Home Design and Planning Guide Please note:

Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation or construction.

2 Table of Contents Elvoron Elevator...... 4 Hoistway Construction ...... 5 Wood Construction ...... 6 Masonry Construction ...... 6 Openings ...... 6 Construction of Pit:...... 7 Pit ...... 7 Overhead Clearance...... 7 Car/ Door & Hoistway ...... 8 Hoistway Door Interlock ...... 8 Standard Door Package ...... 8 Automatic Cab Gate (Optional)...... 8 Door Operator (Optional)...... 8 Upgrade Door Package ...... 8 Hall Door Operator (Optional)...... 8 Premium Door Package ...... 8 Codes regarding residential elevator entrances ...... 9 Hoistway Dimensions - standard door package...... 10 Hoistway Dimensions - upgrade door package...... 12 Hoistway Dimensions - premium door package...... 14 3-Speed Door Details ...... 16 Flush Frame and Door Details ...... 17 Flush Frame Details...... 18 Hydraulic Drive System ...... 19 Hydraulic Drive System - Technical Reference ...... 20 General...... 20 Equipment ...... 20 Controls ...... 20 Safety Features ...... 20 Options ...... 20 Hydraulic Drive System - Machine & Electrical Requirements...... 21 Electrical Disconnects ...... 22 Ventilation Requirements ...... 22 Mains Power Requirements ...... 22 Lighting Power Requirements...... 22 Emergency Battery Lowering...... 22 Emergency Manual Lowering...... 22 Hydraulic Drive System - Machine Room Layout...... 23 In-line Drive System ...... 24 In-line Drive System - Technical Reference ...... 25 General...... 25 Equipment ...... 25 Controls ...... 25 Safety Features ...... 25 Options ...... 25 In-line Drive System - Electrical Controller Box Details & Locations...... 26 Electrical Disconnects ...... 27 Ventilation Requirements ...... 27 Mains Power Requirements ...... 27 Lighting Power Requirements...... 27 Battery Lowering - Optional ...... 27 Battery Backup - Optional ...... 27 Emergency Manual Lowering...... 28 Loading Diagram...... 29

3 Elvoron - Home Elevator The Elvoron is a sophisticated elevating system designed specifically for use in private residences. The system fits within a vertical elevator hoistway connecting the to be serviced. Two different drive systems are available with your elevator, the Hydraulic Drive and the In-line Drive.

This Design Guide is intended to assist architects, contractors, home owners and elevator professionals in planning for the Elvoron Home Elevator installation. We strongly recommend that you contact your local Garaventa Lift representative to discuss and become familiar with the code requirements in your area. It is extremely important for you to know and adhere to all local codes and regulations pertaining to the installation and use of residential .

Hydraulic Drive System Shown

4 Hoistway Construction

The elevator rails are attached to a load bearing All the of the hoistway, especially the supporting using rail brackets. The rail bracket spacing is wall, need to be smooth, square and plumb from the determined during the design phase. The rail brackets bottom of the pit to . This is to allow for the are generally 4’ to 8’ apart, measured vertically, required running clearances. depending on the load capacity, size of cab and travel height. Hoistway construction shown is suitable for both No light is required at the top of the hoistway. A light is the Hydraulic Drive system and the In-line Drive system. required in the pit (see Construction of Pit for details). Please see final elevator shop drawings for actual rail bracket locations and job specific dimensions.

Hydraulic Drive System Shown

Rail Brackets attached to wall - locations indicated on shop drawing

Side View Front View (Accordian Gate Shown)

5 Wood Construction Door Openings

2” x 4” wood studs should be used, 2” x 12”’s laid flat Garaventa Lift recommends that the walls on either side are then fastened between the studs. Consult with of the hoistway entrances be framed and finished after your local Garaventa Lift representative if you plan on the doors and frames have been aligned on site. How- using wood studs larger than 2” x 4”, as this can affect ever a header frame above the door will be required to clearances controlled by code. mount the door in place.

The hoistway dimensions indicate the clear inside During installation the rails system and of the cab finished hoistway. Please ensure you allow for wall are installed, then the doors are aligned to the center- finishing (plywood/drywall) on top of the studs. line of the cab opening.

Masonry Construction

It is not necessary to make the return walls on either side of the doors in concrete. More flexibility in door positioning during the installation can be achieved with wood framing around hoistway entrances.

Wood Blocking Guidelines Rail Bracket in Hoistway

6 Construction of Pit

The pit must be the same width and length as the hoistway, and should have a minimum 4” thick concrete floor. Reactions are indicated on each project’s shop drawings. Pit depths range from 8” to 12” depending on car size, load capacity and car door/gate style.

A pit ladder is required only if the pit depth exceeds 36” (915 mm). Be aware that the addition of a pit ladder may affect the finished hoistway size required.

Pit Lighting

A pit light is required if the lighting is less than 50 lx at the pit floor with the lowest door open. The general contractor can install a light in the hoistway pit or provide a separate 110v receptacle outside the hoistway, within 10’ (3000 mm) of either side of the lowest landing door.

Overhead Clearance

In-Line Drive w/ Controller In-Line Drive Hydraulic outside w/ Controller at 84" Cab Height Drive Hoistway top of Hoistway Standard Door Package 96" (2438 mm) 96" (2438 mm) 108" (2743 mm) Upgrade or Premium Door Package 96" (2438 mm) 96" (2438 mm) 114" (2896 mm)

96" Cab Height Standard Door Package 108" (2743 mm) 108" (2743 mm) 120" (3048 mm) Upgrade or Premium Door Package 108" (2743mm) N/A 108" (2743mm)N/A 120" (3048 N/A mm)

7 Car Gate/Door & Hoistway Doors

Hoistway Door Interlocks Residential solid core doors or steel doors must be Swinging hoistway doors are fitted with an interlock that used as the hoistway doors. The doors are equipped ensures the car can not be moved from a landing unless the with an electrical interlock. This lock prevents the hall door is closed and locked. Doors will not open unless doors from opening when the elevator is not present. the elevator is at the same landing. Recommended door width is 36”. The minimum door thickness is 1-3/4”. Standard Door Package Swinging hall doors must comply with local elevator codes which reference the positioning of doors in The Standard Door Package includes a swinging hall door relation to the elevator hoistway and cab. and an accordion car gate. Swinging hall doors are hung (see drawings on page 9). in special door frames which are substantially flush to the inside of the hoistway wall. Swinging doors and/or frames are available from Garaventa Lift or can be provided by Premium Door Package others. Residential solid core doors or steel doors must be The Premium Door Package includes sliding elevator car used as the hoistway doors. The doors are equipped with doors and tandem sliding elevator hall doors. This option an electrical interlock during installation. This lock prevents is available with both 84” and 96" height cabs. the doors from opening when the elevator is not present. Recommended door width is 36”. The minimum door The car door engages with the hall door as the elevator thickness is 1-3/4”. approaches the landing. Once the elevator has reached Hall doors must comply with local elevator codes which the landing, the automatic sliding elevator doors operate reference the positioning of doors in relation to the in tandem, similar to the familiar sliding door entrances elevator hoistway and cab. for commercial passenger elevators. (see drawings on page 9). Photo-electric obstruction sensors ensure that there are Automatic Cab Gate (Optional) no obstructions as the doors are closing. If an obstruction is sensed while the doors are closing, they will automati- cally re-open. The cab gate(s) can be equipped with a power operator for automatic gate opening and closing when the cab arrives at With the Premium Door Package, there is no need to be a landing or the landing door is opened. concerned with conformance to door clearance codes. Choosing this option guarantees compliance with safety Hall Door Operator (Optional) codes regarding elevator entrance clearances.

Each hall door may be supplied with a power door operator. This feature will open the landing door when the cab arrives at a landing or when the hall station is pressed. The oper- ator is mounted above the door frame and requires extra support or blocking. A separate 110 VAC power supply may be required.

Upgrade Door Package

The Upgrade Door Package uses swinging hall doors (optionally supplied with the elevator) and a 3-speed side sliding elevator car door. Photo-electric obstruction sensors ensure that there are no obstructions as the sliding elevator car door is closing. If an obstruction is sensed while the door is closing, it will automatically re-open.

8 Codes regarding residential elevator entrances

The code requirements governing swinging hallway entrance doors for private residence elevators may differ from jurisdiction to jurisdiction. Check with local authorities or residential elevator contractors to determine the requirements in your area while planning your elevator installation.

In North America, requirements are based on The Safety Code for Elevators and Escalators, ASME A17.1/CSA B44.

Swinging hallway elevator doors are now required to be positioned substantially flush to the inside of the hoistway wall, while opening out. This requires the use of a special door frame. The use of sliding hallway doors, available with the Premium Door Package, eliminates this issue.

Flush swinging door frames are available from Garaventa Lift. These are paint-ready 16 gauge steel door frames which can be ordered with or without door closers or automatic door operators. The flush frames include a certified elevator interlock, three 4-1/2" ball bearing hinges with non-removable pins (brushed stainless steel 26D finish), a flush door pull for the hoistway side of the door (aluminum), and a roller latch & strike (26D). Standard Door Package - Swinging Hall Door with Accordian Gate

Running Clearance: Min 1/2” (12 mm) Max 1-1/2” (38 mm)

Inside face of hoistway (hall) door to inside edge of door sill: Max 3/4” (19 mm)

Inside face of hoistway (hall) door to cab gate: Max 4” (101 mm) Rejects a 4” ball in all locations.

Upgrade Door Package - Swinging Hall Door with Sliding Elevator Car Door

Running Clearance: Min 1/2” (12 mm) Max 1-1/2” (38 mm) Inside face of hoistway (hall) door to inside edge of door sill: Max 3/4” (19 mm) Inside face of hoistway (hall) door to outside face of cab door: Max 4” (101 mm) Measured from leading edge of car door. 9 Dimensions

Standard Door Package - swinging hall door with accordion car gate Style 1 clear cab size hoistway width hoistway length jack centerline entrance centerline 36" x 48" 51" 56-1/4" 30" 30-1/4" 36" x 54" 51" 62-1/4" 33" 30-1/4" 36" x 60" 51" 68-1/4" 36" 30-1/4" 40" x 54" 55" 62-1/4" 33" 34-1/4" 42" x 60" 57" 70-1/4" 36-5/8" 36-1/4" 48" x 60" 63" 70-1/4" 36-5/8" 42-1/4" minimum* 48" 46-1/4" Style 2 clear cab size hoistway width hoistway length jack centerline entrance centerline 36" x 48" 51" 54-3/4" 27-3/8" 30-1/4" 36" x 54" 51" 60-3/4" 30-3/8" 30-1/4" 36" x 60" 51" 66-3/4" 33-3/8" 30-1/4" 40" x 54" 55" 60-3/4" 30-3/8" 34-1/4" 42" x 60" 57" 73-1/2" 36-3/4" 36-1/4" 48" x 60" 63" 73-1/2" 36-3/4" 42-1/4" minimum* 48" 44-3/4" Styles 3 & 4 clear cab size hoistway width hoistway length jack centerline entrance A centerline entrance B centerline 36" x 48" 54-7/8" 56-1/4" 30" 30-1/4" 34-3/4" 36" x 54" 54-7/8" 62-1/4" 33" 30-1/4" 40-3/4" 36" x 60" 54-7/8" 68-1/4" 36" 30-1/4" 46-3/4" 40" x 54" 58-7/8" 62-1/4" 33" 34-1/4" 40-3/4" 42" x 60" 60-7/8" 70-1/4" 36-5/8" 36-1/4" 48-3/4" 48" x 60" 66-7/8" 70-1/4" 36-5/8" 42-1/4" 48-3/4" minimum* 51-7/8" 54-1/4" Style 5 clear cab size hoistway width hoistway length jack centerline entrance centerline 36" x 48" 54-7/8" 54-1/2" 27-1/8" 27-1/8" 36" x 54" 54-7/8" 60-1/4" 30-1/8" 30-1/8" 36" x 60" 54-7/8" 66-1/4" 33-1/8" 33-1/8" 40" x 54" 58-7/8" 60-1/4" 30-1/8" 30-1/8" 42" x 60" 60-7/8" 66-1/4" 33-1/8" 33-1/8" 48" x 60" 66-7/8" 66-1/4" 33-1/8" 33-1/8" minimum* 48-7/8" 48"

Style 1 cars are available with left or right openings.

* Minimum hoistway sizes often require hydraulic drive systems and custom rail spacing. Contact Garaventa Lift for more information.

10 Standard Door Package - swinging hall door with accordion car gate

FINISHED HOISTWAY LENGTH 1" [25]  JACK RUNNING " [298] CLEARANCE 4 3 5" [127] 11 CAB  ENTRANCE STYLE-2 CLEAR FINISHED CAB WIDTH HOISTWAY WIDTH

FINISHED CLEAR FINISHED " [57] 1 HOISTWAY LENGTH 4 CAB LENGTH HOISTWAY LENGTH 2

 JACK  JACK 1" [25] 1" [25] 3" [76] RUNNING RUNNING 3" [76] CLEARANCE CLEARANCE " [298] " [298] 4 3 4 3 5" [126] 5" [126] 11 11 CAB CAB   ENTRANCE A STYLE-3 ENTRANCE A STYLE-4 FINISHED FINISHED CLEAR CLEAR CAB WIDTH CAB WIDTH HOISTWAY WIDTH HOISTWAY WIDTH " [23] " [23] 7 8 7 8 FINISHED HOISTWAY LENGTH

 CAB 1  CAB ENTRANCE B  JACK 22" [63] ENTRANCE B

21" [64] CLEAR 2 " [298] CLEAR 4 3 CAB LENGTH 5" [127] CAB LENGTH 11

STYLE-5 FINISHED

(30" x 42") CLEAR CAB WIDTH HOISTWAY WIDTH " [23] 8 7

 CAB ENTRANCE

CLEAR CAB LENGTH

11 Dimensions

Upgrade Door Package - swinging hall door with sliding elevator car door Style 1 clear cab size hoistway width hoistway length jack centerline entrance centerline 40" x 50" 57-1/4" 62-3/4" 33" 33-1/2" 40" x 54" 57-1/4" 66-3/4" 35" 33-1/2" 42" x 60" 59-1/4" 72-3/4" 38" 35-1/2" 48" x 60" 65-1/4" 72-3/4" 38" 41-1/2" minimum* 57-1/4" 49-3/4" Style 2 clear cab size hoistway width hoistway length jack centerline entrance centerline 40" x 50" 57-1/4" 66" 33" 33-1/2" 40" x 54" 57-1/4" 70" 35" 33-1/2" 42" x 60" 59-1/4" 76" 38" 35-1/2" 48" x 60" 65-1/4" 76" 38" 41-1/2" minimum* 57-1/4" 53" Styles 3 & 4 clear cab size hoistway width hoistway length jack centerline entrance A centerline entrance B centerline 40" x 50" 60-1/2" 62-3/4" 33" 33-1/2" 39" 40" x 54" 60-1/2" 66-3/4" 35" 33-1/2" 43" 42" x 60" 62-1/2" 72-3/4" 38" 35-1/2" 49" 48" x 60" 68-1/2" 72-3/4" 38" 41-1/2" 49" minimum* 60-1/2" 62-3/4" Style 5 clear cab size hoistway width hoistway length jack centerline entrance centerline 40" x 50" 60-1/2" 59-1/2" 29-3/4" 35-3/4" 40" x 54" 60-1/2" 63-1/2" 31-3/4" 39-3/4" 42" x 60" 62-1/2" 69-1/2" 34-3/4" 45-3/4" 48" x 60" 68-1/2" 69-1/2" 34-3/4" 45-3/4" minimum* 54-1/2" 59-1/2"

Style 1 cars are available with left or right openings.

* Minimum hoistway sizes often require hydraulic drive systems and custom rail spacing. Contact Garaventa Lift for more information. Upgrade Door Package - swinging hall door with sliding elevator car door

13 Dimensions

Premium Door Package - sliding elevator hall door with tandem sliding elevator car door Style 1 clear cab size hoistway width hoistway length jack centerline entrance centerline 40" x 50" 57-1/4" 68-1/4" 38-1/2" 33-1/2" 40" x 54" 57-1/4" 72-1/4" 40-1/2" 33-1/2" 42" x 60" 59-1/4" 78-1/4" 43-1/2" 35-1/2" 48" x 60" 65-1/4" 78-1/4" 43-1/2" 41-1/2" minimum* 57-1/4" 55-1/4" Style 2 clear cab size hoistway width hoistway length jack centerline entrance centerline 40" x 50" 57-1/4" 77" 38-1/2" 33-1/2" 40" x 54" 57-1/4" 81" 40-1/2" 33-1/2" 42" x 60" 59-1/4" 87" 43-1/2" 35-1/2" 48" x 60" 65-1/4" 87" 43-1/2" 41-1/2" minimum* 57-1/4" 64" Styles 3 & 4 clear cab size hoistway width hoistway length jack centerline entrance A centerline entrance B centerline 40" x 50" 66" 68-1/4" 38-1/2" 33-1/2" 44-1/2" 40" x 54" 66" 72-1/4" 40-1/2" 33-1/2" 48-1/2" 42" x 60" 68" 78-1/4" 43-1/2" 35-1/2" 54-1/2" 48" x 60" 74" 78-1/4" 43-1/2" 41-1/2" 54-1/2" minimum* 66" 68-1/4" Style 5 clear cab size hoistway width hoistway length jack centerline entrance centerline 40" x 50" 66" 59-1/2" 29-3/4" 35-3/4" 40" x 54" 66" 63-1/2" 31-3/4" 39-3/4" 42" x 60" 68" 69-1/2" 34-3/4" 45-3/4" 48" x 60" 74" 69-1/2" 34-3/4" 45-3/4" minimum* 60" 59-1/2"

Style 1 cars are available with left or right openings.

* Minimum hoistway sizes often require hydraulic drive systems and custom rail spacing. Contact Garaventa Lift for more information.

14 Premium Door Package - sliding elevator hall door with tandem sliding elevator car door

15 3-Speed Door Details

RIGHT HAND DOOR ASSEMBLY IN STANDARD MOUNTING SCHEME SHOWN LEFT HAND IS OPPOSITE

7 DETAIL A 528" [1342] DETAIL A

" [55] 5 1 8 416" [109] " [125] 7 8 4 ± 2 " 7 8 7 [200] FILLED BY OTHERS " [265]

" [265] Gap 7 16 7 16 CLEAR 10 10 OPENING " [390] 3 8 15 4" [100] 4" [100]

CLEAR OPENING HOISTWAY SIDE LANDING SIDE 89" [2260] for 84" HT " [2000] for 84" HT. " [2000] for 84" HT. 4 4 100 3/4" [2560] for 96" HT 3 3 78 78 90 9/16" [2300] for 96" HT. 90 9/16" [2300] for 96" HT. MINIMUM ROUGH OPENING FINISHED FINISHED FLOOR FLOOR LEVEL LEVEL

DETAIL B Line of 5 3

" + 1"/- 3" Anchor point 516" [135] 28" [60] " [345] 1 2 9 5 1 16

[140 + 25/- 76] 4" [6]

~13 Max. Typ. 3 3 44" [120] 15 44" [120] 1216" 13" [330] 1 [328] DETAIL B 12" [40] Typ. FINISHED 5 5 " [135] 16 FLOOR LEVEL 7 3516" [900]

5 4316" [1100]

7 " [33] 1 528" [1342] 4 OVERALL WIDTH 1

HOISTWAY SIDE SEE PLAN VIEW FOR ENTRANCE q " / -0 5 8 " + 5 16

5 STANDARD FEATURES [135 +15 / -0] q 7 FRAMES: SQUARE PROFILE, KNOCKED 3516" [900] GAP FILLED GAP FILLED DOWN CONSTRUCTION BY OTHERS 4" [100] 4" [100] BY OTHERS SILLS: EXTRUDED ALUMINUM 43 5 " [1100] 16 NOTES: 1 472" [1206] DO NOT BUILD WALLS UNTIL DOOR FRAMES AND SILLS ARE IN MINIMUM ROUGH OPENING PLACE LEAVE ROUGH OPENINGS AS SPECIFIED ON PLAN VIEW.

LANDING SIDE DRYWALL AND MASONRY WORK BY OTHERS

MINIMUM TRAVEL BETWEEN ADJACENT LANDINGS ON SAME SIDE OF HOISTWAY IS: 100" [2540] for 84" high cab 112" [2845] for 96" high cab

16 Flush Frame and Door Details Garaventa Flush Residential Frame Specifications: * 36" x 79 5/8" Rebate 4 1/2" NRP BB HINGES 6 PANEL DOOR * (3) 4 1/2" NRP BB Hinges (US26D) STEEL DOOR OPERATOR 5 1/4" * Push Plate (Brushed Aluminum) - Hoistway Side OPERATOR JAMB DEPTH * CBH-345 Flush Pull Handle (Aluminum) - Hoistway Side INTERLOCK TRACK 5/8" DRYWALL 5/8" DRYWALL 2" x 4" 1/2" DRYWALL * Interlock Keeper Mounting Plate (Brushed SS) WOOD * Roller Latch In Door EMERGENCY STUD ACCESS SLOT * Roller Strike Plate * Removable Shipping Sill * NBL-102 Frame Mounting Method (Ø3/8" x 2" Lag Bolts Supplied) INTERLOCK KEEPER * 16 Ga. Frame (5 1/4" Jamb Depth) MOUNTING PLATE * Finish: Galvanneal, Paint Ready 4" x 16" 6" PUSH PLATE 4 7/8"

6 5/8" Door Specifications: (HOISTWAY SIDE) * 18 Ga. 6-Panel Steel Door CBH-345 * 79 1/8" Door Height x 35 3/4" Door Width x 1 3/4" Door Thickness FLUSH PULL 30" 30" * Finish: Galvanneal, Paint Ready (HOISTWAY SIDE) 1 7/8" DUMMY DOOR KNOB 5 1/4" OR LEVER JAMB DEPTH Interlock Selections:

(BY OTHERS) 86" * Honeywell RDI

85 5/8" HEAD JAMB DETAILS

79" * Porta EMDL. 79 1/8" 79 5/8" (SIDE VIEW) DOOR HEIGHT FRAME REBATE CLEAR OPENING OVERALL FRAME HEIGHT ROUGH OPENING HEIGHT Additional Options: * Surface mount door closers. 30" 30" 4 1/8" * Concealed door closers. 3 1/2" 1/2" x 2" * Concealed automatic door operators (surface mount track)

39 15/16" PLYWOOD SPACER

STRIKE PLATE 5/8" DRYWALL Supplied By Others:

1 7/8" * Dummy Door Knob or Lever 2 5/8" WOOD 2" x 4" STUD 10" 10" 5 1/4" 5/8" DRYWALL JAMB DEPTH 1/2" DRYWALL 35 3/4" DOOR WIDTH NBL-102 FRAME MOUNTING NBL-102 FRAME MOUNTING

33 5/8" 3/8" ANCHOR ACCESS HOLES ANCHOR ACCESS HOLES CLEAR OPENING (DOOR AT 90 DEG POSITION) DOOR GAP 1 3/4" 1 1/8"

KEEPER OPENING Left Hand Shown SIDE JAMB DETAILS 1/16" 36" (Right Hand Opposite) (TOP VIEW) FRAME REBATE DOOR SET BACK 43" *** ROUGH OPENING DIMENSIONS FRAME O.D. Garaventa Flush Residential Frame Specifications: ARE CRITICAL TO A GOOD 44 1/8" * 36" x 79 5/8" Rebate 4 1/2" NRP BB HINGES INSTALLATION OF DOOR FRAME*** 6 PANEL DOOR ROUGH OPENING * (3) 4 1/2" NRP BB Hinges (US26D) STEEL DOOR LANDING DOOR MONITOR OPERATOR 5 1/4" * Push Plate (Brushed Aluminum) - Hoistway Side OPERATOR JAMB DEPTH SWING NOMENCLATURE * CBH-345 Flush Pull Handle (Aluminum) - Hoistway Side SAFETY SWITCH 14" INTERLOCK TRACK DOOR MONITOR 5/8" DRYWALL 5/8" DRYWALL 2" x 4" 1/2" DRYWALL HOISTWAY HOISTWAY* Interlock Keeper Mounting Plate (Brushed SS) (Where required by Codes) SAFETY SWITCH WOOD * Roller Latch In Door EMERGENCY STUD * Roller Strike Plate Add one 3/4” clearance hole for switch ACCESS SLOT and two pilot holes for #4 self-tapping

* Removable Shipping Sill 1 3/16" screws (using #44 drill bit). #4 SELF-TAPPING SCREW LEFT RIGHT * NBL-102 Frame Mounting Method (Ø3/8" x 2" Lag Bolts Supplied) HAND HAND 3/4" CLEARANCE HOLE INTERLOCK KEEPER * 16 Ga. Frame (5 1/4" Jamb Depth) STRIKE JAMB 7/8" SCREW PILOT HOLE MOUNTING PLATE * Finish: Galvanneal, Paint Ready 4" x 16" 6" PUSH PLATE Garaventa Flush Residential Frame Specifications: 4 7/8"

6 5/8" Door Specifications: (HOISTWAY SIDE) * 36" x 79 5/8" Rebate * 18 Ga. 6-Panel Steel Door 6 PANEL 4 1/2" NRP BB HINGES DOOR CBH-345 * (3) 4 1/2" NRP BB Hinges (US26D) * 79 1/8" Door Height x 35 3/4" Door Width x 1 3/4" Door Thickness

STEEL DOOR OPERATOR 30" 30" FLUSH5 1/4" PULL * Push Plate (Brushed Aluminum) - Hoistway Side * Finish: Galvanneal, Paint Ready OPERATOR (HOISTWAYJAMB DEPTHSIDE) * CBH-345 Flush Pull Handle 1(Aluminum) 7/8" - Hoistway Side INTERLOCK TRACK 5/8" DRYWALL 5/8" DRYWALL DUMMY DOOR KNOB 2" x 4" 1/2" DRYWALL * Interlock Keeper Mounting Plate5 1/4" (Brushed SS) OR LEVER JAMB DEPTH Interlock Selections: WOOD * Roller Latch In Door EMERGENCY (BY OTHERS) STUD 86" * Honeywell RDI * Roller Strike85 5/8" Plate HEAD JAMB DETAILS

ACCESS SLOT 79" * Porta EMDL. 79 1/8" 79 5/8" * Removable Shipping Sill (SIDE VIEW)

DOOR HEIGHT * NBL-102 Frame Mounting Method (Ø3/8" x 2" Lag Bolts Supplied) FRAME REBATE CLEAR OPENING OVERALL FRAME HEIGHT INTERLOCK KEEPER * 16 Ga. Frame (5 1/4"ROUGH OPENING HEIGHT Jamb Depth) Additional Options: MOUNTING PLATE * Finish: Galvanneal, Paint Ready * Surface mount door closers. 4" x 16" 30" 30" 4 1/8" * Concealed door closers. 6" PUSH PLATE 4 7/8"

6 5/8" Door Specifications: (HOISTWAY SIDE) 3 1/2" 1/2" x 2" * Concealed automatic door operators (surface mount track) 39 15/16" * 18 Ga. 6-Panel Steel Door PLYWOOD SPACER 17 CBH-345 STRIKE PLATE * 79 1/8" Door Height x 35 3/4" Door Width x 1 3/4" Door Thickness5/8" DRYWALL Supplied By Others: FLUSH PULL 30" 30" * Finish: Galvanneal, Paint Ready 1 7/8" * Dummy Door Knob or Lever (HOISTWAY SIDE) 1 7/8" 2 5/8" WOOD 2" x 4" STUD 10" 10" 5 1/4" 5 1/4" DUMMY DOOR KNOB Interlock Selections: OR LEVER JAMB DEPTH 5/8" DRYWALL JAMB DEPTH (BY OTHERS) 86" * Honeywell RDI 1/2" DRYWALL

85 5/8" 35 3/4"HEAD JAMB DETAILS

79" * Porta EMDL. 79 1/8" 79 5/8" DOOR WIDTH (SIDE VIEW) NBL-102 FRAME MOUNTING NBL-102 FRAME MOUNTING 33 5/8" 3/8" ANCHOR ACCESS HOLES

DOOR HEIGHT ANCHOR ACCESS HOLES

FRAME REBATE CLEAR OPENING CLEAR OPENING DOOR GAP OVERALL FRAME HEIGHT ROUGH OPENING HEIGHT (DOOR AT 90 DEG POSITION) Additional Options: 1 3/4" 1 1/8"

KEEPER OPENING Left Hand* Shown Surface mount door closers. 30" 30" SIDE JAMB DETAILS 1/16" 4 1/8" * Concealed door closers. 36" 3 1/2" (Right Hand *Opposite) Concealed automatic door operators (surface(TOP mount VIEW) track) FRAME REBATE 1/2" x 2" 39 15/16" DOOR SET BACK PLYWOOD SPACER 43" *** ROUGH OPENING DIMENSIONS STRIKE PLATE FRAME O.D. 5/8" DRYWALL Supplied By Others: ARE CRITICAL TO A GOOD

44 1/8" 1 7/8" * Dummy Door Knob or Lever 2 5/8" ROUGH OPENING INSTALLATION OF DOOR FRAME*** WOOD 2" x 4" STUD 10" 10" 5 1/4" LANDING DOOR MONITOR 5/8" DRYWALL JAMB DEPTH SWING NOMENCLATURE1/2" DRYWALL SAFETY SWITCH 14" 35 3/4" DOOR MONITOR DOOR WIDTH (Where required by Codes) SAFETY SWITCH NBL-102 FRAME MOUNTINGHOISTWAY NBL-102 FRAME MOUNTINGHOISTWAY

33 5/8" 3/8" ANCHOR ACCESS HOLES ANCHOR ACCESS HOLES CLEAR OPENING Add one 3/4” clearance hole for switch DOOR GAP (DOOR AT 90 DEG POSITION) 1 3/4" 1 1/8" and two pilot holes for #4 self-tapping

KEEPER OPENING Left Hand Shown LEFTSIDE JAMB DETAILSRIGHT screws (using #44 drill bit). 1 3/16" #4 SELF-TAPPING SCREW 1/16" HAND HAND 3/4" CLEARANCE HOLE 36" (Right Hand Opposite) (TOP VIEW) STRIKE JAMB 7/8" SCREW PILOT HOLE FRAME REBATE DOOR SET BACK 43" *** ROUGH OPENING DIMENSIONS FRAME O.D. ARE CRITICAL TO A GOOD 44 1/8" INSTALLATION OF DOOR FRAME*** ROUGH OPENING LANDING DOOR MONITOR

SWING NOMENCLATURE SAFETY SWITCH 14" DOOR MONITOR HOISTWAY HOISTWAY (Where required by Codes) SAFETY SWITCH Add one 3/4” clearance hole for switch and two pilot holes for #4 self-tapping LEFT RIGHT screws (using #44 drill bit). 1 3/16" #4 SELF-TAPPING SCREW HAND HAND 3/4" CLEARANCE HOLE STRIKE JAMB 7/8" SCREW PILOT HOLE Flush Frame Details 5 1/4" Garaventa Flush Residential Frame Specifications: 4 1/2" NRP BB HINGES JAMB DEPTH INTERLOCK * 36" x 79 5/8" Rebate * (3) 4 1/2" NRP BB Hinges (US26D) EMERGENCY * CBH-345 Flush Pull (Aluminum) - Hoistway Side ACCESS SLOT 5/8" DRYWALL 5/8" DRYWALL 2" x 4" 1/2" DRYWALL WOOD * Interlock Keeper Mounting Plate (Brushed SS) STUD * Roller Latch INTERLOCK KEEPER MOUNTING PLATE * Roller Strike Plate * Removable Shipping Sill (11 Ga. Steel Plate) * NBL-102 Frame Mounting Method (Ø3/8" x 2" Lag Bolts Supplied) * 16 Ga. Frame (5 1/4" Jamb Depth) 6" 4 7/8"

30" 30" * Finish: Galvanneal, Paint Ready 6 5/8"

Door Specifications - Supplied by Others:

86" 1 7/8" * 79 1/8" Door Height x 35 3/4" Door Width x 1 3/4" Door Thickness 85 5/8"

79" 5 1/4" 79 5/8" JAMB DEPTH Interlock Selections: FRAME REBATE CLEAR OPENING OVERALL FRAME HEIGHT ROUGH OPENING HEIGHT HEAD JAMB DETAILS * Honeywell RDI (SIDE VIEW) * Porta EMDL. 30" 30"

39 15/16" Additional Options: 4 1/8" STRIKE PLATE * Surface mount door closers. 3 1/2" 1/2" x 2" * Concealed automatic door operators (surface mount track) PLYWOOD SPACER

10" 10" 5/8" DRYWALL 1 7/8" 2 5/8" 35 3/4" WOOD 2" x 4" STUD DOOR WIDTH (BY OTHERS) NBL-102 FRAME MOUNTING 5 1/4" 5/8" DRYWALL 33 5/8" 3/8" ANCHOR ACCESS HOLES JAMB DEPTH CLEAR OPENING 1/2" DRYWALL (DOOR AT 90 DEG POSITION) DOOR GAP NBL-102 FRAME MOUNTING KEEPER OPENING ANCHOR ACCESS HOLES 1/16" 36" 1 3/4" 1 1/8" FRAME REBATE Left Hand Shown DOOR SET BACK 43" (Right Hand Opposite) SIDE JAMB DETAILS FRAME O.D. (TOP VIEW) 44 1/8" ROUGH OPENING *** ROUGH OPENING DIMENSIONS LANDING DOOR MONITOR ARE CRITICAL TO A GOOD

5 1/4" INSTALLATION OF DOORGaraventa FRAME*** Flush Residential Frame Specifications: SAFETY SWITCH 14" DOOR MONITOR 4 1/2" NRP BB HINGES JAMB DEPTH INTERLOCK * 36" x 79 5/8" Rebate (Where required by Codes) SAFETY SWITCH * (3) 4 1/2" NRP BB Hinges (US26D) DOOR SWING NOMENCLATURE Add one 3/4” clearance hole for switch EMERGENCY * CBH-345 Flush Pull (Aluminum) - Hoistway Side ACCESS SLOT and two pilot holes for #4 self-tapping 5/8" DRYWALL 5/8" DRYWALL HOISTWAY 2" x 4" 1/2" DRYWALL HOISTWAY WOOD * Interlock Keeper Mounting Plate (Brushed SS) screws (using #44 drill bit). 1 3/16" #4 SELF-TAPPING SCREW STUD * Roller Latch 3/4" CLEARANCE HOLE INTERLOCK KEEPER STRIKE JAMB 7/8" MOUNTING PLATE * Roller Strike Plate SCREW PILOT HOLE LEFT RIGHT * Removable Shipping Sill (11 Ga. Steel Plate) HAND HAND * NBL-102 Frame Mounting Method (Ø3/8" x 2" Lag Bolts Supplied) * 16 Ga. Frame (5 1/4" Jamb Depth) 6" 4 7/8"

30" 30" * Finish: Galvanneal, Paint Ready 6 5/8"

5 1/4" Garaventa Flush Residential Frame Specifications: Door Specifications - Supplied by Others: 4 1/2" NRP BB HINGES JAMB DEPTH

INTERLOCK * 36" x 79 5/8" Rebate 86" 1 7/8" * 79 1/8" Door Height x 35 3/4" Door Width x 1 3/4" Door Thickness 85 5/8"

* (3) 4 1/2" NRP79" BB Hinges (US26D)5 1/4" 79 5/8" EMERGENCY * CBH-345 Flush Pull (Aluminum) JAMB - Hoistway DEPTH Side ACCESS SLOT Interlock Selections: FRAME REBATE 5/8" DRYWALL 5/8" DRYWALL CLEAR OPENING 2" x 4" 1/2" DRYWALL OVERALL FRAME HEIGHT ROUGH OPENING HEIGHT HEAD JAMB DETAILS WOOD * Interlock Keeper Mounting Plate (Brushed SS) * Honeywell RDI STUD * Roller Latch (SIDE VIEW) * Porta EMDL. INTERLOCK KEEPER 30" 30" MOUNTING PLATE * Roller Strike Plate * Removable Shipping Sill (11 Ga. Steel Plate)

39 15/16" Additional Options: 4 1/8" STRIKE PLATE * NBL-102 Frame Mounting Method (Ø3/8" x 2" Lag Bolts Supplied) * Surface mount door closers. * 16 Ga. Frame (5 1/4" Jamb Depth) 3 1/2" 1/2" x 2" * Concealed automatic door operators (surface mount track) PLYWOOD SPACER 6" 4 7/8" 30" 30"

10" * Finish: Galvanneal,10" Paint Ready 5/8" DRYWALL 6 5/8" 1 7/8" 2 5/8" 35 3/4" Door Specifications - Supplied by Others: WOOD 2" x 4" STUD DOOR WIDTH (BY OTHERS) NBL-102 FRAME MOUNTING 5 1/4" 86" 1 7/8" 18* 79 1/8" Door Height x 35 3/4" Door Width x 1 3/4" Door Thickness5/8" DRYWALL 33 5/8" 3/8" JAMB DEPTH 85 5/8" ANCHOR ACCESS HOLES 1/2" DRYWALL 79" 5 1/4" CLEAR OPENING 79 5/8" JAMB DEPTH(DOOR AT 90 DEG POSITION) DOOR GAP Interlock Selections: NBL-102 FRAME MOUNTING KEEPER OPENING FRAME REBATE CLEAR OPENING OVERALL FRAME HEIGHT ROUGH OPENING HEIGHT HEAD JAMB DETAILS ANCHOR ACCESS HOLES

1/16" * Honeywell RDI (SIDE36" VIEW) Left* Porta Hand EMDL. Shown 1 3/4" 1 1/8" 30" 30" FRAME REBATE DOOR SET BACK 43" (Right Hand Opposite) SIDE JAMB DETAILS FRAME O.D. (TOP VIEW) 39 15/16" Additional Options: 44 1/8" 4 1/8" STRIKE PLATE ROUGH OPENING *** ROUGH* Surface OPENING mount DIMENSIONS door closers. LANDING DOOR MONITOR 3 1/2" 1/2" x 2" ARE CRITICAL* Concealed TO A GOOD automatic door operators (surface mount track) PLYWOOD SPACER INSTALLATION OF DOOR FRAME*** SAFETY SWITCH 14" 10" 10" 5/8" DRYWALL DOOR MONITOR (Where required by Codes) SAFETY SWITCH 1 7/8" 2 5/8" 35 3/4" DOOR SWING NOMENCLATURE WOOD 2" x 4" STUD

5 1/4" Add one 3/4” clearance hole for switch DOOR WIDTH (BY OTHERS) NBL-102 FRAME MOUNTING 5/8" DRYWALL and two pilot holes for #4 self-tapping 33 5/8" 3/8" ANCHOR ACCESS HOLES HOISTWAY JAMB DEPTH HOISTWAY

1/2" DRYWALL 1 3/16" CLEAR OPENING screws (using #44 drill bit). #4 SELF-TAPPING SCREW (DOOR AT 90 DEG POSITION) DOOR GAP 3/4" CLEARANCE HOLE NBL-102 FRAME MOUNTING 7/8" KEEPER OPENING STRIKE JAMB SCREW PILOT HOLE ANCHOR ACCESS HOLES 1/16" LEFT RIGHT 36" 1 3/4" 1 1/8" FRAME REBATE Left Hand Shown HAND HAND DOOR SET BACK 43" (Right Hand Opposite) SIDE JAMB DETAILS FRAME O.D. (TOP VIEW) 44 1/8" ROUGH OPENING *** ROUGH OPENING DIMENSIONS LANDING DOOR MONITOR ARE CRITICAL TO A GOOD

INSTALLATION OF DOOR FRAME*** SAFETY SWITCH 14" DOOR MONITOR (Where required by Codes) SAFETY SWITCH DOOR SWING NOMENCLATURE Add one 3/4” clearance hole for switch and two pilot holes for #4 self-tapping HOISTWAY HOISTWAY screws (using #44 drill bit). 1 3/16" #4 SELF-TAPPING SCREW 3/4" CLEARANCE HOLE 7/8" STRIKE JAMB SCREW PILOT HOLE LEFT RIGHT HAND HAND Hydraulic Drive System

19 Hydraulic Drive System - Technical Reference

General Standard Safety Features

• Capacity - 750 lbs or 1000 lbs optional • Emergency manual lowering • 40 ft. per minute (0.2 m/sec) nominal car speed • Slack/broken cable instantaneous safety device • Up to 6 stops, Maximum 6 landing doors • Upper and lower terminal limit switches and a • Maximum floor total travel of 42’ 6” (12950 mm)’ final limit at top and bottom of travel • Pit depth of 8” (200 mm) is recommended for • Hoistway door interlocks ensure the car does units with standard swing doors. 12” (356 mm) not move unless all hall doors and cab gate(s) pit required for units with automatic sliding car are closed and locked doors • Emergency battery backup light and alarm • Overhead clearance of 96” (2440 mm) from • Certified electrical control system upper landing with standard 84” (2135 mm) cab • Automatic bi-directional leveling (Encoder) height • Minimum distance between floors is 10” (255 mm) Options Equipment • Upgrade Door Package (swinging hall door with • Two speed control valve with soft start and stop a sliding elevator car door) • 1:2 cable hydraulic drive • Premium Door Package (sliding elevator hall • Single stage Hydraulic drive with two 3/8” door with tandem sliding elevator car door) diameter aircraft cables • Pipe rupture valve • Heavy duty cantilever design utilizing 8 lbs per foot • Keyed hall stations steel elevator guide rail system • Recessed telephone box or integrated • Submersible pump and motor assembly for quiet telephone in cab control panel operation • Automatic cab gate operator(s) • Standard power supply is 230 VAC single phase • Automatic hoistway door operator(s) – 60 Hz. Optional 208 VAC three phase • Custom cab sizes • Buffer Springs – required for hoistways with Controls habitable space under the pit • 96” car height • Collective automatic operation with illuminated push buttons Daily Cycles • PLC (Programmable Logic Controller) with backup system for elevator descent, lights, locks The elevator is designed based on the following and gate and/or door operator(s) where daily cycles: equipped • Digital position indicator in cab • Normal 20 • Automatic cab lighting • Heavy 50 • Low oil protection timer circuit • Excessive 75 • Emergency stop / alarm • Max. starts per hour 10

Consult your Sales Representative if there is a chance you may exceed these amounts.

20 Hydraulic Drive System - Machine Room & Electrical Requirements

In order to satisfy code requirements, the hydraulic To save space the electrical control box can be pump unit and fused disconnect switches must be disconnected from the tank. They can be separated up located in a room or area which is lockable. A lockable to 10’ (3048 mm) away. The control box is 23” wide x 6” is acceptable. However, to meet electrical code, deep x 30” high (585 x 155 x 765 mm). The tank for the Service Personnel must have the following clearance in pump and motor is 23” wide x 16 ½” deep x 31” high front of the electrical box: (585 x 420 x 790 mm). You will need 4” (155 mm) above the pump and motor tank for servicing purposes. US - 36” x 36” x 7’ (915 x 915 x 2135mm) Canada - 393/8” x 393/8” x 7’ (1000 x 1000 x 2135mm) Two PVC sleeves, at least 4” (105 mm) in diameter, will be required between the hoistway and the machinery. One for the hydraulic hose and another for the electrical The machine room does not have to be a separate, conduit. This is to enable the installers to make the dedicated room. The machinery could be located connection between the cylinder and the pumping unit. in a or under the , as long as the above The sleeves should enter the hoistway at either corner of requirements are met. The optimum location is at the the support wall. lowest level, adjacent to the hoistway, preferable on the same side as the guide rails. The dimensions of the Please contact your local Garaventa Lift representative pump unit are 23” wide x 16 ½” deep x 59 ¼” high (585 x for specific local code requirements. 420 x 1505 mm).

21 Hydraulic Drive System - Machine Room & Electrical Requirements

Lighting Mains Power Requirements You must provide at least 100 lx lighting over the pumping unit and disconnect switches. The standard motor on the pump unit is 3 HP and it can be ordered to suit either single or three phase power. Electrical Disconnects • 230 VAC Single phase 30 amps In the machine room, you will need to provide two separate • 208 VAC Three phase 20 amps lockable fused disconnects – one 15 amp for lighting and one 30 amp for the pumping unit. Disconnect switches Lighting Power Requirements should be located on the lock jamb side of the machine room door. In accordance to the electrical code, you must • 120 VAC Single phase 15 amps provide a minimum of 36” (915 mm) square in the US and 39 3/8” (1000 mm) square in Canada of working space in front Uninterruptable Power Supply (UPS) of each disconnect switch. In case of a power outage the elevator is provided with The fused disconnect switch rating and fuse rating for the a second power source that allows the car to be lowered lift will be shown on the shop drawings for your project. to the lowest landing. While descending, the car can stop and the passenger can exit the car at any landing At least one GFCI duplex receptacle connected to a along the way. This feature is sometimes referred to as dedicated 15 amp branch circuit must be installed in the “Emergency Battery Lowering”. machine room. Emergency Manual Lowering Ventilation Requirements The elevator can be manually lowered from the release There are no special requirements for ventilation. The valve located on the top of the Control assembly tank. elevator pump unit will generate approximately 3200 BTU per hour under normal operating conditions. Recommended temperature for elevator equipment is 50º – 90º F (15º – 32º C) and 5% – 90% non-condensing. Please contact your local Garaventa Lift representative for possible local code variations.

Electrical Disconnects

22 Hydraulic Drive System - Machine Room & Electrical Requirements

Machine room plan - USA

Machine area & equipment shown for reference only. Actual site conditions will affect size of machine area & location of equipment.

Light switch & GFCI duplex receptacle 36” [914]

230V-1PH 60Hz 30Amp disconnect fused 25A (nom.) c/w auxiliary contact. 36” [914]

120 1PH 60Hz Disconnect fused 15A Controller

Pump Separate power & oil line sleeves to hoistway (by others)

Machine room plan - Canada

Machine area & equipment shown for reference only. Actual site conditions will affect size of machine area & location of equipment.

Light switch & GFCI duplex receptacle 39-3/8” [1000]

230V-1PH 60Hz 30Amp disconnect fused 25A (nom.) c/w auxiliary contact. 39-3/8” [1000]

120 1PH 60Hz Disconnect fused 15A Controller

Pump Separate power & oil line sleeves to hoistway (by others)

Please contact your local Garaventa Lift representative for specific Machine Room Code Requirements.

23 In-line Drive System

24 In-line Drive System - Technical Reference

General Standard Safety Features

• Capacity - 750 lbs, 1000 lbs optional • Emergency manual lowering • 40 feet per minute nominal car speed (0.2 m/sec) • Slack/broken chain instantaneous safety device • Up to 6 stops, Maximum 6 landing doors • Upper and lower terminal limit switches and a final • Maximum floor total travel of 50’ (15240 mm) limit at top and bottom of travel • Pit depth of 8” (200 mm) is recommended for units • Hoistway door interlocks ensure the car does not with standard swing doors. 9-1/4” (235 mm) pit move unless all hall doors and cab gate(s) are closed required for units with automatic side sliding car and locked doors. • Emergency light and alarm • Minimum distance between floors is 10” (255 mm) • Certified electrical control system • Mechanical Overspeed Governor with electronic detection Equipment • Car and Counterweight Over Travel Bumpers • Mechanically integrated fail safe brake system • Variable frequency drive for smooth start and stop • Uninteruptable Power Supply (UPS) ensures the ability • Suspension: Two #60 ANSI Heavy Duty Roller Chains to lower the car and descend to an exit landing, even • Heavy duty cantilever design utilizing 8 lbs per foot in the event of a power outage. steel elevator guide rail system • High Efficiency Helical reduction gear Options • Standard power supply is 230 VAC single phase – 60/50 Hz • Upgrade Door Package (sliding elevator car door, may include swinging hall door or frame) • Premium Door Package (sliding elevator hall door Controls with tandem sliding elevator car door) • Keyed hall stations • Collective automatic operation with illuminated • Automatic cab gate operator(s) push buttons • Automatic hoistway door operator(s) • PLC (Programmable Logic Controller) with backup • Custom cab sizes system for elevator descent, lights, locks and gate • Emergency Battery Back Up and/or door operator(s) where equipped. • 96” Cab height • Digital position indicator in cab • Automatic cab lighting *Daily Cycles • Emergency stop / alarm The elevator is designed based on the following daily cycles: • Normal 20 • Heavy 50 Overhead Clearances • Excessive 75 • Max. starts per hour 10 *Consult your Sales In-Line Drive w/ In-L ine Drive w/ Representative if there is a chance Controller ControllerIn -Line Drive youIn may-Li nexceede Drive these amounts. Hydraulic Hydraulicoutside wo/ uControllertside at w/ Controller at 84" Cab Height 84" Cab Height Drive HoistwayDrive topHoistway of Hoistway top of Hoistway Standard Door PackageStandard Door Package96" (2438 mm) 96"96" (2438 (2438 m mm)m) 96" (1204838" ( 2mm)743 mm) 108" (2743 mm) Upgrade or Premium DoorUpgrad Packagee or Premium96" Door (2438 Package mm) 96"96 (2438" (2438 m mm)m) 96" (1214438" ( 2mm)896 mm) 114" (2896 mm)

96" Cab Height 96" Cab Height Standard Door PackageS tandard Door Package108" (2743 mm) 108"108" ( 2((2743mm)2774343 m mm)m) 108"1120" 2(207" 43(3048(3048mm) mm) m m) 120" (3048 mm) Upgrade or Premium DoUorpgrad Packagee or Premium Door P ackageN/A N/AN/A N/A N/A N/A

25 In-line Drive System - Electrical Control Box

With the In-line Drive the Electrical Control box can be located inside or outside the hoistway. When placed within the hoistway it is mounted on the wall next to the motor at the top of the rail system. Locating the Control box outside of the hoistway provides better access for installation and servicing.

If located inside the hoistway, the electrical control box will require 12” (305mm) of extra overhead clearance, distance from the upper landing level to the ceiling of the hoistway. The electrical control box, if located remotely must be within 50’ (15.2m) of the motor at the top of the hoistway.

Controller located at the top of the hoistway

6”x6”x4” Motorbrake control box

120 VAC 15A Disconnect 20”x18”x10” lighting Main control box Emergency lowering access hatch 230 VAC 15A Disconnect with seperate neutral motor/control Controller located outside the hoistway The Controller generates heat. 230 VAC 15A Disconnect Maintain 3” of clearance all around. 230 VACwith 15A seperate DISCONNECT neutral MOTOR/CONTROL 23”x18”x10” motor/control MainCONTROL control 120120 VAC VAC 15A 15A DISCONNECT Disconnect BOXbox LIGHTINGlighting

6”x6”x4”6”x6”x4” Motorbrake JUNCTION BOX.control MOTORBRAKE box

EmergencyEMERG. LOWERINGlowering accessACCESS hatch

Note: Left hand motor shown

26 Electrical Disconnects Mains Power Requirements

Two separate 15 amp lockable fused disconnects are required • 230 VAC Single phase 15 amps 60/50 Hz and they must be located within reach of the electrical control box. One is for lighting and one will be for the control box. Lighting Power Requirements In accordance with the electrical code, you must provide a minimum of 30” (762 mm) x 36” (914 mm) x 393/8” (1000mm) • 120 VAC Single phase 15 amps in the US and 30” (762 mm) x 393/8” (1000mm) in Canada of working space in front of each disconnect switch and control box. Uninteruptable Power Supply (UPS)

Specific requirements for the fused disconnect switch In case of a power outage the UPS allows the car to be and fuse rating of your elevator will be shown on the shop lowered, making stops at desired floors on its way. A shelf to drawings. mount the UPS unit is included.

Ventilation Requirements UPS Size: 10-1/2” wide x 9” high x 4” deep (267 x 229 x 102 mm) No special requirements needed. The elevator drive unit will Mounting Shelf: 20” x 5” (508 x 127 mm) generate approximately 3200 BTU per hour under normal operating conditions. Recommended temperature for elevator equipment is 50º – 90º F (15º – 32º C) and 5% – 90% non-condensing. Please contact your local Garaventa Lift representative for possible local code variations.

UPS with Mounting Shelf

Battery Backup – Optional

This feature ensures that the elevator continues to operate up and down during a power outage. The self-contained auxiliary power source is housed within a cabinet and can be located up to 15’ (4.5 M) away from the control box. Cabinet Size: 17 ½” wide x 23 ½” tall x 7 ⅝” thick (600 x 445 Electrical Disconnects x 195 mm)

27 Emergency Manual Lowering

The cab can be manually lowered in case of emergency by inserting a handwheel into the end of the motor and turning to lower the cab. The elevator must be turned off either through the electrical disconnect or the home’s main electrical panel before the elevator cab be lowered.

To insert this handwheel a small access door must be located at the upper landing. A white painted access door is supplied, which can be flush mounted in the wall.

Dimensions

• Access door: 5 1/8” x 5 1/8” (130 x 130 mm) • Outside dimensions of the cover plate: 8” x 9 ½” (203 x 240 mm) • Required opening in the wall: 6 ½” x 6 ½” (165 x 165 mm)

Emergency lowering access hatch location

(Standard Cab Height)

5-1/4" (133) 5-1/4" (133)

Ceiling Ceiling

* * 92" (2337 mm) (2337 92" mm) (2337 92" 80" (2032 mm) 80" (2032 mm) minimum door height (typ) door height minimum (typ) door height minimum

Top floor Top floor Rail Rail wall wall

* - 96” (2438 mm) TALL ELEVATOR CABS: THE VERTICAL DIMENSION IS 104” (2642 mm)

Note

• Emergency lowering access hatch locations shown • For elevators with the upper landing door not in the drawing above are suitable for elevators with adjacent to the rail wall, the emergency lowering the upper landing door located adjacent to the rail access hatch must be located on the hoistway wall wall. adjacent to the motor and not beside the upper door.

28 Loading Diagram

The walls of the elevator hoistway can be constructed of wood, poured concrete or concrete block. The wall behind the rails must be load bearing and able to withstand the loads imposed by the elevator. RAIL

SUPPORTS The guide rails are mounted to the wall with steel brackets. RAILS These rail brackets are fastened to the load bearing wall at REFER TO regular intervals. See job-specific shop drawings for locations. JOB-SPECIFIC SHOP DRAWINGS FOR RAIL RC BRACKET SUPPORT LOCATIONS

RAIL SUPPORT WALL

RC

LOAD COUPLE RC MOVES UP AND DOWN AT 40 FEET/ MINUTE PIT FLOOR

RBS RN

Load Description lbf [N]

RBS Reaction due to buffer safety engagement 6643 [29551]

RN Reaction due to normal operation 4343 [19320]

Load imposed during normal or emergency operation maximum RC 920 [4092] pull-out force on rail support

R1 Rail Reaction 460 [2046]

R2 Rail Reaction 94 [420]

29 © Garaventa Lift. As we are continuously improving our products, specifications outlined in this brochure are Garaventa Lift subject to change without notice. T 800 663 6556 (toll free North America) E [email protected] · I www.garaventalift.com Authorized Garaventa Lift Representative 37086-U-DP-EN