Check Testing Results July to December 2015

Total Page:16

File Type:pdf, Size:1020Kb

Check Testing Results July to December 2015

GEMS ACT COMPLIANCE: CHECK TESTING RESULTS JULY TO DECEMBER 2015

1. Purpose This report presents the results of check tests of models of GEMS products finalised between 1 July and 31 December 2015.

2. Background Check testing refers to activities undertaken to ensure that models of GEMS products meet the relevant determination’s GEMS level requirements, often referred to as minimum energy performance standards or MEPS; and the energy efficiency claims of manufacturers and suppliers. Check tests are conducted on behalf of the GEMS Regulator by National Association of Testing Authorities (NATA) accredited or affiliated laboratories either in Australia or overseas. Further information is available from the GEMS Check Testing Policy.

3. GEMS Products Check Tested The GEMS Regulator finalised the check tests of 41 models of the following nine GEMS products:

GEMS Product No. Models Self-ballasted compact fluorescent lamps (CFL) 10 Clothes washing machines 8 Computers 5 Incandescent lamps 5 Air conditioners 3 Computer monitors 3 External power supplies 3 Household refrigerators and freezers 2 Dishwashers 2 Total 41

4. Check Test Results Twenty-four of the 41 models (59%) met the relevant determination’s GEMS level requirements and the energy efficiency claims of manufacturers and suppliers at the completion of Stage (1) check testing. Seventeen models (41%) did not.

GEMS Product Stage 1 Pass Stage 1 Fail Self-ballasted compact fluorescent lamps (CFLs) 0 0% 10 100% Clothes washing machines 7 88% 1 12% Computers 5 100% 0 0% Incandescent lamps 0 0% 5 100% Air conditioners 2 67% 1 33% Computer monitors 3 100% 0 0% External power supplies 3 100% 0 0% Household refrigerators and freezers 2 100% 0 0% Dishwashers 2 100% 0 0% Totals 24 59% 17 41%

In accordance with the GEMS Check Testing Policy, registrants of the 17 models failing the Stage (1) check test were given the choice to arrange for Stage (2) check testing or elect to cancel the registration of the models. 1 The registrants of five models: four self-ballasted compact fluorescent lamps and one clothes washing machine chose to arrange Stage (2) check testing that subsequently found those models met the relevant requirements and claims of the manufacturers and suppliers. No further action was required.

Twenty-nine models (71%) in total therefore met the relevant GEMS level requirements and energy efficiency claims of manufacturers and suppliers at the completion of Stage (1) and Stage (2) check testing. Twelve (29%) did not. The following graph depicts the percentages for each GEMS product.

Details of the 29 models that passed Stage (1) or Stage (2) check testing are included at Attachment “A”.

5. GEMS Regulator Responses In relation to the 12 models that did not meet requirements or claims, the GEMS Regulator responded as follows:

5.1. Cancel registrations The registrants of 12 models elected to cancel their registrations. Attachment “B” details these models and the reasons for the cancellations.

6. Registration Issues A number of models of GEMS products were unregistered at the time of check testing. The GEMS Regulator worked with manufacturers and suppliers of these models to ensure GEMS registration requirements were met.

7. Monitoring and Enforcing Compliance The GEMS Regulator reminds all suppliers of GEMS products of their obligations under the GEMS Act 2012. The GEMS Regulator, assisted by GEMS inspectors, monitors compliance with the GEMS Act via a GEMS Compliance Monitoring Program of check testing and market surveillance. Further information is available at energyrating.gov.au.

Attachment A. The 29 models that passed Stage (1) or Stage (2) check testing.

GEMS Product Brand Model Number Air conditioner TCL TAC-18CHSA/BY4 Air conditioner Temperzone ISU 159KYD / OSA 159RKTH Clothes washing machine Beko WMY 8068 LB1 Clothes washing machine Fisher & Paykel WH8060P1 Clothes washing machine Panasonic NA-140VG4WAU Clothes washing machine Miele WKR770 WPS Clothes washing machine Miele WKG130 Clothes washing machine Miele WDA110 Clothes washing machine Daewoo DWD-FD1452 Clothes washing machine Samsung WA10H7200GW Computer Toshiba Satellite L50D-B Computer ACER Aspire XC-603 Computer MSI AE222 (MS-AC11) Computer ASUS EEE Book1 - X205T Computer HP 14N243TU (N243TU) Computer monitor BenQ GW2255 Computer monitor Lenovo Think Vision T2224p Computer monitor Asus VX239H Dishwasher Samsung DW-FG520W Dishwasher Smeg SA4510X1 External power supply Delta ADP-36EH C External power supply Huntkey HKA06519533-8L External power supply Shenzhen Longtenghui Electron Equipment Department ZXT137 Household refrigerator/freezer Fisher & Paykel RF522ADX4 Household refrigerator/freezer LG GN-407GSL Self-ballasted CFL E-Star ESSP25W65E27 Self-ballasted CFL Philips 14w Tri Tube warm white Self-ballasted CFL GE Lighting FLE20HLX/827/B22/T2 Self-ballasted CFL GE Lighting FLE12HLX/827/E27/T2

3

Attachment B. The 12 GEMS registrations cancelled by the GEMS Regulator

Registration GE Brand Model Registrant Cancelled Reasons MS Pro du ct NCF0159 Sel E-Star ESSP9W27E27 Sunny Australia 09/07/2015 Failed to meet: f- 8w Mini Twist warm white 6500K Lighting ball  colour ast appearance ed  minimum co lumen mp maintenance act fluo  minimum life res cen  maximum t premature lam lamp failure p rate  minimum true power factor

QCF0101 Sel Envirolux XEU48-15R80 E27 4000K Beacon Lighting 20/08/2015 Failed to meet: f- Lucci 15W Globe R80 Cool White (Wholesales) Pty Ltd ball  minimum ast switching ed withstand co mp act fluo res cen t lam p

4

Registration GE Brand Model Registrant Cancelled Reasons MS Pro du ct QCF0102 Sel Envirolux XEU48-15R80-E27 2700K Beacon Lighting 21/08/2015 Failed to meet: f- Lucci 15W Globe Warm white (Wholesales) Pty Ltd ball  minimum ast efficacy ed  minimum co lumen mp maintenance act fluo  maximum run- res up time cen t lam p

NCF0255 Sel olsent FE-IISB-18W 2700K Big W 03/08/2015 f- 18W Spiral Warm White ball ast ed co Failed to meet: mp act  colour fluo appearance res cen t lam p

NCF0262 Sel olsent 3P414-BC-40K Megaman Lighting 11/09/2015 Failed to meet: 1707 f- 14W Tri tube cool daylight 4000K Australia Pty Ltd ball  maximum ast premature ed lamp failure co rate

5

Registration GE Brand Model Registrant Cancelled Reasons MS Pro du ct mp act fluo res cen  minimum life t lam p

NCF0274 Sel olsent FE-AU-15W 2700K Big W 03/08/2015 Failed to meet: f- 15W Globe warm white  colour ball appearance ast ed  minimum co efficacy mp  minimum act lumen fluo maintenance res cen  maximum t premature lam lamp failure p rate  minimum life

NIN0010 Inc OSRAM Halogen Classic A ES OSRAM Australia 22/09/2015 Failed to meet and 64543 A ES 42W 240V B22D/BC Pty Ltd esc  lifetime ent o requi lam red 2000 p hours but MV measured halo gen 912 hours non refle 6

Registration GE Brand Model Registrant Cancelled Reasons MS Pro du ct ctor AIN0071 Inc OSRAM Halogen Classic A ECO FR OSRAM Australia 22/09/2015 Failed to meet: and 64544 A ECO FR 53W 240V frosted E27/ES Pty Ltd esc  lifetime ent o requi lam red 2000 p hours but MV measured halo gen 1996 non hours refle ctor  lumen maintenance o requi red 80% but measured 79.7%

QIN0016 Inc GE 100W 240V D0 GE Lighting Australia 12/11/2015 Failed to meet: and Halogen GLS clear B22 Ltd esc  lifetime ent o requi lam red 2000 p hours but MV measured halo gen 1100 non hours refle ctor QIN0046 Inc FOZZ HALO ecohalogen 35W Beacon Lighting 05/11/2015 Failed to meet: and GU5.3 12V 36D (Wholesales) Pty Ltd esc  lifetime ent o requi lam red 2000 p hours but 7

Registration GE Brand Model Registrant Cancelled Reasons MS Pro du ct ELV halo measured gen 552 hours refle ctor QIN0052 Inc olsent Q35 MR16/CG/36 GE Lighting Australia 14/12/2015 Failed to meet: and Halogen Reflector MR16 Ltd  lifetime esc Dimmable 12V ent o requi lam red 2000 p hours but ELV halo measured gen 912 hours refle ctor AAC1378 Air Pioneer GTIO-100A6/GTE-100A6 Pioneer International 05/11/2015 Failed to meet: con Internationa diti l  AEER at rated one capacity by r -18%  ACOP at rated capacity by -8.1%  Capacity (Cooling) by -40.3%  Capacity (Heating) by -38.3%  AEER by -41.4%  ACOP by -36.4%

8

9