**1065 mil control bro 1/15/02 3:36 PM Page 2

EDWARDS SIGNAL SOLUTIONS www.edwards-signals.com

Reliable, versatile signaling performance and control.

Adaptatone® SERIES **1065 mil control bro 1/15/02 3:36 PM Page 3

EDWARDS ADAPTATONE MILLENNIUM SERIES

Clear, effective, flexible signaling command for routine and emergency plant-wide communications.

Edwards Adaptatone Millennium multiple-tone electronic signals offer the widest selection of tones in the industry. With short code blasts or sustained warning signals, they meet virtually every application requirement – from emergency evacuation to routine communications.

27 tones, voice and system paging – the Adaptatone signaling system provides for integrated plant-wide com- munications with microprocessor reliability. Choose from voice, telephone paging or field-programmable voice units that command notice and allow instant multi-lingual recognition of your factory’s operational status.

Now you can maximize control and flexibility, with the Millennium System Master. Easy to configure and easy to use, the System Master supervised control panel integrates all your plant-wide signaling needs.

2 **1065 mil control bro 1/15/02 3:36 PM Page 4

Reliable, versatile signaling performance –

Get your message heard. Capable of remote telephone paging from most telephone 27 unique tones that get your message across. systems when used with Cat. No. 5540MP.* Soft tones and melodies for your office areas. Alarming tones that cut through the din of your noisiest production areas. Tones are easily selected by setting internal miniature switches. No tone modules are ever needed. Plus field-recordable voice messages and system-wide voice and tele- phone paging to distinctly and accurately reach every ear in your facility.

Rugged and smart construction. Durable – cast construction with corrosion- All Millennium units feature captive screws, an external mounting resistant heat-flowed epoxy finish to stand up flange, opto-isolated activation to your harshest environment. Smart – captive inputs, and large wiring terminals. components that won’t get dropped and lost during installation. Easy pipe or surface mounting using the integral, external mounting flange. No special tools required – field wiring terminals can be operated with standard electrician screw- drivers. Hassle-free installation – large internal wiring compartment that gives you room to work.

Versatile and expandable. As your needs grow, so can your Adaptatone Millennium system. Each unit ships complete for Cat. No. 5542RPU-M remote easy standalone installation. And, by using a central paging unit with hand-held microphone. tone generator and simply connecting speaker amplifiers, you can construct a complete system for plant-wide warning and evacuation. Millennium models are available in a wide voltage range for non-hazardous and Division 2 hazardous locations. Connections are provided for external battery backup. Choose from standard 15-watt, and high- volume 30-watt units.

Ultimate control. You can take your system to the next level of flex- ibility, useability and control with the Millennium System Master supervised control panel. Designed for real-world applications, System Master can integrate and control all your communications – old and new – from a single point.

*Check with Edwards for specific connection methods for your phone system 3 **1065 mil control bro 1/15/02 3:37 PM Page 5

Adaptatone Millennium Series Multi-tone Electronic Signals

5536M Series Local/System Signal More activation methods Ð dry contact, 24VDC Accepts three electrical inputs and delivers three and 120VAC voltage input, PLC output RS485. tones from the available 27. One of the inputs is designated as a top-priority signal. The 5536M More tones, voice-recorded messages, micro- works in the Adaptatone system, either sound- phone and telephone paging. Reliable and ing the centrally produced tone or voice versatile signaling performance. signal or its own tone signal. The Adaptatone system has priority over the locally initiated tones. Weather- proof and suitable for Division 2 5530M Series Speaker/Amplifier locations. 30-watt high-volume Single Input, Single Output models available. UL, cUL Listed Standalone 27 tones including four three-pulse and CE Marked. temporal tones. 15-watt output. Battery backup terminals. Weatherproof and suitable for Division 2 locations. Diode polarized and high-volume 30-watt output models. Available with serial inputs for use on RS485 Networks. UL, cUL Listed and CE Marked.

5531M Series Speaker/Amplifier Four Input, Four Output All the features of the 5530M Series but with four inputs and four outputs with cascading-type priority tone operation. The tone programmed in each higher priority location overrides the tones programmed in lower locations. Weatherproof and suitable for Divi- sion 2 locations. UL, cUL Listed and CE Marked.

5531MV Series Speaker/Amplifier, Voice Capability – Four Input, Four Output Four input, four output cascading-type priority tone and voice operation. Features 20 seconds of field- recordable voice messages in 5-second parts. Messages and tones are selected by setting miniature Cat. No. 5530M dip switches within the unit. Weatherproof and speaker/amplifier. suitable for Division 2 locations. UL, cUL Listed and CE Marked.

5532M Series Speaker/Amplifier 5540M Series Remote speaker/amplifier designed for operation Central Tone Generator with the 5540M Central Tone Generator. Operates Designed for centralized generation of all 27 tones and directly from local power sources, making it possible simultaneous synchronous signaling throughout the to connect these units to available voltage sources Adaptatone system. Four cascading-type priority oper- from 24V to 250V. Battery backup terminals. Weather- ating tones may be programmed into the unit. Battery proof and suitable for backup terminals. Weather- Division 2 locations. High- proof and suitable for volume 30-watt output Division 2 locations. models. Available with serial inputs for use on Available with serial RS485 Networks. UL, cUL inputs for use on RS485 Listed and CE Marked. Networks. UL, cUL Listed and CE Marked. 4 **1065 mil control bro 1/15/02 3:37 PM Page 6

5540MV Series Central Tone Generator 5542RPU Remote Paging Unit with Voice Capability Remote Paging Unit sends audio to the 5540MP. Input All the features of the 5540M but with four input, is received from the microphone input (optional), 1V four output pyramid-type priority tone and voice audio source or telephone system audio converted operation. Features 20 seconds of field-recorded using Bogen Telephone Access Module or equivalent. voice messages in 5-second parts. Messages Powered by the required 5540MP. Mounted in double- and tones are selected by setting miniature gang box. UL and cUL Listed. dip switches within the unit. Available with serial inputs for use on RS485 5542RPU-M Remote Paging Unit with Mic Networks. UL, cUL Listed and CE Identical to the 5542RPU but supplied complete with Marked. the 5542MIC-H hand-held microphone.

Cat. No. 5530MHV Paging Accessories high-volume speaker/amplifier. 5542MIC-H Hand-held Microphone 5542MIC-D Desktop Microphone Cat. No. 5542MIC-D 5542WPK Weatherproof desktop microphone. Mounting Kit For mounting the 5542RPU or 5542RPU-M

Cat. No. 5542RPU-M to provide Type 3R outdoor protection. remote paging unit with Includes weatherproof box and cover. hand-held microphone. Tone Selection Chart Tone Description dB Volume* Ding-Dong Percussive pairs of 700 and 570 Hz tones, damped to zero 98 Warble 575 and 770 Hz alternately, 87 ms each 104 Siren 600-1250 Hz up and down sweep in 8 Sec. 110 Stutter Percussive 470 Hz, 83 ms on, 109 ms off 99 Slow Whoop 600-1250 Hz upward sweep n 4 seconds 110 Beep 470 Hz, 0.55 seconds on, 0.55 seconds off 102 Chime 1 700 Hz percussive repeat at 1 Hz 98 Fast Whoop 600-1250 Hz upward sweep in 1 second 110 Hi/Lo 780 to 600 Hz alternately, 0.52 seconds each 105 Rapid Siren 600-1250 Hz up and down sweep in 0.25 Sec. 107 Yeow 1250-600 Hz downward sweep in 1.6 seconds and repeat 110 Horn 470 Hz continuous 102 Air Horn 370 Hz continuous 102 Dual Tone 450-500 Hz, 0.4 to 0.5 second cycle 103 Chime 2 575 Hz percussive repeat at 1 Hz. 96 3 Pulse Horn 470 Hz, 3 0.5 sec. pulses separated by 0.5 sec. followed 107 by a 1.5 sec. delay and repeat 3 Pulse 370 Hz, 3-0.5 sec. pulses separated by 0.5 sec. followed 107 Air Horn by a 1.5 second delay and repeat 3 Pulse 450-500 Hz, 0.4 to 0.5 sec. cycle, 3-0.5 sec. pulses separ- 105 Cat. No. 5540M Dual Tone ated by 0.5 sec. followed by a 1.5 sec. delay and repeat central tone generator. 3 Pulse 575 Hz, 3-0.5 second pulses separated by 0.5 sec. followed 95 Chime 2 by a 1.5 second delay and repeat Phasor 416-625 Hz up and down sweep in 13ms 102 5540MP Series Central Tone Generator Telephone 570 and 770 Hz alternately 50ms. each for 1.2s, 1.5s delay 103 with Microphone Paging Staircase 440-2000 Hz up and down steps, 750ms 107 3 Tone Alert 463, 641,and 869 Hz, 200ms each 1 sec delay 106 All the features of the 5540M, but also features simul- Presignal Chime 470 Hz percussive repeat at 1.5 Hz 95 taneous voice and telephone paging throughout the NFPA Whoop 422-775 Hz upward sweep 850 ms each, 1 sec. delay and repeat 104 Adaptatone system. Requires the 5542RPU Remote Westminster Two measures 411, 520, 407, 312 Hz 98 Paging Unit to operate, which is ordered separately. 3 Blind Mice Four Measures, 787, 714, 625, 952, 333 Hz 101 UL and cUL Listed. † dB ratings taken at 10 feet in an anechoic chamber with signal volume control set at maximum and measurements made on an "A" weighted scale with peak hold.

To hear all 27 programmable tones available visit our website at www.edwards-signals.com 5 **1065 mil control bro 1/15/02 3:37 PM Page 7

External relay outputs Multi-function power and true make for fast power and device connections flexibility for both emergency and routine signaling. Key lock for program lockout It’s all there. With a single Millennium System Master you take complete control of all your Trouble relay for remote emergency, evacuation and routine signaling. annuciation of trouble And you do it with functionality and features status that can turn plant-floor signaling into a powerful business tool. Paging microphone Command, Control, Integrate. for immediate announcements to The System Master control panel is your any or all zones new signaling communications center. Its simple touch programming keys and easy-to-read, 40-character LCD display make set up, operations and modifica- tions a snap.

Thanks to System Master’s Dynamic Zone Control™ (DZC) and its program- mable zone reconfiguration, you can leverage the signaling investments you’ve already made without the need for expensive rewiring. Program keys provide simple-touch com- Alert, Warn, Communicate. mands, updates and status checks Everybody on the plant floor gets the signal from System Master’s vast signal- ing capabilities. You get all these Millennium functions built in:

• 27 tones • Audio, voice and power supervision • Microphone and external input supervision • Up to four five-second, field- recordable voice messages • Hand-held microphone paging • Phone paging from your current PBX • Stand-by power for all functions Easy-access terminal • Up to 32 satellite units addressable screw connections help through RS485 you connect and integrate • Output and trouble relays designed for all your audible signals fail-safe operation instantly • Top, side and bottom knockouts for easy wire entry • LED Alarm and status indications • Easy to adjust output audio 1-watt panel speaker Plus, Millennium System Master meets all for easy monitoring OSHA self-monitoring, prioritization, and standby power requirements, as well as UL stan- dards for evacuation signaling. Add it all up and it’s easy to see everything is there to make Millennium System Master your single signal command center.

6 **1065 mil control bro 1/15/02 3:37 PM Page 8

elay outputs ast power and nnections Here’s how Millennium System Master puts you in command.

Plexiglas window allows status viewing

40-character LCD display for system status and command confirmation

Door lock secures system integrity

cut-away area to show internal features

Dual microprocessors control even complex 1-watt panel speaker configurations for easy monitoring 15-watt amplifier delivers all the power you need for voice and tones

To hear all 27 programmable tones available visit our website at www.edwards-signals.com 7 **1065 mil control bro 1/15/02 3:37 PM Page 9

Adapatatone System Components

5533B or 5545B Emergency plant warning, security intrusion, Hazardous Location process control monitoring, system paging. Remote Speaker Amplifiers Edwards Signaling has the depth and For system use with central tone generator in Division 1 locations. breadth of product to fulfill your plant-wide signaling requirements. 5535 Remote Amplifier Used when remote speakers are 5532M Series required. Amplifier output is a 70V Remote Speaker Amplifiers line with a maximum of 15 watts. For system operation with central tone generator. 15-watt and high- volume 30-watt models available. 5551B-2W Cone Speaker 4" cone speaker for indoor ceiling or wall mounting. 70V input volt- 5536M Series age. Four power taps – .25, .50, 1 Local/System Signal and 2 watts. Fire and moisture Three inputs deliver three tones with proof. one input designated as a priority sig- nal. 15-watt and high-volume 30-watt models. Available with serial inputs for use on RS485 Networks.

Typical Adaptatone System Configuration

Speaker/Amplifier Cat. No. 5532MHV Speaker/Amplifier Cat. No. 5532M Local/System Signal Hazardous Cat. No. 5536M Location 3 Local Tones Speaker/Amplifier Cat. No's. 5545B Central Tone Generator with paging Cat. No. 5540MP

4 wires 5 wires

Remote Amplifier Cat. No. Cat. No. 5535 5542RPU-M Reentrant 1V peak to peak Speaker audio source or Cat. No. 5547 Remote Signal Actuator telephone sys- Cat. No. 5538-4 tem audio con- for local inputs 2, 3, 4 verted using Bogen Cone Speaker Telephone Cat. No. Access Module 5551B or equivalent * Local Power 3 wires

8 **1065 mil control bro 1/15/02 3:38 PM Page 10

PRODUCT 5547-15W Reentrant Speaker 5510 Remote Audio Signal PHOTO TO 70V input voltage, high sound out- Converter COME put. Four power taps – 15, 8, 4 and Converts 25V or 70V RMS input 2 watts. Moisture resistant. ot 10V RMS output.

PRODUCT 5538-4 Series Millennium Retrofit Kits Remote Signal Actuator Designed for use in Adaptatone PHOTO TO Remote activation of up to four Millennium units to add the COME tones or messages. 5538-4R allows following: system to be interfaced to local/ system units for priority override. Audio-10-M: Adds 10V RMS System Audio

Audio-25-M: Adds 25V RMS System Audio

MR-201/C Relay Audio-70-M: Adds 70V RMS System Audio Used to enable the audio output from the 5540MP-24Y6 to override RS-485-M: Adds RS485 Networking output from other sources to the same speaker/amplifier products in Voice-M: Adds Field-programmable Voice the system.

Typical Adaptatone System Master Configuration

Speaker/Amplifier Speaker/Amplifier Cat. No. 5532MHV Cat. No. 5532M Local/System Signal Hazardous Cat. No. 5536M Location 3 Local Tones Speaker/Amplifier Cat. No's. 5545B Central Tone Generator with paging Cat. No. 5540MP

Need New System4 wires 5 wires

Remote Amplifier Cat. No. Cat. No. 5535 5542RPU-M Reentrant Master Diagram 1V peak to peak Speaker audio source or Cat. No. 5547 Remote Signal Actuator telephone sys- Cat. No. 5538-4 tem audio con- for local inputs 2, 3, 4 verted using Bogen Cone Speaker Telephone Cat. No. Access Module 5551B or equivalent * Local Power 3 wires

To hear all 27 programmable tones available visit our website at www.edwards-signals.com 9 **1065 mil control bro 1/15/02 3:38 PM Page 11

Input Signal Off Signal On Input Signal Off Signal On Card Standby Operating Card Standby Operating Activation Current Current Activation Current Current Cat. No. Volts Voltage (Amps) (Amps) Cat. No. Volts Voltage (Amps) (Amps) Speaker/Amplifier - One Input/Output Remote Amplifier 5530M-24AQ 24V DC 24VDC 0.10 0.74 5535-N5 120V AC 50/60 hz — 0.11 0.31 24V AC 50/60 Hz 0.10 1.3 5535-R5 240V AC 50/60 hz — 0.053 0.250 5530M-24N5 120V AC 50/60 Hz 24VDC 0.10 0.36 Local/System Signal 5530M-120N5 120VAC 0.10 0.38 5536M-24AQ 24V DC 24VDC 0.10 0.74 5530M-24Y6 120V AC 50/60 Hz 24VDC 0.10 0.32 24V AC 50/60 Hz 0.10 1.3 5530M-120Y6 240V AC 50/60 Hz 120VAC 0.10 0.20 5536M-24N5 120V AC 50/60 Hz 24VDC 0.10 0.36 125V DC 0.10 0.21 5536M-24Y6 120V AC 50/60 Hz 24VDC 0.10 0.32 250V DC 0.02 0.10 240V AC 50/60 Hz 0.10 0.20 5530MD-24AW* 20-31V DC 24VDC 0.10 0.85 125V DC 0.10 0.21 Speaker/Amplifier - One Input/Output - High Volume 250V DC 0.02 0.10 5530MHV-24AQ 24V DC 24VDC 0.10 1.5 Local/System Signal - High Volume 24V AC 50/60 Hz 0.10 2.3 5536MHV-24AQ 24V DC 24VDC 0.10 1.5 5530MHV-24Y6 120V AC 50/60 Hz 24VDC 0.10 0.62 24V AC 50/60 Hz 0.10 2.3 5530MHV-120Y6 240V AC 50/60 Hz 120VAC 0.07 0.37 5536MHV-24Y6 120V AC 50/60 Hz 24VDC 0.10 0.56 125V DC 0.10 0.40 240V AC 50/60 Hz 0.10 0.34 250V DC 0.02 0.20 125V DC 0.10 0.39 Speaker/Amplifier - Four Input/Output 250V DC 0.02 0.19 5531M-24AQ 24V DC 24VDC 0.10 0.74 Central Tone Generator 24V AC 50/60 Hz 0.10 1.3 5540M-24AQ 24V DC 24V DC 0.10 0.74 5531M-24N5 120V AC 50/60 Hz 24VDC 0.10 0.36 24V AC 50/60 Hz 0.10 1.3 5531M-120N5 120VDC 0.10 0.23 5540M-24N5 120V AC 60 Hz 24V DC 0.10 0.36 5531M-24Y6 120V AC 50/60 Hz 24VDC 0.10 0.32 5540M-120N5 120V AC 60 Hz 120V AC 0.10 0.38 5531M-120Y6 240V AC 50/60 Hz 120VAC 0.10 0.20 5540M-24Y6 120V AC 50/60 Hz 24V DC 0.10 0.32 125V DC 0.10 0.21 5540M-120Y6 240V AC 50/60 Hz 0.10 0.20 250V DC 0.02 0.10 125V DC 0.10 0.21 Speaker/Amplifier - Four Input/Output - High Volume 250V DC 0.02 0.10 5531MHV-24AQ 24V DC 24VDC 0.10 1.5 Central Tone Generator with Voice Messaging 24V AC 50/60 Hz 0.10 2.3 5540MV-24N5 120V AC 50/60 Hz 24VDC 0.10 0.36 5531MHV-24Y6 120V AC 50/60 HZ 24VDC 0.10 0.62 5540MV-24Y6 120V AC 50/60 Hz 24VDC 0.10 0.32 5531MHV-120Y6 240V AC 50/60 Hz 120VAC 0.10 0.37 240V AC 50/60 Hz 0.10 0.20 125V DC 0.10 0.40 125V DC 0.10 0.21 250V DC 0.02 0.20 250V DC 0.02 0.10 Speaker/Amplifier with Voice Capability - Four Input/Output Central Tone Generator with Microphone Paging 5531MV-24N5 120V AC 50/60 Hz 24VDC 0.10 0.36 5540MP-24Y6 120V AC 50/60 Hz 24VDC 0.10 0.32 5531MV-120N5 120V AC 50/60 Hz 120VAC 0.10 0.38 240V AC 50/60 Hz — 0.10 0.20 5531MV-24Y6 120V AC 50/60 Hz 24VDC 0.10 0.32 125V DC — 0.10 0.21 240V AC 50/60 Hz 0.10 0.20 250V DC — 0.02 0.10 125V DC 0.10 0.21 250V DC 0.02 0.10 Speaker/Amplifier - Division 1 Speaker/Amplifier 5545B-AQ 24V-36V DC — 0.061 0.470 24V AC 50/60 Hz — 0.250 1.320 5532M-AQ 24V DC — 0.10 0.74 5545B-Y6 120V AC 50/60 Hz — 0.088 0.260 24V AC 50/60 Hz — 0.10 1.3 240V AC 50/60 Hz — 0.091 0.190 5532M-N5 120V AC 50/60 Hz — 0.10 0.36 125V DC — 0.031 0.130 5532M-Y6 120V AC 50/60 Hz — 0.10 0.32 250V DC — 0.091 0.070 240V AC 50/60 Hz — 0.10 0.20 *Diode polarized model 125V DC — 0.10 0.21 250V DC — 0.02 0.10 Speaker/Amplifier - High Volume HOW TO ORDER ADAPTATONE MILLENNIUM 5532MHV-AQ 24V DC — 0.10 1.5 24V AC 50/60 Hz — 0.10 2.3 Cat. no. + special code Ð input card voltage + power supply voltage 5532MHV-Y6 120V AC 50/60 Hz — 0.10 0.56 240V AC 50/60 Hz — 0.10 0.34 Example: 5531MV-24N5 125V DC — 0.10 0.39 250V DC — 0.10 0.19 CAT. NO. +–+ Speaker/Amplifier - Division 1 - Two Input/Output 5533B-AQ 24V DC — 0.061 0.470 Series Cat. No. Special Code Input Card Power Supply Voltage Voltage 36V DC — 0.077 0.600 5530M = 1 input 24V AC 50/60 Hz — 0.250 1.320 5531M = 4 input AW = 20-31VDC HV= High volume 5533B-Y6 120V AC 50/60 Hz — 0.088 0.260 5532M = Speaker/amp. AQ = 24VAC V = Voice 24 = 24VDC 240V AC 50/60 Hz — 0.091 0.190 5536M = 1 system input N5 = 120VAC P = Pager interface 125V DC — 0.031 0.130 & 3 local inputs 120 = 120VDC Y6 = 120VAC - D = Diode polarized 250V DC — 0.019 0.070 5540M = Tone generator 240VAC 5542 = Remote paging 125VDC - 5533BD-GR* 24V DC — 0.061 0.440 250 VDC 36V DC — 0.077 0.620 5533BD-AW* 20-24 VDC — 0.061 0.440

10 **1065 mil control bro 1/15/02 3:38 PM Page 12

ADAPTATONE MILLENNIUM PRODUCT SPECIFICATIONS

5530M, 5531M, 5531MV, 5532M & 5536M SERIES 5547 SERIES

8 47/64” 8” (222mm) (203mm)

8” (203mm) 4 1/4” Nut to adjust (108mm speaker ) direction

2” Mounting 6” 13 3/4” 2 1/2” (51mm) (152mm) (64mm) flange (349mm) 4 holes (2 each side) 4 1/4” 6” (108mm) 3 1/2” 1/2” (13mm) (152mm) (89mm) conduit mounting 8” Total depth of speaker - 3 1/4” (83mm) (203mm)

5530MHV, 5531MHV, 5532MHV & 5536MHV SERIES 5551 SERIES

11 1/2” 9 3/4” (292mm) (248mm) One of two 9 3/4” #8-32 x 1 1/2” (248mm) (38mm) screws

Nut to adjust speaker direction 8” (203mm)

Mounting 2” 6” 15” 2 1/2” flange (51mm) (152mm) (381mm) (64mm) 4 holes (2 each side) 2 1/2” 6” (64mm) 3 1/2” 1/2” (13mm) (152mm) (89mm) conduit mounting 8” (203mm)

5540M, 5540MV, 5540MP & 5535 SERIES 5538 SERIES (5535 mounts internally - no external flange)

4 1/8” Mounting flange 8” (105mm) 4 holes (2 each side) (203mm)

2 1/8” 2” 6” 2 1/2” (54mm) (51mm) (152mm) (64mm)

6” 1/2” (13mm) (152mm) 4 1/2” 3 1/2” (114mm) (89mm) conduit mounting

5533 & 5545 SERIES SYSTEM MASTER

Horn pivots one way 180˚

11 1/4" (286mm)

11 1/4" (286mm) 18 3/8" (467mm)

To hear all 27 programmable tones available visit our website at www.edwards-signals.com 11 **1065 mil control bro 1/15/02 3:35 PM Page 1

90 Fieldstone Court Cheshire, CT 06410-1212 Phone: (203) 699-3300 Fax: (203) 699-3108 email: [email protected]

© 2002 Edwards Signaling www.edwards-signals.com #XXXX/Xm/X-XX