FAQ for the Portable Air Conditioner(ENMD Type)

Total Page:16

File Type:pdf, Size:1020Kb

FAQ for the Portable Air Conditioner(ENMD Type)

FAQ for the Portable Air Conditioner 1

FAQ for the Portable Air Conditioner(ENMD Type)

Contents

What is a SEER rating?...... 2

How to choose…………………………………………………………………………………2

1. Self diagnosis function...... 3

2. What is maximum length and height for installation of air exhaust pipe ...... 2

3. Why is water leaked when the unit is travelled...... 3

4. Installation…………………………………………………………………….……………4

5. Trouble shooting...... 8

1 FAQ for the Portable Air Conditioner 2

How to choose the Portable Air Conditioners

It is just for reference to choose the EnStar’s Portable Air Conditioner.

ENMD 10,000 ENMD 12,000 (10,000Btu/H) (12,000Btu/H)

SQUARE FEET 160 – 270 270 – 440 (WEST EXPOSURE) SQUARE FEET 250 – 300 300 – 500 (EAST EXPOSURE) SQUARE FEET 210 – 330 330 – 550 (SOUTH EXPOSURE) SQUARE FEET 270 – 420 420 – 700 (NORTH EXPOSURE)

We recommend increasing the Btu/Hr of this calculation for  Frequently used kitchen (4000 Btu/Hr)  Height than 8 feet (1000 Btu/Hr)

Warning: The Portable Air Conditioner should be put upright. If the Portable Air Conditioner be laid down for a while, it needs to put upright at least four (4) hours before operating

Q: What is a SEER rating? A: Seasonal Energy Efficiency Rating is a governmental environmental standard for the air conditioning industry.

Q: Why are some units SEER 10.2 and others SEER 13? A: The government recently made a minor increase in the SEER rating to 13. Because there were a lot of SEER 10.2 already manufactured, they ruled that only units manufactured after that date would have to be SEER 13 and that is why you will still see some of each.

2 FAQ for the Portable Air Conditioner 3

1. [PAC] Self diagnosis function.

LCD or LED display Malfunction Remedy P2 Water full protection. Press the TURBO button on LCD to drain the water P1 Drainage protection. Press the TURBO button on LCD to drain the water E3 T3 sensor malfunction. Turn off the unit and restart it 10 E2 T2 sensor malfunction. minutes later, if it happens same, E1 T1 sensor malfunction. call the service center. T1: Temperature of ambient. T2: Temperature of evaporator. T3: Temperature of condenser.

2. [PAC] What is maximum length and height for installation of air exhaust pipe?

The length of the air exhaust must be between 50 cm ~ 200 cm and the height of the end of air exhaust must be between 40 cm ~ 130 cm from the ground level.

If the air exhaust requires bend, bend as shown as below

3 FAQ for the Portable Air Conditioner 4

3. [PAC] Why is water leaked when the unit is travelled?

The unit hold some water inside it for cooling down the hot Freon gas when the unit is operating. Therefore when the unit need to be travelled, you need to keep the unit uprightly and drain out this water from the unit too .

4.Installation

Installation of the Portable Air Conditioner

Warning: The Portable Air Conditioner should be put upright. If the Portable Air Conditioner be laid down for a while, it needs to put upright at least four (4) hours before operating.

Location Put the Portable Air Conditioner(PAC) at an open place where the air outlets cannot be covered up, place the unit no less than 50cm away from a wall or other obstacle.

4 FAQ for the Portable Air Conditioner 5

Power Supply Before connecting the PAC to the power supply, please check: 1) The power supply is rated voltage ±6%. 2) The power supply line is properly earthed and sized for a pickup current of 20A, so as to avoid voltage drops when starting the PAC 3) The unit connected to a 16Amp socket by a 16Amp plug fitted. 4) Cross-section area of the wires must be at least 2.5㎟. 5) If the power supply cord of the unit is broken, please replace it with a special power supply cord and a skilled service man is needed to do this. 6) Please go to the maintenance department for changing the power cord and plug it they are damaged. 7) The PAC must be positioned so that the plug is touchable. 8) The minimum clearance from the PAC to combustible surface is 50㎝.

For to prevent flicker impressions during the start of the compressor (technical process) following installation conditions do apply.

1) The power connection for the PAC has to be done at the main power distribution. This distribution has to be of low impedance. Normally the required impedance is reached at a 32A fusing point. 2) No other equipment has to be connected to this power line. 3) For detailed installation acceptance please refer to your contract with the power supplier, if restrictions do apply for products like washing machines, air conditioners, or electrical ovens. 4) For power details of the PAC refer to the rating plate of the product.

Preparation work First of all, prepare the exhaust hose as the below picture show to you.

Second, connect the exhaust hose with unit, like the blow picture.

After this two steps, please make sure the exhaust hose’s connect is OK 5 FAQ for the Portable Air Conditioner 6

Air Exhaust duct 1) Fix the square end of the exhaust duct to the exhaust terminal of the unit. 2) Put the other end (discharge) to the nearest window with the window kit.

Note: those pictures are just example

6 FAQ for the Portable Air Conditioner 7

The length of the air exhaust must be between 50㎝ ~ 200㎝.

3) When mounting the air exhaust, try to keep it horizontal.

4) If mounting in the wall, the height of the hole should be 40㎝ ~ 130㎝.

5) If the air exhaust requires bend, bend as shown as below.

Permanent installation

Attach one end of the duct to the exhaust air outlet of the mobile air conditioner. According to the arrow direction, push it downwards, be sure to fix thoroughly. Install the adaptor A onto the wall by using 4 expansion plugs and screws, be sure to fix thoroughly. 7 FAQ for the Portable Air Conditioner 8

Attach the other end of the duct to adaptor A. Cover the hole using the adaptor cap when not in use.

5. [PAC] Troubleshooting

PROBLEM POSSIBLE CAUSE REMEDY Check the power supplier if the power supplier is supplied Power failure to the unit. Check the power cord and correct if No power display damaged. on panel or any Transformer (Discharge Check resistance between the two input/output lines on one of the transformer before transformer. Replace the transformer if either of the buttons failure. testing) input/output is open or the transformer is damaged. Display board or main Check the voltage on display board. Replace the display Remote control PCB failure board if it is +5V else replace the main PCB. failure. Check the voltage of battery. Replace batteries if the Battery failure voltage is lower than 2.3V. Check voltage. Call an electrician if not within limits. Test capacitor. Fan motor runs Replace if not within +/-10% of manufacture's rating. Cycles on overload. intermittently Check bearings. Replace the motor if the blower wheel cannot rotate freely. Pay attention to any change from high speed to low speed. Replace the motor if the speed does not change. The amount of the refrigerant is too much, making the Compressor Refrigerant compressor load too big. Recycle and recharge the stops instantly refrigerant after checking for the reason. after startup. The compressor is blocked inside. Replace after checking Compressor for the reason. No power Check voltage at electrical outlet. Correct if none. Water alarm Check and correct if water alarm happens. Check voltage at the power cord terminal on Main PCB. Power supply cord Replace the power cord if none. Transformer (Discharge Check resistance between the two input/output lines on transformer before transformer. Replace the transformer if either of the testing) input/output is open or the transformer is damaged. Fan motor will not Wire disconnected or Connect wire. Refer to wiring diagram for terminal run. connection loose identification. Repair or replace loose terminal. Select fan speed and Check the voltage on main PCB. Main PCB failure Replace the main PCB if no voltage in anyone. Test capacitor. Capacitor (Discharge Replace if not within +/-10% of manufacture's rating. capacitor before testing) Replace if shorted, open or damaged. Fan blower hitting scroll. Realign assembly. Will not rotate Check fan motor bearings. Replace the motor if motor shaft do not rotate.

8 FAQ for the Portable Air Conditioner 9

Replace the fan blower if cracked, out of balance, or Fan blower partially missing.

Fan motor noise. Loose screws Tighten them. Replace the motor if knocking sounds continue when Worn bearings running or loose, or the motor hums or noise appears to be internal while running. Voltage Check voltage. Call Supply Authority if not within limits. Check the wire connections, if loose, repair or replace the terminal. If wires are off, refer to wiring diagram for Wiring identification, and replace. Check wire locations. If not per wiring diagram, correct. Check voltage of main PCB. Replace the main PCB if Main PCB failure Compressor will open. not run while Check the capacitor. Capacitor (Discharge fan motor runs. Replace if not within +/-10% of manufacturers rating. capacitor before testing) Replace if shorted, open, or damaged. Check the temperature setting if not at the coolest (in Room temp sensor cooling mode) or the warmest (in heating mode). Set it if not. Check the compressor for open circuit or ground. If open Compressor or grounded, replace the compressor. Remove the cabinet and carefully rearrange tubing not to Excessive noise. Copper tubing contact cabinet, compressor, shroud and barrier. Water tank full Check and pour if the water tank is full. Water depth sensor if Check and replace if failure. failure Water pump failure Check and replace if the pump if failure. Water full alarm Water depth is over load Check and drainage the water in the chassis by open the in chassis drainage hose on the chassis. Water depth sensing Check and replace or realign if the structure is failure. structure Air filter Clean or replace if restricted. Realign and assemble if the installation of the air Air discharge pipe discharging pipe failure. Replace if damaged. Determine if the unit is properly sized for the area to be Unit undersized cooled or heated. Condenser and Clean or replace if restricted. Evaporator Check the structure of water showering system and clean Water shower failure if blocked. Check the fan capacitor and replace if not within +/-10% Fan motor of manufactures rating. Cooling or Clean or remove if any barrier is found to block the heating feels Air flow inlet/outlet wind flow of the unit. not good Check the tubes for reasons of leakage. Recycle the Less refrigerant refrigerant, correct the leakage points and recharge. Regulate the flow if capillary tube and make the Capillary tube evaporating temperature appropriate if the evaporator is frosted. Replace if blocked. Repair joint if leaking. The inlet and outlet valve of the compressor is damaged, making the low pressure connected with the high Compressor pressure. The refrigerating system can not produce high pressure and low pressure. Replace the compressor9 after checking for the reason. Heat sources Reduce if too many. FAQ for the Portable Air Conditioner 10

No power Check the voltage. Call an electrician if no within the limit. Wiring Check the terminals. Repair and correct if loose. Temperature setting Check and adjust the temperature setting. Mode setting Check and adjust the mode setting. No cooling or Check and replace if the compressor, the over-load Compressor heating. protector or wiring is broken. Electric heater failure Check and replace if the heater is damaged. Over heat fuse failure Check and replace if the fuse is damaged. Check the voltage of main PCB. Replace the main PCB Main PCB when the unit failure in heating mode. The input power supply voltage is too low. Call an Power supply electrician if not within limits. The unit starts Check and replace the main PCB if the compressor relay and stops Main PCB on PCB is shorted or damaged. frequently. When the room temperature is too high, the compressor Room temperature will protect.