Microwave Measurements, 3Rd Edition

Total Page:16

File Type:pdf, Size:1020Kb

Microwave Measurements, 3Rd Edition IET ELECTRICAL MEASUREMENT SERIES 12 Microwave Measurements 3rd Edition Other volumes in this series: Volume 4 The current comparator W.J.M. Moore and P.N. Miljanic Volume 5 Principles ofmicrowave measurements G.H. Bryant Volume 7 Radio frequency and microwave power measurement A.E. Fantom Volume 8 A handbook for EMC testing and measurement D. Morgan Volume 9 Microwave circuit theory and foundations of microwave metrology G. Engen Volume 11 Digital and analogue instrumentation: testing and measurement N. Kularatna Microwave Measurements 3rd Edition Edited by R.J. Collier and A.D. Skinner The Institution of Engineering and Technology Published by The Institution of Engineering and Technology, London, United Kingdom © 1985, 1989 Peter Peregrinus Ltd © 2007The Institution of Engineering and Technology First published 1985 (0 86341 048 0) Second edition 1989 (0 86341 184 3) Third edition 2007 (978 0 86341 735 1) This publication is copyright under the Berne Convention and the Universal Copyright Convention. All rights reserved. Apart from any fair dealing for the purposes of research or private study, or criticism or review, as permitted under the Copyright, Designs and Patents Act, 1988, this publication may be reproduced, stored or transmitted, in any form or by any means, only with the prior permission in writing of the publishers, or in the case of reprographic reproduction in accordance with the terms of licences issued by the Copyright Licensing Agency. Inquiries concerning reproduction outside those terms should be sent to the publishers at the undermentioned address: The Institution of Engineering and Technology Michael Faraday House Six Hills Way, Stevenage Herts, SG1 2AY, United Kingdom www.theiet.org While the authors and the publishers believe that the information and guidance given in this work are correct, all parties must rely upon their own skill and judgement when making use of them. Neither the authors nor the publishers assume any liability to anyone for any loss or damage caused by any error or omission in the work, whether such error or omission is the result of negligence or any other cause. Any and all such liability is disclaimed. The moral rights of the author to be identified as author of this work have been asserted by him in accordance with the Copyright, Designs and Patents Act 1988. British Library Cataloguing in Publication Data Microwave measurements. – 3rd ed. 1. Microwave measurements I. Collier, Richard II. Skinner, Douglas III. Institution of Engineering and Technology 621.3’813 ISBN 978-0-86341-735-1 Typeset in India by Newgen Imaging Systems (P) Ltd, Chennai Printed in the UK by Athenaeum Press Ltd, Gateshead, Tyne & Wear Contents List of contributors xvii Preface xix 1 Transmission lines – basic principles 1 R. J. Collier 1.1 Introduction 1 1.2 Lossless two-conductor transmission lines – equivalent circuit and velocity of propagation 1 1.2.1 Characteristic impedance 4 1.2.2 Reflection coefficient 5 1.2.3 Phase velocity and phase constant for sinusoidal waves 5 1.2.4 Power flow for sinusoidal waves 6 1.2.5 Standing waves resulting from sinusoidal waves 7 1.3 Two-conductor transmission lines with losses – equivalent circuit and low-loss approximation 8 1.3.1 Pulses on transmission lines with losses 9 1.3.2 Sinusoidal waves on transmission lines with losses 10 1.4 Lossless waveguides 10 1.4.1 Plane (or transverse) electromagnetic waves 10 1.4.2 Rectangular metallic waveguides 12 1.4.3 The cut-off condition 14 1.4.4 The phase velocity 15 1.4.5 The wave impedance 15 1.4.6 The group velocity 16 1.4.7 General solution 16 Further reading 17 2 Scattering parameters and circuit analysis 19 P. R. Young 2.1 Introduction 19 2.2 One-port devices 19 vi Contents 2.3 Generalised scattering parameters 22 2.4 Impedance and admittance parameters 24 2.4.1 Examples of S-parameter matrices 27 2.5 Cascade parameters 27 2.6 Renormalisation of S-parameters 28 2.7 De-embedding of S-parameters 29 2.8 Characteristic impedance 30 2.8.1 Characteristic impedance in real transmission lines 30 2.8.2 Characteristic impedance in non-TEM waveguides 33 2.8.3 Measurement of Z0 35 2.9 Signal flow graphs 36 Appendices 37 2.A Reciprocity 37 2.B Losslessness 39 2.C Two-port transforms 40 References 41 Further reading 41 3 Uncertainty and confidence in measurements 43 John Hurll 3.1 Introduction 43 3.2 Sources of uncertainty in RF and microwave measurements 52 3.2.1 RF mismatch errors and uncertainty 52 3.2.2 Directivity 54 3.2.3 Test port match 54 3.2.4 RF connector repeatability 54 3.2.5 Example – calibration of a coaxial power sensor at a frequency of 18 GHz 54 References 56 4 Using coaxial connectors in measurement 59 Doug Skinner 4.1 Introduction 59 4.1.1 Coaxial line sizes 60 4.2 Connector repeatability 61 4.2.1 Handling of airlines 61 4.2.2 Assessment of connector repeatability 61 4.3 Coaxial connector specifications 62 4.4 Interface dimensions and gauging 62 4.4.1 Gauging connectors 62 4.5 Connector cleaning 63 4.5.1 Cleaning procedure 64 4.5.2 Cleaning connectors on static sensitive devices 64 4.6 Connector life 65 Contents vii 4.7 Adaptors 65 4.8 Connector recession 65 4.9 Conclusions 66 4.A Appendix A 66 4.B Appendix B 66 4.C Appendix C 85 4.D Appendix D 86 4.E Appendix E 87 Further reading 88 5 Attenuation measurement 91 Alan Coster 5.1 Introduction 91 5.2 Basic principles 91 5.3 Measurement systems 93 5.3.1 Power ratio method 94 5.3.2 Voltage ratio method 97 5.3.3 The inductive voltage divider 98 5.3.4 AF substitution method 104 5.3.5 IF substitution method 105 5.3.6 RF substitution method 107 5.3.7 The automatic network analyser 108 5.4 Important considerations when making attenuation measurements 110 5.4.1 Mismatch uncertainty 110 5.4.2 RF leakage 112 5.4.3 Detector linearity 112 5.4.4 Detector linearity measurement uncertainty budget 114 5.4.5 System resolution 115 5.4.6 System noise 115 5.4.7 Stability and drift 115 5.4.8 Repeatability 115 5.4.9 Calibration standard 116 5.5 A worked example of a 30 dB attenuation measurement 116 5.5.1 Contributions to measurement uncertainty 117 References 119 Further reading 120 6 RF voltage measurement 121 Paul C. A. Roberts 6.1 Introduction 121 6.2 RF voltage measuring instruments 122 6.2.1 Wideband AC voltmeters 122 6.2.2 Fast sampling and digitising DMMs 124 viii Contents 6.2.3 RF millivoltmeters 125 6.2.4 Sampling RF voltmeters 126 6.2.5 Oscilloscopes 127 6.2.6 Switched input impedance oscilloscopes 129 6.2.7 Instrument input impedance effects 130 6.2.8 Source loading and bandwidth 132 6.3 AC and RF/microwave traceability 133 6.3.1 Thermal converters and micropotentiometers 133 6.4 Impedance matching and mismatch errors 135 6.4.1 Uncertainty analysis considerations 136 6.4.2 Example: Oscilloscope bandwidth test 137 6.4.3 Harmonic content errors 137 6.4.4 Example: Oscilloscope calibrator calibration 138 6.4.5 RF millivoltmeter calibration 140 Further reading 143 7 Structures and properties of transmission lines 147 R. J. Collier 7.1 Introduction 147 7.2 Coaxial lines 148 7.3 Rectangular waveguides 150 7.4 Ridged waveguide 150 7.5 Microstrip 151 7.6 Slot guide 152 7.7 Coplanar waveguide 153 7.8 Finline 154 7.9 Dielectric waveguide 154 References 155 Further reading 156 8 Noise measurements 157 David Adamson 8.1 Introduction 157 8.2 Types of noise 158 8.2.1 Thermal noise 158 8.2.2 Shot noise 159 8.2.3 Flicker noise 159 8.3 Definitions 160 8.4 Types of noise source 162 8.4.1 Thermal noise sources 162 8.4.2 The temperature-limited diode 163 8.4.3 Gas discharge tubes 163 8.4.4 Avalanche diode noise sources 163 Contents ix 8.5 Measuring noise 164 8.5.1 The total power radiometer 164 8.5.2 Radiometer sensitivity 166 8.6 Measurement accuracy 166 8.6.1 Cascaded receivers 169 8.6.2 Noise from passive two-ports 169 8.7 Mismatch effects 171 8.7.1 Measurement of receivers and amplifiers 172 8.8 Automated noise measurements 174 8.8.1 Noise figure meters or analysers 175 8.8.2 On-wafer measurements 175 8.9 Conclusion 176 Acknowledgements 176 References 176 9 Connectors, air lines and RF impedance 179 N. M. Ridler 9.1 Introduction 179 9.2 Historical perspective 180 9.2.1 Coaxial connectors 180 9.2.2 Coaxial air lines 181 9.2.3 RF impedance 181 9.3 Connectors 182 9.3.1 Types of coaxial connector 182 9.3.2 Mechanical characteristics 185 9.3.3 Electrical characteristics 187 9.4 Air lines 188 9.4.1 Types of precision air line 189 9.4.2 Air line standards 190 9.4.3 Conductor imperfections 192 9.5 RF impedance 193 9.5.1 Air lines 194 9.5.2 Terminations 198 9.6 Future developments 200 Appendix: 7/16 connectors 201 References 203 10 Microwave network analysers 207 Roger D. Pollard 10.1 Introduction 207 10.2 Reference plane 208 10.2.1 Elements of a microwave network analyser 208 10.3 Network analyser block diagram 214 Further reading 216 x Contents 11 RFIC and MMIC measurement techniques 217 Stepan Lucyszyn 11.1 Introduction 217 11.2 Test fixture measurements 218 11.2.1 Two-tier calibration 220 11.2.2 One-tier calibration 229 11.2.3 Test fixture design considerations 230 11.3 Probe station measurements 230 11.3.1 Passive microwave probe design 231 11.3.2 Probe calibration 236 11.3.3 Measurement errors 240 11.3.4 DC biasing 240 11.3.5 MMIC layout considerations 241 11.3.6 Low-cost multiple DC biasing technique 243 11.3.7 Upper-millimetre-wave measurements 243 11.4 Thermal and cryogenic measurements 246 11.4.1 Thermal measurements 246 11.4.2 Cryogenic measurements 247 11.5 Experimental field probing techniques 249 11.5.1 Electromagnetic-field probing 249 11.5.2 Magnetic-field probing 250 11.5.3 Electric-field
Recommended publications
  • Dusting Off the Lecher Lines
    Dusting off the Lecher Lines Frank Thompson University of Manchester, Chemistry Department, (EPR Centre), Oxford Road, Manchester, M13 9PL Introduction It is quite some time since the article by Howes [1], concerning Lecher Lines, graced the pages of “Physics Education”. Historically, however, this apparatus invented in 1890 [2] was a pivotal point in the study of Radio Frequency (r.f.) waves as it allowed the wavelength/ frequency of such waves to be measured and, perhaps on this account, the topic should be given a more prominent place in the curriculum. In the 1960’s and 1970’s experiments with Lecher Lines were popular since they provided a means of unifying the physics of waves; standing waves detected on Lecher Lines had much in common with standing waves on vibrating strings or vibrating columns of air in an organ pipe. The cherished experiments: Kundt’s tube or “Measurement of the frequency of “Mains” electricity with a sonometer” were commonly used at A-level and beyond. The Lecher Line experiment also provided a good introduction to the subject of transmission lines. But the advent of Network Analysers in the 1980’s removed the need to employ standing wave techniques to study the propagation of r.f. and microwave radiation and, indeed, the slogan with practitioners of the time was S.O.S, Stamp Out Standing-waves. Inevitably the Lecher Lines apparatus was placed on the top of cupboards – out of sight and out of mind. In an attempt to redress the balance the following experiment on Lecher Lines will be presented. The apparatus can be constructed for a modest cost and the constructional details should not be beyond the capabilities of a Physics Laboratory workshop.
    [Show full text]
  • Leybold Note on Lecher Lines
    LEYBOLD Electricity Physics Electromagnetic oscillations and waves Leaflets P3.7.5.1 Propagation of microwaves along lines Guiding of microwaves along a Lecher line Objects of the experiments Generating standing microwaves on a Lecher line with shorted end. Demonstrating the standing wave character of the electric field strength. Determining the wavelength ␭ from the distances between the nodes of the electric field. Principles In 1890, E. Lecher proposed an arrangement of two parallel If the two wires are shorted at the end of the Lecher line, the round wires for investigating the propagation of electromag- voltage U is zero there. A reflected wave U2 is generated with netic oscillations. When a high-frequency electromagnetic a phase shift of 180Њ relative to the incoming wave. The two field is irradiated into a Lecher line, a voltage wave of the shape waves superimpose to form a standing wave, which has the ␲ shape = ⋅ ␲ ⋅ ⋅ − 2 ⋅ U1 U0 sin 2 f t x (I) ␲ ␭ = + = − ⋅ ⋅ 2 ⋅ ( ␲ ⋅ ⋅ ) U U1 U2 2 U0 sin ␭ x cos 2 f t (II) propagates in the direction x of the wires, whose frequency f and wavelength ␭ equal those of the irradiated electromagnetic if the wave comes in from “the left” and the shorting jumper is field. Corresponding to the voltage between the wires, a charge at x = 0. In this case, the locations of the voltage nodes are distribution arises along the wires, whose displacement leads ␭ 3␭ x = 0, – , –␭, – , … (III), to a current I through the wires, which propagates like a wave. 2 2 Thus an electromagnetic wave propagates along the Lecher ␭ line.
    [Show full text]
  • SWR Meters Make You Stupid Or Ladder Line To
    SWR Meters Make You Stupid Or Ladder Line to Eternity It may have already occurred to you that it might be desirable to locate your amateur radio antenna at some distance from your transmitter and/or receiver. In fact, unless you intend to operate your station from the top of a tree or a tower, it is very likely that you will be employing some form of transmission line. The purpose of a transmission line is to convey radio frequency energy from a radio set to an antenna, or vice versa, in as painless a fashion as possible. You can think of a transmission line as an extension cord for R.F. In fact, for the lower regions of the radio frequency spectrum, actual extension cord can serve reasonably well, for reasonable distances. Like so many other facets of Amateur Radio, the transmission line seems to have taken on a life of its own, accumulating a vast, sticky, woolly hairball of misinformation along the way. This is all so unnecessary. A transmission line is a means to an end, never an end in itself. And don't let anyone tell you otherwise. A Bit of History In the early years of radio, there wasn't much of a line of demarcation between a transmission line and an antenna. In fact, let's look at a very typical amateur radio antenna of days past. It consisted of an array of parallel wires, or “flat-top” arranged much like a clothes line, and a SINGLE WIRE leading from the flat top to the transmitter.
    [Show full text]
  • Antenna Trainer Dl 2594N
    TELECOMMUNICATIONS ANTENNA TRAINER DL 2594N The trainer has been designed to introduce students to the comprehension of the antenna’s operation mode. TECHNICAL FEATURES: The trainer includes: basic panel with generator, Lecher line, RF detector, mobile receiver, joint for fixing to the base, supporting base for receiver, reflector, locking knob, shielded connecting cable between the Lecher line and the detector with banana plugs, diam. 2 mm (length = 60 cm), set of cables for measuring and connections, coaxial support for antenna (mast) with turning base, ‘T’ BNC, set of 5 monopoles with banana terminations, different lengths, ground-plane antenna, Yagi antenna, folded dipole antenna, simple dipole antenna, coaxial cable RG59 with F/F BNC, length = 60 cm complete with M/M and F/F adapters. Working frequency: from 860 to 950 MHz. Input power supply: - 15 Vdc, 200 mA EXPERIMENTS: • The Lecher line • Polarization • The elementary dipole • The folded dipole • The Yagi antenna • The ground plane antenna • The matching stub NECESSARY MODULE: DL 2555ALG – Power Supply TELECOMMUNICATIONS EXPERIMENTS DESCRIPTION: Antenna trainer basic components studies As introductory experiment, its major role is to offer the opportunity to touch the components of the Antenna Trainer. Little by little, you will get familiar with the methods of handling Ultra High Frequency radio systems. You will see how difficult is to make a clean and not disturbed radio communication Study of the wavelength using the Lecher line With the Lecher Line module, you will study a short-circuited transmission line, by “visualizing” on a current measuring device, two maximum / minimum current point on an imaginary standing wave.
    [Show full text]
  • Modern Antennas and Microwave Circuits a Complete Master-Level
    i Modern Antennas and Microwave Circuits A complete master-level course by Prof. dr.ir. A.B. Smolders, Prof.dr.ir. H.J. Visser and dr.ir. Ulf Johannsen Electromagnetics Group (EM) Center for Wireless Technologies Eindhoven (CWT/e) Department of Electrical Engineering Eindhoven University of Technology, The Netherlands Draft Version 0.5, March 2019 ii Contents 1 Introduction 3 1.1 Purpose of this textbook . 3 1.2 Antenna functionality . 3 1.3 History of antennas . 4 1.4 Electromagnetic spectrum . 7 2 System-level antenna parameters 9 2.1 Coordinate system and time-harmonic fields . 9 2.2 Field regions . 10 2.3 Far field properties . 11 2.4 Radiation pattern . 13 2.5 Beam width . 14 2.6 Directivity and antenna gain . 15 2.7 Circuit representation of antennas . 15 2.8 Effective antenna aperture . 17 2.9 Polarisation properties of antennas . 18 2.10 Link budget analysis: basic radio- and radar equation . 20 3 Transmission line theory and microwave circuits 23 3.1 Introduction . 23 3.2 Telegrapher equation . 23 3.3 The lossless transmission line . 27 3.4 The terminated lossless transmission line . 28 3.5 The quarter-wave transformer . 32 3.6 The lossy terminated transmission line . 34 3.7 Field analysis of transmission lines . 36 3.8 The Smith chart . 38 3.9 Microwave networks . 40 3.10 Power Combiners . 44 3.11 Impedance matching and tuning . 51 3.12 Microwave filters . 55 iii CONTENTS 1 4 Antenna Theory 59 4.1 Maxwell's equations . 59 4.2 Radiated fields and far-field approximation .
    [Show full text]
  • Lecher Line with a Loop Dipole
    LD Electricity Physics Electromagnetic oscillations and waves Leaflets P3.7.3.2 Propagation of decimeter waves on lines Investigating the current and voltage on a Lecher line with a loop dipole Objects of the experiments Detecting the reflection-free propagation of a current and voltage wave on the Lecher line terminated with the loop dipole. Determining the current and the voltage maxima at the loop dipole. Principles When a high-frequency electromagnetic field is transmitted onto a Lecher line, a voltage wave U = U0 ⋅ sin(vt − kx), p v = pn = 2 2 , k l propagates in the direction x of the wires. The frequency n and the wavelength l of this wave agree with those of the trans- mitted field. The voltage between the wires is associated with a charge distribution along the wires. The displacement of these charges leads to a current in the wires which propagates as a wave. At the end of the Lecher line, the waves are reflected if the two ends of the wires are open or short-circuited. The incoming and the reflected wave then interfere to form a standing wave. If, however, the ends of the wires are connected by an ohmic resistor which is equal to the characteristic wave impedance of the Lecher line, then no reflection occurs and no standing waves arise. The same is true when the loop dipole terminates the Lecher line. The current and voltage maxima can then be found at the loop dipole The reflection-free propagation along the Lecher line is proven in the experiment by successively sliding a probe with lamp and an induction loop with lamp along the Lecher line at a fixed distance.
    [Show full text]
  • Early German and American Radar Transmitter Technology 1
    Copyright 2002 by Hans H. Jucker. Published in the Tube Collector Association Bulletin, Medford OR 97501, U.S.A. October 2002 Early German and American Radar Transmitter Technology Initially radar engineers worked with commercially available transmitter tubes. The very high voltage operation in radar transmitters caused serious positive ion bom­ bardments of the cathode. Therefore only tungsten cathodes or thoriated tungsten cathodes with their rather limited electron emission were sufficiently robust for this service. In 1937 Dr. Felix Herringer of the Lorenz electron tube laboratory mastered the development of an oxide cathode tube, suitable for pulse modulated UHF radar transmitters. The C. Lorenz company filed 1938 for the new type of tube, the patent Nr. 862782 “Anodenimpulsmodelung bei Röhren mit Oxydkathode” The photo shows the first laboratory sample of the Lorenz DS 323 pulse type UHF triode developed 1937. The DS 323 was the first pulse type transmitter tube with oxide cathode, suitable for radar transmitters. The oxide cathode with the higher electron emission (>5 amps. plate saturation current) made it possible to generate much higher RF output powers. The power dissipation of the heavy plate construction, containing several heat sinks, was 75 watts. The tube didn’t need a getter because of the tantalized plate surface. In 1938 Dr. Gotthard Mueller of the C. Lorenz labora­ tory at Berlin, developed with two DS 323 tubes a pulse modulated push pull transmitter for the 500 MHz band. The C. Lorenz company filed for this new kind of transmitter on 10th April 1938 the patent Nr. 767453 “Anordnung zur Erzeugung bzw.
    [Show full text]
  • Parallel Circular Conductor Transmission Line Calculator Serge Y
    Parallel Circular Conductor Transmission Line Calculator Serge Y. Stroobandt, ON4AA Copyright 2015–2020, licensed under Creative Commons BY-NC-SA Introduction This calculator is a tool for designing balanced transmission lines with a specif- ic desired characteristic impedance Zc and made of parallel circular conductors of a given diameter d.Round open wire Lecher line, ladder or window line and twin‑lead line are all balanced transmission lines which are frequently encoun- tered as the feed line of severely mismatched multi-band wire antennas, espe- cially the G5RV antenna. The conductors being massive or hollow does not af- fect the characteristic impedance. Figure 1: Parallel circular conductor transmission line; dimensions. Construction Here is an excellent construction suggestion by Leon Salden, VK3VGA. He de- vised a ladder line spreader built from durable and readily available materi- als; a black cable tie and black polyethylene (PE) irrigation extension tube. For smaller separation distances, black LED spacers can also be used. 1 Figure 2: Ladder line spreader built from black irrigation extension tube and a cable tie. Source: Leon Salden, VK3VGA Formulas Following formula can be derived for the characteristic impedance of a parallel wire transmission line:1 (1) The characteristic impedance of free space is exactly: (2) where: m c0 = 299 792 458 s : the speed of light in free space − 7 H μ0 = 4π ⋅ 10 m : the free space permeability 1 ϵ0 = : the absolute permittivity of free space μ c2 0 0 Z0: the characteristic impedance of free space Rearranging and solving Eq. 1 for D: (3) 2 (4) where: D: the centre to centre distance d: the diameter of the circular conductors Zc: the desired characteristic impedance of the transmission line Z0: the characteristic impedance of free space ϵr: the relative dielectric constant of the surrounding medium (1.00054 for air) s: the space between the circular conductors Brython source code Here is the Brython code of this calculator.
    [Show full text]
  • Ladder Line to Eternity Or SWR Meters Make You Stupid It May
    Ladder Line to Eternity Or SWR Meters Make You Stupid It may have already occurred to you that it might be desirable to locate your amateur radio antenna at some distance from your transmitter and/or receiver. In fact, unless you intend to operate your station from the top of a tree or a tower, it is very likely that you will be employing some form of transmission line. The purpose of a transmission line is to convey radio frequency energy from a radio set to an antenna, or vice versa, in as painless a fashion as possible. You can think of a transmission line as an extension cord for R.F. In fact, for the lower regions of the radio frequency spectrum, actual extension cord can serve reasonably well, for reasonable distances. Like so many other facets of Amateur Radio, the transmission line seems to have taken on a life of its own, accumulating a vast, sticky, woolly hairball of misinformation along the way. This is all so unnecessary. A transmission line is a means to an end, never an end in itself. And don’t let anyone tell you otherwise. A Bit of History In the early years of radio, there wasn’t much of a line of demarcation between a transmission line and an antenna. In fact, if you look at Bo Tanker’s haunted house cartoon on the first page of this book, you will see a very typical amateur radio antenna of days past. It consisted of an array of parallel wires, or “flat-top” arranged much like a clothes line, and a SINGLE WIRE leading from the flat top to the transmitter.
    [Show full text]
  • Basic Rf Theory, Waveguides and Cavities
    BASIC RF THEORY, WAVEGUIDES AND CAVITIES G. Déme CERN, Geneva, Switzerland ABSTRACT After a brief mathematical introduction, Maxwell's equations are discussed in their most general form as known today. Plane waves are considered in unbounded media, with the laws of reflection and refraction at a planar interface. A general theory of waveguides and cavities is then developed in detail. Periodically loaded waveguides are given as an example of accelerating structure. The parameters which characterize the interaction of resonant cavities with a particle beam are introduced, for both longitudinal and transverse motions. 1 . MATHEMATIC AL REPRESENTATION OF PHYSICAL VARIABLES AS A FUNCTION OF TIME 1 . 1 Sinusoidal variables (time-harmonic electromagnetic fields) Phasors Real sinusoidal variables a(t) = am cos (cot + tp) are represented as Rea¤’(°"*°)=l,,,] ReA[u] cf (1.1) where A el"' (with to 2 0) is called a phasor and A = dm ef'? is its complex amplitude. When the differential equations determining the physical variable a(t) are linear with real coefficients, any complex solution of the type A elm yields two real solutions which represent physical quantities: Re(A ew)l = |A| cos (mz + q>) Irn(A e)lw = |A| sin (mz + rp) Since these solutions merely differ by the time origin, it is sufficient to keep only the first one. A (capital letter) is the complex amplitude of the real sinusoidal variable a(z) written as a lower case letter. IAI is the amplitude am; arg (A) = o is the phase of a(t). In Eq. (1.1), the phasor A el"' may be replaced by its complex conjugate; in fact both conventions are used in the literature.
    [Show full text]
  • Radio Science Bulletin Staff
    INTERNATIONAL UNION UNION OF RADIO-SCIENTIFIQUE RADIO SCIENCE INTERNATIONALE ISSN 1024-4530 Bulletin Vol. 2018, No. 369 June 2019 Radio Science URSI, c/o Ghent University (INTEC) Technologiepark - Zwijnaarde 126, B-9052 Gent (Belgium) Contents Radio Science Bulletin Staff ....................................................................................... 3 URSI Offi cers and Secretariat.................................................................................... 6 Editor’s Comments ..................................................................................................... 8 Historical Corner Column ......................................................................................... 9 Ernst Lecher and His Wires ..................................................................................... 10 URSI GASS 2020: Call for Papers .......................................................................... 18 URSI Young Scientist Awards .................................................................................. 19 Et Cetera .................................................................................................................... 20 EUCAP 2020 .............................................................................................................. 21 Solution Box: SOLBOX-16: Nano-Link Systems................................................... 22 European School of Antenaas 2019 ......................................................................... 28 Ethically Speaking: Whataboutery ........................................................................
    [Show full text]
  • 電子回路論第3回 Electric Circuits for Physicists #3
    電子回路論第8回 Electric Circuits for Physicists #8 東京大学理学部・理学系研究科 物性研究所 勝本信吾 Shingo Katsumoto Outline Various transmission lines Termination and connection Smith chart S-matrix (S-parameters) Transmission lines with TEM mode Transmission lines with two conductors are “families”. Electromagnetic field confinement with parallel-plate capacitor Roll up to coaxial cable Open to micro-strip line Commonly TEM is the primary mode. Shrink to dipole (Lecher line) Lecher line Micro strip line Wide (W/h>3.3) strip Narrow (W/h<3.3) strip Waveguide Electromagnetic field is confined into a simply- cross section connected space. metal TEM mode cannot exist. hollow Maxwell equations give Helmholtz equation 퐸푧 = 0: TE mode, 퐻푧 = 0: TM mode Optical fiber Difference in dielectric constant step-type optical fiber no dispersion Connection and termination 퐽 = 퐽 + 퐽 (definition right positive) 푍0 + − At 푥 = 0: progressive retrograde 푍1 푉 = 푉+ + 푉− = 푍0 퐽+ − 퐽− x -l 0 Termination of a transmission line with length l and Reflection coefficient is characteristic impedance 푍0 at 푥 = 0 with a resistor 푍1. 푍1 = 푍0 : no reflection, i.e., impedance matching Comment: Sign of Ohm’s law in transmission lines 푍1 = +∞ (open circuit end) : 푟 = 1, i.e., free end reflects direction of waves (depends on the definitions). 푍1 = 0 (short circuit end) : 푟 = −1, i.e., fixed end Connection and termination Finite reflection → Standing wave Voltage-Standing Wave Ratio (VSWR): 1 − |푟| 1 + |푟| At 푥 = −푙 Then at 푥 = −푙 (at power source), the right hand side can be represented by Reflection coefficient: Connection and termination Transmission line connection.
    [Show full text]