1 X GE PG6541B 56000Kw Natural Gas 13.8 Kv 60Hz Combined Cycle Power Plant

Total Page:16

File Type:pdf, Size:1020Kb

1 X GE PG6541B 56000Kw Natural Gas 13.8 Kv 60Hz Combined Cycle Power Plant

CFAS Enterprises Inc. After Market Utility Power Equipment Brokerage Mailto:[email protected] Turbine URL: http://CFASPower.com/Index.html Reciprocating URL: http://CFASPower.com/Recips.html

GTG_1670RC_FmPG6541CC_60Hz.doc

1 x GE PG6541B 56000Kw Natural Gas 13.8 Kv 60Hz Combined Cycle Power Plant

Asking Price: US$7.35 MM

Plant Performance Ambient Temperature: 48 Deg F Fuel: Natural Gas Gross Output: 58,500Kw Plant Heat Rate: 8,900 Btu/Kwh

Gas Turbine Generator Set

Gas Turbine Manufacturer: General Electric Year Manufactured: 1992 Model Number: PG6541B Type: Continuous Packaged By: GE Packager Model Number: 6A1PB148-1 Rating: Base/Peak 42400 Kw Inlet Temperature: 48 Deg F Speed: 5,100 Rpm

Gear Reducer Manufacturer: Westech Rating: 68000 Hp Speed: 5100/3600 Rpm

Generator Manufacturer: General Electric Type: Tewac Rating: 46,500 Kva Voltage: 13800 V, 3phase, 60 Hz Speed: 3600 Rpm Pf: 0.9 Armature Amps: 1845 Amps Insulation Class: F/F (Stator/Rotor)

Controls: Mark IV Speedtronic Black Start: Diesel Engine Fuel: Natural Gas

Nox Control: Steam Injected Year Built 1992 Shutdown: Still Connected Total Life Time Hours: 46,200 Hours Since Last Major Overhaul 2007: 1000 Hours

HRSG Manufacturer: Zurn Type: Dual Pressure

Steam Flow HP Super Heated Steam: 900 Psig/900 Deg F, 147,726 Lbs/Hr LP Saturated Steam: 185 Psig/384 EF F, 24,623 Lbs/Hr

Steam Turbine Generator Manufacturer: GE Rating: 16,500 Kw Pressure Temperature Flow: 900 Psig Inlet Steam: 900 Deg F 132,000 Lbs/Hr Controlled Steam: 180 Psig 0 To 80,000 Lbs/Hr Exhaust Steam: 2" HGA 137,400 Lbs/Hr Rating With Zero Extraction: 16,500 Kw Steam Rate: 8.00 Lbs/Kwh Speed: 5362 Rpm Inlet Steam Size: 10" AE Steam Size: 8" Uncontrolled Steam Size: 6" Exhaust Steam: 75"

Governor: Woodward 505E

Generator Generator Manufacturer: GE Rating 18,333 Kva Voltage: 13800 V, 3 Phase, 60 Hz Pf: 0.9 Speed: 1800 Rpm Armature Amps: 767 Amps Exciter: Brushless, PMG Type: Tewac

Condenser Square Ft: 16,619 Sq Ft Condenser Water Flow: 15,947 GPM Cooling Water Inlet Temp.: 75 Deg F Cooling Water Outlet Temp.: 92 Deg F

History Of Steam Turbine Generator Steam Turbine Generator Was Installed In 1990 Approximately 50,000 Hours Water Treatment System Power House Building w/Ton & 20 Ton Cranes 115 Kv Substation 13.8 Kv Switchgear 4160 V Motor Starters 480 V MCC Battery And Battery Charger UPS Plant History: Start Up 1992 And Operated Until 1998, After This Date The Plant Ran As Peak Standby Only

Recommended publications