3123A AQURON® 1000 CURING & CONCRETE TREATMENT

1. GENERAL

This section relates to AQURON® Concrete Treatments to form an internal hydrogel within the concrete providing curing, surface hardening, anti-dusting, sheen enhancement for new concrete floors that will be left "EXPOSED" as the final finish.

1.1 RELATED WORK Refer to ~ for ~

Documents

1.2 DOCUMENTS Refer to the general section 1233 REFERENCED DOCUMENTS. The following documents are specifically referred to in this section: ASTM C309 Standard specification for Liquid Membrane-Forming Compounds for Curing Concrete

1.3 MANUFACTURER/SUPPLIER DOCUMENTS Manufacturer's and supplier's documents relating to this part of the work: AQURON® products MSD sheets AQURON® products technical data

Manufacturer/supplier contact details Company: Markham Global

Email: [email protected] NZ: 0800 693 694 (++646 8422248) www.markhamglobal.com AUSTRALIA 1800 693 694 (++6174153 6286) www.markhamglobal.com.au

Warranties

1.4 WARRANTIES Warrant this work under normal environmental and use conditions against failure. Warranty period is subject to confirmation of project and due compliance by related trades where applicable.

Refer to the general section 1237 WARRANTIES for details of when completed warranties must be submitted.

Requirements

1.5 QUALIFICATIONS Application to be carried out by an AQURON® approved applicator strictly in accordance with manufacturer's recommendations. For approved applicators contact:

Markham Global. Refer to MANUFACTURER/SUPPLIER DOCUMENTS for contact details.

1.6 NO SUBSTITUTIONS Substitutions are not permitted to any specified AQURON® products or associated components.

2. PRODUCTS

Materials

201310 – Web Version – AQURON 1000 for New Concrete 3123A Page 1 2.1 CURING AND CONCRETE TREATMENT AQURON®1000™curing and concrete treatment complies to moisture retention requirements of ASTM C309, a deep penetrating, non toxic waterborne solution which forms an insoluble calcium silicate gel within the concrete matrix. Tested to have nil crystalline silica.

3. EXECUTION

Conditions

3.1 TECHNIQUE DISCUSSION Before application, arrange a meeting to confirm the application timing and procedure.

Application

3.2 AQURON® 1000™ CURING AND CONCRETE TREATMENT Once power trowelling has been completed to produce a dense, burnished finish, apply AQURON®1000™, spray applied to the surface. Leave AQURON®1000™ between 7- 28 days to cure before commencing diamond grinding and honing techniques.

3.3

4. SELECTIONS For further details on selections go to www.aquron.co.nz or www.aquron.com.au Substitutions are not permitted to the following, unless stated otherwise.

4.1 CURING AND CONCRETE TREATMENT Location: ~ Product: AQURON®1000™

201310 – Web Version – AQURON 1000 for New Concrete 3123A Page 2