 8.4 Distributed power supplies This is a power installation where the input a.c. or d.c. supply is distributed to individual power conversion units or modules which are installed locally to the circuitry to be supplied. This standard applies to the individual products as appropriate. The EMC performance of the overall system or installation is the responsibility of the professional installer. 8.5 Power supplies in parallel or in series Where PSUs are sold to be connected in parallel or in series, their documentation shall include information relating to the expected EMC performance for such arrangements.

9 Power supply families A power supply family consists of PSUs with similarities between members. It is neither economic nor sensible to measure the EMC performance of all members of the family. It is the responsibility of the manufacturer to decide which members of the family should be tested as being representative of the entire family. This decision shall be justified in the test report. See also annex F. 10 Statistical aspects The limits in this standard are set taking measurement uncertainties into account. As a consequence the measured value of one product sample shall be compared directly with the limits. - One product sample means one piece. - In case of dispute, the 80 / 80 % rule stated in CISPR 16-1 shall apply. NOTE- Uncertainty of measurement is a parameter, associated with the result of measurement, that characterises the dispersion of the values that could reasonably be attributed to the measure and in accordance with ISO/IEC Guide 25 to the expression of uncertainty in measurement. Measurement uncertainty arises from random effects and from imperfect correction for systematic effects. 11 Safety aspects EMC mitigation measures shall not violate the required safety provisions; for example mains filters influence the touch current and EMC screens can influence clearance or creepage distances. Equipment shall not become dangerous or unsafe as a result of immunity tests defined in this standard. Therefore, type tests for EMC compliance shall be concluded before safety type tests are carried out or in parallel as long as any changes to the equipment due to EMC testing are retested for compliance with product safety requirements. 12 Test report The test results shall be documented in a test report. The report shall give sufficient product identification and test data. It shall clearly, unambiguously and objectively present all relevant information of the tests such as load conditions, cable length, earthing, etc. A functional description of the test set-up, including test equipment, cable layout and the modes of operation during the test shall be given. A detailed definition and a justification of the chosen acceptance criteria shall be provided by the manufacturer and noted in the test report. The report shall give the actual measured values for each test and relate them to the limit values. Annex A (normative) Guidelines on the classification of PSUs

Because many PSUs are used as part of larger units, referring to different EMC standards, a classification is necessary. This annex provides some examples of product classification, but it is the manufacturer's responsibility to determine the classification. A.1 Power supplies intended for free-standing operation The manufacturer is responsible for all relevant EMC tests to be applied to these PSUs. This category includes, for example: - bench top PSUs for laboratory or similar use; - stand alone PSUs for industrial applications; - plug top PSUs with switched mode control; - industrial battery chargers; - plug top PSUs with no internal high frequency generator; - domestic battery chargers; - communication power system. A.2 Component power supplies a) Considered as equivalent to apparatus These power supplies are intended for sale to an end-user or installer. The manufacturer is responsible for all relevant EMC tests to be applied to these PSUs. This category includes, for example: - PSUs with integral mains and/or IT equipment connectors that are sold to the general public for upgrading PCs, for use with printers, etc.; - PSUs intended to be used (with the addition of appropriate casing wiring, etc.) in installations where the EMC performance will not be measured by the installer; - a 24 V output PSU, within a safe box, intended for “installation”; - PSUs for amateur electronics. This category does not include PSUs sold to the general public or for use in installations, where these are spares for repair and have been tested as part of an overall equipment. b) Intended for a professional assembler This category includes, for example: - most open card, cased and PCB mounted PSUs (both plug in and wired); - rack subassembly PSUs which are intended for use only by professional assemblers; - PSUs sold as spares for repair where this PSU has been tested as part of the final product by a professional assembler.

Table A.1 gives an overview of the application of EMC standards to PSUs classified in accordance with clauses A.1 and A.2. Table A.1 - Classification of power supplies and the relevant EMC standards

Power supply

EMC standard

A.1 Apparatus

IEC 61204-3

A.2 Components

a) Considered to be equivalent to apparatus

b) Intended for a professional assembler

IEC 61204-3

IEC 61204-3 used as an aid.

IEC 61204-3 may be replaced by an end-product EMC standard, as agreed between the PSU manufacturer and assembler or as required by the intended specific application.

Annex B (informative) Commutation notches

The problem of commutation notches exists only for a very small percentage of PSUs, therefore no measurements or calculations are mandatory. In relevant cases, the manufacturer and the user have to agree the limit of the notches; this annex gives some common explanations of the problem. The effect of commutation notches is well-known from line commutated converters of high power, especially if connected to voltage sources of high impedance. It is a system effect because it is dependent both on the internal line impedance and the converter characteristics. High power PSUs within the scope of this standard may be designed as line commutated converters. The notch problem is much less severe because of the relatively low power compared with converters for drives or high power UPS. Notches are defined in IEC 60146-1-1. They can be reduced by commutation impedances in series with the converter source connectors. The impedance needed depends on the internal impedance of the power source, the input impedance of the PSU and the limit of the notches at the source connectors. Generally, line commutated PSUs are connected to an industrial mains supply where commutation notches of up to 40 % are usual. The limits of notches at a public mains supply must comply with the limits of the local supply authority. The calculation of the commutation impedances is well-known and needs no further information. Annex C (informative) Calculation and simulation of the input current harmonics

Generally, public mains supplies do not meet the requirements for testing the equipment against IEC 61000-3-2, annex A. In those cases, artificial voltage sources are necessary for the measurement of input current harmonics, the nominal power of which may need to be considerably higher than the rated power of the PSU because of the high peaks of input current and the requirement that the limits for harmonic currents shall be met with the PSU operating at full rated load. Therefore, the calculation or simulation method is commonly used for products of high power. If the internal input impedances of the PSU up to the 40th harmonic are known, simulation can be a reasonable solution to evaluate harmonics, even for low power PSUs. If impedances are not exactly known, the worst case value is to be used. To avoid simulation errors, it is recommended that a batch test is performed for a typical case of a PSU family and that the results of the measurement are compared with the simulation. In case of doubt, measurement is preferred. Annex D (informative) Special consideration for d.c. inputs

D.1 General DC/DC converters according to group IV of table 1 of this standard are considered to be supplied directly from a PSU or from a battery. For some DC/DC converter applications, the definitions used in this standard for low severity and high severity, as well as for emission classes do not reflect the actual environments in which a DC/DC converter can be located. D.2 Emission For conducted emissions no tests are mandatory on d.c. inputs. However, it is recommended that class A limits are met on all DC/DC converters which are not components as defined in 1.b.2 For limits, see Annex H, Table H.1 For DC/DC converters with an input voltage SONDZEICHEN 163 \f "Symbol" \s 10 60V, which are used in distributed power systems and installations in special applications (e.g. Telecom stations), the use of class B limits may be necessary. D.3 Immunity Higher immunity levels than specified in this standard are recommended for DC/DC. converters and which are: - supplied by a generator (e.g. cars, ships), in a system with d.c. motor drives (e.g. fork-lifts, electric cars) or from high voltage converters (e.g. trains, streetcars); - in industrial applications where the nominal d.c. input voltages are higher than 60 V; - in power distribution systems in industrial applications (e.g. power plants, process industry). The minimum immunity level for this class of DC/DC converters is defined in 7.2., tables 3, 4, 5, 7, 8 and 9. For a higher degree of immunity on the d.c. input, the levels of tables D.1, D.2, and D.3 are recommended for the following input categories: a) nominal d.c. input voltage SONDZEICHEN 163 \f "Symbol" \s 10 100V if fed from a generator, d.c. drives system or high voltage converter; b) nominal d.c. input voltage > 100V Table D.1 - Immunity - DCD.C. input power ports - Input category a)

Environmental phenomenon Test item Test sSpecification Unit Test sSet-up Remarks

Performance criteria D.1-1 Fast transients

Peak line-ground voltage Tr/Th Repetition frequency

SONDZEICHEN 177 \f "Symbol" \s 8 2

5/50 5 kV ns kHz IEC 61000-4-4

B

D.1-2 Surges Tr/Th Peak line-ground vvoltage Peak line-to-line voltage 1,2/50 (8/20)

SONDZEICHEN 177 \f "Symbol" \s 8 SONDZEICHEN 177 \f "Symbol" \s 8 0,5 µs kV kV IEC 61000-4-5

B

D.1-3 Radio-frequency continuous conducted Frequency Voltage AM(1kHz) 0,15-80 10 80 MHz V % IEC 61000-4-6 1), 2) B

1) The test is applicable to d.c. input ports intended to be connected permanently to cables longer than 10 m. 2) The test level specified is the r.m.s. value of the unmodulated carrier.

Table D.2 - Immunity - DCD.C. input power ports - Input category b) Tests applicable to d.c. power ports intended to be connected permanently to cables longer than 10 m.

Environmental phenomenon Test item Test specification Unit Test sSet-up Remarks

Performance criteria

D.2-1 Fast transients

Peak line-ground voltage Tr/Th Repetition frequency

SONDZEICHEN 177 \f "Symbol" \s 8 4 5/50 5 kV ns kHz IEC 61000-4-4

B

D.2-2 Surges Tr/Th Peak line-ground voltage Peak line-to-line voltage 1,2/50 (8/20)

SONDZEICHEN 177 \f "Symbol" \s 8 SONDZEICHEN 177 \f "Symbol" \s 8 1 µs kV kV IEC 61000-4-5 1) B

D.2-3 Radio-frequency continuous conducted

Frequency Voltage AM(1kHz) 0,15-80 10 80 MHz V % IEC 61000-4-6 2) B

1) In some industrial environments higher limits may be required. 2) The test level specified is the r.m.s. value of the unmodulated carrier.

Table D.3 - Immunity - Enclosure port - Input categories a and b

Environmental phenomenon Test item Test specification Unit Test sSet-up Remarks

Performance criteria

D.3-1 Radio-frequency electromagnetic field Amplitude modulated Frequency Fieldstrength AM 1kHz 80-1000 10 80 MHz V/m % IEC 61000-4-3 1) 2) B

D.3-2 Radio-frequency electromagnetic field. Keyed carrier Frequency Fieldstrength Duty cycle Repetition frequency 900 ± 5 10 50

200 MHz V/m %

Hz IEC 61000-4-3 3) B

1) This level does not represent the field emitted by a transceiver in close proximity to the PSU. 2) The test level specified is the r.m.s. value of the unmodulated carrier. 3) This test is applied only in European countries. The test shall be carried out at one frequency within the indicated range.

Annex E (informative) Critical frequency for high frequency power measurement

Calculation of the critical frequency of a PSU The maximum test frequency for the absorbing clamp measurement, in accordance with CISPR 16-1, is defined, in this part of IEC 61204, as the critical measuring frequency of the PSU. CISPR 16-1 requires that the longest side length of an EUT shall be:

EINBETTEN Equation.2 EINBETTEN Equation.2 is the longest side length of the PSU in metres; SONDZEICHEN 108 \f "Symbol" \s 11 is the wavelength of the measuring frequency in metres; c is the speed of light ( SONDZEICHEN 64 \f "Symbol" \s 10 3 x 10 8 m/s).

Annex F (normative) Guidelines on power supply families General This annex provides some assistance in judging the test philosophy of power supply families, but it is the manufacturer who will ultimately decide how many different representative products need to be tested. A power supply family consists of a set of PSUs with similarities between its members. It may be possible to select one family member that is representative of all the other members in respect of EMC, but usually it would be necessary to test several PSUs. The basis of the testing philosophy, including decisions, conclusions and a description of the products covered by the test plan, should be detailed in the test report or file. Choice of family members to be tested is clearly dependent on the similarities between family members. Not all input/output combinations need to be tested, but it would be advisable to test all different input sections and all different output sections at least once. Items that may influence emission are: - the type of enclosure - ventilation slots, - connectors, - input/output filter design, - wiring lengths - layout and type, - ground management, - switching components, - control of the switching components, - magnetic components, - different sources of the same component, - the printed circuit board design.

Items that may influence the immunity performance are: - the type of enclosure, - ventilation slots, - connectors, - input/output filter design, - magnetic components, - wiring lengths, - layout and type, - ground management, - control loops1), - printed circuit board design, - decoupling.

The tests specified in IEC 61000-4-3, IEC 61000-4-4 and IEC 61000-4-6 may affect the output regulation. Annex G (informative) Summary of classification of environments and limits Table G.1

Environment

Protection distance m

Mains supply

Class emission limits

Severity level immunity

Residential

10

Public

B

Low

Commercial + light industrial

10

Public

B (A) 1)

Low

Commercial + light industrial 30

Public

A 1)

Low

Commercial + light industrial, Industrial

30

Industrial

A

High

Special

100

Industrial or private t.b.d.to be decided

Low or high 2)

1) In a commercial or light industrial location with connection to the public mains supply, the user of a class A PSU may be required to take measures to reduce interference. See 6.1. 2) High severity limits are required when one or more of the conditions characterizing industrial locations exists.

Annex H (informative) Emission Limits

These limits have been copied for information only without alteration from CISPR 11 and CISPR 22.

Table H.1 - Limits of mains terminal disturbance voltage (a.c. input port)

Class B limits Class A limits

Frequency MHz

Quasi-peak dB( SONDZEICHEN 109 \f "Symbol" \s 8 V)

Average dB( SONDZEICHEN 109 \f "Symbol" \s 8 V)

Quasi-peak dB( SONDZEICHEN 109 \f "Symbol" \s 8 V)

Average dB( SONDZEICHEN 109 \f "Symbol" \s 8 V) 0,15 to 0,5 0,5 to 5 5 to 30

66 to 56 1) 56 60

56 to 46 1) 46 50

79 73 73

66 60 60

1) limit decreasing linearly with logarithm of frequency.

NOTE- For d.c. input see annex D.

Table H.2 - Limits for electromagnetic radiation/interference power disturbance (all field strength limits refer to quasi-peak measurements)

Class B limits

Class A limits

Frequency band MHz Quasi-peak dB( SONDZEICHEN 109 \f "Symbol" \s 8 V/m) 1) Distance m Quasi-peak dB( SONDZEICHEN 109 \f "Symbol" \s 8 V/m) 1) Distance m

30 to 230

230 to 1000

30

37

10

40

47

10

1) dB(pW) if interference power is measured instead of field strength.

Alternatives to the 10 m field strength measurement: - 30 m = 10 m limits - 10 dB - 3 m = 10 m limits + 10 dB NOTE - This is not recommended for PSUs with a side length exceeding SONDZEICHEN 108 \f "Symbol" \s 11 /4 of the highest measured frequency.

Annex I (informative) Explanatory remark for applying criterion “B” for continuous disturbance phenomena (see clause 7.1)

Most PSUs are not very sensitive to continuous disturbance phenomena such as RF electromagnetic fields and conducted HF signals. The only observed occurrence is that for some frequencies the output voltage shows a deviation of 1% to 2%. The PSU operates as intended. The output voltage deviation is hard to suppress and is not economically feasible. The deviation is of the same magnitude as the deviation caused by a dynamic load change. Therefore it would be possible to define the test result as a performance criterion “A”, because the specifications are not altered. IEC SC22E concluded that it is better to apply the criterion “B” to indicate that there is some degradation of performance. As indicated in Table 2, the manufacturer must in that case specify the magnitude of the deviation and the frequency range in what it occurs. This gives a more accurate information to the user.

———— SEITE SONDZEICHEN 211 \f "Symbol" \s 10 CEI:1997

XXX SONDZEICHEN 211 \f "Symbol" \s 10 IEC:1998 – SEITE – 22E/60/CDV

SEITE \# "'Seite: '#' 'Seite: 2 I have a problem with the page numbers, there should be an tab but is not auto generated.. SEITE \# "'Page: '#' Page: 3 Titles of these parts are to be reviewed at the FDIS stage. SEITE \# "'Page: '#' Page: 5 This reference has been listed as it is quoted in 3.4 as modified. SEITE \# "'Page: '#' Page: 5 This reference has been listed as it is quoted in table 8(old table 9). SEITE \# "'Page: '#' Page: 5 This reference has been listed as it is quoted at the bottom of table 1(old table 2). SEITE \# "'Page: '#' Page: 6 This reference has been listed as it is quoted in the note of clause 10. SEITE \# "'Page: '#' Page: 9 It is suggested to change “not professional” to “non-professional”. Do you agree ? SEITE \# "'Page: '#' Page: 10 The numbering of the tables needs to be altered. The first table should be numbered “Table 1” and not “Table 2” and consequently the tables following renumbered. SEITE \# "'Page: '#' Page: 10 “ 1)” after “No switching”should be changed to “(note)? SEITE \# "'Page: '#' Page: 10 Instead “+” for Mandatory, “M” is proposed. Instead of “O” for Recommended, “R” is proposed. Instead of “-“ for No measurement “NA” is proposed meaning “Not applicable”. Do you agree ? YES SIR SEITE \# "'Page: '#' Page: 17 Is the numbering within the tables necessary - it may cause confusion with the subclauses ? SEITE \# "'Seite: '#' 'Seite: 18 Is this the correct reference for class I ? SEITE \# "'Page: '#' Page: 20 Is this reference correct ? SEITE \# "'Page: '#' Page: 26 See annotation 2. SEITE \# "'Page: '#' Page: 26 Please check the text of D.2 and that the English and French correspond. SEITE \# "'Page: '#' Page: 29 The layout of the items of influence has been changed in order to facilitate reading. Final DRAFT Oct 99 Checked 29.10.99 dvz WORD97 Drawings in Micrografix format 32 Pages Total

IEC SC22E WG1 INTERNAL USE ONLY

PLEASE DON’T DISTRIBUTE THIS DRAFT

EINBETTEN Designer.Drawing.7 dhk#;†gH ~yvqlgb]X ~ytoje`[ ~ytoje`[ ~ytoje`[ zsohaZSL ~wpib[TMI ~wpib[TMF ~wpie^ZSL |wrmhc]X ~ytoid_Z }xsnid_Z }xslgd^Y {tmf_XQJ ~wplgb]XSN ~wpib[WP ~wpib[TMF ~wpib[TMI xqjf_XQJ {tpib[TMF {vqjc\UN ~wpib[TMF yrkd]VOH yrkd]VOH ~wple^WPI ~wpib[TMF ~wsle^WPI ~ytmf_XQ ~wpib^WPI ~wpib[TMF yrkd]VOH ~wpib^WPI ~zupkfa\WRM tiætiætitæti t tiæg {tmf_XQJ ~wpib[TMI ~wplifa\WP ~wpib[TMF ~wple^WPI ~wpib[TMF ~wple^ZURRL |wrmhc^ zsleaZS ~wpib[TMF |wrmhc^Y {wpib[TM ~wpib[TMF ~wple^ZUPK ~wpib[TMF ~wpib[WPI |wpib[TM ~wpib[TMI {tpib[WRMH ~ytoje`[ b|,0>Í8M(yœ94Ç- a|"0.f (E甦sÊÀ‹tNY(G甧s*@E:§ $ó)8Mæ/É|&;?] k ÂctM!(L kŠB1º¦8†¦tÛ't[3hN -趖ЊnkM¯µ¶t[;hO·u ×:B' 3t rn;àr~{às~ 8 S@JÎïT )!Uh™M iBKmÚÐ B>º-?R%ÝZΫnò‘*éž b¼90~ß}ÕM>R% |&9 s;0¿~`~V ItS™'bG5;Þn“ GýxŒ><Þg–FSi|" f h. 3¥‘`×Kcƒ46Jc“46Kc‹4¶Jc›4¶Kc‡4vJc—4vKc 4öJcŸ4öK㠀 4 cŠ4&Kc’4&Jc‚4ÆKcœ4ÆJcŒ4FKc”4FJc„4†Kc˜4>—ÆPi iô“F_it’FGitF{i´“F[i´‘Fki´’FKi´Fsi4“Æ'Òh*¥ÑD U¤ñ’4*K£’4*J£‚4ÊK£œ4ÊJãEi”‘Fii<. F~iä“F^i<, < 3PX~Ž ËÏbaùy.,? &l_“Fui¼*jÒxE U¥ñ²4ªHã%iT–F%iT 8. u?]X .~òš»mq¹4VHc¥4VIcµ4ÖHc- 4ÖIc½46Hc£46Ic³4¶Hc«4¶Ic»4vHc§4vIc·4öHc¯4öIã”4NKãKiœ‘ÆWÒøZ W¥ñ‹4~•†±Ê°Òp¤áJÓ†/4RH#¥4RI#µ4ÒH#4ÒI#½42H#£42I#³4²H#«4²Iã OJã)i”FIi<- g C¥ñ¹4†Ic¸4FHc¤4FIc´4ÆHc¬4ÆIc¼4&Hc ¢4&Ic²4¦Hcª4¦Icº4fHc¦4fIc¶4æHc¹4VHc¥4VIcµ4ÖHc- 4ÖIc½46Hc£46Ic³4¶Hc«4¶Ic»4vHc§4vIc·4öHc¯4öIc¿4NKãKiœ‘ÆWÒøZ 4JHã)i<) ' y¥ñ°4òH#·4rI#, , If79v: vg ;v 1N?scÿ‡íe®ò¼þÄózÁv1gmgs SÛÙëm{z}l_ ^?;ã8Šã9Ôëeûs|{y=lWŽ{ 3ǽ3Ç¿£>?{bÏU]s lÂ~6"k#ŽE <Œß…i8sqWû_8 mx'ÆbçãÐÄ¿ßøØ1ü˜9Mb9†íŽtªÃ«¡Ql+º½1±mF·ø·8éo²kRò3¯ë˜®¦ƒ;(E 7i\ & - < /Ÿß6Š(ŽÏØkS{7nS sJ9rrm E u S±g~K6¿¹ Cb¨G~KÎ ›_m x¦ãâë>[§9Ó¿šßýÕö3sE¯~;%v~å o 2m¥´=:`, ile*U~ù\»£–ÿ +³V>få>+]+=+û¬,˜ _Toc464803636 _Toc464803636 _Toc464803637 _Toc464803637 _Toc464803638 _Toc464803638 _Toc464803639 _Toc464803639 _Toc464803640 _Toc464803640 _Toc464803641 _Toc464803641 _Toc464803642 _Toc464803642 _Toc464803643 _Toc464803643 _Toc464803644 _Toc464803644 _Toc464803645 _Toc464803645 _Toc464803646 _Toc464803646 _Toc464803647 _Toc464803647 _Toc464803648 _Toc464803648 _Toc464803649 _Toc464803649 _Toc464803650 _Toc464803650 _Toc464803651 _Toc464803651 _Toc464803652 _Toc464803652 _Toc464803653 _Toc464803653 _Toc464803654 _Toc464803654 _Toc464803655 _Toc464803655 _Toc464803656 _Toc464803656 _Toc464803657 _Toc464803657 _Toc464803658 _Toc464803658 _Toc464803659 _Toc464803659 _Toc464803660 _Toc464803660 _Toc464803661 _Toc464803661 _Toc464803662 _Toc464803662 _Toc464803663 _Toc464803663 _Toc464803664 _Toc464803664 _Toc464803665 _Toc464803665 _Toc464803666 _Toc464803666 _Toc464803667 _Toc464803667 _Toc464803668 _Toc464803668 _Toc464803669 _Toc464803669 _Toc464803670 _Toc464803670 _Toc464803671 _Toc464803671 Root Entry Root Entry WordDocument WordDocument ObjectPool ObjectPool _1001794221 _1001794221 ObjInfo ObjInfo DesignerDoc DesignerDoc DESIGNERDOC Hð¹4Xko>ô YF;aA! F kNM+Ð :¦7Pm D& \+ÔI dï<-FÉLᦠTJñrê¡!V ‘ÔV9e’ ’5=$HnR SöÉ»C¾j`ßm!»'tÉTuP @UÉ\[JP‘l7 L9†^%^ HK ú )bŽ0…)L]œ >(Î=uöZÏ–:l ]ÆW W!_î”(=?}u~RØWê DESIGNERDOC _960103216 _960103216 MathType Century Schoolbook Century Schoolbook critical~ ~~^d^~£^ critical~ ~~^d^~£^ critical~ ~~^d^~£^ critical~ ~~^d^~£^ critical~ ~~^d^~£^ measure eĀ~£~¯~~ critical~ ~~^d^~£^ Symbol Symbol Arial (MHz)Y Arial "System Microsoft Formel-Editor 2.0 CompObj CompObj ObjInfo ObjInfo Equation Native Equation Native _960103219 _960103219 DS Equation Equation.2 MathType Century Schoolbook CompObj CompObj "System Microsoft Formel-Editor 2.0 DS Equation Equation.2 ObjInfo ObjInfo Equation Native Equation Native _1001793507 _1001793507 ObjInfo ObjInfo DesignerDoc DesignerDoc 1Table 1Table SummaryInformation SummaryInformation DESIGNERDOC -y\ IJH d}.AC% K©þ§è”Š}S§”|PXŠ†‘¢Tb‹*5àG,60B“/_÷½N~ç_„Qh¤´ŠQ m+uÊ`’?äT.?åË=DG 9HWC^iɯBè»ÇP($0(] w;Ö¼¾éhmÚYlTv¤ü„h†}U8‰Aí5AYyq2pŸ eÄQw$÷(&\ý9v M´/ICtr,]'ˆ _tT‹/ëªÅ—ël»â\-~ÝB-¾æF-~c V™r][h?A zps”Vdë4ËU4Í UuA öSu¶,R´RµVmK . #U+_ ~ *£DX{Ö* @O { LX 'µù ·@¾le²l£×ÈoY[Y+ØJÔL[ 49 ÛÌ\¿Áq¥7‚™‚†]¦ÿkÙ’-k+o%ÛÞVG'߸j=²f+CÅ ~\µ |[y+à§Ez~sl lI 6 b# Ÿ Hk 0BÉDESIGNERDOC rui%`¢gE_Ñ1K·â 6<.óh/ÃûIUÉý+û%Åž W eoQ²wðº W gXg y?xl4¦TnG D¾¥Yz.f)ümJÛâß 6¡å‘M2¥0r# Fr" Lx|gp.wcóCLz *GDN±s1] b|,0>Í8M(yœ94Ç- a|"0.f (E甦sÊÀ‹tNY(G甧s*@E:§ $ó)8Mæ/É|&;?] k ÂctM!(L kŠB1º¦8†¦tÛ't[3hN -趖ЊnkM¯µ¶t[;hO·u ×:B' 3t rn;àr~{às~ 8 S@JÎïT )!Uh™M iBKmÚÐ B>º-?R%ÝZΫnò‘*éž b¼90~ß}ÕM>R% |&9 s;0¿~`~V ItS™'bG5;Þn“ GýxŒ><Þg–FSi|" f h. 3¥‘`×Kcƒ46Jc“46Kc‹4¶Jc›4¶Kc‡4vJc—4vKc 4öJcŸ4öK㠀 4 cŠ4&Kc’4&Jc‚4ÆKcœ4ÆJcŒ4FKc”4FJc„4†Kc˜4>—ÆPi iô“F_it’FGitF{i´“F[i´‘Fki´’FKi´Fsi4“Æ'Òh*¥ÑD U¤ñ’4*K£’4*J£‚4ÊK£œ4ÊJãEi”‘Fii<. F~iä“F^i<, < 3PX~Ž ËÏbaùy.,? &l_“Fui¼*jÒxE U¥ñ²4ªHã%iT–F%iT 8. u?]X .~òš»mq¹4VHc¥4VIcµ4ÖHc- 4ÖIc½46Hc£46Ic³4¶Hc«4¶Ic»4vHc§4vIc·4öHc¯4öIã”4NKãKiœ‘ÆWÒøZ W¥ñ‹4~•†±Ê°Òp¤áJÓ†/4RH#¥4RI#µ4ÒH#4ÒI#½42H#£42I#³4²H#«4²Iã OJã)i”FIi<- g C¥ñ¹4†Ic¸4FHc¤4FIc´4ÆHc¬4ÆIc¼4&Hc ¢4&Ic²4¦Hcª4¦Icº4fHc¦4fIc¶4æHc¹4VHc¥4VIcµ4ÖHc- 4ÖIc½46Hc£46Ic³4¶Hc«4¶Ic»4vHc§4vIc·4öHc¯4öIc¿4NKãKiœ‘ÆWÒøZ 4JHã)i<) ' y¥ñ°4òH#·4rI#, , If79v: vg ;v 1N?scÿ‡íe®ò¼þÄózÁv1gmgs SÛÙëm{z}l_ ^?;ã8Šã9Ôëeûs|{y=lWŽ{ 3ǽ3Ç¿£>?{bÏU]s lÂ~6"k#ŽE <Œß…i8sqWû_8 mx'ÆbçãÐÄ¿ßøØ1ü˜9Mb9†íŽtªÃ«¡Ql+º½1±mF·ø·8éo²kRò3¯ë˜®¦ƒ;(E 7i\ & - < /Ÿß6Š(ŽÏØkS{7nS sJ9rrm E u S±g~K6¿¹ Cb¨G~KÎ ›_m x¦ãâë>[§9Ó¿šßýÕö3sE¯~;%v~å o 2m¥´=:`, ile*U~ù\»£–ÿ +³V>få>+]+=+û¬,˜ NORMEINTERNATIONALE_ Dick van Zuylen iecstd.dot Dick van Zuylen Microsoft Word 8.0 DocumentSummaryInformation DocumentSummaryInformation CompObj CompObj IEC-CO, Geneva NORMEINTERNATIONALE_ _PID_GUID {B05C2F83-DEA4-11D2-87E3-0080C833A9B7} {B05C2F83-DEA4-11D2-87E3-0080C833A9B7} Microsoft Word-Dokument Standard Standard Überschrift 1 Überschrift 1 Überschrift 2 Überschrift 2 Überschrift 3 Überschrift 3 Absatz-Standardschriftart Absatz-Standardschriftart Standard Standard Überschrift 4 Überschrift 4 Überschrift 5 Überschrift 5 Überschrift 6 Überschrift 6 Überschrift 7 Überschrift 7 Überschrift 8 Überschrift 8 Überschrift 9 Überschrift 9 Absatz-Standardschriftart Absatz-Standardschriftart PARAGRAPH PARAGRAPH FIGURE-title FIGURE-title Kopfzeile Kopfzeile Kommentarzeichen Kommentarzeichen Kommentartext Kommentartext Fußzeile Fußzeile Seitenzahl Seitenzahl FOREWORD FOREWORD TABLE-title TABLE-title Fußnotentext Fußnotentext Fußnotenzeichen Fußnotenzeichen Verzeichnis 1 Verzeichnis 1 Verzeichnis 2 Verzeichnis 2 Verzeichnis 3 Verzeichnis 3 Verzeichnis 4 Verzeichnis 4 Verzeichnis 5 Verzeichnis 5 Standardeinzug Standardeinzug Verzeichnis 6 Verzeichnis 6 Verzeichnis 7 Verzeichnis 7 Verzeichnis 8 Verzeichnis 8 Verzeichnis 9 Verzeichnis 9 HEADING(Nonumber) HEADING(Nonumber) Liste 4 Liste 4 TABLE-col-heading TABLE-col-heading TERM-definition TERM-definition TERM-number TERM-number Zeilennummer Zeilennummer Listennummer 3 Listennummer 3 Liste 3 Liste 3 Aufzählungszeichen 5 Aufzählungszeichen 5 Makrotext Makrotext Endnotenzeichen Endnotenzeichen Nachrichtenkopf Nachrichtenkopf TAB_FIG_footnote TAB_FIG_footnote Reference Reference TABLE-cell TABLE-cell Liste 2 Liste 2 Aufzählungszeichen Aufzählungszeichen Aufzählungszeichen 2 Aufzählungszeichen 2 Aufzählungszeichen 3 Aufzählungszeichen 3 Aufzählungszeichen 4 Aufzählungszeichen 4 Listenfortsetzung Listenfortsetzung Listenfortsetzung 2 Listenfortsetzung 2 Listenfortsetzung 3 Listenfortsetzung 3 Listenfortsetzung 4 Listenfortsetzung 4 Listenfortsetzung 5 Listenfortsetzung 5 Liste 5 Liste 5 ANNEX-title ANNEX-title ANNEX-heading2... ANNEX-heading2... ANNEX-heading1 ANNEX-heading1 Listennummer Listennummer Listennummer 2 Listennummer 2 MAIN-TITLE MAIN-TITLE Basic Paragraph Basic Paragraph Listennummer 4 Listennummer 4 Listennummer 5 Listennummer 5 TABLE-centered TABLE-centered Main title Main title Basic Paragraph indent 1 Basic Paragraph indent 1 Figure/Table header Figure/Table header Table Column1 Table Column1 Table Column2 Table Column2 Beschriftung Beschriftung Table text Table text Main Title 2 Main Title 2 Normative Normative adresse adresse Textkörper Textkörper Kopfzeile Kopfzeile Fußzeile Fußzeile Kommentarzeichen Kommentarzeichen Kommentartext Kommentartext Index 1 Index 1 Dick van Zuylen Dick van Zuylen Information Systems Dep. Information Systems Dep.గ Unknown Unknown Dick van Zuylen Dick van Zuylen Information Systems Dep. Information Systems Dep. DRAFT FDIS DRAFT FDIS Arial Black Arial Black ÿ ᄋĀ _Hlt460311923 _Hlt460312024 _Toc464803636 _Toc464803637 _Toc464803638 OLE_LINK1 _Ref351221913 _Toc351222692 _Toc351223394 _Toc351225365 _Toc352942429 _Toc464803639 _Ref351221943 _Toc351222693 _Toc351223395 _Toc351225366 _Toc352942430 _Toc464803640 _Toc352925194 _Toc352942431 _Toc354136366 _Toc354416393 _Toc360299059 _Toc360804540 _Toc352925195 _Toc352942432 _Toc354136367 _Toc354416394 _Toc360299060 _Toc360804541 _Toc352925196 _Toc352942433 _Toc354136368 _Toc354416395 _Toc360299061 _Toc360804542 _Toc352925197 _Toc352942434 _Toc354136369 _Toc354416396 _Toc360299062 _Toc360804543 _Toc351222696 _Toc351223398 _Toc351225369 _Toc352925198 _Toc352942435 _Toc354136370 _Toc354416397 _Toc360299063 _Toc360804544 _Toc352925199 _Toc352942436 _Toc354136371 _Toc354416398 _Toc360299064 _Toc360804545 _Toc351222697 _Toc351223399 _Toc351225370 _Toc352925200 _Toc352942437 _Toc354136372 _Toc354416399 _Toc360299065 _Toc360804546 _Toc351222698 _Toc351223400 _Toc351225371 _Toc352925201 _Toc352942438 _Toc354136373 _Toc354416400 _Toc360299066 _Toc360804547 _Toc351222699 _Toc351223401 _Toc351225372 _Toc352925202 _Toc352942439 _Toc354136374 _Toc354416401 _Toc360299067 _Toc360804548 _Toc351222700 _Toc351223402 _Toc351225373 _Toc352925203 _Toc352942440 _Toc354136375 _Toc354416402 _Toc360299068 _Toc360804549 _Toc351222701 _Toc351223403 _Toc351225374 _Toc352925204 _Toc352942441 _Toc354136376 _Toc354416403 _Toc360299069 _Toc360804550 _Toc351222702 _Toc351223404 _Toc351225375 _Toc352925205 _Toc352942442 _Toc354136377 _Toc354416404 _Toc360299070 _Toc360804551 _Toc351222703 _Toc351223405 _Toc351225376 _Toc352925206 _Toc352942443 _Toc354136378 _Toc354416405 _Toc360299071 _Toc360804552 _Toc351222704 _Toc351223406 _Toc351225377 _Toc352925207 _Toc352942444 _Toc354136379 _Toc354416406 _Toc360299072 _Toc360804553 _Toc351222705 _Toc351223407 _Toc351225378 _Toc352925208 _Toc352942445 _Toc354136380 _Toc354416407 _Toc360299073 _Toc360804554 _Toc351222706 _Toc351223408 _Toc351225379 _Toc352925209 _Toc352942446 _Toc354136381 _Toc354416408 _Toc360299074 _Toc360804555 _Toc351222707 _Toc351223409 _Toc351225380 _Toc352925210 _Toc352942447 _Toc354136382 _Toc354416409 _Toc360299075 _Toc360804556 _Toc351222708 _Toc351223410 _Toc351225381 _Toc352925211 _Toc352942448 _Toc354136383 _Toc354416410 _Toc360299076 _Toc360804557 _Toc351222709 _Toc351223411 _Toc351225382 _Toc352925212 _Toc352942449 _Toc354136384 _Toc354416411 _Toc360299077 _Toc360804558 _Toc351222710 _Toc351223412 _Toc351225383 _Toc352925213 _Toc352942450 _Toc354136385 _Toc354416412 _Toc360299078 _Toc360804559 _Toc351222711 _Toc351223413 _Toc351225384 _Toc352925214 _Toc352942451 _Toc354136386 _Toc354416413 _Toc360299079 _Toc360804560 _Toc351222712 _Toc351223414 _Toc351225385 _Toc351222714 _Toc351223416 _Toc351225387 _Toc352925216 _Toc352942453 _Toc354136388 _Toc354416415 _Toc360299081 _Toc360804562 _Toc351222715 _Toc351223417 _Toc351225388 _Toc352925217 _Toc352942454 _Toc354136389 _Toc354416416 _Toc360299082 _Toc360804563 _Toc351222716 _Toc351223418 _Toc351225389 _Toc352925218 _Toc352942455 _Toc354136390 _Toc354416417 _Toc360299083 _Toc360804564 _Toc351222717 _Toc351223419 _Toc351225390 _Toc352925219 _Toc352942456 _Toc354136391 _Toc354416418 _Toc360299084 _Toc360804565 _Toc351222718 _Toc351223420 _Toc351225391 _Toc352925220 _Toc352942457 _Toc354136392 _Toc354416419 _Toc360299085 _Toc360804566 _Toc351222719 _Toc351223421 _Toc351225392 _Toc352925221 _Toc352942458 _Toc354136393 _Toc354416420 _Toc360299086 _Toc360804567 _Toc351222720 _Toc351223422 _Toc351225393 _Toc352925222 _Toc352942459 _Toc354136394 _Toc354416421 _Toc360299087 _Toc360804568 _Toc351222721 _Toc351223423 _Toc351225394 _Toc352925223 _Toc352942460 _Toc354136395 _Toc354416422 _Toc360299088 _Toc360804569 _Toc351222722 _Toc351223424 _Toc351225395 _Toc352925224 _Toc352942461 _Toc354136396 _Toc354416423 _Toc360299089 _Toc360804570 _Toc351222723 _Toc351223425 _Toc351225396 _Toc352925225 _Toc352942462 _Toc354136397 _Toc354416424 _Toc360299090 _Toc360804571 _Toc351222724 _Toc351223426 _Toc351225397 _Ref351221973 _Toc351222725 _Toc351223427 _Toc351225398 _Toc352942463 _Toc464803641 _Ref351221997 _Toc351222726 _Toc351223428 _Toc351225399 _Toc352942464 _Toc464803642 _Toc464803643 _Toc464803644 _Ref351222027 _Toc351222727 _Toc351223429 _Toc351225400 _Toc352942465 _Toc464803645 _Toc352942466 _Toc464803646 _Toc352942467 _Toc352942468 _Toc352942469 _Ref351222048 _Toc351222728 _Toc351223430 _Toc351225401 _Toc352942470 _Toc464803647 _Toc351222729 _Toc351223431 _Toc351225402 _Toc352942471 _Toc351222730 _Toc351223432 _Toc351225403 _Toc352942472 _Toc351222731 _Toc351223433 _Toc351225404 _Toc352942473 _Toc352942474 _Ref351222071 _Toc351222732 _Toc351223434 _Toc351225405 _Toc464803648 _Toc352942475 _Toc351222737 _Toc351223439 _Toc351225410 _Toc352942476 _Ref351222168 _Toc351222738 _Toc351223440 _Toc351225411 _Toc352942477 _Toc464803649 _Toc351222739 _Toc351223441 _Toc351225412 _Toc352942478 _Toc351222740 _Toc351223442 _Toc351225413 _Toc352942479 _Toc351222741 _Toc351223443 _Toc351225414 _Toc352942480 _Toc464803650 _Toc464803651 _Ref351222252 _Toc351222743 _Toc351223445 _Toc351225416 _Toc352942482 _Toc464803652 _Ref351222271 _Toc351222744 _Toc351223446 _Toc351225417 _Toc352942483 _Toc351222745 _Toc351223447 _Toc351225418 _Toc352942484 _Toc351222746 _Toc351223448 _Toc351225419 _Toc352942485 _Ref351222300 _Toc351222747 _Toc351223449 _Toc351225420 _Toc352942486 _Toc464803653 _Toc351222748 _Toc351223450 _Toc351225421 _Toc352942487 _Toc464803654 _Toc351222749 _Toc351223451 _Toc351225422 _Toc352942488 _Toc464803655 _Toc351222750 _Toc351223452 _Toc351225423 _Toc352942489 _Toc464803656 _Toc351222751 _Toc351223453 _Toc351225424 _Toc352942490 _Toc464803657 _Toc464803658 _Toc352942491 _Ref351222317 _Toc351222752 _Toc351223454 _Toc351225425 _Toc464803659 _Toc352942492 _Toc464803660 _Toc464803661 _Toc464803662 _Toc352942495 _Toc464803663 _Toc422892686 _Toc422892687 _Toc352942496 _Toc464803664 _Toc352942497 _Toc464803665 _Toc352942498 _Toc464803666 _Toc422892691 _Toc422892692 _Toc422892693 _Toc352942499 _Toc464803667 _Toc352942500 _Toc464803668 _Toc352942501 _Toc464803669 _Toc464803670 _Toc464803671 _Hlt460311923 _Hlt460312024 _Toc464803636 _Toc464803637 _Toc464803638 OLE_LINK1 _Ref351221913 _Toc351222692 _Toc351223394 _Toc351225365 _Toc352942429 _Toc464803639 _Ref351221943 _Toc351222693 _Toc351223395 _Toc351225366 _Toc352942430 _Toc464803640 _Toc352925194 _Toc352942431 _Toc354136366 _Toc354416393 _Toc360299059 _Toc360804540 _Toc352925195 _Toc352942432 _Toc354136367 _Toc354416394 _Toc360299060 _Toc360804541 _Toc352925196 _Toc352942433 _Toc354136368 _Toc354416395 _Toc360299061 _Toc360804542 _Toc352925197 _Toc352942434 _Toc354136369 _Toc354416396 _Toc360299062 _Toc360804543 _Toc351222696 _Toc351223398 _Toc351225369 _Toc352925198 _Toc352942435 _Toc354136370 _Toc354416397 _Toc360299063 _Toc360804544 _Toc352925199 _Toc352942436 _Toc354136371 _Toc354416398 _Toc360299064 _Toc360804545 _Toc351222697 _Toc351223399 _Toc351225370 _Toc352925200 _Toc352942437 _Toc354136372 _Toc354416399 _Toc360299065 _Toc360804546 _Toc351222698 _Toc351223400 _Toc351225371 _Toc352925201 _Toc352942438 _Toc354136373 _Toc354416400 _Toc360299066 _Toc360804547 _Toc351222699 _Toc351223401 _Toc351225372 _Toc352925202 _Toc352942439 _Toc354136374 _Toc354416401 _Toc360299067 _Toc360804548 _Toc351222700 _Toc351223402 _Toc351225373 _Toc352925203 _Toc352942440 _Toc354136375 _Toc354416402 _Toc360299068 _Toc360804549 _Toc351222701 _Toc351223403 _Toc351225374 _Toc352925204 _Toc352942441 _Toc354136376 _Toc354416403 _Toc360299069 _Toc360804550 _Toc351222702 _Toc351223404 _Toc351225375 _Toc352925205 _Toc352942442 _Toc354136377 _Toc354416404 _Toc360299070 _Toc360804551 _Toc351222703 _Toc351223405 _Toc351225376 _Toc352925206 _Toc352942443 _Toc354136378 _Toc354416405 _Toc360299071 _Toc360804552 _Toc351222704 _Toc351223406 _Toc351225377 _Toc352925207 _Toc352942444 _Toc354136379 _Toc354416406 _Toc360299072 _Toc360804553 _Toc351222705 _Toc351223407 _Toc351225378 _Toc352925208 _Toc352942445 _Toc354136380 _Toc354416407 _Toc360299073 _Toc360804554 _Toc351222706 _Toc351223408 _Toc351225379 _Toc352925209 _Toc352942446 _Toc354136381 _Toc354416408 _Toc360299074 _Toc360804555 _Toc351222707 _Toc351223409 _Toc351225380 _Toc352925210 _Toc352942447 _Toc354136382 _Toc354416409 _Toc360299075 _Toc360804556 _Toc351222708 _Toc351223410 _Toc351225381 _Toc352925211 _Toc352942448 _Toc354136383 _Toc354416410 _Toc360299076 _Toc360804557 _Toc351222709 _Toc351223411 _Toc351225382 _Toc352925212 _Toc352942449 _Toc354136384 _Toc354416411 _Toc360299077 _Toc360804558 _Toc351222710 _Toc351223412 _Toc351225383 _Toc352925213 _Toc352942450 _Toc354136385 _Toc354416412 _Toc360299078 _Toc360804559 _Toc351222711 _Toc351223413 _Toc351225384 _Toc352925214 _Toc352942451 _Toc354136386 _Toc354416413 _Toc360299079 _Toc360804560 _Toc351222712 _Toc351223414 _Toc351225385 _Toc351222714 _Toc351223416 _Toc351225387 _Toc352925216 _Toc352942453 _Toc354136388 _Toc354416415 _Toc360299081 _Toc360804562 _Toc351222715 _Toc351223417 _Toc351225388 _Toc352925217 _Toc352942454 _Toc354136389 _Toc354416416 _Toc360299082 _Toc360804563 _Toc351222716 _Toc351223418 _Toc351225389 _Toc352925218 _Toc352942455 _Toc354136390 _Toc354416417 _Toc360299083 _Toc360804564 _Toc351222717 _Toc351223419 _Toc351225390 _Toc352925219 _Toc352942456 _Toc354136391 _Toc354416418 _Toc360299084 _Toc360804565 _Toc351222718 _Toc351223420 _Toc351225391 _Toc352925220 _Toc352942457 _Toc354136392 _Toc354416419 _Toc360299085 _Toc360804566 _Toc351222719 _Toc351223421 _Toc351225392 _Toc352925221 _Toc352942458 _Toc354136393 _Toc354416420 _Toc360299086 _Toc360804567 _Toc351222720 _Toc351223422 _Toc351225393 _Toc352925222 _Toc352942459 _Toc354136394 _Toc354416421 _Toc360299087 _Toc360804568 _Toc351222721 _Toc351223423 _Toc351225394 _Toc352925223 _Toc352942460 _Toc354136395 _Toc354416422 _Toc360299088 _Toc360804569 _Toc351222722 _Toc351223424 _Toc351225395 _Toc352925224 _Toc352942461 _Toc354136396 _Toc354416423 _Toc360299089 _Toc360804570 _Toc351222723 _Toc351223425 _Toc351225396 _Toc352925225 _Toc352942462 _Toc354136397 _Toc354416424 _Toc360299090 _Toc360804571 _Toc351222724 _Toc351223426 _Toc351225397 _Ref351221973 _Toc351222725 _Toc351223427 _Toc351225398 _Toc352942463 _Toc464803641 _Ref351221997 _Toc351222726 _Toc351223428 _Toc351225399 _Toc352942464 _Toc464803642 _Toc464803643 _Toc464803644 _Ref351222027 _Toc351222727 _Toc351223429 _Toc351225400 _Toc352942465 _Toc464803645 _Toc352942466 _Toc464803646 _Toc352942467 _Toc352942468 _Toc352942469 _Ref351222048 _Toc351222728 _Toc351223430 _Toc351225401 _Toc352942470 _Toc464803647 _Toc351222729 _Toc351223431 _Toc351225402 _Toc352942471 _Toc351222730 _Toc351223432 _Toc351225403 _Toc352942472 _Toc351222731 _Toc351223433 _Toc351225404 _Toc352942473 _Toc352942474 _Ref351222071 _Toc351222732 _Toc351223434 _Toc351225405 _Toc464803648 _Toc352942475 _Toc351222737 _Toc351223439 _Toc351225410 _Toc352942476 _Ref351222168 _Toc351222738 _Toc351223440 _Toc351225411 _Toc352942477 _Toc464803649 _Toc351222739 _Toc351223441 _Toc351225412 _Toc352942478 _Toc351222740 _Toc351223442 _Toc351225413 _Toc352942479 _Toc351222741 _Toc351223443 _Toc351225414 _Toc352942480 _Toc464803650 _Toc464803651 _Ref351222252 _Toc351222743 _Toc351223445 _Toc351225416 _Toc352942482 _Toc464803652 _Ref351222271 _Toc351222744 _Toc351223446 _Toc351225417 _Toc352942483 _Toc351222745 _Toc351223447 _Toc351225418 _Toc352942484 _Toc351222746 _Toc351223448 _Toc351225419 _Toc352942485 _Ref351222300 _Toc351222747 _Toc351223449 _Toc351225420 _Toc352942486 _Toc464803653 _Toc351222748 _Toc351223450 _Toc351225421 _Toc352942487 _Toc464803654 _Toc351222749 _Toc351223451 _Toc351225422 _Toc352942488 _Toc464803655 _Toc351222750 _Toc351223452 _Toc351225423 _Toc352942489 _Toc464803656 _Toc351222751 _Toc351223453 _Toc351225424 _Toc352942490 _Toc464803657 _Toc464803658 _Toc352942491 _Ref351222317 _Toc351222752 _Toc351223454 _Toc351225425 _Toc464803659 _Toc352942492 _Toc464803660 _Toc464803661 _Toc464803662 _Toc352942495 _Toc464803663 _Toc422892686 _Toc422892687 _Toc352942496 _Toc464803664 _Toc352942497 _Toc464803665 _Toc352942498 _Toc464803666 _Toc422892691 _Toc422892692 _Toc422892693 _Toc352942499 _Toc464803667 _Toc352942500 _Toc464803668 _Toc352942501 _Toc464803669 _Toc464803670 _Toc464803671 క Dick van ZuylenHC:\windows\TEMP\AutoWiederherstellen-Speicherung von 61204- 3E_990820.asd Dick van ZuylenHC:\windows\TEMP\AutoWiederherstellen-Speicherung von 61204- 3E_990820.asd Dick van ZuylenHC:\windows\TEMP\AutoWiederherstellen-Speicherung von 61204- 3E_990820.asd Dick van ZuylenHC:\windows\TEMP\AutoWiederherstellen-Speicherung von 61204- 3E_990820.asd Dick van Zuylen3\\SERVER\SERVER\22E_60_CDV\FDIS\61204-3E_990820.doc Dick van Zuylen3\\SERVER\SERVER\22E_60_CDV\FDIS\61204-3E_990820.doc Dick van Zuylen8\\SERVER\SERVER\22E_60_CDV\FDIS\61204-3E_fdis_011199.doc Dick van Zuylen8\\SERVER\SERVER\22E_60_CDV\FDIS\61204-3E_fdis_011199.doc Dick van Zuylen8\\SERVER\SERVER\22E_60_CDV\FDIS\61204-3E_fdis_011199.doc Dick van Zuylen8\\SERVER\SERVER\22E_60_CDV\FDIS\61204-3E_fdis_011199.doc Dick van Zuylen8\\SERVER\SERVER\22E_60_CDV\FDIS\61204-3E_fdis_011199.doc Dick van Zuylen8\\SERVER\SERVER\22E_60_CDV\FDIS\61204-3E_fdis_011199.doc Dick van Zuylen2\\SERVER\SERVER\COMMON_AREA\email-out\12043EDF.doc Dick van Zuylen2\\SERVER\SERVER\COMMON_AREA\email-out\12043EDF.doc Dick van Zuylen2\\SERVER\SERVER\COMMON_AREA\email-out\12043EDF.doc Dick van Zuylen2\\SERVER\SERVER\COMMON_AREA\email-out\12043EDF.doc Dick van Zuylen2\\SERVER\SERVER\COMMON_AREA\email-out\12043EDF.doc Dick van Zuylen2\\SERVER\SERVER\COMMON_AREA\email-out\12043EDF.doc Dick van Zuylen2\\SERVER\SERVER\COMMON_AREA\email-out\12043EDF.doc û Dick van Zuylen2\\SERVER\SERVER\COMMON_AREA\email-out\12043EDF.doc  @HP LaserJet 5P/5MP PostScript PSCRIPT HP LaserJet 5P/5MP PostScript HP LaserJet 5P/5MP PostScript Benutzerdefinierte Seite 1 Benutzerdefinierte Seite 2 Benutzerdefinierte Seite 3 HP LaserJet 5P/5MP PostScript Benutzerdefinierte Seite 1 Benutzerdefinierte Seite 2 Benutzerdefinierte Seite 3 Times New Roman Times New Roman Symbol Symbol Courier New Courier New #\\OFFICE\MODELS\template\iecstd.dot #\\OFFICE\MODELS\template\iecstd.dot NORMEINTERNATIONALE_ NORMEINTERNATIONALE_ Dick van Zuylen Dick van Zuylen Dick van Zuylen Dick van Zuylen Word.Document.8

Recommended publications