CMI Extira Addendum to Guide Specification

Total Page:16

File Type:pdf, Size:1020Kb

CMI Extira Addendum to Guide Specification

May 2014

Addendum to Product Guide Specification for Finished Products Using JELD-WEN, inc. Extira as a Component

ECTION XX XX XX

This document should be used by the manufacturer that will be incorporating JELD-WEN, inc. Extira exterior treated wood composite panels into a component of a finished product.

This document includes the text that should be added to the guide specification in Construction Specifications Institute (CSI) Format prepared by the manufacture of the finished product. The guide specification should be written according to the CSI 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described in The CSI Construction Specifications Practice Guide.

Address all questions and comments regarding this document and JELD-WEN, inc. Extira composite panels to:

JELD-WEN, inc., 825 Shiner Road, P.O. Box 311, Towanda, PA 18848. Toll Free 800-255- 0785. Website www.extira.com. E-mail [email protected].

Specifier Notes: Extira panels are a green product.

Sustainable Materials: No old growth wood is used in the manufacture of Extira panels. They are made from wood that is of no commercial timber value and is the byproduct of other operations. This leftover wood is also detrimental to the overall vitality of the forest. All wood comes from an area within a 200-mile radius of the Towanda, PA production facility. The facility uses 100% northern hardwoods, which includes maple, beech, oak, and other species. Extira panels are treated with zinc borate, an EPA-registered biocide and a naturally occurring earth chemical that is environmentally safe and ensures protection against termites.

No Added Urea Formaldehyde: Extira has no added urea formaldehyde. This is certified by Scientific Certification Systems under certificate number SCS-NAUF-01802. Through repeated testing by the Composite Panel Association (CPA), Extira has demonstrated formaldehyde emissions equivalent to background levels found in the environment.

Complies with CARB: Extira panels are acknowledged by the California Air Resources Board’s (CARB) Airborne Toxic Control Measure (ATCM) 93120 to utilize exempt status ultra-low emitting formaldehyde (ULEF) resins.

PART 1 GENERAL

Addendum to Product Guide Spec for Finished Products Using JELD-WEN, inc. Extira as a Component XX XX XX - 1 1.1 REFERENCE STANDARDS

Specifier Notes: Include the following three reference standards in the Reference Standards Article of the guide specification of the finished product.

1.1.A. ASTM D 1037 – Standard Test Methods for Evaluating Properties of Wood-Base Fiber and Particle Panel Materials.

1.1.B. AWPA E7 – Standard Method of Evaluating Wood Preservatives by Field Tests with Stakes.

1.1.C. AWPA E16 – Field Test for Evaluation of Wood Preservatives to be Used Out of Ground Contact: Horizontal Lap-Joint Method.

1.2 SUBMITTALS

Specifier Notes: Include the following paragraph in the Submittals Article of the guide specification of the finished product. Edit as necessary.

1.2.A. Submittals for Exterior Treated Wood Composite Panels: 1.2.A.1. Manufacturer’s Certification: Submit manufacturer’s certification that composite panels comply with specified requirements and are suitable for intended application.

1.3 DELIVERY, STORAGE, AND HANDLING

Specifier Notes: Include the following paragraph in the Delivery, Storage, and Handling Article of the guide specification of the finished product. Edit as necessary.

1.3.A. Storage and Handling Requirements of Exterior Treated Wood Composite Panels: 1.3.A.1. Store composite panels under cover, protected from weather, off ground, and on flat surface. 1.3.A.2. Keep composite panels dry.

PART 2 PRODUCTS

2.1 MATERIALS

Specifier Notes: Include the following paragraph in the Materials Article of the guide specification of the finished product. Edit as necessary.

2.1.A. Exterior Treated Wood Composite Panels: JELD-WEN, inc. “Extira”. 2.1.A.1. Description: Exterior-grade, treated wood composite panels for non- structural applications. 2.1.A.2. Material: 2.1.A.2.a. Wood fibers combined with phenolic resins, zinc borate, and water repellent. 2.1.A.2.b. No added urea formaldehyde. 2.1.A.3. Surface: Sanded 2 sides (S2S), smooth, unprimed.

Addendum to Product Guide Spec for Finished Products Using JELD-WEN, inc. Extira as a Component XX XX XX - 2 2.1.A.4. Substrate: 2.1.A.4.a. 1-piece solid substrate, uniform density, not laminated. 2.1.A.4.b. No knots or voids.

Specifier Notes: Specify thickness of the composite panels.

2.1.A.5. Thickness: [1/2 inch] [5/8 inch] [3/4 inch] [1 inch] [1-1/4 inches] [Indicated on the Drawings]. 2.1.A.5.a. Tolerance: Plus or minus 0.005 inch. 2.1.A.6. Typical Properties, 3/4-Inch Thickness: 2.1.A.6.a. Density, ASTM D 1037: 47 pcf (0.753 g/cm3). 2.1.A.6.b. Modulus of Rupture, ASTM D 1037: 3,187 psi (22.0 N/mm2). 2.1.A.6.c. Modulus of Elasticity, ASTM D 1037: 280 kpsi (1,958 N/mm2). 2.1.A.6.d. Internal Bond, ASTM D 1037: 103 psi (0.71 N/mm2). 2.1.A.6.e. Direct Screw Withdrawal, ASTM D 1037: 2.1.A.6.e.1) Face: 374 lbs (1663 N). 2.1.A.6.e.2) Edge: 324 lbs (1441 N). 2.1.A.6.f.24-Hour Soak, ASTM D 1037: 2.1.A.6.f.1) Thickness Swell: 2.6 percent. 2.1.A.6.g. Accelerated Aging Test, 6-Cycle, ASTM D 1037: Retained 90 percent of original strength. 2.1.A.6.h. Termite Resistance, AWPA E7 Rating Scale, 3-Year Exposure: 7.9 out of 10. 2.1.A.6.i. Rot Resistance, AWPA E16, 3-Year Exposure: 1.0 out of 5.

Specifier Notes: Consult JELD-WEN, inc. for information regarding the adhesives tested with Extira panels. The information can also be found on the Extira website: http://www.extira.com/wp-content/uploads/Tech-Bulletin_Using-Extira-General.pdf. The end user of Extira panels should contact the adhesive manufacturer for information on suitable adhesives for the specific application.

2.1.A.7. Adhesives: Designed for use on wood composite materials. 2.1.A.8. Paint: 2.1.A.8.a. Primer: 2.1.A.8.a.1) High-quality, exterior, oil or alkyd solvent-based or acrylic- latex primer system. 2.1.A.8.a.2) Designed for application over composite wood substrates. 2.1.A.8.b. Top Coat: 2.1.A.8.b.1) High-quality, exterior-grade paint system. 2.1.A.8.b.2) Compatible with primer system. 2.1.A.8.b.3) Do not use shake and shingle paints, vinyl acrylic paint, vinyl acetate co-polymer paint, vinyl acetate paint, clear coatings, flat oil paint, transparent or semi-transparent stains, or opaque solvent stains.

PART 3 EXECUTION

Addendum to Product Guide Spec for Finished Products Using JELD-WEN, inc. Extira as a Component XX XX XX - 3 3.1 INSTALLATION

Specifier Notes: Include the following paragraph in the Installation Article of the guide specification of the finished product. Edit as necessary.

3.1.A. Installation of Exterior Treated Wood Composite Panels: 3.1.A.1. Cut, miter, and rout composite panels in accordance with manufacturer's instructions. 3.1.A.2. Ensure composite panels are dry before installing or finishing. 3.1.A.3. Finish: 3.1.A.3.a. Apply primer and top coat to composite panels in accordance with paint manufacturer's instructions. 3.1.A.3.b. Apply primer and top coat before exposing composite panels to exterior applications. 3.1.A.3.c. Ease 90-degree edges, where possible, to improve paint coverage. 3.1.A.4. Fasten composite panels with adhesives, nails, and screws in accordance with manufacturer's instructions. 3.1.A.5. Use adhesives in accordance with adhesive manufacturer's instructions. 3.1.A.6. Position nails no closer than 1/2 inch from edges. 3.1.A.7. Do not install nails into edges. 3.1.A.8. Drill pilot holes when installing screws into edges.

END OF SECTION