DuPont Personal Protection 2019 Product catalog Table of contents

Overview Sizing 3 Brand cross-over intro 49 Sizing charts 6 Choosing a garment Tychem® gloves 8 Product part numbers 50 Tychem® PV350 9 Product packaging 50 Tychem® NT420 10 data 50 Tychem® NT430 12 Product line by hazard 50 Tychem® NT450 50 Tychem® NT470 ProShield® garments Original garment name 50 Tychem® NT480 ® ™ ® 15 ProShield 6 SFR DuPont Tempro 51 Tychem® NP530 16 ProShield® 10 ProShield® Basic 51 Tychem® NP560 17 ProShield® 30 DuPont™ SureStep™ 51 Tychem® NP570 CT 18 ProShield® 50 new garment 51 Tychem® BT730 ® 19 ProShield® 60 ProShield® NexGen® 51 Tychem BT770 51 Tychem® VB830 20 ProShield® 70 ProShield® 3 51 Tychem® VB870 21 ProShield® 80 new garment Cleanroom garments ® garments Original garment name 52 DuPont Controlled Environments 22 Tyvek® 400 D Tyvek® Dual 54 Tyvek® IsoClean® 23 Tyvek® 400 Tyvek® 56 ProShield® 30 26 Tyvek® 400 HV new garment 56 DuPont™ Sierra™ 27 Tyvek® 500 Tyvek® Xpert 56 Tyvek® Micro-Clean® 2-1-2 27 Tyvek® 600 Tyvek® Plus 28 Tyvek® 800 new garment 57 Tyvek® protective apparel Tychem® garments Original garment name recycling program 29 Tychem® 2000 SFR new garment 30 Tychem® 2000 Tychem® QC 32 Tychem® 4000 Tychem® SL 34 Tychem® 5000 Tychem® CPF 3 38 Tychem® 6000 Tychem® F 40 Tychem® 6000 FR Tychem® ThermoPro 42 Tychem® 9000 Tychem® BR 44 Tychem® Responder® CSM Tychem® RESPONDER® CSM 45 Tychem® 10000 Tychem® TK 47 Tychem® 10000 FR Tychem® Reflector® 48 DuPont™ Tychem® accessories

2 Customer service 1 800 931 3456 safespec..com personalprotection.dupont.com One simple system

All garment patches are in the We’ve simplified our product shape of a stop sign and each is identification system by replacing assigned a color. the original product names with an easy-to-follow numeric system. The higher the number, the greater the protection—it’s that simple. DuPont™ Tychem® For example, Tychem® QC is Orange now Tychem® 2000. Tyvek® is now Tyvek® 400.

DuPont™ Tyvek® Blue

™ ® DuPont ProShield We’ve updated our SafeSPEC™ Gray selector tool to reflect the new product identification system. Visit safespec.dupont.com to search by industry or hazard to help you select a garment.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 3 Original New

® ® ® Heavy chemical exposure Reflector® Tychem Reflector Tychem 10000 FR

Tychem ® TK Tychem ® 10000 Tychem ® RESPONDER® ® ® ® Responder CSM Tychem Responder CSM CSM Tychem ® BR Tychem ® 9000

® ® ThermoPro Tychem ThermoPro Tychem 6000 FR

Tychem ® F Tychem ® 6000

Tychem ® CPF 3 Tychem ® 5000

Tychem ® SL Tychem ® 4000

Tychem ® QC Tychem ® 2000

new garment Tychem ® 2000 SFR

new garment Tyvek ® 800

Tyvek ® Plus Tyvek ® 600

Tyvek ® Xpert Tyvek ® 500 of protection Level Light chemical exposure

new garment Tyvek ® 400 HV Non-hazardous particles Tyvek ® Tyvek ® 400 Hazardous particles Non-hazardous light liquid Tyvek ® Dual Tyvek ® 400 D splash and aerosols

new garment ProShield® 80

ProShield® 3 ProShield® 70 Non-hazardous particles, ® ® ProShield NexGen ProShield® 60 liquids and aerosols

new garment ProShield® 50

DuPont™ SureStep™ ProShield® 30

ProShield® Basic ProShield® 10 Non-hazardous particles Non-hazardous particles DuPont™ Tempro® ProShield® 6 SFR and aerosols Flame resistance D = Dual FR = Flame-resistant SFR = Secondary flame-resistant

4 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com Tychem® 10000 FR

Tychem® 10000

® ® Tychem Tychem ® Responder 9000 CSM

Tychem® 6000 FR

® ® Tychem Tychem 6000 5000

Tychem® 4000

Tychem® 2000 Tyvek® ® ® 800 Tychem Tyvek 2000 SFR of protection Level 400 HV Tyvek®

® 600 ® Tyvek ProShield 400 80 Tyvek®

® ® 500 ProShield ® Tyvek ProShield 10 400 D 70 ProShield® ® 6 SFR ProShield 60

ProShield® 50

ProShield® 30

Non-hazardous Non-hazardous Light chemical Heavy chemical particles and particles, liquids exposure exposure aerosols and aerosols Flame resistance

Non-hazardous Non-hazardous particles particles Hazardous particles Non-hazardous light liquid splash and aerosols

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 5 Choosing a garment

Before searching for an appropriate chemical protective garment, you should assess the nature of the hazard and the working environment. Different factors including concentration, temperature and pressure must be matched to the garment’s fabric, design and seam construction.

Fabric Fabric technologies typically used No matter what the brand or trade name, almost all in protective garments limited-use protective apparel products can be classified All images are magnified. into one of a few general fabric technologies. It is important to understand the attributes of the fabric being used for a given application. Why? Not all fabrics Exclusive DuPont technologies used in chemical protective garments are the same. From exclusive DuPont technologies such as Tychem® and Tyvek® to spunbond-meltblown-spunbond (SMS) and microporous Tychem® film fabrics, DuPont offers a variety of fabrics with different Chemical barrier fabrics specifically levels of comfort, durability, breathability and protection to engineered for protection over a range of hazards. meet your specific needs. In order to select the appropriate protective garment, it is crucial to know how well the fabric used in the garment provides a barrier to specific hazardous materials. Tyvek® Tyvek® is 100% high-density Testing for chemical protective fabrics can be divided into entangled into a protective material— two primary categories: with no fillers or thin films to wear away. Made only by DuPont, it offers superior 1) penetration testing—appropriate for particle hazards protection and durability. 2) permeation testing—appropriate for liquid and gaseous hazards

Penetration occurs when there is bulk movement of a Microporous films (MPF) material through a pore, hole, gap or defect in the fabric Bi-laminate with a thin microporous film layer on a spunbonded and is the proper method to evaluate particle barrier. nonwoven, these fabrics offer limited Permeation, on the other hand, occurs when there is durability—barrier protection is lost when movement of the material through the barrier fabric on the film layer is abraded. performance fabric Increased a molecular level. It is possible for a liquid or vapor to permeate through a fabric even when there is no observed opening in the fabric. Permeation testing is a more sensitive Spunbond-meltblown-spunbond (SMS) SMS fabrics rely on the meltblown and representative way of characterizing the interaction of polypropylene layer in the middle of the liquids and gases with the barrier fabric. Permeation testing open tri-laminate polypropylene structure is critical for fabrics that are exposed to hazardous liquids, to act as the main filter for particles. vapors or gases. Spunbond polypropylene (SBPP) With their highly open structure, SBPP fabrics offer negligible barrier protection.

6 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com Choosing a garment

Seam construction The high-visibility colors chosen for Tychem® fabrics were based on extensive research. For example, the human eye is Seams are a critical component of the overall barrier more sensitive to the lime yellow of DuPont™ Tychem® 10000 protection provided by a chemical protective garment. It is and the safety yellow color of Tychem® 9000 and Tychem® vital to select the appropriate seam configuration for your 2000 fabrics. On the other hand, there are instances when application needs and to know that the garment will be being visible is dangerous. When discretion is preferred—or constructed with strong, tight seams. One loose or required—special low-visibility fabrics, such as Tychem® gap and the barrier between you and your environment 2000 SFR and Tychem® 5000, are harder to see and blend unravels—leaving you vulnerable. into a variety of environments. Garment style DuPont offers a wide variety of garment styles—from hoods and shoe covers to aprons, coveralls and fully encapsulated suits. S B Fully encapsulated suits are available with front or rear entry, with a flat back for airline accommodation or an Serged or sewn* Bound* expanded back for SCBA accommodation. A seam produced when three Tightly sewn with a reinforced threads are interlocked around outer binding to increase Hoods the raw edges of two pieces of seam strength and barrier. material for a strong, stress- For potential misting exposure resistant seam. of non-hazardous liquids or particle penetration through the seam.

Standard Respirator fit Elastomeric faceseal

T T In addition to our standard hood design, many of our garments offer a respirator fit hood. These hoods are designed Taped Double taped with a longer zipper for complete coverage of the neck area. Both sewn and taped to provide Sewn, then taped on the inside strong chemical resistance and the outside of the seam Faceshields against heavy liquid splashes and for a very strong chemical- tough seam stress. and stress-resistant seam. A sewn seam is covered with a strip of compatible material by heat-sealing.

*Serged and/or bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present.

Standard EX (extra-wide) In addition to the standard faceshield, DuPont has several garment styles that offer a greater field of vision, enabling the wearer to see more of what they are dealing with, reducing missteps and allowing more natural movement and better eye contact. High visibility Low visibility The EX (extra-wide) faceshield options on Tychem® 10000 High visibility can be either a help or a hindrance for and Tychem® 9000 Level A garments feature a wrap-around emergency responders. For example, in hazardous design that provides ample room for a mask-mounted situations, it is critical that emergency responders can be regulator. This faceshield is wider and longer, providing easily seen. In addition, hazardous material emergencies expanded peripheral and vertical viewing. often occur in poorly lit environments—thus the need for high visibility.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 7 Product part numbers

To simplify ordering and inventory management, we developed a simple, logical and intuitive product part numbering system. Using only 16 characters, each part number comprises abbreviations that provide all the information you need.

Base catalog number Additional product detail The first six characters provide the basic The remaining characters provide additional product representation of the product. detail and complete the full part number.

TY 120 S WH LG 0025 00

Fabric Style Seam Color Size count Options The first two construction Many DuPont The number characters are the garments are of garments Abbreviations fabric description. Abbreviations available in a range per case. such as S Serged or of sizes; refer to TV  Trade Agreement Abbreviations sewn catalog descriptions Act compliant for details. Tychem® B Bound VP Vend packed RF 10000 FR T Taped or Abbreviations* Not all option codes double taped are available for all 10000 SM Small TK products; refer to See page 7 for RC  Responder® CSM MD Medium catalog descriptions details. for details. BR 9000 LG Large See next page for TP 6000 FR XL Extra large abbreviations. TF 6000 2X 2 Extra large TYF 6000 DuPont offers a wide array 3X 3 Extra large of garment styles— C3 5000 4X 4 Extra large from hoods, aprons SL 4000 and coveralls to fully 5X 5 Extra large encapsulated suits. QC 2000 6X 6 Extra large Each garment style has a QS 2000 SFR 7X 7 Extra large unique three-digit code. 99 Accessories 00 Universal Tyvek® See page 49 for sizing charts. TJ 800 TY 600 Several DuPont fabrics are available TY 500 in color options. TY 400 HV Abbreviations TY 400 BU Blue TD 400 D *Not all sizes are available in all styles. GR Green Stock items versus make to order

FC 400 FC ® ® GY Gray For ProShield and Tyvek garments, sizes medium to 4X are ProShield® Gloves identified as stock items. Sizes small and 5X and above are LY Lime yellow identified as make to order. Certain accessory items are also P8 80 VB Viton™ butyl identified as make to order. OR Orange Most garments in the Chemical/Hazmat line (Tychem® 2000, P3 70 BT Butyl ® ® ® ® ® Silver Tychem 4000, Tychem 6000, Tychem 9000, Tychem Responder SV ® NG 60 NP CSM and Tychem 10000) are identified as make to order. A small TN Tan grouping is identified as stock items, following the same size NB 50 NT Nitrile guidelines as indicated above. WH White Stock/make to order designations are based on sales volume and PB 10 PV PVC YL Yellow production efficiencies. Therefore, designations are subject to TM 6 SFR change without notice.

8 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com Product part numbers Product packaging

Option code abbreviations Vend packed 00 Standard offering Some garments are available for use in vending machines. 0B Bulk pack These garments feature option code “VP”. 2K Double storm flap w/zipper & hook-and-loop closure 5C Viton™ butyl 5V Viton™ butyl 7C MSA connector pass-thru CAMDS (#491335) right side 7M MSA dual purpose w/Foster fitting 990060 7N MSA quick fill w/Schrader fitting 990190 7R MSA dual purpose #495670 Hansen fitting (left front waist) 7S Scott® pass-thru #803620-01 Hansen fitting (right side) 7W Interspiro pass-thru #33689006 BN Berry Amendment compliant G1 Reduced case quantity HL Hook-and-loop JF CPE sleeve cuff and jam fit insert LG 8.25˝ high shoe cover New packaging NF NAFTA sourced Our new packaging is labeled with the same stop sign NP Respirator fit hood and storm flap shapes as the garments. NS Non-skid material PI Packaged individually RF Respirator fit hood SR Skid-resistant TV Trade Agreement Act compliant VP Vend packed WG With gloves

Option codes for Tyvek® IsoClean® garments*: CS Clean and sterile: clean-processed, individually packaged and sterilized by gamma radiation 0S Sterile: individually packaged and sterilized by gamma radiation 0C Clean: clean-processed, individually packaged 00 or 0B Bulk packaged PI Individually packaged in an opaque

*See pages 54-55 for Tyvek® IsoClean® garments.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 9 Permeation data Mid level

21 Industrial chemicals CAS # Physical Tychem® Tychem® Tychem® Tychem® Tychem® Tychem® ASTM F1001 phase 2000 SFR 2000* 4000* 5000 6000 6000 FR Original garment name New garment QC SL CPF 3 F ThermoPro

Acetone (95%) 67-64-1 L nt imm. imm. >480 >480 >480 Acetonitrile (95%) 75-05-8 L nt imm. 60 imm. 131 >480 Ammonia (95%) 7664-41-7 G nt imm. 26 imm. 20 90 1, 3-Butadiene (95%) 106-99-0 G nt imm. >480 >480 >480 >480 Carbon disulfide (95%) 75-15-0 L nt imm. imm. 16 >480 >480 Chlorine (95%) 7782-50-5 G nt imm. >480 imm. >480 >480 Dichloromethane (95%) 75-09-2 L nt imm. imm. imm. imm. imm. Diethylamine (95%) 109-89-7 L nt imm. 15 >480 >480 >480 N, N-Dimethylformamide (95%) 68-12-2 L nt imm. 90 >480 >480 >480 Ethyl acetate (95%) 141-78-6 L nt imm. imm. >480 >480 >480 Ethylene oxide (95%) 75-21-8 G nt imm. imm. >480 126 >480 n-Hexane (95%) 110-54-3 L nt imm. imm. >480 >480 >480 Hydrogen chloride (95%) 7647-01-0 G nt imm. >480 >480 >480 >480 Methanol (95%) 67-56-1 L nt imm. >480 imm. 117 >480 Methyl chloride (95%) 74-87-3 G nt imm. >480 >480 >480 >480 Nitrobenzene (95%) 98-95-3 L nt imm. 59 >480 >480 >480 Sodium hydroxide (50%) 1310-73-2 L >480 >480 >480 >480 >480 >480 Sulfuric acid (95%) 7664-93-9 L >480 >480 >480 >480 >480 50

1, 1, 2, 2-Tetrachloroethylene (95%) 127-18-4 L nt imm. imm. >480 >480 >480

Tetrahydrofuran (95%) 109-99-9 L nt imm. imm. >480 >480 >480 Toluene (95%) 108-88-3 L nt imm. imm. >480 >480 >480

Chemical warfare agents**

Lewisite (L) 541-25-3 L nt nt >3601 1201 3602 3602

Mustard (HD) 505-60-2 L nt nt >4801 1201 >4802 >4802

Tabun (GA) 77-81-6 L nt nt nt nt >4804 >4804

Sarin (GB) 107-44-8 L nt nt >4803 1203 >4804 >4804

Soman (GD) 99-64-0 L nt nt nt >4803 >4804 >4804 VX Nerve Agent 50782-69-9 L nt nt >4803 >4803 >4804 >4804 Index of codes: > = greater than, imm. = immediate (<10 minutes), nt = not tested, L = liquid, G = gas

Normalized Breakthrough Time (NBT) shown in minutes. The product information contained is current as of the ** Chemical warfare agents are tested according to the *Serged and/or bound seams are degraded by some date of publication, but may be revised as new information following protocols. All chemicals have been tested at hazardous liquid chemicals, such as strong acids, and is developed. Before relying on any performance data a concentration of greater than 95% unless otherwise should not be worn when these chemicals are present. for the purchase or performance of products, you should stated. All tests are performed at 22°C and 50% R.H. check safespec.dupont.com or contact DPP Customer Actual Breakthrough Times, in minutes, are reported: Actual Breakthrough Time in minutes. Service at 1 800 931 3456 to determine whether there 1 Protocol DN3-MIL-STD-282, Method T-209 (HD) or Permeation testing on chemicals is in accordance with is new information that relates to your intended use or modified for Lewisite, for 8 hours at 10 g/m2. ASTM F739, Standard Test Method for Resistance of application of the product. 2 Protective Clothing Materials to Permeation by Liquids or Protocol DN4-MIL-STD-282, Method T-209 (HD) or Note: Numbers reported are averages of samples tested. modified for Lewisite, for 8 hours at 100 g/m2 Gases Under Conditions of Continuous Contact. All tests Sample results vary. are conducted at room temperature unless otherwise (total coverage). noted. Reported results are Normalized Breakthrough All DuPont permeation testing is performed by a 3 Protocol DN5-MIL-STD-282, Method T-208 (GB) or Times defined by ASTM F739 as the time (in minutes) third party. modified for GA, GD and VX, for 8 hours at 10 g/m2. 2 when the permeation rate reaches 0.1 µg/cm /min. 4 Protocol DN6-MIL-STD-282, Method T-208 (GB) or modified for GA, GD and VX, for 8 hours at 100 g/m2 (total coverage).

10 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com Permeation data High level

21 Industrial chemicals CAS # Physical Tychem® Tychem® Tychem® Tychem® ASTM F1001 phase 9000 Responder® CSM 10000 10000 FR Original garment name BR RESPONDER® CSM TK Reflector®

Acetone 67-64-1 L >480 >480 >480 >480 Acetonitrile 75-05-8 L >480 >480 >480 >480 Ammonia 7664-41-7 G 133 >480 >480 >480 1, 3-Butadiene 106-99-0 G >480 >480 >480 >480 Carbon disulfide 75-15-0 L >480 >480 >480 >480 Chlorine 7782-50-5 G >480 >480 >480 >480 Dichloromethane 75-09-2 L >480 >480 >480 >480 Diethylamine 109-89-7 L >480 >480 >480 >480 N, N-Dimethylformamide 68-12-2 L >480 >480 >480 >480 Ethyl acetate 141-78-6 L >480 >480 >480 >480 Ethylene oxide 75-21-8 G >480 >480 >480 >480 n-Hexane 110-54-3 L >480 >480 >480 >480 Hydrogen chloride 7647-01-0 G >480 >480 >480 >480 Methanol 67-56-1 L 185 >480 >480 >480 Methyl chloride 74-87-3 G >480 >480 >480 >480 Nitrobenzene 98-95-3 L >480 >480 >480 >480 Sodium hydroxide, 50% 1310-73-2 L >480 >480 >480 >480 Sulfuric acid 7664-93-9 L >480 >480 >480 >480 1, 1, 2, 2-Tetrachloroethylene 127-18-4 L >480 >480 >480 >480 Tetrahydrofuran 109-99-9 L >480 >480 >480 >480 Toluene 108-88-3 L >480 >480 >480 >480

Chemical warfare agents**

Lewisite (L) 541-25-3 L >4801 >480t >4802 >4801

Mustard (HD) 505-60-2 L >4802 >4802 >4802 >4802

Tabun (GA) 77-81-6 L >4803 >4803 >4804 >4803

Sarin (GB) 107-44-8 L >4804 >4804 >4804 >4804

Soman (GD) 99-64-0 L >4803 >4803 >4804 >4803 VX Nerve Agent 50782-69-9 L >4804 >4804 >4804 >4804 Index of codes: > = greater than, imm. = immediate (<10 minutes), nt = not tested, L = liquid, G = gas

Normalized Breakthrough Time (NBT) shown in minutes. The product information contained is current as of the ** Chemical warfare agents are tested according to the *Serged and/or bound seams are degraded by some date of publication, but may be revised as new information following protocols. All tests are performed at 22˚C hazardous liquid chemicals, such as strong acids, and is developed. Before relying on any performance data and 50% R.H. Actual Breakthrough Times, in minutes, should not be worn when these chemicals are present. for the purchase or performance of products, you should are reported: check safespec.dupont.com or contact DPP Customer 1  Actual Breakthrough Time in minutes. Protocol DN3-MIL-STD-282, Method T-209 (HD) or Service at 1 800 931 3456 to determine whether there modified for Lewisite, for 8 hours at 10 g/m². Permeation testing on chemicals is in accordance with is new information that relates to your intended use or 2  ASTM F739, Standard Test Method for Resistance of application of the product. Protocol DN4-MIL-STD-282, Method T-209 (HD) or Protective Clothing Materials to Permeation by Liquids or modified for Lewisite, for 8 hours at 100 g/m² Note: Numbers reported are averages of samples tested. (total coverage). Gases Under Conditions of Continuous Contact. All tests Sample results vary. are conducted at room temperature unless otherwise 3 Protocol DN5-MIL-STD-282, Method T-208 (GB) or noted. Reported results are Normalized Breakthrough All DuPont permeation testing is performed by a modified for GA, GD and VX, for 8 hours at 10 g/m². third party. Times defined by ASTM F739 as the time (in minutes) 4 Protocol DN6-MIL-STD-282, Method T-208 (GB) or 2 when the permeation rate reaches 0.1 µg/cm /min. modified for GA, GD and VX, for 8 hours at 100 g/m² (total coverage).

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 11 Product line by hazard

When it comes to addressing a broad range of hazards in easy-to-use interactive tool that provides suggestions the workplace, specifiers have many product options from for chemical protective clothing based on the user’s which to select. The process to understand which option hazard scenario. matches a given situation can be confusing and taxing. Our database includes the permeation data of hundreds DuPont Personal Protection has tried to reduce some of of chemicals, including warfare agents and the ASTM that burden by providing a complete line of products with F1001 standard list of challenge chemicals. This tool can supporting information to help guide specifiers through the be accessed on our website at safespec.dupont.com. To selection process. provide a quicker overview of our products and where they To get the most out of your personal protective equipment are ideally suited for use, we developed the simple guide (PPE), it is necessary to understand where the products are below. Our goal was to match the level of protection and intended to be used. DuPont™ SafeSPEC™ is a sophisticated, value for a given exposure hazard.

Tyvek® and ProShield® products

Typical general industrial hazards/description/examples Non-hazardous Hazardous

Bloodborne Flame** Particles Aerosol Light liquid splash* Particles Aerosol pathogens resistance

General Animal Sanding & Spray Oil & Lubri- Fertilizer Sewage Fertilizer Pesti- Lead Chro- Berylium Mold - Carbon Radio- Isocyanate dirt waste grinding paint grease cants cides mium active containing & grime waste particles Garment

Tyvek® 400 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Tyvek® 400 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● HV

Tyvek® 500 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Tyvek® 600 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Tyvek® 800 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

ProShield® 80 ●

ProShield® 70 ●

ProShield® 60 ● ● ● ● ● ● ● ● ●

ProShield® 50 ● ● ● ● ● ● ● ●

ProShield® 10 ● ● ● ● ● ● ● ●

® ProShield 6 ● ● ● ● ● ● ● SFR

● Generally preferred ● Acceptable for use

*Liquid barrier performance varies based on the amount of liquid that may get on It is the user’s responsibility to determine the nature and level of hazard and the the garment, the length of time the liquid is on the garment, applied pressure and proper personal protective equipment (PPE) needed. The information set forth certain physical properties of the liquid. Tyvek® and ProShield® garments are not herein reflects laboratory performance of fabrics, not complete garments, under appropriate if during use they are getting wet (liquid is dripping or running, or it controlled conditions. It is intended for information use by persons having technical is wet to the touch) or if spotting is observed on skin or garments worn under the skill for evaluation under their specific end-use conditions, at their own discretion protective garment. Serged and bound seams are degraded by some hazardous and risk. Anyone intending to use this information should first verify that the liquid chemicals, such as strong acids, and should not be worn when these garment selected is suitable for the intended use. In many cases, seams and closures chemicals are present. Tyvek® 600 and Tyvek® 500 garments use a special type have shorter breakthrough times and higher penetration rates than the fabric. of Tyvek® fabric, which has different physical properties and improved chemical Please contact DuPont for specific data. If the garment becomes torn, abraded or resistance properties when compared to fabric used in standard Tyvek® garments. punctured, end user should discontinue use of garment to avoid potential exposure. ® Additionally, the seams used in standard Tyvek garments are different than the Latex statement: As of January 1, 2006, DuPont production specifications exclude ® ® ® seams for Tyvek 600 and Tyvek 500 garments. Tyvek 600 garments offer seams use of components containing latex in the manufacture of Tyvek® ® that are sewn and then taped, and Tyvek 500 garments offer external sewn seams, IsoClean®, Sierra™ and ProClean® garments. where the seam thread is visible on the outside of the garment. Tyvek® 500 and ® ® ® Tyvek® 600 garments offer improved liquid barrier, but may not be appropriate if Tyvek 500, Tyvek 600 and Tyvek 800 contain natural rubber latex, which may spotting is observed on the skin or garments worn under the protective garment. cause allergic reactions in some sensitized individuals. Anyone who begins to In applications where a higher liquid barrier is needed, consider Tychem® 2000 and exhibit an allergic response during the use of DuPont products should immediately Tychem® 4000 garments with taped seams. cease using these products. The incident should also be reported to DuPont at 1 800 441 3637 so that an investigation can be initiated. **ProShield ® 6 SFR garments offer secondary flame resistance and are to be worn over primary flame-resistant garments such as ® IIIA.

12 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com Product line by hazard

Tychem® chemical protection products

Typical chemical hazards/examples Hazardous Bloodborne Light Moderate Potential Heavy ChemBio Chemical dry pathogens chemical liquid flash liquid & vapors powders & biohazards splash & chemical exposure chemical warfare & gases NFPA & solids aerosols splash & liquid splash agents (toxics & Ensembles organic (toxics & corrosives) chemicals corrosives)

Dry pharma Blood, Inorganic Organics, Meth- Known Sarin, Chlorine, 1991 1991 1992 1994 2112 70E chemicals saliva, acids and solvents amphetamine carcinogens mustard, anhydrous Flash Liquid Class Cat human bases, VX nerve agent ammonia fire gas 2 2 Garment excrement salts option option

® Tychem ● ● ● 2000 SFR

Tychem® 2000 ● ● ●*

Tychem® 4000 ● ● ●* ●

Tychem® 5000 ● ● ● ● ● ●

Tychem® 6000 ● ● ● ● ● ●

Tychem® 6000 FR ● ● ● ● ● ● ● ● ●

Tychem® 9000 ● ● ● ● ● ● ●

Tychem® Responder® ● ● ● ● ● ● ● CSM

Tychem® 10000 ● ● ● ● ● ● ● ●

Tychem® 10000 FR ● ● ● ● ● ● ● ● ● ●

● Generally preferred ● Acceptable for use

*Serged and/or bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 13 Product line by hazard

Tychem® gloves

Gloves Typical industrial general hazards PV350 NT420 NT430 NT450 NT470 NT480 NP530 NP560 NP570CT BT730 BT770 VB830 VB870

Bloodborne pathogens Pass Pass Pass Pass (ISO 16604 Class 6)

Food handling Pass Pass Pass Pass Pass Pass (FDA 21 CFR 177.2600)

Cut resistance Pass (ANSI level A5, EN level 5)

Dry powders ● ● ● ● ● ● ● ● ● ● ● ● ●

Hydrogen peroxide (30%) ● ● ● ● ● ● ● ● ● ●

Liquid inorganic acids ● ● ● ● ● ● ● ● ● ● ●

Liquid inorganic bases ● ● ● ● ● ● ● ● ● ● ● ● ●

Alcohols ● ● ● ● ● ● ● ● ●

Hydrocarbons ● ● ● ● ● ● ● (non-aromatic)

Aromatic hydrocarbons ● ●

Isocyanates ● ●

Ketones ● ● ● ●

Amines ●

Hazardous gases ● ● ● ● (such as Cl2, NH3, HF, HCl)

Comparison within the DuPont portfolio: ● Generally preferred ● Acceptable for use (Blank) Not recommended

It is the user’s responsibility to determine the nature and level of hazard and the proper Tychem® gloves are designed for limited use. They can be worn until damaged, altered or personal protective equipment (PPE) needed. The information set forth herein reflects contaminated. If the gloves have not been contaminated, they can be cleaned for hygienic laboratory performance of materials under controlled conditions. It is intended for information purposes and reused. use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. Anyone intending to use this information should first verify that Potential allergens: the glove selected is suitable for the chemical(s) being handled and the intended use. Please Thiazoles–NT420, NT450 contact DuPont for specific data. There may be several Tychem® gloves that can provide the Carbamate–NT470, NT480, NP530 necessary protection against a specific chemical. Sometimes the work scenario may have other Natural rubber latex–NP530 factors, such as the need for increased dexterity or cut protection, that should be taken into account based on the Tychem® glove options available which offer the necessary chemical Anyone who begins to exhibit an allergic response during the use of DuPont products protection level. should immediately cease using these products. The incident should also be reported to DuPont at 1 800 441 3637 so that an investigation can be initiated.

14 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ ProShield® 6 SFR Original name: DuPont™ Tempro®

Coverall1 Secondary flame-resistant (SFR)

TM120SBUXX002500 Lightweight, disposable overgarment MD–6X designed to help protect and preserve TM120SBUXX0025PI primary flame-resistant garments MD–4X Provides a barrier against Serged seams non-hazardous particles and Collar aerosols while not contributing Zipper closure to burn injury

Won’t ignite and continue to burn when exposed to a flame source

ProShield® 6 SFR is blue Coverall1

TM122SBUXX002500 MD–7X TM122SBUXX0025PI MD–4X

Serged seams Attached hood Zipper closure Elastic wrists Elastic ankles Attached boot covers2

TM127S Coverall1

TM127SBUXX002500 MD–6X TM127SBUXX0025PI MD–4X

Serged seams Attached hood Zipper closure Elastic wrists Elastic ankles

ProShield® 6 SFR garments are treated, 2These ProShield® 6 SFR garments have attached boot not inherently flame-resistant, and are intended to be covers made of the garment material. These attached worn over your primary flame-resistant garments. boot covers must be worn inside protective outer Serged and/or bound seams are degraded by some footwear and are not suitable as outer footwear. These attached boot covers do not have adequate durability or hazardous liquid chemicals, such as strong acids, and ProShield® 6 SFR should not be worn when these chemicals are present. slip resistance to be worn as the outer foot covering. of protection Level 1Styles do not have storm flaps. Note: Not all sizes available in all styles.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 15 DuPont™ ProShield® 10 Original name: ProShield® Basic

Coverall Lab coat

PB120SWHXX002500 PB212SBUXX003000

PB120SBUXX002500 Serged seams Collar Serged seams Snap closure Collar Two pockets Zipper closure SM–7X Storm flap MD–7X

Coverall Lab coat

PB122SWHXX002500 PB219SWHXX003000 PB122SBUXX002500 PB219SBUXX003000

Serged seams Serged seams Attached hood Knit collar Zipper closure Set sleeve Storm flap Knit cuff Elastic wrists Snap closure Elastic ankles (6 + 1 adjustable) Attached skid-resistant Pockets boot covers (1 left chest pencil, 2 lower front) PB127S MD–7X SM–4X Comfort and quality at an affordable price Coverall Frock Spunbond-meltblown-spunbond PB125SWHXX002500 PB267SWHXX003000 (SMS) garments

PB125SBUXX002500 Serged seams Uses include general maintenance, Mandarin collar janitorial/cleaning and other dirty Serged seams Set sleeve work assignments Collar Knit cuff Zipper closure ® Elastic wrists ProShield 10 is available in blue or Storm flap Snap closure white, and gray in style 127 Elastic wrists (6 + 1 adjustable) Elastic ankles SM–4X MD–7X

Coverall Frock

PB127SWHXX002500 PB271SWHXX003000 PB127SBUXX002500 PB271SBUXX003000

PB127SGYXX002500 Serged seams Mandarin collar Serged seams Zipper closure Attached hood Elastic wrists Zipper closure MD–4X Storm flap Elastic wrists Elastic ankles ProShield® 10 MD–7X Level of protection Level

16 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ ProShield® 30 Original name: DuPont™ SureStep™

Boot cover Shoe cover

PE444SWHXX010000 PE440SWHXX020000

Serged seams Serged seams Elastic openings Elastic openings Elastic ankles 5.5" height 13" height 200/cs 100/cs MD–XL LG–XL

Spunbonded polypropylene with Shoe cover polyethylene film

PE440SBUXX020000 Slip resistance—both wet and dry Serged seams Elastic openings 5.5" height 200/cs LG–XL Level of protection Level ProShield® 30

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 17 DuPont™ ProShield® 50 Original name: new garment

Coverall Coverall

NB120SWHXX002500 NB122SWHXX002500

Serged seams Serged seams Collar Attached hood Zipper closure Zipper closure SM–6X Elastic wrists Elastic ankles Attached skid-resistant boot covers SM–6X

Coverall Apron

NB125SWHXX002500 NB273BWHXX010000

Serged seams Bound seams Collar Bound neck and ties Zipper closure Bib style Elastic wrists 28˝ x 36˝ Elastic ankles One size fits most SM–6X

Coverall Sleeves NB127S NB127SWHXX002500 NB500SWHXX0200YU Provides a barrier against a range of Serged seams Serged seams non-hazardous aerosols, light liquid Attached hood (respirator fit)2 Elastic openings splash and dry particles Zipper closure 24˝ length Storm flap One size fits most Microporous film laminated to a Elastic wrists Elastic ankles SM–6X Industries and applications include janitorial, sanitation, general industrial maintenance

Lighter weight and roomy design make for greater comfort and mobility

ProShield® 50 is white

2Respirator fit hoods are designed with a longer zipper, Note: Not all sizes available in all styles. extending to the chin for complete coverage of the neck Warning: ProShield® 50 should not be used around heat, area. Standard hoods only extend to the neck. flames, sparks or in potentially flammable or explosive See page 7 for photos. environments. Garments made of ProShield® 50 fabric Bound and sewn seams and closures have less barrier should have slip-resistant or anti-slip materials on the than fabric. outer surface of boots, shoe ­covers, or other garment Serged and/or bound seams are degraded by some surfaces in conditions where slipping could occur. ProShield® 50 of protection Level hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present.

18 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ ProShield® 60 Original name: ProShield® NexGen®

Coverall Apron

NG120SWHXX002500 NG273BWHXX010000

Serged seams Bound seams Collar Bound neck and ties Zipper closure Bib style SM–6X 28˝ x 36˝ One size fits most

Coverall Lab coat

NG125SWHXX002500 NG212SWHXX003000

Serged seams Serged seams Collar Collar Zipper closure Snap closure Elastic wrists Two pockets NG127S Elastic ankles SM–4X SM–5X Barrier against a variety of non-hazardous aerosols, liquids and dry particles

Microporous film laminated to a Coverall Sleeves nonwoven fabric NG127SWHXX0025NP NG500SWHXX020000 Uses include automotive refinishing, Serged seams Serged seams waste cleanup and sanitation Attached hood (respirator fit)2 Elastic openings engineering Zipper closure 18˝ length ® Storm flap One size fits most ProShield 60 is white Elastic wrists Elastic ankles SM–7X 2Respirator fit hoods are designed with a longer zipper, extending to the chin for complete coverage of the neck area. Standard hoods only extend to the neck. Coverall Shoe cover See page 7 for photos. Bound and sewn seams and closures have less barrier NG122SWHXX002500 NG451SWHXX020000 than fabric. Serged and/or bound seams are degraded by some Serged seams Serged seams hazardous liquid chemicals, such as strong acids, and Attached hood Elastic openings should not be worn when these chemicals are present. Zipper closure 5˝ height Note: Not all sizes available in all styles. ® Elastic wrists ProShield 60 fabric shaft Warning: ProShield® 60 should not be used around heat, Elastic ankles PVC sole flames, sparks or in potentially flammable or explosive Attached skid-resistant boots 200/cs (100 pairs) environments. Garments made of ProShield® 60 fabric should have slip-resistant or anti-slip materials on the SM–6X SM–XL outer surface of boots, shoe ­covers, or other garment surfaces in conditions where slipping could occur. Boot cover

NG456SWHXX010000

Serged seams Elastic openings Elastic ankles 18˝ height ProShield® 60 fabric shaft PVC sole ProShield® 60 100/cs (50 pairs) of protection Level SM–XL

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 19 DuPont™ ProShield® 70 Original name: DuPont™ ProShield® 3

Shoe cover Skid-resistant material for shoe/boot covers to help prevent slipping P3450SGYXX020000 Provides non-hazardous liquid Serged seams splash protection Elastic openings 5˝ height ProShield® 70 is gray ProShield® 70 fabric Skid resistant LG = 8.25" high shoe cover 200/cs (100 pairs) One size fits most

Boot cover

P3450SGY000200LG

Serged seams Elastic openings 8.25˝ height ProShield® 70 fabric Skid resistant 200/cs (100 pairs) One size fits most

Boot cover P3452S

P3452SGYXX010000

Serged seams Elastic openings 10˝ height ProShield® 70 fabric Skid resistant 100/cs (50 pairs) One size fits most

Boot cover

P3454SGYXX010000

Serged seams Elastic openings 18˝ height ProShield® 70 fabric Skid resistant 100/cs (50 pairs) One size fits most

Bound and sewn seams and closures have less barrier than fabric. Serged and/or bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and ProShield® 70 should not be worn when these chemicals are present.

®

Warning: ProShield 70 should not be used around heat, of protection Level flames, sparks or in potentially flammable or explosive environments.

20 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ ProShield® 80 Original name: new garment

Coverall Coverall P8122BBUXX002500 P8125BBUXX002500 Bound seams Bound seams Attached hood (respirator fit)2 Storm flap Elastic hood opening Elastic wrists Storm flap Elastic ankles Elastic wrists Thumb loops Elastic ankles 25/cs Attached boots SM–6X Thumb loops 25/cs SM–6X

Coverall P8127BBUXX002500

P8127B Bound seams Attached hood (respirator fit)2 Hydrophobic outer layer Elastic hood opening Storm flap Comfort fit design and gusset crotch Elastic wrists Elastic ankles Breathable fabric with MVTR Thumb loops measured according to ASTM D6701 25/cs SM–6X Bound seams exceed seam strength requirements as defined in ASTM F3352

Meets the US industry requirements for blood (ASTM F1670) and viral penetration (ASTM F1671)

ProShield® 80 is blue

2Respirator fit hoods are designed with a longer zipper, Note: Not all sizes available in all styles. extending to the chin for complete coverage of the neck Warning: Tyvek® and ProShield® should not be used area. Standard hoods only extend to the neck. around heat, flames, sparks or in potentially flammable See page 7 for photos. ® or explosive environments. Garments made of Tyvek ProShield® 80 Bound and sewn seams and closures have less barrier and ProShield® fabrics should have slip-resistant or anti- than fabric. slip materials on the outer surface of boots, shoe ­covers, or other garment surfaces in conditions where slipping

Serged and/or bound seams are degraded by some of protection Level hazardous liquid chemicals, such as strong acids, and could occur. should not be worn when these chemicals are present.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 21 DuPont™ Tyvek® 400 D Original name: Tyvek® Dual

Coverall Tyvek® 400 D garments provide an TD127S ideal balance of comfort, durability TD125SWBXX0025CM and protection for workers

Serged seams Comfort fit design helps enable a Collar greater range of movement while Zipper closure stretching and bending Storm flap Elastic waist Designed for very specific applications Elastic wrists where demanding comfort Elastic ankles requirements are combined with Thumb loops Front with hood Back limited protective requirements for MD–4X frontal exposures

Coverall Tyvek® 400 fabric on the front Well suited for workers who are and hood involved in a variety of strenuous TD127SWBXX0025CM activities that can lead to heat stress Tyvek® fabric is composed of flashspun in applications that include: Serged seams high-density polyethylene, which Attached hood (respirator fit)2 creates a unique nonwoven material • Wind turbine manufacturing Zipper closure available only from DuPont • Composites manufacturing Storm flap • Boat manufacturing Elastic waist Tyvek® 400 fabric provides an ideal • Remediation Elastic wrists balance of protection, durability and • Utilities Elastic ankles comfort compared to any limited-use • Maintenance Thumb loops fabric technology MD–4X • Glass manufacturing Tyvek® 400 fabric’s durability delivers a consistently better barrier, even Pants after wear and abrasion

TD350SWBXX0025CM Tyvek® 400 is white Serged seams Elastic waist MD–5X ProShield® 10 fabric on the back

ProShield® 10 fabric has been optimized for comfort, softness and breathability

ProShield® 10 fabric is designed for non-hazardous dry particle and light liquid splash applications

ProShield® 10 is made from a polypropylene spunbond-meltblown- spunbond (SMS) fabric

ProShield® 10 is blue

2Respirator fit hoods are designed with a longer zipper, Warning: Tyvek® and ProShield® should not be used extending to the chin for complete coverage of the neck around heat, flames, sparks or in potentially flammable area. Standard hoods only extend to the neck. or explosive environments. Garments made of Tyvek® See page 7 for photos. and ProShield® fabrics should have slip-resistant or anti- Serged and/or bound seams are degraded by some slip materials on the outer surface of boots, shoe ­covers, hazardous liquid chemicals, such as strong acids, and or other garment surfaces in conditions where slipping should not be worn when these chemicals are present. could occur. Note: Not all sizes available in all styles. Certain accessory items are also identified as make to order. Stock/make to order designations are based on ® Tyvek 400 D of protection Level sales volume and production efficiencies. Therefore, designations are subject to change without notice.

22 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tyvek® 400 Original name: Tyvek®

Coverall Coverall Coverall

TY120SWHXX002500 TY122SWHXX002500 TY151SWHXX002500 MD–7X MD–7X Serged seams TY120SWHXX0006G1 TY122SWHXX0006G1 Collar MD–4X MD–4X Snap closure TY120SWHXX0025VP TY122SWHXX0025NF XL–3X MD–7X MD–7X TY120SWHXX0025NF TY122SWHXX0025VP MD–7X MD–7X NAFTA/TAA COMPLIANT Serged seams Serged seams Attached hood (respirator fit)2 An ideal balance of protection, Collar Zipper closure durability and comfort Zipper closure Storm flap Storm flap Elastic waist Comfort fit design allows for a greater Elastic waist Elastic wrists range of motion and fewer blowouts Comfort fit design Elastic ankles Breathable inherent barrier protection Attached skid-resistant boots Coverall Comfort fit design against hazardous dry particles, aerosols and non-hazardous light TY121SWHXX0025NS liquid splash Coverall Serged seams Excellent abrasion resistance; protects TY127SWHXX002500 Collar against hazardous particles down to MD–7X Zipper closure one micron in size Storm flap TY127SWHXX0006G1 Elastic wrists MD–4X When used with other PPE, can help Elastic ankles reduce risk of cross-contamination in TY127SWHXX0025VP Attached skid-resistant boots pandemic response activities MD–7X MD–7X TY127SWHXX0025NF One garment for many applications: Coverall MD–7X NAFTA/TAA COMPLIANT • General maintenance/operations TY125SWHXX002500 Serged seams • Microcrystalline silica MD–7X Attached hood (respirator fit)2 • Lead abatement Zipper closure • Environmental cleanup TY125SWHXX0006G1 Storm flap • Agriculture MD–4X Elastic waist • Asbestos abatement TY125SWHXX0025VP Elastic wrists • Food processing MD–7X Elastic ankles • Mold remediation Comfort fit design • Spray painting Serged seams Collar • Crime scene investigation Zipper closure • Wind turbine manufacturing Storm flap Tyvek® 400 is white Elastic waist Elastic wrists G1 = Reduced case quantity Elastic ankles Comfort fit design NS = Non-skid material

Only NF option codes are NAFTA/TAA compliant. Note: Not all sizes available in all styles. NF = NAFTA/TAA compliant

2 ® ® Respirator fit hoods are designed with a longer zipper, Warning: Tyvek and ProShield should not be used VP = Vend packed extending to the chin for complete coverage of the neck around heat, flames, sparks or in potentially flammable area. Standard hoods only extend to the neck. or explosive environments. Garments made of Tyvek® See page 7 for photos. and ProShield® fabrics should have slip-resistant or anti- Storm flaps: All standard bound and taped seam slip materials on the outer surface of boots, shoe ­covers, coveralls have a single storm flap with a pressure- or other garment surfaces in conditions where slipping sensitive tape closure. Serged seam coveralls do not could occur. have a storm flap. Certain accessory items are also identified as make to Tyvek® 400 Serged and/or bound seams are degraded by some order. Stock/make to order designations are based on Level of protection Level hazardous liquid chemicals, such as strong acids, and sales volume and production efficiencies. Therefore, should not be worn when these chemicals are present. designations are subject to change without notice.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 23 DuPont™ Tyvek® 400 Original name: Tyvek®

Frock Shirt

TY210SWHXX003000 TY303SWHXX005000 SM–7X SM–7X TY210SWHXX0030VP TY303SWHXX0012G1 D–4X MD–4X

Serged seams TY303SWHXX0050VP Collar MD–3X Snap closure Serged seams Collar Snap closure Long sleeve Frock Pants TY211SWHXX003000 TY350SWHXX005000 Serged seams SM–7X Collar TY350SWHXX0012G1 Snap closure MD–4X Elastic wrists TY127S Knee length TY350SWHXX0050VP MD–3X SM–7X Only NF option codes are NAFTA/TAA compliant. Serged seams Bound and sewn seams and closures have less barrier Elastic waist than fabric. Serged and/or bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and Frock Apron should not be worn when these chemicals are present. Note: Not all sizes available in all styles. TY216SWHXX003000 TY273BWHXX010000 Warning: Tyvek® should not be used around heat, Serged seams flames, sparks or in potentially flammable or explosive TY273BWHXX0100VP ® environments. Garments made of Tyvek fabrics should Mandarin collar have slip-resistant or anti-slip materials on the outer Snap closure Bound seams surface of boots, shoe ­covers, or other garment surfaces Elastic wrists Bound neck & ties in conditions where slipping could occur. SM–5X Bib style Certain accessory items are also identified as make to 28˝ x 36˝ order. Stock/make to order designations are based on sales volume and production efficiencies. Therefore, One size fits most designations are subject to change without notice.

Lab coat Sleeves

TY212SWHXX003000 TY500SWHXX020000 SM–7X TY500SWHXX0200NF TY212SWHXX0008G1 NAFTA/TAA COMPLIANT MD–4X TY212SWHXX0030VP Serged seams MD–4X Elastic openings 18˝ length TY212SWHXX0030NF One size fits most SM–7X NAFTA/TAA COMPLIANT Serged seams Collar Hood Snap closure TY657SWHXX010000 Two pockets Serged seams Pullover Elastic face opening Tyvek® 400

Shoulder length of protection Level One size fits most

24 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tyvek® 400 Original name: Tyvek® boot and shoe covers

Shoe cover Boot cover Skid-resistant materials for shoe/boot covers to prevent slipping TY450SWHXX020000 TY454SWHXX0100SR Tyvek® 400 with Friction Coating Tyvek® fabric Tyvek® fabric Serged seams Tyvek® 400 FC sole Tyvek® 400 FC is gray Elastic openings Serged seams 5˝ height Elastic openings LG = 8.25˝ high shoe cover 200/cs (100 pairs) Elastic ankles One size fits most 18˝ height NF = NAFTA/TAA compliant Skid resistant 100/cs (50 pairs) SR = Skid resistant Shoe cover LG–XL TY450SWHXX0200LG

® Tyvek® fabric Shoe cover—Tyvek 400 FC Serged seams FC450SGYXX020000 Elastic openings 8.25˝ height FC450SGYXX0200NF 200/cs (100 pairs) NAFTA/TAA COMPLIANT One size fits most Tyvek® FC fabric Serged seams Boot cover Elastic openings Elastic toe, sole TY452SWHXX010000 and heel seams Tyvek® fabric 5˝ height Serged seams Skid resistant Elastic openings 200/cs (100 pairs) 10˝ height One size fits most 100/cs (50 pairs) One size fits most Boot cover—Tyvek® 400 FC

FC454SGYXX010000 Boot cover Tyvek® FC fabric TY454SWHXX010000 Serged seams Tyvek® fabric Elastic openings Serged seams 18˝ height Elastic openings Skid resistant 18˝ height 100/cs (50 pairs) 100/cs (50 pairs) One size fits most One size fits most

Only NF option codes are NAFTA/TAA compliant. Warning: Tyvek® should not be used around heat, Serged and/or bound seams are degraded by some flames, sparks or in potentially flammable or explosive ® hazardous liquid chemicals, such as strong acids, and environments. Garments made of Tyvek fabrics should should not be worn when these chemicals are present. have slip-resistant or anti-slip materials on the outer surface of boots, shoe ­covers, or other garment surfaces ® Tyvek 400 with Friction Coating (FC) has been specially in conditions where slipping could occur. treated to promote ink/coating adhesion. This treatment lowers the typical bulk liquid holdout values for Tyvek® Certain accessory items are also identified as make to fabric. Products with this treatment offer limited bulk order. Stock/make to order designations are based on Tyvek® 400 liquid holdout. If barrier protection from liquid splash is sales volume and production efficiencies. Therefore, required, please consider a non-treated Tyvek® style or designations are subject to change without notice. of protection Level other substrate.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 25 DuPont™ Tyvek® 400 HV Original name: new garment

Coverall Coverall

TY125SHVXX0025PI TY127SHVXX0025XC SM–3X SM–6X

TY125SHVXX0025XC Serged seams SM–6X Attached hood (respirator fit)2 Zipper closure Serged seams Storm flap Mandarin collar Elastic waist Zipper closure Elastic wrists Elastic waist Elastic ankles Elastic wrists Comfort fit design Elastic ankles 25/cs

TY125S

Durability and breathability of Tyvek®

Ideal when working in dangerous environments, darkness or poor weather conditions

Tyvek® 400 HV is fluorescent orange with retroreflective bands for high visibility

2Respirator fit hoods are designed with a longer zipper, Warning: Tyvek® and ProShield® should not be used extending to the chin for complete coverage of the neck around heat, flames, sparks or in potentially flammable area. Standard hoods only extend to the neck. or explosive environments. Garments made of Tyvek® See page 7 for photos. and ProShield® fabrics should have slip-resistant or anti- Serged and/or bound seams are degraded by some slip materials on the outer surface of boots, shoe ­covers, or other garment surfaces in conditions where slipping hazardous liquid chemicals, such as strong acids, and Tyvek® 400 HV should not be worn when these chemicals are present. could occur. Note: Not all sizes available in all styles. Certain accessory items are also identified as make to order. Stock/make to order designations are based on Level of protection Level sales volume and production efficiencies. Therefore, designations are subject to change without notice.

26 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tyvek® 500 and Tyvek® 600 Original name: Tyvek® Xpert and Tyvek® Plus

2Respirator fit hoods are designed with a longer zipper, extending to the chin for complete coverage of the neck area. Standard hoods only extend to the neck. See page 7 for photos. Bound and sewn seams and closures have less barrier than fabric. Serged and/or bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present. Note: Not all sizes available in all styles. Warning: Tyvek® should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Garments made of Tyvek® fabrics should have slip-resistant or anti-slip materials on the outer surface of boots, shoe ­covers, or other garment surfaces in conditions where slipping could occur. Certain accessory items are also identified as make to order. Stock/make to order designations are based on sales volume and production efficiencies. Therefore, designations are subject to change without notice.

TY198S TY198T

Tyvek® 500 garments are composed of Tyvek® 600 garments are composed of flashspun high-density polyethylene, flashspun high-density polyethylene, which creates a unique, nonwoven which creates a unique, nonwoven material available only from DuPont material available only from DuPont

Suitable for applications such as Tyvek® 600 Type 4/5/6 coveralls offer the pharmaceutical handling, chemical following safety and comfort benefits: processing, automatic spray painting, maintenance and many others • Chemical protective clothing, Category III Type 4-B, 5-B and 6-B Chemical protective clothing, Category III Type 5-B and 6-B • Protection against infective agents (EN 14126), including resistance to Tyvek® 500 is white penetration by blood and body fluids using synthetic blood (ISO 16603)

• Fabric and seams offer chemical permeation barrier to low concentration water-based inorganic chemicals

Tyvek® 600 is white

PI = Packaged individually

Coverall—Tyvek® 500 Coverall—Tyvek® 600

TY198SWHXX0025LA TY198TWHXX0025PI

External serged seams Taped seams Attached hood Attached hood (respirator fit)2 Storm flap Storm flap Elastic wrists Elastic wrists Elastic ankles Elastic ankles CE certified CE certified Category III Type 5-B and 6-B Category III Type 4-B, Packaged individually 5-B and 6-B SM–7X SM–7X Tyvek® 600 Tyvek® 500 Level of protection Level

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 27 DuPont™ Tyvek® 800 Original name: new garment

Coverall Tyvek® 800 garments combine resistance to low-concentration, TJ198TWHXX0025PI water-based, inorganic chemicals Taped seams (even under pressure) with the ® Attached hood (respirator fit)2 durability of Tyvek thanks to their Storm flap innovative fabric technology and Elastic wrists enhanced garment design Elastic ankles CE certified Chemical protective clothing, Category III type 3-B, 4-B, Category III, Type 3-B, 4-B, 5-B 5-B and 6-B and 6-B SM–3X Protection against infective agents (EN 14126), including resistance to penetration by blood and body fluids using synthetic blood (ISO 16603)

Suitable for applications such as industrial cleaning; chemical packaging and redistribution; waste treatment and disposal; environmental remediation and many others

Tyvek® 800 is white

PI = Packaged individually

TJ198T

2Respirator fit hoods are designed with a longer zipper, Warning: Tyvek® should not be used around heat, extending to the chin for complete coverage of the neck flames, sparks or in potentially flammable or explosive area. Standard hoods only extend to the neck. environments. Garments made of Tyvek® fabrics should See page 7 for photos. have slip-resistant or anti-slip materials on the outer Bound and sewn seams and closures have less barrier surface of boots, shoe ­covers, or other garment surfaces Tyvek® 800 than fabric. in conditions where slipping could occur. Serged and/or bound seams are degraded by some Certain accessory items are also identified as make to hazardous liquid chemicals, such as strong acids, and order. Stock/make to order designations are based on should not be worn when these chemicals are present. sales volume and production efficiencies. Therefore, of protection Level designations are subject to change without notice. Note: Not all sizes available in all styles.

28 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 2000 SFR Original name: new garment

Coverall Tychem® 2000 SFR coveralls provide an effective barrier against a range of QS127TGRXX000400 chemicals, as well as secondary flame resistance when worn over primary Taped seams flame resistant (FR) garments like those Attached hood ™ ® Zipper closure made with DuPont Nomex Storm flap with tape closure Provides protection against a Elastic wrists multitude of inorganic acids and Elastic ankles bases as well as a range of industrial SM–7X cleaning formulations

In the event of a , Tychem® 2000 SFR coveralls won’t ignite and Coverall won’t contribute additional burn injury if appropriate primary FR apparel is QS128TGRXX000400 worn beneath

Taped seams Tychem® 2000 SFR garments are 2 Attached hood (respirator fit) appropriate per NFPA 2113 Zipper closure Section 5.1.9 Storm flap with tape closure Elastic wrists Tychem® 2000 SFR is green for 1 Attached socks discretionary purposes and features a Outer boot flaps with elastic low-visibility patch SM–5X newtychem.dupont.com

Combo suit (jacket and bib overall)

QS750TGRXX000400 QS127 Jacket Taped seams Mandarin collar Elastic wrists Apron Double storm flap with hook-and- QS275TGRXX001200 loop closure Taped seams Hook-and-loop neck closure Bib overall Waist ties Taped seams Elastic wrists Adjustable straps with closure 44" long SM–4X SM–5X

Please note that Tychem® fabrics have different area. Standard hoods only extend to the neck. permeation performance. Please check SafeSPEC™ See page 7 for photos. for permeation data that meets your specific needs. Seams and closures have less barrier than fabric. Stock/make to order designations are based on Serged and/or bound seams are degraded by some sales volume and production efficiencies. Therefore, hazardous liquid chemicals, such as strong acids, and designations are subject to change without notice. should not be worn when these chemicals are present.

1These Tychem® 2000 SFR garments have attached socks Note: Not all sizes available in all styles. made of the garment material. These attached socks Warning: Tychem® 2000 SFR garments provide must be worn inside protective outer footwear and are secondary flame resistance; they must be worn ® not suitable as outer footwear. These attached socks over appropriate primary flame-resistant garments Tychem 2000 SFR do not have adequate durability or slip resistance to be (such as Nomex® IIIA). Tychem® 2000 SFR garments worn as the outer foot covering. should not be worn alone in areas where flame Level of protection Level 2Respirator fit hoods are designed with a longer zipper, exposure may occur. extending to the chin for complete coverage of the neck

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 29 DuPont™ Tychem® 2000 Original name: Tychem® QC

Light liquid splash protection Coverall Coverall Used extensively in the QC120SYLXX001200 QC125BYLXX001200 petroleum; pulp and ; Bound seams, MD–6X food and chemical processing; Serged seams and pharmaceutical industries Collar QC125TYLXX000400 Taped seams, MD–5X Zipper closure Tychem® 2000 is polyethylene-coated MD–7X Collar Tyvek® fabric Zipper closure Storm flap with tape closure Flexible, durable and lightweight Elastic wrists ® Elastic ankles Tychem 2000 provides at least 30 minutes of protection against >40 chemical challenges Coverall Coverall When used with other PPE, can help QC120BYLXX001200 QC125SYLXX001200 reduce the risk of cross-contamination in pandemic preparedness activities Bound seams Serged seams Collar Collar Meets ASTM F1670 and ASTM F1671 Zipper closure Zipper closure tests, offering bloodborne pathogen Storm flap with tape closure Storm flap protection MD–6X Elastic wrists Elastic ankles Tychem® 2000 is yellow for high visibility MD–7X

Only BN option codes are Berry Amendment compliant. Please note that Tychem® fabrics have different permeation performance. Please check SafeSPEC™ Coverall Coverall for permeation data that meets your specific needs. Stock/make to order designations are based on QC122BYLXX001200 QC127BYLXX001200 sales volume and production efficiencies. Therefore, Bound seams Bound seams, MD–6X designations are subject to change without notice. 1These Tychem® 2000 garments have attached socks QC122BYLXX0012BN QC127TYLXX000400 made of the garment material. These attached socks Bound seams Taped seams, MD–5X must be worn inside protective outer footwear and are BERRY AMENDMENT not suitable as outer footwear. These attached socks COMPLIANT Attached hood do not have adequate durability or slip resistance to be worn as the outer foot covering. QC122TYLXX000400 Zipper closure Storm flap Seams and closures have less barrier than fabric. Taped seams Elastic wrists Serged and/or bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and Attached hood Elastic ankles should not be worn when these chemicals are present. Zipper closure Note: Not all sizes available in all styles. Storm flap with tape closure Warning: Most Tychem® garments should not be used Elastic wrists around heat, flames, sparks or in potentially flammable Attached socks1 or explosive environments. Only Tychem® 6000 FR and Tychem® 10000 FR garments are designed and tested MD–6X to help reduce injury during escape from a flash fire. Tychem® 2000 SFR garments offer secondary flame resistance and are designed to be used over primary Coverall Coverall flame-resistant garments such as Nomex® IIIA. Users of Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 QC122SYLXX001200 QC127SYLXX001200 SFR garments should not knowingly enter an explosive environment. Consult the Tychem® user manual, located Serged seams Serged seams on our website, for instructions on proper use, care Attached hood Attached hood and maintenance of your Tychem® garments. Zipper closure Zipper closure Storm flap Elastic wrists Elastic wrists Elastic ankles Attached socks1 MD–7X MD–7X Tychem® 2000 Level of protection Level

30 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 2000 Original name: Tychem® QC

Apron Apron

QC273BYLXX010000 QC278BYLXX001200

Bound neck & ties Bound seams Bib style Attached long sleeves 36˝ long Bound yoke neck without snaps One size fits most Waist ties Elastic wrists 52˝ long One size fits most

Apron Sleeve

QC275BYLXX002500 QC500BYLXX020000

Bound seams Bound seams Raw edge neck with snaps Elastic openings Attached long sleeves 18˝ length Waist ties One size fits most Elastic wrists 44˝ long SM–4X

Apron

QC275BYLXX0025HL

Bound seams QC127 Hook-and-loop neck closure Attached long sleeves Waist ties Elastic wrists 44˝ long SM–4X

Only BN option codes are Berry Amendment compliant. Note: Not all sizes available in all styles. Please note that Tychem® fabrics have different Warning: Most Tychem® garments should not be used permeation performance. Please check SafeSPEC™ around heat, flames, sparks or in potentially flammable for permeation data that meets your specific needs. or explosive environments. Only Tychem® 6000 FR and ® Stock/make to order designations are based on Tychem 10000 FR garments are designed and tested sales volume and production efficiencies. Therefore, to help reduce injury during escape from a flash fire. ® designations are subject to change without notice. Tychem 2000 SFR garments offer secondary flame resistance and are designed to be used over primary 1 ® These Tychem 2000 garments have attached socks flame-resistant garments such as Nomex® IIIA. Users of made of the garment material. These attached socks Tychem® 6000 FR, Tychem® 10000 FR, and Tychem® 2000 must be worn inside protective outer footwear and are SFR garments should not knowingly enter an explosive not suitable as outer footwear. These attached socks environment. Consult the Tychem® user manual, located do not have adequate durability or slip resistance to be on our website, for instructions on proper use, care and Tychem® 2000 worn as the outer foot covering. maintenance of your Tychem® garments. Seams and closures have less barrier than fabric. Serged and/or bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and Level of protection Level should not be worn when these chemicals are present.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 31 DuPont™ Tychem® 4000 Original name: Tychem® SL

Coverall Coverall

SL120BWHXX001200 SL122BWHXX001200 Bound seams, MD–7X Bound seams Collar SL122TWHXX000600 Zipper closure Taped seams, MD–6X Storm flap with tape closure Attached hood MD–6X Zipper closure Storm flap with tape closure Elastic wrists Attached socks1

Coverall Coverall SL127B

SL125BWHXX001200 SL127BWHXX001200 Bound seams, MD–6X Bound seams, MD-7X Effective protection against a range of chemicals SL125TWHXX000600 SL127TWHXX000600 Taped seams, MD–5X Taped seams, MD-7X Uses include , hazardous response and Collar Attached hood Zipper closure Zipper closure nuclear environments Storm flap with tape closure Storm flap with tape closure Tychem® 4000 is laminated to Elastic wrists Elastic wrists Tyvek® fabric Elastic ankles Elastic ankles Rugged and durable

Coverall Coverall Tychem® 4000 is white for high visibility

SL121BWHXX001200 SL127TWHXX0006RF Tychem® 4000 provides at least 30 Bound seams, MD–6X Taped seams, SM-7X minutes of protection against >120 SL121TWHXX000400 Attached hood (respirator fit)2 chemical challenges Taped seams, MD–5X Zipper closure Storm flap with tape closure When used with other PPE, can help Collar Elastic wrists reduce the risk of cross-contamination Zipper closure Elastic ankles in pandemic preparedness activities Storm flap with tape closure Elastic wrists Meets ASTM F1670 and ASTM F1671 Attached socks1 tests, offering bloodborne pathogen protection Coverall Stock/make to order designations are based on Tychem® 2000 SFR garments offer secondary flame SL122BWHXX0012BN sales volume and production efficiencies. Therefore, resistance and are designed to be used over primary Bound seams designations are subject to change without notice. flame-resistant garments such as Nomex® IIIA. Users of ® ® ® 1 ® Tychem 6000 FR, Tychem 10000 FR and Tychem 2000 BERRY AMENDMENT These Tychem 4000 garments have attached socks made of the garment material. These attached socks SFR garments should not knowingly enter an explosive COMPLIANT ® must be worn inside protective outer footwear and are environment. Consult the Tychem user manual, located SL122TWHXX0006BN not suitable as outer footwear. These attached socks on our website, for instructions on proper use, care and ® Taped seams do not have adequate durability or slip resistance to be maintenance of your Tychem garments. BERRY AMENDMENT worn as the outer foot covering. COMPLIANT 2Respirator fit hoods are designed with a longer zipper, Attached hood extending to the chin for complete coverage of the neck area. Standard hoods only extend to the neck. Zipper closure See page 7 for photos. Storm flap with tape closure Seams and closures have less barrier than fabric. Elastic wrists Serged and/or bound seams are degraded by some 1 Attached socks hazardous liquid chemicals, such as strong acids, and ® MD–7X should not be worn when these chemicals are present. Tychem 4000 Note: Not all sizes available in all styles. Only BN option codes are Berry Amendment compliant. Warning: Most Tychem® garments should not be used

® around heat, flames, sparks or in potentially flammable Please note that Tychem fabrics have different ® ™ or explosive environments. Only Tychem 6000 FR and permeation performance. Please check SafeSPEC of protection Level Tychem® 10000 FR garments are designed and tested for permeation data that meets your specific needs. to help reduce injury during escape from a flash fire.

32 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 4000 Original name: Tychem® SL

Coverall

SL128TWHXX000600

Taped seams Attached hood (respirator fit)2 Zipper closure Storm flap with tape closure Elastic wrists Attached socks1 Outer boot flaps with elastic SM–5X

Apron

SL274BWHXX005000

Bound neck & ties Bib style 36˝ long One size fits most

SL120B SL122T

Apron Apron Apron

SL275TWHXX002500 SL275TWHXX0025HL SL278BWHXX001200

Taped seams Taped seams Bound seams Raw edge neck with snaps Hook-and-loop neck closure Bound yoke neck with snaps Attached long sleeves Attached long sleeves Attached long sleeves Waist ties Waist ties Waist ties Elastic wrists Elastic wrists Elastic wrists 44˝ long 44˝ long 52˝ long SM–4X One size fits most One size fits most

Apron

SL278BWHXX0012HL

Bound seams Hook-and-loop neck closure Attached long sleeves Seams and closures have less barrier than fabric. Waist ties Serged and/or bound seams are degraded by some Elastic wrists hazardous liquid chemicals, such as strong acids, and 52˝ long should not be worn when these chemicals are present. One size fits most Note: Not all sizes available in all styles. Warning: Most Tychem® garments should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Only Tychem® 6000 FR and Tychem® 10000 FR garments are designed and tested to help reduce injury during escape from a flash fire. Tychem® 4000 Tychem® 2000 SFR garments offer secondary flame resistance and are designed to be used over primary ® Please note that Tychem fabrics have different flame-resistant garments such as Nomex® IIIA. Users of ™ permeation performance. Please check SafeSPEC Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 for permeation data that meets your specific needs. SFR garments should not knowingly enter an explosive ®

Stock/make to order designations are based on environment. Consult the Tychem user manual, located of protection Level sales volume and production efficiencies. Therefore, on our website, for instructions on proper use, care and designations are subject to change without notice. maintenance of your Tychem® garments.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 33 DuPont™ Tychem® 5000 Original name: Tychem® CPF 3

Coverall Strong and durable garments with broad chemical barrier C3122TTNXX0006BN SM–5X Tychem® 5000 is a multi-layer barrier BERRY AMENDMENT film laminated to a durable fabric COMPLIANT C3122TTNXX000600 Tychem® 5000 provides at least 30 SM–7X minutes of protection against >145 chemical challenges Taped seams Attached hood Uses include chemical and Zipper closure petrochemical handling, hazardous Storm flap with tape closure materials/waste cleanup, industrial Elastic wrists Hazmat teams, utilities and Attached socks1 domestic preparedness

Coverall Tychem® 5000 is tan for discretionary purposes and features C3125TTNXX000600 a low-visibility patch

Taped seams Tychem® 5000 198T/199T are certified to Collar NFPA 1992, Standard on Liquid Splash- Zipper closure Protective Ensembles and Clothing for Storm flap with tape closure Hazardous Materials Emergencies Elastic wrists Elastic ankles SM–5X C3127T

Apron Coverall C3275TTNXX000600 C3127TTNXX000600 Taped seams Taped seams Bound snap neck Attached hood Attached long sleeves Zipper closure Waist ties Storm flap with tape closure Elastic wrists Elastic wrists 44˝ long Elastic ankles SM–4X SM–7X

Please note that Tychem® fabrics have different Warning: Most Tychem® garments should not be used permeation performance. Please check SafeSPEC™ around heat, flames, sparks or in potentially flammable for permeation data that meets your specific needs. or explosive environments. Only Tychem® 6000 FR and ® Coverall Stock/make to order designations are based on Tychem 10000 FR garments are designed and tested sales volume and production efficiencies. Therefore, to help reduce injury during escape from a flash fire. ® C3128TTNXX000600 designations are subject to change without notice. Tychem 2000 SFR garments offer secondary flame resistance and are designed to be used over primary 1 ® These Tychem 5000 garments have attached socks ® C3128TTNXX0006BN flame-resistant garments such as Nomex IIIA. Users of made of the garment material. These attached socks Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 BERRY AMENDMENT must be worn inside protective outer footwear and are SFR garments should not knowingly enter an explosive COMPLIANT not suitable as outer footwear. These attached socks environment. Consult the Tychem® user manual, do not have adequate durability or slip resistance to be located on our website, for instructions C3128TTNXX00062K worn as the outer foot covering. on proper use, care and 2Respirator fit hoods are designed with a longer zipper, maintenance of your Taped seams extending to the chin for complete coverage of the neck Tychem® garments. 2 area. Standard hoods only extend to the neck. Attached hood (respirator fit) ® See page 7 for photos. Tychem 5000 Zipper closure Storm flaps: All taped seam coveralls have a storm flap Storm flap with tape closure or double storm flap, see product description for details. Elastic wrists Seams and closures have less barrier than fabric. Attached socks1 Note: Not all sizes available in all styles. Outer boot flaps with elastic Level of protection Level SM–5X

34 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 5000 Original name: Tychem® CPF 3

Coverall—HD design Coverall HD design— certified to NFPA 1992 C3184TTNXX000600 C3198TTNXX0006WG Taped seams Collar Taped seams Zipper closure Attached hood (respirator fit)2 Double storm flaps with Zipper closure hook-and-loop closure Double storm flaps with Attached jam fit removable/ hook-and-loop closure field replaceable neoprene outer/ Attached Guardian™ butyl outer/ multi-layer laminate inner gloves multi-layer laminate inner gloves Attached socks1 Elastic ankles Outer boot flaps SM–5X SM–4X Coverall HD design— Coverall—HD design certified to NFPA 1992

C3185TTNXX000600 C3199TTNXX000600

Taped seams C3199TTNXX0006BN Attached hood (respirator fit)2 BERRY AMENDMENT COMPLIANT Zipper closure Double storm flaps with Taped seams hook-and-loop closure Attached hood (respirator fit)2 C3199T Attached jam fit removable/ Zipper closure field replaceable neoprene outer/ Tychem® 5000 HD garments are multi-layer laminate inner gloves Double storm flaps with hook-and-loop closure intended for use by law enforcement, Attached socks1 Elastic wrists Hazmat and hospital personnel Outer boot flaps Attached socks1 SM–4X Outer boot flaps Offered in respirator fit hood or collar SM–5X style for use with a PAPR; ideal for hospital first receiver applications Coverall HD design— Coverall HD design— certified to NFPA 1992 Tychem® 5000 HD garments may certified to NFPA 1992 C3198TTNXX000600 include integrated gloves and improved C3199TTNXX0006WG closures to reduce response time; C3198TTNXX0006BN deliver a high level of dexterity and Taped seams tactility; and improve protection Taped seams Attached hood (respirator fit)2 2 Attached hood (respirator fit) Zipper closure Tychem® 5000 HD is tan for Zipper closure Double storm flaps with discretionary purposes and features Double storm flaps with hook-and-loop closure a low-visibility patch hook-and-loop closure Attached Guardian™ butyl outer/ Elastic wrists multi-layer laminate inner gloves Elastic ankles Attached socks1 SM–5X Outer boot flaps SM–5X

Only BN option codes are Berry Amendment compliant. Storm flaps: All taped seam coveralls have a storm flap Please note that Tychem® fabrics have different or double storm flap, see product description for details. permeation performance. Please check SafeSPEC™ Seams and closures have less barrier than fabric. for permeation data that meets your specific needs. Note: Not all sizes available in all styles. Stock/make to order designations are based on sales Warning: Most Tychem® garments should not be used volume and production efficiencies. Therefore, around heat, flames, sparks or in potentially flammable designations are subject to change without notice. or explosive environments. Only Tychem® 6000 FR and 1These Tychem® 5000 garments have attached socks Tychem® 10000 FR garments are designed and tested made of the garment material. These attached socks to help reduce injury during escape from a flash fire. Tychem® 5000 must be worn inside protective outer footwear and are Tychem® 2000 SFR garments offer secondary flame not suitable as outer footwear. These attached socks resistance and are designed to be used over primary do not have adequate durability or slip resistance to be flame-resistant garments such as Nomex® IIIA. Users of worn as the outer foot covering. Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 2Respirator fit hoods are designed with a longer zipper, SFR garments should not knowingly enter an explosive environment. Consult the Tychem® user manual, located

extending to the chin for complete coverage of the neck of protection Level area. Standard hoods only extend to the neck. on our website, for instructions on proper use, care and ® See page 7 for photos. maintenance of your Tychem garments.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 35 DuPont™ Tychem® 5000 Original name: Tychem® CPF 3

Hood Combo suit (jacket and bib overall)

C3651TTNXX000600 C3750TTNXX000600

Taped seams Jacket EX (extra-wide) faceshield Taped seams (20 mil PVC) Mandarin collar Pullover Zipper closure Hook-and-loop waist closure Jam fit cuff One size fits most Double storm flaps

Bib overall Bib overall Taped seams Adjustable webbing C3360TTNXX000600 straps with closure Taped seams SM–4X Adjustable webbing straps with closure SM–4X

Jacket C3122T

C3670TTNXX000600 C3670TTNXX0006JF

Taped seams Mandarin collar Zipper closure Double storm flaps with hook-and-loop closure Elastic wrists SM–4X

Please note that Tychem® fabrics have different Warning: Most Tychem® garments should not be used permeation performance. Please check SafeSPEC™ around heat, flames, sparks or in potentially flammable for permeation data that meets your specific needs. or explosive environments. Only Tychem® 6000 FR and Tychem® 10000 FR garments are designed and tested Stock/make to order designations are based on Tychem® 5000 sales volume and production efficiencies. Therefore, to help reduce injury during escape from a flash fire. ® designations are subject to change without notice. Tychem 2000 SFR garments offer secondary flame resistance and are designed to be used over primary Storm flaps: All taped seam coveralls have a storm flap flame-resistant garments such as Nomex® IIIA. Users of or double storm flap, see product description for details. Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 Seams and closures have less barrier than fabric. SFR garments should not knowingly enter an explosive ®

environment. Consult the Tychem user manual, located of protection Level Note: Not all sizes available in all styles. on our website, for instructions on proper use, care and maintenance of your Tychem® garments.

36 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 5000 Original name: Tychem® CPF 3

Encapsulated Level B Encapsulated Level B

C3525TTNXX000600 C3526TTNXX000600

Front entry Rear entry Taped seams Taped seams Standard faceshield (20 mil PVC) Standard faceshield (20 mil PVC) Zipper closure Zipper closure Double storm flaps with Double storm flaps with hook-and-loop closure hook-and-loop closure Flat back with one exhaust Flat back with one exhaust Rear vent (airline access) vent (airline access) entry Elastic wrists Front Elastic wrists Elastic ankles entry Attached socks1 Air access left side Outer boot flaps SM–4X SM–4X

Encapsulated Level B

C3528TTNXX000600

Rear entry Taped seams Standard faceshield (20 mil PVC) Zipper closure Double storm flaps with hook-and-loop closure Two exhaust vents Rear Expanded back entry Elastic wrists Attached socks1 Outer boot flaps SM–4X

Please note that Tychem® fabrics have different Seams and closures have less barrier than fabric. ™ permeation performance. Please check SafeSPEC Note: Not all sizes available in all styles. for permeation data that meets your specific needs. Warning: Most Tychem® garments should not be used Stock/make to order designations are based on around heat, flames, sparks or in potentially flammable sales volume and production efficiencies. Therefore, or explosive environments. Only Tychem® 6000 FR and designations are subject to change without notice. Tychem® 10000 FR garments are designed and tested 1These Tychem® 5000 garments have attached socks to help reduce injury during escape from a flash fire. Tychem® 5000 made of the garment material. These attached socks Tychem® 2000 SFR garments offer secondary flame must be worn inside protective outer footwear and are resistance and are designed to be used over primary not suitable as outer footwear. These attached socks flame-resistant garments such as Nomex® IIIA. Users of do not have adequate durability or slip resistance to be Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 worn as the outer foot covering. SFR garments should not knowingly enter an explosive environment. Consult the Tychem® user manual, located

Storm flaps: All taped seam coveralls have a storm flap of protection Level or double storm flap, see product description for details. on our website, for instructions on proper use, care and maintenance of your Tychem® garments.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 37 DuPont™ Tychem® 6000 Original name: Tychem® F

Coverall Widely used by military personnel and first responders for chemical TF125TGY2X0006TV warfare agent situations TAA COMPLIANT Strong and durable with a broad Taped seams chemical barrier Collar Zipper closure For use when potential exposure Storm flap with tape closure to industrial chemicals and Elastic wrists chemical warfare agents exists Elastic ankles SM–5X Successfully tested by Edgewood Chemical Biological Center in Aberdeen, MD Coverall Tychem® 6000 is a barrier film TF145TGYXX0006TV laminated to Tyvek® TAA COMPLIANT Tychem® 6000 provides at least TF145TGYXX000600 30 minutes of protection against >180 chemical challenges Taped seams Attached hood (respirator fit)2 Tychem® 6000 is available in Zipper closure orange for high visibility and gray Storm flap with tape closure for discretionary purposes with Elastic wrists a low-visibility patch Elastic ankles SM–5X Tychem® 6000 TF199T and TF611T TF611T are certified to NFPA 1992, Standard on Liquid Splash-Protective Coverall Coverall Ensembles and Clothing for Hazardous Materials Emergencies TF169TGYXX0006TV TF186TGYXX0006PI TAA COMPLIANT Taped seams 2 TF169TGYXX000600 Attached hood (respirator fit) Zipper closure Taped seams Storm flap with tape closure Coverall— Attached hood (respirator fit)2 Attached butyl gloves certified to NFPA 1992 Zipper closure Attached socks1 Storm flap with tape closure Outer boot flaps TF199TGYXX0006WG Elastic wrists MD–5X Attached socks1 Taped seams 2 SM–5X Attached hood (respirator fit) Zipper closure Storm flap with tape closure Attached butyl gloves Attached socks1 Only TV option codes are TAA compliant. Storm flaps: All taped seam coveralls have a storm flap Outer boot flaps ® or double storm flap, see product description for details. Please note that Tychem fabrics have different MD–5X permeation performance. Please check SafeSPEC™ Seams and closures have less barrier than fabric. for permeation data that meets your specific needs. Note: Not all sizes available in all styles. Stock/make to order designations are based on Warning: Most Tychem® garments should not be used sales volume and production efficiencies. Therefore, around heat, flames, sparks or in potentially flammable designations are subject to change without notice. or explosive environments. Only Tychem® 6000 FR and 1These Tychem® 6000 garments have attached socks Tychem® 10000 FR garments are designed and tested made of the garment material. These attached socks to help reduce injury during escape from a flash fire. must be worn inside protective outer footwear and are Tychem® 2000 SFR garments offer secondary flame Tychem® 6000 not suitable as outer footwear. These attached socks resistance and are designed to be used over primary do not have adequate durability or slip resistance to be flame-resistant garments such as Nomex® IIIA. Users of worn as the outer foot covering. Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 2Respirator fit hoods are designed with a longer zipper, SFR garments should not knowingly enter an explosive ® extending to the chin for complete coverage of the neck environment. Consult the Tychem user manual, located on our website, for instructions on proper use, care and

area. Standard hoods only extend to the neck. of protection Level ® See page 7 for photos. maintenance of your Tychem garments.

38 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 6000 Original name: Tychem® F

Coverall— Apron certified to NFPA 1992 TYFPA30SGYXX002500 TF611TGYXX0001NF No seams Taped seams Neck and waist ties Elastomeric faceseal Partial body chemical Rear entry protective clothing, Category III, Type PB [3] Horizontal zipper EN 14126 (barrier to Attached multi-layer infective agents) laminate gloves 1 EN 1149-1 Attached socks (antistatic treatment on inside) Outer boot flaps Shin length Reinforced waist and knees One size fits most for added protection SM–5X Sleeves

Coverall TYFPS32SGYXX005000

TYFCHA5TORXX002500 Taped seam Elastic openings Taped seams 18˝ length 2 Attached hood (respirator fit) Partial body chemical Zipper closure protective clothing, Storm flap with tape closure Category III, Type PB [3] Elastic wrists EN 14126 (barrier to infective agents) Elastic ankles TYFPL5 Thumb loops EN 1149-1 (antistatic treatment on inside) Chin flap One size fits most Chemical protective clothing, Category III, Type 3-B, 4-B, 5-B and 6-B EN 14126 (barrier to infective agents) Gown EN 1073-2 (protection against radioactive contamination) TYFPL50SGYXX002500 EN 1149-5 (antistatic treatment on inside) MD–2X Taped seams Wrap-over rear closure with tie Partial body chemical protective clothing, Category III, Type PB [3] Shin length SM/MD and LG/2X

Please note that Tychem® fabrics have different Seams and closures have less barrier than fabric. ™ permeation performance. Please check SafeSPEC Note: Not all sizes available in all styles. for permeation data that meets your specific needs. Warning: Most Tychem® garments should not be used Stock/make to order designations are based on around heat, flames, sparks or in potentially flammable sales volume and production efficiencies. Therefore, or explosive environments. Only Tychem® 6000 FR and designations are subject to change without notice. Tychem® 10000 FR garments are designed and tested 1These Tychem® 6000 garments have attached socks to help reduce injury during escape from a flash fire. made of the garment material. These attached socks Tychem® 2000 SFR garments offer secondary flame must be worn inside protective outer footwear and are resistance and are designed to be used over primary Tychem® 6000 not suitable as outer footwear. These attached socks flame-resistant garments such as Nomex® IIIA. Users of do not have adequate durability or slip resistance to be Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 worn as the outer foot covering. SFR garments should not knowingly enter an explosive ® 2Respirator fit hoods are designed with a longer zipper, environment. Consult the Tychem user manual, located extending to the chin for complete coverage of the neck on our website, for instructions on proper use, care and ® area. Standard hoods only extend to the neck. maintenance of your Tychem garments. of protection Level See page 7 for photos.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 39 DuPont™ Tychem® 6000 FR Original name: Tychem® ThermoPro

Coverall— certified to NFPA 1992 and NFPA 2112 and meets Flame-resistant (FR) NFPA 70E Category 2 Provides triple hazard protection TP198TGYXX000200 from chemicals, flash fire and electric arc, combining the trusted chemical TP198TGYXX0002BN protection of Tychem® with the flame BERRY AMENDMENT ® COMPLIANT and arc flash protection of Nomex into a single garment TP198TORXX000200 Tychem® 6000 FR 198T/199T meet the TP198TORXX0002BN requirements of NFPA 1992 Standard BERRY AMENDMENT on Liquid-Splash Protective Ensembles COMPLIANT and Clothing for Hazardous Materials Taped seams Emergencies Attached hood with drawstring (respirator fit)2 NFPA 2112, Standard on Flame-Resistant Zipper closure Clothing for Protection of Industrial Double storm flaps with Personnel Against Short-Duration hook-and-loop closure Thermal Exposures from Fire Elastic wrists Hemmed ankles SM–5X

TP198T ® Coverall— Tychem 6000 FR 198T/199T exceed certified to NFPA 1992 and the Hazard Risk Category 2 requirement NFPA 2112 and meets of 8 cal/cm2 outlined in NFPA 70E, NFPA 70E Category 2 Standard for Electrical Safety in the Workplace TP199TGYXX000200 Constructed for heavy use, yet TP199TGYXX0002BN lightweight and easy to wear BERRY AMENDMENT Only BN option codes are Berry Amendment compliant. COMPLIANT ® Please note that Tychem® fabrics have different Tychem 6000 FR provides at least ™ 30 minutes of protection against >180 TP199TORXX000200 permeation performance. Please check SafeSPEC for permeation data that meets your specific needs. chemical challenges TP199TORXX0002BN Stock/make to order designations are based on sales volume and production efficiencies. Therefore, ® BERRY AMENDMENT Tychem 6000 FR has an arc rating designations are subject to change without notice. COMPLIANT of 15 cal/cm2 Ebt 1These Tychem® 6000 FR garments have attached socks Taped seams made of the garment material. These attached socks Tychem® 6000 FR is available in must be worn inside protective outer footwear and are Attached hood with not suitable as outer footwear. These attached socks orange for high visibility and gray drawstring (respirator fit)2 do not have adequate durability or slip resistance to be for discretionary purposes with a Zipper closure worn as the outer foot covering. low-visibility patch Double storm flaps 2Respirator fit hoods are designed with a longer zipper, with hook-and-loop closure extending to the chin for complete coverage of the Elastic wrists neck area. Standard hoods only extend to the neck. Attached socks1 See page 7 for photos. Outer boot flaps Seams and closures have less barrier than fabric. SM–5X Note: Not all sizes available in all styles. Warning: Most Tychem® garments should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Only Tychem® 6000 FR and Tychem® 10000 FR garments are designed and tested Tychem® 6000 FR to help reduce injury during escape from a flash fire. Tychem® 2000 SFR garments offer secondary flame resistance and are designed to be used over primary flame-resistant garments such as Nomex® IIIA. Users of Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 SFR garments should not knowingly enter an explosive environment. Consult the Tychem® user manual, located on our website, for instructions on proper use, care and Level of protection Level maintenance of your Tychem® garments.

40 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 6000 FR Original name: Tychem® ThermoPro

Backless coverall Sleeved apron

TP800TORXX000200 TP275TGYXX000200

Open back coverall TP275TORXX000200 Buckle closure around waist Taped seams Snap closure around neck Two buckle closure system LG–5X 45˝ long SM–4X

Combo suit (jacket and bib overall) Apron

TP750TGYXX000200 TP284TGYXX000400 TP750TORXX000200 TP284TORXX000400

Jacket Taped seams Taped seams Sleeveless apron Mandarin collar Buckle closure system Zipper closure Waist strap Elastic wrists SM–4X Double storm flaps TP750T with hook–and–loop closure and elastic at waist (jacket)

Bib overall Taped seams Adjustable webbing straps with buckle closure SM–4X

Please note that Tychem® fabrics have different Warning: Most Tychem® garments should not be used permeation performance. Please check SafeSPEC™ around heat, flames, sparks or in potentially flammable ® for permeation data that meets your specific needs. or explosive environments. Only Tychem 6000 FR and Tychem® 6000 FR ® Stock/make to order designations are based on Tychem 10000 FR garments are designed and tested sales volume and production efficiencies. Therefore, to help reduce injury during escape from a flash fire. ® designations are subject to change without notice. Tychem 2000 SFR garments offer secondary flame resistance and are designed to be used over primary Seams and closures have less barrier than fabric. flame-resistant garments such as Nomex® IIIA. Users of Note: Not all sizes available in all styles. Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 SFR garments should not knowingly enter an explosive ®

environment. Consult the Tychem user manual, located of protection Level on our website, for instructions on proper use, care and maintenance of your Tychem® garments.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 41 DuPont™ Tychem® 9000 Original name: Tychem® BR

Encapsulated Level A Broad protection for hazardous material handlers BR557TYLXX00017R Uses include chemical handling Rear entry and petrochemical manufacturing Taped seams EX (extra–wide) three-layer Tychem® 9000 is a multi-layer composite faceshield (PVC 40 mil/ Teflon™ 5 mil/PVC 20 mil) barrier laminated to a strong, nonwoven substrate Gas-tight PVC zipper closure Rear Double storm flaps with entry hook–and–loop closure Tear-, puncture- and abrasion-resistant Two exhaust valves for lasting, consistent protection Flat back ® Internal adjustment belt Tychem 9000 provides at least 30 Attached internal multi-layer minutes of protection against >280 laminate gloves chemical challenges Attached butyl gloves ® Attached socks1 Tychem 9000 is yellow for Outer boot flaps with elastic high visibility XL–4X

Encapsulated Level B

BR528TYLXX000100

Rear entry Taped seams Standard faceshield (20 mil PVC) Zipper closure BR528T Double storm flaps Rear with hook-and-loop closure entry Two exhaust vents Expanded back Elastic wrists Attached socks1 Outer boot flaps with elastic MD–4X

Please note that Tychem® fabrics have different Seams and closures have less barrier than fabric. ™ permeation performance. Please check SafeSPEC Note: Not all sizes available in all styles. for permeation data that meets your specific needs. Warning: Most Tychem® garments should not be used Stock/make to order designations are based on around heat, flames, sparks or in potentially flammable sales volume and production efficiencies. Therefore, or explosive environments. Only Tychem® 6000 FR and Tychem® 9000 designations are subject to change without notice. Tychem® 10000 FR garments are designed and tested 1These Tychem® 9000 garments have attached socks to help reduce injury during escape from a flash fire. made of the garment material. These attached socks Tychem® 2000 SFR garments offer secondary flame must be worn inside protective outer footwear and are resistance and are designed to be used over primary not suitable as outer footwear. These attached socks flame-resistant garments such as Nomex® IIIA. Users of do not have adequate durability or slip resistance to be Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 worn as the outer foot covering. SFR garments should not knowingly enter an explosive ® Storm flaps: All taped seam coveralls have a single environment. Consult the Tychem user manual, located storm flap with a pressure-sensitive tape closure. on our website, for instructions on proper use, care and of protection Level maintenance of your Tychem® garments.

42 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 9000 Original name: Tychem® BR

Coverall Hood

BR125TYLXX000200 BR651TYLXX000200

Taped seams Taped seams Collar Standard faceshield Zipper closure (20 mil PVC) Double storm flaps Pullover with tape closure Hook-and-loop waist closure Elastic wrists One size fits most Elastic ankles SM–5X

Coverall Combo suit (jacket and bib overall)

BR127TYLXX000200 BR753TYLXX000600 SM–6X Jacket BR127TYLXX0002BN Taped seams SM–5X Mandarin collar BERRY AMENDMENT Zipper closure COMPLIANT Jam cuff Taped seams Double storm flaps Attached hood (respirator fit)2 Zipper closure Bib overall Double storm flaps Taped seams with tape closure Adjustable webbing Elastic wrists straps with closure BR128T Elastic ankles Packaged individually SM–4X Coverall

BR128TYLXX000200 BR128TYLXX0002BN

BERRY AMENDMENT COMPLIANT

Taped seams Attached hood (respirator fit)2 Zipper closure Double storm flaps with tape closure Elastic wrists Attached socks1 Outer boot flaps with elastic SM–7X

Only BN option codes are Berry Amendment compliant. Storm flaps: All taped seam coveralls have a single Please note that Tychem® fabrics have different storm flap with a pressure-sensitive tape closure. permeation performance. Please check SafeSPEC™ Seams and closures have less barrier than fabric. for permeation data that meets your specific needs. Note: Not all sizes available in all styles. Stock/make to order designations are based on Warning: Most Tychem® garments should not be used sales volume and production efficiencies. Therefore, around heat, flames, sparks or in potentially flammable designations are subject to change without notice. or explosive environments. Only Tychem® 6000 FR and 1These Tychem® 9000 garments have attached socks Tychem® 10000 FR garments are designed and tested Tychem® 9000 made of the garment material. These attached socks to help reduce injury during escape from a flash fire. must be worn inside protective outer footwear and are Tychem® 2000 SFR garments offer secondary flame not suitable as outer footwear. These attached socks resistance and are designed to be used over primary do not have adequate durability or slip resistance to be flame-resistant garments such as Nomex® IIIA. Users of worn as the outer foot covering. Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 2Respirator fit hoods are designed with a longer zipper, SFR garments should not knowingly enter an explosive ® extending to the chin for complete coverage of the neck environment. Consult the Tychem user manual, located area. Standard hoods only extend to the neck. on our website, for instructions on proper use, care and ® of protection Level See page 7 for photos. maintenance of your Tychem garments.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 43 DuPont™ Tychem® Responder® CSM Original name: Tychem® RESPONDER® CSM

Encapsulated Level A High-level protection against toxic and corrosive gaseous, liquid and RC550TTNXX000100 solid chemicals MD–4X RC550TTNXX00017C Used for military weapon call for sizing demilitarization RC550TTNXX00017S Suited for Hazmat and domestic call for sizing preparedness situations RC550TTNXX00017W Tychem® Responder® CSM is multiple call for sizing NAFTA/TAA COMPLIANT barrier films laminated to both sides of a strong substrate fabric Front entry Double taped seams Tychem® Responder® CSM provides at Three-layer visor system least 30 minutes of protection against (PVC 40 mil/Teflon™ 5 mil/ PVC 20 mil) >320 chemical challenges Gas-tight zipper closure ® ® Double storm flap with Tychem Responder CSM is tan for hook-and-loop closure Front discretionary purposes and features a ® Two exhaust valves entry low-visibility patch Expanded back Attached butyl gloves All Tychem® Responder® CSM (mil. spec. glove) suits are NAFTA/TAA compliant Attached socks1 Outer boot flaps RC550T

Coverall

RC128TTNXX000100 NAFTA/TAA COMPLIANT

Double taped seams Attached hood (respirator fit)2 Zipper closure Double storm flap with hook-and-loop closure Attached butyl gloves (mil. spec. glove) with attached conical cuff for jam fit Attached socks1 Outer boot flaps SM–4X

Please note that Tychem® fabrics have different Storm flaps: All taped seam coveralls have a double permeation performance. Please check SafeSPEC™ storm flap with a hook-and-loop closure. for permeation data that meets your specific needs. Seams and closures have less barrier than fabric. Stock/make to order designations are based on Note: Not all sizes available in all styles. sales volume and production efficiencies. Therefore, ® designations are subject to change without notice. Warning: Most Tychem garments should not be used around heat, flames, sparks or in potentially flammable 1 ® ® ® ® These Tychem Responder CSM garments have or explosive environments. Only Tychem® 6000 FR and Tychem Responder CSM attached socks made of the garment material. These Tychem® 10000 FR garments are designed and tested attached socks must be worn inside protective outer to help reduce injury during escape from a flash fire. footwear and are not suitable as outer footwear. These Tychem® 2000 SFR garments offer secondary flame attached socks do not have adequate durability or slip resistance and are designed to be used over primary resistance to be worn as the outer foot covering. flame-resistant garments such as Nomex® IIIA. Users of 2Respirator fit hoods are designed with a longer zipper, Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 extending to the chin for complete coverage of the neck SFR garments should not knowingly enter an explosive ®

area. Standard hoods only extend to the neck. environment. Consult the Tychem user manual, located of protection Level See page 7 for photos. on our website, for instructions on proper use, care and maintenance of your Tychem® garments.

44 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 10000 Original name: Tychem® TK

Encapsulated Level A Premium protection against toxic and corrosive gaseous, liquid and TK554TLYXX000100 solid chemicals MD–4X TK554TLYXX00015C Leading garment chosen by MD–4X Hazmat responders worldwide TK554TLYXX00017S Extremely durable, puncture- and call for sizing tear-resistant fabric NAFTA/TAA COMPLIANT Front Wide range of garment styles, Front entry entry including totally encapsulated, vapor Double taped seams protective Level A and liquid-splash EX (extra–wide) three-layer faceshield (PVC 40 mil/Teflon™ protective Level B suits 5 mil/PVC 20 mil) Gas-tight PVC zipper closure Tychem® 10000 provides at least Double storm flaps with 30 minutes of protection against hook-and-loop closure >320 chemical challenges Two exhaust valves Expanded back TK554T Tychem® TK612T/613T Internal adjustment belt certified to NFPA 1994 Class 2, Attached internal multi-layer laminate gloves Standard on Protective Ensembles Attached outer butyl or Viton™ gloves Encapsulated Level A— for First Responders to Hazardous Knee wear pads certified to NFPA 1994 Class 2 Materials Emergencies and CBRN Attached socks1 Terrorism Incidents Outer boot flaps with elastic TK612TLYXX000100 Front entry, MD–4X

Encapsulated Level A TK613TLYXX000100 Rear entry, call for sizing TK555TLYXX000100 NAFTA/TAA COMPLIANT Tychem® 10000 is lime yellow MD–4X Double taped seams for high visibility TK555TLYXX00015C EX (extra–wide) MD–4X three-layer faceshield All Tychem® 10000 encapsulated ™ (PVC 40 mil/Teflon suits are NAFTA/TAA compliant TK555TLYXX00017S 5 mil/PVC 20 mil) call for sizing Gas-tight zipper closure NAFTA/TAA COMPLIANT Double storm flap Rear Two exhaust valves Rear entry entry Expanded back Double taped seams Attached two-layer EX (extra–wide) three-layer gloves (multi-layer faceshield (PVC 40 mil/Teflon™ laminate/neoprene) TK612T TK613T 5 mil/PVC 20 mil) Attached socks1 Front entry Rear entry Gas-tight PVC zipper closure Outer boot flaps Double storm flaps with with elastic hook-and-loop closure Two exhaust valves not suitable as outer footwear. These attached socks Expanded back do not have adequate durability or slip resistance to be Internal adjustment belt worn as the outer foot covering. Attached internal multi-layer laminate gloves Storm flaps: All taped seam coveralls have a storm flap or double storm flap, see product description for details. Attached outer butyl or Viton™ gloves Knee wear pads Seams and closures have less barrier than fabric. Attached socks1 Note: Not all sizes available in all styles. Outer boot flaps with elastic Warning: Most Tychem® garments should not be used Tychem® 10000 around heat, flames, sparks or in potentially flammable or explosive environments. Only Tychem® 6000 FR and ® Please note that Tychem® fabrics have different Tychem 10000 FR garments are designed and tested permeation performance. Please check SafeSPEC™ to help reduce injury during escape from a flash fire. ® for permeation data that meets your specific needs. Tychem 2000 SFR garments offer secondary flame resistance and are designed to be used over primary Stock/make to order designations are based on flame-resistant garments such as Nomex® IIIA. Users of sales volume and production efficiencies. Therefore, Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 designations are subject to change without notice. SFR garments should not knowingly enter an explosive 1 ® ®

These Tychem 10000 garments have attached socks environment. Consult the Tychem user manual, located of protection Level made of the garment material. These attached socks on our website, for instructions on proper use, care and must be worn inside protective outer footwear and are maintenance of your Tychem® garments.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 45 DuPont™ Tychem® 10000 Original name: Tychem® TK

Encapsulated Level A Coverall

TK552TLYXX00017R TK128TLYXX000200 NAFTA/TAA COMPLIANT NAFTA/TAA COMPLIANT BERRY AMENDMENT COMPLIANT Taped seams Front entry Attached hood (respirator fit)2 Double taped seams Zipper closure Standard three-layer faceshield Double storm flaps with (PVC 40 mil/Teflon™ 5 mil/ tape closure Front PVC 20 mil) Elastic wrists entry Gas-tight PVC zipper closure Attached socks1 Double storm flap with Outer boot flaps with elastic hook-and-loop closure SM–6X Two exhaust valves Internal adjustable belt Flat back Attached butyl outer/multi-layer laminate internal gloves Attached socks1 Outer boot flaps with elastic LG–2X

Encapsulated Level B TK128T TK527TLYXX0001BN NAFTA/TAA COMPLIANT BERRY AMENDMENT COMPLIANT

Front entry Taped seams Standard faceshield (40 mil PVC) Zipper closure Double storm flaps with hook-and-loop closure Front Two exhaust vents entry Expanded back Elastic wrists Attached socks1 Outer boot flaps with elastic SM–4X

Please note that Tychem® fabrics have different Storm flaps: All taped seam coveralls have a storm flap permeation performance. Please check SafeSPEC™ or double storm flap, see product description for details. for permeation data that meets your specific needs. Seams and closures have less barrier than fabric. Stock/make to order designations are based on Note: Not all sizes available in all styles. sales volume and production efficiencies. Therefore, ® designations are subject to change without notice. Warning: Most Tychem garments should not be used around heat, flames, sparks or in potentially flammable 1 ® Tychem® 10000 These Tychem 10000 garments have attached socks or explosive environments. Only Tychem® 6000 FR and made of the garment material. These attached socks Tychem® 10000 FR garments are designed and tested must be worn inside protective outer footwear and are to help reduce injury during escape from a flash fire. not suitable as outer footwear. These attached socks Tychem® 2000 SFR garments offer secondary flame do not have adequate durability or slip resistance to be resistance and are designed to be used over primary worn as the outer foot covering. flame-resistant garments such as Nomex® IIIA. Users of 2Respirator fit hoods are designed with a longer zipper, Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 extending to the chin for complete coverage of the neck SFR garments should not knowingly enter an explosive area. Standard hoods only extend to the neck. environment. Consult the Tychem® user manual, located See page 7 for photos. on our website, for instructions on proper use, care and ® of protection Level maintenance of your Tychem garments.

46 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® 10000 FR Original name: Tychem® Reflector®

Fully encapsulated Level A “Single skin” garment offers broad Tychem® 10000 FR— chemical holdout certified to NFPA 1991 Ideally suited for industrial and RF600TSVXX000100 Hazmat situations

RF600TSVXX00017M Chemical protection in one garment RF600TSVXX00017N that is easy to don and doff NAFTA/TAA COMPLIANT Tychem® 10000 FR provides at least Front entry 30 minutes of protection against Double taped seams >290 chemical challenges Three-layer Front entry ™ (PVC 40 mil/Teflon 5 mil/ Certified to NFPA 1991, Standard PVC 40 mil) faceshield Gas-tight zipper closure on Vapor-Protective Ensembles for Double storm flaps with Hazardous Materials Emergencies and hook-and-loop closure CBRN Terrorism Incidents, with flash fire Two Pirelli® exhaust valves escape and liquefied gas options Expanded back Glove liners Multi-layer attached gloves (multi-layer laminate/neoprene/ ® knit) ® 1 Tychem 10000 FR is high-visibility silver Attached socks RF600T Outer boot flaps ® SM–4X All Tychem 10000 FR suits are NAFTA/TAA compliant

Please note that Tychem® fabrics have different Warning: Suits do not provide thermal skin protection permeation performance. Please check SafeSPEC™ for direct contact with hot solids or liquids. They do not for permeation data that meets your specific needs. provide protection from continuous radiant heat sources ® Tychem® 10000 FR Stock/make to order designations are based on such as furnaces or smelters. Most Tychem garments sales volume and production efficiencies. Therefore, should not be used around heat, flames, sparks or in designations are subject to change without notice. potentially flammable or explosive environments. Only Tychem® 6000 FR and Tychem® 10000 FR garments are 1 ® These Tychem 10000 FR garments have attached socks designed and tested to help reduce injury during escape made of the garment material. These attached socks from a flash fire. Tychem® 2000 SFR garments offer must be worn inside protective outer footwear and are secondary flame resistance and are designed to be used not suitable as outer footwear. These attached socks over primary flame resistant garments such as Nomex® do not have adequate durability or slip resistance to be IIIA. Users of Tychem® 6000 FR, Tychem® 10000 FR and worn as the outer foot covering. Tychem® 2000 SFR garments should not knowingly enter Seams and closures have less barrier than fabric. an explosive environment. Consult the Tychem® user

manual, located on our website, for instructions of protection Level on proper use, care and maintenance of your Tychem® garments.

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 47 DuPont™ Tychem® accessories

Tychem® 10000 fully encapsulated training suit TK586SLYXX000100 Front entry, MD–4X TK586SLYXX00017W Front entry, MD–4X TK586TLYXX000100 Front entry, MD–6X Cool-Guard® vest Glove ring assembly— TK587SLYXX000100 996000BU00000100 Male glove insert Rear entry, MD–4X Personal cooling product 99961000000002DL NAFTA/TAA COMPLIANT Cool-Guard® refills EX (extra-wide) faceshield (20 mil PVC) 9960300000000100 Spare set of 4 Zipper closure Storm flap over zipper Internal waist belt Expanded back Attached butyl gloves Attached socks1 Outer boot flaps Clearly labeled as a training suit

Universal pressure test kit 99081000000001UV

The universal pressure test kit is designed for periodic air pressure testing on all Pirelli® air relief exhaust valve Auer® air relief exhaust valve Level A fully encapsulated suits. 9993700000000100 9902600000000100 This compact, lightweight kit is completely self-contained, requiring no external air supply.

Input voltage 85–264 vac @ 47–63 Hz or 120–370 vdc

Additional components available, please call customer service. Pirelli® exhaust diaphragm For a complete list of pass-thru option codes, please see page 9. Auer® adapters for test kits 9912200000000100 1/cs For more detailed information regarding pass-thrus, please call 9912200000000200 2/cs 9911600000000100 Customer Service. 9912200000000300 3/cs Two adapters for DuPont kit to test 1These Tychem® garments have attached socks made ® ® Tychem Responder CSM suits of the garment material. These attached socks must be worn inside protective outer footwear and are not suitable as outer footwear. These attached socks do not have adequate durability or slip resistance to be worn as the outer foot covering. Warning: Most Tychem® garments should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Only Tychem® 6000 FR and Tychem® 10000 Pirelli® adapters for test kits FR garments are designed and tested to help reduce injury during escape from a flash fire. Tychem® 2000 SFR garments 9993900000000100 offer secondary flame resistance and are designed to be used Two adapters for DuPont kit to test over primary flame resistant garments such as Nomex® IIIA. Tychem® Responder® CSM suits Users of Tychem® 6000 FR, Tychem® 10000 FR and Tychem® 2000 SFR garments should not knowingly enter an explosive environment. Consult the Tychem® user manual, located on our website, for instructions on proper use, care and maintenance of your Tychem® garments. 48 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com Sizing charts Sizing for protective garments

7'6˝ 229 cm

7'4˝ 224 cm

7'2˝ 218 cm 7X

7'0˝ 213 cm 6X 6'10˝ 208 cm 5X 6'8˝ 203 cm

6'6˝ 198 cm 4X 6'4˝ 193 cm 3X 6'2˝

Height 2X 188 cm

6'0˝ 183 cm XL 5'10˝ 178 cm

5'8˝ 173 cm LG 5'6˝ 168 cm 5'4˝ MD 163 cm SM 5'2˝ 157 cm

5'0˝ 152 cm 90 lb 110 lb 130 lb 150 lb 170 lb 190 lb 210 lb 230 lb 250 lb 270 lb 290 lb 310 lb 330 lb 350 lb 370 lb 390 lb 41 kg 50 kg 59 kg 68 kg 77 kg 86 kg 95 kg 104 kg 113 kg 122 kg 132 kg 141 kg 150 kg 159 kg 168 kg 177 kg Weight

Sizing for fully encapsulated suits This chart is based on individuals wearing SCBA, safety and standard work clothing. Fit varies with individual body shape. 6'8˝ 203 cm

6'6˝ 198 cm

6'4˝ 193 cm

6'2˝ 4X 188 cm 2X and 3X 6'0˝ 183 cm

5'10˝ 178 cm

Height 5'8˝ 173 cm LG and XL 5'6˝ 168 cm 5'4˝ SM and MD 163 cm

5'2˝ 157 cm

5'0˝ 152 cm 90 lb 110 lb 130 lb 150 lb 170 lb 190 lb 210 lb 230 lb 250 lb 270 lb 290 lb 310 lb 330 lb 350 lb 370 lb 390 lb 41 kg 50 kg 59 kg 68 kg 77 kg 86 kg 95 kg 104 kg 113 kg 122 kg 132 kg 141 kg 150 kg 159 kg 168 kg 177 kg Weight

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 49 DuPont™ Tychem® gloves

Tychem® PV350 Tychem® NT450 Extremely durable, -lined PVC Flexible knit-lined dual nitrile glove. construction with rough grip. Suitable for Protects against an array of solvents, oils defensive protection from chemicals, oils and acids. and greases. NT4500BU080144KL PV3500BK100144CF NT4500BU090144KL NT4500BU100144KL CAT III, EN ISO 374-1, Type B, NT4500BU110144KL EN ISO 374-5, EN 388 Fully coated PVC, CAT III, EN ISO 374-1, Type A, cotton/jersey EN ISO 374-5, EN 388 Thickness: 55 mil (1.40 mm) Double coated full nitrile, Nominal coating thickness: cotton/ 20 mil (0.51 mm) Thickness: 56 mil (1.42 mm) Length: 14 in. (356 mm) Nominal coating thickness: 10/LG 13 mil (0.33 mm) Length: 14 in. (356 mm) 8/S–11/XL

Tychem® NT420 Tychem® NT470 Chemical splash and oil protection. Resistant to a range of solvents, oils, Designed for jobs requiring barrier hydrocarbons, animal fats, greases and protection, while keeping tactile other chemicals. Bisque finish allows secure discrimination. handling in wet and dry conditions. Unlined, with an ergonomic design to maximize comfort. NT4200BU061000UL NT4200BU071000UL NT4200BU081000UL NT4700GR060288UL NT4200BU091000UL NT4700GR070288UL NT4700GR080288UL CAT III, EN ISO 374-1, NT4700GR090288UL Type B, EN ISO 374-5 NT4700GR100288UL 100% nitrile, unlined NT4700GR110288UL Thickness: 8 mil (0.2 mm) Length: 9.5 in. (240 mm) CAT III, EN ISO 374-1, Type A, EN ISO 374-5, EN 388 6/S–9/XL 100% nitrile, unlined Thickness: 15 mil (0.38 mm) Length: 13 in. (330 mm) 6/XS–11/XXL Tychem® NT430 Lightweight with “second-skin“ feel. Resistant to oils, hydrocarbons and greases. Tychem® NT480 Lint-free, dust-free cuff prevents dirt from entering the glove. Bisque finish allows secure handling in wet and dry conditions. Resistant to a range of solvents, animal fats and other chemicals. NT4300BU060288UL Flock-lined with an ergonomic design for NT4300BU070288UL enhanced comfort. NT4300BU080288UL NT4300BU090288UL NT4800GR060288CF NT4300BU100288UL NT4800GR070288CF NT4300BU110288UL NT4800GR080288CF CAT III, EN ISO 374-1, Type A, NT4800GR090288CF EN ISO 374-5 NT4800GR100288CF 100% nitrile, unlined NT4800GR110288CF Thickness: 9 mil (0.23 mm) CAT III, EN ISO 374-1, Type A, Length: 12 in. (305 mm) EN ISO 374-5, EN 388 6/XS–11/XXL 100% nitrile, cotton flock Thickness: 15 mil (0.38 mm) Length: 13 in. (330 mm) 6/XS–11/XXL

50 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont™ Tychem® gloves

Tychem® NP530 Tychem® BT730 Tychem® VB870 Double-dipped neoprene over natural Protection against a wide array of Provides protection from a variety of rubber for dexterity. Resistant to a wide chemicals. Provides resistance to many chlorinated solvents and aliphatic or range of chemicals. highly corrosive acids and is designed for aromatic hydrocarbons, such as benzene, handling ketones and alcohols. toluene and xylene. Suitable for military applications. NP5300BK070288CF NP5300BK080288CF BT7300BK070024UL NP5300BK090288CF BT7300BK080024UL VB8700BK090024UL NP5300BK100288CF BT7300BK090024UL VB8700BK100024UL BT7300BK100024UL VB8700BK110024UL CAT III, EN ISO 374-1, Type A, BT7300BK110024UL EN ISO 374-5, EN 388 CAT III, EN ISO 374-1, Type A, Neoprene over natural rubber, CAT III, EN ISO 374-1, Type A, EN ISO 374-5, EN 388 cotton flock EN ISO 374-5, EN 388 Fully coated Viton™ Thickness: 26 mil (0.66 mm) Fully coated butyl, unlined over butyl, unlined Length: 12 in. (305 mm) Thickness: 14 mil (0.35 mm) Thickness: 28 mil (0.71 mm) 7/S–10/XL Length: 14 in. (356 mm) Length: 14 in. (356 mm) 7/S–11/XXL 9/L–11/XXL

Tychem® NP560 Tychem® BT770 Resistant to a wide range of chemicals, Provides protection against a variety including acids, caustics, solvents, greases of highly corrosive chemicals, alcohols, and oils. Suitable for heavy-duty work or ketones and esters. applications involving exposure to the presence of solvents. BT7700BK080024UL BT7700BK090024UL NP5600BK080144KL BT7700BK100024UL NP5600BK090144KL BT7700BK110024UL NP5600BK100144KL NP5600BK110144KL CAT III, EN ISO 374-1, Type A, EN ISO 374-5, EN 388 CAT III, EN ISO 374-1, Type A, Fully coated butyl, unlined EN ISO 374-5, EN 388 Thickness: 28 mil (0.7 mm) Fully coated flexible neoprene, 15-gauge seamless, Length: 14 in. (356 mm) polyester knit liner 8/M–11/XXL Thickness: 55 mil (1.39 mm) Nominal coating thickness: 30 mil (0.76 mm) Length: 14 in. (356 mm) Tychem® VB830 8/S–11/XL Provides protection from a variety of chlorinated solvents and aliphatic or aromatic hydrocarbons, such as benzene, toluene and xylene. Tychem® NP570 CT Protection against the dual risk of chemical VB8300BK070024UL exposure and cut. Provides ANSI level A5 VB8300BK080024UL and EN level 5 cut protection, as well as first-class defense against acids, caustics, VB8300BK090024UL solvents, greases and oils. VB8300BK100024UL VB8300BK110024UL NP5700BK080144EY NP5700BK090144EY CAT III, EN ISO 374-1, Type A, EN ISO 374-5, EN 388 NP5700BK100144EY Fully coated Viton™ NP5700BK110144EY over butyl, unlined CAT III, EN ISO 374-1, Type A, Thickness: 12 mil (0.30 mm) EN ISO 374-5, EN 388, Length: 12 in. (305 mm) ANSI CUT A5 7/S–11/XXL Neoprene, 13-gauge engineered yarn Thickness: 68 mil (1.73 mm) Nominal coating thickness: 30 mil (0.76 mm) Length: 14 in. (356 mm) 8/S–11/XL

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 51 DuPont Controlled Environments

DuPont sterile cleanroom garments, designed for single use, offer meaningful advantages in today’s challenging cleanroom environments. DuPont materials provide a welcome range of comfort, durability, breathability and protection in a variety of styles, including coveralls, lab coats, gowns, hoods and footwear covers.

DuPont quality systems for cleanroom garments DuPont single-use garments for controlled environments offer the following standards of quality:

• The DuPont Controlled Environments quality management system is ISO 9001:2015 registered • DuPont ™ Tyvek® IsoClean® sterile garments have a sterility assurance level of 10-6. Irradiation doses are validated in accordance with ANSI/AAMI/ISO 11137 through bioburden and dose verification testing • Tyvek ® IsoClean® sterile garments are gamma irradiated in a facility that is registered by ISO 13485 quality standard and adheres to the requirements of ANSI/AAMI/ISO 11137 • A Certificate of Sterility and a Certificate of Compliance come with every shipment of sterile Tyvek® IsoClean® single-use garments • Dose audits are conducted quarterly to maintain dose validation • Customers are invited to audit our manufacturing and sterilization facilities • Quality documentation is readily available on request to help meet customer requirements • Lot traceability is maintained through garment manufacturing, processing and sterilization

The superiority of single-use garments from DuPont DuPont single-use garments offer the following advantages: Among the most popular products in the DuPont Controlled Environments Quality portfolio, Tyvek® IsoClean® clean-processed and sterile single-use garments Single-use garments are not subjected to multiple cycles offer an ideal balance of protection, durability and comfort. In addition, of wearing, laundering and sterilization, so fabric barrier they feature the lowest linting and particle shedding of any garments in the DuPont portfolio. and strength are consistent and predictable. Also, DuPont Controlled Environments garments help minimize cross- Options contamination risk because clean-processing and packaging CS Clean and sterile: clean-processed, individually are done in a facility that only handles new garments. packaged and sterilized by gamma irradiation

Flexibility 0S Sterile: individually packaged and sterilized by The DuPont single-use apparel program allows you to order gamma irradiation only the quantities that you plan to use, which offers flexibility as your needs change. 0C Clean: clean-processed, individually packaged

Cost control 00 or 0B Bulk packaged Single-use garments help eliminate budget uncertainties PI Individually packaged in an opaque bag associated with garment repair, damage and loss, helping you to better predict expenditures. BB Bulk packaged BH 50/bag MP Multipack

52 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com Controlled environments apparel selection guide

DuPont Controlled Environments garments: Tyvek® IsoClean®, Tyvek® Micro-Clean® 2-1-2, ProClean® 6

Tyvek® Tyvek® IsoClean® ProClean® 6* Micro-Clean® 2-1-2 Considerations Clean- Clean- Bulk processed Sterile processed Sterile Non-sterile** Non-sterile non-sterile sterile non-sterile Environments

ISO Class 5 Tyvek® IsoClean® sterile Aseptic Cleanrooms garments offer excellent (Former FED-STD- + cleanliness, barrier and sterility 209E; Class 100) assurance level.

ISO Class 6, 7 and 8 Tyvek® IsoClean® sterile Bioburden Control Areas garments offer excellent (Former FED-STD- + + cleanliness, barrier and sterility 209E; Class 1000, assurance level. 10,000 and 100,000)

ISO Class 6, 7 and 8 Tyvek® is durable, low-linting Cleanrooms (Former and provides an inherent FED-STD-209E; Class 1000, particle barrier. Clean processing 10,000 and 100,000) + + and bound seams should be considered for more critical environments.

Hazards

Non-hazardous Tyvek® provides an inherent dry particles * barrier against small particles. + + + + + + + Bound seam garments offer a higher level of protection than serged seam garments.

Non-hazardous, * ProClean® provides an effective light liquid splash + barrier against a variety of common non-hazardous liquids.

Hazardous powders Use bound seam garments when Notice: DuPont Controlled working with hazardous powders. Environments garments should not be used in + + + + potentially explosive or flammable environments.

Hazardous liquid splash Please refer to our Tychem® Examples: organic product line for liquid and vapor solvents, caustics chemical protection.

Electric arc, Please refer to Nomex® for flame- industrial fire hazard, resistant apparel. Controlled welding environment garments are not suitable for activities, Do Not Use nor for protection from hot liquids, steam, molten metals, welding, electric arc or thermal radiation.

Comparison within the DuPont portfolio: * Barrier properties may be compromised through use. ** Packaged individually. + Best

Better

(Blank) Not recommended

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 53 DuPont Controlled Environments

NOTE Please substitute your size for XX when ordering. See page 8 for full part number description.

Coverall Boot cover

IC253BWHXX00250B IC447SWHXX01000B SM–5X SM–XL IC253BWHXX00250S IC447SWHXX01000C SM–5X MD–XL IC253BWHXX00250C IC447SWHXX0100CS SM–5X MD–2X IC253BWHXX0025CS Serged seams SM–7X Elastic openings Bound seams Elastic ankles Bound neck Gripper™ sole Dolman sleeve 18˝ high Zipper closure 100/cs (50 pairs) Elastic wrists Elastic ankles 25/cs Boot cover Coverall IC458BWHXX01000B MD–XL IC105SWHXX002500 IC458BWHXX01000C MD–3X MD–XL IC105SWHXX00250C IC458BWHXX0100CS MD–3X SM–XL Tyvek® IsoClean® IC105SWHXX0025CS Bound seams MD–4X Elastic openings Made from Tyvek® brand flashspun Serged seams Ties at ankles polyolefin protective material Standard hood Gripper™ sole Elastic hood opening 18˝ high Unique, patented flash-spinning Set sleeve 100/cs (50 pairs) Zipper closure process creates a barrier to dry Elastic wrists particles, microorganisms and Elastic ankles non-hazardous liquids Attached thumb loops Boot cover Comfortable, lightweight and durable Attached boots with PVC soles IC457SWHXX01000B 25/cs IC457SWHXX01000S Garments available gamma sterilized to an SAL of 10–6 Coverall Serged seams IC254BWHXX0025CS Elastic openings Serged or bound seams with covered Ties at ankles elastic options Bound seams PVC sole Bound neck 18˝ high Bound seam garments offer highest Dolman sleeve 100/cs (50 pairs) particle barrier within DuPont CE Zipper closure SM–XL product portfolio Snaps for aseptic donning Elastic wrists Traceability on all sterilized apparel Elastic ankles ™ 25/cs Gripper soles offer a higher level Shoe cover SM–4X of slip resistance than standard IC461SWHXX03000B PVC soles Coverall ® ® Serged seams Tyvek IsoClean is white IC181SWHXX002500 SM–8X Elastic openings PVC sole IC181SWHXX00250C Elastic toe SM–4X 5˝ high Serged seams 300/cs (150 pairs) Standard collar SM–XL Note: All sizes not available in all styles. For one size fits Set sleeve most use 00 in the part number. Zipper closure Seams and closures have less barrier than fabric. Elastic wrists Elastic ankles 25/cs 54 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com DuPont Controlled Environments

NOTE Please substitute your size for XX when ordering. See page 8 for full part number description.

Frock—Tyvek® IsoClean® Shoe cover—Tyvek® IsoClean®

IC270BWHXX003000 IC451BWHXX01000B

IC270BWHXX00300C Serged seams IC270BWHXX0030CS Elastic openings Gripper™ sole Bound seams 5" high Bound neck 100/cs (50 pairs) Set sleeve MD–XL Snap closure (6 + 1 adjustable) Elastic wrists SM–4X

Lab coat—Tyvek® IsoClean®

Frock—Tyvek® IsoClean® IC224SWHXX00300B

IC264SWHXX00300B Serged seams Laydown collar IC264SWHXX00300C Raglan sleeve IC264SWHXX0030CS Snap closure (5) Pockets Serged seams (1 left chest pencil, 2 lower front) Bound neck SM–2X Raglan sleeve Zipper closure Elastic wrists A-line SM–4X Coverall—Tyvek® IsoClean®

IC182BWHXX002500 IC182BWHXX00250C Frock—Tyvek® IsoClean® IC182BWHXX0025CS IC263SWHXX00300B Bound seams Serged seams Bound neck High mandarin collar w/snap Raglan sleeve Set sleeve Zipper closure Snap closure (6) Elastic wrists Elastic wrists Elastic ankles SM–4X SM–4X

Hood—Tyvek® IsoClean® Hood/mask—Tyvek® IsoClean®

IC668BWHXX01000B IC669BWHXX01000S

IC668BWHXX01000C Integrated hood/ IC668BWHXX0100CS mask combination Bound seams Bound seams Bound head opening Full face opening Ties with loops for fit Bound hood opening White hood Ties with loops for fit Blue face mask One size fits most Pleated polyethylene outer 7” wide mask Individually packaged 100/cs One size fits most

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 55 DuPont Controlled Environments

NOTE Please substitute your size for XX when ordering. See page 8 for full part number description.

Shoe cover—ProShield® 30 Shoe cover—ProShield® 30

PE440SBUXX020000 PE440SWHXX020000

Serged seams Serged seams Elastic openings Elastic openings 5.5" height 5.5" height 200/cs (100 pairs) 200/cs (100 pairs) LG–XL MD–XL

Controlled environment mask— Boot cover—ProShield® 30 DuPont™ Sierra™ PE444SWHXX010000 ML7360WHXX0250BH Serged seams ML7360WHXX02500S Elastic openings Elastic ankles 9˝ size 13" height Bound Tyvek® ties 100/cs (50 pairs) Pleated LG–XL outer facing Metal nose piece One size fits most

Sleeves Coverall— Tyvek® Micro-Clean® 2-1-2 IC501BWHXX01000B CC252BBUXX00250S IC501BWHXX01000C SM–5X CC252BBUXX0025PI IC501BWHXX01000S SM–5X IC501BWHXX0100CS Bound seams Bound neck with loop Bound seams at center back Elastic openings Dolman sleeve 18˝ length Zipper closure One size fits most Elastic wrists Elastic ankles

Made from Tyvek® brand flashspun polyolefin protective material

Coated on both sides with proprietary 2-1-2 blue polymeric resin

Antistatic treated

Garments available gamma sterilized to an SAL of 10-6

Traceability on all sterilized apparel

56 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com Tyvek ® protective apparel recycling program

Tyvek® is proud to offer a garment recycling program that helps our customers within the continental manage used Tyvek® and IsoClean® protective apparel and reduce waste. The program includes setup, collection, transportation, storage and recycling of garments.

Why recycle? The Tyvek® protective apparel recycling program offers the chance to divert garments away from landfills and give them a second life in products like , lumber and park benches. Conserve materials and energy

Predicted savings For every case of 25 Tyvek® coveralls that is recycled, 10 lbs. of Tyvek® are diverted from the waste stream and given a second life in products like pallets and park benches. DuPont offers this service for free to qualifying customers. On an annualized usage basis, the savings really add up. Lower waste-related costs

Recycling process

Increase eligibility for grants and incentives

Boost employee morale DuPont sustainability Sustainability is at the core of what we do—from reducing our operational footprint and creating market-facing sustainable solutions to addressing the global challenges of the future. This program is yet another example of the DuPont commitment to sustainability. The Tyvek® protective apparel recycling Meet your ISO 14001 goals program is easy to participate in and is a cost-effective and responsible choice.

For more information, call 1 800 931 3456 or contact your local DuPont sales representative. personalprotection.dupont.com Help the environment

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 57 Notes

58 Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com Notes

Customer service 1 800 931 3456 safespec.dupont.com personalprotection.dupont.com 59 The product information contained is current as of the date of publication, but may be 7) The outer glove on Tychem® 10000 FR suits may contain natural rubber latex which revised as new information is developed. Before relying on any performance data for the may cause allergic reactions in some sensitized individuals. Additionally, some internal purchase or performance of products, you should check safespec.dupont.com or contact components not expected to contact the wearer during use may contain natural Customer Service at 1 800 931 3456 to determine whether there is new information that rubber latex which may cause allergic reactions in some sensitized individuals. Anyone relates to your intended use or application of the product. who begins to exhibit an allergic response during the use of DuPont products should For more information, contact us at 1 800 931 3456. We also offer a 24-hour emergency immediately cease using these products. The incident should also be reported to DuPont hotline, 1 800 441 7515. at 1 800 441 3637 so that an investigation can be initiated. ® ® ® It is the responsibility of the user to: 8) Tyvek 500, Tyvek 600 and Tyvek 800 contain natural rubber latex which may cause Get trained in the proper use, handling, storage, maintenance and disposal of garments; allergic reactions in some sensitized individuals. Anyone who begins to exhibit an allergic response during the use of DuPont products should immediately cease using Review and understand available information about the appropriate use of garments/ these products. The incident should also be reported to DuPont at 1 800 441 3637 so that accessories; an investigation can be initiated. Verify that the garment is appropriate for the user’s specific application; 9) Tyvek ® coveralls and ProShield® 60 coveralls can be considered for use with the Verify that the garment meets all specified government and industry standards for user’s appropriate respirators and other suitable PPE to minimize contact with isocyanate paint specific application; aerosols. Tyvek® garments are not appropriate if they are getting wet (paint is dripping or running, or wet to the touch) or if spotting is observed on skin or garments worn under Carefully inspect the garment for damage before and after use, including all fabric, seams the coveralls. Tychem® aprons and smocks are available for situations where prolonged and closures. liquid exposure may be limited to the front of the torso and/or arms of the wearer. Warnings: These aprons and smocks can be worn with Tyvek® to provide localized protection while 1) Tyvek ® and ProShield® garments should not be used around heat, flame, sparks or in limiting the level of thermal discomfort. potentially flammable or explosive environments. ProShield® 6 SFR garments offer secondary flame resistance and are to be worn over primary flame-resistant garments This information is based upon technical data that DuPont believes to be reliable. It is such as Nomex® IIIA. subject to revision as additional knowledge and experience are gained. DuPont makes 2) Most Tychem® garments should not be used around heat, flames, sparks or in potentially no guarantee of results and assumes no obligations or liability in connection with this flammable or explosive environments. Only Tychem® 6000 FR and Tychem® 10000 FR information. It is the user’s responsibility to determine the level of toxicity and the proper garments are designed and tested to help reduce injury during escape from a flash fire. personal protective equipment needed. The information set forth herein reflects laboratory Tychem® 2000 SFR garments offer secondary flame resistance and are designed to be performance of fabrics, not complete garments, under controlled conditions. It is intended used over primary flame-resistant garments such as Nomex® IIIA. Users of Tychem® 6000 for information use by persons having technical skill for evaluation under their specific end- FR, Tychem® 10000 FR and Tychem® 2000 SFR garments should not knowingly enter an use conditions, at their own discretion and risk. explosive environment. Consult the Tychem® user manual, located on our website, for Anyone intending to use this information should first verify that the garment selected instructions on proper use, care and maintenance of your Tychem® garments. is suitable for the intended use. In many cases, seams and closures have shorter 3) Garments should have slip-resistant or antislip materials on the outer surface of boots, breakthrough times and higher permeation rates than the fabric. If fabric becomes torn, shoe covers or other garment surfaces in conditions where slipping could occur. abraded or punctured, end user should discontinue use of garment to avoid compromising 4) Some Tychem® garments have attached socks made of the garment material. These the barrier protection. SINCE CONDITIONS OF USE ARE OUTSIDE OUR CONTROL, WE attached socks must be worn inside protective outer footwear and are not suitable as MAKE NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, NO outer footwear. These attached socks do not have adequate durability or slip resistance WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE AND ASSUME to be worn as the outer foot covering. NO LIABILITY IN CONNECTION WITH ANY USE OF THIS INFORMATION. This information is not intended as a license to operate under or a recommendation to infringe any patent, 5) If fabric becomes torn, scratched or punctured, or if a garment closure or seam fails, trademark or technical information of DuPont or others covering any material or its use. user should immediately discontinue use of garment to avoid serious injury, including potentially deadly chemical exposure(s). Seams, closures and visors may provide less Any warranty for products offered in this catalog can be found in the Terms and Conditions protection than fabric. for that product. 6) Serged and/or bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present.

DuPont™ SafeSPEC™—we’re here to help Certified Industrial Hygienist team Our powerful web-based tool can assist you with A DuPont Certified Industrial Hygienist can conduct a job finding the appropriate DuPont garments for chemical, hazard assessment to help you determine the best DuPont controlled environment, thermal and mechanical hazards. garment for a specific hazard. safespec.dupont.com

DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with TM, SM or ® are owned by affiliates of DuPont de Nemours, Inc. unless otherwise noted. © 2019 DuPont. K-21025-8 (09/19)

DuPont Personal Protection Auer® is a trademark of MSA. Barrier® is a registered trademark of Follow DuPont Personal Protection Ansell. Best® is a registered trademark of Showa-Best Glove, Inc. Customer service 1 800 931 3456 Guardian™ is a trademark of Guardian Manufacturing. Lexan® is a safespec.dupont.com @DuPontPPE registered trademark of Saudi Basic Industries Corporation or its affiliates. Pirelli® is a registered trademark of Pirelli & C. S.p.A. personalprotection.dupont.com ® ™ DuPont Personal Protection Scott is a registered trademark of Scott Health & Safety. Teflon controlledenvironments.dupont.com and Viton™ are trademarks of The Company FC, LLC.