1 2 3 4 5 6 Date & Vessel Name, Flag Owners Classification Summary Place of Type, IMO No & Operator Society Detention GT Charterers 5/01/2010 ATRA Malta Horizon Hellenic Detained for 10 days. Denizcilik Register of 20 recorded deficiencies. Koper General cargo Shipping Bridge corroded through. Turkey On STB side ship’s hull 8802337 repaired with improper size doubler. In 6.066 acetylene room hull holed. Bridge alleyway bulkhead corroded through. Front bridge corroded through. In wheelhouse one clear view window inoperative. Cabin door threshold not as required. Air vent cover on emergency diesel generator room corroded through. Anchor light on FCSL with improper glass. Masts navigational lights with improper corrugated glasses. In FCSL bulkhead between chain locker and boatswain store corroded through. Quick closing valve on FO day tank to be repaired. Sight glass on DG expansion tank cracked. Three pipes on sewage treatment plant in very bad condition. One hydrophore pump inoperative. All ER floors not fixed. Outlet boiler valve leaking. ME sea water pump platform corroded through. ER bilge full. Content to be emptied in bilge tank. In ER PS one frame and hull severely wasted. 08/01/2010 LIM St Vincent Anamila Germanischer Detained for 3 days. & d.o.o. Lloyd One recorded deficiency. Koper General cargo Grenadine Bunker certificate Croatia missing. 8407747

8.639 22/02/2010 CHRISTINA Sierra Success Dromon Detained for 5 days. Leone M&S S.A. Bureau of 34 recorded deficiencies. Koper General cargo Shipping Chart 1471 missing. Greece Clear view glass window 6814130 inoperative. Wheelhouse bulkhead corroded 1.242 through. Air condition cables improperly installed through cabins’ bulkheads. ER air vent corroded through. Bridge deck repaired with tape and silicone. On paint room air vent missing. Standard discharge connection flange with rubber pipe connection. Galley bulkhead corroded through. Tween deck in hold 1 corroded through. Four frames in hold 1 corroded through. Longitudinal semi bulkhead in hold 1 corroded through. Tween deck in hold 2 corroded through. Hatch covers frames on hold 3 corroded through. In FCSL port side 5 consecutive frame corners bent. On FCSL bell missing. FCSL bulkhead corroded through. Front bridge bulkhead corroded through. AB cabin window frame detached. PS entrance door gasket holder corroded through. Oiler cabin bulkhead corroded through. Galley bulkhead corroded through. Bilge under diesel generators and ER bilge to be dried and cleaned. Steering gear hatchway corroded through. Lighting in boatswain store and steering gear room not as required. In steering gear room 1 beam cracked and 1 beam bent. Emergency steering gear inoperative. Electrical cable on hot water valve disconnected. Oily rags and changed dirty oil to be properly disposed. Line for discharge sludge to shore made of plastic. ME fuel leaking alarm inoperative. Grey water lines temporary repaired. ME air collector temporary repaired. MNC – maintenance of ship and equipment failed. 25/02/2010 GUO DIAN 6 China Shanghai China Detained for 2 days. Fuijan Classification 3 recorded deficiencies. Koper Bulk carrier Guohan Society Bunker certificate missing. Due to ship 9061875 China grounding CS safety certificate invalid. Due to 35.874 ship grounding LL certificate invalid.

18/03/2010 DANIEL STAR Syria ISM Group International Detained for 4 days. Register of 28 recorded deficiencies. Koper General cargo Syria Shipping Bunker certificate missing. Company name 6726199 on DOC and SMC not identical. On PS hull 1.996 scuppers welded. Difference between gyro compass and gyro repeaters 105°. Main magnetic compass with big bubble and blocked in gimble. Air condition cables improperly installed through cabins’ bulkheads. Cover on galley sky light corroded through. Glass on stern navigational light with improper corrugation. On hold 2 several frames on hatch covers corroded through. Bulkhead between hold 1 and hold 2 corroded through in several places. In hold 1 PS 8 frames corroded through. In hold 1 PS 13 frames bent. In Hold 1 STB 6 frames corroded through. In Hold 1 for frames bent. In ER and FCSL electrical cables exposed. FCSL bulkhead corroded through. On FCSL 2 bollards and on poop 1 bollard damaged and bollards bases corroded through. On FCSL hydraulic oil leaking on PS cargo winch. On FCSL cargo winches bases corroded through. Poop deck over steering gear room not watertight. Main fire line in steering gear room corroded through. Quick closing valve on settling tank blocked with wire. ME cooling water line temporary repaired. Generators cooling water lines temporary repaired on several places. Former DG cooling water valve can be used as illegal discharge line. Glass on store door window cracked. MNC – maintenance of ship and equipment failed. 02/04/2010 KATERINI Panama Doron Overseas Detained for 7 days. Shipping Marine 17 recorded deficiencies. Koper General cargo STB enforcement anchor Greece plate corroded through. 8004129 Stern draft marks not readable. Steps damage 3.145 on STB ladder for reading draft. Sludge and bilge tanks almost full. Certificate for OFE missing. Deviation of main magnetic compass -15°. Bulkhead on safety equipment store corroded through. On paint room air vent missing. Chart 1471 missing. In hold 1 five frames damaged. One frame cracked. On hold 1 PS nine frames damaged. Top of the DB 1 tank temporary repaired. PS DB1 air pipe corroded through. On STB DB4 and FW air pipes corroded through. One washing machine inoperative. Crews’ toilets without sitting desks. Meat room temperature -10° C. MNC – maintenance of ship and equipment failed. 06/04/2010 HEIDI H Cambodia Heidi H Live Columbus Detained for 3 days. Stock American 12 recorded deficiencies. Koper General cargo Shipping Register Access control not as 5098129 Lebanon required. Chart 1471 not up to date. Clear view 399 window inoperative. Port side navigational light with improper corrugated glass. Satellite EPIRB inoperative. Main magnetic compass with big air bubble and sized in gimble. Anchor ball improper size and shape. Main fire line holed. FCSL door gasket missing. On paint room air vent missing. Electrical cables on emergency fire pump exposed. Battery for emergency fire pump inoperative. Emergency fire pump insufficient pressure. 29/04/2010 MASTER Sierra Cata Maritime Lloyd Detained for 6 days. FAWAZ Leone Shipping 33 recorded deficiencies. Koper Management PS gangway platform General cargo damaged. 3 lower steps Syria on pilot ladder damaged. 7519921 PS hull repaired with improper doubler. Charts 3.442 1471 and 204 not up to date. Shadow on side red navigational light detached. On side green light, stern anchor light and stern navigational light glasses cracked. Anchor ball improper size and shape. PS man over board heavily damaged. Wheelhouse bulkhead corroded through. Main magnetic compass with big air bubble. Deviation on main magnetic compass 35°. Difference between gyro and gyro repeaters 82°. Hatch covers frames corroded through. In lower hold several frames corroded through. In tween deck several frames corroded through. In TD gusset plates between frames corroded through. In TD FWD beams corroded through. In TD web frames damaged, corroded through, one detached on top. Frames on both hold entrances corroded through. In TD FWD bulkhead corroded through. Emergency fire pump insufficient pressure. FP and PS aft tank air pipes corroded through. On STB windfalls base corroded through. All saves all under tanks air pipes corroded through. Additional pipe fitted on standard discharge connection flange. Deck in steering gear room slippery. Sludge pump with additional pipe connection. ER bilge to be dried and cleaned. Main engine fuel leaking alarm inoperative. Fuel leaking collection tank improper size. Flange on obsolete OFE valve to be welded. Rescue boat engine inoperative. Abandon ship drill failed. MNC – maintenance of ship and equipment failed. 10/06/2010 TINAZTEPE – S Turkey Yiltur Deniz Turkish Lloyd Detained for 7 days. 18 recorded deficiencies. Koper General cargo Turkey Master has no cargo information. Glass on 7505798 clear view window cracked and inoperative. 1.900 Gasket holder on air condition room door corroded through. Gasket holder on ER air vent cover corroded through. Gasket holder on STB main entrance door corroded through. Derrick base corroded through. On hold No 2 aft cargo winch hydraulic oil leaking. Several hatch covers frames on hold 2 corroded through. Some hatch covers wheels supports cracked. Hatch covers frames on hol1 corroded through. One hatch cover corroded through. Two hatch coaming frames on hold No 2 corroded through. Five hatch coaming frames on hold No 1 corroded through. ME cooling water line temporary repaired. ME se water line temporary repaired. Hydraulic line between ER and steering gear room made of rubber. Quick closing valve on burner settling tank inoperative. Abandon drill failed. MNC – maintenance of ship and equipment failed. 01/07/2010 MAYA 1 Panama Euroshipping Panama Detained for 3 days. Maritime 20 recorded deficiencies. Koper General cargo Slovenia Surveyors Bunker certificate Bureau missing. PS gangway 7305526 holed in several places. Navtex inoperative. VHF 1.926 GMDSS equipment battery for watch inoperative. Hatch covers frames on hold No 2 corroded through. Hatch covers frames on hold No 1 corroded through. On windlass hydraulic oil leaking. Cargo winch on hold No 2 FWD hydraulic oil leaking. Winch base corroded through. In hold No 2 three frames’ faces corroded through. One detached. Behind main electrical panel antistatic carpet missing. Propeller shaft revolution counter not as required. Small sludge tank not inserted in IOPP certificate. From bilge tank on shore discharge line additional flange installed for direct discharge from ER bilge. All ER floors not fixed. Main engine fuel leaking alarm inoperative. Maine engine without spare head. Sludge, bilge and ME fuel tanks sounding pipes without covers. One fire hose leaking. On emergency fire pump manometer missing. Support of ER crane unsafe. 02/07/2010 ANITA Cook Alexandra International Detained for 5 days. Island Mgmnt Naval Survey 17 recorded deficiencies. Koper General cargo Bureau Wheelhouse bulkheads Norway corroded through. Some 7396654 charts for intended voyage missing and 2.627 some not up to date. On wheelhouse one clear view screen window inoperative. Side red, green and stern anchor light with improper corrugated glasses. Magnetic compass does not move freely in gimble. Both ER air vents corroded through. STB aft hold air vent cover corroded through. Main fire line temporary repaired with clamps. STB FWD hold one frame bracket corroded through, one bent. STB FWD hold one beam corroded through. Air vent cover in FWD hold corroded through. Paint room door threshold not air tight. In FCSL rubber pipe connected to FW manhole cover. On PS two air pipes ball protections corroded through. Winch base of PS lifeboat corroded through. Bilge pump connected to holding tank with rubber pipe. Fuel line connected to FW ER bilge with rubber pipe. 03/07/2010 ST.ELIZABETH Moldova West Russian Detained for 7 days. Management Maritime 22 recorded deficiencies. Koper General cargo Register of Antifouling certificate Ukraine Shipping missing. Oil filtering 8313104 equipment type certificate missing. Air 3.921 condition inoperative. On galley window glass cracked. Front bridge bulkhead corroded through. In hold No two 16 frames’ brackets damaged in detached. In hold No 2 two frames corroded through. In hold No 2 several gusset plates between frames bent. Anchor ball improper size. On FCSL bell missing. On paint room air vent missing. FCSL bulkhead on boatswain store corroded through. In FCSL hydraulic pipe temporary repaired with clamps. In ER fresh water line leaking. Rubber pipes in ER to be removed. On hull obsolete FW outlet valve can be used as illegal discharge. On two main engine cylinders cooling water leaking. STB lifeboat’s davit corroded through. Crew does not use safety personal equipment. Abandon drill failed. Insufficient speed of STB lifeboat. MNC- Maintenance of ship and equipment failed. 17/07/2010 B.M.SPIRIDON Comoros Rami Phoenix Detained for 1 day. Shipping Register of 11 recorded deficiencies. Koper Livestock Management Shipping All navigational lights with improper corrugated 6727272 Lebanon glasses. Bridge bulkhead corroded through. 1.540 Magnetic compass sized in gimble. Mess room bulkhead corroded through. In FCSL last frame corroded through. In FCSL STB last and one before last frames improperly welded. Anchor ball to small. Ball protection on FP air pipe corroded through. ME fuel leaking alarm inoperative. Hull corroded through. On sludge tank manhole cover not bolted. 17/07/2010 HAY K Moldova Tango Bulgarski Detained for 4 days. Shipping Co. Koraben 9 registered deficiencies. Koper General cargo Registar DOC invalid. One Turkey GMDSS radio operator 8003864 missing. Four cabins’ ventilators to be 1.082 acquired. Contents of ER bilge to be discharged on shore. Air condition cables improperly installed through bridge bulkhead. Ball protection on PS WB4 air pipe corroded through. On FCSL bell missing. Head of FW air pipe corroded through. Head of AP air pipe cracked. 20/07/2010 RIHAB Comoros Rania Marina International Detained for 2 days. Naval Survey 16 recorded deficiencies. Koper Livestock Marshall Bureau Bunker certificate Islands missing. Main magnetic 6829082 compass with air bubbles. Deviation of 1.372 main magnetic compass 16°. In lower hold 6 frames corroded through. In lower hold FWD and aft deck centre girders corroded through. In lower tween deck 4 frames corroded through. In upper tween deck 5 frames corroded through. On FCSL VFT air pipe ball protection corroded through. Plastic can used for anchor ball. On FCSL anchor light missing. FP manhole cover not bolted. B FP air pipe corroded through. Both chain pipes corroded through. Windlass base corroded through. Base of FWD and aft cargo winches corroded through. Aft hold air vent corroded through. 02/08/2010 ARTEMIS Albania Albartin Register of Detained for 3 days. Shipping Shipping 24 recorded deficiencies. Koper General cargo Albania In wheelhouse one Albania screen view window 7600873 inoperative. Steps on ladder for access to 2.205 bridge deck corroded through. Air condition room bulkhead corroded through. Wheelhouse bulkhead corroded through. Stern navigational light with damaged glass. In ME emergency exit light inoperative. In PS aft hold two frames brackets damaged. Inside double hull plating holed. On aft hatch coaming two corners damaged. On aft hold ladder 3 steps damaged. On front bridge 2 air pipes corroded through. FWD hatch covers nad hatch covers frames corroded through. Both chain pipes corroded through. Both DB 1 air pipes corroded through. Main fire line corroded through. CO2 room air vent ball protection corroded through. FWD hold entrance inner gasket holder corroded through. Synchronisation of auxiliary engines inoperative. Quick closing valve on ME service tank blocked with wire. Oil filtering equipment inoperative. Pivots on davit launching devices with excessive clearance. Lifeboat speed insufficient. Abandon drill failed. Crew does not use personal protective equipment. 05/08/2010 KHALIFEH Honduras Sea shipping Croatian Detained for 1 day. LIVESTOCK & chartering register of 16 recorded deficiencies. Koper Shipping On bridge 4 windows Livestock Lebanon cracked. Rubber gaskets on fire hydrants worn. 7026871 Gyro repeater 128° difference. Magnetic 3.356 compass with air bubbles. Wheelhouse wipers inoperative. Navigational light not visible. Air condition cables improperly installed through bulkheads. Door on boat deck unable to close. FWD spring wire damaged. ER emergency exit obstructed. Garbage not properly segregated. Conformance test not original. Lifeboat release hook sized. Lifeboat davit mechanism with excessive clearance. ISM Maintenance of ship and equipment failed. 16/08/2010 HARMONIA Moldova Management Maritime Detained for 6 days. operator Bureau of 19 recorded deficiencies. Koper General cargo Shipping DOC expired. MNC – risk Greece assessment missing. 7530884 Wheelhouse bulkheads corroded through. Air 1.992 condition room bulkhead corroded through. Alleyway door threshold through. AP air pipe ball protection corroded through. On STB six air pipes corroded through. On FCSL FP air pipes corroded through. On PS nine air pipes corroded through. In hold five frames bent. In hold two frames corroded through. FWD STB inner double hull holed. Windlass base plate corroded through. Top of rope store ladder detached. On OFE outlet line additional pipe installed as illegal discharge. All rubber pipes in ER to be removed. STB main rail on rescue boat damaged. Abandon drill failed. MNC- maintenance of ship and equipment failed. 18/08/2010 HEIDI H Cambodia Heidi H Columbus Detained for two days. livestock American 17 recorded deficiencies. Koper General cargo Shipping Co. Register Navigational lights with improper corrugated 5098129 Lebanon glasses. Not possible to lower rescue boat. 399 Hoisting wires on davits sized. Gangway handrail unsafe. Fire hoses leaking. Emergency fire pump inoperative. Portable GMDSS radios improperly used. Steering gear oil leaks. Quick closing valve on settling tank inoperative. Electric wires not insulated. Deck lights detached from supports. Entries in ORB missing. Bilge pump inoperative. ER bilge to be emptied. ISM risk assessment missing. MNC maintenance of ship and equipment failed. 10/09/2010 KEREM Turkey Yimaz Turkish Lloyd Detained for 5 days. AYANOGLU Denizcilik 18 recorded deficiencies. Koper ME skylight and skylight General cargo Turkey cover corroded through. 7364273 Air condition cables improperly installed 1.998 through cabins bulkheads. Funnel corroded through. Toilet bulkhead corroded through. Chief mate cabin bulkhead corroded through. Cook cabin bulkhead corroded through. Two saves all under DO air pipes corroded through. On hold No. 2 several hatch covers frames corroded through. On hold No. 1 several hatch covers frames corroded through. Bulkhead between hold 1 and hold 2 holed. In hold No. 2 mid girder plate 4 frame corners detached. In hold No. 2 several frames and frames faces bent. Mast house deck corroded through. Mast house door corroded through. On FCSL rope store cover corroded through. FWD STB hold No. 1 air vent corroded through. Emergency fire pump insufficient pressure. MNC- maintenance of ship and equipment failed. 15/09/2010 AG NIKOLAS Panama Diamonds Universal Detained for 16 days. Shipping & Shipping 23 recorded deficiencies. Koper General cargo Trading Bureau Security plan not approved. Risk 7627467 Greece assessment plan missing. Two red lights 2.824 for ship not under command with improper glasses. ER air vent damper sized. In battery room protective equipment missing. Crew does not use protective personal equipment. Inner gasket holder on battery room door corroded through. Rescue boat engine inoperative. On hold No. 2 hatch covers corroded through. On hold No. 1 hatch covers corroded through. Ball protection on FP air pipe corroded through. On FCSL V store air vent corroded through. In paint room on lights protective glasses missing. On DG 1 floater of fuel leaking alarm detached. On both steering gear cylinders oil leaking. FW evaporator outboard line temporary repaired with concrete. In steering gear room deck under lavatory corroded through. In steering gear room grey water line corroded through. Diesel generator cooling water line corroded through. Emergency fire pump without pressure. Sludge and bilge lines connected. OFE inoperative. MNC- maintenance of ship and equipment failed. 22/09/2010 RABUNION 20 Syria Rabunion Turkish Lloyd Detained for 2 days. Maritime 23 recorded deficiencies. Koper Livestock Agency Bunker certificate missing. 4 crew 6817003 Lebanon members medical certificates missing. 1.443 Records of rest false. Oil record book entries missing. Magnetic compass with air bubbles. Two mooring lines in bad condition. Gangway missing. Funnel corroded through. Bridge windows frames corroded through. Rubber gasket on pain room frame corroded through. Accommodation door corroded through. On accommodation air vents dampers missing. On ER air vent damper sized. Hoses leaking. Light bulb protection damaged or missing. Wire mesh on fuel and fresh water air pipes missing. Winch basement on aft derrick corroded through. Laundry room used as paint room. ER bilge to be dry and clean. Garbage not properly stowed and segregated. Galley, toilets and crew cabins dirty. MNC- maintenance of ship and equipment failed. 28/09/2010 MB SPIRIDON Comoros Rami Phoenix Detained for 3 days. Shipping Register of 23 recorded deficiencies. Koper Livestock Management Shipping Hull corroded through. Wheelhouse bulkhead 6727272 Lebanon corroded through. On PS aft lifeboat davit joint pin 1.540 coming out. One frame on PS lifeboat winch base corroded through. Air condition cables improperly installed through cabins bulkheads. ER air vents corroded through. Gasket missing on ER air vent cover. Air vent on PS generator room corroded through. Inner gasket holder on ER skylight cover corroded through. Hatchway cover on ER emergency exit corroded through. Deck before main entrance corroded through. Ball and ball protection on air pie for FW1 tank missing. Hatch coaming between decks corroded through. Ship’s bulwark corroded through in several places. In hold several air vent trunks corroded through. In UTD several frames corroded through. On PS seven consecutive frames bent. In LTD several frames corroded through. In LTD several corroded through frames improperly repaired. On ER hull 2 obsolete valves flanges to be welded to prevent possible illegal discharge. On paint room air vent missing. Electric cables in holds and on some panels exposed. MNC-maintenance of ship and equipment failed. 30/09/2010 SENATOR – 1 Russian TESK sev in Russian Detained for 2 days. federation Transs maritime 9 recorded deficiencies. Koper General cargo register of Two headlines in bad Russian shipping condition. Bridge 8942668 Federation lifebuoys worn. Pilot ladder not as required. 1.777 PS aft railing damaged. Mesh wires missing on FW air pipes. Crew does not use personal protective equipment. In ORB weekly entries missing. Bunker certificate missing. Anti fouling certificate missing. 13/10/2010 DELPHINUS Comoros Vassiliev Russian Detained for 4 days. Maritime Maritime 13 recorded deficiencies. Koper General cargo Register of Wheelhouse window Istanbul Shipping glass cracked. 8871687 Wheelhouse bulkhead Turkey corroded through. Hinges 2.979 on ER air vent covers damaged. Bulkhead on captain cabin corroded through. In FCSL 4 consecutive frames bent. In ER 8 consecutive frames and 2 bulkheads bent. In ER STB 4 consecutive frames bent. Hold air vent corroded through. Crew does not use personal protective equipment. STB lifeboat inoperative. STB lifeboat insufficient speed. Abandon drill failed. MNC – lack of training. 27/10/2010 ALI AGA Turkey Beykoz Turkish Lloyd Detained for 2 days. Denizcilik 15 recorded deficiencies. Koper General cargo Ship overloaded. Safety Istanbul net not posted under 8121719 gangway. IOPP Turkey supplement certificate 1.998 not as required. Funnel door corroded through. Funnel artificially holed. Masts and side lights with improper glasses. Windows frames detached. On FCSL store air vent cover cannot be closed. Hull unauthorised repaired. On fuel settling tank QCV inoperative. Fuel tank gauges blocked in open position. Crew does not use protective personal equipment. On STB railing one stanchion damaged. Rescue boat engine inoperative. Abandon drill failed. 11/11/2010 VELES Moldova Niesco Shipping Detained for 10 days. Shipping Register of 19 recorded deficiencies. Koper General cargo Ukraine Stern navigational light Ukraine with improper glass. 8857980 GMDSS battery box corroded through. Door 2.432 on bridge corroded through. Accommodation door on main deck corroded through. Boatswain and paint store doors corroded through. Catwalks corroded through. Lights around accommodation containing water. Steps on poop deck corroded through. Some save alls corroded through. Crew does not use personal protective equipment. ER bilge dirty. ME fuel suction pipe temporary repaired. Bilge pump discharge line connected directly overboard. Accommodation bulkhead corroded through. ER skylights corroded through. Hold No. 4 hatch coaming frames corroded through. PS lifeboat inoperative. Lifeboat davits sized. MNC-maintenance of ship and equipment failed. 15/11/2010 VIKTOR Ukraine Donbass Shipping Detained for 10 days. KHARA Register of On PS bulwark 7 frames Koper Ukraine Ukraine detached. One General cargo wheelhouse window glass cracked. Funnel 8033247 door corroded through. Battery room bulkhead 4.694 corroded through. ER air vent corroded through. On boat deck both alleyways corroded through. Lifeboat hull cracked. Some unauthorised repair performed on lifeboat. Store bulkhead corroded through. Galley door and door frame corroded through. Last step on pilot ladder damaged. On hold No. 3 several hatch covers frames corroded through. On hold No. 2 hatch covers frames corroded through. Hatch coaming on holds 2&3 frames corroded through. On mast house both doors corroded through. PS chain pipe corroded through. 21/12/2010 DANIEL STAR Syria Deniz International Detained for 7 days. Maritime register of 18 recorded deficiencies. Koper General cargo Shipping STB aft hull corroded Syria through. Deviation of 6726199 magnetic compass 7°. Ship does not keep 1996 deviation records in compass correction log. In main magnetic compass half liquid missing. Red and green side lights with glasses cracked. Bridge bulkheads not weather tight. Galley air vent damper sized. In hold 1 several frames bent and corroded through. On STB anchor stud chain 4 links stays to be welded. FCSL bulkhead corroded through. Scupper line in steering gear room corroded through. On mast house hydraulic line holed. On grinding and drilling machines protections missing. Part of sewage line made of rubber. On STB hull 2 obsolete flanges to be welded to prevent outboard illegal discharge. PS lifeboat main rail on bow damaged. Both davits on PS lifeboat corroded through. On STB aft hold 2 one hatch coaming stay corroded through. 30/12/2010 LETFALLAH V Tanzania Cata Bulgarski Detained for 2 days. Shipping Co. Koraben 22 recorded deficiencies. Koper General cargo Registar On captain’s cabin Syria window glass cracked. 8003929 Two windows frames on front bridge detached 5307 due to corrosion. Alleyway and gym room bulkhead corroded through. All air condition cables improperly installed through cabins’ bulkheads. Hand grip on PS lifeboat damaged. Hatch covers hydraulic pipes leaking. Hold No. 1 FWD and aft hatch coaming longitudinal bracket corroded through. In TD on FWD fuel deep tank air pipes additional pipes added for sounding the tanks. On holds 1&2 several hatch covers frames wasted due to corrosion. FCSL door on FWD mast corroded through. PS windlass base corroded through. STB windlass electromotor heavily corroded. In FCSL hold No.1 air vent duct cracked and corroded through. Main fire line temporary repaired with clamp. Emergency fire pump insufficient pressure. Several tank gauges blocked in open position. In ER labels and instruction not in working language. Oil mist detector on main engine inoperative. Sludge pump connected with rubber pipe. Several rubber pipes connected to the opening on top of the overflow tank. On obsolete OFE outboard line additional valve installed which can be used for illegal discharge. Tank size discrepancy between IOPP and exemption certificate.

Recommended publications