Firmware, Aastra 7444Ip, R1S
Total Page:16
File Type:pdf, Size:1020Kb
Public PRODUCT REVISION INFORMATION
1 (2)
Prepared (also subject responsible if other) No.
R&D MX-ONE Jie Cao
109 21-CAA 158 0070-14 Uen Approved Checked Date Rev Reference
R&D MX-ONE (Ulf Södermark)
2014-09-29
A
Firmware, Aastra 7444ip, R1S
1 Reason for revision
This version of the application firmware shall be used in DBC 444 01 (Aastra 7444ip).
New function:
Possible to disable dial out from MNS key(s) by command (see commands in command Help)
setMNSKeyNoDial
setMNSKeyRangeNoDial
unsetMNSKeyNoDial
unsetMNSKeyRangeNoDial
It can be centrally stored (using configure tag [StoreUserData])
Configure Ring level in Handsfree mode via setting HandsfreeRingLevel (under [RingLevel]) to SILENCE, or NORMAL. Default value is NORMAL.
Usability improvements for 802.1X.
Fault correction:
LDCBR00085254 (CSTA1: CC-agent can’t answer incoming ringing call)
LDCBR00086515 (All Dialog 42x02 have unreadable characters on the web interface using Russian language) Public PRODUCT REVISION INFORMATION
1 (2)
Prepared (also subject responsible if other) No.
R&D MX-ONE Jie Cao
109 21-CAA 158 0070-14 Uen Approved Checked Date Rev Reference
R&D MX-ONE (Ulf Södermark)
2014-09-29
A
LDCBR00086575 (A-number not shown on ip phone)
LDCBR00086856 (DBC444 freezing 12 seconds if Shortcuts key is used to return from alerting MNS)
LDCBR00087088 – (IP phone 7444 MNSBusyRingLevel=LOW does not work in Handsfree mode)
Big 509X certificates for 802.1x TLS will cause 802.1X authentication failure.
RTP is not disabled as it should be which may cause double tones.
2 Technical solution.
Replace the current application file with:
Unit Product number From To
Application CAA 158 0070 R1N R1S
3 Other products concerned
Configuration file CAA158 0058 R3U (common with the DBC44601 telephone). Burn-in file CAA158 0073 R1S
4 Reference
ECO301146 Public PRODUCT REVISION INFORMATION
1 (2)
Prepared (also subject responsible if other) No.
R&D MX-ONE Jie Cao
109 21-CAA 158 0070-14 Uen Approved Checked Date Rev Reference
R&D MX-ONE (Ulf Södermark)
2014-09-29
A
5 Recommended measures
The new configuration file R3U contains new parameter values. At upgrading the recommendation is to use the new configuration file and adapt it with all site dependent parameter values.
This revision of the firmware is to be introduced in new manufacturing.