DIVISION 28 23 23 conformal coating applied to the printed circuit FV40D4SFP SERIES – FIBER OPTIC board. TRANSMITTER AND RECEIVER 1.08 WARRANTY ENGINEERING SPECIFICATIONS A. Standard Communication Networks Comprehensive Lifetime Warranty: Comnet PART 1 - GENERAL warrants the product to be free of factory defects 1.01 SUMMARY under manufacture’s Lifetime Warranty as A. Fiber Optic 10-Bit Digital Four-Channel Video submitted under article 1.05 (E) Transmitter and Receiver with Four Bi- PART 2 - PRODUCTS directional Data Channels 2.01 MANUFACTURER 1.02 SECTION INCLUDES A. Acceptable Manufacturer: Communication A. FV40D4SFP Series 10-Bit Digital Four-Channel Networks, Inc.; 3 Corporate Drive, Danbury, CT Video with four Bi-directional data channels – 06810 USA; Telephone: 203-796-5300; Fax 203- Standalone and Rack Mount 796-5303; Email: [email protected] 1.03 REFERENCES Internet: www.ComNet.net A. Underwriters Laboratory (UL) B. Substitutions: Not Permitted B. Underwriters Laboratory Canada (ULC) C. All fiber optic modules shall be supplied from a C. European Union Compliance (CE) single manufacturer. 1.04 SYSTEM DESCRIPTION 2.02 MANUFACTURED UNITS A. Performance Requirements: Provide a 10-bit A. Model Number Descriptions: Reference Table digital Video Transmitter /Receiver and A: Product Number Descriptions integrated data transmitter system that transmits B. Model Compatibility Chart: Reference Table B: four channels of one-way video and four Product Compatibility Chart channels of bi-directional data. 2.03 GENERAL SPECIFICATIONS 1. The system shall utilize SFP-based optics A. The 10-bit digital four-channel video and four- capable of simultaneous video and data channel bi-directional data transmitter and transmission on one optical fiber. receiver system shall be a Comnet 1.05 SUBMITTALS FVT/FVR40D4SFP series module. The module A. Product Data: Manufacturer’s printed product shall be capable of transmitting four full color data sheet for each type of Transmitter/Receiver video signals in real time in NTSC, PAL or specified. SECAM formats. The module shall support the B. Detail Drawings: Electrical and optical connect transmission of four channels of RS-232, RS- drawings. Product mounting template. 422, and 2-wire and 4-wire RS-485 data. The C. Manufacturer’s Installation and Operating module shall be transparent to data protocols Manual: Printed installation and operating used by various manufactures, providing for information for each type of universal compatibility should future system Transmitter/Receiver specified. expansion or changes be required. The module D. Test Reports: Manufacturer’s Printed Test shall require no in-field electrical or optical Report via a Tektronics VM700A Video Test adjustments or in-line attenuators to ease Generator verifying product performance meets installation. The module shall utilize SFP-based or exceeds the specified product performance optics to allow for flexibility of fiber type, fiber referenced in Part 2. connector type, and optical path length. The E. Warranty: Manufacturer’s Printed Warranty module shall provide data transmit, video input 1.06 DELIVERY, STORAGE AND HANDLING status indicating LED’s for monitoring proper A. Deliver materials in unopened factory packaging system operation. The modules shall provide with Manufacturer’s bar coding to the job site. automatic re-settable solid-state current limiters B. Inspect product upon delivery to assure that and independent voltage regulators on each specified products have been received. module to reduce the chance of a single point C. Store in original packaging in a climate failure of the system. The module shall be hot controlled environment. Storage Temperature swappable in a rack mount system to reduce not to exceed: -40˚ C to +85˚ C complete system shut down during maintenance 1.07 PROJECT/SITE CONDITIONS or repair. The module shall have an MTBF of A. Temperature Requirements: Products shall >100,000 hours and operate in an environment of operate in an environment with an ambient –40˚ C to +75˚ C and relative humidity between temperature range of –40˚ C to +75˚ C without 0% to 95% (non-condensing). The module shall the assistance of fan-forced cooling. be UL and ULC listed and CE marked. The B. Humidity Requirements: Products shall operate circuit board shall be UL 94 flame rated and in an environment with relative humidity of 0% meet all PCI standards. All PC boards shall be to 95% (non-condensing). If product is installed designated with part number, PC board number in condensation conditions, unit shall have Project name/project number/date 00000 - 1 Section Title (Optional information, e.g., owner, A/E) and show appropriate revision number. Housing (sometimes called “box”) shall be identical in shall be of all metal construction. All LED every respect, both electrically and physically, indicators and both electrical and mechanical with the “rack” products so that only a single connections shall be identified with silk-screened product may be used interchangeably for both labels. The module shall have a lifetime warranty the “stand alone” and “rack” applications. All to reduce system life cycle cost in an event of a ComFit products shall be supplied with a plug-in module failure. module power supply, electrical connectors, and 2.04 VIDEO SPECIFICATIONS mechanical parts to enable it to be used in “stand A. Input Video: 1 volt pk-pk (75 ohms) alone” or “rack” configuration. All ComFit B. Bandwidth: 5 Hz – 6.5 MHz products shall mount directly to a wall without C. Differential Gain: < 2 %. the need for special mounting brackets. D. Differential Phase: < 0.7 °. 2.11 ENVIRONMENTAL SPECIFICATIONS E. Tilt: <1% A. MTBF: >100,000 Hours F. Signal/Noise Ratio: 67dB @ max attenuation B. Operating Temp: –40˚ C to +75˚ C 2.05 DATA SPECIFICATIONS C. Storage Temp: -40˚ C to +85˚ C A. Data Interface: EIA RS-232, RS-422, RS-485 (2- D. Relative Humidity: 0% to 95% (non- wire and 4-wire) condensing). If product is installed under B. Data Encoding: Unit shall be transparent to data condensation conditions, unit shall have encoding (i.e. NRZ, NRZI, Manchester, Bi- conformal coating applied to the printed circuit phase) board. (Add –C to model number for conformal C. Data Rate: DC-250 kbps (NRZ) coated printed circuit board) 2.06 OPTICAL SPECIFICATIONS 2.12 REGULATORY AGENCIES/APPROVALS A. SFP-dependant AND LISTINGS 1. Optical Fiber: 62.5/125 µm or singlemode, A. Underwriters Laboratory (UL) Listing Number: SFP-dependant I.T.E. 6D16 2. Number of Fibers Required: 1 or 2, SFP- B. Underwriters Laboratory Canada (ULC) Listing dependant Number: I.T.E. 6D16 3. Optical Wavelength: SFP-dependant C. UL 94-flame rated PCB board: 94VO 4. Optical Attenuation: No manual adjustments D. required 2.13 ACCESSORIES 2.08 CONNECTORS A. Card Cage: Comnet Model Number C1 (EIA 19” A. Optical: SC or LC, SFP-dependant card cage) shall be available to house and power B. Power: Screw Clamp Terminal Strip rack mount modules. C. Data: RJ-45 receptacles B. Blank Panels: Comnet Model Number C1-BP D. Video: BNC (Gold Plated Center-PIN) shall be available to cover unused rack slots. 2.09 ELECTRICAL SPECIFICATIONS PART 3 - EXECUTION A. Power: 8-15 VDC 3.01 EXAMINATION B. Current Protection: Automatic re-settable solid- A. Inspect modules before installation. state current limiters B. Modules shall be free of any cosmetic defects or C. Voltage Regulation: Solid-state, Independent on damage. each board C. All optical connectors shall be covered with dust D. Circuit Board: UL 94 flame rated and meets all caps and remain on the module until installing PCI standards. cable connectors to module. E. Rack mount Card: Shall be hot-swappable with D. Shipping box shall include the module, power Comnet Model Number C1 (EIA 19” card cage) supply and operations manual. 2.10 MECHANICAL SPECIFICATIONS 3.02 PREPARATION A. Surface Mount Dimensions: 6.1” x 5.3” x 2.2” A. Standalone Module (Surface Mount) (15.5 cm x 13.5 cm x 5.6 cm) 1. Shall be mounted on a properly prepared B. Rack Mount Dimensions: 6.1” x 5.3” x 2.2” surface adequate for the size and weight of (15.5 cm x 13.5 cm x 5.6 cm) module. The placement of the unit shall C. Number of Rack Slots: 3 allow provision for cable installation and D. Finish: Module shall be constructed of a metal maintenance as indicated on the approved enclosure with a powder coat finish model detail drawings and in compliance with the Number F63B12 with all connections and Comnet mounting template and installation indicators silk-screened directly on unit. Rack manual. mount units shall be constructed of anodized B. Rack Mount Module (19” Rack) aluminum. 1. Shall be installed in the Comnet Model E. Weight: <2.0 lbs./1.0kg Number C1 card cage. Ensure the card cage F. This product shall conform to ComFit is installed in a standard EIA 19” (482.6 Technology. That is, all “stand alone” products mm) rack or wall standoff bracket adequate Project name/project number/date 00000 - 2 Section Title (Optional information, e.g., owner, A/E) for the size and weight of the card cage. The A. General: Locate fiber optic modules as indicated placement of the unit shall allow provision on the approved detail drawings and install for cable installation and maintenance as module in compliance with the Comnet indicated on the approved detail drawings installation and operations manual. and in compliance with the Comnet 3.04 TESTING installation manual. A. Testing the Fiber Optic Video Link. C. Optical Fibers 1. Verify that the coax and optic fibers are 1. Caution: NEVER look into the end of an properly connected. active optical fiber when using laser light 2. Make sure that power is applied to all fiber output. Eye damage can occur. Wear eye optic modules, camera, and video monitor or protection when cleaving, terminating, and other equipment used in the system. splicing fiber. 3. The AGC (automatic gain control) indicator 2. The number and type (multimode or single- LED should be lit confirming a presence of mode) of optical fiber shall meet the a video signal. requirements of the Comnet model number 4. Successful video link operation should be in article 2.06 used in the installation. visible at this point as witnessed by a good 3. All optical fiber cables shall be properly quality video picture on the monitor. installed and terminated with the mating B. Testing the Fiber Optic Data Link. optical connectors as submitted in article 1. Verify that the data leads and optical fibers 2.08 (A). are properly connected. 4. The optical link shall be tested with either a 2. Make sure that power is applied to all fiber power meter, at a minimum, or OTDR to optic modules, controllers, and receiver ensure the link budget (overall path loss) drivers or other equipment used in the plus an added 3dB of optical safety margin system. does not exceed the optical power budget as 3. Successful data link operation should be submitted in article 2.06. confirmed at this point by using the 5. All optical connectors on cable shall be controller to pan, tilt, and zoom the camera cleaned in compliance to optical connector or communicate with other equipment. manufactures specifications and covered 3.05 CLEANING with dust caps until connection to the fiber A. Follow all instructions for proper use of solvents optic module. and adhesives used for termination and splicing. 3.03 INSTALLATION B. At completion of the installation, dispose of all fiber scraps properly.

Project name/project number/date 00000 - 3 Section Title (Optional information, e.g., owner, A/E) MANUFACTURED UNITS REFERENCE TABLES

Table A: Product Number Descriptions

FVT40D4SFP SERIES DESCRIPTION FVT40D4SFP 4-channel 10-bit digital video transmitter/4-channel data transceiver, SFP-based

FVR40D4SFP SERIES DESCRIPTION FVR40D4SFP 4-channel 10-bit digital video transmitter/4-channel data transceiver, SFP-based

Table B: Product Compatibility Chart

TRANSMITTER COMPATIBLE RECEIVER FVT40D4SFP FVR40D4SFP

Table C: SFP Compatibility Chart

COMPATIBLE FIBER FIBER OPTICAL MAXIMUM SFP MODULES TYPE COUNT RECEPTACLE RANGE SFP-6 singlemode 2 LC 15 km SFP-7 singlemode 2 LC 40 km SFP-8 singlemode 2 LC 70 km SFP-9 singlemode 2 LC 120 km SFP-12 singlemode 1 LC 20 km SFP-13 singlemode 1 LC 20 km SFP-14 singlemode 1 SC 20 km SFP-15 singlemode 1 SC 20 km SFP-16 multimode 2 LC 550 m SFP-17 singlemode 1 LC 60 km SFP-18 singlemode 1 LC 60 km SFP-21 singlemode 1 SC 60 km SFP-22 singlemode 1 SC 60 km

END OF SECTION

Project name/project number/date 00000 - 4 Section Title (Optional information, e.g., owner, A/E)