Federal Signal Intercoms

Total Page:16

File Type:pdf, Size:1020Kb

Federal Signal Intercoms FEDERAL SIGNAL CORPORATION AudioMaster ® Two-Way Intercom Model .310-MV Federal.Signal’s.AudioMaster®.310-MV.is.an.industrial.intercom. that.provides.reliable.two-way.communications.and.superior.sound. TWO-WAY INTERCOM quality..This.unit.has.a.rugged.Type.4X.housing.and.is.UL.Listed.and. WITH SUPERIOR CSA.Certified. SOUND QUALITY The.AudioMaster.310-MV’s.standard.features.include.volume.. control,.call.button,.balanced.line.output,.dust-.and.water-tight. •. Multi-voltage.design.accepts. housing,.listen/talk.switch,.remote.device.activation.and.the.ability. to.power.another.intercom.at.24VDC. 24VDC.and.120VAC/240VAC This.heavy.duty.intercom.will.operate.from.-31°F.to.150°F.. •. Heavy-duty.industrial.intercom.for. (-35°C.to.66°C).in.both.indoor.and.outdoor.applications..Remote. indoor.or.outdoor.applications device.activation.allows.you.to.activate.an.auxiliary.signal.such.as.a. horn.or.light. •. Balanced.line.output The.AudioMaster.310-MV.requires.24VDC,.120VAC.or.240VAC.to. •. Type.4X,.IP56.enclosure power.each.unit..The.intercom.is.easy.to.operate..Press.the.switch. down.to.talk.and.release.to.listen. •. UL.Listed,.CSA.Certified. and.Marine.Listed The.310-MV.is.ideal.for.use.at.oil.refineries,.petrochemical.plants,. offshore .platforms,.pulp.and.paper.mills,.water.treatment.facilities,. airports,.shipyards.or.anywhere.reliable.two-way.communication.is. important.for.safe.and.efficient.operation. Operating Standby Frequency Input Model Voltage Current Current Response (-6dB) Impedance 310-MV. 24VDC. 260mA. 62mA. 150Hz-12KHz. 3400.ohms 120VAC.50/60Hz. 163mA. 70mA. 150Hz-12KHz. 3400.ohms 240VAC.50/60Hz. 82mA. 35mA. 150Hz-12KHz. 3400.ohms yry 5W T Y A R R A N Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com TWO-WAY INDUSTRIAL INTERCOM (310-MV) Speaker/Microphone 9.88"/ 251 mm Volume Control TM LISTEN V AudioMasterMODEL 310-M TALK .S.A. Listen/Talk Switch FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U VOLUME CALL 5"/ WARNING: DISCONNECT POWER BEFORE REMOVING COVER 127 mm 6.5"/ 165.1 mm Call Button 290A3022 SPECIFICATIONS HOW TO ORDER Speaker.Rating:. 30.Watt. 30.Watt •. Specify.model.number Operating.Temperature:. -31°F.to.150°F. -35°C.to.66°C •. Optional.Accessories:. Net.Weight:. 9.9.lbs.. 4.5.kg . Slave.Kit.(K8502017A) Shipping.Weight:. 11.5.lbs.. 5.2.kg •. Please.refer.to.Model.Number.Index. Height:. 9.88". 251.0.mm 310-MV.beginning.on.page.376 Width. 6.5". 165.1.mm Depth:. 5.0". 127.0.mm REPLACEMENT PARTS Description Part Number Description Part Number PC.Board.Assembly. K2001915B. Kit,.potentiometer. K8590237A Connector,.10.pin. K140A326A-01. Kit,.toggle.switch. K8590298A Resistor,.1K,.1W. K101216A. Kit,.call.button.and.boot. K8590241A Fuse.250V,.1/2.Amp. K148A155A. Permanent.Slave.Kit. K8502017A Fuse.250V,.1.Amp. K148A155A-01. Gasket,.rubber. K8590013B 2645.Federal.Signal.Dr.,.University.Park,.IL.60484...Tel:.708.534.4756....Fax:.708.534.4852....www.federalsignal-indust.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com FEDERAL SIGNAL CORPORATION AudioMaster ® Hazardous Location Two-way Intercom Model 310X-MV Federal Signal’s AudioMaster® 310X-MV is a two-way industrial intercom that provides reliable communications and superior sound INTERCOM FOR HIGH quality. This unit has a rugged Type 4X housing and is rated for AMBIENT NOISE Class I, Division 2, Groups A, B, C, & D; Class II, Division 2, Groups F ENVIRONMENTS & G; and Class III. The AudioMaster 310X-MV’s standard features include volume con- trol, call button, balanced line output, dust- and water-tight housing, • Multi-voltage design accepts listen/talk switch, remote device activation, and the ability to power 24VDC, 120VAC and 240VAC another intercom at 24VDC. • Heavy-duty industrial intercom for This heavy duty intercom will operate from -31°F to 149°F (-35°C to 65°C) for both indoor and outdoor applications. Remote device indoor or outdoor applications activation allows you to activate an auxiliary signal such as a horn • Balanced line output or light. The AudioMaster 310X-MV requires 24VDC, 120VAC or 240VAC to power each unit. The intercom is easy to operate. Press • Rated for Class I, Division 2 the switch down to talk and release to listen. • Type 4X, IP65 enclosure The AudioMaster is UL Listed and CSA Certified. The 310X-MV is ideal for use at oil refineries, petrochemical plants, • UL and cUL Listed, CSA Certified offshore platforms, pulp and paper mills, water treatment facilities, and Marine Listed airports, shipyards or anywhere reliable two-way communication is important for safe and efficient operation. Operating Standby Frequency Input Model Voltage Current Current Response (-6dB) Impedance 310X-MV 24VDC 260mA 62mA 150Hz-12KHz 3400 ohms 120VAC 50/60Hz 163mA 70mA 150Hz-12KHz 3400 ohms 240VAC 50/60Hz 82mA 35mA 150Hz-12KHz 3400 ohms Hazardous Location Rating: T-Code at Maximum Ambient Temperature, °C Hazardous Location 40°C 66°C yry Class I, Div 2, Groups A, B, C, D T6 T5 Class II, Div 2, Groups F, G T6 T5 5W T Y A R R A N Class III T6 T5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com TWO-WAY INDUSTRIAL INTERCOM (310X-MV) Speaker/Microphone 9.88"/ 251 mm Volume Control TM LISTEN V AudioMasterMODEL 310-M TALK .S.A. Listen/Talk Switch FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U VOLUME CALL 5"/ WARNING: DISCONNECT POWER BEFORE REMOVING COVER 127 mm 6.5"/ 165.1 mm Call Button 290A3022 SPECIFICATIONS HOW TO ORDER Speaker Rating: 30 Watt 30 Watt • Specify model number Operating Temperature: -31°F to 149°F -35°C to 65°C • Please refer to Model Number Index Net Weight: 10.1 lbs. 4.6 kg 310X-MV beginning on page 376 Shipping Weight: 12.0 lbs. 5.4 kg Height: 9.88" 251.0 mm Width 6.5" 165.1 mm Depth: 5.0" 127.0 mm REPLACEMENT PARTS Description Part Number Description Part Number PC Board Assembly K2001915B-02 Kit, potentiometer K8590237A Connector, 10 Pin K140A326A-01 Kit, toggle switch K8590298A Resistors, 1K, 1W K101216A Kit, call button and boot K8590241A Fuse 250V, 1/2 Amp K148A155A Fuse 250V, 1 Amp K148A155A-01 Gasket, rubber K8590013B 2645 Federal Signal Dr., University Park, IL 60484 Tel: 708.534.4756 Fax: 708.534.4852 www.federalsignal-indust.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com FEDERAL SIGNAL CORPORATION AudioMaster ® Two-way Intercom with Noise Canceling Microphone Model .310-MV-MNC Federal.Signal’s.AudioMaster®.310-MV-MNC.is.a.two-way. industrial.intercom.that.provides.reliable.communications.and. INTERCOM FOR HIGH superior.sound.quality.. AMBIENT NOISE The.AudioMaster.310-MV-MNC’s.standard.features.include.. ENVIRONMENTS volume .control,.call.button,.balanced.line.output,.listen/talk. switch,.remote.device.activation,.and.the.ability.to.power.another. intercom.at.24VDC. •. Multi-voltage.design.accepts. This.heavy.duty.intercom.will.operate.from.-31°F.to.150°F.. 24VDC,.120VAC.and.240VAC (-35°C.to.66°C)..The.remote.device.activation.feature.allows. youo .t .activate.an.auxiliary.signal.such.as.a.horn.or.light..The. •. Heavy-duty.industrial.intercom AudioMaster.310-MV-MNC.requires.24VDC,.120VAC.or.240VAC.to. •. Noise.canceling.microphone power.each.unit..The.intercom.is.easy.to.operate..Press.the.switch. down.to.talk.and.release.to.listen. •. Balanced.line.output When.the.ambient.noise.level.is.too.high.for.the.standard.310-MV. •. Type.3R.enclosure integrated.microphone,.the.310-MV-MNC.noise.canceling.unit.is. used.to.improve.transmission.quality. •. UL.Listed,.CSA.Certified. The.310-MV-MNC.is.ideal.for.use.at.oil.refineries,.petrochemical. and.Marine.Listed plants,.offshore.platforms,.pulp.and.paper.mills,.water.treatment. facilities, .airports,.shipyards.or.anywhere.reliable.two-way.. communication.is.important.for.safe,.efficient.operation. Operating Standby Frequency Input Model Voltage Current Current Response (-6dB) Impedance 310-MV-MNC. 24VDC. 260mA. 62mA. 150Hz-12KHz. 3400.ohms 120VAC.50/60Hz. 163mA. 70mA. 150Hz-12KHz. 3400.ohms 240VAC.50/60Hz. 82mA. 35mA. 150Hz-12KHz. 3400.ohms yry 5W T Y A R R A N Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com TWO-WAY INDUSTRIAL INTERCOM (310-MV-MNC) Speaker 9.88" 251 mm TM LISTEN Listen/Talk Switch AudioMaster VDC MODEL 310-012 TALK VOLTS: 12/24 FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A. VOLUME 5"/ CALL 127 mm WARNING: DISCONNECT POWER BEFORE REMOVING COVER Call Button Volume Control SPECIFICATIONS HOW TO ORDER Speaker.Rating:. 30.Watt. 30.Watt •. Specify.model.number Operating.Temperature:. -31°F.to.150°F. -35°C.to.66°C •. Please.refer.to.Model.Number.Index. Net.Weight:. 10.1.lbs.. 4.6.kg 310-MV-MNC.beginning.on.page.376 Shipping.Weight:. 12.0.lbs.. 5.4.kg Height:. 9.88". 251.0.mm Width. 6.5". 165.1.mm Depth:. 5.0". 127.0.mm REPLACEMENT PARTS Description Part Number Description Part Number PC.Board.Assembly. K2001915B. Kit,.potentiometer. K8590237A. Connector. K140A326A-01. Kit,.toggle.switch. K8590298A Fuse.250V,.1/2.Amp. K148A155A. Kit,.call.button.and.boot. K8590241A Fuse.250V..1.Amp. K148A155A-01. Resistors,.1K,.1W. K101216A. Microphone. MNC-MC. Gasket,.rubber. K8590013B . .. 2645.Federal.Signal.Dr.,.University.Park,.IL.60484 .Tel:.708.534.4756 Fax:.708.534.4852 www.federalsignal-indust.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com FEDERAL SIGNAL CORPORATION AudioMaster ® Light Duty Two-Way Intercom Model .310LD-MV Federal .Signal’s.AudioMaster®.
Recommended publications
  • Clear-Com Encore Brochure V901
    Encore™ Party-line Communication Systems Raising Performance Raising Performance to New Levels Clear, reliable, and proven party-line communication solutions Based upon Clear-Com’s market proven communication Clear-Com Encore is highly compatible with other Clear-Com or technology, Clear-Com Encore™ delivers improved audio third-party components. This level of flexibility enables users to performance and offers a more streamlined, contemporary and assemble the right system for their unique needs and can easily user-intuitive design. scale to support the growing production environment. All components are constructed and proven to withstand Clear-Com party-line intercom systems are widely used in live rugged usage in fast-paced, demanding and high intensity performance theaters, concert halls and sport stadiums. They applications. Even under the most challenging conditions, the are also found in small to mid-sized TV/broadcast studios, noise attenuating headsets and noise-cancelling microphones, smaller broadcast production trucks, industrial settings, houses combined with anti-sidetone circuitry, minimize acoustic noise of worship and in simulation applications. and feedback to provide superior sound quality. 2 Clear-Com Encore™ Product Family Overview Clear-Com® delivers the most comprehensive set of party-line intercom systems in the world. From main stations to remote stations, wall-mounted speaker stations to multi-channel beltpacks, robust interfaces, headsets, announcer console and more. 2-Channel Main/Remote Beltpacks Que-COM Stations
    [Show full text]
  • Legrand Home Systems
    On-Q/Legrand® Home Systems On-Q/Legrand ® Home Systems F7400-WH F7602 F7810 Wiring today’s homes to meet the new needs of today’s homebuyers — structured wiring systems, wireless access points for data distribution, Category 5 intercom systems and cameras, high efficiency speakers, home theater and multi-room audio, and integration products for seamless connectivity with other systems. Index Section Page Number Infrastructure O-4 – O-37 Enclosures, Custom Rack Drawer, Network Centers, Power Management, Keystone Wall Plates & Jacks, Decorator Wall Plates, ValuePort Wall Plates & Outlets, AnyPort Designer Wall Plates, Hide-A-Port Outlets, AnyPort Decorator Outlets, AnyPort Inserts, AnyPort Outlet Kits, Installation Tools, Mounting Plates Entertainment O-38 – O-57 Video Modules, Digital Satellite Modules, Video Engine Module, Video Accessories, lyriQ™ Audio System, ev¯oQ™ Speakers, Impedance Audio System, Home Entertainment Connection Center Communications O-58 – O-73 Combo Modules, Combo Kits, Apartment Kits, Telecom Modules, Telecom Conditioning Units & Accessories, Wireless Access Point, Networking Modules, Intercom System Comfort O-74 – O-95 On-Q Lighting Controller, Advanced Lighting Control (ALC), Power Line Carrier (PLC) Lighting Control, Category 5 Cameras, LCD Display, Home Management System O-1 Build more solutions with Pass & Seymour/Legrand and On-Q/Legrand product lines. Three market leaders, one great source. How can Pass & Seymour/Legrand offer you convenient access to everything you need? We’ve brought three great companies together – P&S, On-Q, and Greyfox. On-Q Home and Greyfox Home Systems have become On-Q/Legrand – a company providing unmatched systems solutions, effective marketing tools, and product innovations to the connected home.
    [Show full text]
  • A Comprehensive Guide to Clear-Com Analog and Digital Partyline Systems
    A Comprehensive Guide to Clear-Com Analog and Digital Partyline Systems Introduction & Acknowledgments Clear-Com’s original development of Partyline intercom effectively created the platform to coordinate live performance technical teams as now we know it. As part of our 50th anniversary, it is an appropriate time to document our Partyline communications platform—both analog and digital formats in this Reference Guide. I use the word “platform” in a very intentional way, as this Guide explains the technology in general terms and comprehensively covers the Partyline concept, as opposed to how it is handed in the specific manuals of a particular product. Many sources were mined for creating this Reference Guide, including the Clear-Com Analog Partyline Intercom Installation Manual for written in 1988 and revised in 1997, scores of product manuals and technical training materials amassed over decades, and the Clear-Com ‘Solution Finder’ which resides on our website. New to this Guide is the inclusion of the HelixNet Digital Network Partyline, with the purpose of offering the same kind of broad understanding of how the two platforms may fit together for providing a single working solution. A critical aspect of this work includes documenting contemporary wiring standards and their impact on the deployment of our solutions. Given Clear-Com’s broad history in Partyline intercom, many people have contributed to this body of work, but two people must be recognized by name. First and foremost: Charles ‘Charlie’ Butten – creator of analog Partyline ‘Clear-Com’ technology and a continual inspiration for all intercom specialists. Charlie’s contributions to Clear- Com can’t be overstated.
    [Show full text]
  • Facts You Should Know About Wired Intercom Systems for Your Business
    Facts You Should Know About Wired Intercom Systems for Your Business How to Choose the Best Wired Intercom System For Increased Productivity Without Worry About Choosing the Wrong System. By: IntercomsOnline.com LLC 8161 Highway 100, #194 Nashville, TN 37221 888-298-9489 www.IntercomsOnline.com [email protected] Page 1 of 8 © 2012 IntercomsOnline.com Summary In this guide you'll find information about the different types of intercom systems you'll see while searching for a system. It discusses technology used, types of wire required, and the advantages and disadvantages of each type. After reading it you'll be able to better define what type of system will be best for your application. Thank you, David Onslow, Marketing Director www.IntercomsOnline.com [email protected] Introduction As you scroll through the online search results for intercoms, no doubt you've seen a confusing array of choices for wired intercoms. You are faced with decisions of whether to purchase wired or wireless; 2-wire, or Cat-5; video or voice only; full-featured or basic features only. You can even purchase systems that transmit and receive over your house or business power lines. You're likely reading this because your business has a communication problem and you have the task of solving it. Also likely is that intercom systems are probably not your area of expertise and you don't have a lot of time to become an expert. But the last thing you want to do is spend a bunch of money and waste time on a solution that won't solve your communication issue.
    [Show full text]
  • How to Choose a Two-Way Radios and Other Wireless
    www.IntercomsOnline.com How to Choose a Commercial Intercom System or Two Way Radio. By David Onslow Copyright 2014, IntercomsOnline.com, all rights reserved 1st Edition v1.0 For assistance in choosing the right two-way radio or communication product for you, visit www.intercomsonline.com or email us at the following address: 888-298-9489 2 www.IntercomsOnline.com Introduction ..................................................................................................................................................... 6 Commercial Intercom Systems ........................................................................................................................ 6 Wireless Intercom and 2-Way Radio Range: How Far Can They Communicate? ............................................ 7 Radio Power ................................................................................................................................................ 8 Radio Frequencies ...................................................................................................................................... 9 UHF Radio ................................................................................................................................................ 10 VHF Radio ................................................................................................................................................. 11 MURS Wireless Intercom .............................................................................................................................
    [Show full text]
  • Clear-Com Encore Tw-47 Two-Way Radio Interface Instruction Manual
    CLEAR-COM ENCORE TW-47 TWO-WAY RADIO INTERFACE INSTRUCTION MANUAL TW-47 Two-Way Radio Interface Instruction Manual © 2007 Vitec Group Communications Ltd. All rights reserved. Part Number 810502Z Rev. 2 Vitec Group Communications, LLC. 850 Marina Village Parkway Alameda, CA 94501 U.S.A Vitec Group Communications 7400 Beach Drive Cambridge Research Park Cambridgeshire United Kingdom CB25 9TP Vitec Group Communications Room 1806, Hua Bin Building No. 8 Yong An Dong Li Jian Guo Men Wai Ave Chao Yang District Beijing, P.R. China 100022 ® Clear-Com,CellCom/FreeSpeak and the Clear-Com Communication Systems logo are registered trademarks of The Vitec Group plc. CONTENTS OPERATION . 1-1 Introduction . 1-1 Before you Begin . 1-1 Features of the TW-47 System. 1-1 Description of the TW-47 . 1-2 RF Interference . 1-3 Connecting the TW-47 to the Base Station Radio . 1-3 Building Your Custom Cable . 1-4 Option Settings . 1-7 Output Level Jumpers . 1-8 Transmit Key Jumper. 1-9 Call Signal Frequency Adjust . 1-9 Check Out and Operation of the TW-47 System . 1-9 TW-47 Front Panel Controls and Lights . 1-11 Rear Panel of TW-47. 1-12 INSTALLATION. 2-1 Wiring Cables for Specific Radio Types . 2-1 For Motorola: Radius, GP300, SP-50, and Sport 7x2-1 For Yaesu: FT-411, 811, 911; FT-415, 815; FT-530; FT- 416, 816; FT-11R, 41R . 2-1 For Uniden: Model SPH; Motorola: Radius P-50 . 2-2 SPECIFICATIONS. 3-1 TW-47 TWO-WAY RADIO INTERFACE i TW-47 Technical Specifications.
    [Show full text]
  • Rts Intercom
    HEADQUARTER ADDRESSES NORTH AMERICA GLOBAL HQ Bosch Security Systems, Inc. Burnsville, MN Phone: +1 952 884 4051 RTS INTERCOM LATIN AMERICA REGIONAL HQ Robert Bosch Limitada Security Systems Campinas, SP, Brasil Phone: +55 19 2103-4282 [email protected] SYSTEMS EUROPE REGIONAL HQ Bosch Sicherheitssysteme GmbH (EVI Audio GmbH) PRODUCT CATALOG Straubing, Germany Phone: +49 9421 706-0 [email protected] ASIA-PACIFIC REGIONAL HQ Robert Bosch (SEA) Pte Ltd Singapore Phone: +65 6571 2808 CHINA REGIONAL HQ Bosch (Shanghai) Security Systems Ltd. IBP, Changning District Shanghai, P.R.China Phone: +86 400 8310 669 [email protected] For information on any of the products featured in this catalog, you can reach us at [email protected] Please visit the RTS website at: www.rtsintercoms.com @rtsintercoms @rtsintercomsystems @rtsintercoms @rtsintercoms 09/2019, Bosch Security Systems, Inc. Information in this document is subject to change without notice. All trademarks are the copyrights of their respective owners. 2 3 TABLE OF CONTENTS TABLE PREFACE Preface .................................................................... 3 WIRED PARTYLINE................ 46–54 RTS is the industry leader in professional intercom A top priority for us is the backwards compatibility of RTS Core Technologies ........................................... 4 systems, providing solutions that combine forward- our new products, so they can integrate seamlessly Power Supply .................................................. 46 thinking functionality, real-world reliability and superior with legacy systems to extend the value of the initial Master Station ................................................. 47 sound quality. investment. RTS offers the widest variety of matrix DIGITAL MATRIX ........................6–31 User Stations ................................................... 47 interfaces in the market: RVON (VoIP), MADI and Intercom Matrices ............................................. 6 Universal Beltpacks .......................................
    [Show full text]
  • Rts Intercom
    HEADQUARTER ADDRESSES NORTH AMERICA GLOBAL HQ Bosch Security Systems, Inc. Burnsville, MN Phone: +1 952 884 4051 RTS INTERCOM LATIN AMERICA REGIONAL HQ Robert Bosch Limitada Security Systems Campinas, SP, Brasil Phone: +55 19 2103-4282 [email protected] SYSTEMS EUROPE REGIONAL HQ Bosch Sicherheitssysteme GmbH (EVI Audio GmbH) PRODUCT CATALOG Straubing, Germany Phone: +49 9421 706-0 [email protected] ASIA-PACIFIC REGIONAL HQ Robert Bosch (SEA) Pte Ltd Singapore Phone: +65 6571 2808 CHINA REGIONAL HQ Bosch (Shanghai) Security Systems Ltd. IBP, Changning District Shanghai, P.R.China Phone: +86 400 8310 669 [email protected] For information on any of the products featured in this catalog, you can reach us at [email protected] Please visit the RTS website at: www.rtsintercoms.com @rtsintercoms @rtsintercomsystems @rtsintercoms @rtsintercoms 09/2019, Bosch Security Systems, Inc. Information in this document is subject to change without notice. All trademarks are the copyrights of their respective owners. 2 71 Headsets Microphone sensitivity Microphone Microphone Speaker Speaker Speaker Connector Cord Weight Product Type (re: 1V/Pa @ frequency impedance sensitivty frequency impedance Termination length (not inclu- 1KHz) response repsonse ding cord) Available in 4 or Single Side, 5 pin Male XLR, 6ft ~2.6oz LH-300-DM Dynamic -63 dB 200Hz – 6.5KHz 200Ω 99 dB 200 Hz - 10KHz 300Ω 4 pin Female XLR (1.8M) (74g) Microphone or stripped wire Single Side, 4 conductor 6ft ~2.6oz LH-300-EM Electret -41 dB 200Hz - 10KHz 2.2K 99 dB 200 Hz
    [Show full text]
  • Handbook of Intercom Systems Engineering
    HANDBOOK OF INTERCOM SYSTEMS ENGINEERING FIRST EDITION 38109-977 Rev. 4 The Fine Print The Handbook of Intercom Systems Engineering, first edition, Copyright© 2007 by Telex Communica- tions, Inc. All rights reserved. Printed in the United States of America. Except as permitted under the United States Copyright Act of 1976, no part of this publication may be reproduced or distributed in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage or retrieval system without the prior written permission of Telex Communications, Inc., unless such copying is expressly permitted by federal copyright law. Address copying inquires to: Bosch Communications Systems Telex Communications, Inc. Attn: Intercom Department 12000 Portland Ave S Burnsville, Minnesota 55337 USA Information contained in this work has been created or obtained by Telex Communications Inc. from sources believed to be reliable. However, Telex Communications, Inc. does not guarantee the accuracy or completeness of the information published herein nor shall Telex Communications Inc. be liable for any errors, omissions, or dam- ages arising from the use of this information. Telex Communications, Inc. is not attempting to provide professional services through the publication of this book, but rather intends only to provide information. If such professional services are necessary or desired, users of this book should seek such professional assistance. TABLE OF CONTENTS Preface- - - - - - - - - - - - - - - - - - - - - - -
    [Show full text]
  • Intercom Systems
    REFERENCES AEQ INTERCOM SYSTEMS 2016 to 2019 Updated December 2019 AEQ Intercom System AEQ Tel: INTERCOM(+34) 91 686 13 00 - Email: [email protected]| AUDIO - Web:| VIDEO www.aeq.eu | COMUNICACIÓN Index AFRICA ................................................................................................................................... 2 AMERICAs .............................................................................................................................. 5 ASIA ..................................................................................................................................... 21 EUROPE ............................................................................................................................... 28 MIDDLE EAST ........................................................................................................................ 69 AEQ Intercom System 1 AEQ Tel: (+34) 91 686 13 00 - Email: [email protected] - Web: www.aeq.eu AFRICA ANGOLA TELEVISÃO PÚBLICA DE ANGOLA (TPA) Televisão Pública de Angola (TPA) is an Angolan public media company created in 1973. It is based in Luanda. Commissioned to the Italian integrator ARET to develop a TV Van OB for satellite transmission (DSNG). Aret and TPA entrusted AEQ with the supply of the intercom system. EGYPT WAHSH SERVICES FREE The company has acquired for a TV stations in Egypt, two TB 3000 intercom matrix with 12 ports, the first unit in 2014 with CCU concentrator and TP3016 user panels, and the second one in 2016 with CCU concentrator and 4000
    [Show full text]
  • Wired Communications Brochure
    PRODUCT BROCHURE Wired Communications Analog Partyline Intercom Digital Network Partyline Intercom Connectivity Solutions Intercom Accessories About Intercom Technology An intercom (intercommunication system) is a standalone, closed-circuit system for one-way “simplex” and/or two-way “duplex” communication. The general purpose of a professional intercom system is to facilitate simple to complex communication setups for few to thousands of users who need to be continuously on talk and/or listen mode. Two-way communications systems can operate in half-duplex or full-duplex. With half-duplex systems, one party talks while the other party listens. With full-duplex systems, both parties can talk and listen at the same time as if they are in a natural conversation in person. Users who have different roles in a particular operation can be in a conference or partyline together. Or they can be sub-divided into a matrix of independent groups in any one or many private intercom channels. In addition to establishing communication points, an intercom system can also be interfaced with third-party devices such as 2-way radios, 4-wire audios, telephone, TV cameras, AES3 digital audio, relay control (for signal light activation or door control), etc. The core technology of an intercom system could be based on one of the following platforms: 2-wire/analog, 4-wire digital, wireless, or IP networks. The decision to deploy one platform over the other will greatly depend on requirements, environment and budget. These intercom platforms operate independently or can be linked to form a larger system in order to meet specific unique communication workflow needs.
    [Show full text]