UL 1993, Edition - 5, Issue/Revised Date - 1/27/2017

Total Page:16

File Type:pdf, Size:1020Kb

UL 1993, Edition - 5, Issue/Revised Date - 1/27/2017

4/25/2017 SUMMARY OF REQUIREMENTS FOR UL 1993, Edition - 5, Issue/Revised Date - 1/27/2017 Standard for Self-Ballasted Lamps and Lamp Adapters

This document is derived from the following Standard Development Organization (SDO) bulletin(s) or other documentation publicly available to UL subscribers: Standard Development Organization Document Type Document Designation Date (SDO) (proposal, bulletin, etc) UL Proposal Bulletin Subject 1993 2015-08-07, 2016-10-14

Primary motivator for the Standards revision Technology

CCNs Impacted OOLR, OOLR2, OOLR7, OOLR 8, OOLV, OOLV2, OOLV7, OOLV8

The following is a summary of the revised/new certification requirements.

Action is not required for current certified products and the new/revised certification requirements will be applied in evaluation of the new and revised products effective April 15, 2018.

Section Summary of requirements Paragraph Clause 8.2.2 For devices intended for use on a dimmer circuit, the input current measured during the test of Clause 8.12.2.1 shall not be more than 110 percent of the marked rating. Section Summary of requirements Paragraph Clause SA8.19.4 During the measurement, any mechanical interlock mechanism intended to prevent current from flowing through the lamp during its insertion or removal shall be defeated. However, an interlock mechanism located on the free end of the lamp under test is allowed to operate normally if it meets all the following criteria:

a) Actuators shall be located only on the face of the lamp bases and have a normally- open, momentary-type action so that they automatically engage and disengage when the lamp is inserted or removed from the luminaire, respectively;

b) Actuators shall require a force of no more than 4.45 N (1 lbf) to recess completely into the lamp base so that they are flush with the lamp base surface;

c) The actuator shall be made from or externally encapsulated by an insulating material that complies with the requirements for at least basic insulation;

d) The actuator shall be shaped and located to reduce the likelihood of accidental engagement by an end user during lamp insertion into or removal from an energized luminaire. The actuator is considered to comply with this requirement if it cannot be engaged by a 50.8 mm (2 inch) diameter rigid sphere regardless of how it contacts the lamp, see Figure SA8.2; and

e) The interlock mechanism shall endure 500 actuation cycles under its intended electrical load without resulting in mechanical or electrical damage to the lamp or mechanism. The following is Summary of Action Not Required new/revised certification requirements effective April 15, 2018 based on revisions dated January 27, 2017 to the 5th Edition of the Standard.

PROPOSALS FROM 2015-08-07 AND 2016-10-14 BULLETINS EFFECT ON EXISTING CERTIFICATIONS

1a) Proposed clarification of table 5.2, Ratings of polymeric materials None. Table 5.2 revised for clarity.

1b) Proposed clarification to table 5.3, Weight and moment limitation None. Typographical error corrected.

1c) Proposed revision to clarify the requirements in clause 6.1.2 are for a device base for damp None. Existing practice per 2013-03-08 CRD. or wet locations

1d) Proposed addition of clause 6.2.5 to add stainless steel as a material for current carrying None. Alternate material added. parts

1e) Proposed revision to clause 6.4.5 to add a test value for the Limited short circuit test for None. Existing practice per 2013-09-05 CRD. fusing resistors

1f) Proposed revisions to table 8.2 to add alternate test methods for determining the softening None. Existing practice per 2013-05-21 CRD. point of potting compounds and editorial updates

1g) Proposed revisions to clause 8.13.1 to revise the relative humidity tolerance for the Humidity None. Existing practice per 2013-05-23 CRD. conditioning test

1h) Proposed revisions to clauses 4.5.2.3, 5.3.3.1; addition of clause 8.19, figure 8.8; to add a None. Existing practice per 2013-05-24 CRD. test method for determining risk of fire within a circuit

1i) Proposed revisions to table 10.1 and clause 10.2.6 to revise the markings for lamps None. Existing practice per 2013-05-17 CRD. containing mercury

1j) Proposed revisions to table SA8.1, clauses SA8.8.2; addition of clauses SA8.8.3, SA8.23, None. Existing practice per 2013-06-12 CRD. figure SA8.3, table SA8.2; to add the Rigidity after drop test requirements

1k) Proposed revisions to update table A.1 to add UL 60384-14 to the standards for components None. Annex A updated. table in Annex A 1l) Proposed addition of clauses 3.6A, 8.12.1.3, 10.2.7 and SA10.2.7, revisions to tables 10.1 None. Alternate dimmable lamp markings and SA10.1, figure F.1 and clauses 8.12.1.1, 8.12.1.2, 8.12.2.1, 8.12.3.1, F.3; add pictograms to added; other pictograms were existing practice Annex F and addition of requirements to address dimmable lamps that do not function on per 2013-05-22 CRD. traditional dimmers

1m) Proposed addition of Supplement SB, revisions to clause 2.1; to add requirements for solid- None. Existing practice, see 2013-05-16 CRD. state lamps containing silicone fluid

1n) Proposed addition of Supplement SC and revision to clauses SA6.13.1, SA6.13.3, None. Existing practice per 2015-02-20 CRD. SA6.13.10; to add requirements for evaluating tubular LED lamps as direct replacements for specific fluorescent lamps

1o) Proposed revision of clause SA6.11.2; addition of clause SA6.15, SA8.24, tables SA6.2, None. Existing practice. SA6.3, figure SA8.4; to revise the double insulation requirements for LED lamps

1p) Proposed addition of clause SA8.19.4 and figure SA8.2, to add requirements for interlock New construction and test requirement, switches in double-ended tubular LED lamps clause SA8.19.4.

1q) Proposed revision of clauses 2.1 and SA6.3.3 and table A.1; to revise the referenced None. Erroneous reference corrected. standard for printed wiring boards (United States Only)

2. Proposed addition of clause 8.2.1.1 to revise the marked current for dimmable CFL and LED New test requirement, clause 8.2.2. lamps