E-FILE STAMP HOLY CROSS

SCHOOL DRIVE CLOISTER SITE

ENGINEERS PLANNERS LANDSCAPE ARCHITECTS SURVEYORS VIKA , LLC 20251 CENTURY BOULEVARD SUITE #400 GERMANTOWN, MARYLAND 20874 PHONE: (301) 916-4100 FAX: (301) 916-2262 GERMANTOWN, MD. TYSONS, VA.

PREPARED FOR: TUCKERMAN LANE STRATHMORE FIVESQUARES DEVELOPMENT @ GROSVENOR METRO, LLC 1 THOMAS CIRCLE, NW SUITE 200 WASHINGTON, DC, 20005 PARK CONDOS 202-640-4445 VICINITY MAP SYLKE KNUPPEL, PE SCALE: 1" = 2,000' DESIGN CONSULTANTS ARCHITECT Existing Pathway Removal of two existing gates and PERKINS EASTMAN DC & Stairs to 1 THOMAS CIRCLE, NW

25'R apurtenances and concrete pavement remain and reconfiguration of pavement and SUITE 270 curb for new exit WASHINGTON, DC 20005 Knox Box mounted on 202.495.7430 Bollard for Fire MATT BELL 13'R Department use Limits of new paving, Typ. LANDSCAPE ARCHITECT 31.8' 3 Removable VIKA MARYLAND, LLC Existing Delineator posts, Typ. locked bollards 20251 CENTURY BOULEVARD 20' for Fire access SUITE 400 19.8' 44.7' turnaround GERMANTOWN, MD 20874 30'R Existing Existing Pavement marking THE MUSIC to match and to tie Pavement Fixed bollards, Typ. 301.916.4100 11.9' into existing STRATHMORE JOSH SLOAN Existing marking, Typ. PARK COURT CENTER AT 25'R 15'R 20'R 15'R 20.0 25'R ATTORNEY

STRATHMORE 20' LERCH, EARLY, BREWER 7600 60.0' 25'R SUITE 700 25'R BETHESDA, MD 20814 Pavement 301.986.1300 Additional Exit STEVE ROBINS 20' marking, Typ. 6' 10' Saw cut pavement and retain shaded area as TRAFFIC ENGINEER MBF-4 Area Way 60.0' pathway for pedestrian access to Metro Station WELLS + ASSOCIATES and for Fire access turnaround Existing SWM 1420 SPRING HILL ROAD Facility to remain SUITE 610 TYSONS, VA 22102 703.917.6620 CHRIS TURNBULL TUCKERMAN LANE MBF-3 PLANNING, CIVIL ENGINEERING 10' 10' PUE - PLATVIKA 21567 MARYLAND, LLC 20251 CENTURY BOULEVARD 26.2' MERIDIAN AT SUITE 400 Existing GERMANTOWN, MD 20874 GROSVENOR 301.916.4100

Garage Expansion LAURENT MOUNAUD, PE

Existing surface park & ride to be STATION removed and returned to permanent stabilization condition (grass) REVISIONS DATE 1 INITIAL SUBMISSION 4/25/2018 25'R Tie into existing curb & gutter

Concrete walkway for Artswalk Existing Totems relocated, (Total of 32) 25'R

Area Way 10' STRATHMORE MBF-1 HALL STREET Garage Expansion Above Grade 12.0' 12.0'

3 20.0' 3 HC HC HC HC Limits of New 26.0' 2 2 2 1 2 SHARE SHARE SHARE 9.0' SHARE 10' Paving, Typ. 4 4 2 17.0' 8.0' Existing Kiss & Ride Area Relocated 17.0' 17.0' PROFESSIONAL SEAL 17.0' to be removed Light, Typ. 9.0' MC MC MC MC MC MC MC MC MC MC MC MC MC 18.0' 19 MC 9.0' 15.0' 18.0' 16 10 15.0' Tie into existing 15.0' 17' sidewalk Kiss & Ride 17.0' 8.0'3 TAXI 22.0' TAXI 5 TAXI TAXI TAXI 6.6' SHUTTLE DROP-OFF 3 6.5' LOADING ZONE MBF-2 15.0' 15.0' 2.0' Relocated 8.0' 4' Chainlink Existing Metro bus dropoff to remain 5.0' 3.0' Light, Typ. Fence 4' Chainlink Relocated 24.7' AVALON AT Fence Light, Typ. Storage Bike Station GROSVENOR

I HEREBY CERTIFY THAT THESE DOCUMENTS WERE Shed STATION PREPARED OR APPROVED BY ME, AND THAT I AM A Reconfigured DULY LICENSED PROFESSIONAL ENGINEER UNDER Storage Area THE LAWS OF THE STATE OF MARYLAND. NAME: LAURENT MOUNAUD LICENSE #: 36749 EXPIRATION DATE:JAN. 21, 2019 GROSVENOR -

10' PUE WMATA PL. 21568 NORTH BOUND TRACKS STRATHMORE GROSVENOR - STRATHMORE STATION WMATA GARAGE EXPANSION SOUTH BOUND TACKS 4TH ELECTION DISTRICT MONTGOMERY COUNTY, MARYLAND WSSC GRID: 213NW05 TAX MAP:HP123 ROCKVILLE PIKE - MANDATORY PLAN LEGEND REFERRAL PROPERTY LINES PROPOSED WATER LINE EXISTING GUY POLE EXISTING BOLLARD PROPOSED REMOVABLE LOCKED BOLLARD EXISTING CABLE TELEVISION CONDUIT EXISTING GAS VALVE EXISTING SIGN POST PROPOSED SANITARY SEWER PROPOSED FIXED BOLLARD SITE EXISTING ELECTRICAL CONDUIT EXISTING WOOD POST WITH STRUCTURE EXISTING LIGHT POLE PROPOSED DELINEATOR POST EXISTING EDGE OF PAVEMENT EXISTING PHONE PEDESTAL EXISTING INLETS PROPOSED CROSSWALK EXISTING FENCE LINE PROPOSED STORM DRAIN PLAN EXISTING PHONE MANHOLE EXISTING CURB INLET PROPOSED RELOCATED LIGHTS EXISTING NATURAL GAS CONDUIT PROPOSED LIMITS OF DISTURBANCE EXISTING UTILITY POLE EXISTING CONCRETE 3 DRAWN BY: LWA EXISTING OVERHEAD WIRES PROPOSED PARKING LABELS PROPOSED STORM WATER EASEMENT EXISTING SANITARY MANHOLE EXISTING CURB AND GUTTER DESIGNED BY: IPD/LGM EXISTING TELEPHONE CONDUIT PROPOSED HARDSCAPE EXISTING CROSSWALK EXISTING TRAFFIC CONTROL BOX EXISTING BUILDING DATE ISSUED: 04/25/18 EXISTING PUBLIC UTILITIES EASEMENTS EXISTING STORY EXISTING SANITARY CLEANOUT EXISTING TRAFFIC SIGNAL POLE DOOR LOCATION EXISTING SANITARY SEWER CONDUIT EXISTING ELECTRICAL TRANSFORMER 0 25' 50' 100' EXISTING STORM DRAIN MANHOLE EXISTING TREE VIKA EXISTING STORM DRAIN CONDUIT EXISTING ASPHALT PROJECT VM 50226 A EXISTING ELECTRICAL JUNCTION BOX EXISTING CABLE TELEVISION PEDESTAL PROPOSED SWM FACILITY EXISTING WATER CONDUIT EXISTING EASEMENT SCALE: 1" = 50' EXISTING ELECTRICAL MANHOLE EXISTING UNKNOWN UTILITY MANHOLE APPLICATION EXISTING ZONE LIMITS EXISTING REINFORCED CONCRETE PIPE PROPOSED SWM FACILITY WITH NO. PROPOSED 10' CONTOUR EXISTING FIRE DEPARTMENT CONNECTION EXISTING WATER METER EXISTING CORRUGATED METAL PIPE CHEEK WALL AND CURB CUT MR2018026 PROPOSED 2' CONTOUR EXISTING FIRE HYDRANT EXISTING WATER MANHOLE EXISTING BUILDING RESTRICTION LINE PROPOSED GARAGE AREA-WAYS PROPOSED 1' CONTOUR EXISTING GAS MANHOLE EXISTING WATER VALVE EXISTING RIGHT-OF-WAY SHEET NO. MRPLAN-003