TTS420 PriMON Euro ISDN Primary Rate Monitor

USER'S GUIDE

TS420 PriMON 1 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

HARRIS CORPORATION has a policy of continuous product improvement, and therefore the specification of this product may be subject to change. Whilst every effort has been made to ensure the accuracy of this User's Guide at the time of printing, Hosiden Besson Limited will not be liable for any errors.

If you find any errors in this User's Guide or would like to make suggestions for improvement please send your comments by email to: [email protected]

The content of this User's Guide is proprietary and neither the whole nor any part thereof may be used, copied or reproduced in any form without the prior permission of HARRIS CORPORATION

HARRIS CORPORATION 809 Calle Plano, Camarillo, CA93012 USA Tel: +1 805 389 2135 Fax: +1 805 389 2101 TS420 PriMON 2 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

Contents

The TS420 PriMON...... 5 Introduction to TS420 PriMON...... 5 TS420 PriMON Applications...... 7 High Impedance Bridged...... 7 Attenuated Monitor Points...... 8 Operation...... 9 Control buttons...... 10 PSU jack socket...... 10 BNC sockets...... 10 Impedance Switch...... 11 Serial Port...... 11 Layer 1 LED indicators...... 12 TERMINAL Layer 1 Activated...... 12 NETWORK Layer 1 Activated...... 12 Layer 1 Alarms...... 12 Layer 2 LED indicators...... 14 Layer 3 LED indicators...... 14 TS420 PriMON with Windows Terminal or HyperTerminal...... 17 Connecting TS420 PriMON to a PC...... 17 Setting TS420 PriMON parameters...... 19 Real Time Simple Protocol Decode States...... 21 Layer 1...... 22 Layer 2...... 22 Layer 3...... 23 Typical Simple Protocol Decode Trace...... 25 TS420 PriMON 3 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor Power-Down...... 26 Battery Condition...... 26 TS420 PriMON with Genius...... 27

TS420 PriMON 4 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor The TS420 PriMON The TS420 PriMON Euro ISDN Primary Rate Monitor package has the following contents:

 The TS420 PriMON  4 AA alkaline batteries two fitted and two spares  4.5v dc mains plug top PSU  9 way D male to 9 way D female straight through PC serial cable  Two BNC to BNC cables  This User's Guide  Accessory pouch

Introduction to TS420 PriMON The TS420 PriMON is for use by installation and maintenance technicians to monitor a Euro ISDN primary rate interface to verify that the terminal equipment to network protocol is functioning correctly at Layer 1, 2 and 3.

Used in stand-alone mode it is simple and intuitive to use and provides a quick verification tool for installers.

TS420 PriMON 5 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor Used in conjunction with Genius PC protocol analysis software, TS420 PriMON is an extremely powerful maintenance analysis tool. When used with Genius, TS420 PriMON parameters such as the serial port setup, date and time are automatically set to the PC settings on connection or when invoking the Genius application.

This User's Guide describes the TS420 PriMON used as a stand-alone maintenance tool or connected to a PC running Windows Terminal, HyperTerminal or any other terminal emulation programme. Genius is described in a separate User's Guide.

TS420 PriMON can be bridged in high impedance mode onto a Network - Terminal connection or connected to 75 ohm attenuated monitor points on access network equipment.

TS420 PriMON is powered by two AA batteries, which give up to 20 hours continuous operation. Alternatively, a plug top mains PSU can be used which provides regulated output of 4.5Vdc, 100mA dc minimum fitted with a 2.5mm dc plug. Note that the mains PSU MUST BE REGULATED. DO NOT USE BATTERY CHARGERS.

TS420 PriMON 6 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor TS420 PriMON Applications

2Mbit/s Upstream

2Mbit/s Downstream

ISPBX Multiplexer Exchange NT A

Terminal Network

ISPBX Tx/Rx Monitor point HI Z bridge High Impedance Bridged The TS420 PriMON may be connected within a cable section typically between the ISDN primary rate equipment and the Network Terminating point (NT). For coaxial cables the coax must have a T connector inserted into each signal path onto which the TS420 PriMON Terminal and Network BNCs are connected.

TS420 PriMON 7 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

Attenuated Monitor Points Multiplexers, switching equipment and repeaters typically have attenuated monitor points.

TS420 PriMON can be directly connected to these monitor points by BNC leads or an adapter cable if the equipment has a connector other than BNC.

The receiver on both the Terminal and Network connections has an AGC circuit which will adapt to a signal from 0dB to -30dB relative to the transmit signal power from the ISDN terminal or network equipment.

TS420 PriMON 8 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

Operation BNC sockets 9 way D female PC serial port

Impedance slider switch

PSU jack socket

TS420 PriMON 9 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

Control buttons I/O Press and hold > 1 second to switch on Press and hold > 1 second to switch off

History: Short press to show latched Layer1 previous alarms History LED flashes red when in History mode Short press to go back to real time alarms

Reset: Short press to reset the alarm, error History latches and Layer 3 call progress LEDs When switching ON press Reset and then I/O to reset stored parameters of serial port data rate and alarm expiry.

PSU jack socket Connect the low voltage plug of a suitable plug top mains unit (Regulated 4.5Vdc 100mA min, 2.5mm dc plug) if the TS420 PriMON is to be left on for an extended period of time. (Note: battery life approx 20 hours)

BNC sockets Nominal input signal HDB3 2.37v peak Input signal range: 0 to -30dB flat loss

TERMINAL Connect the ISDN terminal transmit side

TS420 PriMON 10 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor Note: The TS420 PriMON designates decode from this input as Usr.

NETWORK Connect the ISDN NT network transmit side. Note: TheTS420 PriMON designates decode from this input as Net

Impedance Switch Set switch to 75 when connecting to Monitor points

Set switch to Hi Z when bridging Connect to coax using a BNC T adapter inserted into the signal line

Serial Port The PC serial port is a female 9 way D connector.

Pin out: 1 not connected 2 TS420 PriMON transmit data 3 TS420 PriMON receive data 4 not connected 5 signal ground 6 DTR (TS420 PriMON output) 7 RTS (TS420 PriMON input) 8 DTR (TS420 PriMON output)

TS420 PriMON 11 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor 9 not connected

Baud rate: 19200 (default), 38400, 57600,115200 Data bits: 8 Parity: none Stop bits: 1 Flow control: Xon/Xoff or hardware

Layer 1 LED indicators TERMINAL Layer 1 Activated This LED flashes green when a valid G.704 2Mbit/s frame is detected from the transmit output of the ISDN terminal equipment.

NETWORK Layer 1 Activated This LED flashes green when a valid G.704 2Mbit/s frame is detected from the transmit output of the NT network side equipment.

Layer 1 Alarms There are four signal alarm indicators for each of the Terminal and Network signal directions.

TS420 PriMON 12 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

Loss of Signal LOS No valid signal detected for 15 consecutive bit periods. If a loss of signal condition occurs the receiving equipment should return an RAI Remote alarm Indication signal

Alarm Indication Signal AIS all 1s upstream- the transmitting equipment has detected a downstream local alarm condition

The AIS signal is transmitted upstream when the transmitting equipment has lost frame alignment or lost signal on its incoming upstream signal and vice versa.

Loss of Frame Alignment LFA TS420 PriMON has lost G.704 frame alignment

Local loss of frame alignment indicates a fault with the transmitting equipment or connection.

Remote Alarm Indication2Mbit/s Upstream RAI the transmitting equipment has detected a local alarm condition 2Mbit/s Downstream

A multiplexer will return the RAI signal if it has detected a local alarmISPBX condition (e.g. LOS, LFA) on itsMultiplexer incoming receivedExchange signal. LFA or A LOS AIS NT RAI

Terminal Network TS420 PriMON 13 04/25/18 ISPBX Tx/Rx HI Z bridge Monitor point 75 ohm TTS420 PriMON Euro ISDN Primary Rate Monitor

Layer 2 LED indicators A Layer 2 Activated LED indicates if a Layer 2 data link is established for each of the Terminal and Network signal directions. When a Layer 2 connection is established the Layer 2 Activated LED flashes green. If a Layer 2 data link fails or is not present then the LED is OFF.

Layer 3 LED indicators There are 6 Layer 3 message indicator LEDS for each of the Terminal and Network signal directions. These LEDS decode Layer 3 message types for a particular call (the

TS420 PriMON 14 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor same call reference value). Upon decoding the message type the condition is latched and the LED flashes green until the RESET button is pressed.

The purpose of the Layer 3 LEDS is to give a quick visual indication that the Layer 3 call setup and clear down sequence is functioning correctly.

This feature is useful if the TS420 PriMON is being used in stand alone mode during equipment commissioning, or to give a quick health check on the PRI access link.

A typical message sequence for a call established by the Terminal side, answered at the destination called party and cleared by the Terminal side would be indicated as shown below.

TS420 PriMON 15 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

LED states for a typical call setup and clear

TS420 PriMON 16 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

TS420 PriMON with Windows Terminal or HyperTerminal TS420 PriMON can operate in a basic protocol decode mode with a PC running a terminal emulation program such as Windows Terminal or HyperTerminal.

In this mode a simple time and date stamped protocol decode trace can be viewed in real time and stored on the PC using the terminal emulation program.

The TS420 PriMON has 128kbytes of SRAM FIFO buffer memory, which will store the protocol trace if the data rate exceeds the serial port rate temporarily, if the serial port is not connected, or the PC interrupts the data flow.

Connecting TS420 PriMON to a PC To connect the TS420 PriMON to a PC running a terminal emulation program, carry out the following steps:

1. Connect the 9 way D cable to the TS420 PriMON and an available COM port on the PC using an adapter at the PC if necessary.

2. Invoke the terminal emulation program on the PC (e.g. HyperTerminal)

TS420 PriMON 17 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

3. Set the selected COM port parameters from within the terminal program to: baud rate: 19200; data bits: 8; stop bits: 1 parity: none; flows control: Xon/Xoff

4. Connect the TS420 PriMON onto the PRI network 5. Switch the TS420 PriMON ON by holding down RESET and pressing I/O together for > 1 second. This will set the default baud rate of 19200.

[Note that when using the Genius protocol analysis software, the Genius software will automatically set the TS420 PriMON parameters negotiating the fastest baud rate and synchronizing the date and time to the PC clock.]

6. The following text header should appear in the PC terminal window

TS420 PriMON 18 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

*********************************************** * TS420 PriMON - Primary Rate ISDN Monitor. * * HARRIS CORPORATION (V 1.00) * * Last used 02/03/00 13:05:06 * * Power On 02/03/00 16:34:50 * ***********************************************

Setting TS420 PriMON parameters When the Esc key on the PC keyboard is pressed, parameter setup options are displayed in the terminal window as shown below:

***************************************** Data Rate: (0) 19,200 * (1) 38,400 (2) 57,600 (3) 115,200

Alarm Expiry: (6) 10 Mins * (7) 30 Mins (8) Always On (9) Off

Date: (y) 02/03/00 Time: (z) 16:35:02.894

Battery voltage = 2.95 Press letter to select parameter

TS420 PriMON 19 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor Enter = return to decode. *****************************************

Whilst in the parameter setup mode, the TS420 PriMON flashes its LEDs sequentially in four blocks to warn that the unit is in setup mode.

The above table shows the default settings. The current setting is designated by the * character.

To restore the default values, switch on the TS420 PriMON whilst holding down the TS420 PriMON RESET key.

To set a new data rate press the appropriate key e.g. to set 115,200 press the 3 key and the new rate is designated with * indicating the current setting. To change the data rate, the PC COM port data rate must be set to match the new TS420 PriMON setting.

The major alarm sounder can be set to expire after 10 minutes (the default), 30 minutes, to be always on or always off by similarly pressing the appropriate key. For example to disable the alarm press 9.

The date and time should need to be set only once since they are non-volatile parameters and are not affected when setting the default values. All parameters will be

TS420 PriMON 20 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor retained if the AA cells are flat or removed for replacement.

To set the date press y on the PC keyboard and enter the day, month and year in a two digit format:

The battery voltage condition is displayed to assist the user in estimating the battery condition.

After setting the desired parameters, press Enter or  (return) to return to real time protocol decode.

Real Time Simple Protocol Decode States Upon switching on the TS420 PriMON it will immediately go into real time protocol decode mode.

This displays Layer 1 condition, Layer 2 frame type and Layer 3 message type events. All protocol decode events are time and date stamped to an accuracy of 1 Ms.

TS420 PriMON 21 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

Layer 1 The following Layer 1 conditions are prefixed with date and time stamp and Usr indicating they are sent from the Terminal and present on the Terminal BNC, or Net indicating they are sent from the Network and present on the Network BNC terminal.

Decode Description LOS Loss of signal AIS All 1s alarm received LFA Loss of frame alignment RAI ON Remote alarm indication signal start RAI OFF Remote alarm indication signal stop L1 Activated G704 framed synchronisation achieved

Layer 2 The following frame types are prefixed with a date and time stamp and Usr indicating they are sent from the Terminal and present on the Terminal BNC, or Net indicating they are sent from the Network and present on the Network BNC terminal.

Decode Description RR receive ready TS420 PriMON 22 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor RNR receive not ready REJ reject SABME set asynchronous balanced mode extended

DM disconnected mode UI unnumbered information DISC disconnect UA unnumbered acknowledgement FRMR frame reject L2 ERROR unrecognised frame

Layer 3 The following messages are prefixed with a date and time stamp and Usr indicating they are sent from the Terminal and present on the Terminal BNC, or Net indicating they are sent from the Network and present on the Network BNC terminal.

INFORMATION ALERTING CALL_PROC CONNECT CONNECT_ACK PROGRESS SETUP

TS420 PriMON 23 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor SETUP_ACK USER_INFO DISCONNECT RELEASE

RELEASE_COMP CONGESTION_CTRL FACILITY NOTIFY STATUS STATUS_ENQ RESUME RESUME_ACK RESUME_REJ SUSPEND SUSPEND_ACK SUSPEND_REJ SEGMENT RESTART RESTART_ACK L3 Message Error unrecognised message

TS420 PriMON 24 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor

Typical Simple Protocol Decode Trace ****************************************** * TS420 PriMON Primary Rate ISDN Monitor* * HARRIS CORPORATION (V 1.00) * * Last used 06/03/00 12:57:50 * * Power On 06/03/00 12:58:05 * ******************************************

06/03/00 12:58:05.017 Usr LOS 06/03/00 12:58:05.018 Net LOS 06/03/00 12:58:27.010 Net L1 Activated 06/03/00 12:58:27.011 Net RAI ON 06/03/00 12:58:30.110 Net RAI OFF 06/03/00 12:58:30.111 Usr L1 Activated 06/03/00 12:58:30.326 Net SABME 06/03/00 12:58:30.346 Usr UA 06/03/00 12:58:34.030 Net SETUP 06/03/00 12:58:34.057 Usr ALERTING 06/03/00 12:58:34.431 Net RR 06/03/00 12:58:36.005 Usr CONNECT 06/03/00 12:58:36.021 Net CONNECT_ACK 06/03/00 12:58:36.290 Usr RR 06/03/00 12:58:39.612 Net DISCONNECT 06/03/00 12:58:39.765 Usr RR 06/03/00 12:58:39.774 Usr RELEASE TS420 PriMON 25 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor 06/03/00 12:58:39.792 Net RELEASE_COMP 06/03/00 12:58:40.022 Usr RR 06/03/00 12:58:49.751 Usr RR

In the above sequence the initial condition is that both Network and User/Terminal side are OFF. The Network side establishes Layer 1 followed by the Terminal side. The Network side then sets up the Layer 2 data link and sends a call SETUP message. The User/Terminal side then CONNECTS and the call DISCONNECT is made from the Network side.

Power-Down On power-down the following message is sent… Power off dd/mm/yy hh:mm:ss

Battery Condition If, during operation, the condition of the internal batteries drops below 1.8 Volts, the following message is sent approximately every ten seconds…

Warning, low battery x.xxV. Where x.xx is the battery voltage.

If the voltage drops below 1.7 Volts, then the following message will be sent, and the unit will turn off.

Battery dead x.xxV. TS420 PriMON 26 04/25/18 TTS420 PriMON Euro ISDN Primary Rate Monitor Where x.xx is the battery voltage.

TS420 PriMON with Genius TS420 PriMON operates with the Genius advanced protocol analysis software running on a PC.

In this mode the TS420 PriMON is connected to the PC with the 9way D serial cable as for the Terminal emulation mode. The User must setup the correct COM port from within Genius. Genius automatically sets TS420 PriMON to the fastest baud rate available and synchronizes the TS420 PriMON date and time to the PC clock. The User does not need to specifically set these parameters as is required in Terminal emulation mode.

When operating with Genius, the Genius protocol decode is stored on the PC in real time for later post processing analysis.

For operation of the Genius software please refer to the separate Genius User's Guide.