DIVISION 28 13 19 A. Standard International Fiber Systems D2315 SERIES – FIBER OPTIC TRANSCEIVER Comprehensive Lifetime Warranty: IFS warrants ENGINEERING SPECIFICATIONS the product to be free of factory defects under manufacture’s Lifetime Warranty as submitted PART 1 - GENERAL under article 1.05 (E) 1.1 SUMMARY PART 2 - PRODUCTS A. Fiber Optic Data Transceiver 2.1 MANUFACTURER 1.2 SECTION INCLUDES A. Acceptable Manufacturer: International Fiber A. D2315 Series Data Transceiver – Standalone Systems, Inc.; 16 Commerce Road, Newtown, B. D2315-R3 Series Data Transceiver - Rack CT 06470 USA; Telephone: 203-426-1180; Fax 203-426-3326; Email: [email protected] m ; Internet: Mount 1.3 REFERENCES w w w. i fs. c om A. Underwriters Laboratory (UL) B. Substitutions: Not Permitted B. Underwriters Laboratory Canada (ULC) C. All fiber optic modules shall be supplied from a C. European Union Compliance (CE) single manufacturer. 1.4 SYSTEM DESCRIPTION 2.2 MANUFACTURED UNITS A. Performance Requirements: Provide a Data A. Model Number Descriptions: Reference Table Transceiver system that transmits and receives 4- A: Product Number Descriptions wire RS-485. B. Model Compatibility Chart: Reference Table B: 1. The system shall utilize 850nm optics Product Compatibility Chart capable 4-wire RS-485 data transmission on 2.3 GENERAL SPECIFICATIONS four multimode optical fibers. (D2315) A. The data transceiver system shall be an IFS 2. The system shall utilize 1300nm optics D2315 series module. The module shall support capable 4-wire RS-485 data transmission on the transmission 4-wire RS-485 data. The module four multimode optical fibers. (D2315-1300) shall be transparent to data protocols used by 3. The system shall utilize 1300nm optics various manufactures, providing for universal capable 4-wire RS-485 data transmission on compatibility should future system expansion or four single mode optical fibers. (D2315-SM) changes be required. The module shall require no 1.5 SUBMITTALS in-field electrical or optical adjustments or in-line A. Product Data: Manufacturer’s printed product attenuators to ease installation. The module shall data sheet for each type of Transmitter/Receiver provide power and data transmit and data receive specified. status indicating LED’s for monitoring proper B. Detail Drawings: Electrical and optical connect system operation. The modules shall provide drawings. Product mounting template. automatic re-settable solid-state current limiters C. Manufacturer’s Installation and Operating and independent voltage regulators on each Manual: Printed installation and operating module to reduce the chance of a single point information for each type of failure of the system. The module shall be hot Transmitter/Receiver specified. swappable in a rack mount system to reduce D. Warranty: Manufacturer’s Printed Warranty complete system shut down during maintenance 1.6 DELIVERY, STORAGE AND HANDLING or repair. The module shall have an MTBF of A. Deliver materials in unopened factory packaging >100,000 hours and operate in an environment of with Manufacturer’s bar coding to the job site. –40˚ C to B. Inspect product upon delivery to assure that +74˚ C and relative humidity between 0% to specified products have been received. 95% (non-condensing). The module shall be UL C. Store in original packaging in a climate and ULC listed and CE marked. The circuit controlled environment. Storage Temperature board shall be UL 94 flame rated and meet all not to exceed: -40˚ C to +85˚ C PCI standards. All PC boards shall be designated 1.7 PROJECT/SITE CONDITIONS with part number, PC board number and show A. Temperature Requirements: Products shall appropriate revision number. Housing shall be of operate in an environment with an ambient all metal construction. All LED indicators and temperature range of –40˚ C to +74˚ C without both electrical and mechanical connections shall the assistance of fan-forced cooling. be identified with silk-screened labels. The B. Humidity Requirements: Products shall operate module shall have a lifetime warranty to reduce in an environment with relative humidity of 0% system life cycle cost in an event of a module to 95% (non-condensing). If product is installed failure. in condensation conditions, unit shall have 2.4 DATA SPECIFICATIONS A. Data Interface: EIA RS-485 (4-wire) conformal coating applied to the printed circuit board. B. Data Encoding: Unit shall be transparent to data 1.8 WARRANTY encoding C. Data Rate: DC-400 kbps D. Operation Mode: Simplex or Full Duplex C. Number of Rack Slots: 1 2.5 OPTICAL SPECIFICATIONS D. Finish: Module shall be constructed of a metal A. IFS Model Number D2315 enclosure with a powder coat finish model 1. Optical Fiber: 62.5/125 micron multimode Number F63B12 with all connections and 2. Number of Fibers Required: 4 indicators silk-screened directly on unit. Rack 3. Optical Wavelength: 850nm mount units shall be constructed of anodized 4. Optical Emitter Type: 850nm LED aluminum. 5. Transmitter Output Power: 25µw (-16 dB) E. Weight: <2.0 lbs./1.0kg 6. Optical Detector Type: 850nm PIN DIODE 2.10 ENVIRONMENTAL SPECIFICATIONS 7. Receiver Sensitivity: 1µw (-30 dB) A. MTBF: >100,000 Hours 8. Optical Power Budget: 14 dB B. Operating Temp: –40˚ C to +74˚ C 9. Optical Attenuation: No manual adjustments C. Storage Temp: -40˚ C to +85˚ C required D. Relative Humidity: 0% to 95% (non- B. IFS Model Number D2315-1300 condensing). If product is installed under 1. Optical Fiber: 62.5/125 micron multimode condensation conditions, unit shall have 2. Number of Fibers Required: 4 conformal coating applied to the printed circuit 3. Optical Wavelength: 1300nm board. (Add –C to model number for conformal 4. Optical Emitter Type: 1300nm LED coated printed circuit board) 5. Transmitter Output Power: 20µw (-17 dB) 2.11 REGULATORY AGENCIES/APPROVALS 6. Optical Detector Type: 1300nm PIN DIODE AND LISTINGS 7. Receiver Sensitivity: 1µw (-30 dB) A. Underwriters Laboratory (UL) Listing Number: 8. Optical Power Budget: 13 dB I.T.E. 6D16 9. Optical Attenuation: No manual adjustments B. Underwriters Laboratory Canada (ULC) Listing required Number: I.T.E. 6D16 C. IFS Model Number D2315-SM C. UL 94-flame rated PCB board: 94VO 1. Optical Fiber: 9/125 micron single-mode 2.12 ACCESSORIES 2. Number of Fibers Required: 4 A. Card Cage: IFS Model Number R3 (EIA 19” 3. Optical Wavelength: 1300nm card cage) shall be available to house and power 4. Optical Emitter Type: 1300nm LED rack mount modules. 5. Transmitter Output Power: 25µw (-16 dB) B. Blank Panels: IFS Model Number R3-BP shall 6. Optical Detector Type: 1300nm PIN DIODE be available to cover unused rack slots. 7. Receiver Sensitivity: 1µw (-30 dB) PART 3 - EXECUTION 8. Optical Power Budget: 14 dB 3.1 EXAMINATION 9. Optical Attenuation: No manual adjustments A. Inspect modules before installation. required B. Modules shall be free of any cosmetic defects or 2.6 STATUS INDICATORS damage. A. Power: On/Red – Off/Off C. All optical connectors shall be covered with dust B. Data Transmit: Data Transmit/Green – No caps and remain on the module until installing Data/Off cable connectors to module. C. Data Receive: Data Receive/Yellow – No D. Shipping box shall include the module, power Data/Off supply and operations manual. 2.7 CONNECTORS 3.2 PREPARATION A. Optical: ST A. Standalone Module (Surface Mount) B. Power and Data: Terminal Block with Screw 1. Shall be mounted on a properly prepared Clamps surface adequate for the size and weight of 2.8 ELECTRICAL SPECIFICATIONS module. The placement of the unit shall A. Power: 12 to 48 VDC allow provision for cable installation and B. Current Protection: Automatic re-settable solid- maintenance as indicated on the approved state current limiters detail drawings and in compliance with the C. Voltage Regulation: Solid-state, Independent on IFS mounting template and installation each board manual. D. Circuit Board: UL 94 flame rated and meets all B. Rack Mount Module (19” Rack) PCI standards. 1. Shall be installed in the IFS Model Number E. Rack mount Card: Shall be hot-swappable with R3 card cage. Ensure the card cage is IFS Model Number R3 (EIA 19” card cage) installed in a standard EIA 19” (482.6 mm) 2.9 MECHANICAL SPECIFICATIONS rack or wall standoff bracket adequate for A. Surface Mount Dimensions: 7.1” x 4.9” x 1.0” the size and weight of the card cage. The (18.00 cm x 12.45 cm x 2.54 cm) placement of the unit shall allow provision B. Rack Mount Dimensions: 7.7” x 5.0” x 1.0” for cable installation and maintenance as (19.55 cm x 12.70 cm x 2.54 cm) indicated on the approved detail drawings and in compliance with the IFS installation with dust caps until connection to the fiber manual. optic module. C. Optical Fibers 3.3 INSTALLATION 1. Caution: NEVER look into the end of an A. General: Locate fiber optic modules as indicated active optical fiber when using laser light on the approved detail drawings and install output. Eye damage can occur. Wear eye module in compliance with the IFS installation protection when cleaving, terminating, and and operations manual. splicing fiber. 3.4 TESTING 2. The number and type (multimode or single- A. Testing the Fiber Optic Data Link. mode) of optical fiber shall meet the 1. Verify that the data leads and optical fibers requirements of the IFS model number in are properly connected. article 2.05 used in the installation. 2. Make sure that power is applied to all fiber 3. All optical fiber cables shall be properly optic modules, controllers, and receiver installed and terminated with the mating drivers or other equipment used in the optical connectors as submitted in article system. 2.07 (A). 3. Successful data link operation should be 4. The optical link shall be tested with either a confirmed at this point by using the power meter, at a minimum, or OTDR to controller to pan, tilt, and zoom the camera ensure the link budget (overall path loss) or communicate with other equipment. plus an added 3dB of optical safety margin 3.5 CLEANING does not exceed the optical power budget as A. Follow all instructions for proper use of solvents submitted in article 2.05. and adhesives used for termination and splicing. 5. All optical connectors on cable shall be B. At completion of the installation, dispose of all cleaned in compliance to optical connector fiber scraps properly. manufactures specifications and covered MANUFACTURED UNITS REFERENCE TABLES

Table A: Product Number Descriptions

MAX. DISTANCE* 2.5 Miles (4KM) 2.5 Miles (4KM)

8 Miles (13KM) 8 Miles (13KM)

25 Miles (40KM) 25 Miles (40KM)

* Maximum distance is limited to optical loss of the fiber and any additional loss by connectors, splices and patch panels.

Table B: Product Compatibility Chart

REPEATER D2315 D2315-R3 D2315-1300 D2315-1300-R3 D2315-SM D2315-SM-R3

END OF SECTION