Flow Control - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Contents Flow Control Valves CV SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

NEEDLE VALVES Check Valves J02A2 ...... C08-2 ...... Needle , Cartridge Type ...... 45/12 ...... 420/6000 ...... FC5-FC6 SH ✰ NVH081 ...... C08-2 ...... , Cartridge Type ...... 38/10 ...... 380/5500 ...... FC7-FC8 ✰ NVH101 ...... C10-2 ...... Needle Valve, Cartridge Type ...... 60/16 ...... 380/5500 ...... FC9-FC10 J06A2 ...... C16-2 ...... Needle Valve, Cartridge Type ...... 225/60 ...... 420/6000 ...... FC11-FC12 Shuttle Valves

J02B2 ...... C08-2 ...... Needle Valve with Reverse Check, LM ...... 2 to 1 Free Flow ...... 30/8 ...... 420/6000 ...... FC13-FC14

FV101 ...... C10-2 ...... Needle Valve with Reverse Check, Load/Motor Controls ...... 1 to 2 Free Flow ...... 45/12 ...... 210/3000 ...... FC15-FC16 FC FV102 ...... C10-2 ...... Needle Valve with Reverse Check, ...... 1 to 2 Free Flow ...... 23/6 ...... 210/3000 ...... FC15-FC16 Flow Controls PRESSURE COMPENSATED FLOW CONTROLS PC J02E2 ...... C08-2 ...... Restrictive Flow Control, Adjustable ...... 20/5.3 ...... 420/6000 ...... FC17-FC18 FR101 ...... C10-2 ...... Restrictive Flow Control, Tuneable ...... 26/7 ...... 245/3500 ...... FC19-FC20 J04E2 ...... C10-2 ...... Restrictive Flow Control, Adjustable ...... 40/10 ...... 420/6000 ...... FC21-FC22 Pressure Controls J04C2 ...... C10-2 ...... Restrictive Flow Control, Adjustable ...... 40/10 ...... 420/6000 ...... FC23-FC24 LE

FA101 ...... C10-2 ...... Restrictive Flow Control, ...... Reverse Check, Adjustable ...... 21/5.5 ...... 210/3000 ...... FC25-FC26

FC101 ...... C10-2 ...... Restrictive Flow Control, Logic Elements ...... Reverse Check, Tuneable...... 56/15 ...... 210/3000 ...... FC27-FC28 DC

PRESSURE COMPENSATED PRIORITY FLOW CONTROLS Directional Controls J02D3 ...... C08-3 ...... Priority Type, with Bypass ...... 15/4 ...... 420/6000 ...... FC29-FC30 MV FP101 ...... C10-3 ...... Priority Type, with Bypass ...... 56/15 ...... 245/3500 ...... FC31-FC32 J04D3 ...... C10-3 ...... Priority Type, with Bypass ...... 45/12 ...... 420/6000 ...... FC33-FC34 J1A125 ...... 3A ...... Priority Type, with Bypass ...... 90/24 ...... 350/5000 ...... FC35-FC36 Manual Valves SV PRESSURE COMPENSATORS FCR101...... C10-3 ...... Restrictive Type, Press. Compensators ...... 38/10 ...... 245/3500 ...... FC37

FCR161...... C16-3 ...... Restrictive Type, Press. Compensators ...... 150/40 ...... 245/3500 ...... FC38

Valves Solenoid PV Note: Also see R04C3 on page DC1.

PRIORITY PRESSURE COMPENSATORS FCP101 ...... C10-4 ...... Priority Type, with Bypass ...... 56/15 ...... 245/3500 ...... FC39 Proportional Valves FCPH121 ...... C12-4 ...... Priority Type, with Bypass ...... 95/25 ...... 380/5500 ...... FC41-FC42 CE Coils & Electronics FLOW DIVIDERS/COMBINERS BC FDC101...... C10-4 ...... Flow Divider/Combiner ...... 45/12 ...... 245/3500 ...... FC43-FC44 L04A3 ...... C10-4 ...... Flow Divider/Combiner ...... 60/16 ...... 420/6000 ...... FC45-FC46

L06A3 ...... C16-4 ...... Flow Divider/Combiner ...... 180/47 ...... 420/6000 ...... FC47-FC48 Cavities L1A300 ...... 91-1 ...... Flow Divider/Combiner ...... 320/85 ...... 350/5000 ...... FC49-FC50 & Bodies TD

✰Denotes New Winner’s Circle Product Line. Technical Data

Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Technical Tips Flow Control Valves CV INTRODUCTION Valves Check This technical tips section is designed to help familiarize you with the Parker line of Flow Control Valves. In this section we present common options available as well as a brief synopsis of the operation and applications of the various product offered in this section. The intent of this section is to help you in selecting the best products for SH

your application.

Shuttle Valves

COMMON OPTIONS LM Load/Motor As you will see, Parker offers a variety of Flow Control products. As such, some of the options mentioned below Controls may not be available on all valve models. Consult the model coding and dimensions of each valve for specifics. Here are some of the common options available.

FC

Controls Adjustment Types: Parker offers four primary types Tamper Resistant - The tamper Flow of adjustments for most of the flow control products. resistant option is a screw adjustable Samples of these types are shown below. Please note valve with a steel cap installed to con- PC all options may not be available for all valves. Consult ceal the adjustment. The cap is designed Pressure Controls the individual catalog pages for more details. so the internal edges clamp into the groove of the valve adapter. Once the cap is installed, it cannot be removed LE Screw Adjustment - Valve can be without damaging the cap and the valve.

Elements adjusted with an allen wrench. Lock When a valve is ordered with the tamper resistant

Logic nut included to maintain desired option, it will be preset at the factory, and the cap will setting after adjustment. This is the be included in a separate plastic bag to allow for fine most common adjustment option tuning at the customer site. Parker offers tamper re- DC

Directional available on most Parker products. sistant cap conversion kits for most flow control valves.

Controls For kit numbers consult the individual valve pages.

Knob Adjustment - An aluminum Seals: The Winner’s Circle products feature a MV knob is added to the standard screw standard 4301 Polyurethane “D”-Ring. The “D”-Ring adjustment. A lock knob is provided eliminates the need for backup rings.The majority of Manual Valves to help maintain the desired setting the products are available in Nitrile or Fluorocarbon after adjustment. Parker offers knob Seals. You should match the seal compatibility to the conversion kits for most flow control temperature and fluid being used in your application. SV valves. For kit numbers consult the Solenoid

Valves individual valve pages. Fine Meter Options: Fine meter needles are offered on some needle valve series. When this option is specified, the standard needle is replaced by a slotted PV Fixed Style - In most cases, the needle. The slotted needle restricts substantially more Proportional Fixed Style product is a screw flow giving you finer control in the small flow ranges. Valves adjustable product with a steel collet Obviously, the maximum flow capacity of the needle threaded over the adjustment. valve is decreased with the fine meter option. These valves are preset at the CE Coarse Needle Electronics factory. Should the valve need to

Coils & adjusted, the star washer and aluminum plate can be removed from the top of the assembly exposing the BC adjustment. Bodies & Cavities Fine Needle

TD Technical Data

FC1 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Technical Tips Flow Control Valves CV PRODUCT TYPES / APPLICATIONS

Needle Valve Check Valves Needle valves provide uncompensated SH adjustable flow control of a desired function. They are ideal for applications where general control of hydraulic flow

(1) Shuttle Valves is needed, like in a bleed off circuit. LM When used with a compensator spool, a pressure compensated system can be obtained. (2)

OPERATION - The valve acts as a fixed orifice in a hydraulic circuit. The effective size of the Load/Motor Controls orifice increases as the tapered needle is opened. Shutoff is provided when fully closed. While FC a needle valve will meter flow regardless of the flow path, flow from port 2 to 1 is preferred. When you flow in the reverse direction (1 to 2), pressure forces work on the nose of the needle

in an effort to drive it off of its seat. As such, all leakage conditions found in the catalog are Flow Controls based on flow from side to nose (port 2 to port 1). In addition, the adjustment will be harder to PC turn due to the added force.

Needle with a Reverse Check Pressure Controls Needle valves with reverse check LE functions are sometimes also referred to as flow control valves. As the name implies, these valves provide uncom-

(1) Logic Elements pensated adjustable speed control in one DC direction and allow free flow in the opposite direction. When used with a compensator spool, a pressure (2) compensated system can be obtained. Directional Controls OPERATION - With flow entering the side of the cartridge (port 2), the needle acts as a fixed MV orifice. The effective size of this orifice is increased as the needle is opened controlling the output flow to port 1. With flow entering the nose (port 1), the check ball inside the needle is

unseated allowing free flow to port 2. Manual Valves SV P.C. Flow Regulator

Pressure compensated flow regulators Valves maintain a regulated flow regardless of Inlet Solenoid (1) changes in load or inlet pressure. They PV are commonly used to accurately control an actuator function. They can be used in Reg. (2)

meter-in or meter-out applications. Proportional Valves CE OPERATION - The valve consists of a control orifice within a normally open, spring biased compensator spool. Flow through the control orifice produces a pressure drop across the compensator spool. When inlet flow exceeds the flow setting of the valve, the force produced by the pressure differential across the spool exceeds the spring force and shifts the Coils & Electronics compensator spool to throttle or restrict flow; thus maintaining consistent flow through the BC

valve. In the reverse direction, flow is metered, but not pressure compensated.

Cavities Bodies & Bodies TD Technical Data

FC2 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Technical Tips Flow Control Valves CV P.C. Flow Control Valves Check Pressure compensated flow controls are pressure compensated regulators with a reverse flow . They (1)

SH provide constant regulated flow in the Shuttle Valves one direction regardless of changes in (2) load pressure. Flow in the reverse direction is non-regulated, free flow. They can be used in meter-in or meter-out applications.

LM Load/Motor

Controls Adjustable Flow Controls Most adjustable pressure compen- sated flow controls have a limited adjustment range. You will see in our FC (1) catalog that we use the term “tuneable” Controls for the FR101 and FC101 valves. Flow This means they are only adjustable within a pre-set range. (2) The FA101, J02E2, J04E2 and J04C2 are fully adjustable. PC Keep this adjustment capability in mind when you select a flow control. Pressure Controls OPERATION - When flow enters the nose (port 1) of the cartridge, it passes through a control orifice. This control orifice creates a pressure differential across the regulating spool. As the inlet flow increases, the pressure differ- LE ential across the regulating spool increases, allowing the regulating spool to overcome its spring force and begin

Elements to shift. As it shifts, it throttles to maintain a constant flow. When used in conjunction with a fixed displacement

Logic pump, a relief valve between pump and valve is needed. Full flow is allowed in the reverse direction (port 2 to 1).

DC Priority Style P.C. Flow Regulator Directional

Controls Priority style pressure compensator regulators maintain constant priority flow to one leg of the circuit regardless of (1) changes in load or inlet pressure. Once MV this priority flow requirement is satisfied, (2) (3) Manual Valves the excess flow is diverted and can be used in another leg of the circuit. These valves are usually used in meter-in applications.

SV OPERATION - The valve consists of a control orifice within a spring biased compensator spool. The priority port

Solenoid is normally open while the bypass port is normally closed. As flow enters the inlet of the cartridge and passes Valves through the control orifice, a pressure differential is created across the compensator spool. When the inlet flow exceeds the setting of the valve, the force produced by this pressure differential exceeds the spring force and PV shifts the compensator spool; opening up the bypass port, and bypassing the excess flow. If load pressure at the Proportional bypass port is greater than the load pressure at the priority port, the compensator spool will further shift restricting

Valves the priority flow to that of the valve setting. Caution: If the priority line is blocked so that no flow can pass through the control orifice, the compensator spool will shift, blocking the bypass port and allowing inlet pressure to go to full system relief pressure. These valves do not provide a pressure relieving function, so it is common to place an CE

Electronics external relief valve downstream of port 3 to prevent a no flow condition. Coils &

BC Bodies & Cavities

TD Technical Data

FC3 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Technical Tips Flow Control Valves CV Compensator Valves Restrictive Type Compensator valves are used to provide pressure compensated (1) control across an external fixed Check Valves or adjustable orifice. Parker offers SH (2) (3) both the restrictive type of compensator and a priority style. Shuttle Valves OPERATION - Restrictive Type: Priority Type LM Inlet flow (upstream of the orifice) is split with one portion going to the (1) compensator port inlet (port 1), Load/Motor Controls the other portion passes through the (2) (3) (4) FC orifice to the supply port (port 3). As pressure drop across the orifice reaches the selected compensator pressure drop, the higher pressure (pre-orifice) at port 1 starts to shift the compensator spool into throttling position. The valve works to maintain a constant pressure drop across the orifice. Flow Controls Priority Type: Flow through the external orifice into the supply port (port 4) produces a pressure drop across the PC compensator spool. When the inlet pressure exceeds the initial setting of the valve, the force produced by the pres- sure differential across the spool exceeds the spring force and shifts the compensator spool to throttle or restrict

the flow, thus maintaining constant flow through the priority port (port 3). The excess flow is bypassed to port 2. Pressure Controls Regulated port flow must be maintained for bypass flow to continue. LE

Flow Divider / Combiner Divider Outlets Combiner Inlets Flow divider / combiner valves are used Logic Elements to proportion the flow from a single source DC into two actuators. In the reverse mode, the valve takes the flow from the two Divider Inlet

sources and combines it into one flow. Directional Controls Combiner Outlet When attempting to synchronize two cylinders (1) (2) (3) MV with a flow/divider combiner valve, please consider that the flow accuracy is +10%. A crossover relief can be used to help re-synchronize the cylinders by bottoming them out after several cycles.

OPERATION - When flow enters the divider inlet port, it will pass through orifices in each of the interconnected Manual Valves spools. The flow passing through the orifices creates a pressure drop which pulls the two spools away from each SV other. The flow then passes to the two divider outlet ports. The division of flow (i.e. 50-50, 60-40, 66-33, etc.) is

determined by the orifice sizes in the two spools.When flow is being combined, it enters the valve through two Valves combiner inlets. The pressure drop across the orifices pulls the two spools together. The combined flow then Solenoid passes through the combiner outlet. PV Proportional Valves CE Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC4 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series J02A2 CV General Description Valves Check Cartridge Style Needle Valve. For additional information see Technical Tips on pages FC1-FC4.

SH Shuttle Valves Features • Shuts off to a very low leakage level LM High flow capacity from a small cavity Load/Motor • Controls • Good adjustment sensitivity - ideal for fine control • Good contamination tolerant • Adjustable and tamperproof versions available FC • All external parts zinc plated (2) Controls

Flow (1) (2)

(1) PC Pressure Controls

LE

Elements Specifications Performance Curves (Through cartridge only)

Logic Low Pressure Drop vs. Flow 1 to 2 & 2 to 1 Rated Flow 45 LPM (12 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) 290 20 DC Maximum Inlet 420 Bar (6000 PSI) 1 2345 Directional Turn

Controls Pressure 218 15 Cartridge Material All parts steel. All operating

parts hardened steel. Fully Open MV 145 10 Operating Temp. -40°C to +93.3°C (Nitrile) Manual Valves Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon) (Pressure Drop P) 73 5 (-25°F to +250°F) SV

Solenoid Fluid Mineral-based or synthetic with 0

Valves LPM 20 40 60 80 Compatibility/ lubricating properties at viscosities 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) GPM 5.3 10.6 15.9 21.2 Flow (Q) PV Filtration ISO Code 16/13,

Proportional High Pressure Drop vs. Flow 1 to 2 & 2 to 1 SAE Class 4 or better PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) Valves 5800 400 ½ Turn 1 1½ Approx. Weight .11 kg (.24 lbs.)

CE Cavity C08-2 4350 300 Electronics (See BC Section for more details) 2 Coils &

Form Tool Rougher None 2900 200 Finisher NFT08-2F BC

Pressure Drop (Pressure Drop P)

Bodies & 1450 100 3 Cavities

Fully Open 0 LPM 20 40 60 80 TD 0 GPM 5.3 10.6 15.9 21.2 Technical Flow (Q) Data

FC5 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series J02A2 CV Dimensions Millimeters (Inches) Check Valves SH 5 AF Hex socket

20.5 (0.81) Shuttle Valves max LM 17 AF Hex. 12 Nm (9 lb. ft.) Torque

22 22 AF Hex. Load/Motor Controls (0.87) 40 Nm (30 lb. ft.) FC Torque Flow Controls 3/4" - 16 UNF PC 27.2 (1.07) (2) Pressure Controls LE (1) Logic Elements DC

Ordering Information Directional Controls MV J02A2

08 Size Adjustment Seals Body Port Manual Valves Needle Valve Style Material Size SV

Code Adjustment Style Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Valves Solenoid Z Screw Adjust (Std.) N Nitrile, Buna-N (Std.)/ Omit Steel Omit Cartridge Only PV W Knob Adjust (SK30500N-1) A Aluminum 4P 1/4″ NPTF (B08-2-*4P) ″ T Tamper Resistant Cap V Fluorocarbon / 6P 3/8 NPTF (B08-2-*6P) (TC1130) (SK30500V-1) 4T SAE-4 (B08-2-*4T)

6T SAE-6 (B08-2-*6T) Proportional Valves ″ 6B 3/8 BSPG (B08-2-*6B) CE * Add “A” for aluminum, omit for steel. Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC6 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series NVH081 CV General Description FINE

Valves ADJUSTMENT Check Cartridge Style Needle Valve. For additional information see

SH Technical Tips on pages FC1-FC4.

Shuttle Valves Features LM Hardened, precision ground parts for durability

Load/Motor •

Controls Compact size for reduced space requirements • (2) • Fine adjustment needle option available for precise adjustment (1) FC • Polyurethane “D”-Ring eliminates backup rings and prevents hydrolysis Controls (1) (2) (2) COARSE Flow Valve meters flow in either direction, but (2 to 1) is the • ADJUSTMENT preferred direction for lowest leakage at shut off (1) PC • All external parts zinc plated Pressure Controls

LE Specifications Performance Curves Elements Flow vs. Inlet Pressure (Through cartridge only) Logic Rated Flow Fixed 37.9 LPM (10 GPM) Adjusted PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) 500 34.5 DC Coarse Directional Maximum Inlet 380 Bar (5500 PSI)

Controls Adjustment Pressure 400 27.6

Cartridge Material All parts steel. All operating parts hardened steel. 300 20.7 MV

1 Turn

Manual 2 Turns

Valves Operating Temp. -45°C to +93.3°C (“D”-Ring) 200 13.8 Range/Seals (-50°F to +200°F) -31.7°C to +121.1°C (Fluorocarbon) 3 Turns (-25°F to +250°F) (Pressure Drop P) SV 100 6.9 Full Open Solenoid Fluid Mineral-based or synthetic with Valves 0 Compatibility/ lubricating properties at viscosities LPM 7.6 15.1 22.7 30.3 37.9 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) GPM 2 4 6 8 10 Flow (Q) PV Proportional Filtration ISO Code 16/13, SAE Class 4 or better PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) Valves 500 34.5

Approx. Weight .10 kg (.20 lbs.) 400 27.6 CE

Electronics Cavity No. C08-2

1 Turn 2 Turns 3 Turns

Coils & (See BC Section for more details) 300 20.7 Full Open Form Tool Rougher None Finisher NFT08-2F 200 13.8 BC Fine Bodies & Cavities Pressure Drop (Pressure Drop P) Adjustment 100 6.9

0 TD LPM 7.6 15.1 22.7 30.3 37.9 0 Technical GPM 2 4 6 8 10 Flow (Q) Data

FC7 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series NVH081 CV Dimensions Millimeters (Inches) Check Valves SH 25.4 (1.0) Dia. Knob Shuttle Valves LM 42.4 36.6 36.6 (1.67) (1.44) (1.44) Load/Motor Controls FC

3/4-16 UNF-2A

Thread 7/8" Hex. Flow Controls 31-37 Nm 27.2 (23-27 lb. ft.) (1.07) PC (2) Torque (2) Pressure Controls (1) (1) 12.6 LE (.50) Screw/Knob Version Tamper Resistant Version

THIRD-ANGLE

PROJECTION Logic Elements DC

Ordering Information Directional Controls MV NVH081

08 Size Flow Adjustment Seals Body Port Manual Valves Needle Valve Needle Style Material Size SV

Code Flow Needle Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Omit Coarse Omit “D”-Ring / (SK08-2) Omit Steel Omit Cartridge Only

Valves Solenoid F Fine N Nitrile / (SK08-2N) A Aluminum 4P 1/4″ NPTF (B08-2-*4P) ″ PV V Fluorocarbon / 6P 3/8 NPTF (B08-2-*6P) Code Adjustment Style (SK08-2V) 4T SAE-4 (B08-2-*4T) 6T SAE-6 (B08-2-*6T) K Knob Adjust (717784-10) ″

6B 3/8 BSPG (B08-2-*6B) Proportional Valves S Screw Adjust * Add “A” for aluminum, omit for steel. T Tamper Resistant Cap (717943) CE Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC8 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series NVH101 CV General Description FINE Valves

Check ADJUSTMENT Cartridge Style Needle Valve. For additional information see Technical

SH Tips on pages FC1-FC4.

Shuttle Valves Features LM Hardened, precision ground parts for durability

Load/Motor •

Controls • Compact size for reduced space requirements (2) Fine adjustment needle option available for precise • (1) adjustment FC • Polyurethane “D”-Ring eliminates backup rings and prevents hydrolysis Controls (1) (2) Flow • Valve meters flow in either direction, but (2 to 1) is the (2) COARSE preferred direction for lowest leakage at shut off ADJUSTMENT (1) PC • All external parts zinc plated Pressure Controls

LE

Elements Specifications Performance Curves

Logic Flow vs. Inlet Pressure (Through cartridge only) Rated Flow Fixed 60 LPM (16 GPM) Adjusted 60 LPM (16 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) 500 34.5 DC

Directional Coarse

Controls Maximum Inlet 380 Bar (5500 PSI) Adjustment Pressure 400 27.6

Cartridge Material All parts steel. All operating MV parts hardened steel. 300 20.7 Manual

Valves 1 Turn 2 Turns Operating Temp. -45°C to +93.3°C (“D”-Ring) 200 13.8 3 Turns Range/Seals (-50°F to +200°F) -31.7°C to +121.1°C (Fluorocarbon) 4 Turns

Pressure Drop (Pressure Drop P) SV (-25°F to +250°F) 100 6.9

Solenoid Full Open Valves Fluid Mineral-based or synthetic with 0 Compatibility/ lubricating properties at viscosities LPM 7.6 15 23 30 38 45 53 61 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) GPM 2 4 6 8 10 12 14 16 PV Flow (Q) Proportional Filtration ISO Code 16/13, PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) Valves SAE Class 4 or better 500 34.5

1 Turn 6 Turns Approx. Weight .18 kg (0.4 lbs.) 3 Turns 4 Turns 5 Turns CE 400 27.6 Electronics Cavity C10-2 Coils & 2 Turns Full Open (See BC Section for more details) 300 20.7

Form Tool Rougher None BC Finisher NFT10-2F 200 13.8 Bodies & Cavities

Pressure Drop (Pressure Drop P) 100 6.9 Fine Adjustment TD 0 LPM 7.6 15 23 30 38 45 53 61 Technical 0 GPM 2 4 6 8 10 12 14 16

Data Flow (Q)

FC9 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series NVH101 CV Dimensions Millimeters (Inches) Check Valves

25.4 (1.0) SH Dia. Knob Shuttle Valves 41.9 LM 34.2 34.2 (1.65) (1.35) (1.35) Load/Motor Controls FC

7/8-14 UNF-2A 1" Hex. Thread 50-56 Nm Flow Controls 31.7 (37-41 lb. ft.) (1.25) PC Torque (2) (2) Pressure Controls (1) (1) Ø 15.8 LE (.62)

Screw/Knob Version Tamper Resistant Version THIRD-ANGLE

PROJECTION Logic Elements DC

Ordering Information Directional Controls MV NVH101

10 Size Flow Adjustment Seals Body Port Manual Valves Needle Valve Needle Style Material Size SV

Code Flow Needle Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Omit Coarse Omit “D”-Ring / (SK10-2) Omit Steel Omit Cartridge Only

Valves Solenoid F Fine N Nitrile / (SK10-2N) A Aluminum 4P 1/4″ NPTF (B10-2-*4P) ″ PV V Fluorocarbon / 6P 3/8 NPTF (B10-2-*6P) 8P 1/2″ NPTF (B10-2-*8P) Code Adjustment Style (SK10-2V) 6T SAE-6 (B10-2-*6T) K Knob Adjust (717784-10) 8T SAE-8 (B10-2-*8T) S Screw Adjust T8T SAE-8 (B10-2-T8T)† Proportional Valves T Tamper Resistant Cap (717943) 6B 3/8″ BSPG (B10-2-*6B) CE * Add “A” for aluminum, omit for steel. † Steel body only. Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC10 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series J06A2 CV General Description Valves Check Cartridge Style Needle Valve. For additional information see Technical Tips on pages FC1-FC4.

SH Shuttle Valves Features • Shuts off to a very low leakage level LM High flow capacity Load/Motor • Controls • Good adjustment sensitivity - ideal for fine control • Good contamination tolerant • Adjustable and tamperproof versions available (2) FC • All external parts zinc plated Controls (1) (2)

Flow (1)

PC Pressure Controls

LE

Elements Specifications Performance Curves (Through cartridge only)

Logic Low Pressure Drop vs. Flow 1 to 2 & 2 to 1 Rated Flow 225 LPM (60 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) 290 20 DC Maximum Inlet 420 Bar (6000 PSI) 1 2345 Directional Turn

Controls Pressure 218 15 Cartridge Material All parts steel. All operating parts hardened steel. MV 145 10 Operating Temp. -40°C to +93.3°C (Nitrile) Fully

Manual Open Valves Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon) (Pressure Drop P) 73 5 (-25°F to +250°F) SV

Solenoid Fluid Mineral-based or synthetic with 0

Valves LPM 50 100 150 200 250 300 Compatibility/ lubricating properties at viscosities 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) GPM 13.2 26.4 39.7 52.8 66.2 79.3 Flow (Q) PV Filtration ISO Code 16/13,

Proportional High Pressure Drop vs. Flow 1 to 2 & 2 to 1 SAE Class 4 or better PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) Valves 5800 400 Approx. Weight .38 kg (.84 lbs.)

CE Cavity C16-2 4350 300 Electronics (See BC Section for more details) Coils &

Form Tool Rougher None 2900 200

Finisher NFT16-2F 1 Turn BC

Pressure Drop (Pressure Drop P)

Bodies & 1450 100 Cavities 2 Turns

0 LPM 50 100 150 200 250 300 0 TD GPM 13.2 26.4 39.7 52.8 66.2 79.3 Technical Flow (Q) Data

FC11 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series J06A2 CV Dimensions Millimeters (Inches) Check Valves SH

22.35 5 AF Hex socket (0.88) max Shuttle Valves 17 AF Hex. LM 12 Nm (9 lb. ft.) Torque 25.50 38 AF Hex. Load/Motor Controls (1.00) 100 Nm (74 lb. ft.) FC Torque 1-5/16" - 12 UNF

46.75 Flow Controls (1.84) PC (2)

(1) Pressure Controls LE Logic Elements DC

Ordering Information Directional Controls J06A2 MV

16 Size Adjustment Seals Body Port Needle Valve Style Material Size Manual Valves SV

Code Adjustment Style Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Z Screw Adjust (Std.) N Nitrile, Buna-N (Std.)/ Omit Steel Omit Cartridge Only Valves W Knob Adjust (SK30507N-1) A Aluminum 12P 3/4″ NPTF (B16-2-*12P) Solenoid ″ T Tamper Resistant Cap V Fluorocarbon / 16P 1 NPTF (B16-2-*16P) PV (TC1130) (SK30507V-1) 8T SAE-8 (B16-2-*8T) 12T SAE-12 (B16-2-*12T) 16T SAE-16 (B16-2-*16T)

12B 3/4″ BSPG (B16-2-12B)† Proportional Valves ″ 16B 1 BSPG (B16-2-*16B) CE * Add “A” for aluminum, omit for steel. † Steel body only. Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC12 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series J02B2 CV General Description Valves Check Poppet Type Needle Valve with Reverse Flow Check. For additional information see Technical Tips on

SH pages FC1-FC4.

Shuttle Valves Features LM Shuts off to a very low leakage level

Load/Motor •

Controls • Good adjustment sensitivity - ideal for fine control • Good contamination tolerant • Adjustable and tamperproof versions available FC • All external parts zinc plated Controls (1) (2) (2) Flow

PC (1) Pressure Controls

LE

Elements Specifications Performance Curves (Through cartridge only)

Logic Low Pressure Drop vs. Flow 1 to 2 & 2 to 1 Rated Flow 30 LPM (8 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) 290 20 DC Maximum Inlet 420 Bar (6000 PSI) Directional 2¾ 2½ 2 Check Turns Open Controls Pressure 218 15 Cartridge Material All parts steel. All operating Fully parts hardened steel. Open MV 145 10 Operating Temp. -40°C to +93.3°C (Nitrile) Manual Valves Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon) (Pressure Drop P) 73 5 (-25°F to +250°F) SV

Solenoid Fluid Mineral-based or synthetic with 0

Valves LPM 5 10 15 20 25 30 Compatibility/ lubricating properties at viscosities 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) GPM 1.3 2.6 4.0 5.3 6.6 7.9 Flow (Q) PV Filtration ISO Code 16/13, High Pressure Drop vs. Flow 1 to 2 Proportional SAE Class 4 or better PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) Valves 5800 400 Approx. Weight .11 kg (.24 lbs.) 3 Turns

CE Cavity C08-2 4350 300 Electronics (See BC Section for more details) Coils &

Form Tool Rougher None 2900 200 Finisher NFT08-2F 2¾ BC Pressure Drop (Pressure Drop 1450 P) 100 Bodies &

Cavities 2½

Fully Open 0 LPM 5 10 15 20 25 30 0 TD GPM 1.3 2.6 4.0 5.3 6.6 7.9

Technical Flow (Q) Data

FC13 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series J02B2 CV Dimensions Millimeters (Inches) Check Valves

5 AF Hex socket SH

18.5 (0.73) 17 AF Hex. Shuttle Valves max 12 Nm LM (9 lb. ft.) Torque

22 AF Hex. 22 40 Nm Load/Motor Controls (0.87) (30 lb. ft.) FC Torque

3/4" - 16 UNF Flow Controls 27.2 PC (1.07) (2) Pressure Controls

(1) LE Logic Elements DC

Ordering Information Directional Controls J02B2 MV

08 Size Adjustment Seals Body Port Needle Valve Style Material Size Manual Valves SV

Code Adjustment Style Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Z Screw Adjust (Std.) N Nitrile, Buna-N (Std.)/ Omit Steel Omit Cartridge Only Valves W Knob Adjust (SK30500N-1) A Aluminum 4P 1/4″ NPTF (B08-2-*4P) Solenoid ″ T Tamper Resistant Cap V Fluorocarbon / 6P 3/8 NPTF (B08-2-*6P) PV (TC1130) (SK30500V-1) 4T SAE-4 (B08-2-*4T) 6T SAE-6 (B08-2-*6T) 6B 3/8″ BSPG (B08-2-*6B) * Add “A” for aluminum, omit for steel. Proportional Valves CE Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC14 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series FV101 and FV102 CV General Description Valves Check Needle Valve with a Reverse Check. Also known as a FV101 Flow . For additional information see

SH Technical Tips on pages FC1-FC4.

Shuttle Valves Features LM Hardened, precision ground parts for durability

Load/Motor •

Controls • Compact size for reduced space requirements Fine thread needle option available for precise (2) • Metered Flow adjustment Inlet FC All external parts zinc plated Free Flow • (2) (1) Outlet

Controls (1)

Flow Free Flow Inlet Metered Flow Outlet

PC Metered Flow Free Flow Pressure Controls

FV102 LE

Elements Specifications Free Flow

Logic Inlet (1) Rated Flow FV101 45 LPM (12 GPM) Metered FV102 23 LPM (6 GPM) Flow Outlet DC (2) Directional Metered Flow Inlet

Controls Maximum Inlet 210 Bar (3000 PSI) Free Flow Outlet Pressure

Cartridge Material All parts steel. All operating MV parts hardened steel. Manual Valves Operating Temp. -40°C to +93.3°C (Nitrile) Range/Seals (-40°F to +200°F) -31.7°C to +121.1°C (Fluorocarbon) Dimensions Millimeters (Inches) SV (-25°F to +250°F) Solenoid

Valves Fluid Mineral-based or synthetic with Screw and 38.1 (1.50) Compatibility/ lubricating properties at viscosities Knob Adjust - Dia. Knob Viscosity of 45 to 2000 SSU (6 to 420 cSt) 1/4" Internal Hex. PV Proportional Filtration ISO Code 16/13, 1" Hex. Valves 38.1 SAE Class 4 or better 22 Nm (1.50) (16 lb. ft.) Approx. Weight .23 kg (0.5 lbs.) Torque 18.8 (.74) CE

Electronics 7/8-14 UNF-2A Cavity C10-2 Thread Coils & (See BC Section for more details) 6.4 31.7 Form Tool Rougher None (.25) (1.25) BC Finisher NFT10-2F (2) Bodies & Cavities

(1) Ø 15.8 (.62) TD Technical Data

FC15 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Needle Valve Technical Information Series FV101 and FV102 CV Performance Curves Metered Flow vs. Pressure Drop (Through cartridge only)

PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) Check Valves 3000 204 3000 204 SH 1 2 2500 170 2500 170 1 FV101 3 2000 140 2000 140 Shuttle Valves 3.75 1500 105 1500 105 LM 2 1000 70 1000 70 4 5 FV102

Pressure Drop (Pressure Drop P) 500 35 3 (Pressure Drop P) 500 35 Load/Motor Controls 0 0 FC LPM 7.5 15.1 22.7 30.3 37.9 45.4 LPM 3.8 7.5 11.3 15.1 18.8 22.7 0 0 GPM 2 4 6 8 10 12 GPM 1 2 3 4 5 6 Flow (Q) Flow (Q) Flow Controls = No. of Turns CCW From Fully Closed. = No. of Turns CCW From Fully Closed. PC The number on each curve indicates the number of complete The number on each curve indicates the number of complete turns of the knob or screw adjustment from fully closed. turns of the knob or screw adjustment from fully closed (non- When the metered flow is 22.5 LPM (6 GPM) and the metered flow). When the metered flow is 7.5 LPM (2 GPM) adjustment is two complete turns from closed, the pressure and the adjustment is two complete turns from closed, the Pressure Controls drop will be 13.8 Bar (200 PSI). When the metered flow is pressure drop will be 156.9 Bar (2275 PSI). When the LE 22.5 LPM (6 GPM) and the adjustment is five complete turns metered flow is 7.5 LPM (2 GPM) and the adjustment is 3.75 from closed, the pressure drop will be 3.5 Bar (50 PSI). turns from closed, the pressure drop will be 56.6 Bar (820 PSI). Logic Elements DC

Ordering Information Directional Controls FV10 MV

10 Size Style Adjustment Seals Body Port Code Port Size Body Part No. Flow Control Valve Style Material Size Omit Cartridge Only Manual Valves 4P 1/4″ NPTF (B10-2-*4P) Code Style Code Seals / Kit. No. Code Body Material 6P 3/8″ NPTF (B10-2-*6P) SV 1 Coarse Flow Omit Nitrile / (SK10-2N) Omit Steel 8P 1/2″ NPTF (B10-2-*8P) 2 Fine Flow V Fluorocarbon / A Aluminum 6T SAE-6 (B10-2-*6T)

(SK10-2V) 8T SAE-8 (B10-2-*8T) Valves T8T SAE-8 (B10-2-T8T)† Solenoid Code Adjustment Style 6B 3/8″ BSPG (B10-2-6B)† PV K Knob Adjust (840208K) * Add “A” for aluminum, omit for steel. † Steel body only. S Screw Adjust Proportional Valves CE Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC16 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series J02E2 CV General Description Valves Check Restrictive Style, Pressure Compensated Flow Control Valve. For additional information see Technical Tips on

SH pages FC1-FC4.

Shuttle Valves Features LM Minimal flow change with pressure variation

Load/Motor •

Controls • Reverse flow function • Full adjustment from 1-20 LPM (0.3-5.3 GPM) • Hardened working parts for maximum durability FC • Adjustable and tamperproof versions available Controls All external parts zinc plated (1) (2)

Flow •

(2) PC Pressure Controls

(1) LE

Elements Specifications Performance Curves (Through cartridge only)

Logic Flow Regulating Performance Rated Flow 20 LPM (5.3 GPM) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) 5.3 20 DC Maximum Inlet 420 Bar (6000 PSI) Directional

Controls Pressure 4.0 15 Cartridge Material All parts steel. All operating parts hardened steel. MV 2.6 10 Operating Temp. -40°C to +93.3°C (Nitrile) Manual Valves Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon) Regulated Flow 1.3 5 (-25°F to +250°F) SV

Solenoid Fluid Mineral-based or synthetic with 0

Valves Bar 100 200 300 400 Compatibility/ lubricating properties at viscosities 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) PSI 1450 2900 4350 5800 Pressure Drop PV Filtration ISO Code 16/13, Reverse Flow Pressure Drop vs. Flow Proportional SAE Class 4 or better PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Valves 290 20 Approx. Weight .13 kg (.29 lbs.)

CE Cavity C08-2 218 15 Electronics (See BC Section for more details) Coils &

Form Tool Rougher None 145 10 Finisher NFT08-2F BC Pressure Drop (Pressure Drop P) 73 5 Bodies & Cavities

0 LPM 5 10 15 20 0 TD GPM 1.3 2.6 4.0 5.3

Technical Flow (Q) Data

FC17 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series J02E2 CV Dimensions Millimeters (Inches)

5 AF Hex socket Check Valves SH Rotate adjuster 20 CW to increase flow (0.79) or CCW to decrease flow.

max Shuttle Valves 17 AF Hex. LM 12 Nm (9 lb. ft.) Torque

22 AF Hex. Load/Motor Controls 32.7 40 Nm (1.29) (30 lb. ft.) FC Torque Flow Controls PC 3/4" - 16 UNF 27.7 (1.09) (2) Pressure Controls LE

(1) Logic Elements DC

Ordering Information Directional Controls J02E2 MV

08 Size Adjustment Optional Seals Body Port Pressure Style Flow Material Size

Compensated Flow Setting Manual Valves Control Valve SV

Code Adjustment Style Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Z Screw Adjust (Std.) N Nitrile, Buna-N (Std.)/ Omit Steel Omit Cartridge Only Valves W Knob Adjust (SK30500N-1) A Aluminum 4P 1/4″ NPTF (B08-2-*4P) Solenoid ″ T Tamper Resistant Cap V Fluorocarbon / 6P 3/8 NPTF (B08-2-*6P) PV (TC1130) (SK30500V-1) 4T SAE-4 (B08-2-*4T) 6T SAE-6 (B08-2-*6T) ″ Code Optional Flow Setting 6B 3/8 BSPG (B08-2-*6B) Proportional Valves Omit Omit for no setting* * Add “A” for aluminum, omit for steel. CE Specify setting if required (LPM) * Appropriate mid-range setting for Standard = 10 LPM Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC18 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Regulator Valve Technical Information Series FR101 CV General Description Valves Check Pressure Compensated Flow Regulator Valve. NOTE: When used with a fixed displacement pump, SH pressure to the cartridge must be controlled by a relief

valve located between the pump and the FR101 Shuttle Valves cartridge. For additional information see Technical Tips on pages FC1-FC4.

LM Load/Motor Features Controls • Hardened, precision ground parts for durability • Cartridge design • Acts as a fixed orifice in reverse flow condition FC Inlet Outlet • All external parts zinc plated (1) (2) Controls

Flow Reg. (2)

PC Adjustable Style Inlet (1) Pressure Controls

LE Specifications Performance Curves Elements Regulated Flow vs. Pressure Logic Rated Flow Fixed 22.5 LPM (6 GPM) (Through cartridge only) Adjusted 26.5 LPM (7 GPM) DC GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Directional Maximum Inlet 245 Bar (3500 PSI) 7 26.3

Controls Pressure 6 22.5 22.5 LPM (6 GPM) Fixed 16.7 LPM (4.45 GPM) Adjustable (Max. Range) Accuracy (Fixed) 3.8 LPM (1 GPM) ±20% 5 18.8 7.5 - 11.3 LPM (2-3 GPM) ±15% MV 15 - 22.5 LPM (4-6 GPM) ±10% 4 15.0 16.7 LPM (4.45 GPM) Manual Valves 11.3 LPM (3 GPM) Fixed Adjustable (Min. Range) Adjustment Range ±30% Nominal 3 11.3 (Adj. Version)

Regulated Flow 2 7.5 SV Cartridge Material All parts steel. All operating 3.8 LPM (1 GPM) Fixed Solenoid parts hardened steel. 1 3.8 Valves 0 Bar 68 138 207 Operating Temp. -40°C to +93.3°C (Nitrile) 0 Range/Seals (-40°F to +200°F) PSI 1000 2000 3000 PV Inlet Pressure Proportional -31.7°C to +121.1°C (Fluorocarbon) (-25°F to +250°F) Valves GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) 7 26.3 Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities 6 22.5 CE

Electronics Viscosity of 45 to 2000 SSU (6 to 420 cSt) 5 18.8 Coils & Filtration ISO Code 16/13, SAE Class 4 or better 4 15.0 3 11.3 BC Approx. Weight .23 kg (0.5 lbs.) Bodies &

Regulated Flow Cavities 2 7.5 Cavity No. C10-2 (See BC Section for more details) 1 3.8 TD 0 Form Tool Rougher None Bar 7 14 22 28 35 42 Technical 0 Finisher NFT10-2F PSI 100 200 300 400 500 600

Data Minimum Operating Pressure

FC19 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Regulator Valve Technical Information Series FR101 CV Dimensions Millimeters (Inches)

Screw and Fixed Style Check Valves Knob Adjust - SH 1/4" Internal Hex. 25.4 (1.0) Rotate adjuster Dia. Knob CW to increase flow or CCW to decrease flow. Shuttle Valves LM 78.1 (3.08) 1" Hex. 55.1 1" Hex. 22 Nm (2.17) 21.9 22 Nm Load/Motor Controls (16 lb. ft.) (.85) Torque (16 lb. ft.) Torque FC

7/8-14 UNF-2A 7/8-14 UNF-2A 6.4 Thread Thread (.25) Flow Controls 31.8 Outlet (1.25) Outlet PC (2) (2)

Inlet Inlet (1) Pressure Controls Ø 15.8 (1) THIRD-ANGLE (.62) PROJECTION LE Logic Elements Ordering Information DC FR101

10 Size Adjustment Flow Optional Seals Body Port Directional Controls Pressure Style Setting/ Setting Material Size MV Compensated Flow Range Regulator (Restrictive) Manual Valves

Code Adjustment Style Code Fixed Style Flow Optional Setting Code Seals / Kit. No. SV F Fixed Style present 100 3.8 LPM (1 GPM) Flow setting specified in Omit Nitrile / (SK10-2N) at factory 200 7.5 LPM (2 GPM) .38 LPM (.1 GPM) increments V Fluorocarbon / other than standard

K Knob Adjust 300 11.3 LPM (3 GPM) (SK10-2V)

Valves Solenoid S Screw Adjust 400 15 LPM (4 GPM) Code Body Material PV 500 18.8 LPM (5 GPM) Omit Steel 600 22.5 LPM (6 GPM) A Aluminum Proportional Valves Code Knob/Screw Style Flow Range Code Port Size Body Part No. CE 065 1.9-3.0 LPM (0.5-0.8 GPM) Omit Cartridge Only 095 3.0-4.5 LPM (0.8-1.2 GPM) 4P 1/4″ NPTF (B10-2-*4P) 135 4.1-6.4 LPM (1.1-1.7 GPM) 6P 3/8″ NPTF (B10-2-*6P) 8P 1/2″ NPTF (B10-2-*8P) 185 6.0-8.3 LPM (1.6-2.2 GPM) Coils & Electronics 260 7.9-11.6 LPM (2.1-3.1 GPM) 6T SAE-6 (B10-2-*6T) 8T SAE-8 (B10-2-*8T) BC 375 11.3-16.9 LPM (3.0-4.5 GPM) T8T SAE-8 (B10-2-T8T)† 550 16.1-25.1 LPM (4.3-6.7 GPM) 6B 3/8″ BSPG (B10-2-6B)†

* Add “A” for aluminum, omit for steel. Cavities † Steel body only. & Bodies TD Technical Data

FC20 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series J04E2 CV General Description Valves Check Restrictive Style, Pressure Compensated Flow Control Valve. For additional information see Technical Tips on

SH pages FC1-FC4.

Shuttle Valves Features LM Minimal flow change with pressure variation

Load/Motor •

Controls • Reverse flow function • Full adjustment from 1-40 LPM (0.3-10.6 GPM) • Hardened working parts for maximum durability FC Adjustable and tamperproof versions available Inlet Outlet • (1) (2) Controls All external parts zinc plated

Flow •

PC Adjustable Style (2) Pressure Controls

(1)

LE

Elements Specifications Performance Curves (Through cartridge only)

Logic Flow Regulating Performance Rated Flow 40 LPM (10.6 GPM) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) 10.6 40 DC Maximum Inlet 420 Bar (6000 PSI) Directional

Controls Pressure 7.9 30 Cartridge Material All parts steel. All operating parts hardened steel. MV 5.3 20 Operating Temp. -40°C to +93.3°C (Nitrile) Manual Valves Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon) Regulated Flow 2.6 10 (-25°F to +250°F) SV

Solenoid Fluid Mineral-based or synthetic with 0

Valves Bar 100 200 300 400 Compatibility/ lubricating properties at viscosities 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) PSI 1450 2900 4350 5800 Pressure Drop PV Filtration ISO Code 16/13, Reverse Flow Pressure Drop vs. Flow Proportional SAE Class 4 or better PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) Valves 290 20 Approx. Weight .20 kg (.44 lbs.)

CE Cavity C10-2 218 15 Electronics (See BC Section for more details) Coils &

Form Tool Rougher None 145 10 Finisher NFT10-2F BC

Pressure Drop (Pressure Drop P)

Bodies & 73 5 Cavities

0 LPM 10 20 30 40 0 TD GPM 2.6 5.3 7.9 10.6 Technical Flow (Q) Data

FC21 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series J04E2 CV Dimensions Millimeters (Inches) Check Valves 5 AF Hex socket SH Rotate adjuster 22 CW to increase flow (0.87) or CCW to decrease flow. max Shuttle Valves 17 AF Hex. LM 12 Nm (9 lb. ft.) Torque

26 AF Hex. Load/Motor Controls 39.5 50 Nm FC (1.56) (37 lb. ft.) Torque Flow Controls PC 7/8" - 14 UNF 31.8 (1.25) Pressure Controls (2) LE

(1) Logic Elements DC

Ordering Information Directional Controls J04E2 MV

10 Size Adjustment Optional Seals Body Port Pressure Style Flow Material Size

Compensated Flow Setting Manual Valves Control Valve SV

Code Adjustment Style Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Z Screw Adjust (Std.) N Nitrile, Buna-N (Std.)/ Omit Steel Omit Cartridge Only Valves W Knob Adjust (SK30500N-1) A Aluminum 4P 1/4″ NPTF (B10-2-*4P) Solenoid ″ T Tamper Resistant Cap V Fluorocarbon / 6P 3/8 NPTF (B10-2-*6P) PV ″ (TC1130) (SK30500V-1) 8P 1/2 NPTF (B10-2-*8P) 6T SAE-6 (B10-2-*6T) 8T SAE-8 (B10-2-*8T) Code Optional Flow Setting

T8T SAE-8 (B10-2-T8T)† Proportional Valves Omit Omit for no setting* ″ 6B 3/8 BSPG (B10-2-6B)† CE Specify setting if * Add “A” for aluminum, omit for steel. required (LPM) † Steel body only. * Appropriate mid-range setting for Standard = 20 LPM Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC22 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series J04C2 CV General Description Valves Check Restrictive Variable Orifice Style, Pressure Compen- sated Flow Control Valve. For additional information

SH see Technical Tips on pages FC1-FC4.

Shuttle Valves Features LM Minimal flow change with pressure variation

Load/Motor •

Controls • Partial reverse flow capability • Full adjustment from 1-40 LPM (0.3-10.6 GPM) • Hardened working parts for maximum durability (2) FC Adjustable and tamperproof versions available Inlet Outlet • (1) (2) Controls All external parts zinc plated

Flow •

(1) PC Adjustable Style Pressure Controls

LE

Elements Specifications Performance Curves (Through cartridge only)

Logic Flow Regulating Performance 2 to 1 Rated Flow 40 LPM (10.6 GPM) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) 10.6 40 DC Maximum Inlet 420 Bar (6000 PSI) Directional

Controls Pressure 7.9 30 Cartridge Material All parts steel. All operating parts hardened steel. MV 5.3 20 Operating Temp. -40°C to +93.3°C (Nitrile) Manual Valves Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon) Regulated Flow 2.6 10 (-25°F to +250°F) SV

Solenoid Fluid Mineral-based or synthetic with 0

Valves Bar 100 200 300 400 Compatibility/ lubricating properties at viscosities 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) PSI 1450 2900 4350 5800 Pressure Drop PV Filtration ISO Code 16/13,

Proportional Reverse Flow Pressure Drop vs. Flow 2 to 1 SAE Class 4 or better PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) Valves 580 40 Approx. Weight .15 kg (.33 lbs.)

CE Cavity C10-2 435 30 Electronics (See BC Section for more details) Coils &

Form Tool Rougher None 290 20 Finisher NFT10-2F BC 2 LPM Setting

Pressure Drop (Pressure Drop P)

Bodies & 145 10 Cavities 20 LPM Setting 40 LPM Setting

0 LPM 10 20 30 40 TD 0 GPM 2.6 5.3 7.9 10.6 Technical Flow (Q) Data

FC23 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series J04C2 CV Dimensions Millimeters (Inches) Check Valves SH 14.75 (0.58) max 5 AF Hex socket Rotate adjuster CW to decrease flow Shuttle Valves or CCW LM to increase flow.

17 AF Hex. 20 12 Nm (9 lb. ft.)

(0.79) Torque Load/Motor Controls 26 AF Hex. FC 50 Nm (37 lb. ft.) Torque 7/8" - 14 UNF 33 (2) Flow Controls (1.30) PC Pressure Controls (1) LE Logic Elements DC

Ordering Information Directional Controls J04C2 MV

10 Size Adjustment Optional Seals Body Port Pressure Style Flow Material Size

Compensated Flow Setting Manual Valves Control Valve SV

Code Adjustment Style Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Z Screw Adjust (Std.) N Nitrile, Buna-N (Std.)/ Omit Steel Omit Cartridge Only Valves W Knob Adjust (SK30503N-1) A Aluminum 4P 1/4″ NPTF (B10-2-*4P) Solenoid ″ T Tamper Resistant Cap V Fluorocarbon / 6P 3/8 NPTF (B10-2-*6P) PV ″ (TC1130) (SK30503V-1) 8P 1/2 NPTF (B10-2-*8P) 6T SAE-6 (B10-2-*6T) 8T SAE-8 (B10-2-*8T) Code Optional Flow Setting

T8T SAE-8 (B10-2-T8T)† Proportional Valves Omit Omit for no setting* ″ 6B 3/8 BSPG (B10-2-6B)† CE Specify setting if * Add “A” for aluminum, omit for steel. required (LPM) † Steel body only. * Appropriate mid-range setting for Standard = 20 LPM Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC24 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series FA101 CV General Description Valves Check Fully Adjustable, Pressure Compensated Flow Control Valve. For additional information see Technical Tips on

SH pages FC1-FC4.

Shuttle Valves Features LM Fully adjustable from 0.75 LPM (0.2 GPM) to 20.6 LPM

Load/Motor •

(5.5 GPM) Controls Hardened, precision ground parts for durability • (2) • All external parts are finished in yellow zinc dichromate. Metered Flow This enables them to withstand a 200 hour salt spray test. Outlet FC Free Flow Compact size for reduced space requirements (1) (2) Inlet Controls • Flow

(1) PC Pressure Controls

LE

Elements Specifications Performance Curves

Logic Regulated Flow vs. Pressure Drop Rated Flow 0.75 LPM (0.2 GPM) (Through cartridge only) 20.6 LPM (5.5 GPM) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) DC 623 Directional

Controls Maximum Inlet 210 Bar (3000 PSI) Pressure 5 19

Cartridge Material All parts steel. All operating MV parts hardened steel. 4 15 Manual Valves Operating Temp. -40°C to +93.3°C (Nitrile) 3 11 Range/Seals (-40°F to +200°F) -31.7°C to +121.1°C (Fluorocarbon) 2 7.6

Regulated Flow SV (-25°F to +250°F)

Solenoid 1 3.8 Valves Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities 0 Bar 35 70 105 140 175 210 Viscosity of 45 to 2000 SSU (6 to 420 cSt) 0 PV PSI 500 1000 1500 2000 2500 3000 Proportional Pressure Drop ( P) Filtration ISO Code 16/13,

Valves SAE Class 4 or better

Approx. Weight .23 kg (0.5 lbs.) CE Electronics Cavity C10-2 Coils & (See BC Section for more details)

Form Tool Rougher None BC Finisher NFT10-2F Bodies & Cavities

TD Technical Data

FC25 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series FA101 CV Dimensions Millimeters (Inches) Check Valves Detented Knob SH 4.8 (.19) Tamper Resistant Cap Hollow Hex. 25.4 (1.0) Dia. Knob Shuttle Valves LM Rotate adjuster CW to decrease 54.2 flow or CCW (2.13) 1.61 to increase flow. 34.6 (40.9) (1.36) Load/Motor Controls FC 1" Hex. 22 Nm (16 lb. ft.) Torque Flow Controls PC 31.8 (2) 7/8-14 UNC-2A (2) (1.25) Thread Pressure Controls (1) (1) LE Ø 15.8 (.622) Ø 15.7 (.620) THIRD-ANGLE PROJECTION Logic Elements DC

Ordering Information Directional Controls FA101 MV

10 Size Adjustment Seals Body Port Pressure Style Material Size

Compensated Flow Manual Valves Control Valve SV

Code Adjustment Style Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

D Detented Knob Omit Nitrile / (SK10-2N) Omit Steel Omit Cartridge Only Valves K Knob Adjust (717784-10) V Fluorocarbon / A Aluminum 4P 1/4″ NPTF (B10-2-*4P) Solenoid ″ S Screw Adjust (SK10-2V) 6P 3/8 NPTF (B10-2-*6P) PV 8P 1/2″ NPTF (B10-2-*8P) T Tamper Resistant Cap (717785) 6T SAE-6 (B10-2-*6T) 8T SAE-8 (B10-2-*8T)

T8T SAE-8 (B10-2-T8T)† Proportional Valves ″ 6B 3/8 BSPG (B10-2-*6B) CE * Add “A” for aluminum, omit for steel. † Steel body only. Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC26 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series FC101 CV General Description Valves Check Pressure Compensated Flow Control. For additional information see Technical Tips on pages FC1-FC4.

SH Shuttle Valves Features • Hardened, precision ground parts for durability LM Compact size for reduced space requirements Load/Motor • Controls • Free flow in reverse condition • All external parts zinc plated (2) FC Metered Flow (1) (2) Outlet Controls Free Flow

Flow Inlet (1) Full Flow Outlet PC Metered Flow Inlet Pressure Controls

LE Specifications Performance Curves Elements

Logic Regulated Flow vs. Pressure Drop Rated Flow 20.6 LPM (5.5 GPM) (Through cartridge only) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) DC 830

Directional Maximum Inlet 210 Bar (3000 PSI)

Controls Pressure

6 23 600 Cartridge Material All parts steel. All operating parts hardened steel. 500 MV 4 15 400 Manual

Valves Operating Temp. -40°C to +93.3°C (Nitrile) Range/Seals (-40°F to +200°F) 300

-31.7°C to +121.1°C (Fluorocarbon) Regulated Flow 2 8 200 (-25°F to +250°F) SV 100 050 Solenoid Fluid Mineral-based or synthetic with 0 Valves Bar 35 70 105 140 170 204 Compatibility/ lubricating properties at viscosities 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) PSI 500 1000 1500 2000 2500 3000 Pressure Drop ( P) PV Proportional Filtration ISO Code 16/13, Pressure Drop vs. Flow (Through cartridge only) SAE Class 4 or better Valves PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) 250 18 Approx. Weight .23 kg (0.5 lbs.)

CE 200 14 Electronics Cavity C10-2

Coils & (See BC Section for more details) 150 11 Form Tool Rougher None Finisher NFT10-2F BC 100 7 Bodies & Cavities

Pressure Drop (Pressure Drop P) 50 4

0 TD LPM 8 15 23 30 0 Technical GPM 2 4 6 8 Flow (Q) Data

FC27 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Flow Control Valve Technical Information Series FC101 CV Dimensions Millimeters (Inches) Check Valves Screw and SH Knob Adjust - 1/4" Internal Hex. Tamper Resistant Rotate adjuster 38.1 (1.50) CW to increase Dia. Knob Shuttle Valves flow or CCW LM to decrease flow. 58.4 61.0 (2.30) (2.40) Max. 35.6

(1.40) Load/Motor Controls FC

1" Hex.

7/8-14 UNF-2A 22 Nm Flow Controls Thread (16 lb. ft.) Torque 31.8 PC (1.25) (2) Metered Flow Outlet

Free Flow Inlet Pressure Controls

(1) LE Full Flow Outlet Ø 15.8 (.62) THIRD-ANGLE Metered Flow Inlet PROJECTION Logic Elements DC

Ordering Information Directional Controls FC101 MV

10 Size Adjustment Flow Optional Seals Body Port Pressure Style Range Setting Material Size

Compensated Flow Manual Valves Control SV

Code Adjustment Style Optional Setting Code Body Material

K Knob Adjust (840208K) Flow setting specified in Omit Steel Valves S Screw Adjust .38 LPM (.1 GPM) increments A Aluminum Solenoid other than standard T Tamper Resistant Cap (717783) PV

Code Flow Range and Code Seals / Kit. No. Code Port Size Body Part No. Proportional Valves Standard Setting Omit Nitrile / (SK10-2N) Omit Cartridge Only CE 050 1.1-3.8 LPM (.30-1.0 GPM) V Fluorocarbon / 4P 1/4″ NPTF (B10-2-*4P) (1.9 LPM (.5 GPM) @ (SK10-2V) 6P 3/8″ NPTF (B10-2-*6P) ∆ 69 Bar (1000 PSI) P) 8P 1/2″ NPTF (B10-2-*8P) 100 2.8-8.3 LPM (.75-2.2 GPM) 6T SAE-6 (B10-2-*6T) Coils & Electronics (3.8 LPM (1 GPM) @ 8T SAE-8 (B10-2-*8T) ∆ 69 Bar (1000 PSI) P) T8T SAE-8 (B10-2-T8T)† BC 300 7.5-16.9 LPM (2.0-4.5 GPM) 6B 3/8″ BSPG (B10-2-6B)† (11.3 LPM (3 GPM) @ 69 Bar (1000 PSI) ∆P) * Add “A” for aluminum, omit for steel.

† Steel body only. Cavities 600 15-30 LPM (4.0-8.0 GPM) & Bodies (22.5 LPM (6 GPM) @ TD 69 Bar (1000 PSI) ∆P) Technical Data

FC28 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Priority Flow Control Valve Technical Information Series J02D3 CV General Description Valves Check Needle Type, Pressure Compensated Flow Regulator Valve. For additional information see Technical Tips on

SH pages FC1-FC4.

Shuttle Valves Features LM Good adjustment from 1-15 LPM (0.3-4 GPM)

Load/Motor •

Controls • Used for systems requiring priority flow such as steering systems Hardened working parts for maximum durability • (3) FC • Reverse flow function 3 to 1 (1) (3) Controls • Adjustable and tamperproof versions available Flow • All external parts zinc plated (2) PC (2) Pressure Controls (1)

LE

Elements Specifications Performance Curves (Through cartridge only)

Logic Flow Regulating Performance Rated Flow 15 LPM (4 GPM) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) 5.3 20 DC Maximum Inlet 420 Bar (6000 PSI) INLET FLOW 20 LPM (5.3 GPM) Directional

Controls Pressure 4.0 15 Cartridge Material All parts steel. All operating parts hardened steel. MV 2.6 10 Operating Temp. -40°C to +93.3°C (Nitrile) Manual Valves Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon) Regulated Flow 1.3 5 (-25°F to +250°F) SV

Solenoid Fluid Mineral-based or synthetic with 0 Bypass 2 > Regulated 3 Regulated 3 > Bypass 2 Valves Compatibility/ lubricating properties at viscosities Bar 400 200 200 400 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) PSI 5800 2900 2900 5800 Pressure Drop PV Filtration ISO Code 16/13, Proportional SAE Class 4 or better Valves Application Approx. Weight .08 kg (.18 lbs.)

CE Cavity C08-3 Electronics (See BC Section for more details) Coils & OTHER Form Tool Rougher NFT08-3R SERVICES Finisher NFT08-3F BC Priority flow on steering circuit Bodies & Cavities

TD Technical Data

FC29 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Priority Flow Control Valve Technical Information Series J02D3 CV Dimensions Millimeters (Inches) Check Valves 5 AF Hex socket SH Rotate adjuster 20.5 CW to decrease flow (0.81) or CCW max

to increase flow. Shuttle Valves

17 AF Hex. LM 12 Nm (9 lb. ft.) 22 Torque (0.87)

22 AF Hex. Load/Motor Controls 40 Nm (30 lb. ft.) FC Torque

3/4" - 16 UNF Flow Controls (3) PC 41.2 (1.62)

(2) Pressure Controls LE

(1) Logic Elements DC

Ordering Information Directional Controls J02D3 MV

Pressure Adjustment Optional Seals Body Port Compensated Style Flow Material Size

Priority Flow Setting Manual Valves Control Valve SV

Code Adjustment Style Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Z Screw Adjust (Std.) N Nitrile, Buna-N (Std.)/ Omit Steel Omit Cartridge Only Valves W Knob Adjust (SK30501N-1) A Aluminum 4P 1/4″ NPTF (B08-3-*4P) Solenoid T Tamper Resistant Cap V Fluorocarbon / 4T SAE-4 (B08-3-*4T) PV (TC1130) (SK30501V-1) 6T SAE-6 (B08-3-*6T) 6B 3/8″ BSPG (B08-3-*6B) Code Optional Flow Setting * Add “A” for aluminum, omit for steel. Proportional Valves Omit Omit for no setting* CE Specify setting if required (LPM) * Appropriate mid-range setting for Standard = 7 LPM Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC30 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Priority Flow Regulator Valve Technical Information Series FP101 CV General Description Valves Check Pressure Compensated Priority Flow Regulator Valve. For additional information see Technical Tips on pages SH FC1-FC4.

Shuttle Caution: If the priority line is blocked so that no flow Valves can pass through the control orifice; the compensator spool will shift, blocking the bypass port and allowing LM inlet pressure to go to full system relief pressure. The

Load/Motor FP101 cartridge does not provide a pressure relieving Controls function.

Priority FC (3) (1) (3)

Controls Bypass (2) Flow Specifications (2) Inlet PC (1) Pressure

Controls Maximum Fixed 30.0 LPM (8 GPM) Priority Flow Adjusted 33.8 LPM (9 GPM)

Maximum 56.3 LPM (15 GPM) Features LE Inlet Flow Hardened, precision ground parts for durability

Elements •

Logic Minimum See Valve Performance Curves • Cartridge design Inlet Flow • Acts as a fixed orifice in reverse flow condition (Priority line only) DC Maximum 245 Bar (3500 PSI) Directional • All external parts zinc plated Controls Inlet Pressure

Minimum See Valve Performance Curves Inlet Pressure Dimensions Millimeters (Inches) MV 38.1 (1.50) Accuracy (Fixed) ±20% Screw and Manual

Valves Dia. Knob Knob Adjust - Adjustment Range ±20% Nominal 1/4" Hollow Hex. (Adj. Version) Rotate adjuster CW SV to increase priority flow or CCW to Solenoid Cartridge Material All parts steel. All operating decrease priority flow. Valves parts hardened steel. 85.3 (3.36) Fixed Style Operating Temp. -40°C to +93.3°C (Nitrile) 1" Hex. 52.8 PV 22 Nm (2.08) 21.8 Proportional Range/Seals (-40°F to +200°F) (16 lb. ft.) (.86) -31.7°C to +121.1°C (Fluorocarbon) Torque Valves (-25°F to +250°F) 7/8- 14 UNF-2A Fluid Mineral-based or synthetic with Thread CE Compatibility/ lubricating properties at viscosities Electronics 1" Hex. Viscosity of 45 to 2000 SSU (6 to 420 cSt) 22 Nm Coils & Priority 46.2 (16 lb. ft.) (3) Filtration ISO Code 16/13, (1.82) Torque SAE Class 4 or better Bypass 7/8- BC (2) 14 UNF-2A Thread Bodies & Cavities Approx. Weight .23 kg (0.5 lbs.) Inlet (1) Inlet Cavity No. C10-3 15.8 (1) (.62) (See BC Section for more details) 17.4 TD (.68) Technical

Form Tool Regulator NFT10-3R THIRD-ANGLE PROJECTION Data Finisher NFT10-3F

FC31 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Priority Flow Regulator Valve Technical Information Series FP101 CV Performance Curves (Through cartridge only) Pressure vs. Priority Flow Regulated Flow vs. Load Pressure Minimum Operating Pressure

GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) Check Valves 8 30.0 10 37.5 SH

8 30.0 6 22.5

6 22.5 Shuttle Valves 4 15.0 LM 4 15.0

Flow (Q) Flow

Priority Flow 2 7.5 2 7.5 Load/Motor Controls 0 0 FC Bar 35 70 105 140 175 210 Bar 13.8 27.6 41.4 55.2 0 0 PSI 500 1000 1500 2000 2500 3000 PSI 200 400 600 800 Load Pressure Minimum Operating Pressure Load on Bypass Port - Bar Load on Priority Port - Bar Flow Controls Minimum Inlet Flow Inlet Flow vs. Regulated Flow PC GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) 10 37.5 10 37.5 Fixed Style 800 8 30.0 8 30.0 Pressure Controls 700 LE 600 6 22.5 6 22.5 500

400 4 15.0 4 15.0 Inlet Flows 300 Logic Elements

Regulated Flow Regulated Flow 200 2 7.5 2 7.5 DC 100

0 0 LPM 7.5 15 22.5 30 37.5 45 52.5 60 LPM 7.5 15 22.5 30 37.5 45 52.5 60 0 0 GPM 2 4 6 8 10 12 14 16 GPM 2 4 6 8 10 12 14 16 Directional Controls Minimum Inlet Flow (Shaded Area) Inlet Flow MV

Ordering Information Manual Valves SV FP101

10 Size Adjustment Flow Seals Body Port

Pressure Style Setting/ Material Size

Valves Solenoid Compensated Flow Range Regulator PV

Code Adjustment Style Code Fixed Style Flow Code Knob/Screw Style Flow Range Code Body Material

F Fixed Style present 100 3.8 LPM (1 GPM) 085 2.6-3.8 LPM (0.7-1.0 GPM) Omit Steel Proportional Valves at factory 200 7.5 LPM (2 GPM) 110 3.0-5.3 LPM (0.8-1.4 GPM) A Aluminum CE K Knob Adjust 300 11.3 LPM (3 GPM) 155 4.5-7.1 LPM (1.2-1.9 GPM) S Screw Adjust 400 15 LPM (4 GPM) 220 6.4-10.1 LPM (1.7-2.7 GPM) Code Port Size Body Part No. 500 18.8 LPM (5 GPM) 295 8.6-13.5 LPM (2.3-3.6 GPM) Omit Cartridge Only 600 22.5 LPM (6 GPM) 405 11.6-18.8 LPM (3.1-5.0 GPM) 4P 1/4″ NPTF (B10-3-*4P) Coils & Electronics ″ 700 26.3 LPM (7 GPM) 575 16.9-26.3 LPM (4.5-7.0 GPM) 6P 3/8 NPTF (B10-3-*6P) BC 8P 1/2″ NPTF (B10-3-*8P) 800 30 LPM (8 GPM) 780 23.6-34.9 LPM (6.3-9.3 GPM) 6T SAE-6 (B10-3-*6T)

8T SAE-8 (B10-3-*8T) Cavities Code Seals / Kit. No. 6B 3/8″ BSPG (B10-3-6B)† & Bodies Omit Nitrile / (SK10-3N) 8B 1/2″ BSPG (B10-3-*8B) TD V Fluorocarbon / (SK10-3V) * Add “A” for aluminum, omit for steel. † Steel body only. Technical Data

FC32 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Priority Flow Control Valve Technical Information Series J04D3 CV General Description Valves Check Priority Type, Pressure Compensated Flow Regulator Valve. For additional information see Technical Tips on

SH pages FC1-FC4.

Shuttle Valves Features LM High flow capacity

Load/Motor •

Controls • Good adjustment from 2-45 LPM (0.5-12 GPM) • Used for systems requiring priority flow such as steering systems (3) FC Hardened working parts for maximum durability • (1) (3) Controls • Reverse flow function 3 to 1 Flow • Adjustable and tamperproof versions available (2) All external parts zinc plated • (2) PC Pressure

Controls (1)

LE

Elements Specifications Performance Curves (Through cartridge only)

Logic Flow Regulating Performance Rated Flow 45 LPM (12 GPM) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) 13.2 50 DC Maximum Inlet 420 Bar (6000 PSI) INLET FLOW 70 LPM (18.5 GPM) Directional

Controls Pressure 10.6 40 Cartridge Material All parts steel. All operating parts hardened steel. 7.9 30 MV Operating Temp. -40°C to +93.3°C (Nitrile)

Manual 5.3 20 Valves Range/Seals (-40°F to +200°F)

-31.7°C to +121.1°C (Fluorocarbon) Regulated Flow (-25°F to +250°F) 2.6 10 SV

Solenoid Fluid Mineral-based or synthetic with 0 Bypass 2 > Regulated 3 Regulated 3 > Bypass 2 Valves Compatibility/ lubricating properties at viscosities Bar 400 200 200 400 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) PSI 5800 2900 2900 5800 Pressure Drop PV Filtration ISO Code 16/13, Proportional SAE Class 4 or better Valves Application Approx. Weight .18 kg (.40 lbs.)

CE Cavity C10-3 Electronics (See BC Section for more details) Coils & OTHER Form Tool Rougher NFT10-3R SERVICES Finisher NFT10-3F BC Priority flow on steering circuit Bodies & Cavities

TD Technical Data

FC33 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Priority Flow Control Valve Technical Information Series J04D3 CV Dimensions Millimeters (Inches) Check Valves SH 24.7 5 AF Hex socket (0.97) max Rotate adjuster CW to decrease priority flow or CCW to increase priority flow. Shuttle Valves LM 17 AF Hex. 12 Nm (9 lb. ft.) 24 Torque (0.94)

26 AF Hex. Load/Motor Controls 50 Nm (37 lb. ft.) Torque FC

7/8" - 14 UNF Flow Controls (3) 47.3 PC (1.86)

(2) Pressure Controls LE

(1) Logic Elements DC

Ordering Information Directional Controls J04D3 MV

Pressure Adjustment Optional Seals Body Port Compensated Style Flow Material Size

Priority Flow Setting Manual Valves Control Valve SV

Code Adjustment Style Code Seals / Kit. No. Code Body Material Code Port Size Body Part No.

Z Screw Adjust (Std.) N Nitrile, Buna-N (Std.)/ Omit Steel Omit Cartridge Only Valves W Knob Adjust (ASV014975) (SK30505N-1) A Aluminum 4P 1/4″ NPTF (B10-3-*4P) Solenoid ″ T Tamper Resistant Cap V Fluorocarbon / 6P 3/8 NPTF (B10-3-*6P) PV ″ (TC1130) (SK30505V-1) 8P 1/2 NPTF (B10-3-*8P) 6T SAE-6 (B10-3-*6T) 8T SAE-8 (B10-3-*8T) Code Optional Flow Setting 6B 3/8″ BSPG (B10-3-6B)† Proportional Valves Omit Omit for no setting* ″ 8B 1/2 BSPG (B10-3-*8B) CE Specify setting if * Add “A” for aluminum, omit for steel. required (LPM) † Steel body only. * Appropriate mid-range setting for Standard = 20 LPM Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC34 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Priority Flow Control Valve Technical Information Series J1A125 CV General Description Valves Check Priority Style, Pressure Compensated Flow Regulator Valve With Bypass. For additional information see

SH Technical Tips on pages FC1-FC4.

Shuttle Valves Features LM Free reverse flow function

Load/Motor • (3)

Controls • High flow capacity • Used for systems requiring priority flow such as steering systems FC Hardened working parts for maximum durability • (1) (3) Controls • Adjustable and tamperproof versions available (2) Flow • All external parts zinc plated

(2) PC (1) Pressure Controls

LE

Elements Specifications Performance Curve (Through cartridge only)

Logic Flow Regulating Performance Rated Flow 90 LPM (24 GPM) GPM LPM Hydraulic Oil 150 SSU @ 100°F (32 cSt) 31.7 120 DC Maximum 38 LPM (10 GPM) INLET FLOW 125 LPM (33 GPM) Directional

Controls Regulated Flow 26.4 100

Maximum Inlet 350 Bar (5000 PSI) 21.1 80 Pressure MV 15.9 60 Cartridge Material All parts steel. All operating Manual Valves parts hardened steel. 10.6 40

Regulated Flow

Operating Temp. -40°C to +93.3°C (Nitrile) 5.3 20 SV Range/Seals (-40°F to +200°F)

Solenoid -31.7°C to +121.1°C (Fluorocarbon) 0 Bypass 2 > Regulated 3 Regulated 3 > Bypass 2 Valves (-25°F to +250°F) Bar 300 200 100 100 200 300 0 PSI 4350 2900 1450 1450 2900 4350 Fluid Mineral-based or synthetic with Pressure Drop PV Compatibility/ lubricating properties at viscosities Proportional Viscosity of 45 to 2000 SSU (6 to 420 cSt) Valves Application Filtration ISO Code 16/13, SAE Class 4 or better CE Electronics Approx. Weight .45 kg (1.00 lbs.) Coils & OTHER Cavity 3A SERVICES (See BC Section for more details) BC Priority flow on steering circuit Bodies &

Cavities Form Tool Rougher Finisher

TD Technical Data

FC35 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US P.C. Priority Flow Control Valve Technical Information Series J1A125 CV Dimensions Millimeters (Inches) Check Valves

4 AF Hex socket Rotate adjuster CW SH to decrease priority 16.00 flow or CCW to (0.63) max increase priority flow. Shuttle Valves 13 AF Hex. 10 Nm (7 lb. ft.) LM Torque 24.00 (0.94) 35 AF Hex. 85 Nm (63 lb. ft.) Torque Load/Motor Controls FC 1-3/16" - 12 UNF

(3) Flow Controls 74.00 PC (2.91)

(2) Pressure Controls LE

(1) Logic Elements DC

Ordering Information Directional Controls J1A125 MV

Pressure Adjustment Optional Seals Compensated Style Regulated

Priority Flow Flow Manual Valves Control Valve Setting SV

Code Adjustment Style Code Seals / Kit. No.

Z Screw Adjust (Std.) N Nitrile, Buna-N (Std.)/ Valves W Knob Adjust (SK30011N-1) Solenoid T Tamper Resistant Cap V Fluorocarbon / PV (TC1124) (SK30011V-1)

Code Optional Regulated Proportional Valves Flow Setting Order Bodies Separately Omit Omit for no setting (Std.)* CE Specify setting if required LB10 (LPM) * Setting for standard: J1A125 Line Body Porting Body Inlet: 45 LPM (12 GPM) Material Coils & Electronics Regulated: 25 LPM (6.5 GPM) BC Code Porting 007 3/4″ BSP

066 1″ SAE

Cavities Bodies & Bodies

Code Body Material TD A Aluminum S Steel Technical Data

FC36 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Restrictive Type Pressure Compensator Valve Technical Information Series FCR101 CV General Description Valves Check Restrictive Type Pressure Compensator. This valve is designed to be used in conjunction with an external SH orifice, fixed or variable, to provide a constant flow re-

gardless of changes in load or pressure. For additional Shuttle Valves information see Technical Tips on pages FC1-FC4. Features LM Load/Motor • Hardened, precision ground parts for durability Controls • Stable and quiet response Contamination tolerant (3) • Supply • Standard valve bodies and common cavities FC • Seal variations and other options available (2)

Controls All external parts zinc plated • (2) Regulated Flow (3) Performance Curve Contol ∆∆∆P (Through cartridge only) (1) (1) PC In

Pressure IN. MM. Hydraulic Oil 150 SSU @ 100°F (32 cSt) Controls .20 5.08 2.8 Bar (40 PSI) .15 3.81 LE 5.5 Bar 11 Bar (80 PSI) Elements (160 PSI) Dimensions Millimeters (Inches) .10 2.54 Logic

46.2 21.8 Ø 15.8 (1.82) (.86)

Orifice Diameter .05 1.27 DC (.62)

Directional (2) (3)

Controls Regulated Supply 0 LPM 8 15 23 30 38 0 GPM 2 4 6 8 10 (1) Controlled Flow Inlet MV Manual Valves 1" Hex. Specifications Ø 17.4 7/8-14 UNF-2A 22 Nm (.68) Thread Rated Flow 38 LPM (10 GPM) (16 lb. ft.) Torque SV Maximum Inlet 245 Bar (3500 PSI)

Solenoid Pressure Valves Accuracy (Fixed) ±10% Spring rating to Ordering Information 210 Bar (3000 PSI) PV Adjustment Range None Proportional FCR101F Cartridge Material All parts steel. All operating Valves parts hardened steel. 10 Size Pressure Pressure SealsBody Port Compensator Valve Differential Material Size Operating Temp. -40°C to +93.3°C (Nitrile) (Fixed Style) Range/Seals (-40°F to +200°F) CE Code Press. Differential Code Body Material

Electronics -31.7°C to +121.1°C (Fluorocarbon) (-25°F to +250°F) Omit 11 Bar (160 PSI) Omit Steel Coils & Fluid Mineral-based or synthetic with 04 2.8 Bar (40 PSI) A Aluminum Compatibility/ lubricating properties at viscosities 08 5.5 Bar (80 PSI) Viscosity of 45 to 2000 SSU (6 to 420 cSt) Code Port Size Body Part No. BC Filtration ISO Code 16/13, Code Seals / Kit No. Omit Cartridge Only Bodies & Cavities SAE Class 4 or better Omit Nitrile / (SK10-3N) 4P 1/4″ NPTF (B10-3-*4P) ″ V Fluorocarbon/ 6P 3/8 NPTF (B10-3-*6P) Approx. Weight .14 kg (0.3 lbs.) ″ (SK10-3V) 8P 1/2 NPTF (B10-3-*8P) Cavity C10-3 6T SAE-6 (B10-3-*6T) TD (See BC Section for more details) 8T SAE-8 (B10-3-*8T) Technical * Add “A” for aluminum, 6B 3/8″ BSPG (B10-3-6B)† Form Tool Rougher NFT10-3R omit for steel.

Data ″ Finisher NFT10-3F † Steel body only. 8B 1/2 BSPG (B10-3-*8B)

FC37 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Restrictive Type Pressure Compensator Valve Technical Information Series FCR161 CV General Description Restrictive Type Pressure Compensator. This valve is

designed to be used in conjunction with an external Check Valves orifice, fixed or variable, to provide a constant flow re- SH gardless of changes in load or pressure. For additional information see Technical Tips on pages FC1-FC4.

Features Shuttle Valves LM • Hardened, precision ground parts for durability (3) • Stable and quiet response Supply • Contamination tolerant • Standard valve bodies and common cavities (2) Load/Motor Controls • Seal variations and other options available Regulated FC All external parts zinc plated • (2)

(3) (1)

Performance Curve In Flow Controls Contol ∆∆∆P (Through cartridge only) (1) PC IN. MM. Hydraulic Oil 150 SSU @ 100°F (32 cSt) .40 10.1 2.8 Bar (40 PSI) Pressure Controls .30 7.6 5.5 Bar 11 Bar LE (80 PSI) (160 PSI) Dimensions Millimeters (Inches) .20 5.1 73.8 13

(2.91) (.51) Logic Elements .10 2.5 Ø 26.9 Orifice Diameter (1.06) (2) (3) DC Regulated Supply 0 LPM 18.8 37.5 56.3 75.0 93.8 113 131 150 0 GPM 5 10 15 20 25 30 35 40 (1) Controlled Flow Inlet Directional Controls MV

1-5/16-12 UN-2A Specifications Ø 28.5 Thread (1.12) 1-1/2" Hex. Rated Flow 150 LPM (40 GPM) 54 Nm (40 lb. ft.) Manual Valves Torque Maximum Inlet 245 Bar (3500 PSI) SV Pressure

Accuracy (Fixed) ±10% Spring rating to Ordering Information Valves 210 Bar (3000 PSI) Solenoid Adjustment Range None FCR161F PV Cartridge Material All parts steel. All operating parts hardened steel. 16 Size Pressure Pressure SealsBody Port Compensator Valve Differential Material Size

Operating Temp. -40°C to +93.3°C (Nitrile) (Fixed Style) Proportional Valves Range/Seals (-40°F to +200°F) -31.7°C to +121.1°C (Fluorocarbon) CE (-25°F to +250°F) Code Press. Differential Code Body Material Fluid Mineral-based or synthetic with Omit 11 Bar (160 PSI) Omit Steel 04 2.8 Bar (40 PSI) A Aluminum

Compatibility/ lubricating properties at viscosities Coils & Electronics Viscosity of 45 to 2000 SSU (6 to 420 cSt) BC Filtration ISO Code 16/13, Code Seals / Kit No. Code Port Size Body Part No. SAE Class 4 or better Omit Nitrile / Omit Cartridge Only (SK16-3)

Approx. Weight .34 kg (.75 lbs.) 12T SAE-12 (B16-3-*12T) Cavities V Fluorocarbon / 16T SAE-16 (B16-3-*16T) & Bodies Cavity C16-3 (SK16-3V) * Add “A” for aluminum, omit for steel. (See BC Section for more details) TD Form Tool Rougher NFT16-3R Finisher NFT16-3F Technical Data

FC38 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Priority Type Pressure Compensator Valve Technical Information Series FCP101 CV General Description Valves Check Priority Type Pressure Compensator. This valve is designed to be used in conjunction with an external SH orifice (fixed or variable) to provide a constant flow to

the priority port. Excess flow is bypassed through Shuttle Valves port 2. For additional information see Technical Tips on pages FC1-FC4.

LM (4) Load/Motor Features Supply Controls • Hardened, precision ground parts for durability Stable and quiet response • (3) • Contamination tolerant Priority FC Standard valve bodies and common cavities • (4) (3)

Controls • All external parts zinc plated (2)

Flow Bypass Performance Curve (1) (2) Contol ∆∆∆P (Through cartridge only) PC (1) In. MM. Hydraulic Oil 150 SSU @ 100°F (32 cSt) Pressure Controls .20 5.1 5.5 Bar (80 PSI) .15 3.8 2.8 Bar 11.0 Bar LE (40 PSI) (160 PSI) Elements Dimensions Millimeters (Inches) .10 2.5 Logic

63.1 21.8 .05 1.3 Orifice Diameter Ø 19.1 (2.48) (.86) DC (.75) Ø 15.8 Directional (2) (3) (4) (.62) Controls 0 Bypass Priority Supply LPM 8 15 23 30 38 0 GPM 2 4 6 8 10 Flow (Q) (1) Inlet MV Specifications Manual Valves Ø 17.3 7/8-14 UNF-2A Rated Flow Inlet 56 LPM (15 GPM) (.68) Thread 1" Hex. Flow Setting 38 LPM (10 GPM) 22 Nm (16 lb. ft.) SV Maximum Inlet 245 Bar (3500 PSI) Torque

Solenoid Pressure Valves Accuracy (Fixed) ±10% Spring rating to Ordering Information 210 Bar (3000 PSI) PV Adjustment Range None Proportional FCP101F Cartridge Material All parts steel. All operating Valves parts hardened steel. 10 Size Pressure Pressure SealsBody Port Compensator Valve Differential Material Size Operating Temp. -40°C to +93.3°C (Nitrile) (Fixed Style) Range/Seals (-40°F to +200°F) CE Code Press. Differential Code Body Material

Electronics -31.7°C to +121.1°C (Fluorocarbon) (-25°F to +250°F) Omit 11 Bar (160 PSI) Omit Steel Coils & Fluid Mineral-based or synthetic with 04 2.8 Bar (40 PSI) A Aluminum Compatibility/ lubricating properties at viscosities 08 5.5 Bar (80 PSI) Viscosity of 45 to 2000 SSU (6 to 420 cSt) Code Port Size Body Part No. BC Filtration ISO Code 16/13, Code Seals / Kit No. Omit Cartridge Only Bodies & Cavities SAE Class 4 or better Omit Nitrile / (SK10-4N) 6P 3/8″ NPTF (B10-4-*6P) Approx. Weight .14 kg (0.3 lbs.) V Fluorocarbon / 6T SAE-6 (B10-4-*6T) (SK10-4V) 8T SAE-8 (B10-4-*8T) Cavity C10-4 6B 3/8″ BSPG (B10-4-6B)† TD (See BC Section for more details)

Technical * Add “A” for aluminum, omit for steel. Form Tool Rougher NFT10-4R † Steel body only. Data Finisher NFT10-4F

FC39 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Priority Type Pressure Compensator Valve Notes Series FCP101 CV Check Valves SH Shuttle Valves LM Load/Motor Controls FC Flow Controls PC Pressure Controls LE Logic Elements DC Directional Controls MV Manual Valves

SV

Valves Solenoid PV Proportional Valves CE Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC40 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Priority Type Pressure Compensator Valve Technical Information Series FCPH121 CV General Description Valves Check Priority Type Pressure Compensator. This valve is designed to be used in conjunction with an external SH orifice (fixed or variable) to provide a constant flow to

the priority port. Excess flow is bypassed through Shuttle Valves port 2. For additional information see Technical Tips on pages FC1-FC4.

LM

Load/Motor (4) Supply Controls Features Hardened, precision ground parts for durability • (3) FC • Stable and quiet response Priority Contamination tolerant (4) (3) Controls • (2) Bypass Flow Standard valve bodies and common cavities • (1) (2) • Steel variations and other options available PC (1) • All external parts zinc plated Inlet Pressure Controls

LE Specifications Performance Curve Elements Flow vs. Orifice Diameter Logic Rated Flow Inlet 95 LPM (25 GPM) (Through cartridge only) Flow Setting 75 LPM (20 GPM) (IN.) MM. Hydraulic Oil 150 SSU @ 100°F (32 cSt) DC .40 10.1

Directional Maximum Inlet 380 Bar (5500 PSI)

Controls Pressure

.30 7.6 Cartridge Material All parts steel. All operating parts hardened steel. MV .20 5.1 Manual

Valves Operating Temp. -40°C to +93.3°C (Nitrile) Range/Seals (-40°F to +200°F) -31.7°C to +121.1°C (Fluorocarbon) (-25°F to +250°F) Orifice Diameter SV .10 2.5

Solenoid Fluid Mineral-based or synthetic with Valves Compatibility/ lubricating properties at viscosities 0 Viscosity of 45 to 2000 SSU (6 to 420 cSt) LPM 18.9 37.9 56.8 75.8 0 GPM 5 10 15 20 PV Flow (Q) Proportional Filtration ISO Code 16/13, SAE Class 4 or better Valves

Approx. Weight .28 kg (.62 lbs.) CE

Electronics Cavity C12-4

Coils & (See BC Section for more details)

Form Tool Rougher NFT12-4R Finisher NFT12-4F BC Bodies & Cavities

TD Technical Data

FC41 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Priority Type Pressure Compensator Valve Technical Information Series FCPH121 CV Dimensions Millimeters (Inches) Check Valves SH 38.1 (1.50) Dia. Knob 36.0 39.6 38.9 (1.42) 37.7 (1.56) (1.53) (1.48) Shuttle Valves LM

1-1/4" Hex. 29 Nm

1-1/16-12 UNF-2A Load/Motor Controls (4) Thread (21 lb. ft.) Supply Torque FC 79.7 (3) (3.14) Priority Flow Controls (2) PC Bypass

(1) Ø 22.2 Pressure Controls Inlet (.87) LE

THIRD-ANGLE Screw/Knob Version Fixed Cap/Tamper Resistant Version PROJECTION Logic Elements DC

Ordering Information Directional Controls FCPH121 MV

12 Size Adjustment Pressure Seals Body Port Pressure Style Differential Material Size

Compensator Manual Valves Priority Type SV

Code Adjustment Style Code Pressure Differential Code Seals / Kit. No. Code Body Material

F Fixed style, present at Omit 11 Bar (160 PSI) Omit Nitrile / Omit Steel Valves factory (SK12-4) A Aluminum Solenoid K Knob Adjust (717784-15) V Fluorocarbon / PV (SK12-4V) S Screw Adjust Code Port Size Body Part No. T Tamper Resistant Cap (717785) Omit Cartridge Only

12T SAE-12 (B12-4-*12T) Proportional Valves * Add “A” for aluminum, omit for steel. CE Coils & Electronics

BC

Cavities Bodies & Bodies TD Technical Data

FC42 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Flow Divider/Combiner Valve Technical Information Series FDC101 CV General Description Valves Check Flow Divider/Combiner Valve. FDC101 divides flow from a single source proportionally to two actuators. In SH the reverse mode, flow from two sources is combined into one flow. When dividing or combining flow to

Divider Shuttle Valves synchronize two cylinders, please consider that the Outlet flow accuracy is ±10%. For additional information see (4) Technical Tips on pages FC1-FC4. LM Divider Load/Motor Inlet

Controls (3)

Features Divider Hardened, precision ground parts for durability Divider Outlets Outlet FC • Combiner Inlets (2) Cartridge design (2) (4)

Controls •

Flow • Ratios of 50-50, 60-40 and 66-33 available Plug • All external parts zinc plated (1) PC (3) Pressure Controls Divider Inlet Combiner Outlet

LE Specifications Performance Curve Elements Flow vs. Pressure Drop Logic Maximum Flow 45 LPM (12 GPM) (Through cartridge only) See ordering information PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt) DC 400 27.2

Directional Maximum Inlet 245 Bar (3500 PSI)

Controls Pressure

300 20.4 Accuracy ±10%

MV FDC101A44-20 Cartridge Material All parts steel. All operating 200 13.6 FDC101A66-20 Manual

Valves parts hardened steel.

FDC101A33-20 Operating Temp. -40°C to +93.3°C (Nitrile) FDC101B63-20 Range (Ambient) (-40°F to +200°F) (Pressure Drop 100 P) 6.8 SV -31.7°C to +121.1°C (Fluorocarbon) FDC101D64-20 Solenoid (-25°F to +250°F) Valves 0 LPM 8 15 23 30 38 45 Filtration ISO Code 16/13, 0 SAE Class 4 or better GPM 2 4 6 8 10 12 PV Flow (Q) Proportional

Valves Fluids Mineral-based or synthetic with lubricating properties at viscosities of 45 to 2000 SSU (6 to 420 cSt) CE

Electronics Approx. Weight .14 kg (0.3 lbs.) Coils & Cavity No. C10-4

BC Form Tool Rougher NFT10-4R Finisher NFT10-4F Bodies & Cavities Note: When machining a manifold using the FDC101, use C10-4 cavity. Do not machine a port that directs flow to the nose of the cavity. TD Technical Data

FC43 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Flow Divider/Combiner Valve Technical Information Series FDC101 CV Dimensions Millimeters (Inches) Check Valves

1" Hex. 7.9 SH 22 Nm (.31) (16 lb. ft.) Torque Shuttle Valves

7/8-14 UNF-2A LM Thread Out (Divider) (4) In (Combiner) Load/Motor Controls 63.1 FC (2.48) In (Divider) (3) Out (Combiner)

Out (Divider) (2) Flow Controls In (Combiner) PC

Ø 15.8 (.62) Pressure Controls Ø 17.3 (.68) Plug (1) LE Ø 19.1 (.75)

THIRD-ANGLE PROJECTION Logic Elements DC

Ordering Information Directional Controls FDC101 MV

10 Size Flow Seals Body Port Pressure Division Material Size**

Compensated Flow Manual Valves Control SV

Code Flow Division Code Seals / Kit. No. Code Port Size Body Part No.

A11 3.80 LPM (1 GPM) min. inlet Omit Nitrile / (SK10-4N) Omit Cartridge Only

Valves Solenoid 11.3 LPM (3 GPM) max. inlet V Fluorocarbon / (SK10-4V) 6P 3/8″ NPTF (B10-4-*6P) 50% ‘4’ Port and 50% ‘2’ Port PV 6T SAE-6 (B10-4-*6T) A33 11.3 LPM (3 GPM) min. inlet 8T SAE-8 (B10-4-*8T) 22.5 LPM (6 GPM) max. inlet Code Body Material ″ 50% ‘4’ Port and 50% ‘2’ Port 6B 3/8 BSPG (B10-4-6B)†

Omit Steel Proportional Valves A44 15.0 LPM (4 GPM) min. inlet * Add “A” for aluminum, omit for steel. † Steel body only. 30.0 LPM (8 GPM) max. inlet A Aluminum CE 50% ‘4’ Port and 50% ‘2’ Port **The FDC101 cartridge has three ports. Due to its size, it requires a B10-4 A66 22.5 LPM ( 6 GPM) min. inlet series body. As a result, all cartridges in a body will be supplied with a plug 45.0 LPM (12 GPM) max. inlet located 180° from the cartridge cavity (port 1).

50% ‘4’ Port and 50% ‘2’ Port Coils & Electronics B10-4-6T body — 6HP*50-S B64 15.0 LPM ( 4 GPM) min. inlet B10-4-8T body — 8HP*50-S BC 37.5 LPM (10 GPM) max. inlet B10-4-4P body — 102 x 4 60% ‘4’ Port and 40% ‘2’ Port B10-4-6P body — 102 x 6 B10-4-8P body — 102 x 8 D63 11.3 LPM (3 GPM) min. inlet

33.8 LPM (9 GPM) max. inlet Cavities When machining a manifold using the FDC101, use C10-4 cavity. Do not & Bodies 33% ‘4’ Port and 66% ‘2’ Port machine a port that directs flow to the nose of the cavity. TD Technical Data

FC44 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Flow Divider/Combiner Valve Technical Information Series L04A3 CV General Description Valves Check Spool Type, Flow Divider/Combiner Valve. For additional information see Technical Tips on

SH pages FC1-FC4.

Shuttle Valves (4) Features LM Interlocking spools for equal control dividing or combining

Load/Motor •

Controls Range of flow settings available for optimising control • (3) • Pressure compensated control in both directions 50/50 ratio standard, other ratios available on request Divider Outlets • Combiner Inlets FC • Commonly used for differential lock in transmission (2) (4) (2)

Controls applications Flow • Hardened working parts for maximum durability All external parts zinc plated • (1) Plug PC (3) Divider Inlet Pressure Controls Combiner Outlet

LE Specifications Performance Curve Elements Pressure Drop vs. Flow (Through cartridge only) Logic Rated Flow 60 LPM (16 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Maximum Inlet 420 Bar (6000 PSI) DC VALVES MUST NOT BE OPERATED ABOVE 28 BAR 400 PSI Directional Pressure Controls Flow Rating See Ordering Information 400 28 5-5 10-10 15-15 20-2025-25 30-30 and Ratio MV 290 20 Accuracy ± 10% Manual

Valves Per Leg 145 10

Pressure Drop (Pressure Drop P) Cartridge Material All parts steel. All operating parts hardened steel. SV 0

Solenoid LPM 10 20 30 40 50 60 0 Valves Operating Temp. -40°C to +93.3°C (Nitrile) GPM 2.6 5.3 7.9 10.6 13.2 15.9 Range/Seals (-40°F to +200°F) Flow (Q) -31.7°C to +121.1°C (Fluorocarbon) (-25°F to +250°F) PV Proportional

Valves Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2000 SSU (6 to 420 cSt) CE

Electronics Filtration ISO Code 16/13,

Coils & SAE Class 4 or better

Approx. Weight .12 kg (0.26 lbs.) BC Cavity C10-4 Bodies & Cavities (See BC Section for more details)

Form Tool Rougher NFT10-4R Finisher NFT10-4F TD Technical Data

FC45 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Flow Divider/Combiner Valve Technical Information Series L04A3 CV Dimensions Millimeters (Inches) Check Valves

8.0 SH (0.32)

26 AF Hex. 50 Nm (37 lb. ft.) Shuttle Valves Torque LM

(4) 7/8" - 14 UNF Load/Motor Controls FC 65 (2.56) (3) Flow Controls (2) PC Pressure Controls (1) LE Logic Elements DC

Ordering Information Directional Controls L04A3 MV

10 Size Flow Rating Seals Body Port Flow Divider/ and Ratio Material Size

Combiner Valve Manual Valves SV Code Total Flow Rating - Port 2 Code Seals / Kit. No. Code Port Size Body Part No. (Flow Ratio) N Nitrile, Buna-N (Std.)/ Omit Cartridge Only 5-5 6-10 LPM (1.6-2.6 GPM) (SK30506N-1) 6P 3/8″ NTPF (B10-4-*6P)

(50/50 Ratio) Valves V Fluorocarbon / 6T SAE-6 (B10-4-*6T) Solenoid 10-10 8-20 LPM (2.1-5.3 GPM) (SK30506V-1) 8T SAE-8 (B10-4-*8T) (50/50 Ratio) PV 6B 3/8″ BSPG (B10-4-6B)† 15-15 10-30 LPM (2.6-7.9 GPM) Code Body Material (50/50 Ratio) * Add “A” for aluminum, omit for steel. Omit Steel † Steel bodies only

20-20 12-40 LPM (3.2-10.6 GPM) Proportional Valves (50/50 Ratio) A Aluminum CE 25-25 13-50 LPM (3.4-13.2 GPM) (50/50 Ratio) 30-30 14-60 LPM (3.7-15.9 GPM) (50/50 Ratio) Coils & Electronics Other ratios and ratings available on request.

BC

Cavities Bodies & Bodies TD Technical Data

FC46 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Flow Divider/Combiner Valve Technical Information Series L06A3 CV General Description Valves Check Spool Type, Flow Divider/Combiner Valve. For additional information see Technical Tips on SH pages FC1-FC4.

Shuttle (4) Valves Features LM Interlocking spools for equal control dividing or combining

Load/Motor • (3) Controls • Range of flow settings available for optimising control • Pressure compensated control in both directions 50/50 ratio standard, other ratios available on request Divider Outlets • Combiner Inlets FC • Commonly used for differential lock in transmission (2) (4) (2)

Controls applications Flow • Hardened working parts for maximum durability • All external parts zinc plated PC (3) (1) Plug

Pressure Divider Inlet Controls Combiner Outlet

LE Specifications Performance Curve Elements Pressure Drop vs. Flow (Through cartridge only) Logic Rated Flow 180 LPM (47 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Maximum Inlet 420 Bar (6000 PSI) DC VALVES MUST NOT BE OPERATED ABOVE 28 BAR (400 PSI) Directional Pressure Controls Flow Rating See Ordering Information 400 28 30-30 45-45 60-60 75-75 and Ratio 90-90 MV 290 20 Accuracy ± 10% Manual

Valves Per Leg 145 10

Pressure Drop (Pressure Drop P) Cartridge Material All parts steel. All operating parts hardened steel. SV 0

Solenoid LPM 30 60 90 120 150 180 0 Valves Operating Temp. -40°C to +93.3°C (Nitrile) GPM 7.9 15.9 23.8 31.7 39.6 47.6 Range/Seals (-40°F to +200°F) Flow (Q) -31.7°C to +121.1°C (Fluorocarbon) (-25°F to +250°F) PV Proportional

Valves Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2000 SSU (6 to 420 cSt) CE

Electronics Filtration ISO Code 16/13,

Coils & SAE Class 4 or better

Approx. Weight .40 kg (0.86 lbs.) BC Cavity C16-4 Bodies & Cavities (See BC Section for more details)

Form Tool Rougher Finisher TD Technical Data

FC47 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Flow Divider/Combiner Valve Technical Information Series L06A3 CV Dimensions Millimeters (Inches) Check Valves

16.0 SH (0.63) 38 AF Hex. 100 Nm

(74 lb. ft.) Shuttle Valves Torque LM (4) 1-5/16" - 12 UNF (4) Load/Motor Controls (3) FC

102.6 (3) (4.04) (2) Flow Controls PC (2) Pressure Controls LE (1) (1) Note: Plug Port #1 in B16-4-*16T Body, use Parker #16HP5ON-S Hollow Hex Plug. Logic Elements DC

Ordering Information Directional Controls L06A3 MV

16 Size Flow Rating Seals Flow Divider/ and Ratio

Combiner Valve Manual Valves SV Code Total Flow Rating - Port 2 Code Seals / Kit. No. (Flow Ratio) N Nitrile, Buna-N (Std.)/ 30-30 20-60 LPM (5.3-15.9 GPM) (SK30510N-1)

(50/50 Ratio) Valves V Fluorocarbon / Solenoid 45-45 25-90 LPM (6.6-23.8 GPM) (SK30510V-1) (50/50 Ratio) PV 60-60 35-120 LPM (9.2-31.7 GPM) (50/50 Ratio) Order Bodies Separately

75-75 55-150 LPM (14.6-39.6 GPM) Proportional Valves (50/50 Ratio) CE 90-90 65-180 LPM (17.2-47.8 GPM) B16 4 (50/50 Ratio) 16 Size 4-Way Body Port Other ratios and ratings available on request. Cavity Material Size Coils & Electronics Code Body Material BC Omit Steel

A Aluminum

Cavities Bodies & Bodies Code Port Size Body Part No. Omit Cartridge Only TD 16T SAE-16 (B16-4-*16T) * Add “A” for aluminum, omit for steel. Technical Data

FC48 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Flow Divider/Combiner Valve Technical Information Series L1A300 CV General Description Valves Check Spool Type, Flow Divider/Combiner Valve. For additional information see Technical Tips on SH pages FC1-FC4.

(4)

Shuttle Valves Features LM Interlocking spools for equal control dividing or combining

Load/Motor •

Controls • Range of flow settings available for optimising control (3) • Pressure compensated control in both directions • 50/50 ratio standard, other ratios available on request Divider Outlets FC Commonly used for differential lock in transmission Combiner Inlets • (2) (4)

Controls applications (2) Flow • Hardened working parts for maximum durability • All external parts zinc plated PC (3) Pressure Controls Divider Inlet Combiner Outlet (1) Plug LE Specifications Performance Curve Elements Pressure Drop vs. Flow (Through cartridge only) Logic Rated Flow 320 LPM (85 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)

Maximum Inlet 350 Bar (5000 PSI) DC VALVES MUST NOT BE OPERATED ABOVE 28 BAR (400 PSI) Directional Pressure Controls 400 28 Flow Rating See Ordering Information 150 230 320 and Ratio MV 290 20 Accuracy ± 10% Manual

Valves Per Leg 145 10

Pressure Drop (Pressure Drop P) Cartridge Material Steel operating parts, hardened steel poppet. SV 0

Solenoid LPM 100 200 300 400 0 Valves Operating Temp. -40°C to +93.3°C (Nitrile) GPM 26.4 52.8 79.3 105.7 Range/Seals (-40°F to +200°F) Flow (Q) -31.7°C to +121.1°C (Fluorocarbon) (-25°F to +250°F) PV Proportional

Valves Fluid Mineral-based or synthetic with Compatibility/ lubricating properties at viscosities Viscosity of 45 to 2000 SSU (6 to 420 cSt) CE

Electronics Filtration ISO Code 16/13,

Coils & SAE Class 4 or better

Approx. Weight 1.0 kg (2.2 lbs.) BC Cavity 91-1 Bodies & Cavities (See BC Section for more details)

Form Tool Rougher Finisher TD Technical Data

FC49 Parker Hannifin Corporation Hydraulic Cartridge Systems Flow Control Valves - Order Today, SHIP TODAY at www.PartsGopher.com Catalog HY15-3502/US Flow Divider/Combiner Valve Technical Information Series L1A300 CV Dimensions Millimeters (Inches)

18.00 Check Valves (0.71) SH 46 AF Hex. 150 Nm (110 lb. ft.)

Torque Shuttle Valves

M42 x 2 LM (4) Load/Motor Controls FC (3) 155.00 (6.10) Flow Controls PC

(2) Pressure Controls LE

(1) Logic Elements DC

Ordering Information Directional Controls L1A300 MV

Flow Divider/ Flow Dividing/ Seals Combiner Valve Rating Combining

Ratio Manual Valves SV Code Flow Rating Code Seals / Kit. No. 150 60-150 LPM (15.9-39.7 GPM) N Nitrile, Buna-N (Std.)/

230 75-230 LPM (19.8-60.8 GPM) (SK30050N-1) Valves 320 110-320 LPM (29.1-84.7 GPM) V Fluorocarbon / Solenoid (SK30050V-1) PV Code Dividing/Combining Ratio 5050 50 : 50 Ratio Order Bodies Separately Other ratios available on request. Proportional Valves LB10 CE Line Body Porting Body Material

Code Porting Coils & Electronics 156 2 x 1″ BSP BC 1 x 1-1/2″ BSP 157 2 x 1″ SAE

1 x 1-1/2″ SAE

Cavities Bodies & Bodies

Code Body Material TD A Aluminum S Steel Technical Data

FC50 Parker Hannifin Corporation Hydraulic Cartridge Systems