HUMIDITY HUMIDITY HW31K | p. 532 HS20K | p. 513 KH2 | p. 509 SRH12 | p. 525 Kele Carries Nine Brands to Meet Your Sensing Needs. Sensing to Meet Your Kele Carries Nine Brands
GEH2 | p. 515 HW30K | p. 530 HUMIDITY HUMIDITY
Products manufactured MODEL/SERIES PAGE in the United States Humidistats HUMIDITY VH7200 Series — 3% Humidistats...... 557 Products that are new to the catalog TDC Series — 5% Duct Mount Humidistat...... 558 TCY-BH Series — 5% Wall Mount Humidistat...... 560 TCI Series — 3% Wall and Duct Proportional Controller...... 562 EE46 — Condensation Monitor...... 564 HC-101, HC-201 — Room and Duct Humidistats...... 566 W43A-14 — Room Humidistat ...... 566
RH Transmitters A/RH1 Series — Automation Components BAS/HVAC RH Transmitters. . . . .497 HMW90 Series — Wall-Mounted Humicap® Humidity and Temperature Transmitter. 499 E31 Series — Multifunction Humidity/Temperature Transmitter...... 501 HF5 Series — 1% Room and Duct Multi-Parameter Humidity and A/RH2 | p. 519 Temperature Transmitter...... 503 EE23 Series — Room or Duct Humidity, Temperature, Dew Point Transmitter...... 505 HT829, HT839 — 1% and 2% Wall, Duct and OSA Humidity Transmitters. . . . 507 H_20K Series — 2% Wall, Duct and OSA Humidity Transmitters...... 511 HS20K Series — 2% Room Humidity Transmitter ...... 513 GEH2 Series — 2% Wall, Duct and OSA Humidity Transmitters ...... 515 HMD60, HMD70, and HMK41K — 2% Duct and OSA Humidity Transmitters...... 517 A/RH2 Series — 2% Wall, Duct and OSA Humidity Transmitters...... 519 HT2D, HT2O, HT2S — 2% Wall, Duct and OSA Humidity Transmitters. . . . .521 BA/H200 Series — 2% Wall, Duct and OSA Humidity Transmitters...... 523 HS20K | p. 513 SRH12 Series — 2% Wall, Duct and OSA Humidity Transmitters ...... 525 EHRH — 2% Waterproof / Washdown Humidity Transmitter...... 527 KH3 Series — 3% Room, Duct, and OSA Humidity Transmitters...... 528 H_30K Series — 3% Wall, Duct and OSA Humidity Transmitters...... 530 HD31K, HO31K, HW31K — 3% Humidity Transmitter & Optional Temperature Transmitters...... 532 HMW80 Series — 3% Room Humidity and Temperature Transmitter ...... 534 HMD42, HMD53 — 3% Duct Humidity and Temperature Transmitter ...... 536 A/RH3 Series — 3% Room, Duct, and OSA Humidity Transmitters...... 538 BA/H300 Series — 3% Room, Duct, and OSA Humidity Transmitters...... 540 SRH13 Series — 3%Room, Duct, and OSA Humidity Transmitters...... 542 SRH | p. 525 GEH3 Series — 3% Room, Duct and OSA Humidity Transmitters...... 543 KH5 Series — 5% Room, Duct, and OSA Humidity Transmitters...... 545 GEH5 Series — 5% Room, Duct, and OSA Humidity Transmitters ...... 547 A/RH5 Series — 5% Room, Duct, and OSA Humidity Transmitters...... 549 SRH15 Series — 5% Room, Duct, and OSA Humidity Transmitters ...... 551
Specialty Transmitters KH2 Series — 2% Wall, Duct and OSA Humidity Transmitters...... 509 DP4A, EN4A, WB4A — Dew Point, Enthalpy & Wet Bulb Transmitters . . . . .552 HMD/S/W8XD/H/W Series — Dew Point, Enthalpy and Wet Bulb Transmitters...... 554 9002 — Infrared Dew Point & Grains Transmitter...... 555 kele.com A21 — Outdoor Aspirated Humidity / Temperature Housing...... 567 HUMIDITY AUTOMATION COMPONENTS BAS/HVAC RH TRANSMITTERS A/RH1 SERIES
DESCRIPTION Model A/RH1 Relative Humidity Transmitters provide RH readings at ±1% accuracy using a ceramic resistive sensor offering a 20% to 90% operating range . The transmitters come in wall, duct, and OSA mounting styles . They have multiple field-selectable outputs, including 4-20 mA, 0-10V, and 0-5V signals . The supply power is also selectable as 24 VDC or 24 VAC . A/RH1-O A/RH1-R FEATURES • Accuracy of ±1% • Duct and OSA twist-off weatherproof housing • 24 VDC or 24 VAC power (field-selectable) A/RH1-SP • 4-20 mA, 0-10V, or 0-5V signal (field-selectable) • Field-calibratable • Optional temperature sensor A/RH1-D
9
SPECIFICATIONS Supply Voltage 12-40 VDC or 24 VAC, selectable Dimensions Accuracy ±1% @ 77°F (25°C) over a Room 3 8"H. x 2 .8"W x 0 .9"D selectable 20% span from 50 to 70%, (9 .8 x 7 x 2 3. cm) 60 to 80%, or 70 to 90% RH Duct 3 6". (9 cm) Ø head with 8 .15"L
Thermal Effect <0 .005% per °F (<0 .01 per °C) (20 cm) probe 0 .75” (1 .9 cm) Ø HUMIDITY Signal Output 4-20 mA, 0-5 VDC, 0-10 VDC OSA 3 6". (9 cm) Ø head with 3 .0"L (field selectable) (7 .6 cm) probe 1 .4" (3 .6 cm) Ø Measurement Range 0% to 100% Weight Sensing Technology Capacitive Room 0 .22 lb (0 1. kg) Operating Temperature Duct 1 .2 lb (0 .54 kg) Room 32° to 122°F (0° to 50°C) OSA 0 .6 lb (0 .27 kg) Duct/OSA -40° to 140°F (-40° to 60°C) Wall Pack 0 .22 lb (0 1. kg) Enclosure Approvals CE, RoHS Room Plastic Delta-style Warranty 5 years Duct/OSA Plastic weatherproof
WIRING
Output Selection Switches (SW 1) 2 Wire Current Output Signal Output Selection Switches (SW 1) 2 Wire Current Output Signal 4-20 mA Output DC Supply Voltage 4-20 mA Output ON ON DC Supply Voltage 4-20 mA Output ON ON OFF 4-20 mA Output 4-20mA VIN COM VOUT 0-10 VDC Output 3 Wire Current Output Signal OFF ON ON Supply4-20mA Ground VIN COM/ Signal VOUT Common 0-10 VDC Output OFF AC or DC Supply Voltage 3 Wire Current Output 4-20Signal mA Output ON ON 0-5 VDC Output ONSupplyON Ground / Signal Common AC or DC Supply Voltage 4-20mA VIN COM VOUT OFF OFF 4-20 mA Output Voltage Output Signal 0-5 VDC Output 0-10 or 0-5 VDC Output Signal ON ON Supply Ground / Signal Common AC or DC Supply Voltage 4-20mA VIN COM VOUT OFF Voltage Output Signal 4-20mA VIN COM VOUT 0-10 or 0-5 VDC Output Signal Supply Ground / Signal Common March 2014 AC or DCWE Supply MAKE Voltag ITe EASY. kele.com 888-397-5353 USA 497
4-20mA VIN COM VOUT HUMIDITY AUTOMATION COMPONENTS BAS/HVAC RH TRANSMITTERS A/RH1 SERIES
DIMENSIONS
4.68 (11.9) 3.84 4.24 (10.8) 0.75 2.25 3.60 (9.1) 3.95 (10.0) (1.9) in (5.7) 0.89 (9.8) (cm) (2.3) 2.69 0.79 (6.8) (2.0) 2.25 0.86 (5.7) (2.2) 1.00 (2.5) 6.10 (4) PG11/0.5" (1.27) NPT Knockouts 3.84 4.51 (15.5) (9.8) (11.5) 3.00 (7.6)
0.60 PG11 Watertight Fitting (1.5) 1.40 (3.6) (Cable Dia. 0.12 to 0.28"/ 2.75 0.92 0.3 to 0.7 cm) (7.0) (2.3)
Room Outside
0.65 (1.7) 0.75 (1.9) 80 Micron Sintered 2.75 (7.0) Stainless Steel Filter 1.40 Plastic (3.6) Washer 80 Micron 1.07 Stainless 0.75 9 (2.7) Steel (1.9) Sintered FIlter 4.5 (1.4) 1.00 0.58 (2.5) 7.15 (1.5) (18.2) 2.70 0.18 (6.9) (0.5) O.D. Ref 0.46 (1.2) Plastic Cover for Stainless Steel Filter to 2.25 Stainless Protect Sensor during (5.7) Plate Wash Down
0.75 (1.9) Duct Stainless Plate
HUMIDITY ORDERING INFORMATION
MODEL DESCRIPTION A/RH1 1% accuracy humidity transmitter (5070) 20% Range 50 to 70% (6080) 20% Range 60 to 80% (7090) 20% Range 70 to 90% AN Type III 10,000Ω thermistor CP Type II 10,000Ω thermistor 20K 20,000Ω thermistor 100 100Ω 385 PT RTD IK 1,000Ω 385 PT RTD R Room D Duct O Outside air SP Wall plate
A/RH1 - (5070) - AN - R Example: A/RH1- (5070) - AN-R Room humidity transmitter with 1% accuracy over 50 to 70% range and Type III 10,000Ω thermistor
RELATED PRODUCTS PAGE DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995 DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 691-K0A Control transformer, 120:24 VAC, 40 VA, Class 2 979
498 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY WALL-MOUNTED HUMICAP® HUMIDITY AND TEMPERATURE TRANSMITTER HMW90 SERIES
DESCRIPTION The Wall-Mounted Vaisala HMW90 Series HUMICAP® Humidity and Temperature Transmitters measure the relative humidity and temperature of indoor environments, where high accuracy, stability, and reliable operation are required . The HMW90 Series includes models for both current and voltage output . These flexible transmitters offer a variety of options and features . Transmitters are available with an optional display . The HMW90 Series humidity transmitters are quick and easy to install . The wiring is connected secured to the wall through the back plate and the electronics with the sensors can then be easily snapped on . Dip switches for transmitter configuration can be accessed when the HMW90 enclosure is open . Series FEATURES • Easy installation, configuration and field adjustment APPLICATION • ±1.7% accuracy • Museums and archive facilities • Data centers • Optional relay (HMW93 only) • Production and warehouse • Laboratories • NIST calibration certificate included • facilities • Testing environments • Long term stability with HUMICAP® 180R sensor
SPECIFICATIONS 9 Accuracy ±1 .7% RH @ 50° to 104°F Impedance VDC (10° to 40°C) from 0 to 90% RH HMW93 10 kΩ minimum Stability ±0 .5% RH/year Measurement Range 0 to 100% RH, 23° to 131°F Supply Voltage (-5° to 55°C) HMW92 10 to 28 VDC Sensing Technology HUMICAP® 180R HMW93 18 to 35 VDC, 24 VAC ±20%, Operating Temperature 23° to 131°F (-5° to 55°C) 50/60 Hz Enclosure ABS/PC Signal Output Enclosure Rating IP30, UL-V0 approved HMW92 4-20 mA Wiring Terminations Screw terminals
HMW93 0 to 5 VDC, 0 to 10 VDC Dimensions 5 22"H. X 3 19"W. X 1 .18"D HUMIDITY Maximum Output (13 .27 X 8 .1 X 3 .0 cm) Impedance mA Approvals CE HMW92 500Ω Weight 0 34. lb (0 .16 kg) Minimum Output Warranty 1 year
DIMENSIONS
59.5 29.8 30 Ø 4.4 5 47.5 27 132.7 9 34 33.5
81
30.5
HMW90 Series Dimensions HMW90 Series Mounting Base Dimensions
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 499 HUMIDITY WALL-MOUNTED HUMICAP® HUMIDITY AND TEMPERATURE TRANSMITTER HMW90 SERIES
WIRING
HMW92 Wiring (2 Power Supplies) HMW92 (Three-wire connection)
-T +T -RH +RH + Power supply 10 ... 28 VDC -T +T -RH +RH mA - RL = 0 ... 600 Ω + Power supply + Power supply mA - 10 ... 28 VDC 10 ... 28 VDC mA - mA RL = 0 ... 600 Ω RL = 0 ... 600 Ω
9 HMW93 Wiring HMW93 (Three-wire connection)
Relay -RH+RH -T +T -Vs +Vs Power supply Relay -RH+RH -T +T -Vs +Vs + 18 ... 35 VDC - or 24 VAC ±20% V + Power supply 18 ... 35 VDC RL = 10 kΩ min. V V or 24 VAC ±20% V - max. 50 VDC RL = 10 kΩ min. 500 mA HUMIDITY
ORDERING INFORMATION
MODEL DESCRIPTION HMW92 Humidity and Temperature transmitters with two current outputs HMW92D Humidity and Temperature transmitters with two current outputs, with visible display HMW93 Humidity and Temperature transmitters with two voltage outputs HMW93D Humidity and Temperature transmitters with two voltage outputs, with visible display
RELATED PRODUCTS PAGE HTM10 HMW90 series replacement sensor element DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 691-K0A Control transformer, 120:24 VAC, 40 VA, Class 2 979 DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995
500 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY MULTIFUNCTION HUMIDITY/TEMPERATURE TRANSMITTER E31 SERIES
DESCRIPTION The E+E E31 Series Multifunction Humidity/Temperature Transmitters offer precise measurement of humidity and temperature with field selectable analog outputs for both parameters . The unit can also be ordered with enthalpy, dew point, and wet bulb . Two-point calibration can be performed using push-buttons on the circuit board-no need for dismounting which makes it ideal for regulatory environments . Built-in LEDs indicate transmitter status and errors . An optional display is available for local indication of measured values and minimum and maximum values .
FEATURES • Accuracy of ±1.3% RH • Derived values for dew point, enthalpy, and wet bulb • Simple calibration • Stainless steel sintered filter • Optional display available • Dual output signals • RS232 output WIRING 9
RxD/B- 1
SPECIFICATIONS TxD/A+ 2 Serial data output Accuracy GNDSer 3 4-20 mA + Out2 4 Humidity ±1 .3% RH, <90% RH, 5° to 104°F - (-15° to 40°C) 4-20 mA + Out1 5 Analog output GND 6 Temperature ±0 .27°F (±0 .14°C) ±0 .06 Power Supply GND 7 Supply Voltage 8-35 VDC Supply 12-30VAC V+ 8 0-5/10 VDC: HUMIDITY 8-35 VDC, 40 mA; 12-30 VAC, 1 .0 VA 4- 20 mA: 8-35 VDC, 80 mA; 12-30 VAC, 1 .9 VA DIMENSIONS Signal Output Field selectable: 4-20 mA, 0-20 mA, in (500Ω max load), 0-5 V, or 0-10 V, (cm) 5.3 (13.5) 2.6 Communication Serial interface RS232C (6.7) Measurement Range Humidity 0 to 100% RH Temperature -40° to 120°F (-40° to 48 .9°C) 3.5 (9.0) Sensing Technology Humidity Capacitive Temperature Pt1000Ω RTD, 385 curve Sensor Protection Stainless steel sintered filter Display Type Optional, two line, alphanumeric LCD, English units Plastic enclosure Display Dewpoint -40° to 120°F (-40° to 48 .9°C) 6.4 (16.3) 2.6 Enthalpy 0-64 Btu/lb (0 to 400 kJ/kg) 5.3 (13.5) (6.7) Wetbulb 0° to 100°F (-17 .8° to 37 .8°C) Operating Temperature 3.5 Display: -40° to 140°F (9.0) (-40° to 60°C) No Display -4° to 122°F (-20° to 50°C) Enclosure NEMA 4, IP65 Wiring Terminations Screw terminals Warranty 1 year Metal enclosure
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 501 HUMIDITY MULTIFUNCTION HUMIDITY/TEMPERATURE TRANSMITTER E31 SERIES
ORDERING INFORMATION
MODEL DESCRIPTION E31* Humidity and temperature transmitter, 8 to 35 VDC, 12 to 30 VAC HOUSING M Humidity and temperature transmitter with metal housing P Humidity and temperature transmitter with polycarbonate housing APPLICATION A Wall mount B Duct mount D Wall mount with remote sensing probe and 6.6' (2m) cable PROBE LENGTH (MODEL “B” ONLY) 5 Probe length, 7.9" (200 mm) 6 Probe length, 15.8" (400 mm) DISPLAY - No display D LCD display ALARM OUTPUT 9 - No alarm relay S With alarm relay
Chart 1 Chart 2 Chart 3 Physical Parameters 2) Output Signals 3) Scaling (T - temperature, A) - RH 2) - 0 to 5 VDC Td - dew point, Tf - frost point) B) - temperature 3) - 0 to 10 VDC 05 0° to 100° C) - dew point 12 -40° to 120° E) - wet bulb I) - specific enthalpy
Example: E31MA5DS EE31 duct humidity and temperature transmitter with polycarbonate housing, wall HUMIDITY mount, probe length, 7.9", LCD display, with alarm relay.
* Each E31 is shipped with setup software and required cable.
RELATED PRODUCTS PAGE DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995 DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 691-K0A Control transformer, 120:24 VAC, 40 VA, Class 2 979 HA010502 EE23/EE31 Radiation Shield HA011101 1/2" conduit connector
502 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY 1% ROOM AND DUCT MULTI-PARAMETER HUMIDITY AND TEMPERATURE TRANSMITTER HF5 SERIES
DESCRIPTION The Rotronic HF5 Series High Performance Multi Parameter Humidity and Temperature Transmitters are ideal for all applications where exact measurement of humidity, enthalpy, dry bulb, wet bulb, temperatures plus other psychrometric parameters are critical . This high performance transmitter using air chip technology accurately measures relative humidity to within ±0 8%. RH . The HydroClip2 probe can be individually calibrated and adjusted to increase measurement precision where you need it the most . The HF5 Series is available in a duct mount or wall mount configuration . This unit can be factory configured or software HFxxW HF5xxD is available for field configuration .
FEATURES • Interchangeable probe • Calculates all psychrometric values WIRING • Automatic sensor and drift compensation • Optional DIN rail mounting • Field configurable with software 2 T- OUT K2 9 1 V + APPLICATION 2 H-OUT K1 The HF5 is ideal for high accuracy HVAC applications, 1 V + building management systems, museums, libraries, environmental monitoring systems . The HF5 Series measures dew point, wet bulb, enthalpy, specific humidity, absolute humidity and mixing ratio .
Terminals Description HUMIDITY HydroClip2 K2-2: T-OUT Temperature output (+) OUT-2 K2-1: V+ Power supply: 10…28 VDC (+) The new HygroClip2 is available in various formats: from a simple plug-in probe for handheld instruments and data loggers Terminals Description K1-2: H-OUT Relative humidity or dew point (+) OUT-1 to the highly developed cable probes for high temperature and K1-1: V+ Power supply: 10…28 VDC (+) other special applications . As standard, they all have high ac- curacy, which can be increased further by specific adjustments Note: Connect the + of the power supply to only one of the V+ terminals. within our patented AirChip, making every HygroClip2 a high- The two terminals marked V+ are internally connected. end product for all applications .
SPECIFICATIONS Supply Voltage Range HF52 10 to 28 VDC, 40 mA Humidity 0-100% HF53 15 to 40 VDC, 50 mA; 12 to 28 VAC, Temperature -148° to 392°F (-100° to 200°C) 1 .2 VA Display Optional: LCD, 1 or 2 decimals Accuracy ±0 .8% RH @ 73°F (23°C) from Operating Humidity 0 to 100% non-condensing 5% to 95% RH Operating Temperature -40° to 140°F (-40° to 60°C) Stability 0 .5% drift per year Enclosure Rating ABS/IP65 conforms to UL94-HB Repeatability 0 .3% RH Wiring Terminations Screw terminals/ M16 cable gland or Long Term Stability <1% RH/year ½" conduit adapter Response Time RH: Typically 10 seconds for 63 % of Dimensions a jump 35 to 80 %RH Case 5 1"H. x 5 .1"W x 1 .8"D (1 m/sec air flow at sensor) (13 x 13 x 4 .5 cm) Temperature: Typically 4 seconds for 63 % of a Wall Plate 0 6". Ø x 3 .5"L (1 .5 x 9 cm) change from 23 to 80 °C Duct Probe 0 6". Ø x 8 .3"L (1 .5 x 21 cm) (1 m/sec air flow at sensor) Approvals CE/EMC: EMC Directive 2004/108/ Signal Output 4-20 mA EC Maximum Output Weight 1 lb (0 45. kg) Impedance 500Ω Warranty 1 year Minimum Output Impedance 1000Ω
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 503 HUMIDITY 1% ROOM AND DUCT MULTI-PARAMETER HUMIDITY AND TEMPERATURE TRANSMITTER HF5 SERIES
ORDERING INFORMATION
MODEL DESCRIPTION HF520 2-wire (loop powered), 4-20 mA HF532 3-wire, 4-20 mA HF534 3-wire, 0-5 V HF535 3-wire, 0-10 V INSTALLATION/MOUNTING D Duct mount (through wall) W Wall mount PSYCHROMETRIC PARAMETERS B Humidity (0 to 100 %RH) and Temperature - see range below A Temperature & Dew / Frost point - see range below 9 C Temperature & Wet Bulb temperature (Tw) - see range below D Temperature & Enthalpy (H) - see range below OUTPUT RANGES 6X 0° to 100°F (-18° to 38°C) OPTIONAL KEYPAD AND DISPLAY D Keypad and display (HF52: no backlight – HF53: w. backlight) X No keypad and display ELECTRICAL CONNECTION 3 1x ½" conduit adapter (horizontal mounting)
HUMIDITY 4 1x ½" conduit adapter (vertical mounting - type D w/o display) DEWPOINT, WETBULB OR ENTHALPY RANGES (optional) 4X 0° to 100°F (-18° to 38°C) S Hydroclip standard climate probe
HF520 D B 6X D 4 S
Example: HF520DB6XD4S 2 Wire psychrometric transmitter, duct mount, humidity and temperature outputs, display and HydroClip Standard Climate probe.
RELATED PRODUCTS PAGE 691-K0A Control transformer, 120:24 VAC, 40 VA, Class 2 979 DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995 DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994
504 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY ROOM OR DUCT HUMIDITY, TEMPERATURE, DEW POINT TRANSMITTER EE23 SERIES
DESCRIPTION The E+E EE23 series Humidity and Temperature Transmitter has been developed for high-precision measurement of relative humidity and temperature .
EE23 Series transmitters are available for wall and duct mounting with or without the snap inmounting kit, which allows a quick and easy exchange of the transmitter . Outputs can be selected between voltage and current .
A special protection coating for the sensing element permits the permanent use in very polluted environments .
FEATURES • Humidity and temperature calibration • NEMA 4 housing • Stainless steel sintered filter • Optional alarm switch • Optional display APPLICATION 9 • Green houses WIRING • Storage rooms • Swimming halls Output and Supply • Meteorology with active temperature output with passive temperature output
SPECIFICATIONS Accuracy Analog Humidity ±1 .3%, ≤90% RH, 5° to 104°F outputs Analog HUMIDITY (-15° to 40°C) output Temperature ±0 .27°F (±0 .14°C) Hysteresis < 2% RH Supply Voltage 0-5 VDC: 10 .5 - 35 VDC, 35 mA; Alarm Output 12 - 28 VAC, 0 8. VA 0-10 VDC: 15 - 35 VDC, 35 mA; 15 - 28 VAC, 1 4. VA 4-20 mA: 15 to 35 VDC, 60 mA; 15 to 28 VAC, 2 .6 VA Signal Output 4-20 mA, 0-5 VDC, 0-10 VDC Maximum Output DIMENSIONS Impedance 470Ω Minimum Output in Metal: 5.3 (13.5) Impedance 5000Ω (cm) Measurement Range Humdity: 0-100% Sensing Technology Humidity: Capacitive, HC1000-200 3.5 Temperature: 1000Ω Platinum (9.0) (class A, DIN EN 60751) Sensor Protection sintered stainless steel filter Operating Temperature Non-display -40° to 140°F (-40° to 60°C) Plastic: 3.5 (9.0) With display -22° to 140°F (-30° to 60°C) Display LCD, English units Enclosure Polycarbonate or Aluminum alloy 2.6 Enclosure Rating NEMA 4 (IP65) (6.7) Wiring Terminations Screw terminals maximum size wire AWG 16 (1 .5 mm2) Approvals CE Both metal and plastic casings are 2.6" (6.7 cm) deep Warranty 1 year March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 505 HUMIDITY ROOM OR DUCT HUMIDITY, TEMPERATURE, DEW POINT TRANSMITTER EE23 SERIES
ORDERING INFORMATION
MODEL DESCRIPTION EE23 Humidity and temperature transmitter, 8 to 35 VDC, 12 to 30 VAC HOUSING M Humidity and temperature transmitter with metal housing P Humidity and temperature transmitter with polycarbonate housing APPLICATION A Wall mount B Duct mount PROBE LENGTH (MODEL “B” ONLY) 5 Duct probe length, 7.9" (20.0 cm) 6 Duct probe length, 15.8" (40.0 cm) DISPLAY 9 – No display D LCD display ALARM OUTPUT – No alarm relay S With alarm relay AB RH and temperature OUTPUT 2 0-5 VDC 3 0-10 VDC 6 4-20 mA HUMIDITY RANGE FOR TEMPERATURE 05 0° to 100°F (-17° to 37.8°C) 10 -20° to 120°F (-28.9° to 48.9°C) 12 -40° to 120°F (-40° to 48.9°C) 15 20° to 120°F (-6.7° to 48.9°C)
EE23 P B 6X D S AB 2 12
Example: EE223PB6DSAB212 EE23 duct humidity and temperature transmitter with plastic case, 15.8" (40.0 cm) probe, LCD display, 0-5 VDC outputs for RH and temperature (0-100%; -40° to 120°F (-40° to 120°C)
RELATED PRODUCTS PAGE DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995 DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 691-K0A Control transformer, 120:24 VAC, 40 VA, Class 2 979 HA010502 EE23/EE31 Radiation Shield HA010502 1/2" conduit connector
506 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY 1% AND 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS HT829, HT839
DESCRIPTION The Minco Model HT829 Relative Humidity Transmitter measures 0% to 100% RH over a range of -10° to 185°F (-23° to 85°C) . The standard two-wire, 4-20 mA output Room provides low-cost space, duct, and outdoor monitoring Housing or process and industrial building control . A temperature (S) sensor built into the integrated circuit provides temperature compensation over the full temperature range .The HT839 Series has temperature transmitter output .
FEATURES Duct • Temperature-compensated IC sensor Housing • One-point field calibration, RH or temperature (D) • Weatherproof housing for OSA and duct • 1% or 2% RH accuracy • Sintered filter OSA / Wall Housing (O) FM 9
APPROVED
SPECIFICATIONS Accuracy Wiring Terminations Nonpolar terminals, connect either 1% units ±1% from 10% to 80% RH way (22-14 AWG wire) 2% units ±2% from 0% to 90% RH Dimensions
Time Constant 60 sec in slow-moving air Room 4 5"H. x 2 .8"W x 1 .5"D HUMIDITY Supply Voltage 9 .4 VDC min to 35 VDC max (11 x 7 x 4 cm) Signal Output Two-wire, 4-20 mA over 0% to 100% Duct 4 6"L. x 2 .9"W x 2 3"D. RH and temperature (HT839) (22 x 7 3. x 5 .7 cm), 4 6". (11 .8 cm) Maximum Output probe length 0 .38" (0 .95 cm) Ø Impedance 730Ω @ 24 VDC (Power supply - 9 .4) OSA 10 .2"L x 2 .7"W x 2 .3"D / 0 02. A = Ω (26x 7 x 5 .7 cm), 8" (20 cm) probe Sensing Technology Capacitive monolithic IC (Humidity) length 1 .25" (3 .2 cm) Ø Sensor Protection Sintered filter (Humidity) Weight Calibration One-point adjustment Room 0 3. lb (0 .13 kg) Adjustments Zero, noninteracting Duct 1 1. lb (0 .5 kg) Operating Temperature OSA 1 16. lb (0 .53 kg) Room -10° to 150°F (-23° to 66°C) Warranty 3 years Duct/OSA -10° to 185°F (-23° to 85°C),
WIRING — HT829, RH ONLY WIRING — HT839, RH AND TEMPERATURE
24VDC 24VDC + - + -
Z S H T Z S Z S Hum* * Non-polar connections RH + Hum RH Signal – Hum* 4-20mA + Hum ** Need humidity connection 4-20mA to output temperature **Temp Signal – Temp* Signal – + Temp signal properly 4-20mA *Non-polar connections
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 507 HUMIDITY 1% AND 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS HT829, HT839
ORDERING INFORMATION
MODEL DESCRIPTION HT829 Relative humidity transmitter only HT839 Relative humidity transmitter and temperature transmitter D Duct mount, weather resistant box, 8" probe O Outside air mounting, weather resistant box with weather shield S Space room/office mounting 1 4-20 mA DC output N1 1% RH from 10/80% @ 25°C, temperature matched at 0°C with NIST certificate N2 2% accuracy from 0/90% @ 25°C, temperature matched at 0°C with NIST certificate S2 2% accuracy from 0/90% @ 25°C, no calibration data EN Range codes per Minco letter ranges (-20°/140°F) or (-29°/60°C) (HT839 only) S Range codes per Minco letter ranges (0°/100°F) or (-18°/38°C) (HT839 only) A Range codes per Minco letter ranges (20°/120°F) or (-7°/49°C) (HT839 only) BI Range codes per Minco letter ranges (30°/130°F) or (-1°/54°C) (HT839 only) N Range codes per Minco letter ranges (32°/122°F) or (0°/50°C) (HT839 only) H Range codes per Minco letter ranges (40°/90°F) or (4°/32°C) (HT839 only) 9 -- Range codes per Minco letter ranges in the catalog (HT839 only) SX Special range on next item line, -xxx/-yyyE, i.e., -20°/120°F (HT839 only) Example: HT839D1S2A HT839 D 1 S2 A 2% RH and temperature duct transmitter with 8" probe, temperature ranged for 20°/120°F
RELATED PRODUCTS PAGE DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995 HUMIDITY
508 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS KH2 SERIES
DESCRIPTION The Kele KHR, KHD, and KHO Series Humidity Transmitters are specifically designed for use in HVAC/BAS applications . These instruments measure relative humidity from 0% to 100% . The standard two-wire, 4-20 mA output provides low-cost humidity monitoring for building control . The RH transmitters are available with thermistor or RTD temperature sensors . They come in room (KHR), KHR duct (KHD), and OSA (KHO) mounting styles .
OPERATION The transmitter converts the relative humidity into a 4-20 mA signal with the latest microprocessor capacitive design . Multipoint factoryautomated calibration improves accuracy and repeatability . The optional temperature sensors, thermistor or RTD, offer direct connections to most automation systems . FEATURES • Calibration-free interchangeable sensors KHD • Twelve-point computerized calibration • ±2% accuracy (5% to 95% RH) • Replaceable sensor probe (no re-calibration) • No need to remove box to replace sensor probe • Attractive room enclosure design KHO • Two-wire, 4-20 mA output, 0% to 100% RH 9
SPECIFICATIONS Accuracy 2% RH @ 73°F (23°C) from 5% to KHD Metal handy box 90%; (0-5% & 90%-100%) add 3% KHO NEMA 3R plastic box Drift <±0 .5% per year Probe Thermal Effect 0 .05% / °F Duct Probe: 1/2" aluminum tube with Supply Voltage 9 .5-28 VDC expanded Teflon® filter
Signal Output 4-20 mA two-wire, loop-powered OSA Probe: 1/2" aluminum tube with 40 HUMIDITY Maximum Output micron stainless steel sintered filter Impedance 725Ω @ 24 VDC Wiring Terminations Screw terminals (Supply voltage - 9 .5 VDC) / 0 .02 Weight (Without Options) Sensing Technology Precon HS-2000 capacitive KHR 0 21. lb (0 .09 kg) Operating Humidity 0-100% Non-condensing KHD 1 2. lb (0 .59 kg) Operating Temperature -20° to 158°F (-29° to 70°C) KHO 0 52. lb (0 .24 kg) Enclosure Approvals RoHS KHR White plastic, UL94HB Warranty 18 months
WIRING
24 VDC Power Supply
J5 12-28 +V 4-20mA VDC RH Temperature RH Signal SENSOR LOOP sensor output to BAS Controller
J4
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 509 HUMIDITY 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS KH2 SERIES
DIMENSIONS Plug-in Replaceable Sensor
3.20 (8.12) Removeable Sensor Cover
2.50 1.30 (3.30) (6.35)
3.31 4.5 (8.40) (11.43) 1/2" Conduit Hole* (face down) Mounting Tabs (2) 4.10 (10.4) 2.50 (6.35)
Mounting Box
PC Board Clips 2.75 0.94 (6.98) (2.38) * Must face down 3.30 to maintain water- (8.38) Back Plate Front Side tight integrity 1/2" Conduit Hole* 9 (face down)
ORDERING INFORMATION
MODEL DESCRIPTION KHD2 Duct mounted 2% humidity transmitter KHO2 Outside air 2% humidity transmitter KHR2 Wall mounted room/space 2% humidity transmitter OPTIONAL TEMPERATURE RANGES T3 10,000Ω thermistor @ 77˚F (26˚C), Type III T21 2252Ω thermistor @ 77˚F (26˚C), Type II T22 3000Ω thermistor @ 77˚F (26˚C), Type II T24 10,000Ω thermistor @ 77˚F (26˚C), Type II T27 100,000Ω thermistor @ 77˚F (26˚C), Type II HUMIDITY T42 20,000Ω thermistor @ 77˚F (26˚C), Type IV T81 100Ω RTD @ 32˚F (0˚C), 385 platinum curve T85 1000Ω RTD @32˚F (0˚C), 385 platinum curve T91 1000Ω RTD @ 32˚F (0˚C), 375 platinum curve OPTIONS CL1 Custom one color logo, KHR2 only WP Weatherproof housing, KHD2 only XJ1 RJ11 externally-accessible communication jack (CCRJ11AD required), KHR2 only XJ2 Internal RJ11 communication jack, KHR2 only XLED LED indicator lamp 24V AC/DC green, KHR2 only XMB Momentary pushbutton switch, jumpered across sensor or pot (JP1), KHR2 only
KHD2 T3 WP Example: KHD2-T3-WP Duct mounted 2% humidity transmitter with 10,000Ω thermistor @ 77˚F (26˚C), Type III and weatherproof housing
ACCESSORIES HSR Replacement 2% humidity sensor for wall HSD Replacement 2% humidity sensor HSO Replacement 2% humidity sensor
RELATED PRODUCTS PAGE DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995
510 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS H_20K SERIES
DESCRIPTION The Kele Series H_20K Humidity Transmitters have been specifically designed for use in HVAC/BAS applications . These instruments measure relative humidity from 5% to 90% RH with 2% accuracy and produce a two wire 4-20 mA linear output . All are available with an optional passive RTD or thermistor . The duct and OSA versions may also be fitted with a 4-20mA temperature transmitter .
APPLICATION The temperature compensated circuitry converts the relative humidity into a 4-20 mA signal . The optional temperature FEATURES sensors, RTDs or thermistors, offer direct connection to most • 2% accuracy (5% to 90%) automation systems . On duct and OSA units, an optional 4-20 • Two-wire, 4-20 mA RH output mA temperature transmitter may also be employed and is • Optional temperature thermistor rangeable from -30° to 250°F (-34° to 121°C) . • Optional temperature RTD • Optional temperature 4-20mA (duct or OSA)
DIMENSIONS 9
in (cm) 2.13 2.875 (5.4) (7.3) 4.43 (11.3) 5.25 0.25 (13.3) 4.50 (0.64) (11.43) 4.625 2.88 (11.7) 1.25 (7.30) (3.18) 7.0
(17.8) 2.125 HUMIDITY (5.4) Foam gasket 3.23 (8.20) HW20K HD20K HO20K
SPECIFICATIONS Accuracy 2% RH @ 73°F (23°C) from 5% to Sensor Protection 90% RH; (0-5% & 90%-100%) (Duct and OSA) Sintered filter add 3% Operating Humidity 0-100% RH non-condensing Stability 0 .5% drift per year Operating Temperature -20° to 158°F (-29° to 70°C) Thermal Effect 0 .05% per °F Enclosure Supply Voltage 9 .5-28 VDC Room White plastic Signal Output 4-20 mA, thermistor, RTD Duct Weather resistant cast aluminum Maximum Output Wiring Terminations Terminal block (22 to 16 AWG) Impedance 725Ω @ 24VDC Weight (Supply voltage - 9 .5V) / 0 02. Room 0 3. lb (0 .09 kg) Measurement Range Duct 1 14. lb (0 .52 kg) RH 0-100% OSA 1 2. lb (0 .54 kg) Temperature -20° to 140°F (-29° to 60°C) Approvals RoHs (see ordering information) Warranty 1 5. year
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 511 HUMIDITY 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS H_20K SERIES
WIRING FOR RH ONLY AND "T" TEMPERATURE OPTION WIRING OR RH AND "TT" TEMPERATURE OPTION
Optional temperature sensor Power supply 24 VDC Temperature T 4-20 mA RH Humidity T signal V+ 4-20 mA RH Humidity signal V+ 4-20 mA Power Supply signal 24 VDC
Room, Duct, OSA (RH or RH-T) Duct and OSA with TT option only
MOUNTING ROOM AND DUCT SENSOR MOUNTING OSA SENSOR
DIAGRAM 1: The transmitter should be mounted so that the 9" (22.86 cm) probe is in the center of the The transmitter should be mounted duct. The transmitter should be duct mounted away from fans, corners, heating and cooling coils, and other preferably on the north side (Northern Hemisphere) of a building under the eave, equipment that will affect the measurement of relative humidity . not above windows or doors . The transmitter Optional Customer- Supplied Handy Box should be mounted vertically with the sensor Wire Access slots pointing down . Hole Plate 9 Mounting Screws
White Faceplate (standard) Cover Diagram 1 Mounting 1/16 Allen Screws Diagram 2 North Diagram 2: The sensor should be mounted approximately 5' (12.7 cm) above the floor, on an interior wall, away from any heating or cooling generating devices. Basic model comes with screw terminal block, two #6-32 screws for handybox mounting, and two #6 x 1" screws for direct wall mounting. Cover screws are #6-32 with a 1/16 allen key head. Precautions should be taken to prevent air infiltration from inside the wall. HUMIDITY
ORDERING INFORMATION
MODEL DESCRIPTION HW20K 2% beige room humidity transmitter, 4-20 mA output HW21K 2% white room humidity transmitter, 4-20 mA output HD20K 2% duct-mount humidity transmitter, 4-20 mA output HO20K 2% OSA-mount humidity transmitter, 4-20 mA output OPTIONS (Temperature Sensors or Transmitters) -- No temperature sensor T3 10,000Ω thermistor @ 77°F (25°C), Type III T21 2252Ω thermistor @ 77˚F (26˚C), Type II T22 3000Ω thermistor @ 77˚F (26˚C), Type II T24 10,000Ω thermistor @ 77°F (25°C), Type II T27 100,000Ω thermistor @ 77˚F (26˚C), Type II T42 20,000Ω thermistor @ 77˚F (26˚C), Type IV T63 1000Ω nickel SS flush mounted plate RTD @ 70˚F (26˚C), Type III (yellow leads) T71 100Ω SS flush mounted plate RTD @ 32˚F (0˚C), Type III (blue leads) T81 100Ω RTD @ 32˚F (0˚C), 385 platinum curve T85 1000Ω 385 platinum RTD T91 1000Ω 375 platinum RTD TT-2 -20° to 140°F (-29° to 60°C) transmitter, 4-20 mA (duct and OSA only) TT-3 0° to 100°F (-18° to 38°C) transmitter, 4-20 mA (duct and OSA only)
HD20K T3 Example: HD20K-T3 Duct-mount humidity sensor with 10 kΩ Type III temperature sensor
RELATED PRODUCTS PAGE DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995
512 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY 2% ROOM HUMIDITY TRANSMITTER HS20K SERIES
DESCRIPTION The Kele Model HS20K-C and HS20K-V Humidity Transmitters has been specifically designed for use with HVAC/BAS applications and, with its unique low- profile design, is perfect for museums, institutions or other architecturally challenging locations . The HS20K will monitor humidity from 5% to 95% with 2% accuracy with an 4-20 mA analog current output or a 0-5 VDC voltage output . The HS20K Series is available with optional passive temperature sensors . FEATURES • 2% accuracy • 4-20mA or 0-5 VDC analog outputs • Passive temperature sensors output optional • Stainless steel plate mounted HS20K
SPECIFICATIONS DIMENSIONS Accuracy 2% RH @ 73°F (23°C) from 5% to in 90%; (0-5% & 90-100%) add 3% 2.75 Thermal Effect 0 .05% per °F (cm) (6.99) 9 Supply Voltage HS20K-C 9 .5-28VDC HS20K-V 5 VDC Signal Output HS20K-C 4-20 mA, two wire loop powered, passive thermistor or RTD 4.50 3.25 HS20K-V 0 to 5 VDC, passive thermistor or (11.43) (8.25) RTD HUMIDITY Maximum Output Impedance 725Ω @ 24VDC (Supply voltage – 9 5V). / 0 .02 Sensing Technology Precon HS-2000 capacitive Operating Humidity 0-100% RH non-condensing Operating Temperature -20° to 158°F (-29° to 70°C) Enclosure Flush mounted stainless steel plate Wiring Terminations Terminal block (22 to 16 AWG) Weight 0 .34 lb (0 15. kg) Approvals RoHS Warranty 18 months WIRING
Power Supply 24 VDC
VOLTAGE WIRING + –
(DCP-524 power supply 4-20 mA recommended) Signal
Temperature (optional)
Pin 1 - not used Pin 2 - Power (5 VDC) Pin 3 - RH Out (5 VDC) HS20K-C 4-20mA Current Output 4 3 2 1 Pin 4 - Ground
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 513 HUMIDITY 2% ROOM HUMIDITY TRANSMITTER HS20K SERIES
ORDERING INFORMATION
MODEL DESCRIPTION HS20K-V Stainless steel wall plate humidity sensor with 0-5 VDC output HS20K-C Stainless steel wall plate humidity sensor with 4-20 mA output OPTIONS T3 10,000Ω thermistor @ 77˚F (26˚C), Type III (gray leads) T21 2252Ω thermistor @ 77˚F (26˚C), Type II (green leads) T22 3000Ω thermistor @ 77˚F (26˚C), Type II (blue leads) T24 10,000Ω thermistor @ 77˚F (26˚C), Type II (yellow leads) T27 100,000Ω thermistor @ 77˚F (26˚C), Type II (gray leads) T42 20,000Ω thermistor @ 77˚F (26˚C), Type IV(green leads) T63 1000Ω nickel RTD @ 70˚F (26˚C) (yellow leads) T71 100Ω RTD @ 32˚F (0˚C) (blue leads) T81 100Ω RTD @ 32˚F (0˚C), 385 curve (yellow leads) T85 1000Ω RTD @32˚F (0˚C), 385 curve (blue leads) T91 1000Ω RTD @ 32˚F (0˚C), 375 curve (green leads)
HS20K-V T3 Example: HS20K-V-T3 2% SS wall plate humidity transmitter with 9 0-5 VDC output with Type III 10,000Ω thermistor
RELATED PRODUCTS PAGE DCP-1.5-W-C Power supply, 24 VAC In to special DC output (Specify output voltage when ordering, 1.5-24 VDC) 995 DCP-524 Power supply, 24 VAC IN to 24 VDC and 5 VDC OUT 997 DCPA-1.2-C Power supply, 120 VAC In to 24 VAC/ Special DC output (Specify output voltage when ordering, 1.3-27 VDC) 994 HUMIDITY
514 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS GEH2 SERIES
DESCRIPTION The Amphenol Advanced Sensors Model GEH2 Series 2% Accuracy Humidity Transmitters are designed specifically for commercial building automation systems (BAS) . The room, duct and OSA transmitters use replaceable sensor tips and switch selectable transmission including 4-20mA, 0-5V or 0-10VDC . The GEH also has an optional temperature transmitter output with selectable outputs(RH&T must be the same type) . All duct and OSA enclosures are rated for IP42 or NEMA 3R applications .
Room FEATURES OSA Duct • ±2% accuracy • Temperature compensated APPLICATIONS • Field-selectable 4-20 mA, 0-10V, or 0-5V outputs • Hospitals/pharmaceuticals • Replaceable sensor • HVAC building controls • Swimming pools • Optional temperature transmitter • Clean rooms • Museums / archives • Animal rooms 9
SPECIFICATIONS WIRING Accuracy 2% (10% to 90%) Supply Voltage 18-30 VDC, 100mA VOLTAGE MODE CURRENT MODE Signal Output 4-20 mA/0-5V/0-10V selectable; 0-100% RH VI VI VI VI HUMIDITY Maximum Output SW1 SW3 SW1 SW3 Impedance 700Ω maximum @ 24 VDC Switch Positions for Voltage Mode Switch Positions for Current Mode Minimum Output Switch Selectable 0-5 V or 0-10 V Output Impedance 10 kΩ minimum 10V 24 VDC I1RH/P+ Sensing Technology Capacitive and replaceable V-TMP + Temp – Input 4-20 mA/RH I2RH/P– Operating Humidity 0% to 99%, non-condensing GND
2 – RH 4-20 mA/Temp I2-TMP Operating Temperature -40° to 140°F (-40° to 60°C) V-RH + Input SW TH Not Enclosure Rating I2RH/P– – used 24 VDC TH Room ABS plastic, UL94V Room Installed 5V I1RH/P+ + IP20, NEMA 1 J7 J8 Duct/OSA IP42, NEMA 3R Stainless steel RH and Temperature - Voltage RH and Temperature - Current Loop with removable tip, PTFE Teflon® shield, Wiring Terminations 16 to 22 AWG terminals VI Weight SW3
Room 0 .34 lb (0 .15 Kg) VI Duct 0 .96 lb (0 .44 Kg) SW1 3K OSA 1 .22 lb (0 .55 Kg) JPR1 Current Warranty 2 years 10K 10V Voltage 2 SW
J7 J8 5V
Connector and Switch Locations
Only one terminal block provided; move for either voltage or current.
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 515 HUMIDITY 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS GEH2 SERIES
DIMENSIONS
2.75 in (7.0) (cm) 2.75 8.80 (22.37) 1/2'' (7.0) 3.80 Cover Base (1.27) (9.63) 4.70 knockout (11.92) (each side)
4.70 4.70 Wiring 4.70 (11.92) (11.92) Access (11.92) 0.5 (1.27)
1.28 6.38 (3.24) (16.2)
Outside Air Cover (all mounts) Space (Wall) Mount Mount Duct Mount 2.37 (6.03)
9 ORDERING INFORMATION
MODEL DESCRIPTION GEH2 RH transmitter 2% accuracy RH MOUNTING ENCLOSURE S Decorative room mounting enclosure D Duct mounting with ABS plastic IP42 enclosure O OSA mounting with ABS plastic IP42 enclosure and weather shield SN Decorative room mounting enclosure with NIST certificate DN Duct mounting with ABS plastic IP42 enclosure with NIST certificate ON OSA mounting with ABS plastic IP42 enclosure and weather shield with NIST certificate HUMIDITY TEMPERATURE OPTION TT0 Transmitter, 40° to 90°F (4.4° to 32.2°C) (S, D, SN, and DN only) TT2 Transmitter, -20° to 140°F (-29° to 60°C) (D, O, DN, and ON only) TT3 Transmitter, 0° to 100°F (-18° to 38°C) (All enclosure mounts)
Example: GEH2-SN 2% room RH transmitter with NIST certificate GEH2-D 2% duct RH transmitter
RELATED PRODUCTS PAGE GEH2-RH Replaceable 25% humidity sensor for room, duct, and OSA GEH2-RHTT Replaceable 2% humidity and temperature sensor for room, duct and OSA transmitters DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995
516 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY 2% DUCT AND OSA HUMIDITY TRANSMITTERS HMD60, HMD70, AND HMK41K
DESCRIPTION Vaisala’s Models HMD60 and HMD70 Duct Mount Relative Humidity Transmitters have been specifically designed for use in HVAC/BAS and pharmaceutical applications . These instruments measure relative humidity from 0% to 100% . They are easily installed and meet the European CE standards .
Five-minute field calibration is possible using theModel HMK41K Humidity Calibrator . When accuracy adjustment or sensor replacement is necessary, the transmitter can be HMD 60 or calibrated in seconds with a single potentiometer without HMD 70 disturbing operation . This saves hours of maintenance time and assures high accuracy .
FEATURES • Comes with NIST certificate • Full 0% to 100% RH measurement • State-of-the-art replaceable sensor technology 9
SPECIFICATIONS HMD60, HMD70 Enclosure Rating Cast aluminum NEMA 4 (IP55), Accuracy ABS plastic Humidity ±2% RH (0% to 90% RH) @68°F Wiring Terminations Screw terminals (20-16 AWG) (20°C) Approvals CE Temperature ±0 .2°C Weight HUMIDITY Supply Voltage Duct 1 68. lb (0 .76 kg) 60 Series 10 to 35 VDC Warranty 1 year 70 Series 10 to 35 VDC, 9 to 24 VAC @ 0 .3 VA (signal dependant) HM41K Maximum Output Sensor Capacitive and replaceable Impedance 500Ω @ 24 VDC Operation Handheld, onsite calibrator Minimum Output Reference Probe Impedance 3000Ω min Accuracy ±1% RH (0% to 90% RH) Measurement Range ±2% RH (90% to 100% RH) Humidity Measuring range 0% to 100% RH, Duct Mount 0% to 100% -40° to 140°F (-22° to 78°C) Temperature Operating temperature -40° to 140°F (-40° to 60°C) Duct Mount -4° to 176°F (-20° to 80°C) Storage temperature -4° to 140°F (-20° to 60°C) Sensing Technology Capacative and replaceable, Vaisala Temperature coefficient HUMICAP® 180 +0 .04% RH/°C typical Operating Temperature Agency approvals CE, NIST certificate Electronics 23° to 131°F (-5° to 55°C) Weight 2 1. lb (0 .95 kg) Sensor Head (Duct) -4° to 176°F (-20° to 80°C), Warranty 1 year
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 517 HUMIDITY 2% DUCT AND OSA HUMIDITY TRANSMITTERS HMD60, HMD70, AND HMK41K
DIMENSIONS
Outside Wall 3.94 (10.01) Northern Exposure in 3.23 (8.20) (Northern Hemisphere) (cm) End View into Sensor 3.23 3.94 (8.20) (10.01) Mounting Bracket 2.50 (6.35) 4.50 (11.43)
0.47 1.75 (1.19) 3.50 (8.89) (4.45) Sun/Rain Shield
2.44 (6.20) 9.85 (25.01) Side View 10.0 (25.40) HMD 60/70 Duct RH WMK-20 Outside Air Bracket
WIRING
T RH Test RH 9 gain RH gain RH offset 1 2 3 4 5 offset 1 2 3 4 5
T T T T gain offset gain offset HMD 60U or HMD 60Y HMD 70U or HMD 70Y Us RH T GND +RH-RH +T -T Output Selections Y Option Power out out Y Option 4-20 mA 0-1V T Supply Voltage Temperature Signal RH Power Temperature Signal 0-5V T Supply RH 4-20 mA Voltage RH Signal T RH Signal Duct Current Output 0-10V RH Duct Voltage Output
ORDERING INFORMATION HUMIDITY
MODEL DESCRIPTION HMD60U Duct RH transmitter, 4-20 mA output HMD60Y Duct RH and temperature transmitter, 4-20 mA output HMD70U Duct RH transmitter 0-1V, 0-5V, 0-10V output HMD70Y Duct RH and temperature transmitter, 0-1V, 0-5V, 0-10V output HMW60U Wall mount, RH transmitter, 4-20 mA output HMW60Y Wall mount, humidity with 4-20 mA output , temperature with 4-20 mA output HMW70U Wall mount, RH transmitter, 0-1 VDC, 0-5 VDC, 0-10 VDC outputs HMW70Y Wall mount, humidity, and temperature, 0-1 VDC, 0-5 VDC, 0-10 VDC outputs
RELATED PRODUCTS PAGE HMK41K 2% handheld calibrator with calibration cable HUMICAP180 Replacement humidity sensor (replaces 0062HM) WMK-20 OSA/Wall-mount bracket DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995
518 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS A/RH2 SERIES
DESCRIPTION The ACI A/RH2 Series Relative Humidity Transmitters utilize a capacitive sensing element to deliver a proportional 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC output . It is available for room, duct, outside, and stainless steel wall plate applications . The A/RH2 Series has on board DIP switches which allow the user to select the desired output signal and can be powered by AC or DC power sources . A/RH2-O Each A/RH2 Series humidity transmitter is calibrated using a NIST Traceable Temperature/Humidity Chamber . Three and five A/RH2-R point NIST calibration certificates are available and optional .
FEATURES A/RH2-SP • Popular room housing • Accuracies of 2%, 3% or 5% • Three-year warranty • Duct and OSA twist-off NEMA 4 housing • 24 VDC or 24 VAC power (field-selectable) A/RH2-D • 4-20 mA, 0-10V, or 0-5V signal (field-selectable) • Field calibratable • Digital display option • Optional temperature sensor 9 SPECIFICATIONS Accuracy ±2% @ 77°F (25°C) from 10% to 95% Dimensions Thermal Effect <0 .005% per °F (<0 .01 per °C) Room 3 .8"H x 2 .8"W x 0 .9"D Supply Voltage 12-40 VDC or 24 VAC, selectable (9 .8 x 7 x 2 .3 cm) Signal Output 4-20 mA, 0-5 VDC, 0-10 VDC (field Duct 3 .6" (9 cm) Ø head with 8 15"L. selectable) (20 cm) probe 0 .75" (1 .9 cm) Ø Measurement Range 0% to 100% OSA 3 .6" (9 cm) Ø head with 3 0"L. (7 .6 cm)
Sensing Technology Capacitive probe 1 .4" (3 6. cm) Ø HUMIDITY Operating Temperature Weight Room 32° to 122°F (0° to 50°C) Room 0 .22 lb (0 .1 kg) Duct/OSA -40° to 140°F (-40° to 60°C) Duct 1 .21 lb (0 .54 kg) Enclosure OSA 0 .6 lb (0 .27 kg) Room Plastic Delta-style SP 0 .2 lb (0 .09 kg) Duct/OSA Plastic weatherproof Approvals CE, RoHS Warranty 5 years
WIRING
2 Wire Current Output Signal
Output Selection Switches (SW 1) DC Supply Voltage 4-20 mA Output 4-20 mA Output ON ON 4-20mA VIN COM VOUT 3 Wire Current Output Signal OFF Supply Ground / Signal Common 0-10 VDC Output AC or DC Supply Voltage 4-20 mA Output ON ON
4-20mA VIN COM VOUT OFF Voltage Output Signal 0-5 VDC Output 0-10 or 0-5 VDC Output Signal ON Supply Ground / Signal Common ON AC or DC Supply Voltage OFF 4-20mA VIN COM VOUT
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 519 HUMIDITY 2% WALL, DUCT AND OSA HUMIDITY TRANSMITTERS A/RH2 SERIES
DIMENSIONS
4.68 (11.9) 3.84 4.24 (10.8) 0.75 2.25 3.60 (9.1) 3.95 (10.0) (1.9) in (5.7) 0.89 (9.8) (cm) (2.3) 2.69 0.79 (6.8) (2.0) 2.25 0.86 (5.7) (2.2) 1.00 (2.5) 6.10 (4) PG11/0.5" (1.27) NPT Knockouts 3.84 4.51 (15.5) (9.8) (11.5) 3.00 (7.6)
0.60 PG11 Watertight Fitting (1.5) 1.40 (3.6) (Cable Dia. 0.12 to 0.28"/ 2.75 0.92 0.3 to 0.7 cm) (7.0) (2.3)
Room Outside
0.65 (1.7) 0.75 (1.9) 80 Micron Sintered 2.75 (7.0) Stainless Steel Filter 1.40 Plastic (3.6) Washer 80 Micron 1.07 Stainless 0.75 9 (2.7) Steel (1.9) Sintered FIlter 4.5 (1.4) 1.00 0.58 (2.5) 7.15 (1.5) (18.2) 2.70 0.18 (6.9) (0.5) O.D. Ref 0.46 (1.2) Plastic Cover for Stainless Steel Filter to 2.25 Stainless Protect Sensor during (5.7) Plate Wash Down
0.75 (1.9) Duct Stainless Plate HUMIDITY ORDERING INFORMATION
MODEL DESCRIPTION A/RH2 2% accuracy humidity transmitter AN Type III 10,000Ω thermistor CP Type II 10,000Ω thermistor 20K 20,000Ω thermistor 100 100Ω 385 PT RTD 1K 1,000Ω 385 PT RTD R Room D Duct O Outside air SP Stainless steel plate passive sensors only A/RH2 --100 R Example: A/RH2-100-R A 2% accuracy room humidity transmitter with 100Ω RTD
RELATED PRODUCTS PAGE DCP-1.5-W Power supply, 24 VAC IN to 24 VDC OUT 995 DCPA-1.2 Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 691-K0A Control transformer, 120:24 VAC, 40 VA, Class 2 979
520 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 HUMIDITY ROOM, DUCT, AND OSA 2% HUMIDITY TRANSMITTERS HT2D, HT2O, HT2S
DESCRIPTION The Minco Model HT relative humidity transmitters are full-range, high-accuracy building automation transmitters . Model HT covers 0% to 100% RH over a wide temperature . The standard two-wire, 4-20 mA output provides low cost space, duct, and outdoor monitoring for building control .
OPERATION HT2D The transmitter converts the relative humidity into a 4-20 mA signal . The HT transmitters have a microprocessor that performs the temperature compensation calculations from an onboard RTD . The microprocessor maintains both high accuracy and low cost with a wide humidity and operational temperature span .
An added optional temperature output is available in the same enclosure . It comes with a 4-20 mA signal and a large selection of temperature ranges . HT2S HT2O The housings for the duct- and OSA-mount configurations are 9 suitable for outdoor use . The aluminum cast box is gasketed to maintain a rain-tight environment for the transmitter . FM C US APPROVED FEATURES • 100% replacement for discontinued Hycal transmitters • Advanced wall-mount design
• Weather-resistant housing for duct and OSA use HUMIDITY • Dual output option (humidity and temperature)
SPECIFICATIONS Accuracy Sensing Technology Humidity ±2% (5 to 90% RH) Humidity Capacitive monolithic IC Temperature ±0 .5°F (0 .27°C) Temperature Platinum 1000Ω RTD 385 curve Supply Voltage 9 .4-35 VDC (24V nominal) Operating Temperature Signal Output 4-20 mA Room -10° to 150°F (-23° to 65°C) Maximum Output Duct/OSA -10° to 185°F (-23° to 85°C) Impedance (Power supply – 9 4V). / 0 .02 = load, Wiring Terminations Nonpolar terminals i .e ., (24V – 9 .4V) / 0 02. = 730Ω (22-14 AWG wire) Measurement Range Weight Humidity 0 to 100% RH Room 0 3. lb (0 .13 kg) Temperature Duct 1 1. lb (0 .50 kg) “EN” Range -20° to 140°F (-29° to 60°C) OSA 1 16. lb (0 .53 kg) “S” Range -0° to 100°F (-18° to 38°C) Warranty 3 years “H” Range 40° to 90°F (4° to 32°C)
March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 521 HUMIDITY ROOM, DUCT, AND OSA 2% HUMIDITY TRANSMITTERS HT2D, HT2O, HT2S
DIMENSIONS
2.75 (6.99)
2.75 (6.98) 4.63 4.0 (11.75) (10.16) 4.5 (11.43) 2.25 Housing Bottom View (5.72) 2.88 1.25 (7.30) 4.50 (3.18) (11.43) 0.38 (0.953)
1.58 (4.01) 2.0 Foam Gasket (5.08) 8.0 (20.32) Housing Top View HT2S HT2O HT2D
WIRING 9 24 VDC Power Supply
Hum* Hum
Temp* Temp * Non-polar connection 4-20 mA 4-20 mA ** Needs humidity connection Humidity Optional HT2S to output temperature Signal Temperature signal properly Signal** HUMIDITY ORDERING INFORMATION