THE ORIGINAL DENSIFICATION TECHNOLOGY DENSIFY

CHEERS TO SEVENTY YEARS!

ZALANDO LODZ, POLAND by FIBRE SYSTEM Sp. z o.o. 2012

Think concrete’s tough? We make it tougher.

ASHFORDFORMULA.COM 801.489.5663 / 800.998.5664 Ashford Formula is a chemically reactive liquid that penetrates the concrete, solidifying the concrete surface components into a solid mass. It produces a permanently denser, harder, penetration and abrasion- resistant concrete surface. Ashford Formula is inorganic, non- toxic, VOC free, colorless and odorless.

Ashford Formula densifies concrete Ashford Formula chemically hardens PROLOGIS PARK surfaces into a solid mass by the concrete surface, increasing the SAITAMA, JAPAN penetrating the concrete and by COSMO TRADE abrasion resistance by 32%. 2015 chemically filling the pores from within. THE RIGHT DECISION NOW, AND FOR THE FUTURE ABRASION DENSIFIES RESISTANCE There are so many choices and so many reasons, but the decision is simple. An Ashford Formula treated floor simply out-performs the competition in results and long-term cost savings, with an economical one-time investment. Properly densifying your floor means doing the job right the first time for results that last a lifetime. Ashford Formula combines with Ashford Formula reacts immediately, calcium hydroxide, becoming an chemically stabilizing the finished integral part of the concrete, thus concrete surface. It also accelerates SUBSTANTIAL REDUCED CERTIFICATIONS completely dustproofing the surface. and enhances hydration of the This reduces maintenance costs and COST SAVINGS ENVIRONMENTAL IMPACT & RECOGNITIONS portland , helping the concrete protects inventory and equipment from reach its design properties. concrete dust. Proven long-term performance at Use of existing concrete floors as the TÜV SŰD TM 14 Tested and DUSTPROOFS CURES minimal cost finished surface Certified

Permanent life cycle - no need for Over time, Ashford Formula treated Application of the Ashford Formula is a Single, permanent application - no Zero (0) VOCs replacement like floor coverings floors will develop apermanent and one-time, permanent application. This need for expensive re-application attractive sheen. Rather than eroding eliminates the need for expensive materials, labor or costly facility CE Declaration of Conformity with traffic, the floor surface actually re-application materials, labor costs downtime Produces no fumes, vapors, off-gassing; begins to self polish. Note: Open or and facility downtime. Routine surface VOC free - improves indoor air quality porous surfaces, or floors with poor surface cleaning is all that is required for long- REACH Certified PERMANENT integrity may not achieve these results. ELIMINATES HIGH term maintenance. Quick application - saves valuable SHEEN MAINTENANCE COSTS Contributes to LEED points for construction time and cost NFSI Certified “High-Traction” sustainable building; HPD available

Approved for use in DENSIFY FOR STRONGER, TOUGHER CONCRETE FLOORS Eliminates high maintenance costs - Packaged in re-conditioned blue drums only routine cleaning is required for food handling facilities For years, concrete floors were protected with films and coatings - merely temporary solutions which wear away and require re-application. Ashford optimum results Formula takes a different approach by penetrating the concrete surface, growing crystals in the concrete itself. This reaction fills the natural pores and voids in the concrete, densifying the surface internally.

I AM CONVINCED THAT THE ASHFORD

x2500 x2500 FORMULA IS THE ONLY WAY TO GO, AND I DON’T HESITATE TO GIVE THE FORMULA AN UNQUALIFIED RECOMMENDATION. NON-DENSIFIED CONCRETE ASHFORD FORMULA DENSIFIED CONCRETE

A simple scratch test with a metal This non-densified concrete Scratching a concrete surface Ashford Formula densifies by J. Keith McCoy, Chief of Maintenance, Pennzoil Company object demonstrates the softness of sample reveals the porous densified with Ashford Formula penetrating the concrete surface and PENNZOIL EXECUTIVE HANGAR non-densified concrete. structure of concrete, which leads reveals no erosion or dusting. filling the natural pores and voids HOUSTON, TX, USA to wear and deterioration. Ashford Formula has strengthened with crystalline growth. 1980 the concrete surface from within. 1 3 4

REAL PROJECT HIGHLIGHTS INDUSTRIES SERVED Otis Offices 1 LEGO 2 Bugatti 3 by eMZet SRO - CZECH REPUBLIC by NORSA GmbH - GERMANY by ERA Ltd. - TURKEY > Correctional Facilities > Exhibit Halls > Parking Decks / Garages > Warehouses

4 Parking Garage 5 Costco 6 Post Cereal > Data Centers > Manufacturing Plants > Retail Stores by Ashford Formula de Mexico - MEXICO by Gia Phu Dinh Construction - VIETNAM by Philip E. Bath, Inc. - USA > Distribution Centers > Outdoor Concrete > Stadiums / Sports Arenas

7 China Tobacco Distribution Center 8 Melbourne Market Relocation Note: This is not a comprehensive list. Ashford Formula and Curecrete’s line of supporting products can be used on most any concrete floor serving a multitude of industries and functions. by Wuxi Hua Can Chemical - CHINA by Green Concrete Products - Australia

8

5 6 7 With its one-time application, the Ashford Formula never requires re-treatment. It provides exceptional performance for the entire life of your floor. Never halt your business productivity or pay for costly repeated applications down the road. It’s why notable worldwide Your concrete floor is more than a building foundation. It is also the corporations have chosen the performance of the Ashford Formula. foundation of your business productivity. For lifelong floor performance, long-term cost effectiveness and sustainability, worldwide corporations With the longest proven track record of performance in the industry, like Caterpillar, CocaCola, DHL, Procter & Gamble, IKEA and Whirlpool over 70 years, Ashford Formula is the trusted product for permanent, A SOLID FOUNDATION, FROM THE GROUND UP have chosen Ashford Formula as their concrete densifier of choice. superior concrete floor results. Your business productivity requires a solid, DENSIFIED concrete floor. PERFORMANCE CRITERIA

PRODUCT INFO

0.7 0.7 0.7 0.7

FERRO TORRE SA BONDING 0.6 0.6 0.6 GUAYAQUIL, ECUADOR 0.6 nce ista U ASTM D 3359 - Surface Adhesion by SEPISA CORP es A N R S 2017 n H T 0.5 0.5 0.5 0.5 io F R s O E a Adhesion of Coatings: r R A b

D T A

E 0.4 0.4 0.4 0.4 For epoxy, a 22% increase in adhesion

d

F

D

e

O

s +

S over untreated samples. No change in

a

32.5% R A

e

M r

c

M 0.3 0.3 0.3 0.3 adhesion for polyurethane. U

n

I

P

L

=

A

L

r

a

E

e

W

s s e L 0.2 0.2 0.2 0.2 PERMEABILITY 0.1 0.1 0.1 0.1 DESCRIPTION SURFACE PREPARATION PAINTING Seepage Rate Clear, odorless, non-toxic, non-combustible, • Freshly Finished Concrete (NEW): Allow at least seven (7) drying days before MIN AF non-flammable. Contains no VOCs. applying paint on existing concrete. INCREASED MIN AF Using a 7 ft. (2.13 m) head of No preparation required. SCOF SCOF DCOF DCOF ABRASION RESISTANCE water on a 4.91 in2 (124.71 mm2) • Existing Concrete (OLD): Allow twenty-eight (28) days for proper curing USES WET WET area treated with Ashford Formula Sweep, scrub or strip concrete to before painting new concrete. only allowed a rate of 0.00073 oz Concrete, heavyweight concrete block, remove any surface contaminants ASTM C 779 - Depth of Wear (0.022 cc) / hour. After several days exposed aggregate and other sand/aggregate NOTES or film. HIGHER FRICTION the sample became damp, but no combinations. Abrasion Resistance to Revolving Disks: Apply to colored concrete only after the slab observable local seepage. An improvement of 32.5% over New or old concrete, rough or smooth surfaces. APPLICATION is fully cured, unless installed by a factory certified applicator. untreated samples after 30 minutes. Only one permanent application is required. ANSI / NFSI B101.1-2009 & Apply with high-volume, low-pressure sprayer ANSI / NFSI B101.3-2012 Do not allow to dry on finished surfaces FUNCTIONS until flood coat is achieved. Work material WEATHERING (glass, aluminum, stainless steel, walls, etc.) as into the surface with fine-bristled brooms, Static Coefficient of Friction (SCOF) and Dynamic Densifies, dustproofs, hardens and cures. permanent etching may occur. Any spills on or with an auto scrubber. Keep the entire ASTM G 23 - Light Exposure Protects against dusting, pitting, spalling, these surfaces should be removed while the Coefficient of Friction (DCOF) minimum surface wet with Ashford Formula for 30 9 9 9 Degradation efflorescence and surface crazing. Inhibits Ashford Formula is still in liquid form. standards vs. Ashford Formula: minutes. Then when the Ashford Formula freeze/thaw deterioration. SCOF - 0.60 vs. 0.67 // DCOF - 0.42 vs. 0.54 becomes slippery, flush completely with water 8 8 8 Exposure to ultraviolet light and water: The Ashford Formula may not prevent and squeegee dry or vacuum excess with an deterioration of floor slabs on which salts from No evidence of adverse effects on the PACKAGING automatic scrubber. ice melt are allowed to accumulate, especially 7 7 7 samples treated with Ashford Formula. • 55 - gallon drums / 208 liters when the floor is exposed to frequent wet/ *See Spec Data Sheet or Application dry cycles. Regular and frequent cleaning 6 6 6 • 5 - gallon pails / 19 liters Specifications for specific details. of all slabs exposed to road salts is critical to preventing salt-related damage. VOC EMISSION TEST DRYING TIME 5 5 5 STORAGE LIFE COMPLIANCE Although the Ashford Formula provides a Indefinite. Agitate before use. One (1) to three (3) hours. The surface may 4 4 4 dense concrete surface, it cannot in all cases be used as soon as the application is complete California Dept of Public Health and the surface is dry to the touch. Newly prevent the migration of moisture vapor from 3 3 3 CDPH / EHLB / Standard Method COVERAGE placed concrete requires the normal hardening beneath a floor slab. In conditions of high period. vapor drive, salts and other inorganics may Version 1.2, 2017 2 2 U A Approximately 200 ft /gal (5 m /L). still be deposited on concrete floor surfaces 2 2 2 N S T H R F treated with the Ashford Formula, especially E O Indoor air quality compliant. A SURFACE APPEARANCE R Coverage may depend on the temperature and T when no vapor barrier has been installed D 1 1 1 E Certificate and test results available

D

porosity of the concrete. F

beneath the slab. O

On smooth troweled concrete, a sheen +

13.3% S upon request.

R

A

M

develops within 6-12 months. All other M

U P

L

Ashford Formula is a highly effective L

surfaces retain their natural appearance. E TEMPERATURE LIMITS A AF H O C3O9 The sheen can be accelerated by burnishing compound which delivers superior results. 2 Apply in temperatures up to 115°F (46°C) the floor. A spiff coat can also be used to Application should be performed by qualified ELECTRICAL RESISTANCE or as low as 35°F (1.7°C) and protect from enhance the initial sheen. contractors with a clear understanding of its OF DISSIPATIVE RESILIENT freezing for a period of six (6) days. application and uses. *See Spec Data Sheet FLOORING EQUIPMENT CLEAN-UP or Application Specifications for specific ENHANCED CURING details. GREATER Use soap and water before the Ashford Formula ASTM F150 - Standard Test IMPACT RESISTANCE QUICK LINKS dries. ASTM C 856 - Petrographic Method for Electrical Resistance Examination (Density of the Paste) of Conductive & Static ASTM C 805 - Rebound Number Dissipative Resilient Flooring The number of unhydrated cement HPD APPLICATION MANU SAFETY SPEC grains remaining on the surface - depth Considered static dissipative. SPECS v2.1 SPEC DATA DATA Impact Resistance by Schmidt Hammer: SHEET of 150 - 250 τµm. Fewer unhydrated An increase of 13.3% over untreated samples. Certificate and test results available (SDS) cement grains mean better curing. upon request.

This technical information is provided as a general performance profile for evaluating the appropriate use of Ashford Formula. Independent laboratories obtained the test performance results under controlled environments. Curecrete Distribution, Inc. makes no claim that these tests, or any other tests, accurately represent actual design and/or usage environments. PROPER MAINTENANCE OPTIMAL PERFORMANCE ...for a lifetime.

MAINTENANCE PROGRAM

An effective maintenance program that includes routine scrubbing with stiff bristle brushes, ample down pressure, and proper amounts of water and cleaner will enhance the floor’s performance significantly. Implementation of the following maintenance program will allow the Ashford Formula to continue to react with the concrete, lifting contaminants away from the concrete and allowing the marble-like sheen to develop.

Scrub Floor OFTEN: Minimum routine cleaning 2 - 3 times per week with CreteClean Plus with Scar Guard provides superior results.

Clean Spills QUICKLY: After densification is complete, concrete will resist contamination and moisture penetration of most liquids. Corrosive or aggressively staining contaminants should be removed quickly to avoid possible staining.

RECOMMENDED SUPPLIES

> Automatic Scrubber > Large Volumes of Water Capable of 125 - 150 lbs. of downward pressure. Water used while cleaning the concrete surface will actually accelerate the reaction between Ashford Formula and the > Medium-Aggressive Nylon Brushes concrete. Accelerates the sheen and creates a more uniform appearance. > Oil Emulsifier & Acrylic Stripper: CreteStrip™ AIRCRAFT HANGAR The TRUTH is... Use directly on stain for spot treatment. BRUNEI How you treat your floor now, determines > Cleaner*: CreteClean Plus with Scar Guard™ by BUE BRUNEI 2014 Performance enhancing cleaner specifically designed > Polypropylene or Stiff-Poly Brushes how your floor will treat you down the road. to clean densified and densified- floors. Regular maintenance after sheen develops. Regular use helps decrease the visibility of minor scratches and blemishes and helps maintain the concrete sheen. *If other cleaners are used they should be non-acidic and void of hydroxides and sulfates. LIFELONG, OPTIMAL PERFORMANCE

Cleaning your Ashford Formula floor is convenient, economical and will result in a floor that has a marble-like sheen that improves with age. With RECOMMENDED PRODUCTS Ashford Formula, there is no surface film or coating present to peel, blister or require expensive replacement and repeated applications. The floor’s OIL EMULSIFIER & performance, as well as the satin sheen that develops over time, is enhanced by proper cleaning and maintenance. Following a proper maintenance CLEANER: ACRYLIC STRIPPER: SALT PROTECTION: program as outlined here will ensure optimal floor performance for a lifetime.

SINGLE EXPECTATIONS FROM A PROPERLY MAINTAINED FLOOR DOSE IMMEDIATELY AFTER TREATMENT • 5 gal. (19 L) pails • 5 gal. (19 L) pails • Single dose packaging for auto • 5 gal. (19 L) pails • 55 gal. (208 L) drums The hardening and dustproofing will take effect within the normal curing period on new concrete and within 24-48 hours on existing • 55 gal. (208 L) drums scrubbers and mop and bucket • 55 gal. (208 L) drums concrete. The floor will have a normal concrete appearance or a slight sheen (broom-finished or rough-textured concrete will cleaning retain its natural concrete appearance). CASE STUDY: NORTH POINT TOYOTA The density and hardness of the floor will be immediately enhanced. However, care should be taken not to gouge the floor with nails, etc. after the initial placement.

To accelerate the sheen, the floor can be burnished with a high speed propane burnisher and a black stripping pad at 1800 to 3000 RPMs, or cleaned daily using an auto-scrubber equipped with medium-aggressive nylon brushes. A spiff coat can also be done to enhance the initial sheen. The use of truck soap had caused this floor to have a dull 3-6 MONTHS AFTER TREATMENT appearance. After a proper maintenance program was If the standard maintenance program is followed, smooth-troweled floor surfaces will develop a sheen. implemented, the natural sheen Note: A sheen will not develop on floors with an open, porous finish, or on floors with a broom finish. from the Ashford Formula was once again visible. On steel-troweled floors, water typically begins to bead on the surface. NORTH POINT TOYOTA 12 MONTHS AFTER TREATMENT LITTLE ROCK, AR, USA by ROBERTS-MCNUTT, INC. A hard shell-finished surface will develop. 2007 Surface is resistant to oil penetration and moisture contamination. See how our “One Complete System” of concrete floor products works together to enhance the performance of your concrete floors.

ONE COMPLETE SYSTEM FOR ALL YOUR DENSIFIED AND DENSIFIED-POLISHED CONCRETE FLOORING NEEDS PREPARE FILL REPAIR DENSIFY DENSIFY-POLISH PROTECT CLEAN + MAINTAIN Product availability varies by market. Contact your local representative.

ONE EXPERT SOURCE THE DIFFERENCE

QUALITY + “GREEN” BY DESIGN A quality floor, paired with quality products, equals superior flooring results. 7O+ YEARS OF LIVING The Ashford Formula and the concept of concrete Let our products take your floor to the next level. PROOF THAT FROM THE VERY densification was “green” well before going “green” 70 ever became a movement. The permanent effects of this YEARS ABSOLUTELY CAN’T BEGINNING unique combination will save significant time, money and PERFORMANCE BE DISPUTED energy in the long term. From start to “finish,” our One Complete System of concrete floor products outperforms the competition and will enhance your concrete floors’ Whether old or new The Ashford Formula’s green qualities make it an exceptional choice for today’s sustainable and green performance durability, longevity and appearance. concrete, our products building initiatives. It has been widely specified for use on projects that have garnered LEED Certified, will enhance your floor’s LEED Silver, LEED Gold and LEED Platinum status. VALUE performance, ensuring its durability and longevity for SUSTAINABILITY BENEFITS Your floors, done right, and done once, will save you time and money in a lifetime. LEED PLATINUM the long term. Products that don’t perform, and which require repeat 1 Energy Cost Savings applications, hamper your business’ productivity and bottom line. The John and Frances 2 Reduce Life Cycle Impacts Angelos Law Center

University of Baltimore 3 No Off-Gassing

Built in 1949, the Casa de Cadillac dealership in Sherman Oaks, CA, USA is one of the earliest by Cuviello Concrete 4 Improved Thermal Comfort THE “ORIGINAL” documented floors treated with the Ashford Formula. This facility is on the California historical

CONCRETE DENSIFER register. Still in use today, the concrete floor has provided more than six decades of continuous 2O12 5 Increased Daylighting; service and attests to the longevity and durability of the Ashford Formula. Light Reflection

As if 70+ years isn’t proof enough of the Ashford CURECRETE - Formula’s enduring performance, Curecrete SETTING THE Distribution, Inc. offers a standard 20-Year YEARS 20 Product Performance Warranty on Ashford STANDARD, OR Formula floors, as well as aLifetime* Product RAISING THE LIFETIME Performance Warranty - the longest warranty PRODUCT PERFORMANCE WARRANTY offered in the industry - when maintained with BAR CreteClean Plus with Scar Guard™.

1989 2OO9 *Qualifying conditions apply. Curecrete Distribution, Inc. has been providing leadership in the concrete densification industry for more than 70 years. Curecrete continues to lead with an unwaivering commitment to superior products, best practices and industry expertise.

CONTACT 1203 Spring Creek Place TECHNICAL INFO (801) 489-5663 Springville, UT 84663, USA (800) 998-5664 (801) 489-5663 [email protected] (800) 998-5664 www.ashfordformula.com www.curecrete.com

CUSTOMER (801) 489-5663 REPRESENTATIVES & Ashford Formula is sold through a network of SERVICE (800) 998-5664 INTERNATIONAL manufacturer representatives and international distributors. To contact your representative or [email protected] DISTRIBUTORS distributor, please visit: www.ashfordformula.com/reps

CHEWY.COM FULFILLMENT CENTER GOODYEAR, AZ, USA by BUILDING SOLUTIONS 2017 Copyright 2018 Phoenix Business Journal

A SOLID FOUNDATION, FROM THE GROUND UP Because your business productivity requires a solid, DENSIFIED concrete floor.

Ashford Formula - Main Brochure RV 6-12-2019