Technical Information General Information:

Address: Leeming Street, Mansfield, NG18 1NG

Proprietors: Mansfield District Council

Seating: 534

Accessibility: All areas (with the exception of the Balcony seating area and Stage Fly Tower galleries) are wheelchair accessible. Induction loops are fitted in the Box Office and Auditorium.

Spaces: Main Auditorium, Dance Studio, Rehearsal Room, Meeting Place and Lounge are all available for hire. Enquiries should be made to Management or Administration.

Contacts:

Management: Andrew Tucker [email protected] 01623 412950

Administration: Elaine Wharmby [email protected] 01623 412951

Technical: Dai Evans [email protected] 01623 412952

Marketing: Louise Atkin [email protected] 01623 412920

Education: Chris Neil [email protected] 01623 41292

Box Office: Ian Grindle [email protected] 01623 633133 Stage:

A PDF plan is available on our website. Please visit www.mansfield.gov.uk/palacetheatre/technical.asp. Please contact the Technical Manager or Administrator for the password.

Hard copies of 1:25 or 1:100 Scale plans can be provided on request.

Load in: At the rear of building with flat access directly on to the stage. Please note we do not supply ramps. Vehicles may remain at the dock for the duration of the production. Due to the nature of the access to the Dock door from the nearby streets it is advisable for visiting productions with large vehicles to contact the theatre prior to arrival so that suitable arrangements can be made to assist drivers.

Stage floor: 12mm Ply on hardboard sheets. Fixing/screwing into the floor, within reason, is possible with the prior agreement of the Technical Manager except on the Stage apron. Flat floor.

Proscenium: 8.5 metres wide by 5.26 metres high.

Depth: 8.3 metres from Setting line (rear edge of Safety Curtain) 10.55 metres from front edge of apron.

Wings: Stage left – 6 metres from proscenium to wall, full depth of stage.

Stage right – 5 metres from proscenium to wall, no wing upstage of 6.5 metres from Setting line

Flying: 27 Single Purchase Counterweight sets each at 500kg SWL UD. There are spaces in the system – see Stage Plan for details.

Bar length: 14 metres (sets 1 – 25) 10.5 metres (sets 28 – 39) offset to Stage Left

Grid height: 14.71 metres Max Bar out dead: 13.90 metres Max Bar in dead: 1.45 metres

Drapes: 4 x Black Wool serge border 14 x 2 metres 1 x Black Wool serge border 10.5 x 2 metres 10 x Black Wool serge legs 7 x 2 metres 6 x Black Wool serge legs 7 x 3 metres 1 x Pair of full Black tabs with ties and hooks 1 x Pair of full Gold tabs with ties and hooks 1 x White Cyclorama 10 x 9 metres 2 x White Gauze 10 x 7 metres 1 x Black Gauze 10 x 7 Metres

House tabs – permanently hung on Bar 2 1 x Fibre Optic Star cloth

Risers: 6no. 2m x 1m x 0.5m units 4no. 2m x 1m Ambideck (6” and 12” legs available)

Access: 1 x Tallescope Zarges ladders Various step ladders

Pit: The Stage Apron can be lowered as a single unit to provide an orchestra pit. This can be set at any level down to a depth of 2.8 metres. At the lowest level an area of approximately 10 metres x 3 metres is available.

Stage Management:

The Stage Management desk is located Down Stage Left with integrated Cue light control, Comms and TV monitor with low light camera on the Balcony front.

Front of House and Back Stage call system is operated from the SM desk. Wireless comms x 4 available on request.

Wired comms at Lighting, Sound, Fly floor, SR, USR, USC, Orchestra pit and Follow spots.

Washing machine and drier are available.

10 x Dressing Rooms – 3 at stage level, 6 under stage and 1 at 1st floor level. Capacity varies but most rooms can accommodate up to 6 persons at a squeeze.

Lighting:

Control: ETC Ion with 2 x 20 Fader wing located at rear of stalls

Zero 88 Linebacker

Dimmers: 120 x Zero88 Chilli Pro24 each at 2.5kw

Circuits: Auditorium – 36 ways Stage level – 26 ways Fly floor (SL) – 58 ways

9 x 15a Independent circuits at various locations

2 x 18 way IWB 1 x 12 way IWB 2 x 6 way IWB

Power: 32a Lighting ring main around the stage with 13a RCD Outlets DSL, DSR, USR and USC

125a 3 phase on Ceeform located USC. 125a to 63a Jumper available.

Separate 13a supply at Control position.

DMX: Single DMX 512 line from Control position through dimmers. DMX outs at various locations in auditorium and around the stage. 1 x 8 way Pulsar DMX splitter 1 x 5 way Swisson DMX splitter

Lanterns: 8 x Alto F 2kw Fresnel 4 x Quartet 650w Fresnel 28 x Strand 1kw Fresnel 10 x Strand Cantata 18/32 profile 36 x ETC Source 4 profile. A selection of 19 – 50 degree lenses are available. 40 x Par 64, (10 x Short nose). 21 x Strand Coda 1kw flood 20 x CCT 500w flood 12 x Par 56 LED lights 6 x Chauvet Colorado 72 LED Batten 9 x Chauvet ColourDash Par Quad 18 RGBA 4 x Chauvet Colorado 2 Quad Zoom Tour 4 x Chauvet Rogue 2 Spot 4 x Martin MAC 250 Entour 4 x GLP Volkslicht 60 RGB Zoom LED wash light 2 x Robert Juliat Topaze followspot 4 x UV Cannon 1 x Showtec Titan Strobe 9 x Chroma Q Scroller

Effects: Neutron Haze machine Jem Magnum Pro 650 Smoke machine Jem Magnum Pro 2000 Smoke machine 1 x 6 way Le Maitre Pyro control 2 x 2 way Le Maitre Pyro control Various Le Maitre pyro pods

Standard Lighting Rig Plan available on request.

Sound:

Control: Allen and Heath GLD 80 2 x AB1608 Stage Box 1 x AR0804 Expander CAT 5 network (Can also be used for AV and LX)

Main PA: 2 x d & b Audiotechnik 602 2 x d & b Audiotechnik 902 2 x d & b Audiotechnik E3

Infill/Delay: 10 x JBL Control 10

Monitors: 2 x d & b Audiotechnik MON15 2 x JBL JRX112M 1 x LD Systems powered speaker Behringer 4 way Headphone Amplifier x 2

Play Back: Tascam MD350 Minidisc Sony JE460 MD Player Denon DN630 CD Player Tascam CD 200i (with iPod dock) (Above sub mixed through an ART MX821S 8 channel rack mount mixer). M Audio M Track 8 USB interface

Effects: Yamaha Rev 100, Alessis Midiverb TC Electronics M One Dual Effects Processor 2 x 2 Channel Drawmer Compressor/Limiter

EQ: 1 x Behringer Ultradrive Speaker Management system for Main PA 1 x Behringer Ultra Curve 2 x Behringer FBQ 3102 1 x XTA GQ600

Mics: 12 x Sennheiser G3 512 Radio Systems c/w 12 x Body pack transmitters 1 x Sennheiser SKM 500 935 Hand Held radio micro- phone to be used with one of the G3 512 receivers

Various other microphones including SM58, SM57, PCC 160, AKG 91, AKG 93, Sennheiser e602, C1000.

We have a good selection of mic stands available.

We have 12 x lit “Rat” Music Stands.

Piano: Yamaha C3 Baby Grand Piano

Power: 63a Single Phase Ceeform at USR 32a Sound ring main on stage 13a Sockets at Control position at rear of Stalls.

All sound power is isolated from Stage Lighting and building supplies.

Miscellaneous:

Charges may be applicable for the use of certain items of equipment, provision of staff or services.

A full list of current charges can be obtained by contacting Andrew Tucker, Dai Evans or Elaine Wharmby from the contact details above.

The availability of any item of equipment listed above should not be assumed. Please check with the Technical Manager prior to arrival.

Correct at 23.9.2016

D Evans Technical Manager