UPS Proposal Document: Avaya 6000 VA Online UPS with L6-30 and L14-30 PPDM PRICING OVERVIEW (AVAYA NPL) Item Com Code NPL Quantity Total 6000 VA UPS 700404627 $4,399.00 PPDM, L6-30R & L14-30R 700315120 $849.00 Extended Battery Module (EBM) 700404726 $1,049.00 Extended Battery Cabinet (EBC240) 700404718 $9,249.00 05146793- Alarm Relay Card 4101* $149.00 Extended Power Distribution Module (PDM03); L14-30P with (4) 5-15R, (1) L6-30R, (1) L6-20R 407483361 $618.00 Extended Power Distribution Module (PDM05); L5-30P with (8) 5-15R 407483353 $650.00 Extended Power Distribution Module (PDM06); L5-30P with (2) 5-15R and (1) 5-50R 407505858 $650.00

Battery Extension Cable for EBM and EBC240 Call (48 in. long) N/A 800.322.4877 Seismic Kit (Holds UPS, PPDM, EBM) 700404742 $549.00 4-Post Rail Kit 700404734 $149.00 *Part number for Business Partners. PRODUCT OVERVIEW The Avaya 6000 VA online UPS provides the ultimate power protection for your telecommunications systems and equipment. With its rigorous online design, the Avaya UPS provides complete isolation from power disturbances to protect your customer’s data and equipment. Avaya UPS Features & Benefits . Isolates connected equipment from all incoming power problems to provide the highest degree of protection . Doubles battery service life and gives you advanced warning of the end of useful battery life with Advanced Battery Management (ABM) technology . Prolongs backup time with optional extended battery solutions . Adapts to rack and standalone tower applications with versatile form factor . Provides monitoring capabilities with standard Web/SNMP card . Allows you to service the UPS without shutting down connected equipment with the PowerPass Distribution Module (PPDM)

The 6000 VA UPS can be mounted in a rack . . .

800.322.4877 Page 1 of 7 powerware.com/avaya . . . or used as a tower unit.

Top Reasons to Buy an Avaya UPS When it comes to providing the best possible power protection solution for your Avaya telecommunications equipment, select the best--an Avaya UPS.

. Online, Double-conversion Technology All Avaya UPS models feature a rugged, online design where power is completely regenerated before reaching the connected load so that no disturbances reach the connected equipment. An Avaya UPS provides complete protection from all nine common power problems. In addition, the online design is compatible with generators. . Advanced Battery Management (ABM) Avaya UPS models feature Advanced Battery Management, which doubles battery service life, optimizes recharge time, and provides advanced warning of the end of useful battery life. With increased battery life, you won't need to replace the batteries as quickly. As a result, the total cost of ownership for an Avaya UPS is reduced. In addition, most competitive UPS models use an LED to indicate that the batteries are dead with no advanced notice. . Extended Backup Times Avaya has custom solutions designed to provide up to 8 hours of backup time. Competitive UPS offerings are often difficult to configure for long runtimes. . Avaya Authorized and Approved Each Avaya labeled UPS is designed and tested to meet the rigorous Avaya specifications of telecommunications and ancillary equipment. . Web/SNMP Card Avaya models are equipped with the Web/SNMP card for advanced communication and monitoring capabilities.

Web/SNMP Card Included with the 6000 VA UPS, the Web/SNMP card enables you to monitor and control remote UPSs from web browsers or industry standard network management systems. The Web/SNMP card supports real-time web and SNMP (Simple Network Management Protocol) communication over 10/100BaseT Ethernet connections and serves as a power-protected switching hub to support three additional 10/100BaseT links.

800.322.4877 Page 2 of 7 powerware.com/avaya PowerPass Distribution Modules (PPDM) The PPDMs are designed to enhance the reliability and flexibility of the 6000 VA UPS. With an integrated maintenance bypass switch, the PPDM allows you to upgrade or replace the UPS without shutting down protected equipment. It also provides various output receptacle options. The default module is the PPDM, L5-30R, but you can select one of the other three models depending on your application requirements.

LanSafe Software Each Avaya UPS ships with a CD containing LanSafe software, which delivers comprehensive support including graceful, remote shutdown of UPS units and network monitoring tools. LanSafe supports all major operating systems.

LanSafe Features and Benefits . Patent pending Cost $avings Calculator allows you to determine overall savings resulting from the LanSafe monitoring system . Exclusive Stealth Mode Operation enables LanSafe to run in the background without visual traces . 3-D PowerScope and ControlRoom views eliminate the guesswork from UPS metering and status information . History View provides around-the-clock visual representation of the system event log in calendar format

ADDITIONAL PRODUCT INFORMATION Avaya UPS web site: http://www.powerware.com/AVAYA/USA/Products/6000va.asp

Model Selection Guide Input Voltage Output Input Output Model SAP Code (Vac) Voltage (Vac) Connection Connections RS9RM 6000 VA See PPDM See PPDM See PPDM See PPDM 700404627 UPS below below below below (1) L6-30R, PPDM, L6-30R 700315120 208-240 208-240/120 L6-30P (1) L-14-30R, & L14-30R (4) 5-15R Optional Batteries EBM 700404726 - - - - EBC240 700404718 - - - - Battery Extender None (call 800.322.4877 for details). Cable, 48 in.

800.322.4877 Page 3 of 7 powerware.com/avaya Dimensions & Weights

6000 VA UPS with PPDM and EBM in Tower Configuration

Dimensions Installed Shipping # of Shipping Configuration (H x W x D) in. Weight (lb.) Weight (lb.) Boxes1 Vertical Tower Configuration UPS + PPDM 17.4 x 13.7 x 26.9 300.0 332.0 4 UPS + PPDM + 1 EBM 17.4 x 18.8 x 26.9 454.0 498.0 5 UPS + PPDM + 2 EBMs 17.4 x 23.9 x 26.9 608.0 664.0 6 UPS + PPDM + 3 EBMs 17.4 x 29.0 x 26.9 762.0 830.0 7 UPS + PPDM + 4 EBMs 17.4 x 34.1 x 26.9 916.0 996.0 8 With Extended Battery Cabinets (EBC240) UPS + PPDM + 2 EBCs 28.1 x 64.7 x 76.1 2140.0 2342.0 4 + 2 pallets UPS + PPDM + 3 EBCs 28.1 x 90.2 x 76.1 3110.0 3347.0 4 + 3 pallets UPS + PPDM + 4 EBCs 28.1 x 115.7 x 76.1 4080.0 4352.0 4 + 4 pallets UPS + PPDM + 5 EBCs 28.1 x 141.2 x 76.1 5050.0 5357.0 4 + 5 pallets UPS + PPDM + 6 EBCs 28.1 x 166.7 x 76.1 6020.0 6362.0 4 + 6 pallets Rack and Horizontal Tower Configuration UPS + PPDM 13.7 (8U) x 17.4 x 26.9 300.0 332.0 4 UPS + PPDM + 1 EBM 18.8 (11U) x 17.4 x 26.9 454.0 498.0 5 UPS + PPDM + 2 EBMs 23.9 (14U) x 17.4 x 26.9 608.0 664.0 6 UPS + PPDM + 3 EBMs 29.9 (17U) x 17.4 x 26.9 762.0 830.0 7 UPS + PPDM + 4 EBMs 34.1 (20U) x 17.4 x 26.9 916.0 996.0 8 Individual Modules UPS 8.6 (5U) x 17.4 x 26.9 197.0 217.0 3 PPDM 5.1 (3U) x 17.4 x 26.9 103.0 115.0 1 EBM 5.1 (3U) x 17.4 x 26.9 154.0 166.0 1 EBC240 28.1 x 25.5 x 28.2 970.0 1005.0 1 pallet Seismic Kit 21.8 (11U) x 18.5 x 25.5 31.0 41.0 1 EPDM 5.25 x 13.0 x 8.01 7.0 10.0 1 1. Two battery trays are shipped in boxes separate from the UPS.

800.322.4877 Page 4 of 7 powerware.com/avaya Rear Panel

Battery Backup Times

UPS with front panels removed showing two internal battery trays Standard Internal Batteries & Extended Battery Modules (EBM)1 Standard Internal Load (1) EBM (2) EBMs (3) EBMs (4) EBMs Batteries 2000 VA/1400W 480 – – – – 3000 VA/2100W 300 480 – – – 4000 VA/2800W 240 360 480 – – 5000 VA/3500W 180 300 420 480 – 6000 VA/4200W 120 240 300 420 480

Standard Internal Batteries & Extended Battery Cabinets (EBC)1 Load (2) EBC (3) EBC (4) EBC (5) EBC 2000 VA/1400W 660 – – – 3000 VA/2100W 387 576 – – 4000 VA/2800W 245 480 – – 5000 VA/3500W 190 360 600 – 6000 VA/4200W 135 284 446 590 1. These tables provide typical information. Runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.

800.322.4877 Page 5 of 7 powerware.com/avaya Additional Specifications1 Electrical Input Power Rating 6000 VA/4200 watts Nominal Voltage 208V (auto-sensing 208-240V) Voltage Range 160-288V nominal Nominal Frequency 50/60 Hz, auto-sensing Dedicated Circuit Breaker Rating 30A Power Draw of UPS 40A Noise Filtering MOVs and line filter for nominal and common mode noise Connections L6-30P detachable input line cord Power Factor >0.96 Electrical Output Nominal Voltage 208-240/120 Vac Voltage Regulation ±3% (nominal for normal and battery modes) Voltage Waveform Sine wave Output Receptacles (1) L6-30R, (1) L14-30R, (4) 5-15R Communications Web/SNMP Card Manage and monitor the UPS via the internet or SNMP protocol; included as standard Communication Ports USB and serial ports standard NetWatch Clients CD Bundled with UPS Software Suite CD Power management software for all major operating systems included Environment & Safety Operating Temperature 32 to 104°F (0 to 40°C) Storage Temperature 32 to 77°F (0 to 25°C ) Transit Temperature -13 to 131°F (-25 to 55°C ) Relative Humidity 5-95% noncondensing Operating Altitude Up to 3,000 meters above sea level Transit Altitude Up to 10,000 meters above sea level Heat Dissipation 2066 BTU/hr, maximum Audible Noise <50 dBA during normal mode; <60 dBA during battery mode Leakage Current <0.6 mA Surge Suppression ANSI C62.41 Category B3; EN 61000-4-5 Level 3, Criteria B Safety Conformance UL1778; CAN/CSA C22.2, No. 107.1, 107.2; EN 50091-1-1 and IEC 60950; NOM-019-SCFUI Agency Markings UL, cUL, NOM-NYCE, CE, EMC (Class A) EN 50091-2, FCC Part 15, ICES-003 Battery Battery Type Sealed, maintenance-free, valve-regulated, lead-acid UPS Configuration (20) 12V, 7.2 Ah batteries (included as standard) EBM Configuration (20) 12V, 9 Ah batteries UPS Battery Charging <2 hours to 80% usable capacity at nominal line voltage after full load discharge EBM Battery Charging No more than 15x discharge time to 90% usable capacity at nominal line voltage after full load discharge 1. Due to continuing product improvement programs, specifications are subject to change without notice.

800.322.4877 Page 6 of 7 powerware.com/avaya OPTIONS

Seismic Kit The seismic kit stabilizes the UPS in areas such as California that have earthquake safety requirements. The seismic kit holds the UPS, the PPDM, and an EBM (a total of 11U). It is equipped with casters (wheels) for easy movement and a set of brackets that can be used to bolt the kit to the floor. You can use multiple seismic kits if you have more than 1 EBM, but be sure to order a 48-inch battery extender cable.

Extended Power Distribution Modules (EPDM) EPDMs provide additional output receptacle choices. For example, PDM06 pictured above is designed with a 5-50R output receptacle for 120V DEFINITY installations.

4-post Rail Kit The UPS ships with mounting ears and handles. However, they do not completely support the UPS in a rack enclosure. If a shelf does not support the UPS, you'll need to order the optional rackmount kit. Order 1 kit per UPS and 1 kit per EBM. For example, order 3 kits for a configuration with a UPS, a PDM, and an EBM.

Alarm Relay Card The Alarm Relay Card is used to connect the UPS to a DEFINITY Remote Maintenance Board to monitor alarm contacts. It fits into the option slot on the rear panel of the UPS.

800.322.4877 Page 7 of 7 powerware.com/avaya