Comment N Date Log CD#: o . : ICC STANDARDS - PUBLIC PROPOSAL FORM PLEASE SEE INSTRUCTIONS (SUBMITTAL RULES OF PROCEDURES). ALL SUBMITTALS MUST BE IN COMPLIANCE WITH THESE PROCEDURES. CLOSING DATE: All Proposals Must Be Received by the Announced Closing Date

1) Indicate the format in which you would like to receive your Public Proposal Report (PPR): Paper x *Download (*Note: A paper copy will not be sent to you if you have chosen to download the PPR from the ICC Web Site.) 2) PLEASE TYPE OR PRINT CLEARLY : FORMS WILL BE RETURNED if they contain unreadable information.

Name: James E. Waller, P. E. Date: July 29, 2013 Jurisdiction/Company: Remagen Safe Rooms Submitted on Behalf of: Remagen Safe Rooms Address: P. O. Box 796 City: Monteagle State: TN Zip +4: 37356-0796 Phone: 931-924-3961 Ext: Fax: 931-924-3961 eMail: [email protected]

3) *Signature: X Signature on File * I hereby grant and assign to the ICC all rights in copyright I may have in any authorship contributions in any proposal or comment I make to the ICC. I understand that I will have no rights in any ICC publications that use such contributions in the form submitted by me or another similar form and certify that such contributions are not protected by the copyright of any other person or entity. 4) Indicate appropriate ICC Standard associated with this Public Comment – Please use Acronym: IS-STM (See bottom of this form or the instructions for list of Names and Acronyms for the ICC Standards)

5) Revision to: X Section 702.1.3 Table Figure 6) COMMENT Revise as follows (check BOX and state proposed change): Revise as follows: Add new text as follows Delete and substitute as follows: X Delete without Substitution:

Show the proposed NEW or REVISED or DELETED TEXT in legislative format: Line through text to be deleted. Underline text to be added.

702.1.3 Intake openings. Outside air intake openings located in the same wall shall be located a minimum of 10 feet (3048 mm) horizontally and separated from any hazardous or noxious contaminant, such as emergency or back-up generator vents or exhaust, fuel storage tank vents and containers, maintenance or custodial storage facilities.

X COMMENT Continued (Attach additional sheets as necessary) 7) SUPPORTING INFORMATION (State purpose and reason, and provide substantiation to support proposed change):

The dimensional constraint on the location of an outside air intake opening fails to insure quality of ventilation of a tornado shelter. The minimum 10 foot horizontal spacing of intake openings on the same wall of a tornado shelter is an arbitrary restriction which cannot be proven to assure adequate or improved ventilation, cross ventilation, or air quality of intake air.

The percentage of total natural ventilation openings which must be located in the lower half of a tornado shelter (or within 46 inches of the floor) is specified in Section 702.1.1.1 Location of Ventilation Openings. The implication of this provision is that outside air intake openings for natural ventilation are to be located in walls of the tornado shelter. Section 702.1.3 Intake openings, requires a minimum horizontal spacing of outside air intake openings of 10 feet. The sizes of outside air intake openings are not restricted by Section 702. Therefore, a larger number of smaller openings or a smaller number of larger openings are permitted to be used for outside air intake openings on tornado shelter walls. Thus, flexibility in ventilation schemes is permitted and facilitated. This is particularly beneficial to tornado shelter designers who need to position outside air intake ventilation openings between structural framing members or wall reinforcement. The requirement for a minimum horizontal spacing of outside air intake openings on a single wall, while not assuring adequate ventilation, cross ventilation,

ICC Standards Public Proposal eForm Revised: August 15, 2011 or air quality of intake air, places an arbitrary, and overly restrictive, lower limit on the size of outside air intake openings on a tornado shelter wall.

SUPPORTING INFORMATION Continued (Attach additional sheets as necessary)

PLEASE USE SEPARATE FORM FOR EACH PROPOSAL SUBMITTAL AS A DOCUMENT ATTACHMENT TO AN eMAIL IS PREFERRED eMail: [email protected] Phone: (708) 799-2300 x4317 Fax: (708) 799-0320

If eMAIL is not available, mail form and disk to: International Code Council, 4051 W. Flossmoor Rd. Country Club Hills, IL 60478 Name of ICC Standard: The following acronyms should be used when designating the name of a Standard.

Acronym ICC Standard Name

IS-BLE Standard on Bleachers, Folding and Telescopic Seating, and Grandstands IS-RHW Standard for Residential Construction in High Wind Regions IS-IEDC Landscape Irrigation Sprinkler and Emitter Standard IS-LOG Standard on Design, Construction and Performance of Log Structures IS-MAN Manufactured Housing Construction & Safety Standards IS-STM Standard on Design, Construction and Performance of Storm Shelters A117.1 Standard on Accessible and Usable Buildings and Facilities