Ipv6-Security Monitoring
Total Page:16
File Type:pdf, Size:1020Kb
Load more
Recommended publications
-
Ngenius Collector Appliance Scalable, High-Capacity Appliance for Collection of Cisco Netflow and Other Flow Data
l DATA SHEET l nGenius Collector Appliance Scalable, High-Capacity Appliance for Collection of Cisco NetFlow and Other Flow Data Product Overview HIGHLIGHTS Deployed at key traffic aggregation locations, nGenius® Collectors extend the reach of the nGeniusONE® Service Assurance solution and are used primarily to generate flow‑based • Measure service responsiveness across statistics (metadata) in memory for specific traffic types. This NETSCOUT data source collects the network with up to 500 Cisco IP SLA metadata on IP SLA and IPPING protocols, flow data from NetFlow routers, link‑level statistics, synthetic transaction tests and utilization data from MIB‑II routers. • Scalable collection of up to 2 million Cisco NetFlow, IPFIX, Juniper J-Flow, Huawei® Listening passively on an Ethernet wire, nGenius Collectors examine specific traffic collected NetStream and sFlow flows per minute from flow‑enabled routers and switches (e.g., Cisco® NetFlow, Juniper® J-Flow, sFlow®, ® • Captures and stores Flow datagrams for NetStream ) and from IP SLA test results to generate a variety of statistics. In addition, Collectors historical deep-dive analysis can be configured to capture datagrams from Flow‑enabled routers and analyze them via datagram capture, which allows users to perform in‑depth capture and filtering. • Collects Flow data from up to 5,000 flow‑enabled router or switch interfaces Metrics from nGenius Collectors are retrieved through a managing nGenius for Flows Server per appliance for analysis, enabling display of utilization metrics, quality of service (QoS) breakdowns, and • Supports both IPv4 and IPv6 environments application breakdowns in nGenius for Flows and other tools in the nGeniusONE Service • Purpose-built hardware and virtual Assurance Solution. -
Netflow Traffic Analyzer Real-Time Network Utilization and Bandwidth Monitoring
DATASHEET NetFlow Traffic Analyzer Real-Time Network Utilization and Bandwidth Monitoring An add-on to Network Performance Monitor (NPM), SolarWinds® NetFlow DOWNLOAD FREE TRIAL Traffic Analyzer (NTA) is a multi-vendor flow analysis tool designed to proactively reduce network downtime. NTA delivers actionable insights Fully Functional to help IT pros troubleshoot and optimize spend on bandwidth by better for 30 Days understanding the who, what, and where of traffic consumption. Solve practical operational infrastructure problems with actionable insights and save money with informed network investments. WHY CHOOSE NETFLOW TRAFFIC ANALYZER? • NTA collects and analyzes flow data from multiple vendors, including NetFlow v5 and v9, Juniper® J-Flow™, sFlow®, Huawei® NetStream™, and IPFIX. • NTA alerts you to changes in application traffic or if a device stops sending flow data. • NTA supports advanced application recognition with Cisco® NBAR2. • NTA shows pre- and post-policy CBQoS class maps, so you can optimize your CBQoS policies. • NTA can help you identify malicious or malformed traffic with port 0 monitoring. • NTA includes WLC network traffic analysis so you can see what’s using your wireless bandwidth. • NTA supplements Network Performance Monitor by helping to identify the cause of high bandwidth. Built on the Orion® Platform, NTA provides the ability to purchase and fully integrate with additional network monitoring modules (config management, WAN management, VoIP, device tracking, IP address management), as well as systems, storage, and virtualization management in a single web console. page 1 DATASHEET: NETFLOW TRAFFIC ANALYZER FEATURES New! VMware vSphere Distributed Switch (VDS) Support Comprehensive support for the VMware VDS, providing visibility within the switch fabric to your east-west VM traffic to help IT pros avoid service impacts when moving workloads. -
Netflow Optimizer™
NetFlow Optimizer™ Installation and Administration Guide Version 2.4.7 (Build 2.4.7.0.23) January 2017 © Copyright 2013-2017 NetFlow Logic Corporation. All rights reserved. Patents both issued and pending. Contents Overview ....................................................................................................................................................................... 3 How NetFlow Optimizer Works .................................................................................................................................. 3 How NFO Updater Works .......................................................................................................................................... 3 NetFlow Optimizer Installation Guide ......................................................................................................................... 4 Before You Install NFO ................................................................................................................................................ 4 Pre-Installation Checklist ........................................................................................................................................... 4 Minimum Requirements ............................................................................................................................................. 4 Supported Platforms .............................................................................................................................................. 4 Virtual Hardware -
Which Time Server Option Is Best for Synchronizing Your Clocks
WHICH TIME SERVER OPTION IS BEST FOR SYNCHRONIZING YOUR CLOCKS? Any electronic device that automatically displays REGARDING MASTER the current local time – your clocks, phone, tablet, TIME CONTROLLERS computer and even most TVs – has to pull that time from a time server. AND The time server acts as a messenger of sorts; IP NETWORK CLOCKS it reads the time from a reference clock and distributes that information via a computer network (ETHERNET OR WI-FI) to your device when the device requests it. The time server could be a local network time server or an internet time server. SNTP, or Simple Network Time Protocol, is an internet standard protocol that allows a clock or device to contact a server and get the current time. It’s a simplification of the more robustNTP (Network Time Protocol) and is used in most embedded devices and computers. Once the device receives the current Coordinated Universal Time (UTC), the device applies offsets such as time zone or daylight saving time considerations, as well as the time spent on the network retrieving the time, before displaying the accurate local time. January 2018 AMERICAN TIME WHITE PAPER BY: MAX BLOM When it comes to syncing time for your organization’s clocks, you have 3 options: Let’s take a look at how each of these options work, their pros and cons, and our recommendation. Port 123 is reserved specifically for External Server IP Address NTP/SNTP communication 1 The NIST – the U.S. Department of Commerce’s National Institute of Standards and Technology – is the primary source for synchronizing time systems in the U.S. -
Flow-Tools Tutorial
Flow-tools Tutorial SANOG 6 Bhutan Agenda • Network flows • Cisco / Juniper implementation – NetFlow • Cisco / Juniper Configuration • flow-tools programs overview and examples from Abilene and Ohio- Gigapop Network Flows • Packets or frames that have a common attribute. • Creation and expiration policy – what conditions start and stop a flow. • Counters – packets,bytes,time. • Routing information – AS, network mask, interfaces. Network Flows • Unidirectional or bidirectional. • Bidirectional flows can contain other information such as round trip time, TCP behavior. • Application flows look past the headers to classify packets by their contents. • Aggregated flows – flows of flows. Unidirectional Flow with Source/Destination IP Key % telnet 10.0.0.2 10.0.0.1 login: 10.0.0.2 Active Flows Flow Source IP Destination IP 1 10.0.0.1 10.0.0.2 2 10.0.0.2 10.0.0.1 Unidirectional Flow with Source/Destination IP Key % telnet 10.0.0.2 % ping 10.0.0.2 login: 10.0.0.1 10.0.0.2 ICMP echo reply Active Flows Flow Source IP Destination IP 1 10.0.0.1 10.0.0.2 2 10.0.0.2 10.0.0.1 Unidirectional Flow with IP, Port,Protocol Key % telnet 10.0.0.2 % ping 10.0.0.2 login: 10.0.0.1 10.0.0.2 ICMP echo reply Active Flows Flow Source IP Destination IP prot srcPort dstPort 1 10.0.0.1 10.0.0.2 TCP 32000 23 2 10.0.0.2 10.0.0.1 TCP 23 32000 3 10.0.0.1 10.0.0.2 ICMP 0 0 4 10.0.0.2 10.0.0.1 ICMP 0 0 Bidirectional Flow with IP, Port,Protocol Key % telnet 10.0.0.2 % ping 10.0.0.2 login: 10.0.0.1 10.0.0.2 ICMP echo reply Active Flows Flow Source IP Destination IP prot srcPort -
Endrun TECHNOLOGIES Præcis Cntp Network Time Server
Smarter Timing Solutions EndRun TECHNOLOGIES Præcis Cntp Network Time Server User’s Manual Præcis Cntp Network Time Server User’s Manual EndRun Technologies 1360 North Dutton Avenue #200 Santa Rosa, California USA 95401 Phone 707-573-8633 • Fax 707-573-8619 Preface Thank you for purchasing the Præcis Cntp Network Time Server. Our goal in developing this product is to bring precise, Universal Coordinated Time (UTC) into your network quickly, easily and reliably. Your new Præcis Cntp is fabricated using the highest quality materials and manufacturing processes available today, and will give you years of troublefree service. About EndRun Technologies Founded in 1998 and headquartered in Santa Rosa, California, we are the leaders in the exciting new time and frequency distribution technology based on the Code Division Multiple Access (CDMA) mobile telecommunications infrastructure. Our innovative designs and painstaking attention to the details of efficient manufacturability have made us the first to bring this technology to the broad synchronization market at prices small businesses can afford. EndRun Technologies markets this technology in three major product lines: Network Time Sources/Servers – These units are configured for optimum performance in operation with network servers/networks running the Internet protocol known as the Network Time Protocol (NTP). Instrumentation Time and Frequency References – These products provide UTC traceable time and frequency signals for use in precision test and measurement instrumentation. OEM Time and Frequency Engines – These products provide the core time and frequency capabilities to our customers who require lower cost and tighter integration with their own products. About this manual This manual will guide you through simple installation and set up procedures. -
Brocade Vyatta Network OS Data Sheet
DATA SHEET Brocade Vyatta Network OS HIGHLIGHTS A Network Operating System for the Way Forward • Offers a proven, modern network The Brocade® Vyatta® Network OS lays the foundation for a flexible, easy- operating system that accelerates the adoption of next-generation to-use, and high-performance network services architecture capable of architectures meeting current and future network demands. The operating system was • Creates an open, programmable built from the ground up to deliver robust network functionality that can environment to enhance be deployed virtually or as an appliance, and in concert with solutions differentiation, service quality, and from a large ecosystem of vendors, to address various Software-Defined competitiveness Networking (SDN) and Network Functions Virtualization (NFV) use cases. • Supports a broad ecosystem for With the Brocade Vyatta Network OS, organizations can bridge the gap optimal customization and service between traditional and new architectures, as well as leverage existing monetization investments and maximize operational efficiencies. Moreover, they can • Simplifies and automates network compose and deploy unique, new services that will drive differentiation functions to improve time to service, increase operational efficiency, and and strengthen competitiveness. reduce costs • Delivers breakthrough performance flexibility, performance, and operational and scale to meet the needs of any A Proven, Modern Operating efficiency, helping organizations create deployment System The Brocade Vyatta Network OS new service offerings and value. Since • Provides flexible deployment options separates the control and data planes in 2012, the benefits of this operating to support a wide variety of use cases software to fit seamlessly within modern system have been proven by the Brocade SDN and NFV environments. -
Introduction to Netflow
Introduction to Netflow Campus Network Design & Operations Workshop These materials are licensed under the Creative Commons Attribution-NonCommercial 4.0 International license (http://creativecommons.org/licenses/by-nc/4.0/) Last updated 14th December 2018 Agenda • Netflow – What it is and how it works – Uses and applications • Generating and exporting flow records • Nfdump and NfSen – Architecture – Usage • Lab What is a Network Flow • A set of related packets • Packets that belong to the same transport connection. e.g. – TCP, same src IP, src port, dst IP, dst port – UDP, same src IP, src port, dst IP, dst port – Some tools consider "bidirectional flows", i.e. A->B and B->A as part of the same flow http://en.wikipedia.org/wiki/Traffic_flow_(computer_networking) Simple flows = Packet belonging to flow X = Packet belonging to flow Y Cisco IOS Definition of a Flow • Unidirectional sequence of packets sharing: – Source IP address – Destination IP address – Source port for UDP or TCP, 0 for other protocols – Destination port for UDP or TCP, type and code for ICMP, or 0 for other protocols – IP protocol – Ingress interface (SNMP ifIndex) – IP Type of Service IOS: which of these six packets are in the same flows? Src IP Dst IP Protocol Src Port Dst Port A 1.2.3.4 5.6.7.8 6 (TCP) 4001 22 B 5.6.7.8 1.2.3.4 6 (TCP) 22 4001 C 1.2.3.4 5.6.7.8 6 (TCP) 4002 80 D 1.2.3.4 5.6.7.8 6 (TCP) 4001 80 E 1.2.3.4 8.8.8.8 17 (UDP) 65432 53 F 8.8.8.8 1.2.3.4 17 (UDP) 53 65432 IOS: which of these six packets are in the same flows? Src IP Dst IP Protocol Src Port Dst Port A 1.2.3.4 5.6.7.8 6 (TCP) 4001 22 B 5.6.7.8 1.2.3.4 6 (TCP) 22 4001 C 1.2.3.4 5.6.7.8 6 (TCP) 4002 80 D 1.2.3.4 5.6.7.8 6 (TCP) 4001 80 E 1.2.3.4 8.8.8.8 17 (UDP) 65432 53 F 8.8.8.8 1.2.3.4 17 (UDP) 53 65432 What about packets “C” and “D”? Flow Accounting • A summary of all the packets seen in a flow (so far): – Flow identification: protocol, src/dst IP/port.. -
NBAR2 Standard Protocol Pack 1.0
NBAR2 Standard Protocol Pack 1.0 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 © 2013 Cisco Systems, Inc. All rights reserved. CONTENTS CHAPTER 1 Release Notes for NBAR2 Standard Protocol Pack 1.0 1 CHAPTER 2 BGP 3 BITTORRENT 6 CITRIX 7 DHCP 8 DIRECTCONNECT 9 DNS 10 EDONKEY 11 EGP 12 EIGRP 13 EXCHANGE 14 FASTTRACK 15 FINGER 16 FTP 17 GNUTELLA 18 GOPHER 19 GRE 20 H323 21 HTTP 22 ICMP 23 IMAP 24 IPINIP 25 IPV6-ICMP 26 IRC 27 KAZAA2 28 KERBEROS 29 L2TP 30 NBAR2 Standard Protocol Pack 1.0 iii Contents LDAP 31 MGCP 32 NETBIOS 33 NETSHOW 34 NFS 35 NNTP 36 NOTES 37 NTP 38 OSPF 39 POP3 40 PPTP 41 PRINTER 42 RIP 43 RTCP 44 RTP 45 RTSP 46 SAP 47 SECURE-FTP 48 SECURE-HTTP 49 SECURE-IMAP 50 SECURE-IRC 51 SECURE-LDAP 52 SECURE-NNTP 53 SECURE-POP3 54 SECURE-TELNET 55 SIP 56 SKINNY 57 SKYPE 58 SMTP 59 SNMP 60 SOCKS 61 SQLNET 62 SQLSERVER 63 SSH 64 STREAMWORK 65 NBAR2 Standard Protocol Pack 1.0 iv Contents SUNRPC 66 SYSLOG 67 TELNET 68 TFTP 69 VDOLIVE 70 WINMX 71 NBAR2 Standard Protocol Pack 1.0 v Contents NBAR2 Standard Protocol Pack 1.0 vi CHAPTER 1 Release Notes for NBAR2 Standard Protocol Pack 1.0 NBAR2 Standard Protocol Pack Overview The Network Based Application Recognition (NBAR2) Standard Protocol Pack 1.0 is provided as the base protocol pack with an unlicensed Cisco image on a device. -
Conntrack, Netfilter, Netflow and NAT Under Linux
Xurble conntrack, Netfilter, NetFlow and NAT under Linux Oliver Gorwits 9th February 2010 Milton Keynes Perl Mongers 1 “Policy Compliance” • We have legal obligations • Avoiding the courts ✔ • Avoiding the newspapers ✔ 2 (alleged) Copyright Violations Subject: File-sharing of unauthorised content owned by Twentieth Century Fox From: [email protected] Dear Oxford University: Twentieth Century Fox Film Corporation, located in Los Angeles, and its affiliated companies (collectively, 'Fox') own intellectual property rights, including exclusive rights protected under copyright laws, in many motion pictures, television programs and other audio-visual works, including the motion picture AVATAR (collectively, the 'Fox Titles'). Fox conducted an online check by scanning public networks and discovered that your Oxford University internet account was used to access and distribute an unauthorised copy of AVATAR. By distributing Fox content without Fox's permission, you infringed Fox's copyright. Here is the information Fox obtained from the online check: Timestamp of report: 07 Feb 2010 23:12:44 GMT Title details: Avatar (2009) PROPER TS XviD-MAXSPEED IP address: 163.1.xxx.yyy Port ID: 30854 Protocol used: BitTorrent - L5 Please respond to Fox and identify what steps you have taken to resolve this matter by contacting Fox at [email protected] 3 The Process • So, given: ○Timestamp with Time Zone ○IP address ○TCP port number • We need: ○User’s identity • Usually via: ○Network log-in logs, and DHCP logs 4 Linux network subsystems Kernel conntrack netfilter iptables pietroizzo 5 Network Address/Port Translation O’Reilly 6 State Tracking User Firewall Internet 1 A ✔ 2 B pre-NAT post-NAT • Traditional loggers run two packet captures and correlate the timestamps. -
IBM Z Server Time Protocol Guide
Front cover Draft Document for Review August 3, 2020 1:37 pm SG24-8480-00 IBM Z Server Time Protocol Guide Octavian Lascu Franco Pinto Gatto Gobehi Hans-Peter Eckam Jeremy Koch Martin Söllig Sebastian Zimmermann Steve Guendert Redbooks Draft Document for Review August 3, 2020 7:26 pm 8480edno.fm IBM Redbooks IBM Z Server Time Protocol Guide August 2020 SG24-8480-00 8480edno.fm Draft Document for Review August 3, 2020 7:26 pm Note: Before using this information and the product it supports, read the information in “Notices” on page vii. First Edition (August 2020) This edition applies to IBM Server Time Protocol for IBM Z and covers IBM z15, IBM z14, and IBM z13 server generations. This document was created or updated on August 3, 2020. © Copyright International Business Machines Corporation 2020. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Draft Document for Review August 3, 2020 8:32 pm 8480TOC.fm Contents Notices . vii Trademarks . viii Preface . ix Authors. ix Comments welcome. .x Stay connected to IBM Redbooks . xi Chapter 1. Introduction to Server Time Protocol . 1 1.1 Introduction to time synchronization . 2 1.1.1 Insertion of leap seconds . 2 1.1.2 Time-of-Day (TOD) Clock . 3 1.1.3 Industry requirements . 4 1.1.4 Time synchronization in a Parallel Sysplex. 6 1.2 Overview of Server Time Protocol (STP) . 7 1.3 STP concepts and terminology . 9 1.3.1 STP facility . 9 1.3.2 TOD clock synchronization . -
Encryption Is Futile: Delay Attacks on High-Precision Clock Synchronization 1
R. ANNESSI, J. FABINI, F.IGLESIAS, AND T. ZSEBY: ENCRYPTION IS FUTILE: DELAY ATTACKS ON HIGH-PRECISION CLOCK SYNCHRONIZATION 1 Encryption is Futile: Delay Attacks on High-Precision Clock Synchronization Robert Annessi, Joachim Fabini, Felix Iglesias, and Tanja Zseby Institute of Telecommunications TU Wien, Austria Email: fi[email protected] Abstract—Clock synchronization has become essential to mod- endanger control decisions, and adversely affect the overall ern societies since many critical infrastructures depend on a functionality of a wide range of (critical) services that depend precise notion of time. This paper analyzes security aspects on accurate time. of high-precision clock synchronization protocols, particularly their alleged protection against delay attacks when clock syn- In recent years, security of clock synchronization received chronization traffic is encrypted using standard network security increased attention as various attacks on clock synchronization protocols such as IPsec, MACsec, or TLS. We use the Precision protocols (and countermeasures) were proposed. For this Time Protocol (PTP), the most widely used protocol for high- reason, clock synchronization protocols need to be secured precision clock synchronization, to demonstrate that statistical whenever used outside of fully trusted network environments. traffic analysis can identify properties that support selective message delay attacks even for encrypted traffic. We furthermore Clock synchronization protocols are specifically susceptible to identify a fundamental conflict in secure clock synchronization delay attacks since the times when messages are sent and between the need of deterministic traffic to improve precision and received have an actual effect on the receiver’s notion of the need to obfuscate traffic in order to mitigate delay attacks.