ON THE PROJECT, ON THE SHELF, ON THE JOB

INTRODUCING THE NEW MINI INVERTERS BY EMERGI-LITE

RELIABILITY THROUGH TECHNOLOGY WITH TODAY’S HIGHLY EFFICIENT LED TECHNOLOGY, MINI INVERTERS ARE A RELIABLE, ECONOMICAL, HIGH-PERFORMANCE CHOICE FOR EMERGENCY POWER.

Mini Inverters offer many Allows existing fixtures to be used Powers LED fixtures and most light advantages. Provides a broad range as emergency . To preserve sources at 100%. When power fails, of capacity for system flexibility. the aesthetics of high-visibility the Mini Inverter supplies 100% The Mini Inverter provides 125W areas, the Mini Inverter can run power/lumen output with less than to 720W of emergency power existing normally-on light fixtures 1 second of transfer, and is ideal for 90 minutes to exit signs and in a power failure, as an alternative for use with LED fixtures and most emergency lighting equipment. to separate dedicated emergency light sources except HID. Fixtures Each Mini Inverter can power many lighting. can be on, off, switched or dimmed remote fixtures for a streamlined triac dimmable ballast. system with a small footprint. Ideal for locations with limited space to house power systems, Mini Inverters can be installed unobtrusively in a small area and added as needed to provide emergency power on each floor of MINI larger buildings. INVERTERS: EFFICIENT & RELIABLE POWER IN AN EMERGENCY

1 Compatibility with Nexus® real-time monitoring system Reliability is built into the Mini Inverter. The UL924 listed provides even higher levels of system reliability. With the Mini Inverter uses a long-life, maintenance-free the Mini Inverter, all the advantages of Nexus® Lead-Acid battery. Fully-featured self-diagnostics test real-time monitoring system are now available for the batteries and lamps connected to the Mini Inverter inverter-powered systems. Nexus® manages the so you can rest assured that your emergency lighting status of the total load on the Mini Inverter from a system will be on when the main power fails. central control unit. Through wireless communication and building , Nexus runs diagnostics, performs required monthly and annual functional tests according to Life Satefy Code, generates maintenance logs, and runs compliance reports. A Nexus® system can contribute to LEED certification and support initiatives.

RELIABILITY THROUGH TECHNOLOGY

2 Inverter Module MINI INVERTER FEATURES & Terminal Block BENEFITS

Charger Board

Charger Long-life Maintenance free Step up Lead-Acid Battery Transformer

CHOOSING THE RIGHT BACKUP CHOOSING THE RIGHT POWERBACKUP SYSTEM CHOOSINGPOWER THE SYSTEMRIGHT BACKUP POWER SYSTEM

Back-up power can be provided in many ways. However, even though certain methods are suitable for critical applications, they may not be suitable for Emergency Lighting. This is because an Emergency Lighting system has unique load characteristics. Since Emergency Lighting is a critical life safety installation, it must be designed with its specific load characteristics in mind. Mini Inverter systems are specifically designed to provide emergency power for Emergency Lighting systems in a power failure. 3 MINI INVERTER FEATU MINI INVERTER MINIFEATURES INVERTER & FEATURES BENEFITS & BENEFITS

FEATURES BENEFITS Self-Diagnostics/Self-Testing Code Compliance The diagnostic/charger is a fully self-contained, fully Reduces testing/service time for a minimal maintenance automatic microcontroller- based system. Any fault cost, while ensuring that local safety codes are met, and condition causes a status LED indicator to blink, provides system reliability in a power failure condition. identifying the nature of the fault. Every 30 days, the sequence generator will generate a command to force High Performance a transfer in emergency mode for a variable test period The Mini Inverter is a rugged, easy-to-maintain system with based on code requirements (30 seconds each month, exceptional performance for emergency lighting use. It offers and 90 minutes after 12 months). exceptional overload performance without the need to over- specify the rating. System Design Inverter and charger modules utilize highly reliable solid Versatile Applications state electronics.The modules feature input and output Mini Inverter systems can be used in almost every type protection, and they measure and limit their own current. of building, and are ideal for architecturally sensitive applications or when maintenance costs and testing Capacity of individual unit equipment becomes significant. The Capacity is available starting at 125W up to 720W, 120V and smaller unit size of the Mini Inverter allows more flexibility 277V and minimizes testing. The Mini Inverter can be installed at a distance, offering the opportunity to hide the unit True Sine Waveform (250W and up) from view and maintain the architectural design by Using a solid-state, pulse width modulation (PWM) powering normally-on luminaires. inverter, Mini Inverter systems produce pure sinusoidal output waveform with less than 5% Total Harmonic Maximum Light Output Distortion (THD) for linear loads. The Mini Inverter will deliver 100% power / lumen output CHOOSING THE RIGHT BACKUP of the fixture up to the specified run time. It is compatible Nexus Monitoring System with all fluorescent ballast, LED drivers or incandescent The Mini Inverter is compatible with Nexus®, a real-time light sources. POWER SYSTEM monitoring system that manages the status of the total load on the Mini Inverter from a central control unit. Reliability Through Technology ® Nexus® runs diagnostics, performs required monthly and Nexus allows for maintenance time and cost savings, annual functional tests as per Life Safety Code, generates and ensures that the emergency lighting fixtures will ® maintenance logs and runs compliance reports. perform when needed. Nexus can contribute to LEED certification and support sustainability objectives.

4 TYPE: TYPE: CATALOG #: CATALOG #:

NOTES: NOTES:

Mini-InverterMini Inverter Series Series SYSTEMS InterruptibleInterruptible Unit Equipment Unit Equipment CENTRAL & INVERTER CENTRAL & INVERTER SYSTEMS HighlightsHighlights SuggestedSuggested Specification Specification The Mini-InverterThe Mini is Inverter a UL Listed is a ULstand-alone Listed stand-alone pure sine wavepure sine(250W wave (250WEmergency Emergency lighting shall lighting be providedshall be byprovided inverter by unit inverter equipment unit equipment and up) outputand up) inverter output designed inverter designedto provide to power provide to powerdesignated to designated designed todesigned operate designatedto operate incandescent,designated incandescent,fluorescent and fluorescent LED and emergencyemergency lighting fixtures. lighting Infixtures. a power In loss a power situation, loss it situation, will supply it will fixturessupply on LEDemergency fixtures power on emergencyat their full nominalpower lumenat their rating full nominalduring the lumen rating power frompower the onboard from the battery onboard supply. battery supply. full 90 minutesduring emergency the full discharge 90 minutes cycle. emergency System output discharge will be ratedcycle. System at wattsoutput for 90will minutesbe rated and at provide watts used for output 90 minutes connections and provideto fused The Mini-InverterThe Mini works Inverter in conjunction works in conjunction with incandescent, with incandescent, LED, and LED, and the load. Theoutput system’s connections voltage ratingto the shall load. be The system’s VAC input/output. voltage rating shall be fluorescentfluorescent fixture types fixture and types will automatically and will automatically run switched, run normally-switched, normally- The inverter unit shallVAC allowinput/output. for connected The inverter emergency unit shallfixture(s) allow to for be connected on, or normally-offon, or normally-off designated designated emergency emergency fixtures. fixtures. normally-on,emergency normally-off, fixture(s) switched to orbe triacnormally-on, dimmable normally-off, ballasts without switched or triac The Mini-InverterThe Mini isInverter ideal for is applicationsideal for applications requiring anrequiring emergency an emergency affecting lampdimmable operation ballasts during without a power affecting failure. Upon lamp utility operation power loss,during a power source forsource lighting for arrangements lighting arrangements that utilize thatmultiple utilize lamp multiple and fixturelamp and fixturethe inverter failure. unit shall Upon deliver utility 100% power of loss,its rated the outputinverter to unit the shall emergency deliver 100% of its types and typesis available and is in availablesurface mountin surface and comesmount withand acomes three yearwith a 3fixtures year regardlessrated output of the to thelocal emergency or fixtures dimmer regardless position, andof the will local switch warranty andwarranty seven-year and 7 pro-rata year pro-rata battery battery warranty. warranty. provide poweror dimmer to emergency position, andfixtures will provideat distances power ofto upemergency to 1000 fixtures at feet. The housing shall be manufactured using 14-gauge steel with a Detailed warranty terms located at: www.emergi-lite.com/usa/files/EL_Warranty.pdf distances of up to 1000 feet. The housing shall be manufactured using Features white baked-on14-gauge powder (400W coat & paint720W) finish. or 18-Gauge The unit’s (125W electronics & 250W) shall steel with a • Lamps operated:Features Incandescent, LED, fluorescent lamps and ballast include a self-containedwhite baked-on inverter powder section coat with paint a fully finish. automatic, The unit’s thermal- electronics shall compensating variable-rate battery charger, AC lockout feature, low combinations,• Lamps including operated: triac Incandescent, dimmable ballasts LED, (consult fluorescent factory lamps if and ballast include a self-contained inverter section with a fully automatic, thermal- 0-10V or DALI dimming) voltage batterycompensating disconnect, variable-rate DC overload, battery short charger, circuit and AC brownoutlockout feature, low combinations, including triac dimmable ballasts (consult factoryprotection if as standard. The unit shall utilize a sealed Lead-Acid battery • Components:DALI High-efficiency dimming) pure sine wave inverter (250W and up), voltage battery disconnect, DC overload, short circuit and brownout -compensated charger 12V oversized Valve Regulated with a 10-year design life. The inverter system shall be UL 924 Listed • Components: High-efficiency pure sine wave inverter (250W and up), protection as standard. The unit shall utilize a sealed Lead-Acid battery Lead-Acid (VRLA) battery and labeled.with The a unit10-year shall designbe covered life. The under inverter a 3-year system warranty shall onbe theUL 924 Listed temperature-compensated charger, 12V oversized Valve Regulatedelectronics and battery and a 7-year pro-rata warranty on the battery. • Construction:Lead-Acid 14-gauge (VRLA) steel battery housing and labeled. The unit shall be covered under a 3-year warranty on the electronics and battery and a 7-year pro-rata warranty on the battery. • Emergency• Construction: lighting supplied 14-gauge from one (400W convenient & 720W) source or 18-Gauge (125W & Specifications • Input/Output250W) voltage steel 120V housing 60 Hz or 277V 60 Hz Transfer TimeSpecifications less than 1 second • Replacable• Emergency output fuse lighting protection supplied from one convenient source • Line voltage• Input/Output allows for remote voltage mounting 120V 60 ofHz emergency or 277V 60 fixtures Hz at Voltage RegulationTransfer on Time Emergency +/- 3% less than 1 second distances up to 1000 feet • Replacable output fuse protection Frequency RegulationVoltage Regulation on Emergency on Emergency60 Hz +/- 1%+/- 3% • Low Voltage Battery Disconnect • Line voltage allows for remote mounting of emergency fixtures at Load Power FrequencyFactor Range Regulation on Emergency.9 leading to .960 lagging Hz +/- 1% • Unit comesdistances standard up with to electronic1000 feet lockout and brownout circuits • Meets or• exceeds Low Voltage all National Battery Electrical Disconnect Code and Life Safety Code Operating Temperature 68° to 86°F (20°• 250W to 30°C) model: 0.9 leading Emergency Lighting Requirements UL924 Listed to 0.9 lagging • Unit comes standard with electronic lockout and brownout circuits Load Power Factor Range • Cabinet in factory white semi-gloss powder-coat paint finish Warranty • 125, 400 & 720W models: • Meets or exceeds all National Electrical Code and Life Safety Code ® 0.8 leading to 0.8 lagging • May acceptEmergency load to its Lightingfull capacity Requirements when load UL924feature Listedpower factor All Emergi-Lite inverter products receive 100% quality inspection of 0.9 or more before shipment to insure proper and satisfactory operation. • Cabinet in factory white semi-gloss powder-coat paint finish Operating Temperature 68° to 86°F (20° to 30°C) • Standard auto-diagnostic, non-audible, Nexus® system interface When operated under normal conditions, Emergi-Lite® inverter • May accept load to its full capacity when load feature power factor optional with an improved minimum load lost detection products will provide years of dependable service. This unit is backed of 0.9 for 250W model and 0.8 for 125, 400 and 720W model Warranty of 10% by a 3/7 year warranty. The unit is covered by a complete 3-year ® ® • Standard auto-diagnostic, non-audible, Nexus system interfacewarranty againstAll Emergi-Lite defects in inverter material products or workmanship, receive 100% and quality a 7-year inspection optional with an improved minimum load lost detection of 10% pro-rata batterybefore warranty. shipment to insure proper and satisfactory operation. ® • Standard lighting control override for 0-10V dimming systems The inverterWhen unit shall operated be Emergi-Lite under normal® model: conditions, Emergi-Lite inverter products will provide years of dependable service. The unit is Replacement Battery covered by a complete 3-year warranty against defects in material or workmanship, and a 7-year pro-rata battery warranty. EMIU-125 860.0024-E The inverter unit shall be Emergi-Lite® model: . EMIU-250 2X 860.0024-E EMIU-400 2X 860.0043-E EMIU-720 2X 860.0096-E

124 5 118 TYPE: CENTRAL & INVERTER SYSTEMS TYPE:

CATALOG #: CENTRAL & INVERTER CATALOG #:

NOTES: NOTES: SYSTEMS

Interruptible Unit EquipmentMini-Inverter 125W, 250W, 400W Series or 720W Standard with Non-AudibleInterruptible Advanced Unit Equipment Diagnostics Circuitry & Lighting Control Override

NEW! NEW!

ElectricalElectrical Characteristics Characteristics & Dimensions & Dimensions NOTE: For wiringNOTE: diagram, For wiring please diagram, refer to please the specification refer to the specificationsheets. sheets. PoWEr CABINET DIMENSIONSCaBinEt DiMEnSionS TOTAL WEIGHTWEigWEIGHTHt W/OWE BATTERYigHt W/o BattErY POWER SinE WavE inStaLLation no. oF BattErY ratingSINE WAVE INSTALLATION NO. OF BATTERY RATING W” H”W” D”H” D” 120V & 277V120v & 277120Vv & 277V120v & 277v 125W 125WModified ModifiedT-Bar T-Bar 24” 6.5”24” 8”6.5” 1 8” 1 50 lbs 43 lbs 22 lbs 20 lbs 125W 125WModified ModifiedWall Wall 16.5” 12.2”16.5” 7.3”12.2” 1 7.3” 1 50 lbs 41 lbs 22 lbs 18.5 lbs 250W 250WPure PureWall Wall 27” 12.2”27” 7.3”12.2” 2 7.3” 2 100 lbs 76 lbs 45 lbs 30 lbs 400W 400WPure PureWall Wall 24” 10.5”24” 20”10.5” 2 20” 2 150 lbs 128 lbs65 lbs 50 lbs 720W 720WPure PureWall Wall 24” 14.5”24” 20”14.5” 2 20” 2 220 lbs 185 lbs95 lbs 72 lbs

Power ConsumptionPower Consumption And Unit a Ratingnd Unit rating EMErgEnCY PoWEr avaiLaBLE For LoaD MoDEL nUMBEr aC SPECS EMERGENCY POWER AVAILABLE FOR LOAD MODEL NUMBER AC SPECS 90 Min 2H 3H 4H 90 MIN 2H 3H 4H EMIU-125 1.15 / 0.50 Amps 125W 83W 62W 47W EMIU-125 EMIU-250 1.15 / 0.70 Amps2.28 / 0.99 Amps 125W 250W 83W 167W 62W 125W 47W 94W EMIU-250 120/277VAC2.75 / 1.20 Amps 250W 167W 125W 94W EMIU-400 120/277VAC 3.73 / 1.62 Amps 400W 300W 200W 150W EMIU-400 EMIU-720 4.60 / 2.00 Amps6.90 / 2.99 Amps 400W 720W 300W 480W 200W 360W 150W 270W EMIU-720 9.60 / 4.00 Amps 720W 480W 360W 270W How to order How to Order SEriES CaPaCitY voLtagE oPtionS SERIES CAPACITY VOLTAGE DIAGNOSTIC FEATURE OPTIONS EMIU -125= 125W BLANK= 120/120VAC or 277/277VAC -NEX= Nexus® wired EMIU -125= 125W BLANK= 120/120VAC-250 or= 277/277VAC250W -Blank= Advanced-Diagnostic, non-audible* -NEXRF-D1= Time= Nexus Delay® wireless (5 minutes) -250= 250W -400= 400W -AD= Advanced-Diagnostic, audible* -D3-D2= =Time Time Delay Delay (15 (10 minutes) minutes) -400= 400W -720= 720W -NEX= Nexus® wired -T-D3= Recessed= Time Delay T-Bar (15 mounting minutes) (125W unit only) -720= 720W -NEXRF= Nexus® wireless -AD-SAC= Advanced-Diagnostic,= Service Alarm Contact* audible* -SAC-T== Recessed Service Alarm T-Bar Contact** mounting -10V=(125W Lighting unit control only) override for 0-10V dimming system***

* Service alarm contact (SAC) shall provide a * Minimum24V loadsignal, required: the charger 10% of board unit capacity will indicate ** Not availablea fault by with choosing 720 capacity a contact. Not available * Minimum load required: 10% of unit capacity *** For withany other 720 lightingcapacity , please consult factory. Example: EMIU-720 Note: The unit comes standard with Advanced Diagnostic (non-audible) Example: EMIU-720

125 119 6 ON THE PROJECT, ON THE SHELF, ON THE JOB

www.emergi-lite.com

All information and specifications contained in this flyer are subject to change due to engineer design, errors and omissions. Illustrations and diagrams within this flyer may vary from actual products.