DIVISION 8 – DOORS AND WINDOWS

SECTION 08 80 00 – GLAZING Page 1 of 5

PART 1 - GENERAL

1.01 RELATED DOCUMENTS

1. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply to work of this section.

1.02 DESCRIPTION OF WORK

1. "Glass includes prime glass, processed glass, and fabricated glass products. "Glazing" includes glass installation and materials used to install glass. Types of work in this section include glass and glazing for: .1 Windows, door glass and borrowed lights. .2 Glass specification includes both field and factory installed products.

1.03 QUALITY ASSURANCE

1. Prime Glass Standard: FS DD-G-451.

2. Heat-Treated Glass Standard: FS DD-G-1430.

3. Safety Glass Standard: CPSC 16 CFR 1201.

1.04 SUBMITTALS

1. Provide two (2) samples, 12" square, of each glass product, except for clear single-pane units.

1.05 JOB CONDITIONS

1. Meet with Glazier and other trades affected by glass installation, prior to beginning of installation. Do not perform work under adverse weather or job conditions. Install liquid sealants when temperatures are within lower or middle third of temperature range recommended by manufacturer.

PART 2 - PRODUCTS

R- /10-11 DIVISION 8 – DOORS AND WINDOWS

SECTION 08 80 00 – GLAZING Page 2 of 5

2.01 GLASS PRODUCTS

1. Type A: 1/4" laminated glass conforming to CPSC Rule 1201.

2. Type B: 1/4" square pattern wire reinforced glass with U.L. Fire Rating and meeting CPSC Rule 1201.

2.02 GLAZING SEALANTS AND COMPONENTS

1. Provide color of exposed sealant/compound indicated or if not otherwise indicated, as selected by Architect from manufacturer's standard colors, or black if no color is so selected. Comply with manufacturer's recommendations for selection of hardness, depending upon the location of each application, conditions at time of installation, and performance requirements as indicated. Select materials, and variations or modifications, carefully for compatibility with surfaces contacted in the installation.

2. 1-Part Silicone Rubber Glazing Sealant: Elastomeric silicone sealant complying with FS TT-S-00l543, Class A, non-sag. Provide acid type recommended by manufacturer where only non-porous bond surfaces are contacted; provide non acid type recommended by manufacturer where one or more porous bond surfaces are contacted.

2.03 GLAZING GASKETS

1. Molded Neoprene Glazing Gaskets: Molded or extruded neoprene gaskets of the profile and hardness required for watertight construction; comply with ASTM D 2000 designation 2BC 4l5 to 3BC 620, black.

2.04 MISCELLANEOUS GLAZING MATERIAL

1. Cleaners, Primers and Sealers: Type recommended by sealant or gasket manufacturer.

2. Setting Blocks: Neoprene or EPDM, 70-90 durometer hardness, with proven compatibility with sealants used.

R- /10-11 DIVISION 8 – DOORS AND WINDOWS

SECTION 08 80 00 – GLAZING Page 3 of 5

3. Spacers: Neoprene or EPDM, 40-50 durometer hardness with proven compatibility with sealants used.

4. Compressible Filler (Rod): Closed-cell or waterproof-jacketed rod stock of synthetic rubber or plastic foam, proven to be compatible with sealants used, flexible and resilient, with 5-l0 psi compression strength for 25% deflection.

PART 3 - EXECUTION

3.0l STANDARDS AND PERFORMANCE

1. Watertight and airtight installation of each glass product is required, except as otherwise shown. Each installation must withstand normal temperature changes, wind loading, impact loading (for operating sash and doors), without failure including loss or breakage of glass, failure of sealants or gaskets to remain watertight and airtight, deterioration of glazing materials and other defects in the work.

2. Protect glass from edge damage during handling and installation, and subsequent operation of glazed components of the work. During installation, discard units with significant edge damage or other imperfections.

3. Glazing channel dimensions as shown are intended to provide for necessary bite on glass, minimum edge clearance, and adequate sealant thicknesses, with reasonable tolerances. Adjust as required by job conditions at time of installation.

4. Comply with combined recommendations and technical reports by manufacturers of glass and glazing products as used in each glazing channel, and with recommendations of Flat Glass Marketing Association "Glazing Manual," except where more stringent requirements are indicated.

5. Install insulating glass units to comply with recommendations by sealed Insulating Glass Manufacturers Association, except as otherwise specifically indicated or recommended by glass and sealant manufacturers.

R- /10-11 DIVISION 8 – DOORS AND WINDOWS

SECTION 08 80 00 – GLAZING Page 4 of 5

3.02 PREPARATION FOR GLAZING

1. Clean glazing channel and other framing members to receive glass, immediately before glazing. Remove coatings which are not firmly bonded to substrate. Remove lacquer from metal surfaces where elastomeric sealants are used.

2. Apply primer or sealant to joint surfaces where recommended by sealant manufacturer.

3.03 GLAZING

1. Install setting blocks of proper size in sill rabbet, located 1/4 of glass width from each corner. Set blocks in thin course of heel-bead compound, if any.

2. Provide spacers inside and out, of proper size and spacing, for glass sizes larger than 50 united inches, except where gaskets or pre- shimmed tapes are used for glazing. Provide 1/8" minimum bite of spacers on glass and use thickness equal to sealant width, except with sealant tape use thickness slightly less than final compressed thickness of tape.

3. Set units of glass in each series with uniformity of pattern, draw, bow and similar characteristics.

4. Voids and Filler Rods: Prevent exudation of sealant or compound by forming voids or installing filler rods in channel at heel of jambs and head (do not leave voids in sill channels), except as otherwise indicated and depending on light size, thickness and type of glass, and complying with manufacturer's recommendations.

5. Force sealants into channel to eliminate voids and to ensure complete "wetting" or bond of sealant to glass and channel surfaces.

6. Tool exposed surfaces of glazing liquids and compounds to provide a substantial "wash" away from glass. Install pressurized tapes and gaskets to protrude slightly out of channel, so as to eliminate dirt and moisture pockets.

R- /10-11 DIVISION 8 – DOORS AND WINDOWS

SECTION 08 80 00 – GLAZING Page 5 of 5

7. Clean and trim excess glazing materials from glass and stops or frames promptly after installation, and eliminate stains and discolorations.

8. Gasket Glazing: Miter cut and bond ends together at corners where gaskets are used for channel glazing, so that gaskets will not pull away from corners and result in voids or leaks in glazing system.

3.04 CURE, PROTECTION AND CLEANING

1. Protect exterior glass from breakage immediately upon installation, by use of crossed streamers attached to framing and held away from glass. Do not apply markers to surfaces of glass. Remove non- permanent labels and clean surfaces. Cure sealants for high early strength and durability.

2. Remove and replace glass which is broken, chipped, cracked, abraded or damaged in other ways during construction period, including natural causes, accidents and vandalism.

3. Wash and polish glass on both faces not more than 4 days prior to date scheduled for inspections intended to establish date of substantial completion in each area of project. Comply with glass product manufacturer's recommendations for final cleaning.

END OF SECTION

R- /10-11