BEN TAUB HOSPITAL BRONCHOSCOPY SUITE RENOVATION

1504 Taub Loop. Houston.

JOHNSTON 2603 Augusta Drive, Suite 1500 Houston. Texas 77057 T 713.244.8300 F 713.532.9006 www.johnston-llc.com

13 July 2018

Harris county hospital district SIGNAGE & WAYFIDNING MASTER PLAN

UPDATED MASTER PLAN DRAWINGS, SPECIFICATIONS AND INSTALL NOTES 6 DECEMBER 2010 TABLE OF CONTENTS Section i

SECTION 1: Introduction Introduction ...... 1.1 Design Criteria...... 1.3 How To Use This Manual ...... 1.4

SECTION 2: How To Use This System Concept ...... 2.1 Manual Definition of Terms ...... 2.2 Wayfinding Analysis...... 2.3 Wayfinding Concept ...... 2.4

SECTION 3: Construction Sign Placement ...... 3.1 Standards Standard Mounting Locations ...... 3.2 Construction Standards...... 3.3 Material Specifications...... 3.13

SECTION 4: Graphic Standards Color Standards ...... 4.1 Font Standards ...... 4.2 Typography Standards ...... 4.3 Symbol Standards ...... 4.4 Drawing Notation Standards ...... 4.5

EXT.01.2C Monument Sign Vertical, SECTION 5: Exterior Signs Metallic Silver-Grey...... 5.1 EXT.03.2 Wall-Mounted Letters, White ...... 5.3 EXT.04 Vehicular Directional ...... 5.5 EXT.013 Glass Canopy Identity ...... 5.8 INT.01.1 Directory, Large...... 6.1 INT.01.2 Directory, Small ...... 6.8 SECTION 6: Interior Signs INT.03.1 Overhead Destination, Large ...... 6.15 INT.03.2 Overhead Destination, Small ...... 6.18 INT.03.3 Overhead Destination, Large -- Aluminum Letterforms...... 6.21 INT.04.1 Destination, Large...... 6.23 UPDATED AUGUST 2016 INT.04.2 Destination, Small ...... 6.26 INT.05 Identity, Overhead ...... 6.30 INT.06 Elevator Identity, Wall-Mounted...... 6.32 INT.07.1 Wall Directional, Large...... 6.36 INT.07.2 Wall Directional, Medium...... 6.40 INT.07.3 Wall Directional, Small ...... 6.44 INT.08.1 Overhead Directional, 1-Line Suspended 6.47 INT.08.2 Overhead Directional, 1-Line Wall-Mounted...... 6.50 INT.08.3 Overhead Directional, 2-Line Suspended...... 6.53 INT.08.5 Overhead Directional, 2-Line Wall Mounted -- Aluminum Letterforms 6.56

WESTLAND SPECIALITY CLINIC PACKAGE 3: DESIGN DEVELOPMENT Page i TABLE OF CONTENTS Section i

SECTION 6: UPDATED AUGUST 2016 INT.09.1 Typical Room Identity, Wall ...... 6.58 Interior Signs UPDATED AUGUST 2016 INT.09.2 Typical Room Identity, Glass...... 6.60A (continued) UPDATED AUGUST 2016 INT.09.3 Typical Room Identity, Large...... 6.60C UPDATED AUGUST 2016 INT.10.1 Changeable Room Identity, Wall ...... 6.61 UPDATED AUGUST 2016 INT.10.2 Changeable Room Identity, Glass..... 6.62A UPDATED AUGUST 2016 INT.11 Typical Room Identity With “In Use”... . 6.64 UPDATED AUGUST 2016 INT.13.1 Restroom Identity...... 6.67 UPDATED AUGUST 2016 INT.13.2 Changeable Room Identity, Glass..... 6.69A INT.14 Workstation Identity ...... 6.70 INT.16.1 Elevator Call Button Map...... 6.72 INT.16.2 ...... 6.75 UPDATED AUGUST 2016 INT.17 Stair Corridor Identity ...... 6.78 UPDATED AUGUST 2016 INT.18 Stairwell Identity ...... 6.81 INT.19.1 Notice Posting, Extra-Large ...... 6.84 INT.19.2 Notice Posting, Large...... 6.88 INT.19.3 Notice Posting, Medium...... 6.91 INT.19.4 Notice Posting, Small ...... 6.94 UPDATED AUGUST 2016 INT.19.5 Notice Posting, Glass Door Vinyl ..... 6.96A UPDATED AUGUST 2016 INT.20.1 Overhead Cubicle Identity ...... 6.97 INT.20.2 Wall Cubicle Identity ...... 6.100 INT.21.1 Handgun Regulations, Glass ...... 6.104 INT.21.3 No Smoking Regulations, Glass ...... 6.106 INT.21.4 No Smoking Regulations, Wall-Mounted ...... 6.108 UPDATED AUGUST 2016 INT.22.1 Insert Holder, Evacuation. Map, 8.5X11 ..... 6.110 UPDATED AUGUST 2016 INT.22.2 Insert Holder, 8.5X11...... 6.112A INT.23 Entrance Glass Graphics ...... 6.113 UPDATED AUGUST 2016 INT.25 Welcome Identity ...... 6.115 INT.26 Department Identity...... 6.117

SECTION 7: Garage Signs GAR.01.1 Garage Entrance Identity, Large ...... 6.119 GAR.01.2 Garage Entrance Identity, Small...... 7.2 GAR.02 Clearance Identity...... 7.3 GAR.03.1 Overhead Directional, Large...... 7.4 GAR.03.2 Overhead Directional, Small ...... 7.5 GAR.03.3 Overhead Directional, Wall Mounted . . . 7.6 GAR.04 Level Identity ...... 7.7 GAR.05 Elevator Call Button Map...... 7.8 GAR.06 Stair Corridor Identity ...... 7.11 GAR.07 Stairwell Identity ...... 7.14 GAR.08 Typical Room Identity ...... 7.17 GAR.09 ADA Parking Identity ...... 7.18

WESTLAND SPECIALITY CLINIC PACKAGE 3: DESIGN DEVELOPMENT Page ii INTRODUCTION Section 1

Introduction

Harris County Hospital District selected Babendure Wheat Creative to develop a comprehensive directional and informational interior sign system to support the continuing revitalization of the Harris County Hospital District campus, and help to connect and strengthen all that gives the campus a unique sense of place .

BWC engaged the hospital community in the design of the Wayfinding & Signage Master Plan through a Signage Workgroup . From this, we built a mutual understanding of how people find their way around campus, design of the signs, and actual development of the finished products .

This Master Plan is designed to serve as a guide to the development and implementation of an interior signage and wayfinding system for Harris County Hospital District . It is a planning tool to be used over time as funding becomes available, as campus-wide improvements take place and for future district facilities . It is designed to grow with the facility, and possibly to expand to include additional sign types as needed . This manual documents each sign’s design and usage .

Design Responsibility The graphic design requirements shown on the sign type drawings in this manual are for design intent only and intended to establish basic dimensions and appearance . Within these limitations, the awarded Signage Contractor/Fabricators are responsible for fabrication of the entire system, and to make whatever modifications and additions may be required while maintaining the design concept as shown .

The Signage Contractor shall supplement the design shown with detailed shop drawings for the Graphic Designer’s approval . The shop drawings shall include major aspects of the system proposed, such as sections, shapes and connections of components, joints, how temperature movement is handled, venting, and anchorage .

Wayfinding System 1 . We held a kick-off meeting, the first in a series of analysis, evaluation, and work sessions with Harris County Hospital District . We reviewed the overall schedule and continued information-gathering with the Workgroup . 2 . During the information-gathering phase, we reviewed available information and conducted multiple surveys of all existing facilities to gain a full understanding of the primary facilities and its planned development . This information included the primary and secondary campus entrances, destinations and patterns of use . 3 . We analyzed pertinent functional relationships, including traffic circulation within the campus, in relation to surrounding public thoroughfares, and any future thoroughfares . 4 . We conducted a series of on-site meetings/presentations with the Workgroup to build consensus concerning needs, priorities, types of information to be communicated, and design directions . 5 . We assessed the major issues associated with the campuses and existing facilities (i e. . district identification, entries, phased implementation priorities, budget, etc .) We then coordinated with the Workgroup and appropriate decision makers in order to prioritize these issues .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 1.1 INTRODUCTION Section 1

Graphics Master Plan 1 . We prepared three preliminary concepts which were narrowed down to two to present to the committee . From these two concepts the family of graphics elements evolved, and we made recommendations to the committee for comment . 2 . We developed typographic and various color standards, which incorporate identity standards created in the wayfinding phase, for application to signage . 3 . We recommended sign and message types appropriate to each typical sign location, along with typical sign installation methods . Whenever possible, we used existing industry standard fixtures . 4 . We designed each of the sign types appropriate to the character of Harris County Hospital District, based on the construction, aesthetic, architectural and functional requirements identified during the information-gathering activities . 5 . We prepared typical design standards, materials, type faces, color families, appropriate graphic elements, message layout and the general overall appearance of each sign type .

QUALIFIERS The graphic design requirements shown by the details on these sign type drawing documents are for design intent only and intended to establish basic dimensions of units or modules, profiles and sight lines of members, and appearance . Within these limitations, the Signage Contractor is responsible for fabrication of the entire system, and to make whatever modifications of, and additions to the details as may be required . Maintain the visual design concept as shown, including members sizes, profiles and alignment of components as accurately as possible .

The Signage Contractor shall supplement the general design shown with detailed shop drawings for the Graphic Designer’s approval . The shop drawings shall include major aspects of the system proposed, such as sections, shapes and connections of components and joints, how temperature movement is handled, venting, and anchorage to structure . All ideas, design arrangements, or plans indicated or represented by these drawings are owned by, and remain the sole property of the Graphic Designer . No ideas, designs, arrangements, or plans shall be disclosed to any other person, firm, or corporation for any purpose whatsoever without the express written consent of the Graphic Designer .

All Artwork and Drawings required under the scope of these documents are to become the sole property of the Owner at the completion of the contract, with all original, or created artwork or drawings to be surrendered to the Owner at the end of fulfillment of the contract or sooner if requested in writing from the Owner .

All Artwork and Drawings are not to be reproduced or circulated for use outside the scope of this contract without written consent of the Owner . Failure to do so will result in legal action to the fullest extent of the law

NOTE: The term Signage Contractor applies to any entity who performs or is awarded all or part of the fabrication or installation to conform to the design documents, for this project . In some instances the term may apply to the same entity .

©Babendure Wheat CREATIVE . All rights RESERVED . No part of this document may be copied, reproduced or utilized in any form without prior and written authorization from Babendure Wheat Creative . This document serves as a device to communicate design intent only . Fabrication and installation of all products represented herein will be derived from the shop drawings produced by the project’s contracted fabricator .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 1.2 INTRODUCTION Section 1

Design Criteria

The following design characteristics and general guidelines are important to the success of a signage system:

User Friendly • Text is legible • Uncomplicated messages • Enhances perception of safety • Icons/Universal Symbols used where possible

Minimalism • Limited number of sign types • Provides only essential information • Limited quantity of signs in the environment

Aesthetically Pleasing • Harmonious to the architectural environment • Enduring design and typography • Appropriately scaled to the location

Maintainable • Easy to install/remove • Cleanable and reparable surfaces • Information can be easily changed or added • Low maintenance materials • Establish annual maintenance budget to repair or replace changing messages or damaged signs • Use of existing in-house machinery and staff

Vandal Resistant • No exposed access points • Tamper-proof screws and bolts • Strong structure securely installed • No costly materials

Orientation • Orient sign for greatest visibility from approaching traffic • Architectural elements, equipment, other signs, structures and decorations should not interfere with the visibility of the sign face .

Lighting • Reflective text should be used for vehicular directional and for exterior pedestrian directionals for greater legibility at night . • Parking identities and interpretive panels should be located so as to pick up ambient light wherever possible

Consistency • Maintain design constraints throughout the sign system. • Be sure that messages are consistent with each other and reinforce each other from vehicular to pedestrian systems . • Coordinate signage information with information distributed in patient information, brochures and maps .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 1.3 INTRODUCTION Section 1

How To Use This Manual

The Wayfinding & Signage Master Plan provides the design intent from which a signage component can be ordered . Each sign type contains multiple pages and all of these pages must be included as part of the bid, along with Section 3: Construction Standards, and Message Schedules and Project Schedule (not included in this Manual.) For a Bid Assembly checklist, refer to Section 8: Assemble A Package for Bid . If all information is not included in the Bid Package, the design intent may not be carried through to a successful completion . Knowing where to find the following information will be helpful:

1 . Usage On the first page of each sign type is a color illustration and a usage at the bottom . This tells the Sign Type Name and then gives a description . This will help you choose what Sign Types you need when putting together a Bid Package .

2 . Page Title At the top of every drawing page is a page title with Sign Type Number and Name . Remember to include EVERY drawing from a Sign Type in your Bid Package .

3 . Drawing Label Under each drawing is a Drawing Label which tells it’s order in the Sign Type, the viewpoint (front, top, side, etc), and the scale .

4 . Drawing Note & Note Bubble This Manual breaks down each drawing to explain the construction . Each detail is noted by a Note Bubble, which corresponds to a Note on the right .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 1.4 WAYFINDING STANDARDS Section 2

System Concept

At the core of the Harris County Hospital District Master Plan is the desire to create and reinforce a sense of place: to make the campuses, public areas or more memorable to inhabitants and visitors. To identify, as well as inform, within the context of a flexible and expansive graphics system, is only part of the intent . The other part is to celebrate those characteristics which make the campus unique—history, architecture, natural resources, events, community relationship and curriculum .

Following are objectives of the Harris County Hospital District Master Plan: • Reinforce campus boundaries and identity • Identify key entry points into the campus • Define pathways for vehicular traffic • Define pathways for vehicular traffic to parking areas • Define pathways for pedestrians from parking areas to the individual buildings • Create an awareness of destinations and promote those destinations • Emphasize special aspects of the campus which make it unique and interesting • Reduce the visual clutter or overuse of signs to reduce confusion • Enhance the perception of the campus as a safe, clean, and welcoming environment • Create a system consisting of simple components that are easily fabricated and easily maintained

The installation of environmental graphics alone will not accomplish all of these objectives . Because they are environmental, these signs will be affected by what is happening around them . For example, a vehicular directional sign may be totally lost if located among a lot of other signs or concealed by trees . A pedestrian directional would not be functional if located where there are no pedestrians .

Programming for the campus signage system is critical to its success . This is the process of determining what sign type is needed to help implement the wayfinding system, would be most appropriate at a particular location, what it should say, and how it should relate to all other signs within the system .

Sidewalks, landscaping, parks and public amenities such as street lamps, public phones, benches and trash receptacles all contribute to the perception of a welcoming environment .

Similarly, the development and enforcement of strict private signage codes improves the general appearance of the facilities and could help distinguish Harris County Hospital District from its competitors .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 2.1 WAYFINDING STANDARDS Section 2

Definition of Terms

Environmental Graphics. This form of visual communication is integrated into the environment to direct, inform, identify, and interpret . The term “environmental graphics” covers everything from wayfinding systems to interpretive graphics, to decorative embellishments for buildings and public spaces .

Wayfinding. This is a discipline that evaluates a geographic area or building from the perspective of a first-time user and facilitates access to and usage of the area . Wayfinding elements might include vehicular and pedestrian directional signage to lead visitors from roadways to parking and then to specific destinations .

Exterior Wayfinding System. Designed for the motorist, this directional system identifies a limited number of destinations and directs traffic to those areas . The system must begin at major decision points where traffic can be split and routed to general destinations along preferred routes .

Interior Wayfinding System. At the pedestrian scale, the level of information provided reinforces direction and helps orient the visitor . Included in this would be site identity signs, freestanding directionals, map graphics, interpretive units, and information kiosks designed to accommodate a changing menu of events . The pedestrian wayfinding system not only directs, it also implies graphically the layout of the “destinations” and begins to form a “network” which contributes to cohesiveness .

Pictograms/Icons. Elements of a visual language which graphically represent a place, object, theme or concept . Icons can cross language and literacy barriers, so are helpful devices when incorporated into a wayfinding or interpretive system . For example, the “P” used to indicate “Parking” or the “I” used to designate “Information” are commonly used icons/symbols .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 2.2 WAYFINDING STANDARDS Section 2

Wayfinding Analysis

The Wayfinding Process Wayfinding refers to the process by which one navigates, literally, finding one’s way around a place .

The wayfinding process occurs at the regional level, at a community level, on a campus, and inside a building . People obtain wayfinding cues from a variety of sources such as interior design, architectural styles, or decorative artwork, but the process is greatly aided by a coordinated system of signage . At both a vehicular and pedestrian level, wayfinding systems should mark routes to major roadways, districts, destinations, and specific locations such as landmarks and visitor parking areas . Effective signage should increase the legibility of a place by guiding visitors into and out of places they want to go .

Regional Wayfinding Concept A key to getting visitors to Harris County Hospital District facilities is to guide them onto the campus from key decision-making points in outlying areas . Motorists must first understand that there are things to see on the campus and then they must understand how to get there to see them . This is referred to as regional wayfinding .

Campus Wayfinding Once visitors reach Harris County Hospital District facilities from major routes, they must be able to discern a clear point of entry, or a gateway . Once inside the campus, Harris County Hospital District should be legible as a unified entity with a recognizable image . Signage at both a vehicular and pedestrian level should guide visitors to specific destinations such as building entrances, assigned building parking and community resources .

Building Wayfinding Once inside a building, visitors must be able to find clear pathways to the various public destinations and basic services such as restrooms or cafeterias . Facility-wide information should be made available at every major entrance . Signage should guide visitors along the pathways, presenting consistent information and distinguishing between public and staff destinations . At destinations, signage should help create a sense of arrival .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 2.3 WAYFINDING STANDARDS Section 2

Wayfinding Concept

A wayfinding system begins with support or creation of an area identity, definition of the boundaries for the area, then directing vehicles and pedestrians to specific visitor destinations within that area . The purpose of the system is to promote the use of public facilities, building uses, campus amenities and parking for Harris County Hospital District . Motorists entering the campus are greeted at those gateways that are not otherwise obvious, then organized and distributed to key destinations and parking via vehicular directional signs .

Identification System. Gateway signage is placed at the most important and least legible edges of the campus to welcome the visitor and to set the tone for the rest of the sign standards . Consistent use of graphic elements, logos, colors and structural components is key to reinforcing Harris County Hospital District’s identity . Color and design of the signage system will help to reinforce the identity even as it reinforces the image of the area .

Vehicular Directional System. This system helps lead vehicles from major traffic spines leading into the campus to major destinations or destination zones, and to parking areas along preferred routings . The vehicular directional system focuses on first-time or occasional users and visitors . This part of the signage system contains limited amounts of information so as not to confuse drivers . The vehicular directionals are located at key decision-making intersections, and appear frequently enough so as not to “lose” the driver . They may be augmented by identity signs for public, handicapped or visitor parking opportunities . Once the driver has reached a parking area, the pedestrian system takes over .

Pedestrian Directional System. For the pedestrian leaving the vehicle at a parking destination, the pedestrian directional system reinforces direction and orientation . This level of signing includes specific destinations that are within walking distance, as well as map elements to help orient the user . These signs should be located to reinforce predetermined routings so that the visitor never feels lost or unsafe . The pedestrian system includes directional signs, information kiosks or directories with orientation maps, and identity signs for the buildings and entrances . In a phased installation program, the pedestrian directional system should initially concentrate on those streets that provide the type of activities that most attract visitors . Other amenities besides signage that contribute to the success of the pedestrian directional system include clean sidewalks, pedestrian-scale lighting, benches, trash receptacles, bike racks, public phones, and greenscaping . As such improvements are made, the pedestrian directional system may be expanded .

Decorative/Seasonal Graphics. As a supplement to the other elements, these can take any number of forms and help to create a visually exciting environment . Banners are currently used to promote special events, or to simply reinforce the boundaries of Harris County Hospital District and its various areas . These may be changed frequently to continually refresh the image of the college for faculty, students and visitors alike . Other temporary enhancements, such as construction barricade fences, provide an excellent backdrop for graphics and a palette for community involvement . Other decorative elements may include flags, seasonal or specialty lighting, special events posters in directory kiosks, parking lots or garages—anything that helps visually celebrate and reinforce Harris County Hospital District’s changing menu of events and seasons .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 2.4 WAYFINDING STANDARDS Section 2

A Multi-Cultural Solution. The issue of accommodating Harris County’s diverse multi-cultural population was a primary design concern . Presently some of the wayfinding and signage is presented in three different languages . As we surveyed each existing clinic and hospital it became evident that the primary three languages vary by location . Multiple dialect variations of some languages increase the error in translations and multilingual messages create wall and ceiling space problems due the increased size of the signs . It is the goal of this design to reduce and eliminate multiple language signs where possible .

The wayfinding premise is based on the Houston METRO Transit System . All primary destinations (where is the Patient or Visitor must find their way) are given an alphanumeric address, like METRO . (See Figure 1 below and Figure 2 on Page 2.6) Each Patient or Visitor will be given the address at the Primary Facility Directory, at the Information Desk or through the printed Admitting form provided by the Facility . Assistance instructions in each primary languages will appear on all wayfinding signs . The Information Desk will have printed maps and information in the primary languages of the facility . This approach allows flexibility and eases the maintenance headache when destinations move or names change .

FIGURE 1 Below is an example of a Destination Sign, which displays the architectural facility room number, department or service area name and the Destination Address .

Architectural Facility Room Number

1.EC.45.1

Emergency Center Department or Service Area Name Patient Check-In

Destination Number: Main Entrance to 1D Department or 13 Service Area

Route (Hall) Floor

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 2.5 WAYFINDING STANDARDS Section 2

FIGURE 2 Below is an example of the route system used to identify and number primary destinations . Here, the pharmacy is located on the first floor at the beginning of the “A” route, so it’s full Destination Address is “1A 01 ”.

The numbering scheme leaves unused numbers to allow for possible expansion or renovation .

Clinic Pharmacy Clinic 1A 12 1A 01 1A A15 04

A10 A05 A00 Information 1A 09 1A 1A Cinic 05 02 Clinic Vending 1B 01 B00 B05

Clinic 1B 09

B10

Clinic 1B 15 B15

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 2.6 CONSTRUCTION STANDARDS Section 3

Sign Placement

Following are general guidelines for placement of vehicular, pedestrian and interior signs as viewed when approaching the sign .

Vehicular Directionals • Signs must be placed within the driver’s immediate cone-of-vision so that they do not have to turn their heads to see the sign . • The sign face should be perpendicular to the approaching driver. It will be overlooked if it is parallel to the road . • Signs should be placed on the right side of the road whenever possible. Drivers are conditioned to look to the right side of the road for signs with information .

An exception to this is when a sign is to be read from both directions of approaching traffic, as in the case of double-faced signs . If a double-faced sign is used instead of two single-faced signs on both sides of the road, the double-faced sign should be located for clear readability from both directions of approaching traffic . Also, if the messages require queuing to the left, the sign may be located to the left to provide advance warning . • Signs which require drivers to turn must be placed well enough in advance of the intersection in order to allow for reaction time to slow down and turn . •  Signs should not overhang into the roadway if located on a sidewalk or street post.

Pedestrian Directionals • Signs should be placed within a visible area along the path of . Signs should be located so as not to interfere with pedestrian traffic, nor should they block important roadway signage or obstruct views of roadway traffic . • Pedestrian signs have been designed to mount to existing structures, or to custom posts. Specific mounting heights are shown in the drawings for the individual sign types . • Wall or fence-mounted signs should be placed high enough so as not to be blocked by cars and plants or other obstructions . This will generally range between 6’ to 7’ above the ground . Mounting height is measured from the ground level to the bottom of the sign panel . • Consideration should be given to locating pedestrian signs in areas which receive ambient light from other light sources to create better visibility at night .

For all signs, mounting locations should be carefully considered so that viewing is not obstructed by other signs, trees or structures . In some cases, it may be necessary to remove and/or consolidate information presented by other signs, and will be subject to the approval of the Traffic Engineering Director . Where a new sign is replacing an older sign which does not comply with the standards in this manual, the entire sign assembly should be replaced . Old sign posts should be removed and replaced with the new custom posts, again, subject to the approval by the Traffic Engineer .

Interior Signs • To comply with ADA requirements, door signs must be mounted at a height of 5’-0” to the center of the sign . This is also true for directional and directory signs . • Door signs must be mounted 3” away from the door jamb on the side of the door pull. • Overhead signs must be mounted to maintain a minimum of 7’-0” clearance. • Overhead signs should be perpendicular to the pedestrian flow of traffic. It will be overlooked if it is parallel . • In long hallways or traffic routes, “reminder” signs should be placed along the length, even if there are no other choices for turning . This will reassure the pedestrian that he or she is still on the correct path .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.1 CONSTRUCTION STANDARDS Section 3

STANDARD MOUNTING LOCATIONS

Unless otherwise noted in drawings, use the guidelines below when locating a sign.

OVERHEAD SIGNS DOOR SIGNS WALL SIGNS

3" . . F 7'-0" A. F 5'-0" 5'-0"

ELEVATOR SIGNS

center over call button 2"

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.2 CONSTRUCTION STANDARDS Section 3

Construction Standards

(Sections 1.0-3.8 may be deleted in lieu of HCHD General Conditions to Contract)

1.0 INTRODUCTION The purpose of this document is to serve as a reference which identifies materials, construction specifications, and quality controls, as well as signage fabricator/contractor’s responsibilities and obligations . Signage Contractor(s) shall furnish and install signs and/or graphics as detailed on drawings and/or described in these specifications . Signs shall carry messages and images as specified in the attached Sign Message Schedule . Quantities shall be as called for in the attached Signage Bid Table . (Sample form provided in Section 8.)

2.0 DEFINITION OF TERMS

2 1. DOCUMENTS Refers to the drawings, specifications, sign message schedule, including all addendum and modifications incorporated therein before their execution . When applicable, additional appendages provided by Owner, Owner’s Representative or General Contractor shall also become part of the contract documents .

2 .2 OWNER Shall refer to: Harris County Hospital District 2525 Holly Hall Houston, Texas 77054

2 .3 OWNER’S REPRESENTATIVE OR GENERAL CONTRACTOR N/A

2 .4 Graphics Designer Shall refer to: BABENDURE WHEAT CREATIVE Contact: Heather Chandler 1004 Truxillo, Studio F Houston, Texas 77004 Tel > 713 533. 1960. Fax > 713 533. 1961.

2 .5 Signage Contractor / Fabricator Refers to the group(s), firm(s), or corporation(s) designated as such in an Agreement with the Owner or designated representative of the Owner (such as Owner’s Representative, General Contractor or others), and shall apply to any such group(s) under contractual obligation to perform any fabrication, installation, finishing, printing or other work related to the signs and graphics, as referenced within this document .

2 .6 Work As employed herein, includes any material, equipment, construction, labor, installation, service or maintenance, and warranties required to complete the fabrication prescribed in these specifications and contract documents . This shall include, but not limited to, all of the sign types listed in the sign message schedule and drawings .

2 7. Addenda Covering changes, corrections, and special interpretations of the drawings and specifications, shall become a part of the documents .

2 .8 Substitutions When one or more than one product is specified and the Signage Contractor wishes to offer a substitute product which will completely accomplish the purpose of the contract documents . See Section 6 0. for the conditions governing all substitutions .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.3 CONSTRUCTION STANDARDS Section 3

2 .9 Approved, Acceptable or Satisfactory Shall be understood as approved by, acceptable with, or satisfactory to the Owner/Designer . Equal or satisfactory approved equal items and substitutions thereof shall be considered only prior to time of bid and must be clearly identified to Owner/Designer as such .

Where observed discrepancies occur between documents (drawings, schedules, or specifications) or within a document section, submit notice of same and assumption concerning same with proposal, and attached letter with proposal setting forth discrepancy and basis used in proposal . Thereafter, the item or arrangement of better quality, greater quantity, or higher cost shall be deemed included in the bid .

2 10. Not In Contract (N I. C. .) Refers to work not included in this contract .

2 11. Final Completion The date when the Graphic Designer finds the entire work as described in the contract documents, acceptable and fully performed, as written in the final certificate of payment .

3.0 GENERAL CONDITIONS

3 1. Quality Assurance The Signage Contractor shall be responsible for the quality of materials and workmanship required for the execution of this contract including the materials and workmanship of any firms or individuals who act as his sub-contractors .

It is intended that the work described in these documents be of sound, quality construction . The Signage Contractor shall be solely responsible for the inclusion of adequate amounts to cover installation of all items indicated, described and/or implied .

3 .2 Commencement The work described in these documents shall only begin when an Owner-authorized, written subcontract has been issued to the Signage Contractor with instructions to proceed, provided other requirements have been met .

3 .3 Contract Administration Reviewing the quality and progress of the work and submittals received from the Signage Contractor, the Graphic Designer is acting solely for the convenience of the Owner in following the work . The Graphic Designer has no responsibility to assist the Signage Contractor in the supervision or performance of the work . No action by the Graphic Designer shall in any way relieve the Signage Contractor from his responsibility for the performance of the work in accordance with the contract documents, or give rise to any negligence or other action against the Owner or the Graphic Designer or anyone acting for or on behalf of either of them .

Signage Contractor shall allow Owner’s Representative or an authorized representative complete access to his plant, excluding such areas or processes judged by the Signage Contractor to be of a highly secretive or proprietary nature, for the purpose of inspecting production techniques, materials, or other items related to the manufacturing of which the Owner is committed, or which may be contemplated .

Upon notification from the Signage Contractor that all work is complete, the Graphic Designer will inspect the final installation for compliance with all approved documents . Additional hours spent by Graphic Designer’s personnel on documentation, coordination, and additional site visits required by incorrect, incomplete, or faulty workmanship on the part of the fabricator, will result in a deduction from the Signage Contractor’s contract amount for the fees and expenses accumulated by the additional hours expended .

3 .4 Retainage Refer to the provisions and conditions governing retainers as provided in the contract documents of the Owner . All payments and invoices shall be submitted to the Graphic Designer for initial approval . The Graphic Designer will review all invoices for accuracy and completion of work, and forward to the Owner with any recommendations or comments .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.4 CONSTRUCTION STANDARDS Section 3

3 .5 Extensions The conditions of such extensions will be regulated by the provisions in the contract documents of the Owner . A . The following represents the Graphic Designer’s standard extension policy, which may or may not be in accordance with the Owner’s requirements: 1 . In consideration for an extension in the time required to perform the work as specifically outlined in the contract, the Signage Contractor must furnish such justification and supporting evidence as the Owner and/or Graphic Designer may deem necessary . 2 . All claims for extensions of time shall be made in writing and submitted to the Graphic Designer within three (3) days of the first instance of the delay . The Signage Contractor shall provide a written estimate of the probable effect of such delay on the progress of work . 3 . A careful review of supporting evidence will be made by the Graphic Designer . Should the Graphic Designer find that the Signage Contractor is entitled to any extension in the time allowed for completion of work, the Graphic Designer’s determination upon the total number of days to be extended shall be based upon the currently approved schedule and all data relevant to the extension . Such data will be incorporated into the schedule as a revision thereto . B . Subject to other provisions of the contract, the Signage Contractor may be entitled to an extension (but no increase in the con tract sum) for delays arising from unforeseeable causes beyond the control and without the fault or negligence of the Signage Contractor or his subcontractors as follows: 1 . Labor disputes and strikes (including strikes affecting transportation) that do, in fact, directly and critically affect the progress of the work . However, an extension on account of an individual labor strike shall not exceed the number of calendar days of said strike . 2. Acts of God, tornado, fire, hurricane, blizzard, earthquake, typhoon or flood that damage completed work or stored materials . 3 . Abnormal inclement weather . However, an extension will not be considered as a result of adverse weather conditions reasonably anticipated .

3 .6 Penalties The Owner’s contract and conditions of the project shall regulate the penalty clauses .

3 7. Artwork Provided for spacing only . The Signage Contractor will produce artwork for all symbols and lettering, and will submit to the Graphic Designer for review and approval prior to fabrication . Artwork for specific items and logos, as noted in the drawing document, shall be provided by the Owner . All other artwork, as well as final artwork for fabrication (including reproducible film positives) is to be provided by the Signage Contractor .

The Signage Contractor may be required to refine said artwork for sake of reproduction . All special dyes prepared for graphic items shall become the property of the Owner and are not to be used further without written permission .

3 .8 Other Field dimensions shall be taken by the Signage Contractor prior to preparation of shop drawings and fabrication where possible . Allow time for trimming and fitting wherever the taking of field measurements before fabrication might delay work .

All supplementary parts necessary to complete each item shall be furnished by the Signage Contractor, even though such parts are not definitely shown or specified . All anchors and other fasteners for securing work to the construction shall be included .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.5 CONSTRUCTION STANDARDS Section 3

4.0 SIGNAGE CONTRACTOR RESPONSIBILITIES

4 1. Design Responsibility The graphic design requirements shown by the details on the sign type drawing documents are for design intent only and intended to establish basic dimensions of units or modules, profiles and sight lines of members, and appearance . Within these limitations, the Signage Contractor is responsible for fabrication of the entire system, and to make whatever modifications of, and additions to the details as may be required . Maintain the visual design concept as shown, including members sizes, profiles and alignment of components as accurately as possible .

The Signage Contractor shall supplement the general design shown with detailed shop drawings for the Graphic Designer’s approval . The shop drawings shall include major aspects of the system proposed, such as sections, shapes and connections of components and joints, how temperature movement is handled, venting, and anchorage to structure .

4 .2 Statement of Application The Signage Contractor, by commencing the work of the project, assumes overall responsibility, as a part of his warranty of the work, to assure that all assembled components and parts shown or required within the work of this project comply with the contract documents . The Signage Contractor shall further warrant: A . That all components specified, or required, to satisfactorily complete the installation, are compatible with each other and with the conditions of installation and expected use; B . The overall effective integration and correctness of individual parts and the whole of the system; C . Compatibility with adjoining substrate, materials and work by other trades; D . There shall be no premature material failure due to improper design or fabrication of the system . All materials are to fully perform to their normal life expectancy .

4 .3 Execution The Signage Contractor shall be responsible for all work done under his contract, including: A . Faulty or improper work of subcontractor(s) and others under him by contract or otherwise; B . Diligent execution of work and giving his personal attention and supervision to same until completed; C . All delays caused by neglect on his part or of those under him by contract or otherwise; D . Compliance with all laws, ordinances and regulations bearing on the conduct of the work as drawn and specified . E . Obtaining, at his own cost, inspection certificates which may be required of the project by local authorities, or any other governing body . The Signage Contractor shall procure and pay for all permits, licenses and approvals necessary for the execution of the work .

4 .4 Submittals By the approval and submission of shop drawings and samples, the Signage Contractor thereby represents that he has determined and verified all field measurements, field construction criteria, materials, catalogue numbers and similar data or will do so, and that he has checked and coordinated each shop drawing and sample with the requirements of the work and the contract documents . Refer to Section 5 0. for a list of required submittals .

4 .5 Special Instructions Halt the graphics work when notified of a proposed change, or if unsatisfactory results are anticipated . Notify the Graphic Designer immediately and proceed only after receiving additional instructions from the Graphic Designer and/or Owner .

4 .6 Acts and Omissions The Signage Contractor is responsible for having free access to the premises for the purpose of acquainting himself with the conditions, delivering furnishings and equipment and performing the work under this contract . He should cooperate with the separate contractors who may currently be working on the premises, integrating the work with that of others, all to the best interest of the project and its orderly completion . Damages to the building contents, when such damages result from the use of faulty materials or negligent workmanship, shall be the responsibility of the Signage Contractor .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.6 CONSTRUCTION STANDARDS Section 3

4 7. Protection and Handling of Products Store all graphic items under cover and off the ground . Handle in such a manner so as to protect surfaces and to prevent damage during storage, installation, and throughout remaining construction . Protect exposed finishes by covering with adhesive paper or other suitable covering where adhesive is not appropriate for finish material . Apply covering prior to shipment from the fabricating or finishing shop . Covering shall not adversely affect finish . Remove protective coverings when there is no longer any danger of damage to the graphics work from other work yet to be performed .

4 .8 Shipping and Transportation Signage Contractor will be responsible for proper shipping and transportation of all signage to the job site and will specify whether it will be common carrier or on his own trucks . Fabricator will be liable for all damage incurred during shipping and loss of time in the installation schedule .

4 .9 Storage of Equipment Space for storage of material prior to installation will be designated by the Owner . The Signage Contractor must give advance notice of deliveries and space requirement so that proper provision may be made . If deliveries are to be made to the premise at times other than normal working hours, the Signage Contractor will be required to reimburse Owner for any overtime costs incurred by the Owner .

4 10. Warranty Upon final completion, the Signage Contractor will warrant all work and materials to be in full and complete accordance with the contract documents and agreement between Owner and Signage Contractor, and requirements appertaining thereto; that all work and materials are free from any and all defects and imperfections, and fully meet the manufacturer’s published performance criteria for the use and purposes for which each and every part is specified .

The Signage Contractor also agrees that, should any defect develop or appear, which the Graphic Designer and/or Owner finds was not caused by improper use, the Signage Contractor shall promptly, upon demand, fully correct, substitute and make good any such defective material without any cost to the Owner and will save the Owner harmless against any claim, demand, loss or damage by reason of any breach of this warranty .

The period of this warranty shall commence on the date on which the Graphic Designer determines the Signage Contractor has met all Final Completion requirements . The period of said warranty shall last twelve (12) months unless otherwise specified .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.7 CONSTRUCTION STANDARDS Section 3

5.0 SUBMITTALS All submittals and shop drawings are to be delivered to the Graphic Designer for distribution .

5 1. Schedule A detailed graphic schedule by phases of production and installation is to be submitted by the successful bidder no later than five (5) days upon signing of the contract .

5 .2 Samples Submit 3 3” x 3” samples of each color and finish of exposed materials and accessories, or final material substrate to be use in the project . They are as follows:

PAINT P-1 Black Matthews Paint MP30132 Satin Finish P-2 White Matthews Paint MP11477 Satin Finish P-3 Red Matthews Paint MP15351 Satin Finish P-4 yellow Matthews Paint MP00053 Satin Finish P-5 Orange Matthews Paint MP00176 Satin Finish P-6 Purple Matthews Paint MP00878 Satin Finish P-7 Blue Matthews Paint MP02110 Satin Finish P-8 Green Matthews Paint MP14334 Satin Finish P-9 Pink Matthews Paint MP08744 Satin Finish P-10 Brown Matthews Paint MP00158 Satin Finish P-11 Silver Matthews Paint 41342SP Satin Finish P-12 Exterior Blue Matthews Paint MP02306 Semi-Gloss Finish P-13 Exterior White Matthews Paint MP11477 Semi-Gloss Finish P-14 Exterior Gray Matthews Paint MP15661 Semi-Gloss Finish P-15 Exterior Met . Silver-Gry Matthews MP18205 Semi-Gloss Finish P-16 HCHD Blue Matthews Paint Match PMS 289 Satin Finish P-17 HCHD Tan Matthews Paint Match PMS 465 Satin Finish P-18 Duranotic Bronze Matthews Paint MP20356 Semi-Gloss Finish

VINYL V-1 Black 3M Scotchcal 7725-22 Matte Black Opaque V-2 White 3M Scotchcal 7725-20 Matte White Opaque V-3 Red 3M Scotchcal 7725-63 Geranium Opaque V-4 Silver 3M Scotchcal 7725-12 Satin Aluminum Opaque V-5 Blue 3M Scotchcal 7725-37 Sapphire Blue Opaque V-6 Green 3M Scotchcal 7725-186 Bright Green Opaque V-7 Tan 3M Scotchcal 7725-39 Tan Opaque V-8 Translucent Blue 3M Scotchcal 3630-157 Sultan Blue Translucent V-9 Translucent Tan Oracal 8500 series 081 Light Brown Translucent

Submit one (1) control sample of the following for the Graphic Designer’s approval before beginning final production: INT 05. Department ID with Sub-departments

These samples shall become the property of the Graphic Designer .

5 .3 Shop Drawings Submit one (1) reproducible copy of shop drawings in ledger format (11” x 17”), for the manufacturing, fabrication and erection of signs and graphic work at large scale . Show jointage, anchorage, accessory items, and finishes . A . Acceptance of shop drawings does not in any way change the documents . Documents may only be changed in writing . B . The Signage Contractor is responsible for reviewing shop drawings for conformance with the documents and notifying, in writing, the Graphic Designer of any variation from the documents . C . Changes to the shop drawings are to be made by the Signage Contractor as directed by the Graphic Designer .

5 .4 Copy Layouts Copy layouts are to be provided for each sign type . Submit full-scale drawings of typical sign faces showing copy layout . Half-scale drawings will be sufficient for sign faces 40” x 40” and larger . For multiple-message sign types, a typical of each variation to the original layout should be provided .

5 .5 Manufacturer’s Data Submit one (1) copy of the manufacturer’s printed specifications, anchorage details and installation, and maintenance instructions for products to be used in the fabrication of signs and graphics work .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.8 CONSTRUCTION STANDARDS Section 3

6.0 SUBSTITUTIONS

6 1. Any substitutions requested after the award of the contract will be considered only under these cases: A . When the specified product is not available; B . When a certain product or process is specified, a warranty of performance is required, and, in the judgement of the Signage Contractor, the specified product or process will not produce the desired results . C . When such substitution, in the opinion of the Graphic Designer, is in the best interest of the Owner .

6 .2 Request for substitutions of products, materials or processes other than those specified will be accompanied by the evidence that the proposed substitution, A . Is equal in quality and serviceability to the specified item; B . Will not entail changes in details and construction of related work; C . Will be acceptable in consideration of the required design and artistic effect; D . Will provide a cost advantage to the Owner .

The Signage Contractor shall furnish with his request such drawings, specification samples, performance data and other information as may be required of him to assist the Graphic Designer in determining whether the proposed substitution is acceptable . The burden of proof shall be upon the Signage Contractor .

6 .3 Regardless of the evidence submitted or any review or independent investigation by the Owner or the Graphic Designer, a request for a substitution of products, materials, or processes is a warranty by the Signage Contractor to the Owner and Graphic Designer that the requested substitution, A . Is equal in quality and serviceability to the specified item; B . Will not entail changes in details and construction of related work; C . Will be acceptable in consideration of the required design and artistic effect; D . Will not involve any change in cost to the Owner other than that specified in an accompanying request for a change order .

6 .4 Proposed substitutions will be made within five (5) days after the award of the contract, except when circumstances are beyond the Signage Contractor’s control . Submit requests for substitutions to the Graphic Designer in writing, giving sufficient information and samples for evaluation with the difference in costs, if any . Substitution must be approved in writing by the Graphic Designer and the Owner before they may be used .

7.0 FABRICATION Shop fabrication and tolerances shall conform to the standards of the industry . All items shall be shop fabricated so far as practicable . Perform high-quality, professional workmanship . Attach materials with sufficient strength, number and spacing not to fail until materials joined are broken or permanently deformed . Fabricate all work to be truly straight, plumb, level and square and to sizes, shapes and profiles indicated on the approved shop drawings .

7 1. Shop Assembly Preassemble items in shop to greatest extent possible to minimize field splicing and assembly . Disassemble units only as necessary for shipping and handling limitations . Clearly mark units for reassembly and coordinated installation .

7 .2 Welding All welding procedures shall conform to applicable AWS specifications . All welds shall develop capacity of members being joined unless specific length or extent is noted on the drawings . Type of alloy filler metal and electrodes to be that which is recommended by producer of the metal to be welded, and as required for color match, strength and compatibility in the fabricated items .

7 .3 Flatness of Panels Panels shall show no visual distortion when viewed in installed position . All panel faces shall be of such flatness that when measured, the maximum slope of the surface at point, measured from the nominal plane of the surface, shall not exceed 1 0%. . Any panel not meeting these requirements is subject to rejection by the Graphic Designer .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.9 CONSTRUCTION STANDARDS Section 3

7 .4 Wind Loading Exterior signs shall be designed to withstand wind pressure loadings of 30 psf (146 .5 kg/sq m). on the gross area of the exposed units, acting in all directions or to meet and/or exceed all applicable codes, whichever is greater . The Signage Contractor will not be required to have structural elements of exterior signs stamped by an engineer . Standard and approved methods of fabrication will be required by the Graphic Designer .

7 .5 Thermal Movement Design, fabricate and install component parts to provide for expansion and contraction over a temperature range for the material of 150 degrees Fahrenheit (83 .3 degrees Celsius), without buckling, sealant joint failure, glass breakage, undue stress on members or anchors, and other detrimental effect .

7 .6 Wrought Work Wrought work shall be leveled and straightened . Members shall have sharp lines and angles and smooth surfaces . Extruded members shall be free from extrusion marks . Square turns and corners shall be sharp . Curves shall be true .

7 7. Castings Castings shall have fine, even texture and shall be un-warped and sound . Lines and meters shall be sharp, arises unbroken, profiles accurate and ornament true to pattern . Plane surfaces shall be smooth . Ornament shall not have excess material or imperfections that obscure design, undercut to restore detail . Filed or cut areas shall have texture restored .

7 .8 Corrosion Protection Coat concealed metal surfaces which will be in direct contact with concrete, masonry, wood or dissimilar metals, in exterior work, and work to be built into exterior and below grade walls and decks, with a heavy coat of bituminous paint . Do not extend coating onto exposed surfaces .

7 .9 Metric Conversion Stock or standardized materials sized in metric and not equivalent to U .S . standard may be provided if approved .

7 10. Other Holes for bolts and screws shall be drilled . Parts to receive hardware shall be countersunk . Fasteners shall be of basic metal and alloy, matching finished color and texture as the metal being fastened, unless otherwise indicated . There shall be no exposed fasteners; all fasteners shall be concealed . Exposed ends and edges shall be milled smooth, with corners slightly rounded . Joints exposed to weather shall be formed to exclude water .

Design components to allow for expansion and contraction for a minimum material temperature range of 150 degrees Fahrenheit, without causing buckling, excessive opening of joints or over- stressing of welds and fasteners. Joints shall be fastened flush to conceal reinforcement, or welded where thickness of section permits . Contact surfaces of connected members shall be ground true . Parts shall be so assembled that joints will be tight and practically unnoticeable, without use of filling compound .

Form work to the required shapes and sizes, with true curves, lines and angles . Provide necessary rebates lugs and brackets for assembly of units . Use concealed fasteners wherever possible . Plates for mounting hardware shall be welded in place .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.10 CONSTRUCTION STANDARDS Section 3

8.0 INSTALLATION The installation of fixed material shall be under the general direction of the Graphic Designer in accordance with applicable specifications and layout drawings .

8 1. Preparation Coordinate setting drawings, diagrams, templates, instructions and directions for the installation of items having integral anchors which are to be embedded in concrete or masonry construction . Coordinate delivery of such items to applicable trades for installation .

8 .2 Delivery to Premise Unless indicated to the contrary, items of loose material shall be delivered, uncrated, assembled, set in proper place and installed ready for use, free from breakage, blemishes or other defects .

8 .3 Inspection Examine the substrate and the conditions under which the materials are to be installed . Do not proceed with the work until unsatisfactory conditions detrimental to the timely and proper completion of the work have been corrected .

8 .4 Anchors and Inserts Furnish inserts and anchoring devices which must be set in concrete or built into masonry for installation of this work . Provide setting drawings, templates, instructions and directions for installation of anchorage devices . Provide toothed steel or lead shield expansion bolt devices for drilled-in-place anchors and inserts for exterior installation . Provide units with exposed surfaces matching the texture and finish of metal item anchored .

8 .5 Cutting, Fitting and Placement Perform all cutting, drilling and fitting required for installation . Set the work accurately in location, alignment and elevation, plumb, level and true, measured from established lines and levels . Provide temporary bracing or anchors as required .

Form tight joints with exposed connection accurately fitted with uniform reveals and spaces for sealants and joint fillers . Where cutting, welding and grinding are required for proper shop fitting and jointing of the work, restore finishes to eliminate any evidence of such corrective work .

Do not cut or abrade finishes which cannot be completely restored in the field . Return items with such finishes to the shop for required alterations, followed by complete refinishing or provide new units at Signage Contractor’s option .

8 .6 Erection All surfaces shall be covered with protective cover non-deleterious to finish for protection until final installation or erection . Complete all connections in proper alignment and tighten bolts securely . Leveling is to be done only by instruments; measuring equal distances from existing building surfaces will not be acceptable as a basis of level and/or plumb . After erection, all surfaces marred during erection and exposed bolts, bolt heads, etc ., shall be retouched with the same paint used previously .

8 7. Electrical All electrical lighting and power devices contained within or upon signage devices which are usually included as part of the illumination system of that device such as lamps, sockets, internal wiring, etc . Additionally, the Signage Contractor is responsible for electrical connection only of signage items . Power distribution to required locations shall be the responsibility of the Owner or his designated agent unless otherwise specifically noted on the drawings .

8 .8 Protective Coverings Restore protective coverings which have been damaged during shipment or installation of the work . Remove protection when requested for inspection of finishes and replace . Retain protective coverings intact and remove simultaneously from similar finished items to preclude non-uniform oxidation and discoloration . Remove protective coverings only when there is no possibility of damage from other work yet to be performed at the same location .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.11 CONSTRUCTION STANDARDS Section 3

8 .9 Cleaning of Premises The Signage Contractor shall use special care in the disposition of excess materials and rubbish . Rubbish shall not be allowed to accumulate but shall be consistently collected and removed at the completion of this work, on a daily basis .

Storage for paint materials, preparation and mixing, shall be in well lit and ventilated central location but shall not be allowed on finished or carpeted flooring. Ample protection by means of drop cloths or layers of paper must be provided for existing apparatus or parts of the building .

Adequate safeguards shall be provided against fire by placing oils, rags and waste in self-closing metal receptacles and shall be removed from the work and storage area at the end of each work shift . Under no circumstances will they be allowed to accumulate .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.12 CONSTRUCTION STANDARDS Section 3

Material Specifications

9.1 ALUMINUM Aluminum used for exposed structural elements shall be T-5 mill aluminum, thickness as shown on the drawings . Aluminum used for concealed framing of signage shall be 6063 T-5 alloy with mill finish .

9 1. 1. EXTRUSIONS Shapes and thicknesses as shown and as required to fulfill requirements, but not less than 1/8” (3 .2 mm) thick, unless otherwise shown . Suitable alloy and temper for extruding with adequate structural characteristics and suitable for finishing as specified .

9 1. .2 SHEETS AND PLATES Sizes and minimum gauges as shown and as required to fulfill performance requirements . Suitable alloy and temper for forming and fabrication requirements with adequate temper and structural characteristics and suitable for finishing as specified .

9 1. .3 CASTINGS ASTM-B-26 or B-108, alloy 214 for natural anodized finish, and alloy 43 for color anodized or baked enamel finish .

9 1. .4 FINISHING Aluminum finishes shall be acrylic polyurethane two-part catalyzed coating system . All coating applications shall be prepared and spray applied in the factory by skilled mechanics . All surfaces shall be mechanically sanded removing all grain lines, striations, and surface blemishes, cleaned with non-abrasive scouring pads, rinsed, and air-dried prior to receiving coatings . A . Coatings shall be prepared as designated by manufacturers latest literature for surface preparation and application but in no case less than one (1) applicable primer coat and two (2) final full coats . All finished surfaces shall be uniform . B . Colors shall match color designations as indicated on the drawings .

9 1. .5 ANODIZING Exterior Application: For a clear anodized (natural) finish use AA-M21C22A41 with a minimum 0 7. mil (0 02. mm) . For a color anodized finish use AA-M21C22A42 with a minimum 0 7. mil (0 02mm). to match samples provided by Graphic Designer .

Interior Application: For a clear anodized (natural) finish use AA-M21C22A31 with a minimum 0 .4 mil (0 01. mm) . For a color anodized finish use AA-M21C22A32 with a minimum 0 .4 mil (0 01. mm) to match samples provided by Graphic Designer .

9.2 BRASS / BRONZE

9 .2 1. ALLOYS Alloy numbers specified below refer to standards of the Copper Development Association (CDA) . A . Extrusions: Architectural bronze, alloy 385 B . Sheet and Plate: Muntz metal, alloy 280 C . Castings: Series 800 and 900 alloy best suited for color matching .

9 .2 .2 FINISHING Provide finishing complying with CDA designations, matching samples provided by Graphic Designer or Owner . A . Polished Finish: M21M34C12 with clear urethane coating for exterior applications, and two-coat application of carnauba wax, hand buffed, for interior applications . B . Satin Finish: M31C12 with clear urethane coating for exterior applications, and two-coat application of carnauba wax, hand buffed, for interior applications . C . Statuary Finish: M32C12C55 D . Chrome Plated Finish: ASTM-B-456, Type SC-2 over a coating of copper and nickel . Provide a bright polished finish unless otherwise shown .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.13 CONSTRUCTION STANDARDS Section 3

9 .3 CARVED SIGNS Carved signs shall be performed by a qualified sign carver of at least five years experience in the type of work required, shall have an artistic reputation and shall have recently successfully completed similar work of this magnitude . Colors shall match colors as designated on the drawings .

9 .3 1. MATERIALS Shall be select exterior grade carving woods of cedar or redwood or high-density urethane foam with a density of not less than 10-12 lbs .

9 .3 .2 COATINGS Carved signs shall receive finish coatings suitable for external exposure which will not chip, fade, crack, or craze . Coatings shall be spray applied where applicable with at least one (1) prime coat or other surface pre-treatments and no less than two (2) final coats .

9.4 CONCRETE

9 .4 1. REFERENCE STANDARDS Strictly comply with the following referenced standards: ACI 318, ACI 614, ACI 306, ACI 347, ACI 315, ACI 302 and CRSI Manual of Standard Practice .

9 .4 .2 PORTLAND CEMENT CONCRETE Comply with ASTM C94 . Proportion mixes in compliance with ACI 301 . Provide concrete having minimum 3000 psi compressive strength at 28 days, 3” to 4” slump, 4% to 6% entrained air for concrete exposed to freezing and 2% to 4% for all other concrete, and minimum 5 .5 sacks of cement per cubic yard of concrete .

9 .4 .3 REINFORCING Provide ASTM A615, Grade 60, new, deformed rebars . Provide ASTM A185, new, rectangular welded wire fabric .

9 .4 .4 FORMWORK Contractor’s option, but shall be suitable to provide straight, flat, accurately aligned surfaces within specified tolerances .

9 .4 .5 INSTALLATION Securely construct and brace formwork to provide concrete members and structures of sizes, shapes, elevations, profiles, alignments, and positions indicated within specified tolerances . Place and tie reinforcing in position and secure against displacement .

9 .4 .6 FINISHING Steel trowel slab surfaces to provide hard, slick, smooth, uniform planes within specified tolerances . Do not add cement, sand, water or mortar to slab surfaces .

9.5 COPPER Provide alloy 110 established by Copper Development Association (CDA) unless otherwise shown . In addition, comply with sheet, bar and strip of ASTM B-152 .

9.6 GATORBOARD FRP Flame retardant panel with the following minimum performance requirements .

9 .6 1. PHYSICAL PROPERTIES Standard Size: 48” x 96” Thickness: H” and I” Density: (H”) 23-24 PCF and (I”) 19-21 PCF

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.14 CONSTRUCTION STANDARDS Section 3

9 .6 .2 TYPICAL PHYSICAL PROPERTIES (Based on H” Thickness) • Internal Bond: 12-14 psi (typical value for the core) • Modulus or Elasticity: 280,000 psi approximately • Modulus of Rupture: 1,900 psi approximately • Compressive Strength: 60 psi at 10% deformation • Hardness Combustibility: Flamespread @ less than 25 (class A), Fuat Contributed @ 15, and Smoke Density @ less than 50 • Machinability: May be used with most types of woodworking equipment. However, special care must be taken when sawing as chip-out may occur . • Thickness: # 1/16” • Squareness: # 3/16” • Straightness: Within J” when comparing the two diagonal measurements between opposite corners or the panel . • Wrap: No manufacturing set. Wrap or curl greater than H”.

9 .6 .3 PAINTING Any water-based or solvent-based materials can be used on faces or edges . However, to maintain a Class ”A” flamespread, a coating classified as “Fire Retardant” by Underwriters Laboratories, Inc., is recommended .

9 .6 .4 MANUFACTURER(S) International Paper Uniwood Division Taylorsville Road Statesville, NC (704) 872-8974

9.7 GLASS

9 7. 1. PLATE OR FLOAT Clear: FS DD-G-451, Type I, Class 1, quality q3, 1/4” (6 .35 mm) thick, unless otherwise shown . Tinted (Heat Absorbing): FS DD-G-451, Type I, Class 2, Style B, quality q3 . Provide color as shown 1/4” (6 .35 mm) thick, unless otherwise shown .

9 7. .2 LAMINATED Provide laminated glass consisting of two sheets of plate or float glass of thickness required to achieve overall thickness shown, laminated at the factory using the manufacturer’s standard heat/ pressure process . Exclude dirt and other foreign materials from the lamination, and eliminate all voids and delaminated surfaces .

9 7. .3 TEMPERED Clear: FS DD-G-001403 kind FT, Condition A, Type I, Class 1, 1/4” (6 .35 mm) thick, unless otherwise shown . Tinted (Heat Absorbing): FS DD-G-001403, FT, Condition A, Type I, Class 2, Style B . Provide color as shown, 1/4” (6 .35 mm) thick, unless otherwise shown .

9 7. .4 HEAT STRENGTHENED Clear: FS DD-G-001403, Kind HS, Condition A, Type I, Class 1, 1/4” (6 4. mm) thick unless otherwise shown . Tinted (Heat Absorbing): FS DD-G-0011403, Kind HS, Condition A, Type I, Class 2 . Provide color as shown, 1/4” (6 .4 mm) thick unless otherwise shown .

9 7. .5 MIRROR FS DD-G-451, Type I, Class 1 or Class 2 as required, of the following quality . Provide silvering, copper backing and protective coating conforming to FS DD-M-411 . A . Quality q1 if less than 25 square feet (2 .25 sq . m) . B . Quality q2 if more than 25 square feet (2 .25 sq . m) .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.15 CONSTRUCTION STANDARDS Section 3

9.8 GRANITE The types and finishes of granite are shown on drawings . All granite being provided shall comply with the National Building Granite Quarries Association, Inc .

9 .8 1. REFERRENCE STANDARDS Design and erection of stonework shall comply with the requirements of all governing codes and regulatory agencies .

9 .8 .2 CONSTRUCTION A . Variation from Plumb: for lines and surfaces of columns, wall arises, do not exceed + 1/8 inch in 10 ft . B . Accurately cut, dress, drill, fit and finish stonework to shapes and dimensions shown on drawings and final shop and setting drawings . Cut and drill stones in shop as required for supports, anchors, ties, grab and Lewis bolts, and other inserts . Make exposed plane surfaces true in line . C . Cut external corners with 3/8 in . quirk-miter joints where shown; cut all other joints and edges square and at right angles to face, and with backs parallel to face . Make arises straight, sharp, true, and continuous at joints . D . The use of liners, properly sized and secured to stone facing, will be permitted only where shown on drawings, and final shop drawings .

9 .8 .3 INSTALLATION A . Clean stone before setting by scrubbing with fiber brushes followed by a thorough drenching with clear water . Use only mild, cleaning compounds that contain no caustic or harsh fillers or abrasive . If not thoroughly wet at time of setting, drench or sponge stone . Do not wet expansion or control joint surfaces . B . Ferrous Metals: Where stonework will contact ferrous metal surfaces which will be concealed in back-up construction (anchors, supports, structural framing and similar surfaces), apply a heavy coat of bituminous paint on metal surfaces, prior to setting stone . Do not extend coating onto portions of ferrous metal which will be exposed in the finished work . Do not apply coating to stainless steel or non-ferrous metals . C . Anchors: Set stone in accordance with the drawings and final shop drawings . Provide anchors, supports, fasteners and other attachments shown, or necessary to secure stonework in place . Completely fill holes, slots and other sinkages for anchors, dowels, fasteners, and supports with mortar during setting of stone . Set exterior stone with non-ferrous dowels, dovetails, cramps or other approved anchor system . D . Cavity Construction: Where open space between back of stone units and back-up or framing is shown, keep cavity open; do not fill with mortar or grout . Provide weep holes as shown or as detailed on final shop drawings . E . Preparation of Sub-base: Clean sub-base to remove dirt, debris, and loose particles . Saturate concrete sub-base with clean water several hours before placing setting bed . About one hour prior to placing setting bed, remove surface water . F . Joint Widths: Unless otherwise specified, make joint widths for exterior facings, copings and paving 1/4 inch .

9 .8 .4 FINISHING Soundness (hardness and density), texture, graining, color and tone, is subject to the Graphic Designer’s approval . Granite shall be sound and free from defect which will impair strength, durability or appearance . Provide stonework from single quarry sources to satisfy the total requirements of this project . Quarry and fabrication plant facilities shall be available for the Graphic Designer’s or Owner’s Representative at any time . Do not use stone units with chips, cracks, voids, stains or other defects which might be visible in the finished work .

Finishes shall be uniform throughout the exposed face and edges of the stone . Samples submitted and approved shall be used as a standard of workmanship for the final installation . Flame finish shall be a uniform rough texture without any torch lines .

9.9 LIMESTONE

9 .9 1. FURNISHING AND INSTALLING Dimension stone elements incorporated in the areas shown . Grouted joints at all stone joints, except where sealant is shown .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.16 CONSTRUCTION STANDARDS Section 3

9 .9 .2 PERFORMANCE REQUIREMENTS Fabricate and install stonework to withstand loads from thermally induced movement as well as to resist deterioration under conditions of normal use including exposure to weather, without failure .

9 .9 .3 SUBMITTALS Prior to placing orders for stonework, submit at least three (3) samples of each type of stone required showing range of natural characteristics, color, texture, and defects to be expected in the completed work . Prior to placing orders for Portland cement, provide certified test results showing compliance with requirements, including compliance with the low-alkali requirements . Submit product data and samples of each type of stonework accessory .

9 .9 .4 QUALITY INSURANCE Obtain each type from one quarry with consistent color range and texture throughout the work . All stonework shall match approved samples on file in the Architect’s office .

9 .9 .5 REINFORCEMENT AND ANCHORING MATERIALS A . Low Alkali Portland Cement: ASTM C 150, low alkali type with not more than 0 .60% water soluble alkali . Provide Type I, except Type II may be used for setting masonry during cold weather . Prior to placing orders for Portland cement, provide certified test results showing compliance with requirements, including compliance with the low-alkali requirements . Subject to compliance with requirements, provide TXI Cement Company, New Braunfels, TX, (Tel) 512-396- 4244, Type I low alkali Portland cement or equivalent as approved by Architect . B . Setting Bed Mortar and Anchoring Cement: Comply with ASTM C 270, Type M mortar mix for paving setting beds and Type S mortar mix for other stonework . Provide mix consisting of low alkali Portland Cement (ASTM C 150, Type I) gray, as specified, lime (ASTM C 207, Type S), clean sand (ASTM C 144, with no less than 100% passing a No . 8 sleeve), and water for workable mix . At exterior stonework, include Sonneborne “Hydrocide Powder” waterproofing admixture in mortar mix . 1 . Sand for Paver Slurry Bond Coat: 30-60 mesh silica sand . 2 . Admixtures for Mortar Bed: Laticrete No . 3701, and Laticrete No . 4237 for slurry bond coat, as manufactured by Laticrete International, Inc . C . Wall Ties: Corrugated AISI Type 302/304 stainless steel wall ties, 16 gauge, spaced 16” o c. . vertically and 16” o c. . horizontally . D . Dowels: AISI Type 302/304 stainless steel, minimum 1/4” diameter . E . Setting Buttons: Lead or aluminum buttons of thickness required for joint size . F . Dovetail Slots: Dovetail slots (with filler strips) fabricated from minimum 24 gage galvanized steel .

9 .9 .6 MISCELLANEOUS MATERIALS A . Pigmented Grout: Factory-prepackaged mixture of cement, fine aggregates and colorfast pigments; Bostik “Hydroment Grout” in color as selected by Architect from manufacturer’s standard colors . B . Sealer: Clear, penetrating water and oil repellent sealer suitable for exterior and interior masonry surfaces; Pro-So-Co “Stand Off Tile and Masonry Protector” . C . Pointing Mortar: Use specified setting mortar except as follows: 1 . For white pointing mortar, provide natural white sand or ground white stone meeting the specified requirements . 2 . For colored pointing mortar, provide marble, granite or other sound stone, meeting the specified requirements for sand, and matching Architect’s sample . 3 . Colored Mortar Pigments: Solomon Grind-Chem Service or Davis mortar colors; color as selected by Architect .

9 .9 7. GENERAL FABRICATION A . Fabricate as shown and as detailed on final shop drawings and in compliance with the recommendations of the applicable stone association . Cut or form accurately to shape and dimensions on final shop drawings, maintaining fabrication tolerances of applicable stone associations . Provide chases, reveals, reglets, openings and similar spaces, and features as required for contiguous work . 1 . Dress joints (bed and vertical) straight and at a 90 degree angle to face, unless otherwise shown . 2 . Joint Width: Cut to provide 3/8” nominal joint widths for exterior work, unless otherwise shown .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.17 CONSTRUCTION STANDARDS Section 3

3 . Thickness: Provide stone of the thickness shown . Saw-cut back surfaces which will be concealed in the finished work . Allow 3” clearance between back face of units and structure framing unless otherwise detailed .

9 .9 .8 INSTALLATION A . Clean stone before setting, using only mild cleaning compounds that contain no caustic or harsh fillers or abrasives . B . Clean and wash subbase for paving and thresholds . C . Execute stone work by skilled mechanics, and employ skilled mechanics, and employ skilled stone fitters at the Site to do necessary field cutting of natural stone as stone is set . D . Mortar and Grout: Mix materials with water for a homogeneous mix . Comply with admixture material manufacturer’s printed instructions . E . Set stone plumb and true and with courses level, accurately spaced, in accordance with Drawings and final shop drawings, and as necessary to secure stonework in place . Shim and adjust as required . F . Remove stone units which are broken, chipped, stained or otherwise damaged, and provide new matching units, install as specified . Where directed, remove and replace units which do not match adjoining stonework .

9 .9 .9 CLEANING A . Clean stone Type 1 not less than 6 days after completion of work, using clean water and stiff bristle brushes . Do not use wire brushes, acid type cleaning agents or other cleaning compounds with caustic or harsh fillers. Clean stone Type 1 prior to installation of inlaid wood flooring, in accordance with stone producer’s recommendations . Seal stone Type 1 exposed surfaces immediately after cleaning in accordance with sealer manufacturer’s printed instructions .

9.10 MILLWORK

9 10. 1. FABRICATION AND INSTALLATION Strictly comply with AWI standards and approved shop drawings . Provide work matching shapes, profiles and sizes indicated . Scribe work to fit with hair line accuracy . Miter and cope all wood joints and moldings . Install in longest available lengths to minimize seams and joints; no finger-jointed wood is acceptable . Securely fasten work to substrates, framing and blocking with concealed fasteners. When face fasteners are unavoidable, countersink fasteners and fill holes flush to be not noticeable after finishing . Conceal all seams in exterior panels with wood trim .

9 10. .2 TOLERANCES Do not exceed the following maximum acceptable installation tolerances, except where tighter tolerances are specified in AWI standards: • Allowable Variation from True Plumb and Level: 1/8” in 20’ • Allowable Variation from True Plane: 1/8” in 10’ • Allowable Variation from True Alignment: 1/8” in 10’ • Allowable Variation from True Flush at Joints: Joints shall be invisible after painting.

9 10. .3 WOOD FOR PAINT FINISHES Provide Pine or Poplar interior door frames, miscellaneous wood and moldings complying with AWI Premium Grade requirements . Provide solid stock; glued pieces and finger-jointed pieces are not acceptable . Provide tempered hardboard pegboard with four assorted hangers for each square foot of pegboard area .

9 10. .4 PLASTIC LAMINATE WORK Provide NEMA LD-3 laminate complying with AWI Premium Grade materials and workmanship . Provide 0 050”. horizontal grade with colors and textures as selected by Architect from industry available choices . Provide minimum 42 pound density particle board core and laminate balancing sheets .

9 10. .5 FASTENERS Provide nails, screws, and fasteners appropriate for intended use .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.18 CONSTRUCTION STANDARDS Section 3

9.11 PHOTOPOLYMER

9 11. 1. APPROVED SUPPLIERS The following are approved polymer suppliers:

Pittman 1787 Williams Drive Marietta, GA 30066 (404) 428-8000

JETT USA Corp . 1116 MacDade Blvd . P O. . Box 1387 Collingdale, PA 19023 1-800-528-1153

9 11. .2 FABRICATION Graphics to be mechanically photo-etched from original artwork and Grade 2 Braille . Graphic relief raised 1/32” from background . Graphics to be integral with the background . Individually applied and hand-spaced graphics are not acceptable .

Graphic sign panels to be permanently attached to an acrylic back-up panel ( 125”. or 250”). . Corners (square and round) with edges routed . Panel assembly to be mounted with double-sided tape and silastic adhesive .

9 11. .3 FINISHES Graphic sign panel background to be painted with a matte acrylic enamel or polyurethane type paint as required by the manufacturer . Raised graphic surfaces to be screened acrylic enamel or approved screening enamel compatible with the background finish . Braille to be the same color as the background .

9.12 PLASTICS

9 12. 1. ACRYLICS Provide acrylic plastics equivalent to “Plexiglas” manufactured by Rohm and Haas Company, in sizes as shown . Provide colors as shown, or as selected by the Graphic Designer .

9 12. .2 LAMINATES NEMA LD-3 horizontal grade, in colors and patterns shown, or as selected by the Graphic Designer . Provide one of the following:

Nevamar: Exxon Chemical Company USA Wilson Art: Ralph Wilson Plastics Company Micarta: Westinghouse Electric Corporation Textolite: Parkwood Division of General Electric Company Formica: Division of Cyanamid Corporation

9.13 LASER ENGRAVING MATERIAL

9 13. 1. MANUFACTURERS Provide micro-surfaced impact-resistant acrylic equivalent to “Lasermark” as manufactured by Rowmark in sizes shown . Provide thicknesses and colors as noted in the drawings .

Rowmark ,LLC 2040 Industrial Drive Findlay, Ohio 45840 419-425-8974 www .rowmark com.

Or approved equal .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.19 CONSTRUCTION STANDARDS Section 3

9.14 RIGID PVC BOARD (THERMOPLASTIC SHEET) (Sintra) Thermoplastic (PVC) sheet shall be of thickness and sizes shown, formed to profiles and shapes indicated on the drawings . All exposed edges shall be filed smooth and finished with proper grit .

9 14. 1. ADHESIVES Where thermoplastic (PVC) sheet is to be bonded to itself or other substrates solvents or solvent- dispersed adhesives such as THF (Tetra Hydro Furan), Cyclohexanone, or MEK (Methyl Ethyl Ketone) based types shall be used . Prior to adhesive applications both surfaces to be joined must be clean, degreased and dry . The pretreatment procedure shall consist of wiping surfaces with isopropyl alcohol with non-colored cloth and allowing surfaces to properly dry .

9 14. .2 COATINGS All surfaces shall be prepared to receive coatings or surface finishes according to manufacturer’s latest for surface preparation and application but in no case less than one (1) applicable primer coat and two (2) final full coats . All finished surfaces shall be uniform .

9 14. .3 OTHER Thermoplastic polyvinyl chloride (PVC) sheet shall be Komacel as manufactured by Komerling USA, Inc ., 210 Summit Ave ., Montvale, NJ 07645, (800) 253-3363 .

9.15 ROUGH CARPENTRY

9 15. 1. LUMBER Provide Construction Grade or No . 2 Grade lumber complying with PS 20 . A. Decay Treated: Provide above ground lumber in contact with roofing, flashing, sheet metal, masonry concrete, damp-proofing and waterproofing that is pressure-treated with waterborne preservatives complying with AWPB LP-2 and AWPA C2 . Dry lumber to maximum moisture content of 19% after treatment . B . Fire-Retardant Treated: For all interior blocking, provide lumber which is UL labeled fire- retardant FR-S . Dry lumber to maximum moisture content of 19% after treatment .

9 15. .2 PLYWOOD Provide APA trademarked Exposure 1 C-D veneer performance rated plywood panels with span rating for span indicated if thickness is not shown . Provide UL listed Class A fire-retardant treated plywood for telephone and electrical mounting panels and all interior plywood .

9 15. .3 PLYWOOD BACKING PANELS Provide APA trademarked, UL labeled, fire-retardant treated, C-D Plugged Exposure 2 panels not less than 5/8” thick and complying with PS 1. Provide treatment that yields a flame spread rating of not more than 25 when tested according to ASTM E84 .

9 15. .4 FASTENERS Provide nails, screws, and fasteners appropriate for intended use .

9 15. .5 WOOD FOR PAINT FINISH Provide Pine or Poplar interior door frames, miscellaneous wood and moldings complying with AWI Premium Grade requirements . Provide solid stock; glued pieces and finger-jointed pieces are not acceptable . Provide tempered hardboard pegboard with four assorted hangers for each square foot of pegboard area .

9.16 SIGN FOAM

9 16. 1. CHEMICAL PROPERTIES Polyether Polyurethane

9 16. .2 STRENGTH Sign Foam exhibits an excellent strength to weight ratio because of its high strength polymer and cellular structure .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.20 CONSTRUCTION STANDARDS Section 3

9 1. .3 DURABILITY Sign foam is very stable . It will not corrode and it is closed cell and impervious to organic decay . It is closed cell and waterproof . Note: Sign Foam is sensitive to ultraviolet light and should always be properly finished with an opaque paint .

9 16. .4 CHARACTERISTICS AND FINISHING PROPERTIES Fabrication and finishing techniques of Sign Foam are similar to those of wood products .

9 16. .5 FIRE RETARDANT Precautions similar to those used for protecting wood products from fire should be followed . Although much less flammable than wood or acrylics, Sign Foam will only char on the outside surface and will not melt . Note: For projects requiring thorough documentation of Sign Foam’s testing performance, such as governmental projects, information is available from Sign Arts upon request .

9 16. .6 APPROVED SUPPLIER Southeastern Sign Supply, 6003 Chapel Hill Road, Suite 177, Raleigh, NC 27607, (800) 283-1722 .

9.17 STAINLESS STEEL

9 17. 1. ALLOYS Provide alloys 302 or 304 established by American Iron and Steel Institute (AISI) unless shown otherwise .

In addition, comply with the following requirements: A . Extrusions: ASTM A 167 B . Bar Stock: ASTM A 267 C . Plate: ASTM A 167 D . Tubing: ASTM A 269 E . Castings: ASTM A 296, iron-chromium-nickel alloy

9 17. .2 FINISHES Unless otherwise shown or specified, provide stainless steel finishes to match Owner approved samples, and as follows (AISI designations): A . Matte: No . 2D B . Directional/Bright: No . 4 C . Directional/Satin: No . 6 D. Directional/Highly Reflective: No. 7 E. Non-directional/Mirror Reflective: No. 8

9.18 STEEL

9 18. 1. MATERIALS Structural Steel Shapes and Plates: ASTM A 36

Steel Plate for Cold Forming: ASTM A 283, Grade C

Hot Rolled Steel Bars: ASTM A 108, Grade as selected by fabricator .

Steel Pipe: ASTM A 53, Type E, F or S, at fabricator’s option, Grade A, black finished unless shown as galvanized, standard weight (Schedule 40) unless otherwise shown or specified .

Hot-Formed Rectangular Steel Tubing: ASTM A butt welded, cold finished and stress relieved .

Cold-Drawn Steel Tubing: ASTM A 512, sunk drawn, butt welded, cold finished and stress relieved .

Steel Sheet for Cold Forming: ASTM A 569, hot-rolled sheet steel of commercial quality, pickled and oiled, free of defects which would impair the work .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.21 CONSTRUCTION STANDARDS Section 3

Galvanized Steel Sheet: ASTM A 526, commercial quality .

9 18. .2 FINISHES Chrome Plated: ASTM B 456, Type SC-2 over a coating of copper and nickel . Provide a bright polished finish unless otherwise shown .

Primer: Provide one of the following, unless steel indicated to receive galvanized finish: 1 . Dimetcote No . 4, Amercote Corporation 2 . Tnemec Zinc 92, Tnemec Company 3 . Carbo Zinc II, Carboline Company

Baked Enamel Finish: Provide manufacturer’s standard baked acrylic enamel finish, in colors specified by the Graphic Designer .

9.19 STONEWORK The stonework requirements shown by the details are intended to establish basic dimensions of units or modules, pro files, and sight lines . Within these limitations, the Signage Contractor is responsible for maintaining the visual design concept as shown, for the entire stonework system and to make whatever modifications of, and additions to, the details as may be required to fulfill the performance requirements .

Design and erection of stonework shall comply with the requirements of all governing codes and regulatory agencies .

9 19. 1. FABRICATION A . Allow for expansion and contraction within the limits of the joint material when cutting for anchorage devices . B . Provide greater stone thicknesses than shown where thickness shown is insufficient for the sizes of where extent of cut-outs shown decreases effective strength of the remaining material, or for proper and sufficient anchorage, suitable and adequate bearing areas or surfaces . C . The use of lines properly sized and secured to stone facing will be permitted only where shown on construction and final shop drawings . D . Do not use stone units with chips, cracks, voids, stains or other defects which might be visible in the finished work . E . Where open space between back of stone units and back-up or framing is shown, keep cavity open; do not fill with mortar or grout . Provide weep holes as shown or as detailed on final shop drawings . F . Make joint widths, unless otherwise shown as follows: for exterior facing and coping, 1/4”, and exterior paving, 1/4” . G. Immediately after initial cleaning of stone floors, counters and other horizontal installation, seal stone with weatherproof seal . At final cleaning, remove any accumulation of stains, dust, dirt and any other defects . Apply a final coat of weatherproof seal . Use one of the following, or approved equal: 1 . Prosoco 2 . HMK

9 19. .2 INSTALLATION A . Stonework should be executed by skilled mechanics, and employ skilled stone fitters at the site for necessary field cutting as stone is set . B . Where stonework will contact ferrous metal surfaces, apply a heavy coat of bituminous paint on metal surfaces, prior to setting stone . Do not apply coating to stainless steel or non-ferrous metals .

9.20 ZINC / PHOTOENGRAVING

9 .20 1. MATERIAL Provide alloy #Z450

9 .20 .2 FABRICATION Graphics to be mechanically photo-etched from original artwork and Grade 2 Braille . Graphic relief

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.22 CONSTRUCTION STANDARDS Section 3

raised 1/32” from background . Graphics to be integral with the background . Individually applied and hand-spaced graphics are not acceptable . Panel assembly to be mounted with double-sided tape and silastic adhesive .

9 .20 .3 FINISHES Graphic sign panel background to be painted with a matte acrylic enamel or polyurethane type paint as required by the manufacturer . Raised graphic surfaces to be screened acrylic enamel or approved screening enamel compatible with the background finish . Braille to be the same color as the background .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.23 CONSTRUCTION STANDARDS Section 3

10.0 MISCELLANEOUS PRODUCTS

10.1 ADHESIVES

10 1. 1. FOAM TAPE 1/16” (1 6. mm) thick, double-faced, white pressure sensitive urethane foam adhesive tape, one of the following: A . 3M Company: No . 4016 or AL4432YEAom9576 B . Spectape of Texas: No . ST1132

10 1. .2 FILM TAPE 4 mil (0 1. mm) thick, double-faced pressure sensitive film tape, one of the following: A . 3M Company: No . 415 B . Macbond: No . SB1786 or No . 0530-IS-0303-KA1100

10 1. .3 SILICONE FS TT-S-001543, Class A, one of the following: A. General Electric: Silicone Sealant #1200 B. Dow Corning: Building Sealant #781

10 1. .4 EPOXY Two component thermosetting epoxy adhesive with 100% solids content, one of the following: A . Miracle Adhesives: No . NP-428 B. Hughson Chemicals: Chemlok #304

10.2 AWNING MATERIAL(S)

10 .2 1. FABRIC Provide flame retardant awning material equivalent to “Sunbrella” 8600 series, as manufactured by Glen Raven Mills, Inc . . Provide sizes and colors as shown or as selected by the Graphic Designer .

10 .3 SILK SCREEN INKS All inks, paints and lacquers required for silk screened or imprinted surfaces or other specified surfaces, shall be a type made for the surface material on which it is to be applied and recommended by the manufacturer of the ink or paint . Exact identification of all ink and paint shall be noted on the shop drawings, together with data describing the method of application and if other than “air”-dried drying . All silk screen inks shall be made by a manufacturer with experience in production and consistency of such inks for the purposes and surfaces involved .

10 .3 1. GENERAL REQUIREMENTS All screen printing specified shall be executed from photo screens prepared from reproductions of the copy specified .

The Signage Contractor shall submit full-size showings of foundry to be used to the Graphic Designer for approval .

All above work is to be included in this contract . No hand-cut screens will be accepted . Prime coats or other surface pre-treatment, where recommended by the manufacturer for inks, paints or lacquers, shall be included in the work (and noted on the shop drawings) as part of the finished surface work at no additional cost to the Owner .

All screen printing shall be executed in such a manner that all edges and corners of finished letterforms and graphic devices are true and clean . Letterforms with rounded positive or negative corners, edge build-up or bleeding, etc ., will not be accepted .

No paint, ink or lacquer that will fade, discolor or delaminate as a result of proximity to UV light source or heat there from shall be used . All inks, paints and lacquers shall be evenly applied and without pinholes, scratches, orange peeling, application marks, etc . Rear-illuminated panels containing the above or other defects which cause light leaks in surface areas specified to be covered will not be accepted . Workmanship in connection with finishes and formations of letters and/or graphics shall conform to the standards of the trade and shall be acceptable to the Graphic

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.24 CONSTRUCTION STANDARDS Section 3

Designer .

10 .3 .2 MANUFACTURERS Provide silk screen inks in colors and sheen as specified and manufactured by one of the following or approved equal:

Naz-Dar Company Chicago, Illinois

Wornow Products Department Dexter Corporation Industry, California

Colonial Printing Ink Company East Rutherford, New Jersey

10.4 VINYL This specification defines basic materials and fabrication methods for markings/graphics to be used by the Signage Contractor for cut out graphics . No deviation from these specifications is permissible without the written approval of the Owner or Graphic Designer . The Signage Contractor shall certify that all markings/graphics conform to these specifications, and will be replaced without additional cost to the Owner if they fail to meet this requirement .

10 .4 1. NON-REFLECTIVE The marking film used shall be 3M ScotchCal™ brand film, series 220 . The finished emblems shall be pre-masked .

10 .4 .2 REFLECTIVE The marking film shall be 3M ScotchLite™ reflective sheeting, series 680, 580 or 480, or others as approved by the Owner or Graphic Designer . The Signage Contractor shall verify all City and State traffic codes for grade of reflective vinyl, and shall use high intensity vinyl when required by code. If the codes do not specify, then engineering grade vinyl is acceptable .

10 .4 .3 PRESSURE SENSITIVE Cut vinyl to be 1 8. mil (0 .89) thick, pre-spaced and pre-aligned on transfer paper . Provide vinyl graphics in colors and type styles shown .

10 .4 .4 LETTERFORMS Size: Letterforms shall be as shown or indicated on the drawings, and shall be the only typography used . Letter size for the appropriate sign types shall be as shown on the drawings and graphic layouts . Alternate letterforms and letter size will not be accepted .

Spacing: Letter spacing shall be at the standard optical-spacing . Spacing between words shall equal the horizontal dimension of a lower-case “m” for the size of the copy being used . The Signage Contractor shall furnish to the Graphic Designer for approval, a full-size spacing pattern for each message specified . No work shall be executed from spacing patterns not approved by the Graphic Designer .

10 .4 .5 GENERAL REQUIREMENTS A . Color, copy and logotype rendition shall be approved by Owner or Graphic Designer prior to production . B . Graphics shall be weather-resistant and shall not be affected by oil, water, salt spray or alcohol . C . Where specifically noted, provide reverse cut copy for application to glass . All other applications shall be “correct-reading” on the exterior of glass . D . Size, colors and shape of markings to be fabricated in accordance with 3M Product Specs for each item . Marking shall be in accordance with 3M Instruction Bulletin No . 5 . E . All cut edges (i e. . laser, kiss cut, guillotined, etc .) shall be smooth and free of ragged areas . F . Markings shall be packaged in substantial cartons which will protect against physical damage in shipping and handling and against dirt or moisture contamination .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.25 CONSTRUCTION STANDARDS Section 3

10.5 SCOTCHPRINT® ­ 10 .5 1. APPLICATION Follow 3M product bulletin and instruction bulletins in their entirety . Provide vinyl in colors, textures and patterns selected by Designer from industry available colors .

10 .5 .2 SCOTCHPRINT® FILM SERIES 8620 Method of Decoration: 8620 base film with matte overlaminate 8911 or 8931 and 8700 toners . Base Film: Marking Film #8620 White, Product Bulletin 8000/8600, Instruction Bulletin 4.7. Application Tape: 3M Application Tape #SCPM-3, Instruction Bulletin 4.3. Overlaminating Film: ScotchPrint Film #8911, Product Bulletin 8000, Instruction Bulletin 4.8; ScotchPrint #8931, Product Bulletin 8000, Instruction Bulletin 4.8. Related Literature: ScotchPrint Toners, Product Bulletin 8700; Surface Preparation (Non-Vehicular), Instruction Bulletin 5 1;. Application Procedures ControlTac Plus (Corrugated) Instruction Bulletin 5 4;. and ControlTac Plus (Flat and Curved), Instruction Bulletin 5 .6; Removal Procedures, Instruction Bulletin 6 5.

10 .5 .3 SCOTCHPRINT® FILM SERIES 8640 Method of Decoration: 8640 base film with matte overlaminate 8911 or 8931 and 8700 toners . Base Film: Marking Film #8640 White, Product Bulletin 8000/8600, Instruction Bulletin 4.7. Application Tape: 3M Application Tape #SCPM-3, Instruction Bulletin 4.3. Overlaminating Film: ScotchPrint Film #8911, Product Bulletin 8000, Instruction Bulletin 4.8; ScotchPrint #8931, Product Bulletin 8000, Instruction Bulletin 4.8. Related Literature: ScotchPrint Toners, Product Bulletin 8700; Surface Preparation (Non-Vehicular), Instruction Bulletin 5 1;. Application Procedures ControlTac Plus (Corrugated) Instruction Bulletin 5 4;. and ControlTac Plus (Flat and Curved), Instruction Bulletin 5 .6; Removal Procedures, Instruction Bulletin 6 5.

10 .5 .4 MANUFACTURING Markings must be manufactured using materials and procedures described in the appropriate Product and Instruction Bulletins .

10 .5 .5 GRAPHICS INSTALLATION Surface preparation and application of markings must use the materials, methods and tools described in the appropriate Product and Instruction Bulletins .

10 .5 .6 TECHNICAL ASSISTANCE Any technical questions relating to the 3M products referred to in the specification should be directed to 3M Commercial Graphics Technical Service at 800-328-3908 .

10 .5 7. MANUFACTURERS 1 . Vomela 800-240-9279 2 . Ariston 800-526-4901 3 . Wace 212-661-5600

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.26 CONSTRUCTION STANDARDS Section 3

11.0 PAINTS AND COATINGS

11.1 ACRYLIC POLYURETHANE

11 1. 1. GRIP GARD® Grip Gard ® approved automotive type paint systems manufactured by Akzo Wyandotte or approved equal .

Signage Contractor shall be approved by the manufacturer for application of paint or coating system .

Signage Contractor shall apply paint system strictly observing the manufacturer’s recommendations regarding application technique using internal mix conventional spray equipment . Apply as to achieve 100% coverage at the rate of 150 square feet per gallon or as manufacturer recommends .

Overall appearance must match specified color and pattern of submitted sample . Pattern and sheen should be uniform . If primer is visible through paint when inspected, paint coverage will be considered incomplete and disapproved by the Owner or Graphic Designer . Should the Owner or Graphic Designer disapprove of the applied coating, the Signage Contractor shall bear all costs to complete paint finish .

11 1. .2 MATTHEWS® Matthews acrylic polyurethane enamels as manufactured by the Matthews Paint Company, or approved equal . Contractor shall apply paint system strictly observing manufacturer’s recommendations regarding application and mixing . Apply as to achieve 100% coverage at a rate of 150 square fee per gallon or as manufacturer recommends .

11.2 BITUMINOUS PAINT Cold-applied asphalt mastic for isolating dissimilar metals .

11.3 ENAMELS Provide high quality sign lettering paints; colors to match those specified and applied per manufacturers instruction regarding application techniques . Apply to achieve 100% coverage at manufacturers recommended rate of coverage per gallon .

Use paints as manufactured by the following, or approved equal: Ronan Chromatic Paint One-Shot Lettering Enamel

11.4 PORCELAIN ENAMELS (Vitreous Enamel)

11 .4 1. SUBSTRATE Enameling grade, reduced carbon, tension leveled steel . Minimum 18 gauge thickness . Pare steel by means of pickling or etching prior to application of ground coat .

11 .4 .2 PORCELAIN Frit of mineral-content glass to be combined with appropriate oxides to match specified colors . Additives applied to ensure proper stability, adhesion, color consistency and gloss .

11 .4 .3 IMAGING Images are to be provided in colors and sizes specified in design drawings . Silk screening or photosensitized porcelain slip are the only acceptable image application procedures . A white under- printing is to be applied prior to color image application .

11 .4 .4 INSTALLATION Porcelain panels are to be permanently attached to structurally supporting substrate . Exterior grade plywood, aluminum honeycomb or other approved stiffening materials can be used .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.27 CONSTRUCTION STANDARDS Section 3

11.5 POLYURETHANE ENAMEL Provide an aliphatic polyurethane enamel with ultraviolet inhibitors, lightfast, weather abrasions and wear resistant . Provide one of the following: A . Chemglaze: Hughson Chemical Division, Lord Corporation B . Imron: DuPont de Nemours & Company

11.6 POLOMYX SYSTEM The Polomyx system shall be applied by a Signage Contractor who has completed the Polomyx Training Program available through authorized distributors . The Signage Contractor shall apply Polomyx strictly observing manufacturer’s specifications . Information is available from Polomyx Industries, or an authorized distributor . Variegated surface film materials manufactured by:

Polomyx Industries, Inc . Wilmington, MA 01887

11 .6 1. APPLICATION Drywall/Concrete: Polomyx #202 Wood/Plaster: Polomyx #208 Steel: Polomyx #210 Galvanized Steel: Polomyx #212 Barrier Coat: Polomyx #214 Fire Rating: ASTM E84 (811a)

11 .6 2. DURABILITY TESTS Accelerated Aging: ASTM 623, ASTM D82 Color Fastness: FED-STD-141, method 4561 Stain Resistance: ASTM D1308 Scrubability: ASTM D2486 Washability: FED-STD-141, method 6141 Odor: ASTM D11 33, DN Test Self Lifting: FED-STD-141, method 6252 Freeze/Thaw: ASTM D2337 Stability Strippability: ASTM F793, Section 7 17.

11 .6 3. APPEARANCE Overall appearance must match specified color and pattern as specified in contract documents . If primer is visible through Polomyx when inspected, Polomyx coverage will be considered incomplete and disapproved by the Owner or Graphic Designer . Should the Owner or Graphic disapprove of the applied coating, the Signage Contractor shall bear all costs to complete Polomyx finish .

11.7 TNEMEC PAINT

11 7. 1. REFERRENCE STANDARDS Steel Structures Painting Council (SSPC) 1 . SSPC-Vis 1 Pictorial Surface Preparation Standards for Painting Steel Structures 2 . SSPC-SP2 Hand Tool Cleaning 3 . SSPC-SP3 Power Tool Cleaning 4 . SSPC-SP6 Commercial Blast Cleaning 5 . SSPC-PA2 Measurement of Dry Paint Thickness with Magnetic Gauges

American Society for Testing and Materials (ASTM) 1 . ASTM D 522 Mandrel Bend Test of Attached Organic Coating, Test Method B-Cylindrical Mandrel Test 2 . ASTM B 117 Method of Salt Spray (Fog) Testing 3 . ASTM D 4060 Test Method for Abrasion Resistance of Organic Coatings by the Taber Abraser 4 . ASTM D 3359 Method for Measuring Adhesion by Tape Test

Federal Standards and Test Methods 1 . Federal Specification TT-P-86d, Types I and II .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.28 CONSTRUCTION STANDARDS Section 3

11 7. .2 MATERIALS Products manufactured by the Tnemec Company, Inc ., P O. . Box 4112749, Kansas City, Missouri 64141, are used herein to establish quality and type . Products of other manufacturers may be submitted with supporting test data showing performance characteristics, which meet or exceed those standards set forth herein .

Shop Primer: 10-99 Tnemec Primer

11 7. .3 FABRICATION PRIMING Shop paint all steelwork using the following systems: 1 . Surface Preparation: SSPC-SP6 Commercial Blast Cleaning 2 . Application: Follow coating manufacturer’s printed directions . 3 . Material: 10-99 Tnemec Primer 4 . Number of Coats: One 5 . Dry Film Thickness: 2 0. mils minimum 6 . Volume Solids: 55 0. ± 2 0%. minimum

11 7. .4 INSPECTION Visually evaluate surface preparation by comparison with pictorial standards in accordance with SSPC-Vis 1 . Measure dry film thickness with a magnetic film thickness gauge in accordance with SSPC-PA2 . Visually inspect dried film for runs, sags, dry spray, overspray, imbedded particles and missed areas . Repair defective or damaged areas in accordance with Section 0 0. .3 above .

11 7. .5 STACKING AND SHIPPING Keep primed steel off the ground by placing on wooden supports and keep members from touching each other by using wooden separators for stacking . Take measures to avoid damaging prime coat while stacking, loading or unloading and use wooden protectors to prevent damage from chain or cable cinches .

11 7. .6 FIELD TOUCH-UP PAINTING Prepare and coat welds, fasteners, burned and abraded areas in accordance with Section 0 0. .3 above .

11 .8 TRANSLUCENT COATING Provide colors shown or selected by Graphic Designer by the following: A . Grip-Flex: Wyandotte Paint Products Company

11.9 POLYVINLIDENE FLUORIDE (PVDF) RESIN

11 .9 1. PRODUCT NAME KYNAR 500®

11 .9 .2 MANUFACTURER ATOFINA Chemicals, Inc . Technical Polymers 2000 Market Street Philadelphia, PA 19103-3222 (800) 596-2750

11 .9 .3 PRODUCT DESCRIPTION BASIC USE KYNAR 500 resin is a fluoropolymer –polyvinylidene fluoride (PVDF) – that is used as the major vehicle (base resin) in liquid coatings formulated by leading paint manufacturers . KYNAR 500 resin is marketed under a license agreement . When formulated into a coating composition which, according to the license agreement, contains a minimum of 70% by weight of KYNAR 500 resin, the resultant coatings exhibit superior: • Color retention • Chalk resistance • Corrosion resistance

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.29 CONSTRUCTION STANDARDS Section 3

• Flexibility • Stain resistance • Overall exterior durability

Liquid coatings containing KYNAR 500 resin are factory-applied to properly cleaned, pretreated and primed metal substrates and then oven baked . Metal substrates most commonly coated with KYNAR 500 based finishes are aluminum, hot dip galvanized . G-90, steel and 55% aluminum-zinc alloy coated steel .

KYNAR 500 based coatings are typically applied to building components such as metal siding and roofing, storefront extrusions, curtain walls, louvers, skylights and other miscellaneous metal trim and extrusions . Components can be either post formed from pre-coated coil stock or spray coated after fabrication . Special KYNAR 500 based coating formulations that exhibit increased abrasion or corrosion protection are available through the KYNAR 500 licensees .

COMPOSITION & MATERIALS KYNAR 500 resin is a high molecular weight homopolymer of vinylidene fluoride. Finishes based on KYNAR 500 resin are formulated by the licensed formulators and contain, in addition to KYNAR 500 resin, solvents and high quality pigments . These high quality coating systems have a proven history when exposed to severe ultraviolet radiation for extended periods (over 33 years) of time . To insure that the formulation being supplied contains KYNAR 500 resin manufactured by ATOFINA Chemicals, Inc ,. a letter of certification from the licensee is recommended .

COLOR Each of the KYNAR 500 licensees have established their own standard colors . Special colors, including metallics and exotics, are subject to approval by the licensees; however, a broad range of brighter colors are now available .

TEXTURES Textured finishes based on YK NAR 500 resin are now available through the KYNAR 500 licensees .

LIMITATIONS KYNAR 500 coatings cannot be field applied . KYNAR 500 finishes are limited to application on the following substrates: • Aluminum • Hot dipped galvanized, G-90, steel • 55% aluminum-zinc alloy coated steel

Application to hot or cold rolled steel or any other structural steel product is not recommended . Spray application of KYNAR 500 coatings is generally limited to aluminum substrates only . All KYNAR 500 finishes must ­be applied by an approved applicator .

11 .9 .4 TECHNICAL DATA APPLICABLE SPECIFICATIONS American Architectural Manufacturers Association (AAMA) • AAMA 605.2-92 - High Performance Organic Coatings on Architectural Aluminum Extrusions and Panels • AAMA 610.1 - Cleaning and Maintenance of Painted Aluminum Extrusions and Curtain Wall Panels

American Society for Testing & Materials (ASTM) • ASTM B117-95 - Operating Salt Spray (Fog) Apparatus • ASTMB244-79-Measurement of Thickness of Anodic Coatingson Aluminum and of Other Non- conductive Coatings on Nonmagnetic Basis Metals with Eddy-Current Instruments • ASTM D523-89 - Specular Gloss • ASTM D968-93 - Abrasion Resistance of Organic Coatings by Falling Abrasive • ASTM D1308-87 - Effect of Household Chemicals on Clear and Pigmented Organic Finishes • ASTM D2244-93 - Calculation of Color Differences From Instrumentally Measured Color Coordinates • ASTM D2247-94 - Testing Water Resistance of Coatings in 100% Relative Humidity • ASTM D2248-93 - Detergent Resistance of Organic Finishes • ASTM D2794-93 - Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact)

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.30 CONSTRUCTION STANDARDS Section 3

• ASTM D3359-95a - Measuring Adhesion by Tape Test • ASTM D3363-92a - Film Hardness by Pencil Test • ASTM D4214-89 - Evaluating the Degree of Chalking of Exterior Paint Films • ASTM D4585-92 – Testing Water Resistance of Coatings Using Controlled Condensation

Architectural Spray Coaters Association (ASCA) - ASCA 96 – Voluntary Specification for Superior Performance of Organic Coatings on Architectural Aluminum Curtain Wall Extrusions and Miscellaneous Aluminum Components

National Coil Coaters Association (NCCA) - NCCA Publication Coil Coated Metal Building Panels- Care and Maintenance

PHYSICAL/CHEMICAL PROPERTIES Property Performance Color uniformity Meets or exceeds specification Specular gloss, ASTM D523 Medium gloss Dry film hardness, ASTM D3363 Meets or exceeds specification Dry film adhesion, ASTM D3359 No adhesion loss Wet film adhesion, ASTM D3359 No adhesion loss Boiling water adhesion, ASTM D3359 No adhesion loss Impact resistance, ASTM D2794 No cracking or adhesion loss Abrasion resistance, ASTM D968 Meets or exceeds specification Muriatic acid resistance, ASTM D1308 No effect Mortar resistance No effect Nitric acid resistance Meets or exceeds specification Detergent resistance, ASTM D2248 No effect Humidity resistance, ASTM D2247 or D4585 Meets or exceeds specification Salt spray resistance, ASTM B117 Meets or exceeds specification South Florida weathering conditions, ASTM D2244 Meets or exceeds specification Color retention, ASTM D2244 Meets or exceeds specification Chalk resistance, ASTM D4214 Method D659 Meets or exceeds specification Gloss retention, ASTM D523 Meets or exceeds specification Erosion resistance, ASTM B244 Meets or exceeds specification

11 .9 .5 INSTALLATION Coatings based on KYNAR 500 resin are coil coated or spray applied to metal substrates that have been cleaned, pretreated and primed according to the specifications of the licensed formulator . The entire system is applied in the factory and is oven baked . Total overall dry film thickness of the coating system, including primer, is generally 0.8 – 1.3 mil (0.02 – 0.03 mm). However, certain KYNAR 500 coating systems may be specified that require thicker overall dry film thicknesses for increased corrosion protection or increased color stability for metallic or exotic colors . Consult a KYNAR 500 licensee for guidance regarding thicker formulations .

The flexibility of the PVDF coating enables post-forming by roll forming or break press methods. Components such as windows, storefronts, louvers and skylights are usually spray coated after fabrication . Applicators of finishes based on YK NAR 500 resin must be approved by the licensed manufacturer supplying the coating .

11 .9 .6 AVAILABILITY AND COST AVAILABILITY Finishes based on KYNAR 500 resin are available from ATOFINA Chemicals, Inc . KYNAR 500 licensees .

A list of the licensees may be obtained from ATOFINA Chemicals, Inc . Building components coated with finishes based on YK NAR 500 resin are available from most manufacturers of metal building components . Lists of component suppliers and spray applicators are available from ATOFINA Chemicals, Inc .

COST Specific prices of metal building components coated with YK NAR 500 finishes are available from firms supplying the desired building component .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.31 CONSTRUCTION STANDARDS Section 3

11 .9 7. WARRANTY For information on warranties consult with a KYNAR 500 licensee and the metal building component supplier .

11 .9 .8 MAINTENANCE Finishes based on KYNAR 500 resin are virtually maintenance-free and nonstaining . Due to the surface characteristics, mortar, plaster, etc . will not adhere nor stain the surface . If a cleaning procedure is required, refer to AAMA Specification 610 1. or NCCA Publication Coil Coated Metal Building Panels – Care and Maintenance as a guide. However, in all cases, the licensed formulator of record should be consulted . Surface imperfections or minor scratches can be touched-up using a coating recommended by the KYNAR 500 licensee . KYNAR 500 coatings can be used in conjunction with conventional sealants and caulking compounds . Always consult the sealant or caulking manufacturer for specific recommendations .

11 .9 .9 TECHNICAL SERVICES Complete technical information and literature is available from KYNAR 500 licensees and ATOFINA Chemicals, Inc .

For additional technical support, ATOFINA Chemicals, Inc . maintains a staff of Architectural Representatives throughout the country .

11 .9 10. FILING SERVICES • Architects’ First Source for Products • MANU-SPEC®

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.32 CONSTRUCTION STANDARDS Section 3

12.0 ELECTRICAL The work covered by this section shall include all labor, equipment, supplies and materials necessary for the installation of the complete electrical system as shown or indicated on the accompanying plans and specified herein .

Electrical work shown or implied on the construction drawings, and discussions hereinafter shall include the purchase, fabrication, installation and connection of electrical apparatus for the appropriate signage elements as part of the Owner’s contract .

It is the intent of these documents that the entire electrical installation shall be complete in every respect and any minor items, omitted but obviously necessary to accomplish this intent, shall be furnished and installed .

12.1 CODES, REGULATIONS AND STANDARDS All local fees, permits and services of inspection authorities shall be obtained and paid for by the Signage Contractor . The Signage Contractor shall cooperate fully with the local utility company with respect to their services .

The electrical installation shall be in compliance with the requirements of the latest edition of the National Electrical Code, O .S .H .A ., and the rules and regulations of the power company supplying power to the building or facility .

The electrical installation and the Signage Contractor shall comply fully with all City, County, and State laws, ordinances and regulations applicable to electrical installations as identified by this contract .

It shall be understood during the bidding process that the power source for all electrified signs shall be 277 volts .

It is the intent of these specifications to establish quality and performance standards of materials and equipment installed, hence, specific items are identified by manufacturer, trade name and catalog designation where possible .

Should the Signage Contractor propose to furnish materials and equipment other than those specified as permitted by the “or approved equal” clauses, he shall submit as a separate request .

12.2 PROGRESS OF WORK The Signage Contractor shall not do any cutting, channeling, chasing or drilling of unfinished masonry, tile, etc ., unless he first obtains permission from the Owner or Owner’s Representative . If permission is granted, the Signage Contractor shall perform this work in a manner approved by the Owner or Owner’s Representative .

The work shall be carefully laid out in advance . Where cutting, channeling, chasing or drilling of floors, walls, partitions, ceilings or other surfaces is necessary for the proper installation, support, or anchorage of raceway, outlets or other electrical equipment, the work shall be carefully done . Any damage to the building, piping, equipment or any defaced finish plaster, woodwork or metal work shall be repaired by skilled mechanic of the trades involved at no additional cost to the Owner .

The Signage Contractor shall coordinate his work so as to conform to the progress of the work of other trades and shall complete the entire installation as soon as the condition of the building or project area will permit . Any cost resulting from defects or delay of work performed under this section shall be borne by the Signage Contractor .

The Signage Contractor shall keep a separate set of electrical drawings at the job site and record all changes and revisions in red color . At completion of the job, the Signage Contractor shall return all copies of the drawings including all changes and revisions, to the Owner and Graphic Designer .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.33 CONSTRUCTION STANDARDS Section 3

12.3 TRENCHING AND BACK-FILLING Verify locations of all existing structures and/or underground utilities prior to trenching and, if damaged by the Signage Contractor, replace immediately in an approved manner at no expense to the Owner .

The Signage Contractor shall be responsible for all trenching and backfilling in connection with the electrical work . Earth is to be backfilled in thin layers, compacting and tamping each layer in accordance with applicable requirements of site work division of the project specification . Exercise necessary caution such as removal of all rocks, debris, etc ., from the bottom of the trench and from the backfill material so as to avoid damage to the wiring and/or conduit runs .

When trenching is done through specially treated areas, such as paving, paving tiles, black-top, etc ,. the Signage Contractor shall be responsible for restoring the surface to its original condition, and in a manner as approved by the Owner and the Owner’s Representative . Repair any trenches where settlement occurs, and restore the surface for the period of one (1) year after final acceptance of the work .

12.4 LIGHTING Furnish and install all lighting equipment described in the specifications and shown on the drawings . Lighting equipment shall be installed complete, including suspensions of proper lengths, sockets, holders, reflectors, ballasts, lamps, etc., all wired, assembled and ready for operation. All fixtures should straight and true with reference to sign supporting structural members . Before final acceptance, adjust and direct all fixtures as instructed by the Graphic Designer .

All lighting fixtures shall bear the U .L . label for its application, be free of light leaks, warps and dents . When utilizing ballasts, they shall be designed and constructed so that the ballast case temperature will not exceed the U .L . 90° Centigrade limit in a 25° Centigrade ambient . All fixtures requiring internal illumination shall illuminate evenly without “hot spots ”.

12 .4 1. FLUORESCENT TUBES Provide standard 800 MA daylight white, high output fluorescent tubes for the sign types which require it . Lengths and sizes of tubes shall be as specified on the drawings and as required by standard fabrication techniques, but shall cause no light leaks or dark spots .

12 .4 .2 NEON TUBES Provide 15 mm neon tubing in colors as specified on the drawings for the sign types which require it . Neon tubing spacing should be no more than 1/4” between ends of tubes . Neon tubes should be bent according to all standards to allow for continual lighting with no leaks in the glass, crimps, or broken sections .

Neon tubing shall utilize the proper transformer, and remote transformers will be provided as required by the Owner or Graphic Designer . A . Signage Contractor will verify the electrical requirements, either 110v or 220v, and provide the required transformer for the neon . B . Neon and transformers will not buzz . If the neon is buzzing, the Signage Contractor will be responsible for its correction .

12.5 GROUNDING All electrical neutral conductors, raceways and non-current carrying parts of electrical equipment and associated enclosures shall be grounded in accordance with the National Electrical Code (N .E C. .) . This shall include neutral conductors, conduits, supports, cabinets, boxes, ground , etc . A . The neutral conductor shall be grounded at one (1) point only: its transformer ground source . The neutral ground source shall be the nearest continuous, metallic, cold water pipe within the building . B . The neutral conductor shall be connected from the service to the neutral ground source by a continuous (unspliced) Class B stranded copper conductor installed in rigid conduit . The connection to the neutral ground source shall ground the conductor and associated conduit by means of a solderless connector approved for the purpose . C . The neutral ground conductor shall follow the shortest path between the service and the neutral ground source . All contact surfaces shall be thoroughly cleaned prior to final connections . The

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.34 CONSTRUCTION STANDARDS Section 3

connection to the neutral ground source shall be visible for inspection at all times . Where the cold water meter is provided, the meter shall be jumpered by bonding wraps of equal cross- sectional areas to the main ground conductor . D . Provide a 3/4” x 10’-0” driven ground rod(s) bonded to water piping system by No . 6 (minimum) bare copper conductors, and to the main distribution center in accordance with Paragraph 250- 84 or the N .E C. . E . An equipment grounding conductor with green colored identification, sized in accordance with Table 250-95 of the N.E.C. shall be installed in all flexible metallic conduit or any non- metallic raceway for the entire length of the system . The equipment ground conductor shall be connected to a separate equipment ground in the circuit originating panel board, switchboard, etc . Connect ground wire to equipment ground terminal of all devices . Provide ground bonding jumper from grounding terminal of three (3) wire receptacles to outlet box where ground wire is not pulled .

12.6 RACEWAYS AND WIRING All wiring shall be installed in conduit . Use corrosion resistant rigid steel with PVC coating or heavy wall PVC in earth or in slabs where slabs are in contact with earth . Provide rigid steel cells coated with PVC where PVC raceways are used . For conduit runs 2” in diameter and larger in earth or in slabs in contact with earth, P V. C. . raceways with 4” concrete envelopes may be used . Provide rigid PVC coated steel elbows and conduits for stub-ups above grade .

Direct burial runs may be installed where located outside the building, under asphalt paving, and under grass or bare earth where noted . Enclose conductors in rigid galvanized PVC, coated, or PVC conduit where runs enter outlet boxes, concrete pole bases, under concrete walks, or embedded in concrete slabs or masonry walls . A . Conduit shall be of the size required by, and installed according to the N .E C. . Bends shall be made with approved hickey or conduit bending machine . Provide supports in accordance with N E. C. . requirements . B. Maximum size conduit allowed in floor slabs above grade shall be 1” unless written permission is obtained from the Structural Engineer . All secondary conductors to be buried a minimum of 30” below finished grade . Provide 2” sand fill above and below conductors and install treated or redwood board . C . Exposed conduit shall not be installed in finished areas . Exposed conduit may be installed at surface mounted equipment and at other locations approved by the Owner . All exposed conduit shall be run parallel to or at right angles to building lines . D . In locations where mechanical damage may be incurred, or on roofs, corrosion resistant rigid steel or intermediate metal conduit shall be used except heavy wall aluminum may be used in dry locations where exposed . No aluminum conduit shall be used in walls or concrete . Electric metallic tubing or intermediate metal conduit may be used in all other applications . E . Use approved type couplings and connectors in all conduit runs, and make all joints tight . Provide insulated bushings for all terminations in pipe sizes 11/4” and larger . Provide a premium quality metal casting type of compression gland coupling for all other concealed or exposed conduits . Set-secure type couplings will be permitted for exposed EMT conduits only . Provide expansion fittings and bonding conductors for all runs which cross building expansion joints . Provide waterproof fittings for all runs in we locations, such as exposed to weather, buried in slabs, etc . Provide seal-off fittings where conduits enter or leave a hazardous area, or areas of widely different temperature and/or humidity . Fittings shall be as manufactured by one of the following: 1 . O .Z . 4 . Appleton 2 . Tomic 5 . Steel City 3 . Raco 6 . I & B F . No wire shall be installed until work which might cause damage to the conductors has been completed . Prior to pulling of the conductors, conduits shall be swabbed clean of all foreign matter, or replaced where such accumulation cannot be removed by approved methods .

12.7 IDENTIFICATION OF EQUIPMENT Legible and complete wiring and circuitry diagrams, lamp sizes and wattage and any special operating or replacement instructions are to be provided on waterproof paper and firmly affixed to the interior of signage access panels . Identify all applicable circuits in branch circuit panel boards with a typewritten directory mounted behind clear plastic and fastened to inside of panel door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.35 CONSTRUCTION STANDARDS Section 3

12.8 INSPECTIONS, TESTS AND GUARANTEES All work shall be subject to inspection by the Owner, the Owner’s Representative and the Graphic Designer at all times and in the event of questionable work, their decision will be final .

After the electrical installation is completed and at such times as the Owner or the D C. D. O. . may direct, the Signage Contractor shall conduct an operating test for approval . The installation shall be demonstrated to be in accordance with the requirements of this specification . Any defects revealed shall be corrected promptly and the test reconducted, at no additional cost to the Owner .

All electrical work and all items of equipment and materials shall be guaranteed for a period of one (1) year from the date of the final inspection and acceptance of the work . The Signage Contractor shall be notified in writing of any defective items and shall repair or replace such items promptly without cost to the Owner .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.36 CONSTRUCTION STANDARDS Section 3

INSTALLATION REQUIREMENTS 13–57

Table 8.6.5.1.2 Positioning of Sprinklers to Avoid Obstructions to Discharge (SSU/SSP) Ceiling

Maximum Allowable Distance of B Distance from Deflector Above Sprinklers to Bottom of Side of Obstruction (A) Obstruction (in.) (B) Obstruction Less than 1 ft 0 DA 1 ft to less than 1 ft 6 in. 21⁄2 1 ft 6 in. to less than 2 ft 31⁄2 2 ft to less than 2 ft 6 in. 51⁄2 2 ft 6 in. to less than 3 ft 71⁄2 3 ft to less than 3 ft 6 in. 91⁄2 3 ft 6 in. to less than 4 ft 12 A ≥ (D − 8 in.) + B 4 ft to less than 4 ft 6 in. 14 Wall [A ≥ (D – 0.2 m) + B ] 4 ft 6 in. to less than 5 ft 161⁄2 where: D ≤ 30 in. (0.8 m) 5 ft to less than 5 ft 6 in. 18 5 ft 6 in. to less than 6 ft 20 6 ft to less than 6 ft 6 in. 24 Elevation View 6 ft 6 in. to less than 7 ft 30 7 ft to less than 7 ft 6 in. 35 FIGURE 8.6.5.1.2(b) Obstructions Against Walls (SSU/SSP).

For SI units, 1 in. = 25.4 mm; 1 ft = 0.3048 m. Note: For (A) and (B), refer to Figure 8.6.5.1.2(a).

than the maximum dimension of the web members away from the web members. Ceiling 8.6.5.2.1.8 The requirements of 8.6.5.2.1.3 shall not apply to sprinkler system piping less than 3 in. (80 mm) in diameter. • 8.6.5.2.1.9 The requirements of 8.6.5.2.1.3 shall not apply to sprinklers positioned with respect to obstructions in accor- dance with 8.6.5.1.2. B 8.6.5.2.2 Suspended or Floor-Mounted Vertical Obstructions. The distance from sprinklers to privacy curtains, freestanding Obstruction partitions, room dividers, and similar obstructions in light haz- ard occupancies shall be in accordance with Table 8.6.5.2.2 and Figure 8.6.5.2.2.

A 8.6.5.2.2.1* In light hazard occupancies, privacy curtains that are supported by fabric mesh on ceiling track and have open- ings in the mesh equal to 70 percent or greater and extend a Elevation View minimum of 22 in. (559 mm) from ceiling shall not be consid- ered obstructions as shown in 8.6.5.2.2. FIGURE 8.6.5.1.2(a) Positioning of Sprinklers to Avoid Ob- structions to Discharge (SSU/SSP). 8.6.5.3* Obstructions That Prevent Sprinkler Discharge from Reaching the Hazard. 8.6.5.3.1 Continuous or noncontinuous obstructions that in- centerline of the obstruction to the sprinklers does not exceed terrupt the water discharge in a horizontal plane more than one-half the allowable distance between sprinklers. 18 in. (457 mm) below the sprinkler deflector in a manner to 8.6.5.2.1.6 Sprinklers shall be permitted to be located one- limit the distribution from reaching the protected hazard half the distance between the obstructions where the obstruc- shall comply with 8.6.5.3. tion consists of open trusses 20 in. (0.51 m) or greater apart 8.6.5.3.2 The requirements of 8.6.5.3 shall also apply to ob- [24 in. (0.61 m) on center], provided that all truss members structions 18 in. (457 mm) or less below the sprinkler for light are not greater than 4 in. (102 mm) (nominal) in width. and ordinary hazard occupancies. 8.6.5.2.1.7 Sprinklers shall be permitted to be installed on 8.6.5.3.3 Sprinklers shall be installed under fixed obstruc- the centerline of a truss or bar joist or directly above a beam, tions over 4 ft (1.2 m) wide, such as ducts, decks, open grate provided that the truss chord or beam dimension is not more flooring, cutting tables, and overhead doors. than 8 in. (203 mm) and the sprinkler deflector is located at least 6 in. (152 mm) above the structural member and where 8.6.5.3.4 Sprinklers shall not be required below obstructions the sprinkler is positioned at a distance three times greater that are not fixed in place, such as conference tables.

--`,,,,,,`,,,``,,`,```,,`,,````-`-`,,`,,`,`,,`--- 2007 Edition

Copyright National Fire Protection Association Provided by IHS under license with NFPA Licensee=Smith Seckman Reid Inc/5968207001, User=Crow, Carl No reproduction or networking permitted without license from IHS Not for Resale, 07/24/2007 14:04:12 MDT

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 3.37 GRAPHIC STANDARDS Section 4

PAINT COLORS Color Standards This color family has been selected P-1 Black Matthews Paint MP30132 Satin Finish for the strong contrast between typographic elements and sign P-2 White Matthews Paint MP11477 Satin Finish background .

P-3 Red Matthews Paint MP15351 Satin Finish Silk screen ink colors are to match paint colors noted . P-4 Yellow Matthews Paint MP00053 Satin Finish Paint finishes to be semi-gloss for P-5 Orange Matthews Paint MP00176 Satin Finish all exterior signs and satin for all interior signs . P-6 Purple Matthews Paint MP00878 Satin Finish P-7 Blue Matthews Paint MP02110 Satin Finish P-8 Green Matthews Paint MP14334 Satin Finish P-9 Pink Matthews Paint MP08744 Satin Finish P-10 Brown Matthews Paint MP00158 Satin Finish P-11 Silver Matthews Paint 41342SP Satin Finish P-12 Exterior Blue Matthews Paint MP02306 Semi-Gloss Finish P-13 Exterior White Matthews Paint MP11477 Semi-Gloss Finish P-14 Exterior Gray Matthews Paint MP15661 Semi-Gloss Finish P-15 Exterior Metallic Silver-Gray Matthews Paint MP18205 Semi-Gloss Finish P-16 HCHD Blue Matthews Paint to match PMS 289 Satin Finish P-17 HCHD Tan Matthews Paint to match PMS 465 Satin Finish P-18 Duranotic Bronze Matthews Paint MP20356 Semi-Gloss Finish

VINYL COLORS

V-1 Black 3M Scotchcal 7725-22 Matte Black Opaque V-2 White 3M Scotchcal 7725-20 Matte White Opaque V-3 Red 3M Scotchcal 7725-63 Geranium Opaque V-4 Silver 3M Scotchcal 7725-120 Satin Aluminum Opaque V-5 Blue 3M Scotchcal 7725-37 Sapphire Blue Opaque V-6 Green 3M Scotchcal 7725-186 Bright Green Opaque V-7 Tan 3M Scotchcal 7725-39 Tan Opaque V-8 Translucent Blue 3M Scotchcal 3630-157 Sultan Blue Translucent V-9 Translucent Tan Oracal 8500 series #081 Light Brown Translucent

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 4.1 GRAPHIC STANDARDS Section 4

PROJECT FONTS Font Standards

This system contains three font, selected for legibility and support ABCDEFGHIJKLMNOPQRSTUVWXYZ of the Harris County Hospital District brand . Therefore, it is abcdefghijklmnopqrstuvwxyz important to maintain these type styles throughout the signage 1234567890 system . No substitutions for these fonts are Helvetica LT Std Bold allowed.

All fonts can be purchased from www.Adobe.com. It is the responsibility of the Fabricator to ABCDEFGHIJKLMNOPQRSTUVWXYZ purchase these fonts for use with this Master Plan . abcdefghijklmnopqrstuvwxyz For maximum readability, upper and lower case letters are used whenever possible in the system . 1234567890 Information presented in this format is read and comprehended Helvetica LT Std Roman considerably faster than information presented in all capital letters .

Specific layouts and type styles are shown for the individual sign types ABCDEFGHIJKLMNOPQRSTUVWXYZ in sections following . abcdefghijklmnopqrstuvwxyz 1234567890 Helvetica LT Std Oblique

ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz 1234567890 ITC Officina Sans Std Bold

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 4.2 GRAPHIC STANDARDS Section 4

PROJECT LETTERSPACING Typography Standards

Type viewed from a distance is Admissions Office more legible if the letterspacing Spacing too tight is more open . The samples at left show correct and incorrect letterspacing and wordspacing for maximum readability . Typical Admissions Office layouts for each individual sign type Correct spacing are shown in sections following .

Examples are shown at 30 pt . Fabricator is responsible for visually Admissions Office matching this spacing, as each Spacing too open software program uses a different numerical system .

Spacing must stay consistent . Compressing the type to fit additional text on a line is not Admissions Office allowed . Spacing too tight Admissions Office Correct spacing Admissions Office Spacing too open

Admissions Office Spacing too tight Admissions Office Correct spacing Admissions Office Spacing too open

Admissions Office Spacing too tight Admissions Office Correct spacing Admissions Office Spacing too open

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 4.3 GRAPHIC STANDARDS Section 4

PROJECT ARTWORK Symbol Standards

These symbols should be used throughout the system .

Electronic artwork provided by Harris County Hospital District, per the provided disk found in the back of this manual .

Project Arrow Project Arrow Destination Oval Accessible Restroom Symbol Restroom Symbol

Emergency Cafeteria Symbol Elevator Symbol “In Case Of Fire” Biohazard Symbol Symbol Symbol

Radiation Symbol “Do Not Enter” “No Smoking” “No Handgun” “High Voltage” Symbol Symbol Symbol Symbol

“No Pacemakers” “No Credit Cards” “No Large Metal “No Small Metal Warning Symbol Symbol Symbol Objects” Symbol Objects” Symbol

Magnet Symbol Parking Symbol

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 4.4 GRAPHIC STANDARDS Section 4

PROJECT REFERENCES Drawing Notation 4/Page 4.2 Standards Elevation These symbols will be used 1 Scale throughout the Master Plan document . Drawing No. Section View Indicates drawing number, drawing title Left number indicates detail number. Right and scale. number indicates page where detail is located. Single number, detail is located on 1 same page. 4/Page 4.2 Material Reference Indicates material specifications.

Ground Lines Detail Reference Indicates an area that has been enlarged or Visible Object Lines detailed. Left number indicates detail number, Indicates separation of objects and edges right number indicates page where detail is of objects. located. Single number, detail is located on same page.

Hidden Object Lines Indicates edges of objects behind visible 4/Page 4.2 objects.

Elevation Reference Color Lines Indicates that point of view. Indicates separation of colors on object.

Match Line A 2 See EG.00 for Continuation

Match Line Revision Bubble & Reference Indicates where multiple drawings align. Indicates a revised portion Top text indicates matching edge, bottom of a drawing. number indicates page where matching drawing is located.

Broken Segment

1 1/2"

Dimension Lines

Scale Figure Indicates a scale reference. Center Line Figure would be 6'-0" actual size.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 4.5 EXTERIOR SIGNS Section 5

EL FRANCO LEE HEALTH CENTER 8901 Boone Road

SOUTHWEST ELIGIBILITY CENTER 8901B Boone Road

EXT.01.2C Monument Sign Vertical, Metallic Silver-Grey 1 Scale : 3/8” = 1’ - 0”

EXT.01.2C Monument Sign Vertical, Metallic Silver-Grey An internally-illuminated sign with push-thru logo/logotype/adress used to identify a facility . Use this sign only when a white signs is required by Landlord Signage Criteria; whenever possible, use sign type EXT 01. .2A as the preferred option .

Sign is shown at Designer’s recommended size, but may be resized to fit local conditions .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 5.1 EXTERIOR SIGNS Section 5

EXT.01.2C Monument Sign Vertical, Metallic Silver-Grey

1 . Fabricated aluminum sign can to be 1/8” thick faces and returns, seemlessly fabricated around internal frame structure . All exposed surfaces painted to match P-15 Exterior Metallic Silver-Grey or approved alternative . 9'-6" 2'-0" 2 . Sign base may be fabricated 3" 9'-0" 3" 3" 1'-6" 3" aluminum painted to match sign face or an alternate material such as brick or concrete to match the facility architecture . Base height will vary by location . Entire sign assembly to be mounted onto a poured into place, cast concrete foundation . Size and depth of foundation to be engineered by a structural engineer licensed in the State of Texas, to meet local wind load requirements and detailedvon signed and stamped shop drawings .

3 . District-approved logo and facility logotype to be computer routered out of the sign face . Logo and logotype to be 3/8” thick milky white acrylic with FACILITY LOGO a matte finish on the face and 18'-0" AND ADRESS 18'-0" returns to be push-thru sign face and be offset 1/16” from original typeface . Logo and copy to be solvent glued to an additional 1/4” thick milky white acrylic diffuser panel for mounting . Laminated pieces to be pushed-thru routed face of sign can with the back diffuser 3 panel mechanically fastened with thru blind studs on interior side of sign can . Face of push-thru 1 1 logo to have 1/32” thick applied aluminum painted to match P-16 (HCHD Blue) and P-17 (HCHD Tan), as required .

4 . Awarded signage contractor to verify square footage and height 2 2 allowances with local ordinances varies varies prior to fabrication .

5 . Fabricator to provide Front Elevation Side Elevation dimensioned layouts for 2 Scale : 1/4” = 1’ - 0” 3 Scale : 1/4” = 1’ - 0” approval . 6 . Vector-based artwork for each sign will be provided by HCHD .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 5.2 EXTERIOR SIGNS Section 5

EXT.03.2 Wall-Mounted Letters, White 1 Scale : 1/8” = 1’ - 0”

EXT.03.2 Wall-Mounted Letters, White Internally-illuminated wall-mounted letters used to identify a facility . Use this sign only when a white signs is required by architecture or Landlord Signage Criteria; whenever possible, use sign type EXT 03. 1. as the preferred option .

Sign is shown at Designer’s recommended size, but may be resized proportionally to fit local conditions such as viewing distance, available space and signage ordinances .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 5.3 EXTERIOR SIGNS Section 5

23’- 6" 4’- 0" 18’- 11"

" 1 2 4’- 0

3 4 Detail Elevation 2 Scale : 1/4” = 1’ - 0”

6" EXT.03.2 Wall-Mounted Letters, White

1 . Fabricated aluminum face-lit letterforms with white acrylic . Returns and trim cap painted to match P-12 Exterior Blue or " 1 3 approved alternative . 4’- 0 Letterforms to be internally illuminated with white LED lighting . Electrical service and wall penetrations to be verified by project . Provide timed control circuit for illumination . Side Elevation Letters must be a minimum 3 Scale : 1/4” = 1’ - 0” of 6” to allow for illumination hardware.

2 . Translucent white face .

3 . Fabricated aluminum face-lit sign can . Returns and trim cap painted to match P-12 Exterior Blue .

4 . Translucent white face with applied translucent vinyl logo to match V-8 Translucent Blue and V-9 Translucent Tan .

" 5 . Verify square footage allowances with local ordinances prior to " 37’- 4 fabrication . 31’- 8 6 . Fabricator to provide dimensioned layouts for approval .

7 . Entire sign assembly to be mechancially fastened to existing building façade, with fasteners sizes and type to be engineered by a structural engineer licensed Location Elevation at West Building Elevation in the State of Texas, to meet 4 Scale : 1/16” = 1’ - 0” local wind load requirements and detailed on signed and stamped shop drawings .

8 . Vector-based artwork for each sign will be provided by HCHD .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 5.4 EXTERIOR SIGNS Section 5

Community Eligibility Center

Clinic

EXT.04 Vehicular Directional 1 Scale : 1/2” = 1’ - 0”

EXT.04 Vehicular Directional A non-illuminated ground-mounted sign used to direct low-speed vehicular traffic around facilities .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 5.5 EXTERIOR SIGNS Section 5

EXT.04 Vehicular Directional

4'-6" 1 . 3” square aluminum posts painted to match P-13 Gray . Set 3" 4'-0" 3" posts in 3000 PSI reinforced concrete foundation at a minimum depth of 2’-0” to withstand 30 PSF wind loading .

8" 1 2 . Fabricated aluminum sign can painted to match P-13 Exterior 3 White . Return color on all faces . 3 . Header field painted to match 2 P-12 Exterior Blue or approved alternative .

3'-4" 4 . Applied vinyl logo and text to match V-2 White, V-5 Blue and

2'-8" V-7 Tan or approved alternatives .

5 . Applied vinyl text to match V-1

5'-0" Black . Font: Helvetica LT Std Bold .

6 . Vector-based artwork for each sign will be provided by HCHD .

Front Elevation 2 Scale : 3/4” = 1’ - 0”

4'-6"

3" 4'-0" 3"

3" 1 2 Plan View 3 Scale : 3/4” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 5.6 EXTERIOR SIGNS Section 5

EXT.04 Vehicular Directional

1 3/4" 2'-1 1/2" 1 . 3” square aluminum posts painted to match P-13 Gray . Set posts in 3000 PSI reinforced EQ concrete foundation at a

5" 4 minimum depth of 2’-0” to withstand 30 PSF wind loading . EQ 2 . Fabricated aluminum sign can painted to match P-13 Exterior Header Panel White . Return color on all faces . 4 Scale : 3/4” = 1’ - 0” 3 . Header field painted to match P-12 Exterior Blue or approved alternative .

1 1/2" 4 . Applied vinyl logo and text to 1 3/4" 4" 3'-3" max message length 1 3/4" match V-2 White, V-5 Blue and V-7 Tan or approved alternatives .

5 . Applied vinyl text to match V-1 5 1/2" 3" 4" Directional Text 5 Black . Font: Helvetica LT Std Bold . 6" Directional Text 6 . Vector-based artwork for each sign will be provided by HCHD . 6" Directional Text 6" 3" 4" Directional Text 6" Directional Text

Message Panel 5 Scale : 3/4” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 5.7 EXTERIOR SIGNS Section 5

WESTLANDS CLINIC

EXT.13 Glass Canopy Identity 1 Scale : 3/32” = 1’ - 0”

EXT.013 Glass Canopy Identity A non-illuminated glass façade-mounted letters used to identify a facility . Due to mounting conditions, logo assembly and logotype to be mounted on continuous race-way to allow for unified installed .

Sign is shown at Designer’s recommended size, but may be resized proportionally to fit local conditions such as viewing distance, available space and signage ordinances .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 5.8 EXTERIOR SIGNS Section 5

EXT.013 Glass Canopy Identity

1 . Fabricated aluminum letterforms 15’- 2 1/2" with white acrylic faces . Returns 3’- 4 1/2" 11’- 7" and trim cap painted to match P-12 Exterior Blue or approved alternative .

2 . White acrylic face . " 1 2 3 . Fabricated aluminum sign can . WESTLANDS Returns and trim cap painted to 3’- 4 1/2 5 match P-12 Exterior Blue . LINIC 4 . White acrylic face with applied C translucent vinyl logo to match 3 4 V-8 Translucent Blue and V-9 Detail Elevation Translucent Tan . 2 Scale : 1/4” = 1’ - 0” 5 . Fabricated auminum raceway used for mounting to existing window mullions . Raceways painted to match P-15 Exterior Metallic Silver-Grey .

6 . Verify square footage allowances 3" 3" with local ordinances prior to fabrication .

" 7 . Fabricator to provide "

1’- 8 dimensioned layouts for 1 2 approval . " 3’- 4 1/2 8 . Entire sign assembly to be

1’- 8 5 mechancially fastened to existing building façade, with fasteners sizes and type to be engineered by a structural engineer licensed Side Elevation in the State of Texas, to meet 3 Scale : 1/4” = 1’ - 0” local wind load requirements and detailed on signed and stamped shop drawings .

9 . Vector-based artwork for each sign will be provided by HCHD .

WESTLANDS CLINIC

Location Elevation at Entrance Canopy 4 Scale : 3/32” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 5.9 INTERIOR SIGNS Section 6

3/Page 6.1 2/Page 6.1

LYNDON B. JOHNSON Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 GENERAL HOSPITAL Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 Harris County Hospital District Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10

Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 Eligibility Office 1 1B 06

Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10

Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 Eligibility Office 1 1B 06

Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10

Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 Eligibility Office 1 1B 06

Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10

Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 Eligibility Office 1 1B 06 Eligibility Office 1 1B 06

Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Emergency Registration 1 1D 10 Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Map Artwork Physical Medicine and Rehabilitation 2 2A 10 Physical Medicine and Rehabilitation 2 2A 10 Not In Designer’s Scope

INT.01.1 Directory, Large 1 Scale : 3/4” = 1’ - 0”

LYNDON B. JOHNSON GENERAL HOSPITAL Harris County Hospital District

Detail, Map Module 2 Scale : 3” = 1’ - 0”

Name Floor Room Nombre Piso Sitio Tên Lâu Phòng

Eligibility Office 1 1B 06

Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10

Detail, Message Module 3 Scale : 3” = 1’ - 0”

INT.01.1 Directory, Large Changeable wall-mounted, non-illuminated directory that presents public destinations, floor numbers and destination numbers for the entire facility. Locate in each public entrance lobby of a facility and first floor elevator lobby. For smaller facilities or upper floors, use sign type INT.01.2.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.1 INTERIOR SIGNS Section 6

INT.01.1 Directory, Large 7'-1 1/4" 1 . Message Module . See Page 6 .3 for details . 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1'-2 1/2" 1'-2 1/2" 1'-6 1/4" 1'-2 1/2" 1'-2 1/2" 2 . Stopper Module . See Page 6 .4 for details . 3/4" 3/4" 6 / Page 6.2 3 . Map Module . See Page 6 .5 for details . 1 4 . Sign pan to be fabricated of 1/8” aluminum with aluminum angle 2 sub-frame . Painted on all visible sides to match P-11 Silver . Fasten to wall angles with countersunk 3'-0" tamper-proof screws .

3 Front Elevation 4 Scale : 1/2” = 1’ - 0”

2 1/4"

3/4" 1 1/2"

1/8" 1 1/4" 1/8"

4

2 4 3'-0" 1/8"

Side Elevation Side Section, Pan 5 Scale : 3” = 1’ - 0” 6 Scale : Full Size

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.2 INTERIOR SIGNS Section 6

INT.01.1 Directory, Large

1'-2 1/2" 4 . Sign pan to be fabricated of 1/8” aluminum with aluminum angle sub-frame . Painted on all visible 5 sides to match P-11 Silver . Fasten to wall angles with countersunk 2"

2 1/8" 6 tamper-proof screws .

5 . Aluminum “C” channel as 1" 1 1/8" 7 provided by The JRS Company (Part No . 36) in satin silver finish . Permanently attached to Middle 1 1/8" 8 Panel .

The JRS Company

3'-0" 544 North Rimsdale Avenue Box 2035 Covina, CA 91722 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com.

6 . Header Insert to be 052”. Rowmark Lasermark engraving material to match 922-344 Smooth Silver / Black .

Front Elevation, Message Module Rowmark, LLC 2040 Industrial Drive 7 Scale : 3” = 1’ - 0” Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

7 . Aluminum “C” channel as provided by The JRS Company (Part No . 28) in satin silver finish . Permanently attached to Middle Panel . 30 channels per column . 5 8 . Listing Strip Insert to be 052”. 6 Rowmark Lasermark engraving material to match 922-402 Black 2"

2 1/8" / White . Adhere into “C” channel with film tape .

7 1" 1 1/8" 8 3'-0"

4

Side Elevation, Message Module 8 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.3 INTERIOR SIGNS Section 6

INT.01.1 2 1/4" Directory, Large

3/4" 1 1/2" 4 . Sign pan to be fabricated of 1/8” 10/Page 6.4 aluminum with aluminum angle sub-frame . Painted on all visible sides to match P-11 Silver . Fasten

1/8" 9 to wall angles with countersunk tamper-proof screws .

9 . Stopper Cap to be 1/8” aluminum seamlessly welded to aluminum Stopper Tube . Painted on all 10 visible sides to match P-11 Silver . Stopper Module mechanically fastened flush to sign pan with countersunk tamper-proof screws . 3'-0" 10 . Stopper Tube to be standard 1/8” aluminum 3/4” x 1 1/2” square tube . Seamlessly welded to aluminum Stopper Cap . Painted on all visible sides to match P-11 Silver . Stopper Module mechanically fastened flush to sign pan with countersunk tamper-proof screws . 1/8"

Side Elevation, Stopper Module 9 Scale : 3” = 1’ - 0”

3/4" 1 1/2"

9

10

4

Detail, Stopper Module 10 Scale : Full Size

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.4 INTERIOR SIGNS Section 6

INT.01.1 Directory, Large

1'-6 1/4" 4 . Sign pan to be fabricated of 1/8” aluminum with aluminum angle 3/4" 1'-4 3/4" 3/4" sub-frame . Painted on all visible sides to match P-11 Silver . Fasten 1'-6" to wall angles with countersunk tamper-proof screws . 11 11 . Stopper Cap to be 1/8” aluminum 12/Page 6.5

1/8" panel . Painted on all visible sides to match P-11 Silver . Mechanically fastened flush to sign pan with countersunk tamper-proof screws .

12 12 . Map Insert Track to be standard 1/8” aluminum 3/4” square channel . Painted on all visible 12 sides to match P-11 Silver . 3'-0" Permanently adhere flush to sign 13 pan . 13 . Map Insert Window to be 1/8” clear Lexan .

14 . Map Insert to be full-color digital print mounted to rigid backer with spacer to sit flush in Map

1/8" Insert Track . Digital artwork provided by Owner . 11 Front Elevation, Map Module 11 Scale : 1 1/2” = 1’ - 0”

11

1 1/2" 4 3/8" 3/4" 12

1/8" 14 13 Top Section, Map Module 12 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.5 INTERIOR SIGNS Section 6

INT.01.1 Directory, Large

1/2" 9 1/2" 2 3/8" 15 . Laser engraved text . Font: Helvetica LT Std Bold .

3/8" 15 16 . Laser engraved text . Font: 5/8" Name Floor Room Helvetica LT Std Roman .

9/16" Nombre Piso Sitio 16 Tên Sàn Buông 17 . Laser engraved text . Font: Helvetica LT Std Oblique . 9/16" 17 Message Module, Header Strip 18 . Laser engraved oval to leave text . 13 Scale : 3” = 1’ - 0” Font: ITC Officina Sans Std Bold .

1'-2 1/2" 1/2" 1/4" 1/2" 9" max message length 1/2" 1 7/8" 3/4" 5/8" 1/2" 15/Page 6.6 EQ

1" Single-Line Message Text # 1H

3/8" 12

EQ 1" 16 EQ

1" Multiple-Line Message Text # 1H

3/8" 12 EQ Multiple-Line Message Text # 1H 12

Message Module, Listing Strip 16 14 Scale : 3” = 1’ - 0”

3/4" 1/4" 5/8" 1/2" 1/4" 1/2" 3/8" 1H 12 5/16" 1/4"

15 18 Message Module, Listing Strip Detail 15 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.6 INTERIOR SIGNS Section 6

INT.01.1 Directory, Large

19 . Logo field of Map Insert to match 1'-6" P-11 Silver with Facility Logo 1 1/4" 1'-3 1/2" max message length 1 1/4" according to HCHD graphic standards . Facility logo to be first-surface applied as (19a)

3/4" HCHD Circle Logo as a high resolution, digital print to match P-2 (white) P-16 (HCHD Blue) and P-17 (HCHD Tan) and 3" Facility Logo 4 1/2" 19 (19b) logo text and rule to be computer-cut vinyl to match V-5 (blue) . 3/4" 3/4" 20 .Map and Information field of Map 20 Insert to match P-1 Black .

Wayfinding Map and Information (Map Artwork Not In Designer’s Scope) 2'-7 1/2" 2'-7 2'-6" max message height 3/4"

Map Module, Insert 16 Scale : 1 1/2” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.7 INTERIOR SIGNS Section 6

2/Page 6.8 3/Page 6.8

LYNDON B. JOHNSON GENERAL HOSPITAL Eligibility Office 1 1B 06 Harris County Hospital District Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10

Eligibility Office 1 1B 06

Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10

Eligibility Office 1 1B 06

Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10

Eligibility Office 1 1B 06

Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10

Eligibility Office 1 1B 06

Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10

INT.01.2 Directory, Small 1 Scale : 3/4” = 1’ - 0”

LYNDON B. JOHNSON GENERAL HOSPITAL Harris County Hospital District

Detail, Map Module 2 Scale : 3” = 1’ - 0”

Eligibility Office 1 1B 06

Emergency Registration 1 1D 10

Physical Medicine and Rehabilitation 2 2A 10

Detail, Message Module 3 Scale : 3” = 1’ - 0”

INT.01.2 Directory, Small Changeable wall-mounted non-illuminated directory that presents public destinations, floor numbers and destination numbers for smaller facilities or individual upper floors. Locate in each public entrance lobby of a smaller facility or floor elevator lobbies. For larger facilities or ground floors, use sign type INT.01.1.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.8 INTERIOR SIGNS Section 6

INT.01.2 Directory, Small 2'-11 3/4" 1 . Message Module . See Page 6 10. 1 1/2" 1 1/2" for details . 1'-6 1/4" 1'-2 1/2" 2 . Stopper Module . See Page 6 11. for details . 3/4" 3/4" 6/Page 6.9 3 . Map Module . See Page 6 12. for details . 1 4 . Sign pan to be fabricated of 1/8” aluminum with aluminum angle 2 sub-frame . Painted on all visible sides to match P-11 Silver . Fasten to wall angles with countersunk 3'-0" tamper-proof screws .

3 Front Elevation 4 Scale : 1/2” = 1’ - 0”

2 1/4"

3/4" 1 1/2"

1/8" 1 1/4" 1/8"

4

2 4 3'-0" 1/8"

Side Elevation Side Section, Pan 5 Scale : 3” = 1’ - 0” 6 Scale : Full Size

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.9 INTERIOR SIGNS Section 6

INT.01.2 Directory, Small

1'-2 1/2" 4 . Sign pan to be fabricated of 1/8” aluminum with aluminum angle sub-frame . Painted on all visible 5 sides to match P-11 Silver . Fasten to wall angles with countersunk 2"

2 1/8" 6 tamper-proof screws .

5 . Aluminum “C” channel as 1" 1 1/8" 7 provided by The JRS Company (Part No . 36) in satin silver finish . Permanently attached to Middle 1 1/8" 8 Panel .

The JRS Company

3'-0" 544 North Rimsdale Avenue Box 2035 Covina, CA 91722 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com.

6 . Header Insert to be 052”. Rowmark Lasermark engraving material to match 922-344 Smooth Silver / Black .

Front Elevation, Message Module Rowmark, LLC 2040 Industrial Drive 7 Scale : 3” = 1’ - 0” Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

7 . Aluminum “C” channel as provided by The JRS Company (Part No . 28) in satin silver finish . Permanently attached to Middle Panel . 30 channels per column . 5 8 . Listing Strip Insert to be 052”. 6 Rowmark Lasermark engraving material to match 922-402 Black 2"

2 1/8" / White . Adhere into “C” channel with film tape .

7 1" 1 1/8" 8 3'-0"

4

Side Elevation, Message Module 8 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.10 INTERIOR SIGNS Section 6

INT.01.2 2 1/4" Directory, Small

3/4" 1 1/2" 4 . Sign pan to be fabricated of 1/8” 10/Page 6.11 aluminum with aluminum angle sub-frame . Painted on all visible sides to match P-11 Silver . Fasten

1/8" 9 to wall angles with countersunk tamper-proof screws .

9 . Stopper Cap to be 1/8” aluminum seamlessly welded to aluminum Stopper Tube . Painted on all 10 visible sides to match P-11 Silver . Stopper Module mechanically fastened flush to sign pan with countersunk tamper-proof screws . 3'-0" 10 . Stopper Tube to be standard 1/8” aluminum 3/4” x 1 1/2” square tube . Seamlessly welded to aluminum Stopper Cap . Painted on all visible sides to match P-11 Silver . Stopper Module mechanically fastened flush to sign pan with countersunk tamper-proof screws . 1/8"

Side Elevation, Stopper Module 9 Scale : 3” = 1’ - 0”

3/4" 1 1/2"

9

10

4

Detail, Stopper Module 10 Scale : Full Size

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.11 INTERIOR SIGNS Section 6

INT.01.2 Directory, Small

1'-6 1/4" 4 . Sign pan to be fabricated of 1/8” aluminum with aluminum angle 3/4" 1'-4 3/4" 3/4" sub-frame . Painted on all visible sides to match P-11 Silver . Fasten to wall angles with countersunk 1'-6" tamper-proof screws .

11 11 . Stopper Cap to be 1/8” aluminum

12/Page 6.12 panel . Painted on all visible sides 1/8" to match P-11 Silver . Mechanically fastened flush to sign pan with countersunk tamper-proof screws .

12 . Map Insert Track to be standard 12 1/8” aluminum 3/4” square channel . Painted on all visible 12 sides to match P-11 Silver .

3'-0" Permanently adhere flush to sign pan . 13 13 . Map Insert Window to be 1/8” clear Lexan .

14 . Map Insert to be full-color digital print mounted to rigid backer with spacer to sit flush in Map Insert Track . Digital artwork 1/8" provided by Owner . 11 Front Elevation, Map Module 11 Scale : 1 1/2” = 1’ - 0”

11

1 1/2" 4 3/8" 3/4" 12

1/8" 14 13 Top Section, Map Module 12 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.12 INTERIOR SIGNS Section 6

INT.01.2 Directory, Small

1/2" 9 1/2" 2 3/8" 15 . Laser engraved text . Font: Helvetica LT Std Bold .

3/8" 15 16 . Laser engraved text . Font:

5/8" Floor Room Name Helvetica LT Std Roman .

9/16" Nombre Piso Sitio 16 Tên Sàn Buông 17 . Laser engraved text . Font: Helvetica LT Std Oblique . 9/16" 17 Message Module, Header Strip 18 . Laser engraved oval to leave text . 13 Scale : 3” = 1’ - 0” Font: ITC Officina Sans Std Bold .

1'-2 1/2" 1/2" 1/4" 1/2" 9" max message length 1/2" 1 7/8" 3/4" 5/8" 1/2" 15/Page 6.13 EQ

1" Single-Line Message Text # 1H

3/8" 12

EQ 1" 16 EQ

1" Multiple-Line Message Text # 1H

3/8" 12 EQ Multiple-Line Message Text # 1H 12

Message Module, Listing Strip 16 14 Scale : 3” = 1’ - 0”

3/4" 1/4" 5/8" 1/2" 1/4" 1/2" 3/8" 1H 12 5/16" 1/4"

15 18 Message Module, Listing Strip Detail 15 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.13 INTERIOR SIGNS Section 6

INT.01.2 Directory, Small

19 . Logo field of Map Insert to match 1'-6" P-11 Silver with Facility Logo according to HCHD graphic 1 1/4" 1'-3 1/2" max message length 1 1/4" standards . Facility logo to be first-surface applied as (19a) HCHD Circle Logo as a high

3/4" resolution, digital print to match P-2 (white) P-16 (HCHD Blue) and P-17 (HCHD Tan) and

3" Facility Logo (19b) logo text and rule to be 4 1/2" 19 computer-cut vinyl to match V-5 (blue) . 3/4" 3/4" 20 .Map and Information field of Map 20 Insert to match P-1 Black .

Map and Information

2'-7 1/2" 2'-7 (Map Artwork Not In Designer’s Scope) 2'-6" max message height 3/4"

Map Module, Insert 14 Scale : 1 1/2” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.14 INTERIOR SIGNS Section 6

1A 01 Information

INT.03.1 Overhead Destination, Large 1 Scale : 1/2” = 1’ - 0”

1D 11 Cafeteria

Alternate Layout 2 Scale : 1/2” = 1’ - 0”

INT.03.1 Overhead Destination, Large Suspended ceiling-mounted single- or double-sided sign used to identify major patient/visitor destinations in locations where unable to provide accompanying wall-mounted signs and descriptive text is necessary . For standard conditions, use sign type INT 03. .2 . When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers . Maintain 84” clearance or greater at all locations . Use only where visibility is not compromised .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.15 INTERIOR SIGNS Section 6

INT.03.1 6'-0" Overhead Destination, Large

1 . Accoustical tee bar “Twist On” 3" 5/Page 6.24 3" fixture as provided by Erico International Corporation 1 (Part No . 4G16 .) Mounted to accoustical ceiling tee bar

9" and mechanically fastened to 2 aluminum sub-frame .

3 ERICO International Corporation Front Elevation 34600 Solon Road 3 Scale : 1/2” = 1’ - 0” Solon, Ohio 44139 440 .248 0100. 440 .248 0723. Fax www erico. com.

2 . Message Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to sub-frame in field .

1 3 . Sub-frame to be standard 1/8” clear anodized aluminum channel 2 1/8" 1" 1/8" with mitred corners . Pre-drill holes to receive threaded stud 2 from “Twist On” fixture . Inset 1/2” 1 from edge of Message Panel on sides and bottom .

4 . Applied vinyl text and symbols to 2 match V-2 White . Font: Helvetica 8 1/2" LT Std Roman . 9"

5 . Applied vinyl oval with wedded- 3 out text . Font: ITC Officina Sans Std Bold 3 2 6 . Complete assembly to be located with 7’- 0” minimum to bottom A.F.F. (per A.D.A.)

Awarded signage contractor is responsible for verifying all overhead mounting locations Side Elevation Side Section and to ensure that visibility of 4 Scale : Half-Sized 5 Scale : Full Size sign is not visually blocked by EXIT lights, sprinkler heads, emergency devices or any other obstruction--and to ensure that mounting locations do not violate code compliance distances for any equipment, per the NAFPA (National Fire Protection Association) or any other governing codes. Any specific locations of concern to be addressed in the field with the owner/design/signage contractor at the time of install.

Signage contractor can reference the latest and most recent version of the NAFP Section 13; Installation Requirements as shown in Section 3.37 of this Master Plan.

For any message requiring a sign longer than 6’-0”, provide layout for approval prior to fabrication.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.16 INTERIOR SIGNS Section 6

INT.03.1 Overhead Destination, Large

EQ 8 1/2" 2" 10" 2" 3'-9" max message length EQ 1 . Accoustical tee bar “Twist On” 7/Page 6.25 fixture as provided by Erico International Corporation (Part No . 4G16 .) Mounted to accoustical ceiling tee bar 1A Message Text and mechanically fastened to 01 aluminum sub-frame .

Front & Back Message Panels ERICO International Corporation 34600 Solon Road 6 Scale : 1/2” = 1’ - 0” Solon, Ohio 44139 440 .248 0100. 440 .248 0723. Fax www erico. com. 8 1/2" 2" 10" 2" 2 . Message Panel to be 1/8” rigid PVC board Sintra in standard 4 black . Permanently attached to sub-frame in field . 1"

4 3 . Sub-frame to be standard 1/8”

7" clear anodized aluminum channel 3 1/4" 5 5/8" 1A Message Text 3" with mitred corners . Pre-drill holes to receive threaded stud 2" 1" 01 from “Twist On” fixture . Inset 1/2” from edge of Message Panel on 5 sides and bottom . Message Detail 4 . Applied vinyl text and symbols to 7 Scale : 1” = 1’ - 0” match V-2 White . Font: Helvetica LT Std Roman .

5 . Applied vinyl oval with wedded- out text . Font: ITC Officina Sans Std Bold EQ 8 1/2" 2" 10" 2" 3'-9" max message length EQ 6 . Complete assembly to be located with 7’- 0” minimum to 1 1/2" 9/Page 6.25 bottom A.F.F. (per A.D.A.)

Awarded signage contractor 1H Sym Message Text is responsible for verifying all 12 overhead mounting locations and to ensure that visibility of sign is not visually blocked by Front & Back Message Panels EXIT lights, sprinkler heads, 8 Scale : 1/2” = 1’ - 0” emergency devices or any other obstruction--and to ensure that mounting locations do not violate code compliance distances for any equipment, 8 1/2" 2" 10" 2" 1 1/2" per the NAFPA (National Fire Protection Association) or any other governing codes. Any specific locations of concern 4 to be addressed in the field 1" with the owner/design/signage 4 contractor at the time of install.

7" 3 1/4" 5 5/8" 1H Sym Message 3" Signage contractor can reference the latest and most 2" 1" 12 recent version of the NAFP Section 13; Installation 5 Requirements as shown in Section 3.37 of this Master Plan. Message Detail 9 Scale : 1” = 1’ - 0” For any message requiring a sign longer than 6’-0”, provide layout for approval prior to fabrication.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.17 INTERIOR SIGNS Section 6

1D 13

INT.03.2 Overhead Destination, Small 1 Scale : 1/2” = 1’ - 0”

Alternate Layouts 2 Scale : 1/2” = 1’ - 0”

INT.03.2 Overhead Destination, Small Suspended ceiling-mounted double-sided sign used to identify major patient/visitor destinations . For destinations other than restrooms, provide an accompanying wall-mounted destination sign, sign types INT 04. 1. or INT 04. .2 . For restrooms, provide an accompanying wall-mounted restroom identity, sign type INT 13. . When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers . Maintain 84” clearance or greater at all locations . Use only where visibility is not compromised .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.18 INTERIOR SIGNS Section 6

INT.03.2 Overhead Destination, Small

2'-0" 1 . Accoustical tee bar “Twist On” fixture as provided by Erico International Corporation 3" 5/Page 6.27 3" (Part No . 4G16 .) Mounted to accoustical ceiling tee bar and mechanically fastened to 1 aluminum sub-frame .

9" ERICO International Corporation 2 34600 Solon Road Solon, Ohio 44139 440 .248 0100. 3 440 .248 0723. Fax 3 Front Elevation www erico. com. Scale : 1” = 1’ - 0” 2 . Message Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to sub-frame in field .

3 . Sub-frame to be standard 1/8” clear anodized aluminum channel 1 with mitred corners . Pre-drill holes to receive threaded stud 2 1/8" 1" 1/8" from “Twist On” fixture . Inset 1/2” from edge of Message Panel on sides and bottom . 2 1 4 . Applied vinyl text and symbols to match V-2 White . Font: Helvetica LT Std Roman .

2 5 . Applied vinyl oval with wedded- 8 1/2"

9" out text . Font: ITC Officina Sans Std Bold 3 6 . Complete assembly to be 3 located with 7’- 0” minimum to 2 bottom A.F.F. (per A.D.A.) Awarded signage contractor is responsible for verifying all overhead mounting locations and to ensure that visibility of sign is not visually blocked by Side Elevation Side Section EXIT lights, sprinkler heads, emergency devices or any other 4 Scale : Half-Sized 5 Scale : Full Size obstruction--and to ensure that mounting locations do not violate code compliance distances for any equipment, per the NAFPA (National Fire Protection Association) or any other governing codes. Any specific locations of concern to be addressed in the field with the owner/design/signage contractor at the time of install.

Signage contractor can reference the latest and most recent version of the NAFP Section 13; Installation Requirements as shown in Section 3.37 of this Master Plan.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.19 INTERIOR SIGNS Section 6

INT.03.2 Overhead Destination, Small 1 1/2" 8 1/2" 2" 10" 2" 1 . Accoustical tee bar “Twist On” fixture as provided by Erico International Corporation (Part No . 4G16 .) Mounted to 1" accoustical ceiling tee bar and mechanically fastened to

7" aluminum sub-frame . 3 1/4" 5 5/8" 1D 4 ERICO International Corporation 1" 13 34600 Solon Road Solon, Ohio 44139 5 440 .248 0100. 440 .248 0723. Fax Front & Back Message Panels www erico. com. 6 Scale : 1” = 1’ - 0” 2 . Message Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to sub-frame in field .

3 . Sub-frame to be standard 1/8” clear anodized aluminum channel 1 1/2" 1'-9" max symbol area 1 1/2" with mitred corners . Pre-drill holes to receive threaded stud from “Twist On” fixture . Inset 1/2” from edge of Message Panel on

1" sides and bottom .

4 . Applied vinyl text and symbols to 7" 4 match V-2 White . Font: Helvetica LT Std Roman . 1" 5 . Applied vinyl oval with wedded- out text . Font: ITC Officina Sans Front & Back Message Panels Std Bold 7 Scale : 1” = 1’ - 0” 6 . Complete assembly to be located with 7’- 0” minimum to bottom A.F.F. (per A.D.A.)

Awarded signage contractor is responsible for verifying all 1 1/2" 1'-9" max symbol area 1 1/2" overhead mounting locations and to ensure that visibility of EQ 4" EQ sign is not visually blocked by EXIT lights, sprinkler heads, emergency devices or any other

1" obstruction--and to ensure that mounting locations do not violate code compliance

7" distances for any equipment, 4 per the NAFPA (National Fire Protection Association) or any 1" other governing codes. Any specific locations of concern to be addressed in the field Front & Back Message Panels with the owner/design/signage contractor at the time of install. 8 Scale : 1” = 1’ - 0” Signage contractor can reference the latest and most recent version of the NAFP Section 13; Installation Requirements as shown in Section 3.37 of this Master Plan.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.20 INTERIOR SIGNS Section 6

INT.03.3 Overhead Destination, Large -- Aluminum Letters 1 Scale : 1/2” = 1’ - 0”

INT.03.3 Overhead Destination, Large -- Aluminum Letterforms Wall-mounted, brushed aluminum letterforms used to identify major patient/visitor destinations . where great visibility is required, to direct to a specific destination or to label a portal door . This sign may be used to direct for multiple directions, but must have a minimum of 3” high copy to satisfy ADA requirements . When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers . Maintain 84” clearance or greater at all locations . Use only where visibility is not compromised

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.21 INTERIOR SIGNS Section 6

INT.03.3 8 1/2" 2" 10" 2" 3'-9" max message length Overhead Destination, Large-- 3/Page 7.22 Aluminum Letterforms

1 . Oval to be 1/4” thick horizontally brushed aluminum, with 1A Message Text 01 bead-blasted returns . Text to be photochemically etched and paint infilled to match Front Elevation P-15 Exterior Metallic Silver-Grey . Font: ITC Officina Sans Std Bold 2 Scale : 1/2” = 1’ - 0” 2 . Text and symbols to be 1/4” thick horizontally brushed aluminum, with bead-blasted returns . Font: Helvetica LT Std Roman .

3 . Text to be 1/4” thick horizontally brushed aluminum, with bead- blasted returns . 8 1/2" 2" 10" 2" Font: Helvetica LT Std Roman .

4 . Complete assembly to be 2 mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive, centered top-to- 3 bottom on existing 7" 3 1/4" 5 5/8" 1A 01 Message Text 3" architectural soffit . 1 Message Detail 3 Scale : 1” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.22 INTERIOR SIGNS Section 6

1.EC.81.8.A-C

Ambulatory Care Emergency Services Nursing Administration

1H 08

INT.04.1 Destination, Large 1 Scale : Half-Sized

INT.04.1 Destination, Large Wall-mounted sign used to identify major patient/visitor destinations with 5-7 lines of text . Provide an accompanying ceiling-mounted overhead destination sign, sign type INT 03. .2 .

For destinations with less than 5 lines of text, use sign type INT 04. .2 .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.23 INTERIOR SIGNS Section 6

INT.04.1 9" Destination, Large

1/4" 8 1/2" 1/4" 1 . Room Number Panel to be 059”. interior photopolymer painted 1/4" to match P-1 Black . Permanently attached to Middle Panel .

2 . Text Panel to be 052”. Rowmark 2 1/4" 1 Lasermark engraving material to match 922-344 Smooth Silver / Black . Permanently attached to Middle Panel .

2 Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974

1'-0" 3 www .rowmark com.

3 . Middle Panel to be 1/4” rigid PVC 9 1/4" board Sintra in standard black . 4 Permanently attached to Back Panel .

4 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle

1/4" Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

Front Elevation 5 . Raised text painted to match P-2 White . Grade 2 Braille left 2 Scale : 3” = 1’ - 0” unpainted . Font: Helvetica LT Std Roman .

6 . Laser engraved text . Font: 1/4" 1/8" Helvetica LT Std Bold .

7 . Laser engraved oval to leave text . Font: ITC Officina Sans Std Bold .

1/4" 8 . Laser engraved text . Font: 1 Helvetica LT Std Roman . 9 . Complete assembly to be

2 1/4" mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side of door . 2

1'-0" 3 9 1/4"

4 1/4"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.24 INTERIOR SIGNS Section 6

INT.04.1 1/2" 7 1/2" max message length 1/2" Destination, Large

1 . Room Number Panel to be 059”. interior photopolymer painted

1 1/4" to match P-1 Black . Permanently 5/8" ROOM NUMBER TEXT 5 attached to Middle Panel . 5/8" 2 . Text Panel to be 052”. Rowmark Lasermark engraving material to Room Number Panel match 922-344 Smooth Silver / 4 Scale : 3” = 1’ - 0” Black . Permanently attached to Middle Panel .

Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974 www .rowmark com. 1/2" 7 1/2" max message length 1/2" 3 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . 1" Single Destination Text Permanently attached to Back 6 Panel . 7/8" 1/2" Single Destination Text 4 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . 1 1/4" Multiple Destination Text Inset 1/2” from edge of Middle

7/8" Panel on all four sides . Provide 1/2" Multiple Destination Text vinyl backup plate to match V-5 Silver for glass-mount conditions .

7 5 . Raised text painted to match P-2 White . Grade 2 Braille left 8 unpainted . Font: Helvetica LT Std Roman .

5/8" 6 . Laser engraved text . Font: 1 1/2" 1 1/8" 1H Helvetica LT Std Bold .

5/8" 08 7 . Laser engraved oval to leave text . 1/2" 1 3/4" 2 1/4" Font: ITC Officina Sans Std Bold . 1/4" 1/2" 8 . Laser engraved text . Font: Text Panel Helvetica LT Std Roman .

5 Scale : 3” = 1’ - 0” 9 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side of door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.25 INTERIOR SIGNS Section 6

1.EC.45.1

Emergency Center Patient Check-In 1D 13

INT.04.2A Destination, Small 1 Scale : 6” = 1’ - 0”

INT.04.2A Destination, Small - Wall Mounted Wall-mounted sign used to identify major patient/visitor destinations with 1-4 lines of text. Provide an accompanying ceiling-mounted overhead destination sign, sign type INT.03.2.

For destinations with more than 4 lines of text, use sign type INT.04.1.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.26 INTERIOR SIGNS Section 6

9" INT.04.2A Destination, Small - 1/4" 8 1/2" 1/4" Wall Mounted

1/4" 1. Room Number Panel to be .059” interior photopolymer painted to match P-1 Black. Permanently attached to Middle Panel. 2 1/4" 1 2. Text Panel to be .052” Rowmark Lasermark engraving material to match 922-344 Smooth Silver / Black. Permanently attached to 2 Middle Panel. 8 3/4" Rowmark, LLC

6" 3 2040 Industrial Drive Findlay, Ohio 45840 419.425.8974 www.rowmark.com 4

1/4" 3. Middle Panel to be 1/4” rigid PVC board Sintra in standard black. Permanently attached to Back Panel. Front Elevation 2 4. Back Panel to be 1/8” rigid PVC Scale : 3” = 1’ - 0” board Sintra in standard black. Inset 1/2” from edge of Middle 1/4" 1/8" Panel on all four sides.

5. Raised text painted to match P-2 White. Grade 2 Braille left unpainted. Font: Helvetica LT Std Roman. 1/4" 1 6. Laser engraved text. Font: Helvetica LT Std Bold. 2 1/4" 7. Laser engraved oval to leave text. .

8. Laser engraved text. Font: 2 Helvetica LT Std Roman. 9. Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from

8 3/4" strike side of door. 3 6"

4 1/4"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.27 INTERIOR SIGNS Section 6

1.EC.45.1

Emergency Center Patient Check-In 1D 13

INT.04.2B Destination, Small 1 Scale : 6” = 1’ - 0”

INT.04.2B Destination, Small - Glass Mounted Wall-mounted sign used to identify major patient/visitor destinations with 1-4 lines of text. Provide an accompanying ceiling-mounted overhead destination sign, sign type INT.03.2.

For destinations with more than 4 lines of text, use sign type INT.04.1.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.28 INTERIOR SIGNS Section 6

9" INT.04.2B Destination, Small - 1/4" 8 1/2" 1/4" Glass Mounted 4"

1 / 1. Room Number Panel to be .059” interior photopolymer painted to match P-1 Black. Permanently attached to Middle Panel. 4" 2 1 / 1 2. Text Panel to be .052” Rowmark Lasermark engraving material to match 922-344 Smooth Silver / Black. Permanently attached to 2 Middle Panel. 4" 8 3 / Rowmark, LLC

6" 3 2040 Industrial Drive Findlay, Ohio 45840 419.425.8974 www.rowmark.com 4 4"

1 / 3. Middle Panel to be 1/4” rigid PVC board Sintra in standard black. Permanently attached to Back Panel. Front Elevation 2 4. Back Panel to be 1/8” rigid PVC Scale : 3” = 1’ - 0” board Sintra in standard black. Inset 1/2” from edge of Middle 1/4" 1/8" Panel on all four sides.

5. Provide vinyl backup plate to match V-5. Silver for glass-mount conditions. 4" 1 / 1 6. Raised text painted to match P-2 White. Grade 2 Braille left

4" unpainted. Font: Helvetica LT Std

2 1 / Roman.

7. Laser engraved text. Font: Helvetica LT Std Bold. 2 8. Laser engraved oval to leave text. .

9. Laser engraved text. Font: Helvetica LT Std Roman.

4" 10. Complete assembly to be /

8 3 mounted with low-VOC thin-mil VHB Tape and low-VOC silicone 3 adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from

6" strike side of door.

4 4" 1 /

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.28A INTERIOR SIGNS Section 6

INT.04.2 1/2" 7 1/2" max message length 1/2" Destination, Small

1 . Room Number Panel to be 059”. interior photopolymer painted 1 1/4"

5/8" ROOM NUMBER TEXT 5 to match P-1 Black . Permanently attached to Middle Panel . 5/8"

2 . Text Panel to be 052”. Rowmark Room Number Panel Lasermark engraving material to match 922-344 Smooth Silver / 4 Scale : 3” = 1’ - 0” Black . Permanently attached to Middle Panel .

Rowmark, LLC 2040 Industrial Drive 1/2" 7 1/2" max message length 1/2" Findlay, Ohio 45840 419 .425 .8974 www .rowmark com. 1" Single Destination Text 6 3 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . 7/8" 1/2" Single Destination Text Permanently attached to Back 7 Panel . 1 1/4" Multiple Destination Text 4 . Back Panel to be 1/8” rigid PVC 1/2" 8 board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide 5/8" 1 1/2" 1 1/8" 1D vinyl backup plate to match V-5

5/8" 13 Silver for glass-mount conditions .

1/2" 5 . Raised text painted to match 1 3/4" 2 1/4" P-2 White . Grade 2 Braille left 1/4" 1/2" unpainted . Font: Helvetica LT Std Text Panel Roman . 5 Scale : 3” = 1’ - 0” 6 . Laser engraved text . Font: Helvetica LT Std Bold .

7 . Laser engraved oval to leave text . Font: ITC Officina Sans Std Bold .

8 . Laser engraved text . Font: Helvetica LT Std Roman .

9 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side of door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.29 INTERIOR SIGNS Section 6

INT.05 Elevator Identity, Overhead

1 . Accoustical tee bar “Twist On” fixture as provided by Erico International Corporation (Part No . 4G16 .) Mounted to accoustical ceiling tee bar and mechanically fastened to aluminum sub-frame .

Blue ERICO International Corporation 34600 Solon Road Solon, Ohio 44139 440 248. 0100. 440 248. 0723. Fax www erico. com.

2 . Message Panel to be 1/8” rigid PVC board Sintra in standard black . Green Elevators Painted according to elevator designation as described below . Permanently attached to sub-frame in field . Message the same on front and back of sign .

3 . Sub-frame to be standard 1/8” clear anodized aluminum channel with mitred corners . Pre-drill holes to receive threaded stud from “Twist Purple Elevators On” fixture . Inset 1/2” from edge of Message Panel on sides and bottom .

4 . Applied vinyl text and symbols . Color according to elevator designation as described below . Font: Helvetica LT Std Bold .

Pink Elevators 5 . Complete assembly to be located with 7’- 0” minimum to bottom A.F.F. (per A.D.A.)

Awarded signage contractor is responsible for verifying all overhead mounting locations, per previous Master Plan notes. Brown Elevators COLOR DESIGNATIONS:

BLUE Painted to match P-7 Blue . Vinyl to match V-2 White .

GREEN Painted to match P-8 Green . Orange Elevators Vinyl to match V-2 White .

PURPLE Painted to match P-6 Purple . Vinyl to match V-2 White .

PINK Painted to match P-9 Pink . Yellow Elevators Vinyl to match V-2 White . BROWN Painted to match P-10 Brown . Vinyl to match V-2 White . Color Options ORANGE 2 Scale : 1” = 1’ - 0” Painted to match P-5 Orange . Vinyl to match V-2 White .

YELLOW Painted to match P-4 Yellow . Vinyl to match V-1 Black .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.30 INTERIOR SIGNS Section 6

Blue Elevators

INT.05 Elevator Identity, Overhead 1 Scale : 1/2” = 1’ - 0”

INT.05 Elevator Identity, Overhead Suspended ceiling-mounted double-sided sign used to identify public elevator lobbies. Signs painted according to elevator color designation.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.31 INTERIOR SIGNS Section 6

INT.05 Elevator Identity, Overhead

3'-0" field verify 1. Accoustical tee bar “Twist On” fixture as provided by Erico International Corporation (Part 3" 5/Page 6.37 3" No. 4G16.) Mounted to accoustical ceiling tee bar and mechanically fastened to aluminum sub-frame.

1 ERICO International Corporation 34600 Solon Road 9" 2 Solon, Ohio 44139 440.248.0100 440.248.0723 Fax www.erico.com 3 Front Elevation 2. Message Panel to be 1/8” rigid PVC 3 board Sintra in standard black. Scale : 1” = 1’ - 0” Painted according to elevator designation as described below. Permanently attached to sub-frame in field. Message the same on front and back of sign.

3. Sub-frame to be standard 1/8” clear anodized aluminum channel with 1 mitred corners. Pre-drill holes to receive threaded stud from “Twist 2 1/8" 1" 1/8" On” fixture. Inset 1/2” from edge of Message Panel on sides and bottom. 2 1 4. Applied vinyl text and symbols. Color according to elevator designation as described below. Font: Helvetica LT Std Bold. 2

8 1/2" 5. Complete assembly to be located 9" with 7’- 0” minimum to bottom 3 A.F.F. (per A.D.A.) Awarded signage contractor 3 is responsible for verifying all 2 overhead mounting locations, per previous Master Plan notes.

COLOR DESIGNATIONS:

BLUE Side Elevation Side Section Painted to match P-7 Blue. Vinyl to match V-2 White. 4 Scale : Half-Sized 5 Scale : Full Size GREEN Painted to match P-8 Green. Vinyl to match V-2 White.

PURPLE Painted to match P-6 Purple. Vinyl to match V-2 White. 2 1/2" 3 1/4" 2" 2'-1 3/4" max message length 2 1/2" PINK Painted to match P-9 Pink. Vinyl to match V-2 White.

4" BROWN 7 1 /

5 1/2" Painted to match P-10 Brown.

2" Elevator Identity Text 4 Vinyl to match V-2 White.

ORANGE Painted to match P-5 Orange. Front & Back Message Panels Vinyl to match V-2 White. 6 Scale : 1” = 1’ - 0” YELLOW Painted to match P-4 Yellow. Vinyl to match V-1 Black.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.31A INTERIOR SIGNS Section 6

Blue Elevators Level 1

INT.06 Elevator Identity, Wall-Mounted 1 Scale : 1/2” = 1’ - 0”

INT.06 Elevator Identity, Wall-Mounted Wall-mounted sign used to identify public elevator lobbies . Signs painted according to elevator color designation .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.32 INTERIOR SIGNS Section 6

INT.06 Elevator Identity, Wall-Mounted

1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Painted according to Blue Elevators elevator designation as described below . Permanently attached to Level 1 Back Panel . 2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1” from edge of Message Panel on all four sides .

Green Elevators 3 . Applied vinyl text and symbols . Color according to elevator Level 1 designation as described below . Font: Helvetica LT Std Bold .

4 . Applied vinyl text . Color according to elevator designation as described below . Font: Purple Elevators Helvetica LT Std Roman . Level 1 5 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Top of sign aligned with top of elevator door frame . Centered between elevator Pink Elevators doors .

Level 1 COLOR DESIGNATIONS:

BLUE Painted to match P-7 Blue . Vinyl to match V-2 White .

Brown Elevators GREEN Painted to match P-8 Green . Level 1 Vinyl to match V-2 White . PURPLE Painted to match P-6 Purple . Vinyl to match V-2 White .

PINK Orange Elevators Painted to match P-9 Pink . Level 1 Vinyl to match V-2 White . BROWN Painted to match P-10 Brown . Vinyl to match V-2 White .

ORANGE Yellow Elevators Painted to match P-5 Orange . Vinyl to match V-2 White .

Level 1 YELLOW Painted to match P-4 Yellow . Vinyl to match V-1 Black . Color Options 2 Scale : 1” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.33 INTERIOR SIGNS Section 6

INT.06 Elevator Identity, 3'-0" Wall-Mounted

1" 2'-10" 1" 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard 1" black . Painted according to elevator designation as described below . Permanently attached to 1 Back Panel . 7" 9"

2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black .

1" 2 Inset 1” from edge of Message Front Elevation Panel on all four sides .

3 Scale : 1” = 1’ - 0” 3 . Applied vinyl text and symbols . Color according to elevator designation as described below . Font: Helvetica LT Std Bold . 1/4" 1/8" 4 . Applied vinyl text . Color according to elevator designation as described below . Font: Helvetica LT Std Roman . 1" 5 . Complete assembly to be mounted with low-VOC thin-mil 1 VHB Tape and low-VOC silicone adhesive . Top of sign aligned with top of elevator door frame . Centered between elevator doors .

COLOR DESIGNATIONS: 7" 9"

BLUE Painted to match P-7 Blue . Vinyl to match V-2 White .

GREEN Painted to match P-8 Green . 2 Vinyl to match V-2 White .

PURPLE

1" Painted to match P-6 Purple . Vinyl to match V-2 White .

PINK Painted to match P-9 Pink . Side Elevation Vinyl to match V-2 White . 4 Scale : Half-Sized BROWN Painted to match P-10 Brown . Vinyl to match V-2 White .

ORANGE 2 1/2" 3 1/4" 2" 2'-1 3/4" max message length 2 1/2" Painted to match P-5 Orange . Vinyl to match V-2 White . 1 3/4"

YELLOW 3 3/4" 2" Elevator Identity Text 3 Painted to match P-4 Yellow . Vinyl to match V-1 Black . 5 1/2"

3 1/2" Level Identity Text 4

Message Panel 5 Scale : 1” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.34 INTERIOR SIGNS Section 6

1'-2"

1A Emergency 1'-2"

1A 20-35 1'-1 7/8" 1'-1 1A Emergency 1A 01-19 1B 1C 1E 1A 20-35

1A 01-19 INT.07.2 Wall Directional, Medium

1'-10" 1B 1C 1E 2 Scale : 1 1/2” = 1’ - 0” Blue Elevators Orange Elevators Restrooms

1'-2"

INT.07.1 Wall Directional, Large 1A 20-35 1 Scale : 1 1/2” = 1’ - 0”

9" Exit to Lobby

INT.07.3 Wall Directional, Small 3 Scale : 1 1/2” = 1’ - 0”

This manual contains three options for an interchangeable wall-mounted sign used to direct to public destinations. Use the smallest sign possible to accommodate the message while still providing flexibility for future changes or additions to messages .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.35 INTERIOR SIGNS Section 6

1A Emergency

1A 20-35

1A 01-19 1B 1C 1E Blue Elevators Orange Elevators Restrooms

INT.07.1 Wall Directional, Large 1 Scale : 3” = 1’ - 0”

INT.07.1 Wall Directional, Large A changeable wall-mounted sign used to direct to public destinations with 8-12 lines . This sign will be necessary primarily on the ground level, where there are multiple destinations, or at major decisions points along public pathways .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.36 INTERIOR SIGNS Section 6

INT.07.1 1'-2" Wall Directional, Large 1/2" 1'-1" 1/2" 1 . Header Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to Middle

1/2" Panel .

1 2 . Aluminum “C” channel as provided 1 1/2" by The JRS Company (Part No . 29) 2 in satin silver finish . Permanently attached to Middle Panel . 1 5/8" 3 The JRS Company 544 North Rimsdale Avenue Box 2035

1 5/8" 4 Covina, CA 91722 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com. 1 5/8"

3 . Emergency Insert to be 052”. Rowmark Lasermark engraving

1 5/8" material to match 922-602 Red / White . Adhere into “C” channel with film tape .

1 5/8" Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974 1 5/8" www .rowmark com.

4 . Message Insert to be 052”. 2'-1/2"

1 5/8" Rowmark Lasermark engraving material to match 922-344 Smooth Silver / Black . Adhere into “C” channel with film tape . 1 5/8" 5 . Aluminum “C” channel as provided by The JRS Company (Part No . 36) in satin silver finish . Permanently 1 5/8" attached to Middle Panel .

6 . Information Insert to be 052”.

1 5/8" Rowmark Lasermark engraving material to match 922-344 Smooth Silver / Black . Adhere into “C” channel with film tape . 1 5/8" 7 . Middle Panel to be 1/2” rigid PVC board Sintra in standard black . Permanently attached to Back 1 5/8" 1 Panel .

3/8" 5 8 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on 2 1/8" 6 all four sides . Provide vinyl backup plate to match V-5 Silver for glass-

1/2" 7 mount conditions .

9 . Laser engraved text and symbol . Front Elevation Font: Helvetica LT Std Bold .

2 Scale : 3” = 1’ - 0” 10 . Laser engraved oval to leave text . Font: ITC Officina Sans Std Bold .

11 . Laser engraved text and symbol . Font: Helvetica LT Std Roman .

12 . Laser engraved text and symbol . Font: Helvetica LT Std Oblique .

13 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.37 INTERIOR SIGNS Section 6

INT.07.1 1/2" Wall Directional, Large 3/16" 1/8" 1 . Header Panel to be 1/8” rigid PVC board Sintra in standard black . 1/8" Permanently attached to Middle Panel .

2 . Aluminum “C” channel as provided by The JRS Company (Part No . 29) in satin silver finish . Permanently 1/2" attached to Middle Panel .

1 The JRS Company 544 North Rimsdale Avenue

1 1/2" Box 2035 Covina, CA 91722 626 .967 .2432 2 626 .966 0714. Fax www .jrscoinc com.

3 . Emergency Insert to be 052”.

1 1/2" Rowmark Lasermark engraving 1 5/8" 3 material to match 922-602 Red / White . Adhere into “C” channel with film tape .

Rowmark, LLC 2040 Industrial Drive 4 Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

4 . Message Insert to be 052”. Rowmark Lasermark engraving material to match 922-344 Smooth 2'-1/2" Silver / Black . Adhere into “C” channel with film tape .

5 . Aluminum “C” channel as provided by The JRS Company (Part No . 36) in satin silver finish . Permanently attached to Middle Panel .

6 . Information Insert to be 052”. Rowmark Lasermark engraving 1 material to match 922-344 Smooth Silver / Black . Adhere into “C” channel with film tape . 3/8" 5 7 . Middle Panel to be 1/2” rigid PVC board Sintra in standard black . 6 Permanently attached to Back Panel . 2" 2 1/8" 7 8 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on 8 all four sides . Provide vinyl backup plate to match V-5 Silver for glass-

1/2" mount conditions .

9 . Laser engraved text and symbol . Font: Helvetica LT Std Bold . Side Elevation 3 Scale : Half-Sized 10 . Laser engraved oval to leave text . Font: ITC Officina Sans Std Bold .

11 . Laser engraved text and symbol . Font: Helvetica LT Std Roman .

12 . Laser engraved text and symbol . Font: Helvetica LT Std Oblique .

13 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.38 INTERIOR SIGNS Section 6

INT.07.1 1'-1" Wall Directional, Large

1/2" 1/2" 1/2" 1/2" 1 . Header Panel to be 1/8” rigid PVC 1" 1 1/2" 8 1/2" max message length board Sintra in standard black . Permanently attached to Middle 1/2" Panel .

2 . Aluminum “C” channel as provided by The JRS Company (Part No . 29) in satin silver finish . Permanently 1" Symbol “Emergency” Text 3/4" 1 1/2" 1A 9 attached to Middle Panel . 10 The JRS Company

9/16" 544 North Rimsdale Avenue Emergency Insert Box 2035 4 Covina, CA 91722 Scale : 3” = 1’ - 0” 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com.

3 . Emergency Insert to be 052”. Rowmark Lasermark engraving material to match 922-602 Red / 1'-1" White . Adhere into “C” channel with film tape . 1/2" 1/2" 1/2" 1/2" 1" 1 1/2" 8 1/2" max message length Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

1" Message Text 3/4" 1 1/2" 1A 9 4 . Message Insert to be 052”. Rowmark Lasermark engraving 10 material to match 922-344 Smooth 9/16" Silver / Black . Adhere into “C” channel with film tape . 1"

1 1/2" 1B 1C 1D 1E 1F 10 5 . Aluminum “C” channel as provided by The JRS Company (Part No . 36) in satin silver finish . Permanently

9/16" attached to Middle Panel .

6 . Information Insert to be 052”.

1" Symbol Message Text Rowmark Lasermark engraving 3/4"

1 1/2" 9 material to match 922-344 Smooth Silver / Black . Adhere into “C” channel with film tape . Message Insert 7 . Middle Panel to be 1/2” rigid PVC 5 Scale : 3” = 1’ - 0” board Sintra in standard black . Permanently attached to Back Panel .

8 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on 3/8" 1/8" 1/2" 3/8" all four sides . Provide vinyl backup plate to match V-5 Silver for glass- 1" 1" 9 3/4" max message length mount conditions .

9 . Laser engraved text and symbol . English Information Message Text Font: Helvetica LT Std Bold . English Information Message Text 2" 1A 7/8" 5/8" 11 10 . Laser engraved oval to leave text . 01 English Information Message Text Font: ITC Officina Sans Std Bold . 10 11 . Laser engraved text and symbol . 11/32" Font: Helvetica LT Std Roman . 5/8" 1/4" 12 . Laser engraved text and symbol . 9 Font: Helvetica LT Std Oblique . English Information Message Text English Information Message Text 1/2" 1A 11 13 . Complete assembly to be mounted 01 English Information Message Text with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . 1/2" 12 Sign to be located at 5’- 0” to Information Insert center A .F .F . 6 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.39 INTERIOR SIGNS Section 6

1A Emergency

1A 20-35

1A 01-19 1B 1C 1E

INT.07.2 Wall Directional, Medium 1 Scale : 3” = 1’ - 0”

INT.07.2 Wall Directional, Medium A changeable wall-mounted sign used to direct to public destinations with 5-7 lines . This sign will be used in a variety of locations .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.40 INTERIOR SIGNS Section 6

INT.07.2 1'-2" Wall Directional, Medium 1/2" 1'-1" 1/2" 1 . Header Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to Middle Panel . 1/2" 1 2 . Aluminum “C” channel as provided by The JRS Company (Part No . 29) 1 1/2" in satin silver finish . Permanently 2 attached to Middle Panel .

1 5/8" The JRS Company 3 544 North Rimsdale Avenue Box 2035 Covina, CA 91722

1 5/8" 4 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com. 1 5/8" 3 . Emergency Insert to be 052”. Rowmark Lasermark engraving material to match 922-602 Red /

1 5/8" White . Adhere into “C” channel with film tape . 1'-4 3/8" Rowmark, LLC 1 5/8" 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974

1 5/8" www .rowmark com.

4 . Message Insert to be 052”. Rowmark Lasermark engraving

1 5/8" 1 material to match 922-344 Smooth Silver / Black . Adhere into “C” 3/8" 5 channel with film tape . 5 . Aluminum “C” channel as provided

2 1/8" 6 by The JRS Company (Part No . 36) in satin silver finish . Permanently attached to Middle Panel .

1/2" 7 6 . Information Insert to be 052”. Front Elevation Rowmark Lasermark engraving material to match 922-344 Smooth 2 Scale : 3” = 1’ - 0” Silver / Black . Adhere into “C” channel with film tape .

7 . Middle Panel to be 1/2” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

8 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass- mount conditions .

9 . Laser engraved text and symbol . Font: Helvetica LT Std Bold .

10 . Laser engraved oval to leave text . Font: ITC Officina Sans Std Bold .

11 . Laser engraved text and symbol . Font: Helvetica LT Std Roman .

12 . Laser engraved text and symbol . Font: Helvetica LT Std Oblique .

13 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.41 INTERIOR SIGNS Section 6

INT.07.2 Wall Directional, Medium

1/2" 1 . Header Panel to be 1/8” rigid PVC 3/16" 1/8" board Sintra in standard black . Permanently attached to Middle 1/8" Panel . 2 . Aluminum “C” channel as provided by The JRS Company (Part No . 29) in satin silver finish . Permanently attached to Middle Panel . 1/2" The JRS Company 1 544 North Rimsdale Avenue Box 2035 Covina, CA 91722 1 1/2" 626 .967 .2432 626 .966 0714. Fax 2 www .jrscoinc com. 3 . Emergency Insert to be 052”. Rowmark Lasermark engraving material to match 922-602 Red / 1 1/2"

1 5/8" 3 White . Adhere into “C” channel with film tape .

Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974 4 www .rowmark com.

4 . Message Insert to be 052”. Rowmark Lasermark engraving material to match 922-344 Smooth Silver / Black . Adhere into “C” channel with film tape . 1'-4 3/8"

5 . Aluminum “C” channel as provided by The JRS Company (Part No . 36) in satin silver finish . Permanently attached to Middle Panel .

6 . Information Insert to be 052”. Rowmark Lasermark engraving material to match 922-344 Smooth 1 Silver / Black . Adhere into “C” channel with film tape .

3/8" 7 . Middle Panel to be 1/2” rigid PVC 5 board Sintra in standard black . Permanently attached to Back 6 Panel .

2" 8 . Back Panel to be 1/8” rigid PVC 2 1/8" board Sintra in standard black . Inset 7 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup 8 plate to match V-5 Silver for glass- mount conditions . 1/2" 9 . Laser engraved text and symbol . Font: Helvetica LT Std Bold .

Side Elevation 10 . Laser engraved oval to leave text . Font: ITC Officina Sans Std Bold . 3 Scale : Half-Sized 11 . Laser engraved text and symbol . Font: Helvetica LT Std Roman .

12 . Laser engraved text and symbol . Font: Helvetica LT Std Oblique .

13 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.42 INTERIOR SIGNS Section 6

INT.07.2 1'-1" Wall Directional, Medium

1/2" 1/2" 1/2" 1/2" 1 . Header Panel to be 1/8” rigid PVC 1" 1 1/2" 8 1/2" max message length board Sintra in standard black . Permanently attached to Middle 1/2" Panel .

2 . Aluminum “C” channel as provided by The JRS Company (Part No . 29) in satin silver finish . Permanently 1" Symbol “Emergency” Text 3/4" 1 1/2" 1A 9 attached to Middle Panel . 10 The JRS Company

9/16" 544 North Rimsdale Avenue Emergency Insert Box 2035 4 Covina, CA 91722 Scale : 3” = 1’ - 0” 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com.

3 . Emergency Insert to be 052”. Rowmark Lasermark engraving material to match 922-602 Red / 1'-1" White . Adhere into “C” channel with film tape . 1/2" 1/2" 1/2" 1/2" 1" 1 1/2" 8 1/2" max message length Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

1" Message Text 3/4" 1 1/2" 1A 9 4 . Message Insert to be 052”. Rowmark Lasermark engraving 10 material to match 922-344 Smooth 9/16" Silver / Black . Adhere into “C” channel with film tape . 1"

1 1/2" 1B 1C 1D 1E 1F 10 5 . Aluminum “C” channel as provided by The JRS Company (Part No . 36) in satin silver finish . Permanently

9/16" attached to Middle Panel .

6 . Information Insert to be 052”.

1" Symbol Message Text Rowmark Lasermark engraving 3/4"

1 1/2" 9 material to match 922-344 Smooth Silver / Black . Adhere into “C” channel with film tape . Message Insert 7 . Middle Panel to be 1/2” rigid PVC 5 Scale : 3” = 1’ - 0” board Sintra in standard black . Permanently attached to Back Panel .

8 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on 3/8" 1/8" 1/2" 3/8" all four sides . Provide vinyl backup plate to match V-5 Silver for glass- 1" 1" 9 3/4" max message length mount conditions .

9 . Laser engraved text and symbol . English Information Message Text Font: Helvetica LT Std Bold . English Information Message Text 2" 1A 7/8" 5/8" 11 10 . Laser engraved oval to leave text . 01 English Information Message Text Font: ITC Officina Sans Std Bold . 10 11 . Laser engraved text and symbol . 11/32" Font: Helvetica LT Std Roman . 5/8" 1/4" 12 . Laser engraved text and symbol . 9 Font: Helvetica LT Std Oblique . English Information Message Text English Information Message Text 1/2" 1A 11 13 . Complete assembly to be mounted 01 English Information Message Text with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . 1/2" 12 Sign to be located at 5’- 0” to Information Insert center A .F .F . 6 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.43 INTERIOR SIGNS Section 6

1A 20-35 Exit to Lobby

INT.07.3 Wall Directional, Small 1 Scale : 3” = 1’ - 0”

INT.07.3 Wall Directional, Small A changeable wall-mounted sign used to direct to public destinations with 4 or fewer lines . This sign will be used primarily on the upper floors or where there are few destinations.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.44 INTERIOR SIGNS Section 6

INT.07.3 1'-2" Wall Directional, Small

1/2" 1'-1" 1/2" 1 . Header Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to Middle

1/2" Panel . 1

1 1/2" 2 . Aluminum “C” channel as 2 provided by The JRS Company (Part No . 29) in satin silver finish .

1 5/8" Permanently attached to Middle 3 Panel .

9" The JRS Company 1 5/8" 544 North Rimsdale Avenue Box 2035 Covina, CA 91722 1 5/8" 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com. 1 5/8" 3 . Message Insert to be 052”.

1/2" 4 Rowmark Lasermark engraving material to match 922-344 Front Elevation Smooth Silver / Black . Adhere into “C” channel with film tape . 2 Scale : 3” = 1’ - 0” Rowmark, LLC 2040 Industrial Drive 1/2" Findlay, Ohio 45840 419 .425 .8974 3/16" 1/8" www .rowmark com.

1/8" 4 . Middle Panel to be 1/2” rigid PVC board Sintra in standard black . Permanently attached to Back Panel . 1/2" 5 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . 1 Inset 1/2” from edge of Middle Panel on all four sides . Provide 1 1/2" vinyl backup plate to match V-5 Silver for glass-mount conditions .

2 6 . Laser engraved text and symbol . Font: Helvetica LT Std Bold . 1 1/2" 1 5/8" 3 7 . Laser engraved oval to leave text . Font: ITC Officina Sans Std Bold .

9" 8 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F .

4 5 1/2"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.45 INTERIOR SIGNS Section 6

INT.07.3 1'-1" Wall Directional, Small 1/2" 1/2" 1/2" 1/2" 1 . Header Panel to be 1/8” rigid PVC board Sintra in standard black . 1" 1 1/2" 8 1/2" max message length Permanently attached to Middle Panel .

2 . Aluminum “C” channel as 1" Message Text 3/4" 1 1/2" 1A 6 provided by The JRS Company (Part No . 29) in satin silver finish . 7 Permanently attached to Middle 9/16" Panel .

The JRS Company 1"

1 1/2" 1B 1C 1D 1E 1F 7 544 North Rimsdale Avenue Box 2035 Covina, CA 91722

9/16" 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com. 1" Symbol Message Text 3/4"

1 1/2" 6 3 . Message Insert to be 052”. Rowmark Lasermark engraving material to match 922-344 Smooth Silver / Black . Adhere into “C” channel with film tape . Message Text 3/4"

1 1/2" 6 Rowmark, LLC 2040 Industrial Drive Message Insert Findlay, Ohio 45840 419 .425 .8974 4 Scale : 3” = 1’ - 0” www .rowmark com.

4 . Middle Panel to be 1/2” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

5 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

6 . Laser engraved text and symbol . Font: Helvetica LT Std Bold .

7 . Laser engraved oval to leave text . Font: ITC Officina Sans Std Bold .

8 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.46 INTERIOR SIGNS Section 6

Emergency Restrooms

INT.08.1 Overhead Directional, 1-Line Suspended 1 Scale : 3/4” = 1’ - 0”

INT.08. 1 Overhead Directional, 1-Line Suspended A ceiling-hung sign, used where great visibility is required, to direct to a specific destination or to label a portal door . This sign may be used to direct for multiple directions, but must have a minimum of 3” high copy to satisfy ADA requirements . When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers . Maintain 84” clearance or greater at all locations . Use only where visibility is not compromised .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.47 INTERIOR SIGNS Section 6

INT.08.1 7'-8" Field Verify Overhead Directional, 1-Line Suspended

3" 3" 1 . Accoustical tee bar “Twist On” 4/Page 6.54 fixture as provided by Erico 1 International Corporation (Part No . 4G16 .) Mounted to accoustical ceiling tee bar 9" 2 and mechanically fastened to aluminum sub-frame . 3 Front Elevation ERICO International Corporation 34600 Solon Road 2 Scale : 1/2” = 1’ - 0” Solon, Ohio 44139 440 .248 0100. 440 .248 0723. Fax www erico. com.

2 . Message Panel to be 1/8” rigid PVC board Sintra in standard 1 black . Permanently attached to sub-frame in field . 1/8" 1" 1/8" 2 3 . Sub-frame to be standard 1/8” clear anodized aluminum channel 2 with mitred corners . Pre-drill 1 holes to receive threaded stud from “Twist On” fixture . Inset 1/2” from edge of Message Panel on sides and bottom . 2 8 1/2" 4 . Applied vinyl text and symbols 9" to match V-2 White and V-3 Red . 3 Font: Helvetica LT Std Roman . 5 . Complete assembly to be 3 located with 7’- 0” minimum to 2 bottom A.F.F. (per A.D.A.)

Awarded signage contractor is responsible for verifying all overhead mounting locations and to ensure that visibility of sign is not visually blocked by Side Elevation Side Section EXIT lights, sprinkler heads, 3 Scale : Half-Sized 4 Scale : Full Size emergency devices or any other obstruction--and to ensure that mounting locations do not violate code compliance distances for any equipment, per the NAFPA (National Fire Protection Association) or any other governing codes. Any specific locations of concern to be addressed in the field with the owner/design/signage contractor at the time of install.

Signage contractor can reference the latest and most recent version of the NAFP Section 13; Installation Requirements as shown in Section 3.37 of this Master Plan.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.48 INTERIOR SIGNS Section 6

INT.08.1 1 1/2" 3" 1" 3'-3" max message length 3'-3" max message length 1" 3" 1 1/2" Overhead Directional, 1-Line Suspended 3" 1 1/2" 3" 1 1/2" 1 . Accoustical tee bar “Twist On” fixture as provided by Erico International Corporation (Part No . 4G16 .) Mounted to 3" Message Text Message Text 4

2" accoustical ceiling tee bar and mechanically fastened to aluminum sub-frame . Front & Back Message Panel 5 Scale : 1/2” = 1’ - 0” ERICO International Corporation 34600 Solon Road Solon, Ohio 44139 440 .248 0100. 440 .248 0723. Fax www erico. com. 3" 2 . Message Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to sub-frame in field .

4 3 . Sub-frame to be standard 1/8” clear anodized aluminum channel with mitred corners . Pre-drill 3" holes to receive threaded stud from “Twist On” fixture . Inset 1/2” from edge of Message Panel on sides and bottom .

4 . Applied vinyl text and symbols to match V-2 White and V-3 Red . Arrow Font: Helvetica LT Std Roman . 6 Scale : Half-Sized 5 . Complete assembly to be located with 7’- 0” minimum to bottom A.F.F. (per A.D.A.)

Awarded signage contractor is responsible for verifying all overhead mounting locations and to ensure that visibility of sign is not visually blocked by EXIT lights, sprinkler heads, emergency devices or any other 4 obstruction--and to ensure that mounting locations do not violate code compliance 3" Symbol distances for any equipment, per the NAFPA (National Fire Protection Association) or any other governing codes. Any specific locations of concern to be addressed in the field with the owner/design/signage contractor at the time of install. Symbol 7 Scale : Half-Sized Signage contractor can reference the latest and most recent version of the NAFP Section 13; Installation Requirements as shown in Section 3.37 of this Master Plan.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.49 INTERIOR SIGNS Section 6

Emergency Restrooms

INT.08.2 Overhead Directional, 1-Line Wall-Mounted 1 Scale : 3/4” = 1’ - 0”

INT.08.2 Overhead Directional, 1-Line Wall-Mounted A wall-mounted sign, used where great visibility is required, to direct to a specific destination or to label a portal door . This sign may be used to direct for multiple directions, but must have a minimum of 3” high copy to satisfy ADA requirements . When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers . Maintain 84” clearance or greater at all locations . Use only where visibility is not compromised .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.50 INTERIOR SIGNS Section 6

INT.08.2 Overhead Directional, 7'-8" Field Verify 1-Line Wall-Mounted

1 . Message Panel to be 1/4” rigid PVC board Sintra in standard

9" 1 black . Permanently attached to Back Panel . 2 Front Elevation 2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . 2 Scale : 1/2” = 1’ - 0” Inset 1” from edge of Message Panel on all four sides .

3 . Applied vinyl text and symbols to match V-2 White and V-3 Red . Font: Helvetica LT Std Roman . 1/4" 1/8" 4 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located with 7’- 0” minimum to bottom A .F .F . 1"

1 7" 9"

2 1"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.51 INTERIOR SIGNS Section 6

INT.08.2 Overhead Directional, 1 1/2" 3" 1" 3'-3" max message length 3'-3" max message length 1" 3" 1 1/2" 1-Line Wall-Mounted

3" 1 1/2" 3" 1 1/2" 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

3" Message Text Message Text 3 2" 2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Front & Back Message Panel Inset 1” from edge of Message Panel on all four sides . 4 Scale : 1/2” = 1’ - 0” 3 . Applied vinyl text and symbols to match V-2 White and V-3 Red . Font: Helvetica LT Std Roman .

3" 4 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located with 7’- 0” minimum to bottom A .F .F . 3 3"

Arrow 5 Scale : Half-Sized

3

3" Symbol

Symbol 6 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.52 INTERIOR SIGNS Section 6

Emergency Restrooms Cafeteria

INT.08.3 Overhead Directional, 2-Line Suspended 1 Scale : 3/4” = 1’ - 0”

INT.08.3 Overhead Directional, 2-Line Suspended A ceiling-hung sign, used where great visibility is required, to direct to a specific destination or to label a portal door . This sign may be used to direct for multiple directions, but must have a minimum of 3” high copy to satisfy ADA requirements . When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers . Maintain 84” clearance or greater at all locations . Use only where visibility is not compromised . Use this sign only when conditions require 2 lines and ceiling height allows .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.53 INTERIOR SIGNS Section 6

INT.08.3 Overhead Directional, 2-Line Suspended 7'-8" Field Verify 1 . Accoustical tee bar “Twist On” fixture as provided by Erico 3" 3" International Corporation 4/Page 6.60 (Part No . 4G16 .) Mounted to 1 accoustical ceiling tee bar and mechanically fastened to aluminum sub-frame .

1'-0" 2 ERICO International Corporation 34600 Solon Road 3 Solon, Ohio 44139 Front Elevation 440 .248 0100. 2 Scale : 1/2” = 1’ - 0” 440 .248 0723. Fax www erico. com.

2 . Message Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to sub-frame in field . 1 3 . Sub-frame to be standard 1/8” 1/8" 1" 1/8" clear anodized aluminum channel 2 with mitred corners . Pre-drill holes to receive threaded stud 2 from “Twist On” fixture . Inset 1/2” 1 from edge of Message Panel on sides and bottom .

4 . Applied vinyl text and symbols 2 to match V-2 White and V-3 Red . 11 1/2" Font: Helvetica LT Std Roman . 1'-0" 3 5 . Complete assembly to be located with 7’- 0” minimum to 3 bottom A.F.F. (per A.D.A.) 2 Awarded signage contractor is responsible for verifying all overhead mounting locations and to ensure that visibility of sign is not visually blocked by EXIT lights, sprinkler heads, Side Elevation Side Section emergency devices or any other obstruction--and to ensure 3 Scale : Half-Sized 4 Scale : Full Size that mounting locations do not violate code compliance distances for any equipment, per the NAFPA (National Fire Protection Association) or any other governing codes. Any specific locations of concern to be addressed in the field with the owner/design/signage contractor at the time of install.

Signage contractor can reference the latest and most recent version of the NAFP Section 13; Installation Requirements as shown in Section 3.37 of this Master Plan.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.54 INTERIOR SIGNS Section 6

INT.08.3 Overhead Directional, 2-Line Suspended

1 . Accoustical tee bar “Twist On” fixture as provided by Erico 1 1/2" 3" 1" 3'-3" max message length 3'-3" max message length 1" 3" 1 1/2" International Corporation (Part No . 4G16 .) Mounted to 3" 1 1/2" 3" 1 1/2" accoustical ceiling tee bar and mechanically fastened to aluminum sub-frame . 5" 3" Message Text Message Text ERICO International Corporation

5" 34600 Solon Road 3" Message Text Message Text 4 Solon, Ohio 44139 440 .248 0100. 440 .248 0723. Fax Front & Back Message Panel www erico. com. 5 Scale : 1/2” = 1’ - 0” 2 . Message Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to sub-frame in field .

3" 3 . Sub-frame to be standard 1/8” clear anodized aluminum channel with mitred corners . Pre-drill holes to receive threaded stud from “Twist On” fixture . Inset 1/2” from edge of Message Panel on 4 sides and bottom .

4 . Applied vinyl text and symbols 3" to match V-2 White and V-3 Red . Font: Helvetica LT Std Roman .

5 . Complete assembly to be located with 7’- 0” minimum to bottom A.F.F. (per A.D.A.)

Arrow Awarded signage contractor is responsible for verifying all 6 Scale : Half-Sized overhead mounting locations and to ensure that visibility of sign is not visually blocked by EXIT lights, sprinkler heads, emergency devices or any other obstruction--and to ensure that mounting locations do not violate code compliance distances for any equipment, per the NAFPA (National Fire Protection Association) or any 4 other governing codes. Any specific locations of concern to be addressed in the field 3" Symbol with the owner/design/signage contractor at the time of install.

Signage contractor can reference the latest and most recent version of the NAFP Section 13; Installation Requirements as shown in Symbol Section 3.37 of this Master Plan. 7 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.55 INTERIOR SIGNS Section 6

INT.08.5 Overhead Directional, 2 Line Wall Mounted -- Aluminum Letters 1 Scale : 1/2” = 1’ - 0”

INT.08.5 Overhead Directional, 2-Line Wall Mounted -- Aluminum Letterforms Wall-mounted, brushed aluminum letterforms used to identify major patient/visitor destinations . where great visibility is required, to direct to a specific destination or to label a portal door . This sign may be used to direct for multiple directions, but must have a minimum of 3” high copy to satisfy ADA requirements . When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers . Maintain 84” clearance or greater at all locations . Use only where visibility is not compromised .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.56 INTERIOR SIGNS Section 6

INT.08.5 Overhead Directional, 2-Line Wall Mounted -- Aluminum Letterforms

1 . Arrow to be 1/4” thick 1 1/2" 3" 1" 3'-3" max message length 3'-3" max message length 1" 3" 1 1/2" horizontally brushed aluminum, with bead-blasted returns . 3" 1 1/2" 3" 1 1/2" 2 . Text to be 1/4” thick horizontally brushed aluminum, with bead- blasted returns . 3" Message Text Message Text Font: Helvetica LT Std Roman . 5"

3" Message Text Message Text 3 . Symbols to be 1/4” thick 1 horizontally brushed aluminum, Front Elevation with bead-blasted returns . 2 Applied vinyl text and symbols to 2 Scale : 1/2” = 1’ - 0” match V-2 White and V-3 Red as 3 needed for specialty symbols .

4 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone 3" adhesive, centered top-to- bottom on existing architectural soffit .

1 3"

Arrow Detail 3 Scale : Half-Sized

3

3" Symbol

Symbol Detail 4 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.57 INTERIOR SIGNS Section 6

2263

HYBRID OPERATING ROOM 2

INT.09 Typical Room Identity 1 Scale : Half-Sized

INT.09.1 Typical Room Identity - Wall Mounted A wall-mounted sign with raised copy and braille. Used to identify permanent rooms with fixed messages.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.58 INTERIOR SIGNS Section 6

INT.09.1 9" Typical Room Identity - Wall Mounted 1/4" 8 1/2" 1/4"

4" 1. Room Number Panel to be .059” 1 / interior photopolymer painted to match P-1 Black. Permanently attached to Middle Panel. 4"

2 1 / 1 2. Text Panel to be .052” Rowmark Lasermark engraving material to 2 match 922-402 Black / White. Permanently attached to Middle Panel. 7 5/8"

/8" Rowmark, LLC 4 7 2040 Industrial Drive 3 Findlay, Ohio 45840 419.425.8974 4 www.rowmark.com

3. Middle Panel to be 1/4” rigid PVC 4"

1 / board Sintra in standard black. Front Elevation Permanently attached to Back 2 Scale : 3” = 1’ - 0” Panel.

4. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle 1/4" 1/8" Panel on all four sides.

5. Raised text painted to match P-2 White. Grade 2 Braille left unpainted. Font: Helvetica LT Std

4" Roman. 1 /

1 6. Laser engraved text. Font: Helvetica LT Std Bold. 4" 2 1 / 7. Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from 2 strike side of door. 7 5/8" /8" 4 7 3

4 4" 1 /

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.59 INTERIOR SIGNS Section 6

INT.09 Typical Room Identity 1/2" 7 1/2" max message length 1/2" 1 . Room Number Panel to be 059”. interior photopolymer painted to match P-1 Black . Permanently

1 1/4" attached to Middle Panel . 5/8" ROOM NUMBER TEXT 5

5/8" 2 . Text Panel to be 052”. Rowmark Lasermark engraving material to match 922-402 Black / White . Room Number Panel Permanently attached to Middle 4 Scale : 3” = 1’ - 0” Panel .

Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 1/2" 7 1/2" max message length 1/2" 419 .425 .8974 www .rowmark com.

3 . Middle Panel to be 1/4” rigid PVC 1" Room Name Text 6 board Sintra in standard black . Permanently attached to Back 7/8" 1/2" Room Name Text Panel .

7/8" Room Name Text 4 . Back Panel to be 1/8” rigid PVC

7/8" Room Name Text board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

5 . Raised text painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman .

Text Panel 6 . Laser engraved text . Font: 5 Scale : 3” = 1’ - 0” Helvetica LT Std Bold .

7 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side of door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.60 INTERIOR SIGNS Section 6

2869

BLOOD BANK SUPERVISOR

INT.09 Typical Room Identity 1 Scale : Half-Sized

INT.09.2 Typical Room Identity - Glass Mounted A glass-mounted sign with raised copy and braille. Used to identify permanent rooms with fixed messages

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.60A INTERIOR SIGNS Section 6

INT.09.2 9" Typical Room Identity - Glass Mounted 1/4" 8 1/2" 1/4"

4" 1. Room Number Panel to be .059” 1 / interior photopolymer painted to match P-1 Black. Permanently attached to Middle Panel. 4"

2 1 / 1 2. Text Panel to be .052” Rowmark Lasermark engraving material to 2 match 922-402 Black / White. Permanently attached to Middle Panel. 7 5/8"

/8" Rowmark, LLC 4 7 2040 Industrial Drive 3 Findlay, Ohio 45840 419.425.8974 4 www.rowmark.com

3. Middle Panel to be 1/4” rigid PVC 4"

1 / board Sintra in standard black. Front Elevation Permanently attached to Back 2 Scale : 3” = 1’ - 0” Panel.

4. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle 1/4" 1/8" Panel on all four sides. Provide vinyl backup plate to match V-5 Silver for glass-mount conditions.

5. Provide vinyl backup plate to

4" match V-5 Silver for glass-mount 1 / 1 conditions. 4"

2 1 / 6. Raised text painted to match P-2 White. Grade 2 Braille left unpainted. Font: Helvetica LT Std Roman. 2 7. Laser engraved text. Font: Helvetica LT Std Bold.

8. Complete assembly to be mounted with low-VOC thin-mil

7 5/8" VHB Tape and low-VOC silicone adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from strike side of door. /8" 4 7 3

4 4" 1 /

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.60B INTERIOR SIGNS Section 6

2930

CENTRAL STERILE PROCESSING DECONTAMINATION

INT.09 Typical Room Identity 1 Scale : Half-Sized

INT.09. 3 Typical Room Identity, Large - Wall Mounted A wall-mounted sign with raised copy and braille. Used to identify permanent rooms with fixed messages.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.60C INTERIOR SIGNS Section 6

INT.09.3 10 1/2" Typical Room Identity, Large - Wall Mounted 1/4" 10" 1/4"

4" 1. Room Number Panel to be .059” 1 / interior photopolymer painted to match P-1 Black. Permanently attached to Middle Panel. 4"

2 1 / 1 2. Text Panel to be .052” Rowmark Lasermark engraving material to 2 match 922-402 Black / White. Permanently attached to Middle Panel. 7 5/8" /8"

7 Rowmark, LLC 4 2040 Industrial Drive 3 Findlay, Ohio 45840 419.425.8974 4 www.rowmark.com

3. Middle Panel to be 1/4” rigid PVC 4"

1 / board Sintra in standard black. Front Elevation Permanently attached to Back 2 Scale : 3” = 1’ - 0” Panel.

4. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle 1/4" 1/8" Panel on all four sides.

5. Raised text painted to match P-2 White. Grade 2 Braille left unpainted. Font: Helvetica LT Std

4" Roman. 1 /

1 6. Laser engraved text. Font: Helvetica LT Std Bold. 4" 2 1 / 7. Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from 2 strike side of door. 7 5/8" /8" 4 7 3

4 4" 1 /

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.60D INTERIOR SIGNS Section 6

2254

ANESTHESIA FACULTY OFFICE

Name Insert

INT.10 Changeable Room Identity 1 Scale : Half-Sized

INT.10.1 Changeable Room Identity - Wall Mounted

change. A permanent message shall display permanent generic room title (i.e. .) The Owner shall provide an insert with the appropriate message, based on the layout shown in the following pages.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.61 INTERIOR SIGNS Section 6

INT.10.1 9" Changeable Room Identity - Wall Mounted 1/4" 8 1/2" 1/4"

4" 1. Room Number Panel to be .059” 1 / interior photopolymer painted to match P-1 Black. Permanently attached to Middle Panel. 4"

2 1 / 1 2. Text Panel to be .052” Rowmark Lasermark engraving material to 2 match 922-402 Black / White. Permanently attached to Middle

4" Panel. 7 5/8" 3 1 / Rowmark, LLC 3 2040 Industrial Drive Findlay, Ohio 45840 4 419.425.8974 1 5/8" www.rowmark.com

3. Aluminum “C” channel as 4"

1 / 5 provided by The JRS Company Front Elevation (Part No. 29) in satin silver finish. 2 Scale : 3” = 1’ - 0” Permanently attached to Middle Panel.

The JRS Company 544 North Rimsdale Avenue Box 2035 Covina, CA 91722 626.967.2432 1/4" 1/8" 626.966.0714 Fax www.jrscoinc.com

4. Message Insert to be .052” Rowmark Lasermark engraving 4"

1 / material to match 922-402 Black 1 / White. Adhere into “C” channel with film tape. 4"

2 1 / 5. Middle Panel to be 1/4” rigid PVC board Sintra in standard black. Permanently attached to Back Panel. 2 6. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle Panel on all four sides. 7 5/8" 4" 7. Raised text painted to match

3 1 / 6 P-2 White. Grade 2 Braille left unpainted. Font: Helvetica LT Std Roman.

8. Laser engraved text. Font: Helvetica LT Std Bold. 3 9. Complete assembly to be mounted with low-VOC thin-mil 4 VHB Tape and low-VOC silicone 1 1/2" 1 5/8" adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from 5 strike side of door. 4" 1 /

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.62 INTERIOR SIGNS Section 6

2254

ANESTHESIA FACULTY OFFICE

Name Insert

INT.10 Changeable Room Identity 1 Scale : Half-Sized

INT.10.2 Changeable Room Identity - Glass Mounted A glass-mounted sign used to identify an office or room whose occupant or function is subject to frequent change. A permanent message shall display permanent generic room title (i.e. Office 1, Room 1, etc.). The Owner shall provide an insert with the appropriate message, based on the layout shown in the following pages.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.62A INTERIOR SIGNS Section 6

INT.10.2 9" Changeable Room Identity - Glass Mounted 1/4" 8 1/2" 1/4"

4" 1. Room Number Panel to be .059” 1 / interior photopolymer painted to match P-1 Black. Permanently attached to Middle Panel. 4"

2 1 / 1 2. Text Panel to be .052” Rowmark Lasermark engraving material to 2 match 922-402 Black / White. Permanently attached to Middle

4" Panel. 7 5/8" 3 1 / Rowmark, LLC 3 2040 Industrial Drive Findlay, Ohio 45840 4 419.425.8974 1 5/8" www.rowmark.com

3. Aluminum “C” channel as 4"

1 / 5 provided by The JRS Company Front Elevation (Part No. 29) in satin silver finish. 2 Scale : 3” = 1’ - 0” Permanently attached to Middle Panel.

The JRS Company 544 North Rimsdale Avenue Box 2035 Covina, CA 91722 626.967.2432 1/4" 1/8" 626.966.0714 Fax www.jrscoinc.com

4. Message Insert to be .052” Rowmark Lasermark engraving 4" /

1 material to match 922-402 Black 1 / White. Adhere into “C” channel with film tape. 4" /

2 1 5. Middle Panel to be 1/4” rigid PVC board Sintra in standard black. Permanently attached to Back Panel. 2 6. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle Panel on all four sides. 7 5/8" 4"

/ 7. Provide vinyl backup plate to

3 1 6 match V-5 Silver for glass-mounted conditions.

8. Raised text painted to match P-2 White. Grade 2 Braille left 3 unpainted. Font: Helvetica LT Std Roman.

4 9. Laser engraved text. Font: 1 1/2" 1 5/8" Helvetica LT Std Bold. 5 10. Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone 4" / 1 adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from strike side of door. Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.62B INTERIOR SIGNS Section 6

INT.10 1/2" 7 1/2" max message length 1/2" Changeable Room Identity

1 . Room Number Panel to be 059”. interior photopolymer painted 1 1/4"

5/8" ROOM NUMBER TEXT 7 to match P-1 Black . Permanently

5/8" attached to Middle Panel .

2 . Text Panel to be 052”. Rowmark Room Number Panel Lasermark engraving material to match 922-402 Black / White . 4 Scale : 3” = 1’ - 0” Permanently attached to Middle Panel .

Rowmark, LLC 2040 Industrial Drive 1/2" 7 1/2" max message length 1/2" Findlay, Ohio 45840 419 .425 .8974 www .rowmark com. 1" Room Name Text 8 3 . Aluminum “C” channel as provided by The JRS Company 7/8" 1/2" Room Name Text (Part No . 29) in satin silver finish .

7/8" Room Name Text Permanently attached to Middle Panel .

The JRS Company Text Panel 544 North Rimsdale Avenue 5 Scale : 3” = 1’ - 0” Box 2035 Covina, CA 91722 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com. 8 1/2" 4 . Message Insert to be 052”. Rowmark Lasermark engraving 1/2" 7 1/2" max message length 1/2" material to match 922-402 Black / White . Adhere into “C” channel with film tape . EQ Insert Text 3/8"

1 1/2" 8 5 . Middle Panel to be 1/4” rigid PVC EQ board Sintra in standard black . Permanently attached to Back 3/8" Panel .

5/8" Insert Text 8 6 . Back Panel to be 1/8” rigid PVC 1 1/2"

5/8" Insert Text board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide Message Insert vinyl backup plate to match V-5 6 Scale : 3” = 1’ - 0” Silver for glass-mount conditions .

7 . Raised text painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman .

8 . Laser engraved text . Font: Helvetica LT Std Bold .

9 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side of door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.63 INTERIOR SIGNS Section 6

2211

CONSULTATION ROOM

In Use

INT.11 Typical Room Identity With “In Use” 1 Scale : Half-Sized

2211

CONSULTATION ROOM

Open

Alternate Slider Position 2 Scale : 3” = 1’ - 0”

INT.11 Typical Room Identity With “In Use” A wall-mounted sign with raised copy and braille and operable “In Use” indicator, used only to maintain privacy. Possible uses include Conference, Consult Rooms, or Exam Rooms. Given the additional expense, the use of this sign should be limited.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.64 INTERIOR SIGNS Section 6

INT.11 9" Typical Room Identity With “In Use” 1/4" 8 1/2" 1/4" 1 . Room Number Panel to be 059”. 1/4" interior photopolymer painted to match P-1 Black . Permanently attached to Middle Panel .

2 1/4" 1 2 . Text Panel to be 052”. Rowmark Lasermark engraving material to match 922-402 Black / White . 2 Permanently attached to Middle Panel . 7 5/8"

3 1/4" 7 Rowmark, LLC 2040 Industrial Drive 3 Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

1 5/8" 4 3 . Aluminum “C” channel as provided 5 by The JRS Company (Part No . 29) in satin silver finish . Permanently 1/4" 6 attached to Middle Panel . The JRS Company 1/4" 4" 4" 1/4" 544 North Rimsdale Avenue Front Elevation Box 2035 Covina, CA 91722 3 Scale : 3” = 1’ - 0” 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com.

4 . Acrylic channel stop to hold in 1/4" 1/8" slider, painted to match P-1 Black .

5 . Acrylic slider in “C” channel . Painted to match P-1 Black .

6 . Applied “Open” field (left half 1/4" of channel) to match V-6 Green . 1 Applied “In Use” field (right half of channel) to match V-3 Red . Entire inside of channel is coated with 2 1/4" clear matte vinyl overlay .

7 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back 2 Panel . 8 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on

7 5/8" all four sides . Provide vinyl backup plate to match V-5 Silver for glass- 3 1/4" 8 mount conditions .

9 . Raised text painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman . 3 10 . Laser engraved text . Font: Helvetica LT Std Bold . 4 1 1/2" 1 5/8" 11 . Applied vinyl text to match V-2 White, under clear matte vinyl overlay . Font: Helvetica LT Std Bold . 7 12 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape 1/4" and low-VOC silicone adhesive . Side Elevation Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side 4 Scale : Half-Sized of door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.65 INTERIOR SIGNS Section 6

INT.11 1/2" 7 1/2" max message length 1/2" Typical Room Identity With “In Use”

1 . Room Number Panel to be 059”. 1 1/4"

5/8" ROOM NUMBER TEXT 9 interior photopolymer painted to match P-1 Black . Permanently 5/8" attached to Middle Panel .

2 . Text Panel to be 052”. Rowmark Room Number Panel Lasermark engraving material to 5 Scale : 3” = 1’ - 0” match 922-402 Black / White . Permanently attached to Middle Panel .

Rowmark, LLC 2040 Industrial Drive 1/2" 7 1/2" max message length 1/2" Findlay, Ohio 45840 419 .425 .8974 www .rowmark com. 1" Room Name Text 10 3 . Aluminum “C” channel as provided by The JRS Company (Part No . 29) 7/8" 1/2" Room Name Text in satin silver finish . Permanently attached to Middle Panel . 7/8" Room Name Text The JRS Company 544 North Rimsdale Avenue Box 2035 Text Panel Covina, CA 91722 6 Scale : 3” = 1’ - 0” 626 .967 .2432 626 .966 0714. Fax www .jrscoinc com.

4 . Acrylic channel stop to hold in slider, painted to match P-1 Black .

5 . Acrylic slider in “C” channel . 2 1/4" 2 1/4" Painted to match P-1 Black .

6 . Applied “Open” field (left half of channel) to match V-6 Green . 1" Applied “In Use” field (right half of 1/2" Open In Use 11 channel) to match V-3 Red . Entire inside of channel is coated with clear matte vinyl overlay . “In Use” Message 7 7 . Middle Panel to be 1/4” rigid PVC Scale : 3” = 1’ - 0” board Sintra in standard black . Permanently attached to Back Panel .

8 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass- mount conditions .

9 . Raised text painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman .

10 . Laser engraved text . Font: Helvetica LT Std Bold .

11 . Applied vinyl text to match V-2 White, under clear matte vinyl overlay . Font: Helvetica LT Std Bold .

12 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side of door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.66 INTERIOR SIGNS Section 6

RESTROOMS

STAFF RESTROOM

INT.13.1 Restroom Identity Alternate Layout 1 Scale : Half-Sized 2 Scale : 3” = 1’ - 0”

INT.13.1 Restroom Identity A wall-mounted sign with raised copy and braille, used to identify restrooms. This sign must be located on the wall adjacent to the strike side of the door. Door-mounted installation is not acceptable at any location. Provide an accompanying overhead destination sign, sign type INT.03.2.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.67 INTERIOR SIGNS Section 6

INT.13.1 Restroom Identity 7" 1. Message Panel to be .059” 1/4" 6 1/2" 1/4" interior photopolymer painted to match P-1 Black. Permanently attached to Middle Panel. 4"

1 / 2. Middle Panel to be 1/4” rigid PVC 1 board Sintra in standard black. Permanently attached to Back Panel.

3. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle 2 Panel on all four sides. 11"

10 1/2" 4. Raised text and symbol painted to match P-2 White. Grade 2 Braille left unpainted. Font: 3 Helvetica LT Std Roman. 5. Raised text painted to match P-2 White. Grade 2 Braille left unpainted. Font: Helvetica LT Std Bold. 4" 1 / 6. Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone Front Elevation adhesive. Sign to be located at 3 Scale : 3” = 1’ - 0” 5’- 0” to center A.F.F. and 3” from strike side of door.

1/4" 1/8" 4" 1 / 1

2

3 11" 10 1/2" 4" 1 /

Side Elevation 4 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.68 INTERIOR SIGNS Section 6

INT.13 6 1/2" Restroom Identity

1/2" 5 1/2" max message length 1/2" 1 . Message Panel to be 059”. interior photopolymer painted to match P-1 Black . Permanently attached to Middle Panel . 1 1/4"

5/8" ROOM NUMBER TEXT 4 2 . Middle Panel to be 1/4” rigid PVC

5/8" board Sintra in standard black . Permanently attached to Back Panel . 4 3 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . 4 3/4" 4" 4 . Raised text and symbol painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman .

1 7/8" 5 . Raised text painted to match

5/8" RESTROOM TEXT 5 P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std 1" RESTROOM TEXT Bold . 5/8" 6 . Complete assembly to be mounted with low-VOC thin-mil Message Panel VHB Tape and low-VOC silicone adhesive . Sign to be located at 5 Scale : 3” = 1’ - 0” 5’- 0” to center A .F .F . and 3” from strike side of door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.69 INTERIOR SIGNS Section 6

2934

2872

WOMEN’S

LOCKER STAFF ROOM RESTROOM

INT.13.2 Restroom Identity Alternate Layout 1 Scale : Half-Sized 2 Scale : 3” = 1’ - 0”

INT.13.2 Restroom Identity A wall-mounted sign with raised copy and braille, used to identify restrooms. This sign must be located on the wall adjacent to the strike side of the door. Door-mounted installation is not acceptable at any location. Provide an accompanying overhead destination sign, sign type INT.03.2.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.69A INTERIOR SIGNS Section 6

INT.13.2 Restroom Identity 7" 1. Message Panel to be .059” 1/4" 6 1/2" 1/4" interior photopolymer painted to match P-1 Black. Permanently attached to Middle Panel. 4"

1 / 2. Middle Panel to be 1/4” rigid PVC 1 board Sintra in standard black. Permanently attached to Back Panel.

3. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle 2 Panel on all four sides. 1'-0" 11 1/2" 4. Raised text and symbol painted to match P-2 White. Grade 2 Braille left unpainted. Font: 3 Helvetica LT Std Roman. 5. Raised text painted to match P-2 White. Grade 2 Braille left unpainted. Font: Helvetica LT Std Bold.

6. Complete assembly to be 4"

1 / mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from Front Elevation strike side of door. 3 Scale : 3” = 1’ - 0”

1/4" 1/8" 4" 1 / 1

2

3 1'-0" 11 1/2" 4" 1 /

Side Elevation 4 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.69B INTERIOR SIGNS Section 6

INT.13 6 1/2" Restroom Identity

1/2" 5 1/2" max message length 1/2" 1 . Message Panel to be 059”. interior photopolymer painted to match P-1 Black . Permanently attached to Middle Panel . 1 1/4" 5/8" 2 . Middle Panel to be 1/4” rigid PVC

5/8" board Sintra in standard black . Permanently attached to Back Panel . 4 3 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . 4 3/4" 4" 4 . Raised text and symbol painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman .

1 7/8" 5 . Raised text painted to match

5/8" RESTROOM TEXT 5 P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std 1" RESTROOM TEXT Bold . 5/8" 6 . Complete assembly to be mounted with low-VOC thin-mil Message Panel VHB Tape and low-VOC silicone adhesive . Sign to be located at 5 Scale : 3” = 1’ - 0” 5’- 0” to center A .F .F . and 3” from strike side of door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.69 INTERIOR SIGNS Section 6

Name Insert

Admitting/ Patient Registration

INT.14 Workstation Identity 1 Scale : Half-Sized

INT.14 Workstation Identity A wall-mounted sign used to identify an cubicle or desk whose occupant or function is subject to frequent change . The Owner shall provide an insert with the appropriate message, based on the layout shown in the following pages .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.70 INTERIOR SIGNS Section 6

INT.14 8 1/2" Workstation Identity 1 . Aluminum “C” channel as 1/4" 8" 1/4" provided by The JRS Company (Part No . 29) in satin silver finish . 1/4" Permanently attached to Back 1 Panel . The JRS Company 544 North Rimsdale Avenue 2 1/8" 1 5/8" 2 Box 2035 Covina, CA 91722 626 .967 .2432 626 .966 0714. Fax 3 www .jrscoinc com. 1/4" Front Elevation 2 . Message Insert to be 052”. 2 Scale : Half-Sized Rowmark Lasermark engraving material to match 922-402 Black / White . Adhere into “C” channel with film tape .

1/4" Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974

1/4" 5 www .rowmark com.

1 3 . Back Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back 2 2 1/8" 1 5/8" Panel . 1 1/2"

4 . Laser engraved text . Font: 3 Helvetica LT Std Bold .

1/4" 5 . Mounting hardware and location determined by individual Side Elevation mounting conditions . 3 Scale : Half-Sized 6. Signage Contractor to price “worse case scenario” for each project, on a project-by-project basis, depending on selected workstations used at that 8" project. Possibel solutions could be: 1/2" 7" max message length 1/2" 1) Fabricated and painted 040. aluminum bracket, attached to back-plate, as needed

EQ 2) Specialized fabric tape tape or 3M “Dual Lock” 3/8" 1 1/2" Insert Text 4 EQ 5/8"

3/8" Insert Text 4 1 1/2" 5/8" Insert Text

Message Insert 4 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.71 INTERIOR SIGNS Section 6

Map Artwork Not In Graphic Designer’s Scope of Work.

Awarded Signage Contractor responsible for the creation of all map artwork, based on one “Go By” provided by Graphic Designer.

In Case Of Fire, Do Not Use Elevators. Use Designated Fire Exits.

INT.16.1 Elevator Call Button Map 1 Scale : 3” = 1’ - 0”

INT.16.1 Elevator Call Button Map A wall-mounted sign posted immediately above public elevator call button which posts specific information required by governing Building or Fire Codes .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.72 INTERIOR SIGNS Section 6

11 1/2" INT.16.1 Elevator Call Button Map

1/4" 11" 1/4" 1 . Message Panel to be 052”.

1/4" Rowmark Lasermark engraving material to match 922-402 Black / White . Permanently attached to Middle Panel .

Rowmark, LLC 2040 Industrial Drive 1 Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

2 2 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel . 3 3 . Back Panel to be 1/8” rigid PVC 1'-3"

1'-2 1/2" 1'-2 board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

4 . Laser engraved text and map artwork . Font: Helvetica LT Std Roman .

5 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone 1/4" adhesive . Sign to be centered 3” above elevator call button panel . Front Elevation 2 Scale : 3” = 1’ - 0”

1/4" 1/8" 1/4" 1

2 1'-3" 1'-2 1/2" 1'-2

3 1/4"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.73 INTERIOR SIGNS Section 6

INT.16.1 1/2" 10" max message length 1/2" Elevator Call Button Map 1 . Message Panel to be 052”. Rowmark Lasermark engraving material to match 922-402 Black / White . Permanently attached to 1/2" Middle Panel .

Rowmark, LLC 4 2040 Industrial Drive Findlay, Ohio 45840 Map Artwork 419 .425 .8974 Not In Graphic Designer’s www .rowmark com. Scope of Work.

10" Awarded Signage Contractor 2 . Middle Panel to be 1/4” rigid PVC responsible for the creation of all map artwork, board Sintra in standard black . based on one “Go By” provided Permanently attached to Back by Graphic Designer. Panel .

3 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

1 1/4" Single Message Text 4 . Laser engraved text and map artwork . Font: Helvetica LT Std 7/8" 1/2" Single Message Text Roman .

1 1/4" Multiple Message Text 5 . Complete assembly to be mounted with low-VOC thin-mil

1/2" VHB Tape and low-VOC silicone Message Panel adhesive . Sign to be centered 3” above elevator call button panel . 4 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.74 INTERIOR SIGNS Section 6

STAFF ONLY

Map Artwork Not In Graphic Designer’s Scope of Work.

Awarded Signage Contractor responsible for the creation of all map artwork, based on one “Go By” provided by Graphic Designer.

In Case Of Fire, Do Not Use Elevators. Use Designated Fire Exits.

INT.16.2 Elevator Call Button Map, Staff 1 Scale : 3” = 1’ - 0”

INT.16.2 Elevator Call Button Map, Staff A wall-mounted sign posted immediately above staff elevator call button which posts specific information required by governing Building or Fire Codes .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.75 INTERIOR SIGNS Section 6

11 1/2" INT.16.2 Elevator Call Button Map, 1/4" 11" 1/4" Staff 1/4" 1 . Staff Panel to be 052”. Rowmark Lasermark engraving material to match 922-602 Red / White . 1 Permanently attached to Middle 2 1/4" Panel .

Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974 2 www .rowmark com. 2 . Message Panel to be 052”. Rowmark Lasermark engraving material to match 922-402 Black 3 / White . Permanently attached to Middle Panel .

3 . Middle Panel to be 1/4” rigid PVC 1'-5 1/4" 4 board Sintra in standard black . Permanently attached to Back 1'-2 1/2" 1'-2 Panel .

4 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

5 . Laser engraved text . Font: Helvetica LT Std Bold .

6 . Laser engraved text and map . 1/4" Font: Helvetica LT Std Roman .

Front Elevation 7 . Complete assembly to be 2 Scale : 3” = 1’ - 0” mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be centered 3” 1/4" 1/8" above elevator call button panel . 1/4" 1 2 1/4" 3

2 1'-5 1/4" 1'-2 1/2" 1'-2

4 1/4"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.76 INTERIOR SIGNS Section 6

INT.16.2 Elevator Call Button Map, 1/2" 10" max message length 1/2" Staff

1 . Staff Panel to be 052”. Rowmark Lasermark engraving material 1 1/8" to match 922-602 Red / White . 5/8" “STAFF ONLY” TEXT 5 Permanently attached to Middle 1 1/8" Panel .

Staff Panel Rowmark, LLC 2040 Industrial Drive 4 Scale : 3” = 1’ - 0” Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

2 . Message Panel to be 052”. Rowmark Lasermark engraving material to match 922-402 Black 1/2" 10" max message length 1/2" / White . Permanently attached to Middle Panel .

3 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . 1/2" Permanently attached to Back Panel .

6 4 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Map Artwork Inset 1/2” from edge of Middle Not In Graphic Designer’s Panel on all four sides . Provide Scope of Work. vinyl backup plate to match V-5 Silver for glass-mount conditions . 10" Awarded Signage Contractor responsible for the creation of all map artwork, based on one “Go By” provided 5 . Laser engraved text . Font: by Graphic Designer. Helvetica LT Std Bold .

6 . Laser engraved text and map . Font: Helvetica LT Std Roman .

7 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be centered 3” 1 1/4" Single Message Text above elevator call button panel . 7/8" 1/2" Single Message Text

1 1/4" Multiple Message Text 1/2"

Message Panel 5 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.77 INTERIOR SIGNS Section 6

STAIR G NO RE-ENTRY

INT.17 Stair Corridor Identity 1 Scale : 3” = 1’-0”

INT.17 Stair Corridor Identity A wall-mounted sign with raised copy and braille, used to label stair designation (Stair A, Exit Stair B, etc.) Specific messages are governed by County Fire Codes.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.78 INTERIOR SIGNS Section 6

INT.17 Stair Corridor Identity 1'-0" 1. Message Panel to be .059” 1/4" 11 1/2" 1/4" interior photopolymer painted to match P-1 Black. Permanently 1/4" attached to Middle Panel.

2. Middle Panel to be 1/4” rigid PVC board Sintra in standard black. 1 Permanently attached to Back Panel.

1'-0" 3. Back Panel to be 1/8” rigid PVC 2 board Sintra in standard black. 11 1/2" Inset 1/2” from edge of Middle Panel on all four sides. Provide 3 vinyl backup plate to match V-5 Silver for glass-mount conditions.

1/4" 4. Raised text painted to match P-2 White. Grade 2 Braille left Front Elevation unpainted. Font: Helvetica LT Std 2 Scale : 1 1/2” = 1’ - 0” Bold. 5. Raised text painted to match P-2 White. Grade 2 Braille left unpainted. Font: Helvetica LT Std Roman.

6. Complete assembly to be mounted with low-VOC thin-mil 1/4" 1/8" VHB Tape and low-VOC silicone adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from strike side of door. 1/4" 1 1'-0" 11 1/2" 2

3 1/4"

Side Elevation 3 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.79 INTERIOR SIGNS Section 6

INT.17 1/2" 7 1/2" max message length 1/2" Stair Corridor Identity 1 . Message Panel to be 059”. interior photopolymer painted to match P-1 Black . Permanently

1 7/8" attached to Middle Panel . 1" STAIR IDENTIFICATION TEXT 4 2 . Middle Panel to be 1/4” rigid PVC

1 1/2" STAIR IDENTIFICATION TEXT board Sintra in standard black . Permanently attached to Back

5/8" Panel .

1" SECONDARY TEXT 5/8" 5 3 . Back Panel to be 1/8” rigid PVC board Sintra in standard black .

1 1/8" SECONDARY TEXT Inset 1/2” from edge of Middle Panel on all four sides . Provide

5/8" vinyl backup plate to match V-5 Silver for glass-mount conditions . Message Panel 4 . Raised text painted to match 4 Scale : 3” = 1’ - 0” P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Bold .

5 . Raised text painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman .

6 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side of door .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.80 INTERIOR SIGNS Section 6

STAIR A stair a ROOF ACCESS LOCKED

5#3 1 THROUGH 5 NO RE-ENTRY RE-ENTRY ON 1 EXIT 1ST FLOOR

INT.18 Stairwell Identity 1 Scale : 3” = 1’ - 0”

INT.18 Stairwell Identity A wall-mounted sign with raised copy and braille, located in the stairwell, to designate stair level and re-entry information. Specific messages are governed by County Fire Codes. Locate on wall to insure visibility when door is opened or closed.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.81 INTERIOR SIGNS Section 6

INT.18 1'-4" Stairwell Identity

1/4" 1'-3 1/2" 1/4" 1. Message Panel to be .059” interior photopolymer painted 1/4" to match P-1 Black. Permanently attached to Middle Panel.

2. Middle Panel to be 1/4” rigid PVC board Sintra in standard black. 1 Permanently attached to Back Panel.

3. Back Panel to be 1/8” rigid PVC 2 board Sintra in standard black. Inset 1/2” from edge of Middle Panel on all four sides. Provide 3 vinyl backup plate to match V-5 Silver for glass-mount conditions.

4. Raised text painted to match P-2 White. Grade 2 Braille left 1'-4"

1'-3 1/2" 1'-3 unpainted. Font: Helvetica LT Std Bold.

5. Raised text and symbols painted to match P-2 White. Grade 2 Braille left unpainted. Font: Helvetica LT Std Roman.

6. Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive. Sign to be located at 5’- 0” to center A.F.F. and 3” from strike side of door.

Front Elevation 1/4" 2 Scale : 3” = 1’ - 0”

1/4" 1/8" 1/4" 1 1'-3 1/2" 1'-3 1'-4"

2

3 1/4"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.82 INTERIOR SIGNS Section 6

INT.18 Stairwell Identity 4 1/4" 4 1/4" 1 . Message Panel to be 059”. 7" 7" interior photopolymer painted to match P-1 Black . Permanently attached to Middle Panel . 1/2" 1'-1" max message length 1/2" 2 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel . 2"

1" 4 3 . Back Panel to be 1/8” rigid PVC STAIR LEVEL board Sintra in standard black . Inset 1/2” from edge of Middle STAIR LEVEL Panel on all four sides . Provide 2 1/2" 2" 4 IDENTIFICATION IDENTIFICATION vinyl backup plate to match V-5 Silver for glass-mount conditions .

5/8" 4 . Raised text painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std 1 7/8" 1" STAIR LEVEL ACCESS TEXT 5 Bold .

5/8" 5 . Raised text and symbols painted to match P-2 White . Grade 2 Braille left unpainted . Font: 1 5/8" 1" RE-ENTRY TEXT Helvetica LT Std Roman . 3/4" 6 . Complete assembly to be mounted with low-VOC thin-mil 1 1/2" 1" ROOF ACCESS TEXT VHB Tape and low-VOC silicone adhesive . Sign to be located at

3/4" 5’- 0” to center A .F .F . and 3” from strike side of door . 1 1/2" 1" EXIT LEVEL TEXT 3/4"

1/2"

Message Panel 4 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.83 INTERIOR SIGNS Section 6

WARNING STRONG MAGNETIC FIELD

NO NO NO LARGE NO SMALL PACEMAKERS CREDIT CARDS METAL OBJECTS METAL OBJECTS

CAUTION MAGNETIC FIELD MAY DAMAGE CAMERAS, MECHANICAL WATCHES, CREDIT CARDS, RECORDING MATERIALS AND OTHER MECHANICAL AND MAGNETIC SENSITIVE DEVICES.

INT.19.1 Notice Posting, Extra-Large 1 Scale : 3” = 1’ - 0”

Alternate Layout 2 Scale : 1 1/2” = 1’ - 0”

INT.19.1 Notice Posting, Extra-Large Door- or wall-mounted sign used to present specific warnings or information . Colors of sign and copy size are determined by OSHA or State Regulatory Requirements .

Use this sign only when the message will not fit on sign types INT 19. .2, INT 19. .3 or INT 19. .4 . Refer to page 4 .4 for Symbol Standards .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.84 INTERIOR SIGNS Section 6

1'-6" INT.19.1 Notice Posting, Extra-Large

1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Message Panel on all four sides . Provide 1 vinyl backup plate to match V-5 Silver for glass-mount conditions .

3 . Screen printed symbols to match 2 P-1 Black, P-2 White and P-3 Red .

4 . Screen printed text to match P-2 White and P-3 Red . Font: Helvetica LT Std Roman . 1'-6" 5 . Screen printed symbols to match P-1 Black, P-2 White, P-3 Red, P-4 Yellow or P-7 Blue .

6 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and centered in the middle of door .

Refer to Symbol Standards on page 4.4.

Front Elevation 3 Scale : 3” = 1’ - 0” 1/4" 1/8"

1 1'-6"

2

Side Elevation 4 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.85 INTERIOR SIGNS Section 6

INT.19.1 1" 1'-4" max message length 1" Notice Posting, Extra-Large

1 . Message Panel to be 1/4” rigid PVC board Sintra in standard WARNING black . Permanently attached to 3 1/2" STRONG MAGNETIC FIELD Back Panel .

2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Message 3 Panel on all four sides . Provide 8 1/2" vinyl backup plate to match V-5 Silver for glass-mount conditions .

3 . Screen printed symbols to match

1/2" P-1 Black, P-2 White and P-3 Red .

2 1/2" 4 . Screen printed text to match NO NO NO LARGE NO SMALL

3/4" PACEMAKERS CREDIT CARDS METAL OBJECTS METAL OBJECTS P-2 White and P-3 Red . Font:

CAUTION MAGNETIC FIELD MAY DAMAGE CAMERAS, MECHANICAL WATCHES, CREDIT CARDS, RECORDING

1 1/4" MATERIALS AND OTHER MECHANICAL AND MAGNETIC SENSITIVE DEVICES. Helvetica LT Std Roman . 1" 5 . Screen printed symbols to match Message Panel - Symbols P-1 Black, P-2 White, P-3 Red, P-4 Yellow or P-7 Blue . 5 Scale : 1 1/2” = 1’ - 0” 6 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located 1" 1'-4" max message length 1" at 5’- 0” to center A .F .F . and centered in the middle of door . 1 1/8" Refer to Symbol Standards on

2 1/8" WARNING 4 page 4.4. STRONG MAGNETIC FIELD 3/4" 9/16" 1/4" 3/8" NO NO NO LARGE NO SMALL 3/4" PACEMAKERS CREDIT CARDS METAL OBJECTS METAL OBJECTS

CAUTION MAGNETIC FIELD MAY DAMAGE CAMERAS, MECHANICAL WATCHES, CREDIT CARDS, RECORDING MATERIALS AND OTHER MECHANICAL AND MAGNETIC SENSITIVE DEVICES. 1" 1/4" 1/8" Message Panel - Text 6 Scale : 1 1/2” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.86 INTERIOR SIGNS Section 6

INT.19.1 1" 1'-4" max message length 1" Notice Posting, Extra-Large 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard 1" black . Permanently attached to Back Panel .

2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Message 5 Panel on all four sides . Provide vinyl backup plate to match V-5 Symbol Silver for glass-mount conditions . 1'-4"

3 . Screen printed symbols to match P-1 Black, P-2 White and P-3 Red .

4 . Screen printed text to match P-2 White and P-3 Red . Font: Helvetica LT Std Roman . 1" 5 . Screen printed symbols to match P-1 Black, P-2 White, P-3 Red, P-4 Message Panel - Symbols Yellow or P-7 Blue . 6 Scale : 1 1/2” = 1’ - 0” 6 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and centered in the middle of door .

Refer to Symbol Standards on page 4.4.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.87 INTERIOR SIGNS Section 6

WOMEN About to be x-rayed? If you are pregnant, or feel you might be pregnant, please inform the technologist so appropriate protective measures can be taken.

INT.19.2 Notice Posting, Large 1 Scale : 3” = 1’ - 0”

INT.19.2 Notice Posting, Large Door- or wall-mounted sign used to present specific warnings or information . Colors of sign and copy size are determined by OSHA or State Regulatory Requirements .

Use this sign only when the message will not fit on sign types INT 19. .3 or INT 19. .4 . Use this sign in lieu of sign type INT 19. 1. whenever possible . Refer to page 4 .4 for Symbol Standards .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.88 INTERIOR SIGNS Section 6

INT.19.2 1'-0" Notice Posting, Large

1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

2 . Back Panel to be 1/8” rigid PVC 1 board Sintra in standard black . Inset 1/2” from edge of Message Panel on all four sides . Provide 2 vinyl backup plate to match V-5 Silver for glass-mount conditions .

3 . Screen printed text to match P-2

1'-0" White . Font: Helvetica LT Std Roman .

4 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and centered in the middle of door .

Refer to Symbol Standards on page 4.4.

Front Elevation 2 Scale : 3” = 1’ - 0”

1/4" 1/8"

1 1'-0"

2

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.89 INTERIOR SIGNS Section 6

INT.19.2 1/2" 11" max message length 1/2" Notice Posting, Large 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black .

6" Inset 1/2” from edge of Message Message Text Panel on all four sides . Provide 5/8" 3 vinyl backup plate to match V-5 1" Message Text Silver for glass-mount conditions . 3 . Screen printed text to match P-2

1 5/8" White . Font: Helvetica LT Std Message Text 5/8" Roman . 1" Message Text 4 . Complete assembly to be

1" mounted with low-VOC thin-mil Message Text VHB Tape and low-VOC silicone

6" adhesive . Sign to be located at 5’- 0” to center A .F .F . and centered in the middle of door .

Refer to Symbol Standards on page 4.4.

Message Panel 4 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.90 INTERIOR SIGNS Section 6

CAPACITY 186 PERSONS

Fire Marshall -- City Of Houston

BIOHAZARD

AUTHORIZED AUTHORIZED PERSONNEL PERSONNEL Beyond These Doors

INT.19.3 Notice Posting, Medium 1 Scale : 3” = 1’ - 0” CAUTION RADIATION

STAFF ONLY Beyond These Doors

Alternate Layouts 2 Scale : 1 1/2” = 1’ - 0” INT.19.3 Notice Posting, Medium Door- or wall-mounted sign used to present specific warnings or information. Colors of sign and copy size are determined by OSHA or State Regulatory Requirements.

Use this sign only when the message will not fit on sign type INT.19.4. Use this sign in lieu of sign type INT.19.1 or INT.19.2 whenever possible. Refer to page 4.4 for Symbol Standards.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.91 INTERIOR SIGNS Section 6

INT.19.3 9" Notice Posting, Medium 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

1 2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Message 2 Panel on all four sides . Provide vinyl backup plate to match V-5

9" Silver for glass-mount conditions .

EXCEPT AS NOTED BELOW:

For Radiation messages, face screen printed to match P-4 Yellow .

For Biohazard messages, face screen printed to match P-5 Orange . Front Elevation 3 . For standard messages, text 3 Scale : 3” = 1’ - 0” screen printed to match P-2 White . Font: Helvetica LT Std Roman .

EXCEPT AS NOTED BELOW: 1/4" 1/8" For Radiation messages, symbol and letters to match P-6 Purple .

For Biohazard messages, symbol and letters to match P-1 Black .

1 For Do Not Enter symbol, white border screen printed to match P-2 White . Red field screen printed to match P-3 Red, with reversed-out bar .

4 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located 9" at 5’- 0” to center A .F .F . and centered in the middle of door .

Refer to Symbol Standards on page 4.4.

2

Side Elevation 4 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.92 INTERIOR SIGNS Section 6

INT.19.3 Notice Posting, Medium 1/2" 8" max message length 1/2" 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel . 1 7/8"

2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Message 3 Panel on all four sides . Provide

4" Symbol vinyl backup plate to match V-5 Silver for glass-mount conditions .

EXCEPT AS NOTED BELOW:

For Radiation messages, face 1 1/4"

3/4" MESSAGE TEXT screen printed to match P-4 Yellow .

1 7/8" For Biohazard messages, face screen printed to match P-5 Orange .

3 . For standard messages, text screen printed to match P-2 White . Font: Helvetica LT Std

1 1/4" Roman .

EXCEPT AS NOTED BELOW:

For Radiation messages, symbol

4" Symbol 3 and letters to match P-6 Purple .

For Biohazard messages, symbol and letters to match P-1 Black .

For Do Not Enter symbol, white 1 1/4"

3/4" PRIMARY MESSAGE TEXT border screen printed to match P-2 White . Red field screen

1 1/4" printed to match P-3 Red, with

3/4" PRIMARY MESSAGE TEXT reversed-out bar . 1 1/4" 4 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and centered in the middle of door .

1 3/8" Refer to Symbol Standards on page 4.4.

4" Symbol 3 1 1/4"

3/4" PRIMARY MESSAGE TEXT

1" Secondary Message Text 1/2" 1 3/8"

Message Panel 5 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.93 INTERIOR SIGNS Section 6

FIRE EXIT STAFF ONLY

To enter between NON-FLAMMABLE 9 p.m. and 6 a.m. GAS IN USE enter code and press #

INT.19.4 Notice Posting, Small / Various Layouts Shown 1 Scale : 3” = 1’ - 0”

INT.19.4 Notice Posting, Small Door- or wall-mounted sign used to present specific warnings or information . Colors of sign and copy size are determined by OSHA or State Regulatory Requirements .

Use this sign in lieu of sign type INT 19. 1,. INT 19. .2 or INT 19. .3 whenever possible . Refer to page 4 4. for Symbol Standards .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.94 INTERIOR SIGNS Section 6

INT.19.4 Notice Posting, Small

8" 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

1 2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . 4" Inset 1/2” from edge of Message Panel on all four sides . Provide 2 vinyl backup plate to match V-5 Silver for glass-mount conditions .

3 . Text screen printed to match P-2 Front Elevation White . Font: Helvetica LT Std 2 Scale : 3” = 1’ - 0” Roman .

4 . Screen printed symbols to match P-1 Black, P-2 White, P-3 Red, P-4 Yellow or P-7 Blue . 1/4" 1/8" 5 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and centered in the middle of door .

Refer to Symbol Standards on 1 page 4.4. 4"

2

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.95 INTERIOR SIGNS Section 6

INT.19.4 Notice Posting, Small 1/2" 7" max message length 1/2" 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel . 2"

3/4" MESSAGE TEXT 3 2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . 1 1/4" MESSAGE TEXT Inset 1/2” from edge of Message 2" Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

3 . Text screen printed to match P-2

5/8" White . Font: Helvetica LT Std Roman . Symbol 1 1/2" 4 4 . Screen printed symbols to match P-1 Black, P-2 White, P-3 Red, P-4

1 1/4" Yellow or P-7 Blue .

3/4" MESSAGE TEXT

5/8" 5 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and centered in the middle of door . 2"

1/2" MESSAGE TEXT Refer to Symbol Standards on

7/8" MESSAGE TEXT page 4.4. 2"

Message Panel 4 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.96 INTERIOR SIGNS Section 6

STAFF ONLY Beyond These Doors

INT.19.5 Notice Posting, Glass Door Vinyl 1 Scale : Half Size

STAFF ONLY Beyond These Doors 5'-0" A.F.F. MAX 4'-0" A.F.F. MIN

INT.19.5 Notice Posting, Glass Door Vinyl 2 Scale : 1/4” = 1’ - 0”

INT.19.5 Notice Posting, Glass Door Vinyl Glass door-mounted sign used to present specific warnings or inform.ation Colors of sign and copy size are determined by OSHA or State Regulatory Requirements.

Use this sign in lieu of sign type INT.19.1, INT.19.2 or INT.19.3 whenever possible. Refer to page 4.4 for Symbol Standards.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.96A INTERIOR SIGNS Section 6

INT.19.5 Notice Posting, Glass Door Vinyl

1. Vinyl decal applied to first surface of glass. Symbol to match V-2 White and V-3 Red. Vinyl to be exterior grade. Font: Helvetica LT STD Bold.

Field verify glass conditions prior to fabrication. 4" " 16

/ Refer to Symbol Standards on 7 page 4.4. " 4 / 3 " 32 /

15 STAFF ONLY " 2 / 1 Beyond These Doors

INT.19.5 Notice Posting, Glass Door Vinyl 1 Scale : Half Size

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.96B INTERIOR SIGNS Section 6

10

INT.20 Overhead Cubicle Identity 1 Scale : 3/4” = 1’ - 0”

INT.20.1 Overhead Cubicle Identity A suspended ceiling-mounted sign with high visibility, used to identify cubicles . Primarily used in Emergency, Recovery and Holding Areas . When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers . Maintain 84” clearance or greater at all locations . Use only where visibility is not compromised .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.97 INTERIOR SIGNS Section 6

10" INT.20.1 Overhead Cubicle Identity

1 3/4" 1 3/4" 1 . B&N Rod system Ceiling Fixing part R12 .2/963230 in black anodized finish . Provide ceiling blocking as necessary . 6 B&N Industries 1409 Chapin Avenue, 2nd Floor 1 Burlingame, California 94010 650 .593 .4127 650 .593 .3112 (Fax) 2 www .bnind com.

2 . B&N Rod system 1/2” Rod varies by location by varies part R12 1. .5/963602 or 4/Page 6.113 R12 1. 10/963208. in black anodized finish, mechanically fastened to inside of aluminum angle sub-frame . Adjust rod to hang sign to a minimum 3 clearance of 7’-0” AFF . 3 . Message Panel to be 1/8” rigid PVC board Sintra in standard black . Permanently attached to 8" 4 sub-frame in field .

4 . Sub-frame to be standard 1/8” clear anodized aluminum channel with mitred corners . Pre-drill holes to receive threaded stud from B&N rod . Inset 1/2” from edge of Message Panel on all sides .

Front Elevation 5 . Applied vinyl text to match V-2 7'-0" A.F.F. 2 Scale : 3” = 1’ - 0” White . Font: Helvetica LT Std Roman .

6 . Additional blocking as needed .

7 . Complete assembly to be 1/8" 1" 1/8" located with 7’- 0” minimum to bottom A.F.F. (per A.D.A.)

Verify location of existing 2 adjacent EXIT lights, overhead emergency devices or other 1/2" obstructions so as not to block visibility to sign. 3 2 3

3 7" 8"

4 4 3

Side Elevation Side Section 3 Scale : Half-Sized 4 Scale : Full Size

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.98 INTERIOR SIGNS Section 6

INT.20.1 Overhead Cubicle Identity

1/2" 9" max message length 1/2" 1 . B&N Rod system Ceiling Fixing part R12 .2/963230 in black anodized finish . Provide ceiling blocking as necessary .

B&N Industries 1409 Chapin Avenue, 2nd Floor Burlingame, California 94010 5 650 .593 .4127 650 .593 .3112 (Fax) 6 1/2" www .bnind com. 5" Message Text 2 . B&N Rod system 1/2” Rod part R12 1. .5/963602 or R12 1. 10/963208. in black anodized finish, mechanically fastened to inside of aluminum angle sub-frame . Adjust rod to hang sign to a minimum clearance of 7’-0” AFF . Front & Back Message Panel 3 . Message Panel to be 1/8” rigid 5 Scale : 3” = 1’ - 0” PVC board Sintra in standard black . Permanently attached to sub-frame in field .

4 . Sub-frame to be standard 1/8” clear anodized aluminum channel with mitred corners . Pre-drill holes to receive threaded stud from B&N rod . Inset 1/2” from edge of Message Panel on all sides .

5 . Applied vinyl text to match V-2 White . Font: Helvetica LT Std Roman .

6 . Additional blocking as needed .

7 . Complete assembly to be located with 7’- 0” minimum to bottom A.F.F. (per A.D.A.)

Verify location of existing adjacent EXIT lights, overhead emergency devices or other obstructions so as not to block visibility to sign.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.99 INTERIOR SIGNS Section 6

center over window

10

INT.20.2 Wall Cubicle Identity 1 Scale : 3/4” = 1’ - 0”

INT.20.2 Wall Cubicle Identity A wall-mounted sign with high visibility, used to identify cubicles or windows . Primarily used in Reception, Cashier or Clinic Areas .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.100 INTERIOR SIGNS Section 6

INT.20.2 Wall Cubicle Identity

3" 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel . 10 2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Message Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

3 . Applied vinyl text to match V-2 White . Font: Helvetica LT Std Roman .

4 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be centered over a window or located at 7'-0" 7’- 0” to bottom A .F .F . depending on conditions .

5 . Mounting hardware and location determined by individual mounting conditions .

6. Signage Contractor to price “worse case scenario” for each project, on a project-by-project basis, depending on selected workstations used at that project. Possibel solutions could be: 1) Fabricated and painted Alternate Mounting Elevation 040. aluminum bracket, 2 Scale : 3/4” = 1’ - 0” attached to back-plate, as needed 2) Specialized fabric tape tape or 3M “Dual Lock”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.101 INTERIOR SIGNS Section 6

INT.20.2 Wall Cubicle Identity 10" 1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

2 . Back Panel to be 1/8” rigid PVC 1 board Sintra in standard black . Inset 1/2” from edge of Message Panel on all four sides . Provide vinyl backup plate to match V-5 8" 2 Silver for glass-mount conditions . 3 . Applied vinyl text to match V-2 White . Font: Helvetica LT Std Roman .

4 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be centered Front Elevation over a window or located at 3 7’- 0” to bottom A .F .F . depending Scale : 3” = 1’ - 0” on conditions .

5 . Mounting hardware and location determined by individual 1/4" 1/8" mounting conditions .

6. Signage Contractor to price “worse case scenario” for each project, on a project-by-project basis, depending on selected workstations used at that project. Possibel solutions could be: 1) Fabricated and painted 040. aluminum bracket, 1 attached to back-plate, as needed 2) Specialized fabric tape tape or 3M “Dual Lock”

2 8"

Side Elevation 4 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.102 INTERIOR SIGNS Section 6

INT.20.2 1/2" 9" max message length 1/2" Wall Cubicle Identity

1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

2 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . 3 Inset 1/2” from edge of Message 6 1/2" Panel on all four sides . Provide 5" Message Text vinyl backup plate to match V-5 Silver for glass-mount conditions .

3 . Applied vinyl text to match V-2 White . Font: Helvetica LT Std Roman .

4 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone Front & Back Message Panel adhesive . Sign to be centered 5 Scale : 3” = 1’ - 0” over a window or located at 7’- 0” to bottom A .F .F . depending on conditions .

5 . Mounting hardware and location determined by individual mounting conditions .

6. Signage Contractor to price “worse case scenario” for each project, on a project-by-project basis, depending on selected workstations used at that project. Possibel solutions could be: 1) Fabricated and painted 040. aluminum bracket, attached to back-plate, as needed 2) Specialized fabric tape tape or 3M “Dual Lock”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.103 INTERIOR SIGNS Section 6

“PURSUANT TO SECTION 30.06, PENAL CODE (TRESPASS BY HOLDER OF LICENSE TO CARRY A CONCEALED HANDGUN) A PERSON LICENSED UNDER ARTICLE 4412(29ee), REVISED STATUTES (CONCEALED HANDGUN LAW), MAY NOT ENTER THIS PROPERTY WITH A CONCEALED HANDGUN” (-Article 4413(29ee), Revised Statutes has been codified at Chapter 411, Subchapter H, Government Code) “CONFORME A LA SECCIÓN 30.06 DEL CÓDIGO PENAL (TRESPASAR PORTANDO ARMAS DE FUEGO) PERSONAS CON LICENCIA BAJO AUTORIDAD DEL ARTICULO 4413(29ee), ORDENANZAS REVISADAS (LEY DE PORTAR ARMAS), NO DEBEN ENTRAR A ESTA PROPIENDAD PORTANDO UN ARMA DE FUEGO” (-Articulo 4413(29ee) Ordenanzas Revisadas han sido codificadas en Capitulo 411, Sub-Capitulo H, Código de Gobierno)

INT.21.1 Handgun Regulations, Glass 1 Scale : 1 1/2” = 1’ - 0”

INT.21.1 Handgun Regulations, Glass A glass-mounted notice sign located at major building entrances, used to post Concealed Handgun regulations . By law, this sign must be posted in order to enforce handgun rules .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.104 INTERIOR SIGNS Section 6

INT.21.1 Handgun Regulations, Glass 2'-10" max message length 1 . First surface applied exterior- grade vinyl copy . Color as described below . Font: Helvetica 1" 1" “PURSUANT TO SECTION 30.06, PENAL CODE 1 LT Std Roman . (TRESPASS BY HOLDER OF LICENSE TO CARRY A 1 5/8" CONCEALED HANDGUN) A PERSON LICENSED 2 . Sign located at facility entrances . UNDER ARTICLE 4412(29ee), REVISED STATUTES Mounting conditions will vary per (CONCEALED HANDGUN LAW), MAY NOT ENTER location . 1/2" THIS PROPERTY WITH A CONCEALED HANDGUN” (-Article 4413(29ee), Revised Statutes has been codified at Chapter 411, Subchapter H, Government Code) 7/8" Field verify glass conditions 1" 2 1/2" “CONFORME A LA SECCIÓN 30.06 DEL CÓDIGO prior to fabrication. 2'-1/4" PENAL (TRESPASAR PORTANDO ARMAS DE 1 5/8" FUEGO) PERSONAS CON LICENCIA BAJO AUTORIDAD DEL ARTICULO 4413(29ee), For clear glass locations: Vinyl text to match V-1 Black . ORDENANZAS REVISADAS (LEY DE PORTAR ARMAS), NO DEBEN ENTRAR A ESTA PROPIENDAD

1/2" For tinted glass locations: PORTANDO UN ARMA DE FUEGO” Vinyl text to match V-2 White . (-Articulo 4413(29ee) Ordenanzas Revisadas han sido codificadas en Capitulo 411, Sub-Capitulo H, Código de 7/8" Gobierno) 7/8"

Front Elevation 2 Scale : 1” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.105 INTERIOR SIGNS Section 6

HCHD IS A SMOKE-FREE ENVIRONMENT

INT.21.3 No Smoking Regulations, Glass 1 Scale : Half-Sized

INT.21.3 No Smoking Regulations, Glass A glass-mounted sign sign located at major building entrances, used to post tobacco regulations .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.106 INTERIOR SIGNS Section 6

INT.21.3 No Smoking Regulations, Glass

1 . Vinyl decal applied to first surface of glass . Symbol to match V-1 Black, V-2 White and V-3 Red .

2 . First surface applied exterior- grade vinyl copy . Color as described below . Font: Helvetica

3" 1 LT Std Bold . 3 . Sign located at facility entrances . Mounting conditions will vary per location .

Field verify glass conditions prior to fabrication. 1" 1/2" HCHD IS A 2 For clear glass locations: Vinyl text to match V-1 Black . 7/8" For tinted glass locations: SMOKE-FREE Vinyl text to match V-2 White . 7/8" ENVIRONMENT

Front Elevation 2 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.107 INTERIOR SIGNS Section 6

HCHD IS A SMOKE-FREE ENVIRONMENT

INT.21.4 No Smoking Regulations, Wall-Mounted 1 Scale : 3” = 1’ - 0”

INT.21.4 No Smoking Regulations, Wall-Mounted A wall-mounted sign located at major building entrances or places where the public congregates, used to post tobacco regulations .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.108 INTERIOR SIGNS Section 6

INT.21.4 No Smoking Regulations, 10" Wall-Mounted

1 . Message Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to

1" Back Panel . 1 2 . Symbol to match V-1 Black, V-2 White and V-3 Red .

3 . Text to match V-2 White . Font: Helvetica LT Std Bold . 6" 2 4 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Message Panel on all four sides . 1'-1/2" 5 . For signs located at facility entrances, mounting conditions

2" will vary per location .

3/4" HCHD IS A 3 For signs located inside facility, complete assembly to be 1 1/4" SMOKE-FREE mounted with low-VOC thin-mil VHB Tape and low-VOC silicone

1 1/4" adhesive . Sign to be located at ENVIRONMENT 5’- 0” to center A .F .F .

Front Elevation 2 Scale : 3” = 1’ - 0”

1/4" 1/8"

1 1'-1/2"

4

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.109 INTERIOR SIGNS Section 6

8.5” x 11” (Evac Map)

INT.22 Insert Holder with Evacuation Map, 8.5 x 11 1 Scale : Half-Sized

INT.22. 1 Insert Holder with Evacuation Map, 8.5” x 11” A wall-mounted sign to carry a printed 8 1/2” x 11” sheet. Possible functions will include posting of Meeting Schedules outside Conference Rooms, Hours of Operations and applications where changeable posting may be required.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.110 INTERIOR SIGNS Section 6

9" INT.22.1 Insert Holder with. Evacuation Map 1/4" 8 1/2" 1/4" 8.5 x 11 1. Standard .5” x .75” aluminum “C” 4"

1 / channel. Permanently attached to Middle Panel. 4"

3 / 1 2. Window to be 1/8” clear acrylic with routed finger pulls. Adhere 2 into aluminum channel to create pocket for paper insert provided by Owner.

3. Spacer Panel to be 1/8” rigid PVC board Sintra in standard black. R 1/2" Permanently attached to Back Panel. /8"

1'-0" 3 9 7 4. Middle Panel to be 1/4” rigid PVC 4 board Sintra in standard black. Permanently attached to Middle 5 Panel. 5. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle Panel on all four sides. Provide

4" 1 vinyl backup plate to match V-5 3 / Silver for glass-mount conditions. 4" 1 / Front Elevation 6. Complete assembly to be 2 mounted with low-VOC thin-mil Scale : 3” = 1’ - 0” VHB Tape and low-VOC silicone adhesive. Sign to be located at 5’- 0” to center A.F.F. 1/4" 1/2" 1/8" 1/8" 4" 1 /

1 4" 3 / 2 3 /8" 1'-0" 9 7 11 1/8"

4

5 4" 3 / 1 4" 1 / Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.111 INTERIOR SIGNS Section 6

3" 3" INT.22.1 Insert Holder with. Evacuation Map 8.5 x 11 1. Standard .5” x .75” aluminum “C” channel. Permanently attached to Middle Panel.

2. Window to be 1/8” clear acrylic with routed finger pulls. Adhere into aluminum channel to create pocket for paper insert provided CL by Owner. 3. Spacer Panel to be 1/8” rigid PVC board Sintra in standard black. Permanently attached to Back Panel.

4. Middle Panel to be 1/4” rigid PVC board Sintra in standard black. Permanently attached to Middle Panel. 5'-0" 5. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle Panel on all four sides. Provide vinyl backup plate to match V-5 Silver for glass-mount conditions.

6. Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone Mounting Elevation adhesive. Sign to be located at 5’- 0” to center A.F.F. 5 Scale : 1/2” = 1’ - 0”

CL 5'-0"

Mounting Elevation, Alternate 6 Scale : 1/2” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.112 INTERIOR SIGNS Section 6

8.5” x 11” Paper Insert

INT.22 Insert Holder, 8.5 x 11 1 Scale : Half-Sized

INT.22.2 Insert Holder, 8.5” x 11” A wall-mounted sign to carry a printed 8 1/2” x 11” sheet. Possible functions will include posting of Meeting Schedules outside Conference Rooms, Hours of Operations and applications where changeable posting may be required.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.112A INTERIOR SIGNS Section 6

9" INT.22.2 Insert Holder, 8.5 x 11 1/4" 8 1/2" 1/4" 1. Standard .5” x .75” aluminum “C” 4"

1 / channel. Permanently attached to Middle Panel. 4"

3 / 1 2. Window to be 1/8” clear acrylic with routed finger pulls. Adhere 2 into aluminum channel to create pocket for paper insert provided by Owner.

3. Spacer Panel to be 1/8” rigid PVC board Sintra in standard black. R 1/2" Permanently attached to Back Panel. /8"

1'-0" 3 9 7 4. Middle Panel to be 1/4” rigid PVC 4 board Sintra in standard black. Permanently attached to Middle 5 Panel. 5. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle Panel on all four sides. Provide

4" 1 vinyl backup plate to match V-5 3 / Silver for glass-mount conditions. 4" 1 / Front Elevation 6. Complete assembly to be 2 mounted with low-VOC thin-mil Scale : 3” = 1’ - 0” VHB Tape and low-VOC silicone adhesive. Sign to be located at 5’- 0” to center A.F.F. 1/4" 1/2" 1/8" 1/8" 4" 1 /

1 4" 3 / 2 3 /8" 1'-0" 9 7 11 1/8"

4

5 4" 3 / 1 4" 1 / Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.112B INTERIOR SIGNS Section 6

3" 3" INT.22.2 Insert Holder, 8.5 x 11

1. Standard .5” x .75” aluminum “C” channel. Permanently attached to Middle Panel.

2. Window to be 1/8” clear acrylic with routed finger pulls. Adhere into aluminum channel to create pocket for paper insert provided CL by Owner. 3. Spacer Panel to be 1/8” rigid PVC board Sintra in standard black. Permanently attached to Back Panel.

4. Middle Panel to be 1/4” rigid PVC board Sintra in standard black. Permanently attached to Middle Panel. 5'-0" 5. Back Panel to be 1/8” rigid PVC board Sintra in standard black. Inset 1/2” from edge of Middle Panel on all four sides. Provide vinyl backup plate to match V-5 Silver for glass-mount conditions.

6. Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone Mounting Elevation adhesive. Sign to be located at 5’- 0” to center A.F.F. 5 Scale : 1/2” = 1’ - 0”

CL 5'-0"

Mounting Elevation, Alternate 6 Scale : 1/2” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.112C INTERIOR SIGNS Section 6

Hours of Operation Monday - Friday 8am - 5pm Fourth Tuesday of each month 1pm - 5pm

To schedule appointments, please call: 713-526-4243 In case of emergency, please call: 911

INT.23 Entrance Glass Graphics 1 Scale : 3/4” = 1’ - 0”

INT.23 Entrance Glass Graphics Glass-mounted entrance identification used to display the facility name, hours of operation and any additional information relating to accessing the facility .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.113 INTERIOR SIGNS Section 6

INT.23 Entrance Glass Graphics

1 . First surface applied exterior- EQ EQ grade digitally printed logo circle with matte UV coating OR vinyl to match V-2 White, V-5 Blue and 1'-10" max message length V-7 Tan .

2 . First surface applied exterior- grade vinyl text . Color as described below . Font and

7" Symbol to match HCHD graphic 1 standards for facility logos .

3 . First surface applied exterior- grade vinyl text . Color as described below . Horizontal 2 1/4"

1 3/4" 2 width to match facility name text . 2 1/4" 3/8" 4 . First surface applied exterior- 3/4" 1/8" 3 grade vinyl text . Color as described below . Font: Univers or 1 1/8" 1" 1 3/8" 4 other sans serif font as approved by HCHD graphic standards . 3 3/4" 3/4" Hours of Operation 5 . First surface applied exterior- 5 grade vinyl text . Color as

1 1/2" Monday - Friday 8am - 5pm described below . Font: Helvetica LT Std Bold . 1 1/2" Fourth Tuesday of each month 1pm - 5pm 6 1/2" 2" 6 . First surface applied exterior- To schedule appointments, please call: 713-526-4243 6 grade vinyl text . Color as 1" In case of emergency, please call: 911 described below . Font: Helvetica

1 1/2" LT Std Roman . 7 7 . If appropriate, credit card decals to be provided by others .

Varies By Message 1" 5" 8 . Sign to be located with top of logo mounted at 6’-0” A .F .F . Center horizontally on glass panel . 1/2" 1/2" 1/2" Field verify glass conditions prior to fabrication. Front Elevation

2 Scale : 1 1/2” = 1’ - 0” For clear glass locations: Vinyl text to match V-5 Blue .

For tinted glass locations: Vinyl text to match V-2 White .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.114 INTERIOR SIGNS Section 6

23'-5 3/8"

SURGERY WAITING

DOORS ON HOLD 9'-6" NS TO WAITING OOM ENTRY

INT.25 Welcome Identity - Purple Elevator Lobby 1 Scale : 1/4 ” = 1’ - 0”

21'-3 7/8"

SURGERY WAITING 7'-8"

INT.25 Welcome Identity - Yellow Elevator Lobby 1 Scale : 1/4 ” = 1’ - 0”

INT.25 Welcome Identity Wall-mounted, brushed and polished aluminum letterforms applied onto a clear acrylic panel and mounted to the wall with silver pucks. Letterforms used to identify the lobby of the yellow and purple elevators. This sign may be used to direct for multiple directions. When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers. Used only where visibility is not compromised. .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.115 INTERIOR SIGNS Section 6

8'-0" 0" 2' - 6" SURGERY WAITING

Front Elevation 2 Scale : 1/2” = 1’ - 0”

1/8" 1/8"

INT.25 Welcome Identity

1. Text to be 1/8” thick horizontally brushed aluminum, with bead- blasted returns. Font: Helvetica LT Std Roman.

2. 1 1/2” Thick acrylic with faces and 1 return to be smooth polished and to be puck mounted 1/4” off the wall.

3. 1/2” Non-corrosive stainless steel pucks. Fabricator to confirm the 2 puck layout and configuration, per SURGERYacrylic weight. W

3

Logo Detail 4 Scale : 1 1/2” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.116 INTERIOR SIGNS Section 6

INT.26 Department idnetity 1 Scale : 1/2” = 1’ - 0”

NOTE: HCHD Logo used For Placement Only, until logos are developed or further researched for actual artwork at each relevant clinic.

INT.26 Department Identity Wall-mounted, brushed aluminum letterforms used to identify major entrance into a facility or wing of a facility . This sign may be used to direct for multiple directions, but must have a minimum of 3” high copy to satisfy ADA requirements . When specifying sign location, be aware of ceiling-mounted obstructions such as exit lights or fire sprinklers . Maintain 84” clearance or greater at all locations . Use only where visibility is not compromised

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.117 INTERIOR SIGNS Section 6

INT.26 1'-7" Department Identity 1'-5" 1/4" 1a . Logo type to be 1/4” thick polished aluminum, with bead- blasted returns applied over . .

1b . Symbol to be 1/4” thick polished aluminum, with bead-blasted returns applied over . . 7 1/2" 1c . Middle panel to be 1/4” thick horizontally aluminum, with 1a bead-blasted returns applied over . . 1'-7" 1'-5" 1b 1d . Back panel to be 1/4” thick polished aluminum, with bead- 1c blasted returns . 7 1/2" 1d 2 . Complete assembly to be mounted with threaded studs and low-VOC silicone adhesive, centered left-to-right on existing stone-clad column .

Logo Detail Side View 2 Scale : 1 1/2” = 1’ - 0” 3 Scale : 1 1/2” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.118 GARAGE SIGNS Section 6

8'-0"

Westland Specialty Clinic 1'-3" Patient Parking

GAR.01.1 Garage Entrance Identity, Large 1 Scale : 1/2” = 1’ - 0”

Westland Specialty Clinic Physicians Parking

Exit Only Do Not Enter

Alternate Layouts 2 Scale : 1/2” = 1’ - 0”

Exit Only Westland Specialty Clinic Westland Specialty Clinic Do Not Enter Patient Parking Physicians Parking

Location Elevation 3 Scale : 1/8” = 1’ - 0”

GAR.01.1 Garage Entrance Identity, Large Façade-mounted, 2” deep fabricated aluminum sign used to identify entrances and exits of garage . Signs painted two colors, with applied reflective vinyl in 2 colors, red and white or black and white.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.119 GARAGE SIGNS Section 6

GAR.01.1 Garage Entrance Identity, Large

1 . Message Panel to be 1/8” thick aluminum, painted to match P-1 Black and permanently attached to fabricated sign can .

2 . Fabricated sign can to be 1/8” thick face (message panel) and returns (top and bottom, left and right), seemlessly fabricated 8'-0" around an internal frame structure . All exposed surfaces to 6/Page 5.2 be painted to match P-1 Black .

3 . Internal frame structure to be standard 1/8” thick wall clear anodized aluminum channel with

1 '- 3" 1 mitred corners and to create 2” thick sign can .

4 . Complete sign assembly to Front Elevation be installed onto existing architectural façade with 4 Scale : 1/2” = 1’ - 0” threaded studs set into a two- part epoxy grout .

2 1/8" 1/8" 2"

1 1 2 4 3 1 '- 3"

Side Section 6 Full Size

Side Elevation 5 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 6.120 GARAGE SIGNS Section 7

1' - 3" 7' - 9"

1' - 0" 3 1/2" 7' - 2" max message length

8/Page 5.3

Westland Specialty Clinic 1 '- 3" Patient Parking

Front Message Panel 7 Scale : 1/2” = 1’ - 0”

1' - 0" 2

1 6 1/2" 4" Westland Specialty Clinic 1' - 0" 1 '- 1/2" 4" 5 1/2" Patient Parking

Message Detail 3 8 Scale : 1” = 1’ - 0” 4

GAR.01.1 Garage Entrance Identity, Large

1 . Message Panel to be 1/8” thick aluminum, painted to match P-1 Black and permanently attached to fabricated sign can .

2 . Applied computer-cut vinyl to match 2-colors, V-1 White and V-2 Black or V-1 White and V-3 Red as needed, per provided artwork .

3 . Applied computer-cut vinyl to match V-1 White . Font” Helvetica LT Standard Roman .

4 . Applied computer-cut vinyl to match V-1 White . Font” Helvetica LT Standard Bold .

5 . Complete sign assembly to be installed onto existing architectural façade with threaded studs set into a two- part epoxy grout .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.1 GARAGE SIGNS Section 7

6'-0"

Parking Garage 1' - 0" Elevator Lobby

GAR.01.2 Garage Entrance Identity, Small 1 Scale : 1/2” = 1’ - 0”

Garage Elevators To Westland Specialty Clinic

Walkway To Garage Elevators

Alternate Layouts 2 Scale : 1/2” = 1’ - 0”

1' - 0" 5' - 0"

9 3/4" 2 1/2" 4' - 7 1/2" max message length

4/Page 5.4

Parking Garage 1' - 0" Elevator Lobby

Front Message Panel 3 Scale : 1/2” = 1’ - 0” 5 1/8" 3" Parking Garage 11" 1 '- 0" 3" 4 1/4" Elevator Lobby

Message Detail 4 Scale : 1” = 1’ - 0”

GAR.01.2 Garage Entrance Identity, Small Façade-mounted, 1” deep fabricated aluminum sign used to identify entrances and exits of garage . Signs painted two colors, with applied reflective vinyl in 2 colors, red and white or black and white.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.2 GARAGE SIGNS Section 7

6'-0"

8" CLEARANCE 7’ - 2”

GAR.02 Clearance Identity 1 Scale : 1/2” = 1’ - 0”

CLEARANCE 8’ - 0”

EXIT ONLY

Alternate Layouts 2 Scale : 1/2” = 1’ - 0”

EXIT ONLY CLEARANCE 7’ - 2” CLEARANCE 8’ - 0”

Location Elevation 3 Scale : 1/8” = 1’ - 0”

GAR.02 Clearance Identity Suspended signs used to identify entrance clerances of garage . Signs to be 8” O .D . PVC Pipes, with ends capped and sealed, painted two colors, with applied reflective vinyl in 2 colors.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.3 GARAGE SIGNS Section 7

13' - 0"

Patient Drop Off Area Parking / Parking 1'-6" Exit to Kelly Street

INT.03.1 Overhead Directional, Large 1 Scale : 1/2” = 1’ - 0”

Patient Drop Off Area Parking / Parking Exit to Kelly Street

Location Elevation 2 Scale : 3/8” = 1’ - 0”

GAR.03.1 Overhead Directional, Large Suspended signs Used to identify directions and destinations, within garage . Signs to be 1/2” thick Komatex® Sign Foam, painted two colors, with applied reflective vinyl in 2 colors.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.4 GARAGE SIGNS Section 7

10' - 4"

Exit to Kelly Street Parking / Parking 1'-0" Physician Parking

INT.03.2 Overhead Directional, Small 1 Scale : 1/2” = 1’ - 0”

Exit to Kelly Street Parking / Parking Physician Parking

Location Elevation 2 Scale : 3/8” = 1’ - 0”

GAR.03.2 Overhead Directional, Small Suspended signs Used to identify directions and destinations, within garage . Signs to be 1/2” thick Komatex® Sign Foam, painted two colors, with applied reflective vinyl in 2 colors.

For locations of greater visibility or decision points, use sign type GAR 03. 1.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.5 GARAGE SIGNS Section 7

7'-0"

All Traffic Exit 1'-0" Up To Roof

INT.03.3 Overhead Directional, Wall Mounted 1 Scale : 1/2” = 1’ - 0”

All Traffic Exit Up To Roof

Location Elevation 2 Scale : 3/8” = 1’ - 0”

GAR.03.3 Overhead Directional, Wall Mounted Wall or Soffitt mounted signs Used to identify directions and destinations, within garage . Signs to be 1/8” thick aluminum panels, painted two colors, with applied reflective vinyl in 2 colors.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.6 GARAGE SIGNS Section 7

1'-3" Level 1'-9" 1

INT.04 Level Identity 1 Scale: 1 1/2” = 1’ - 0”

Level 1

Location Elevation 2 Scale : 3/8” = 1’ - 0”

GAR.04 Level Identity Column mounted signs Used to identify individual levels, within garage . Signs to be 1/8” thick aluminum panels, painted two colors, with applied reflective vinyl in 1 color.

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.7 GARAGE SIGNS Section 7

11 1/2"

LEVEL 2

Map Artwork Not In Graphic Designer’s Scope of Work.

Awarded Signage Contractor responsible for the creation of all map artwork,

1'-5 1/4" based on one “Go By” provided by Graphic Designer.

In Case Of Fire, Do Not Use Elevators. Use Designated Fire Exits.

GAR.05 Elevator Call Button Map 1 Scale : 3” = 1’ - 0”

GAR.05 Elevator Call Button Map A wall-mounted sign posted immediately above staff elevator call button which posts specific information required by governing Building or Fire Codes . Sign to be 1/4” clear acrylic, with second-surface silkscreen printed map (in 2 colors) and copy (1 color) .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.8 GARAGE SIGNS Section 7 11 1/2" GAR.05 1/4" 11" 1/4" Elevator Call Button Map

1/4" 1 . Message Panel to be 052”. Rowmark Lasermark engraving material to match 922-402 Black / White . Permanently attached to Middle Panel . 1 Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

2 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel . 2 3 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle 1'-5 1/4" 1'-4 3/4" Panel on all four sides . Provide 3 vinyl backup plate to match V-5 Silver for glass-mount conditions .

4 . Laser engraved text and map artwork . Font: Helvetica LT Std Roman .

5 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be centered 3” above elevator call button panel . 1/4"

Front Elevation 2 Scale : 3” = 1’ - 0” 1/4" 1/8" 1/4" 1

2 1'-5 1/4" 1'-4 3/4"

3 1/4"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.9 GARAGE SIGNS Section 7

GAR.05 Elevator Call Button Map

1 . Message Panel to be 052”. Rowmark Lasermark engraving material to match 922-402 Black / White . Permanently attached to Middle Panel .

Rowmark, LLC 2040 Industrial Drive Findlay, Ohio 45840 419 .425 .8974 www .rowmark com.

2 . Middle Panel to be 1/4” rigid PVC 1/2" 10" max message length 1/2" board Sintra in standard black . Permanently attached to Back Panel .

3 . Back Panel to be 1/8” rigid PVC

1/2" board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

4 . Laser engraved text and map artwork . Font: Helvetica LT Std Map Artwork Roman . Not In Graphic Designer’s Scope of Work. 4 5 . Complete assembly to be Awarded Signage Contractor mounted with low-VOC thin-mil responsible for the creation of all map artwork, 1' - 1" VHB Tape and low-VOC silicone based on one “Go By” provided adhesive . Sign to be centered 3” by Graphic Designer. above elevator call button panel .

1 1/4" Single Message Text 7/8" 1/2" Single Message Text

1 1/4" Multiple Message Text 1/2"

Message Panel 4 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.10 GARAGE SIGNS Section 7

9"

EXIT STAIR A 7 5/8" NO RE-ENTRY NO ROOF ACCESS

GAR.06 Stair Corridor Identity 1 Scale : Half-Sized

GAR.06 Stair Corridor Identity A wall-mounted sign with raised copy and braille, used to label stair designation (Stair A, Exit Stair B, etc .) Specific messages are governed by County Fire Codes . Sign to be 1/4” thick exterior grade photoplymer, painted 1 color with 1 color screen printed tactile copy; over 1/8” rigid PVC board Sintra in standard black .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.11 GARAGE SIGNS Section 7

GAR.06 Stair Corridor Identity 9" 1 . Message Panel to be 059”. 1/4" 8 1/2" 1/4" exterior photopolymer painted to match P-1 Black . Permanently

1/4" attached to Middle Panel .

2 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back 1 Panel .

3 . Back Panel to be 1/8” rigid PVC 2 board Sintra in standard black . 7 1/8" 7 5/8" Inset 1/2” from edge of Middle Panel on all four sides . Provide 3 vinyl backup plate to match V-5 Silver for glass-mount conditions .

4 . Raised text painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Bold . 1/4" Front Elevation 5 . Raised text painted to match P-2 White . Grade 2 Braille left 2 Scale : 3” = 1’ - 0” unpainted . Font: Helvetica LT Std Roman .

6 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone 1/4" 1/8" adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side of door . 1/4" 1 7 1/8" 7 5/8"

2

3 1/4"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.12 GARAGE SIGNS Section 7

GAR.06 Stair Corridor Identity

1 . Message Panel to be 059”. exterior photopolymer painted to match P-1 Black . Permanently attached to Middle Panel .

2 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

3 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide vinyl backup plate to match V-5 Silver for glass-mount conditions .

4 . Raised text painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Bold .

5 . Raised text painted to match 1/2" 7 1/2" max message length 1/2" P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman .

6 . Complete assembly to be

1 7/8" mounted with low-VOC thin-mil 1" STAIR IDENTIFICATION TEXT 4 VHB Tape and low-VOC silicone adhesive . Sign to be located at

1 1/2" STAIR IDENTIFICATION TEXT 5’- 0” to center A .F .F . and 3” from strike side of door . 5/8"

1" SECONDARY TEXT 5/8" 5

1 1/8" SECONDARY TEXT 5/8"

Message Panel 4 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.13 GARAGE SIGNS Section 7

1'-2 1/2"

STAIR LEVEL A 2 LEVELS 1-4 1'-3 3/4" 1'-3 NO RE-ENTRY NO ROOF ACCESS EXIT LEVEL 1

GAR.07 Stairwell Identity 1 Scale : 3” = 1’ - 0”

GAR.07 Stairwell Identity A wall-mounted sign with raised copy and braille, located inside the stairwell, to designate stair level and re- entry information . Specific messages are governed by County Fire Codes . Locate on wall to insure visibility when door is opened or closed . Sign to be 1/4” thickexterior grade photoplymer, painted 1 color with 1 color screen printed tactile copy; over 1/8” rigid PVC board Sintra in standard black .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.14 GARAGE SIGNS Section 7

GAR.07 1'-2 1/2" Stairwell Identity

1/4" 1'-2" 1/4" 1 . Message Panel to be 059”. exterior photopolymer painted 1/4" to match P-1 Black . Permanently attached to Middle Panel .

2 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . 1 Permanently attached to Back Panel .

3 . Back Panel to be 1/8” rigid PVC 2 board Sintra in standard black . Inset 1/2” from edge of Middle Panel on all four sides . Provide 3 vinyl backup plate to match V-5 Silver for glass-mount conditions .

4 . Raised text painted to match P-2 White . Grade 2 Braille left 1'-3 1/4" 1'-3 1'-3 3/4" 1'-3 unpainted . Font: Helvetica LT Std Bold .

5 . Raised text and symbols painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman .

6 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from strike side of door .

Front Elevation 1/4" 2 Scale : 3” = 1’ - 0”

1/4" 1/8" 1/4" 1 1'-3 1/4" 1'-3 1'-3 3/4" 1'-3

2

3 1/4"

Side Elevation 3 Scale : Half-Sized

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.15 GARAGE SIGNS Section 7

GAR.07 Stairwell Identity

1 . Message Panel to be 059”. exterior photopolymer painted to match P-1 Black . Permanently attached to Middle Panel .

2 . Middle Panel to be 1/4” rigid PVC board Sintra in standard black . Permanently attached to Back Panel .

3 . Back Panel to be 1/8” rigid PVC board Sintra in standard black . 4 1/4" 4 1/4" Inset 1/2” from edge of Middle Panel on all four sides . Provide 7" 7" vinyl backup plate to match V-5 Silver for glass-mount conditions .

1/2" 1'-1" max message length 1/2" 4 . Raised text painted to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Bold .

2" 5 . Raised text and symbols painted 1" 4 STAIR LEVEL to match P-2 White . Grade 2 Braille left unpainted . Font: Helvetica LT Std Roman . STAIR LEVEL 2 1/2" 2" 4 IDENTIFICATION IDENTIFICATION 6 . Complete assembly to be mounted with low-VOC thin-mil VHB Tape and low-VOC silicone 5/8" adhesive . Sign to be located at 5’- 0” to center A .F .F . and 3” from

1 7/8" strike side of door . 1" STAIR LEVEL ACCESS TEXT 5 5/8" 1 5/8" 1" RE-ENTRY TEXT 3/4" 1 1/2" 1" ROOF ACCESS TEXT 3/4" 1 1/2" 1" EXIT LEVEL TEXT 3/4"

1/2"

Message Panel 4 Scale : 3” = 1’ - 0”

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.16 GARAGE SIGNS Section 7

9"

105 5" Mechanical / Electrical Room

GAR.08 Typical Room Identity 1 Scale : Half-Sized

GAR.08 Typical Room Identity A wall-mounted sign with raised copy and braille . Used to identify permanent rooms with fixed messages . Sign to be 1/4” thick exterior grade photopolymer, painted 1 color with 1 color screen printed tactile copy and 1/4” thick acrylic with screen-printed room name; over 1/8” rigid PVC board Sintra in standard black .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.17 GARAGE SIGNS Section 7

1' - 6" 1' - 1/8" 9" 6 1/2" 2' - 0" 3"

1 1/2" RESERVED 2 1/2" 1 1/2" PARKING 3"

1" Violators Will Be Towed

INT.09 ADA Parking Identity 1 Scale : 1 1/2” = 1’ - 0”

RESERVED PARKING

Violators Will Be Towed

Location Elevation 2 Scale : 3/8” = 1’ - 0”

GAR.09 ADA Parking Identity A post-mounted sign located at all ADA Accessible parking spaces . Signs to be 1/8” thick aluminum painted one color on all exposed surfaces, with applied reflective vinyl in 2 colors. Sign mounted to 2” x 2” square tube posted with blind studs and installed via 1/4” thick mounting plate, painted 1 color, to existing concrete deck .

HCHD SIGNAGE MASTER PLAN 6 DECEMBER 2010 Page 7.18 English Vietnamese FLOOR LẦU ROOM PHÒNG