O&C GENERAL CATALOGUE ELECTRIC STRIKES wind, badinstallation,etc). It’s force(doorweight, onthekeeperbyanexternal thepressureexerted Side-Load control systemfromcurrentpeaks. blockprotectsyouraccess A transilsuppressorwithintheterminal Electronic protection * withanykindoflatch. work perfectly Keepers (fixedoradjustable,deepshallow)allowthestriketo Keeper manually switchedback. openeduntil Activating thisleverwillkeepthestrikepermanently Mechanical unlocking control orinterlockingsystem. This functionwillsignalizethestatusofdoortoyouraccess Monitoring holds thestrikeunlockeduntildoorisopened. This functionallowsunlockingwithasingleelectricimpulseand Hold-open * installedintoanykindofframe. perfectly shapesandfinishes,allowthestriketobe Faceplates, indifferent Faceplate and receivethelatchbolt. openers) replaceastandardstrikemountedonthedoorframe Electric strikes(alsocalledelectriclatchreleaseordoor Electric strike Glossary Personalized keepersareavailableuponrequest. Personalized faceplatesareavailableuponrequest. 5 53.1.28.B Reference Example 6 5 4 3 2 1 Model 2 6 4 keeper cover Terminal block mechanical unlocking hold-open pin faceplate 3 Keeper Faceplate Coil 1 JANUARY 2012ISSUE 1

Electric strikes

Hold-open with mechanical unlocking Hold-open The electric strike is unlocked when energized. The electric strike is unlocked when the status of the . It features a microswitch that detects (opened/closed) Fail-secure with double monitoring energized. The electric strike is unlocked when the status of both the It features 2 microswitches that detect (locked/unlocked). door (opened/closed) and the keeper The pin on the keeper allows unlocking the strike through a single electric impulse. The strike will stay unlocked until the actual opening of the door. The pin on the keeper allows unlocking the strike through a single electric impulse. The strike will stay unlocked until the actual opening of the door. It features a mechanical lever for manual release. The electric strike is unlocked when energized. The electric strike is unlocked when release. It features a mechanical lever for manual Fail-secure with monitoring The electric strike is unlocked when energized. The electric strike mechanical unlocking Fail-secure with Fail-secure FUNCTIONS 2 JANUARY 2012 ISSUE JANUARY Electric strikes It featuresamechanicalleverformanualrelease. The strikewillstayunlockeduntiltheactualopening ofthedoor. single electricimpulse. deviceallows unlockingtheelectricstrikethrougha An internal Internal Hold-openwithmechanicalunlocking The strikewillstayunlockeduntiltheactualopeningofdoor. single electricimpulse. deviceallows unlockingtheelectricstrikethrougha An internal Internal Hold-open door (opened/closed)andthekeeper(locked/unlocked). It features2microswitchesthatdetectthestatusofboth The electricstrikeislockedwhenenergized. Fail-safe withdoublemonitoring (opened/closed) It featuresamicroswitchthatdetectsthestatusofdoor. The electricstrikeislockedwhenenergized. Fail-safe withmonitoring The electricstrikeislockedwhenenergized. Fail-safe interal hold-openmodel fail-safe model JANUARY 2012ISSUE 3

Electric strikes DIN left 24.0.9A.M 20.0.9A.B 12A.0.9A.B 9A for 90mm 12B for 120mm References RIM Series 1 & 2 RIM DIN right 14.0.9B.M 10.0.9B.B 12A.0.9B.B 9B for 90mm 12A for 120mm References Series 5 MINI 52.1.00.B 52.1.00.J 53.1.00.B 53.1.00.J 54.1.00.E 54.1.00.F 58.1.00.E 58.1.00.F 50.1.00.E 50.1.00.F 50.1.00.B 50.1.00.J 51.1.00.E 51.1.00.F 51.1.00.B 51.1.00.J 56.1.00.E 56.1.00.F 56.1.00.B 56.1.00.J add faceplate References Series 3 30.1.00.B 30.1.00.J 30.1.00.E 30.1.00.F 31.1.00.B 31.1.00.J 31.1.00.E 31.1.00.F 32.1.00.B 32.1.00.J 32.1.00.E 33.1.00.B 33.1.00.J 33.1.00.E 32A.1.00.B 32A.1.00.J 33A.1.00.B 33A.1.00.J 34.1.00.E 34.1.00.F add faceplate References SYMMETRIC DIN left 20.0.00.B 20.0.00.J 20.0.00.E 20.0.00.F 20.1.00.B 20.1.00.J 20.1.00.E 20.1.00.F 21.0.00.B 21.0.00.J 21.0.00.E 21.0.00.F 21.1.00.B 21.1.00.J 21.1.00.E 21.1.00.F 22.0.00.B 22.0.00.J 22.1.00.B 22.1.00.J 23.0.00.B 23.0.00.J 23.1.00.B 23.1.00.J 22A.0.00.B 22A.0.00.J 22A.1.00.B 22A.1.00.J 23A.0.00.B 23A.0.00.J 23A.1.00.B 23A.1.00.J add faceplate References BASIC Series 1 & 2 DIN right 10.0.00.F 10.0.00.B 10.0.00.J 10.0.00.E 10.1.00.B 10.1.00.J 10.1.00.E 10.1.00.F 11.0.00.B 11.0.00.J 11.0.00.E 11.0.00.F 11.1.00.B 11.1.00.J 11.1.00.E 11.1.00.F 12.0.00.B 12.0.00.J 12.1.00.B 12.1.00.J 13.0.00.B 13.0.00.J 13.1.00.B 13.1.00.J 12A.0.00.B 12A.0.00.J 12A.1.00.B 12A.1.00.J 13A.0.00.B 13A.0.00.J 13A.1.00.B 13A.1.00.J add faceplate References ac/dc 9-16 V ac/dc 9-14 V ac/dc 8-14 V ac/dc 6-12 V VOLTAGE ac/dc 5-12 V 24 Vdc

12 Vdc

Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Fixed Keeper Fixed Adjustable Adjustable Adjustable Adjustable Adjustable Adjustable Adjustable Adjustable Adjustable

STRIKES ELECTRIC ELECTRIC Internal unlocking monitoring Fail-secure unlocking Fail-safe unlocking mechanical mechanical Hold-open Hold-open monitoring Fail-safe with Fail-secure with Fail-safe with Fail-secure with Fail-secure with Hold-open with with mechanical double monitoring double monitoring Internal Hold-open 4 JANUARY 2012 ISSUE JANUARY Electric strikes SECURITY HIGH References 258.1.00.F 258.1.00.E 254.1.00.F 254.1.00.E 252.1.00.J 252.1.00.B 256.1.00.J 256.1.00.B 256.1.00.E 250.1.00.B 250.1.00.F 250.1.00.E 256.1.00.F 250.1.00.J add faceplate Series 25 4R6.4.00.L 4R6.4.00.N 4R6.4.00.M 4R0.4.00.N 4R0.4.00.M 4R0.4.00.L 4R8.4.00.N 4R8.4.00.M 4R4.4.00.N 4R4.4.00.M 4R2A.4.00.L References add faceplate DIN right SECURITY Series 4R&4L 49.4.00.N 49.4.00.P 4L8.4.00.N 4L8.4.00.M 4L4.4.00.N 4L4.4.00.M 4L2A.4.00.L 47.4.00.N 47.4.00.P 4L6.4.00.L 4L6.4.00.N 4L6.4.00.M 4L0.4.00.N 4L0.4.00.M 4L0.4.00.L References add faceplate DIN left References 7R6.4.00.L 7R6.4.00.N 7R6.4.00.M 7R0.4.00.N 7R0.4.00.M 7R0.4.00.L 7R8.4.00.N 7R8.4.00.M 7R4.4.00.N 7R4.4.00.M 7R2A.4.00.L add faceplate DIN right WATERPROOF IP 54 Series 7R&7L References 7L6.4.00.N 7L6.4.00.M 7L0.4.00.M 7L0.4.00.L 7L8.4.00.N 7L8.4.00.M 7L4.4.00.N 7L4.4.00.M 7L2A.4.00.L 7L0.4.00.N add faceplate 7L6.4.00.L DIN left 24R6.4.00.L 24R6.4.00.N 24R6.4.00.M 24R0.4.00.N 24R0.4.00.M 24R0.4.00.L 24R8.4.00.N 24R8.4.00.P 24R4.4.00.N 24R4.4.00.P References add faceplate DIN right RF 120 Series 24R&24L FIRE 24L8.4.00.N 24L8.4.00.P 24L4.4.00.N 24L4.4.00.P 24L6.4.00.L 24L6.4.00.N 24L6.4.00.M 24L0.4.00.N 24L0.4.00.M 24L0.4.00.L References add faceplate DIN left EMERGENCY References 42A.6.00.L 40.6.00.M 48.6.00.M 44.6.00.M 46.6.00.M 40.6.00.N 49.6.00.N 48.6.00.N 44.6.00.N 47.6.00.N 46.6.00.N 49.6.00.P 47.6.00.P 46.6.00.L 40.6.00.L Series 4 add box References 9R0.1.00.L 9R0.1.00.N 9R0.1.00.M 9R4.1.00.N 9R4.1.00.M 9R3A.1.00.L 9R2A.1.00.L add faceplate DIN right ARMOURED Series 9R&9L 9L0.1.00.L 9L0.1.00.N 9L0.1.00.M 9L4.1.00.N 9L4.1.00.M 9L3A.1.00.L 9L2A.1.00.L References add faceplate DIN left JANUARY 2012ISSUE 5

Electric strikes 5 5 5/12 V ac/dc 24 V dc 100% (220 Ω 0,12A) (8 Ω 0,6A at 6 V ac) J F Minutes Hours (at 9 V ac) °C °C 65 77 5 5 Personalized coils upon request 8/14 V ac/dc 12 V dc 100% (60 Ω 0,20A) (12 Ω 0,7A at 12 V ac) B E Minutes (at 12 V ac) Hours °C °C Series 1 & 2 Coil features • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 3.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Zamak Keeper: Zamak • Guaranteed 3 years 55014) • Complies with 2004/108/CE (EN ISO 9227 • Corrosion resistant according to UNI Basic electric strikes are ideal for simple ironmongerystrikes are ideal for Basic electric as such installations, with fixed or adjustable keeper, phones. They are available door home or left . for either DIN right strikes quickly variety of functions and voltages, these Featuring a wide consumption. unlock standard doors through low power features Technical 53 BASIC 105 6 JANUARY 2012 ISSUE JANUARY Electric strikes 84 81 80 66 61 01 BOX SHORT References andfeatures Recommended Faceplates Brass Chrome Grey Grey Grey Inox Inox Grey D4 D3 C65 C64 C63 74 73 67 65 64 63 43 21 20 05 04 03 LONG Grey|Brown Grey|Brown Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Grey|Brown Grey|Brown Grey|Brown with mechanicalunlocking Internal Hold-open with mechanicalunlocking Hold-open Internal Hold-open Hold-open with mechanicalunlocking Fail-secure Fail-secure 17 16 15 14 13 12 11 10 09 08 Deep adjustablekeeper Supplied uponrequest ANGLED Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown 43,2 46,2 Shallow adjustablekeeper Supplied uponrequest BK3

16,5 43,2 46,2 keeper Fixed 8,25 13,3 12,7 12,7 keeper Adjustable 16,5 7,75 BK2

Shim kit 7 ESP2 6,15 12,7 33,4 Side-load 12,7

90,4

52

9,4 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 6-12 Vac/dc 9-14 Vac/dc 6-12 Vac/dc 9-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 6-12 Vac/dc 9-14 Vac/dc 6-12 Vac/dc 9-14 Vac/dc Voltage 21,3 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc Dimensions 9,7 46,8 33,5 20,7 Keeper’s adjustability: 3mm References add faceplate DIN right 13.1.00.J 13.1.00.B 13.0.00.J 13.0.00.B 12A.1.00.J 12A.1.00.B 12A.0.00.J 12A.0.00.B 11.0.00.E 11.0.00.J 11.0.00.B 10.0.00.E 10.0.00.J 10.0.00.B 13A.1.00.J 13A.1.00.B 13A.0.00.J 13A.0.00.B 12.1.00.J 12.1.00.B 12.0.00.J 12.0.00.B 11.1.00.F 11.1.00.E 11.1.00.J 11.1.00.B 11.0.00.F 10.1.00.F 10.1.00.E 10.1.00.J 10.1.00.B 10.0.00.F

6,45

23.1.00.J 23.1.00.B 23.0.00.J 23.0.00.B 22A.1.00.J 22A.1.00.B 22A.0.00.J 22A.0.00.B 21.0.00.E 21.0.00.J 21.0.00.B 20.0.00.E 20.0.00.J 20.0.00.B 23A.1.00.J 23A.1.00.B 23A.0.00.J 23A.0.00.B 22.1.00.J 22.1.00.B 22.0.00.J 22.0.00.B 21.1.00.F 21.1.00.E 21.1.00.J 21.1.00.B 21.0.00.F 20.1.00.F 20.1.00.E 20.1.00.J 20.1.00.B 20.0.00.F add faceplate DIN left References 28 JANUARY 2012ISSUE 52,3

90 7

Electric strikes 5 5 5/12 V ac/dc (8 Ω 0,6A at 6 V ac) 24 V dc 100% (185 Ω 0,12A) J F Minutes (at 9 V ac) Hours °C 65 °C 57 5 5 12 V dc 100% (50 Ω 0,25A) 8/14 V ac/dc Personalized coils upon request (14 Ω 0,7A at 12 V ac) E B Hours Minutes (at 12 V ac) °C Coil features Technical Features Technical • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 3.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Zamak Keeper: Zamak • Guaranteed 3 years 55014) • Complies with 2004/108/CE (EN • Corrosion resistant according to UNI ISO 9227 SYMMETRIC Series 3 market. They are strikes are the most common on the Symmetrical electric keeper. and feature an adjustable 100% reversible order to prevent with electronic protection in DC models are equipped an advantage control system. This also represents damages to your access polarized. for the installer as the connection is not voltages, these strikes quickly unlock Featuring a wide variety of functions and standard doors through low power consumption. °C 63 60 8 JANUARY 2012 ISSUE JANUARY Electric strikes 84 81 92 66 62 61 02 01 BOX SHORT References andfeatures Recommended Faceplates Brass Chrome Grey Grey Inox Inox Inox Inox Grey Grey D4 C65 C64 74 73 71 65 64 21 20 05 04 LONG Grey|Brown Inox Inox Inox Inox Inox Inox Inox Inox Inox Grey|Brown Grey|Brown Fail-safe with mechanicalunlocking Internal Hold-open with mechanicalunlocking Hold-open Internal Hold-open Hold-open with mechanicalunlocking Fail-Secure Fail-secure 17 16 13 12 09 08 ANGLED Brown Brown Brown Brown Brown Brown Shim kitinstallation Supplied uponrequest 11,6 Deep adjustablekeeper Reversible 44,7 47,1 keeper Adjustable 12 5,4

69,3 14,7 SK3 12,7 52 13,5

12

Side-load

ESP3 5,5 21,3 protection Electronic Dimensions 10,7 47,6 10,7

Keeper’s adjustability: 3mm 21 5-12 Vac/dc 8-14 Vac/dc 6-12 Vac/dc 9-14 Vac/dc 6-12 Vac/dc 9-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc Voltage 24 Vdc 12 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 12 Vdc

add faceplate References

34.1.00.F 34.1.00.E 33.1.00.E 33.1.00.J 33.1.00.B 32A.1.00.J 32A.1.00.B 31.1.00.F 31.1.00.E 31.1.00.J 31.1.00.B 30.1.00.F 30.1.00.E 30.1.00.J 30.1.00.B 33A.1.00.J 33A.1.00.B 32.1.00.E 32.1.00.J 32.1.00.B 29 52 JANUARY 2012ISSUE 69 9

Electric strikes 5 24 V dc 100% (192 Ω 0,120A) F Hours °C 62 5 Personalized coils upon request (42 Ω 0,275A) 12 V dc 100% E Hours °C 68 9 Vac 6 Vac 12 Vac 5 (8,5 Ω 0,820A at 9V ac) 6/12 V ac/dc J Minutes °C 58 39 85 9 Vac 16 Vac 12 Vac 5 9/16 V ac/dc (20 Ω 0,480A at 12V ac) -- is one of the electric strike -- only 16 mm wide This 100% reversible and the perfectsmallest on the market as match for narrow profiles such size and high resistance it can wood and PVC. Through its small aluminum, fit any lock. box of the electric strike, so The radial keeper rotates inside the mechanism frame to make it fit. the installer does not have to cut the door protection to prevent damage to All models are equipped with electronic to. This also represents an the system they are connected is not polarized. advantage for the installer as the connection voltages, these strikes quickly unlock Featuring a wide variety of functions and standard doors through low power consumption. Coil features Technical features Technical • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 4.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Zamak Keeper: Zamak • New hold-open system • Guaranteed 3 years • Complies with 2004/108/CE (EN 55014) • Corrosion resistant according to UNI ISO 9227 Series 5 MINI B Minutes °C 77 60 46 10 JANUARY 2012 ISSUE JANUARY Electric strikes References andfeatures 28 27 SHORT Recommended Faceplates Inox Inox Monitoring features: 30 29 26 23 22 LONG Inox Inox Inox Inox Inox Microswitch S1 with monitoring Fail-safe with monitoring Fail-secure with mechanicalunlocking Fail-secure Fail-secure with mechanicalunlocking Hold-open Hold-open Fail-safe ANGLED 25 24 Inox Inox keeper adjustable Radial Life Expectancy* Humidity Ambient Temperature Insulation Resistance Contact Resistance Operating Frequency Operating Speed Intensity 5,4 9,2 45 9,2 16 9,8 Reversible

Keeper’s adjustability: 2mm 28,1 Side-load Dimensions 52,3 Electrical: 30.000operationsminimum Mechanical: 300.000operationsminimum 85% RHmaximum(5°to35°C) From -25°Cto65°C(withoutice) 100 MΩminimum(at500VDC) 50 mΩmaximum Electrical: 30operationsperminute Mechanical: 200operationsperminute 1 at500mm/second(atpinplunger) 0,5A/30V DC 1A/125V AC 65,6 protection Electronic 9,2 47,2 9,2 16 with monitoring 6-12 Vac/dc 9-16 Vac/dc 6-12 Vac/dc 9-16 Vac/dc 6-12 Vac/dc 9-16 Vac/dc 6-12 Vac/dc 9-16 Vac/dc 6-12 Vac/dc 9-16 Vac/dc Voltage 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc

*at maximumpowerconditions 28,1 add faceplate References 51.1.00.B 58.1.00.F 58.1.00.E 51.1.00.F 51.1.00.E 51.1.00.J 50.1.00.F 50.1.00.E 50.1.00.J 50.1.00.B 56.1.00.F 56.1.00.E 56.1.00.J 56.1.00.B 53.1.00.J 53.1.00.B 52.1.00.J 52.1.00.B 54.1.00.F 54.1.00.E 52,3 JANUARY 2012ISSUE 72,7 11

Electric strikes 5 FAIL-SAFE FAIL-SECURE 12 Vdc 100% (70 Ω 0,17A) M Hours °C 62 51 Personalized coils upon request 5 8/14 V ac/dc (12 Ω 0,7A at 12 V ac) B Minutes (at 12 V ac) °C RIM RIM Series 1 & 2 Coil features are built with a cavity designed to house the dead Rim strikes are built with a cavity bolt of rim locks. for both for either DIN right or left doors, They are available and verticalhorizontal (90 mm) mm) mechanical locks. (120 and voltages, these strikes Featuring a wide variety of functions low power consumption. quickly unlock standard doors through features Technical • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 5.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Black painted aluminium Keeper: Zamak and the : 5mm • Maximum distance between the bolt • Guaranteed 3 years 55014) • Complies with 2004/108/CE (EN • Corrosion resistant according to UNI ISO 9227 105 12 JANUARY 2012 ISSUE JANUARY Electric strikes 25 50 References andfeatures 22 50

9A /9B 50 Internal Hold-open Fail-secure

52 Fail-safe 31 Dimensions 90 Box 80 120 mm 90 mm 120 mm 90 mm 120 mm 90 mm keeper Fixed 22 keeper Fixed 12A /12B 34 70 9-14 Vac/dc 9-14 Vac/dc 8-14 Vac/dc 8-14 Vac/dc

Voltage 50 12 Vdc 12 Vdc DIN right References 14.0.12A.M 14.0.9B.M 12A.0.12A.B 12A.0.9B.B 10.0.12A.B 10.0.9B.B DIN left References 20.0.9A.B 22A.0.9A.B 20.0.12B.B 24.0.9A.M 22A.0.12B.B 24.0.12B.M JANUARY 2012ISSUE

52 31 120 13

Electric strikes 5 FAIL-SAFE FAIL-SECURE 24 Vdc 100% (240 Ω 0,10A) N Hours °C 66 56 5 FAIL-SAFE Personalized coils upon request FAIL-SECURE 12 Vdc 100% (70 Ω 0,17A) M Hours °C 62 51 5 8/14 V ac/dc (20 Ω 0,5A at 12 V ac) L Minutes (at 12 V ac) Series 7R & 7L Certifications • IP 54 certified (protected against dust and water) Coil features Technical features Technical • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 5.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Zamak Keeper: Zamak • Guaranteed 3 years • Complies with 2004/108/CE (EN 55014) • Corrosion resistant according to UNI ISO 9227 outdoor installations electric strikes are designed for Waterproof particularlyThe curved in wet or dusty areas. of the box design of the base the latch and of locks where the separation between allows the installation 5 mm. the first bolt is only magnetism and it is an O&C patented The model with monitoring operates by the reed box. system which ensures the insulation of protection in order to prevent DC models are equipped with electronic This also represents an advantage damages to your access control system. polarized. for the installer as the connection is not doors and featuring a wide variety Manufactured for right and left opening quickly unlock standard doors through of functions and voltages, these strikes low power consumption. WATERPROOF °C 62 IP54 14 JANUARY 2012 ISSUE JANUARY Electric strikes References andfeatures Recommended Faceplates 76 SHORT Inox REED with monitoring Fail-safe with monitoring Fail-secure Fail-safe Internal Hold-open Fail-secure 75 69 68 LONG Inox Inox Inox Maximum power Maximum current Maximum voltage keeper Fixed 8,81 12,8 Side-load 98,9

93,2 36 3 W 0,3 A 100 VDC Dimensions protection Electronic 8-14 Vac/dc 9-14 Vac/dc 8-14 Vac/dc Voltage

24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 21 add faceplate DIN right References 7R4.4.00.N 7R4.4.00.M 7R6.4.00.N 7R6.4.00.M 7R6.4.00.L 7R2A.4.00.L 7R0.4.00.N 7R0.4.00.M 7R0.4.00.L 7R8.4.00.N 8,9 44,5 45,5 7R8.4.00.M add faceplate DIN left References 7L4.4.00.N 7L4.4.00.M 7L6.4.00.N 7L6.4.00.M 7L6.4.00.L 7L2A.4.00.L 7L0.4.00.N 7L0.4.00.M 7L0.4.00.L 7L8.4.00.N 7L8.4.00.M JANUARY 2012ISSUE 15

Electric strikes 5 FAIL-SAFE FAIL-SECURE 24 Vdc 100% (240 Ω 0,10A) N Hours °C 66 56 5 FAIL-SAFE Personalized coils upon request FAIL-SECURE 12 Vdc 100% (70 Ω 0,17A) M Hours °C 62 51 5 8/14 V ac/dc (20 Ω 0,5A at 12 V ac) L Minutes (at 12 V ac) Series 9R & 9L Coil features Technical features Technical • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 7.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Zamak Keeper: Zamak • Patented coil-fastening system • Guaranteed 3 years • Complies with 2004/108/CE (EN 55014) • Corrosion resistant according to UNI ISO 9227 These electric strikes have been especially designed for armoured have been especially designed for These electric strikes doors between the latch and where the separation secured by multipoint locks 5mm. the first bolt is only order to prevent with electronic protection in DC models are equipped This also represents an advantage damages to your access control system. polarized. for the installer as the connection is not voltages, these strikes quickly unlock Featuring a wide variety of functions and standard doors through low power consumption. ARMOURED °C 62 16 JANUARY 2012 ISSUE JANUARY Electric strikes References andfeatures Recommended Faceplates Deep adjustablekeeper Supplied uponrequest 70 60 LONG Fail-safe with mechanicalunlocking Internal Hold-open Internal Hold-open Fail-secure Inox Inox 34,8 AK3

14,2 9,3 keeper Adjustable 10,8 6 10,8 Side-load protection Electronic

88,8 Keeper’s adjustability:3mm 9-14Vac/dc 9-14Vac/dc

83,3 8-14 Vac/dc Dimensions Voltage 32 24 Vdc 12 Vdc 24 Vdc 12 Vdc

add faceplate DIN right References

9R4.1.00.N 9R4.1.00.M 9R3A.1.00.L 9R2A.1.00.L 9R0.1.00.N 9R0.1.00.M 9R0.1.00.L 23

9 36,1 43,7 add faceplate DIN left References 9L4.1.00.N 9L4.1.00.M 9L3A.1.00.L 9L2A.1.00.L 9L0.1.00.N 9L0.1.00.M 9L0.1.00.L JANUARY 2012ISSUE 17

Electric strikes 5 12 Vdc 100% (54 Ω 0,22 A) P Hours °C 57 5 FAIL-SAFE FAIL-SECURE Personalized coils upon request 24 Vdc 100% (240 Ω 0,10A) N Hours °C 56 66 5 FAIL-SAFE FAIL-SECURE 12 Vdc 100% (70 Ω 0,17A) M Hours °C 51 62 and allow the access from outside through an access an through outside from access the allow and bars panic 5 Series 4 Coil features Technical features Technical • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 7.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Zamak Keeper: Zamak • Patented coil-fastening system • Guaranteed 3 years • Complies with 2004/108/CE (EN 55014) • Corrosion resistant according to UNI ISO 9227 These strikes are designed to be installed on emergency exit doors equipped to be installed on emergency exit These strikes are designed with control system. are these strikes require high level of reliability and safety, Ideal for doors that usually connected with fire control systems. protection in order to prevent DC models are equipped with electronic This also represents an advantage damages to your access control system. polarized. for the installer as the connection is not voltages, these strikes quickly unlock Featuring a wide variety of functions and standard doors through low power consumption. 8/14 V ac/dc EMERGENCY (20 Ω 0,5A at 12 V ac) L Minutes (at 12 V ac) °C 62 18 JANUARY 2012 ISSUE JANUARY Electric strikes References andfeatures Microswitch S1 Recommended Boxes 85 83 82 BOX Black +BaseC83 Black +C83 Black Monitoring features: with doublemonitoring Fail-safe with monitoring Fail-safe with doublemonitoring Fail-secure with monitoring Fail-secure Fail-safe Internal Hold-open Fail-secure Microswitch S2 reversibility Symmetrical 107 Life Expectancy* Protection degree Humidity Ambient Temperature Insulation Resistance Contact Resistance Operating Frequency Operating Speed Intensity

29,5

with doublemonitoring 52 keeper Fixed 9,59 15,4 Electrical: 30.000operationsminimum Mechanical: 300.000operationsminimum 85% RHmaximum(5°to35°C) From -25°Cto65°C(withoutice) 100 MΩminimum(at500VDC) 50 mΩmaximum Electrical: 30operationsperminute Mechanical: 200operationsperminute 1 at500mm/second(atpinplunger) 0,5A/30V DC 1A/125V AC

Side-load

Microswitch S1 20,2 Dimensions 17,3 48 41,1 protection Electronic

106,4

29,5 52 Electrical: 30.000operationsminimum Mechanical: 30.000operationsminimum IP 40 85% RHmaximum(5°to35°C) From -25°Cto70°C(withoutice) 100 MΩminimum(at500VDC) 30 mΩmaximum Electrical: 30operationsperminute Mechanical: 200operationsperminute 1 at500mm/second(atpinplunger) 0,5A/30V DC 8-14 Vac/dc 9-14 Vac/dc 8-14 Vac/dc Voltage 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc Microswitch S2 *at maximumpowerconditions

References add box

49.6.00.N 49.6.00.P 48.6.00.N 48.6.00.M 40.6.00.N 40.6.00.M 47.6.00.N 47.6.00.P 46.6.00.N 46.6.00.M 46.6.00.L 42A.6.00.L 40.6.00.L 44.6.00.N 44.6.00.M 20,2 JANUARY 2012ISSUE

17,3 48 41,1 19

Electric strikes 5 12 V dc 100% (54 Ω 0,22A) P Hours °C 57 5 FAIL-SAFE FAIL-SECURE Personalized coils upon request 24 V dc 100% (240 Ω 0,10A) N Hours °C 66 56 5 FAIL-SAFE FAIL-SECURE 12 V dc 100% (70 Ω 0,17A) M Hours °C 62 51 5 Series 4R & 4L Coil features Technical features Technical • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 7.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Reinforced Zamak Keeper: Steel • Guaranteed 3 years. • Complies with 2004/108/CE (EN 55014) • Corrosion resistant according to UNI ISO 9227 Security electric strikes are designed for doors connected to fire and access are designed for doors connected Security electric strikes a high level of security. systems or doors requiring control higher resistance. has been reinforced, in order to ensure The zamak housing through four supportThe keeper is anchored points. protection in order to prevent DC models are equipped with electronic This also represents an advantage damages to your access control system. polarized. for the installer as the connection is not left opening doors featuring a wide They are manufactured for both right and strikes quickly unlock standard doors variety of functions and voltages, these through low power consumption. 8/14 V ac/dc SECURITY (20 Ω 0,5A at 12 V ac) L Minutes (at 12 V ac) °C 62 20 JANUARY 2012 ISSUE JANUARY Electric strikes References andfeatures 66 61 SHORT Recommended Faceplates Microswitch S1 Inox Inox Monitoring features: 71 67 43 LONG Inox Inox Inox Fail-secure with doublemonitoring Fail-safe with monitoring Fail-safe with doublemonitoring Fail-secure with monitoring Fail-secure Fail-safe Internal Hold-open Microswitch S2 ANGLED 50 49 48 45 17 16 Inox Inox Brown Brown Brown Brown Life Expectancy* Protection degree Humidity Ambient Temperature Insulation Resistance Contact Resistance Operating Frequency Operating Speed Intensity keeper Fixed 107 9,48

29,5 13

with doublemonitoring 52 Side-load Electrical: 30.000operationsminimum Mechanical: 300.000operationsminimum 85% RHmaximum(5°to35°C) From -25°Cto65°C(withoutice) 100 MΩminimum(at500VDC) 50 mΩmaximum Electrical: 30operationsperminute Mechanical: 200operationsperminute 1 at500mm/second(atpinplunger) 0,5A/30V DC 1A/125V AC protection Electronic

Microswitch S1 20,2 Dimensions

17,3 48 41,1 9-14 Vac/dc 8-14 Vac/dc 8-14 Vac/dc Voltage 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 24 Vdc 12 Vdc 12 Vdc 24 Vdc 24 Vdc 12 Vdc 106,4

29,5 52 Electrical: 30.000operationsminimum Mechanical: 30.000operationsminimum IP 40 85% RHmaximum(5°to35°C) From -25°Cto70°C(withoutice) 100 MΩminimum(at500VDC) 30 mΩmaximum Electrical: 30operationsperminute Mechanical: 200operationsperminute 1 at500mm/second(atpinplunger) 0,5A/30V DC add faceplate DIN right References 4R4.4.00.N 4R4.4.00.M 4R8.4.00.N 4R8.4.00.M 4R2A.4.00.L 4R6.4.00.N 4R6.4.00.M 4R6.4.00.L 4R0.4.00.N 4R0.4.00.M 4R0.4.00.L Microswitch S2 *at maximumpowerconditions

References add faceplate DIN left 47.4.00.N 47.4.00.P 4L4.4.00.N 4L4.4.00.M 4L8.4.00.N 4L8.4.00.M 4L2A.4.00.L 49.4.00.N 49.4.00.P 4L6.4.00.N 4L6.4.00.M 4L6.4.00.L 4L0.4.00.N 4L0.4.00.M 4L0.4.00.L 20,2 JANUARY 2012ISSUE

17,3 48 41,1 21

Electric strikes 5 24 V dc 100% (185 Ω 0,12A) F Horas °C 57 5 Personalized coils upon request 12 V dc 100% (50 Ω 0,25A) E Horas °C 63 5 5/12 V ac/dc (8 Ω 0,6A at 6 V ac) J Minutes (at 9 V ac) °C 65 5 Series 25 Coil features Technical features Technical • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 10.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Steel Keeper: Stainless Steel • New hold-open system • Guaranteed 3 years • Complies with 2004/108/CE (EN 55014) • Corrosion resistant according to UNI ISO 9227 High-security electric strikes are considered one of the smallest and still strikes are considered one of the High-security electric market, the perfect strikes on the strongest solution for installations where high-performances are required. The radial keeper. and feature an adjustable They are 100% reversible the installer so strike, electric the of box mechanism the inside rotates keeper make it fit. does not have to cut the door frame to to prevent protection electronic with equipped are models All they are connected to. This also damage to the access control system as the connection is not polarized. represents an advantage for the installer voltages, these strikes quickly unlock Featuring a wide variety of functions and standard doors through low power consumption. 8/14 V ac/dc (14 Ω 0,7A at 12 V ac) HIGH-SECURITY B Minutes (at 12 V ac) °C 60 22 JANUARY 2012 ISSUE JANUARY Electric strikes References andfeatures 92 66 61 SHORT Recommended Faceplates Inox Inox Inox Monitoring features: C63 71 67 63 43 LONG Microswitch S3 Inox Inox Inox Inox Inox Fail-secure with monitoring Fail-safe with monitoring Fail-secure Fail-safe Hold-open ANGLED 50 49 48 45 17 16 Inox Inox Brown Brown Brown Brown keeper adjustable Radial Intensity Life Expectancy* Protection degree Humidity Ambient Temperature Insulation Resistance Contact Resistance Operating Frequency Operating Speed 6

12,75 44,5 12,75 13 20,5 Reversible Keeper’s adjustability: 3mm

Side-load 28,5 52,3 Dimensions Electrical: 100.000operationsminimum(20perminute) Mechanical: 1.000.000operationsminimum(30perminute) IEC IP67(excludingtheterminal) 95% RHmaximum(5°to35°C) From -40°Cto85°C(withoutice) 100 MΩminimum(at500VDC) 100 mΩmaximum Electrical: 30operationsperminute 1 at500mm/second(atpinplunger) 2A/12V DC 0,1A/125V AC

70 protection Electronic

21,45 44,5 12,75 29,5 20,5 with monitoring 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc 5-12 Vac/dc 8-14 Vac/dc Voltage 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc *at maximumpowerconditions

254.1.00.F 254.1.00.E 258.1.00.F 258.1.00.E 252.1.00.J 252.1.00.B 250.1.00.F 250.1.00.E 250.1.00.J 250.1.00.B 256.1.00.F 256.1.00.E 256.1.00.J 256.1.00.B References add faceplate 28,5

JANUARY 2012ISSUE 52,3

78,7 23

Electric strikes 5 12 V dc 100% (54 Ω 0,22A) P Hours °C 57 5 FAIL-SAFE FAIL-SECURE Personalized coils upon request 24 Vdc 100% (240 Ω 0,10A) N Hours °C 66 56 5 FAIL-SAFE FAIL-SECURE 12 Vdc 100% (70 Ω 0,17A) M Hours °C 51 62 5 Series 24R & 24L Series 24R & Coil features Certifications • UNE EN 1634-1, RF-120 Technical features Technical • Max. side-load on AC: 160 N Max. side-load on DC: 10 N • Break-in resistance: 10.000 N /+40 ºC • Operating temperature range: -15 ºC • Housing: Steel Keeper: Steel • Guaranteed 3 years 55014) • Complies with 2004/108/CE (EN • Corrosion resistant according to UNI ISO 9227 RF-120 electric strikes are manufactured to resist temperatures above 1.100 °C are manufactured to resist temperatures RF-120 electric strikes systems. are the ideal strikes for fire door for 120 minutes and to prevent damages with electronic protection in order DC models are equipped for the installer system. This also represents an advantage to your access control as the connection is not polarized. doors and featuring a wide variety Manufactured for left and right DIN opening quickly unlock fire doors through low of functions and voltages, these strikes power consumption. FIRE 8/14 V ac/dc (20 Ω 0,5A at 12 V ac) L Minutes (at 12 V ac) °C 62 24 JANUARY 2012 ISSUE JANUARY Electric strikes References andfeatures Recommended Faceplates 66 61 SHORT Monitoring features: Inox Inox with monitoring Fail-secure Fail-safe with monitoring Fail-safe Fail-secure Microswitch S1 71 67 43 LONG Inox Inox Inox Life Expectancy* Humidity Ambient Temperature Insulation Resistance Contact Resistance Operating Frequency Operating Speed Intensity keeper Fixed 9,48 13 Side-load

106,4 Electrical: 30.000operationsminimum Mechanical: 300.000operationsminimum 85% RHmaximum(5°to35°C) From -25°Cto65°C(withoutice) 100 MΩminimum(at500VDC) 50 mΩmaximum Electrical: 30operationsperminute Mechanical: 200operationsperminute 1 at500mm/second(atpinplunger) 0,5A/30V DC 1A/125V AC protection Electronic

29,5 52 Dimensions 8-14 Vac/dc 8-14 Vac/dc Voltage 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc

add faceplate DIN right References

24R4.4.00.N 24R4.4.00.P 24R6.4.00.N 24R6.4.00.M 24R6.4.00.L 24R8.4.00.N 24R8.4.00.P 24R0.4.00.N 24R0.4.00.M 24R0.4.00.L 20,2

17,3 48 41,1 *at maximumpowerconditions add faceplate DIN left References 24L4.4.00.N 24L6.4.00.N 24L6.4.00.M 24L6.4.00.L 24L8.4.00.N 24L0.4.00.N 24L0.4.00.M 24L0.4.00.L 24L4.4.00.P 24L8.4.00.P JANUARY 2012ISSUE 25

Electric strikes ARMOURED EMERGENCY FIRE WATERPROOF HIGH SECURITY SECURITY MINI SYMMETRIC BASIC DIN Right DIN Left Reversible Brass

Black Black Black Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Inox Grey Grey Grey Grey Inox Inox Inox Inox Inox Inox Inox Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Chrome| Color Grey|Brown Grey|Brown Grey|Brown Grey|Brown Grey|Brown Grey|

D4 D3 75 68 70 74 25 43 71 73 45 48 49 50 20 21 22 23 26 29 30 08 09 10 11 12 14 15 16 17 24 80 84 C83 (6 unit accessory for boxes 83/85) 13 62 92 82 60 03 01 69 63 64 65 67 04 05 66 76 81 02 27 28 61 C63 C64 C65 83 + C83 Faceplate 85 + Base + C83 FACEPLATES NEW NEW Boxes Type Short Long Angled 26 JANUARY 2012 ISSUE JANUARY Electric strikes

SHORT 01 3 61 Reversible 65,5 44 49,5 GREY 3mm INOX 25

52 159 66 90,5 44 65,5 Reversible

25 3mm INOX

52 3 200 02 62 30,75 48,5 30,75 Reversible

25 GREY 3mm INOX

44

52 3

110 3 76 41 45,5 73,5 Reversible

25 3mm INOX

160 27 Reversible 40,85 48,3 40,85 22

3mm INOX 3

52,3 130

43 44 43 3 92 Reversible

24 3mm INOX

52 3 28

130 Reversible 40,85 44,5 40,85 22 3mm INOX

52,3 130 JANUARY 2012ISSUE 27

Electric strikes

47,8

145 52 42,7

36,5 GREY CHROME BRASS Reversible C83 6 units included Reversible 84

BLACK + BASE + C83 25 27,35

160 box 83/85 Shim kit for 106,9

85 48

43

2

160

52 47,8

42,7

36 GREY BLACK + C83 Reversible for box 85 Metal base Reversible

81

25,5

83

47,5

26,6

160

23

104,5

47,8

104

52 44

3 44 GREY BLACK

Nylon cover 48,5 Reversible Reversible

82 80 44

22,75 48,5 32,75 160 BOXES 28 JANUARY 2012 ISSUE JANUARY Electric strikes LONG 139,75 48,5 61,75 63 03 Reversible 12 25 BROWN GREY 3mm INOX

139,75 48,5 61,75 65 05

Reversible 79 35 44 3

12 25 250 BROWN GREY 3mm INOX

102 44 D3

12,5 Reversible 3 250 BROWN GREY C65

Reversible 52 3mm INOX C63

52 Reversible 3mm INOX

122 80 48 139,75 48,5 61,75 64 04 Reversible 20 DIN Right 44 17

BROWN GREY 25 3mm INOX 14 25 INOX 2mm

102 44

80 36 44 12,5

3 2 250 250 D4 Reversible BROWN GREY 21 52 DIN Left 2mm INOX 52

15,04 C64 Reversible 3mm INOX JANUARY 2012ISSUE 29

Electric strikes

250

74

52,3

12 280

INOX 3mm 3

52

44,5 59 40 22 Reversible

30

3 146,5 25 INOX 3mm 13

Reversible 42 70

67

96 44 140

250

74

52,3 12

3

INOX 3mm

44,5 59 40 22

Reversible

146,5 29

4

17,8 33,3

R 10

66,5 33,2

12,1 7,8 INOX 3mm INOX 3mm

Reversible 24

26 247 227,5 3 Reversible 3

60

35

48,3 130,2 65,3

37 141,5 68,5 INOX 3mm DIN Left

6

23

44,5 33,2 250

3

52

12,1

25 24

INOX 3mm 12

70 44 Reversible

INOX 3mm

43

142 44 64

66,5 33,2

DIN Right

22 243,9 30 JANUARY 2012 ISSUE JANUARY Electric strikes 131 45,5 73,5

71 139,75 48,5 61,75 68 Reversible Reversible 12 15 12 15

3mm

INOX 25 25 3mm INOX 3

85 12 44 85 13 40,5 3

250 250

131 45,5 73,5 128 48 64 27 27 27 73 69 DIN Right Reversible

14 34 2mm INOX 31

3mm INOX O 20 O 44

90 12 4,7 40,5 3 2 240 250

52 74 141,5 37 68,5 DIN Left INOX 2mm

5,04

35 2

240 3 70

Reversible 247 3mm INOX 131 45,5 73,5 75

Reversible 6 15 25

3mm INOX

3 R 10 R 85 13 40,5

26 16

JANUARY 2012ISSUE 250 2 31

Electric strikes

250 32 25 2 BROWN DIN Left BROWN 12

DIN Left 12

32

11

44 15

79

25 35

R 10 R

35 52 79 44

2

250

35 79

52

79 35

25 44

R 10 12 32 12 BROWN BROWN DIN Right DIN Right 10

32 14

2

250

250

2 25

48,5

250 32 25 2 BROWN 12 BROWN DIN Left

12

DIN Left 32

44

44

2 13

25 09

102 12

52

R 10 R

12 102 32

250 250

250

102

12

2 52

12 102

44 44

R 10 25

32 12 12 BROWN BROWN DIN Right DIN Right 08

12

ANGLED 2

250 25 32 32 JANUARY 2012 ISSUE JANUARY Electric strikes 172 25 2

16 48,5 Reversible

BROWN 32

52 NEW

250 25 172 25 2 2 45 49 17 48,5 Reversible DIN Right BROWN BROWN 2mm INOX

14

32 32

R 10 R R 10 R

44 52 70 44 52 NEW 70 44 52 R 10 227,5

44 10 R 48

50 32 32,5 48,3 DIN Left 14 24 2 DIN Right BROWN 2mm INOX

2mm INOX

25 2 18,8 12,1 250 52,3 66,5 33,2

66,5 12,1 33,2 18,8 25 DIN Left 52,3 2mm INOX

32,5 2

JANUARY 2012ISSUE 48,3 227,5 33

Electric strikes

In order to satisfy all customers’ needs, O&C offersIn order to satisfy all locks in different a wide range of electromangetic sizes, voltages, forces. mounting and holding When the magnet is powered and the door is closed, the counterplate is held fast to the magnet. One must unlock counterplate is held fast to the magnet. is powered and the door is closed, the When the magnet enter and leave. the maglock to both A large electro-magnet is mounted on the door frame and the corresponding counterplate is mounted on the door. on the door. the corresponding counterplate is mounted is mounted on the door frame and A large electro-magnet Magnetic locks (commonly called maglocks) are a more and more popular choice among security installers for being security installers popular choice among a more and more maglocks) are locks (commonly called Magnetic reliable and verysimple to install, durable, resistant. ELECTROMAGNETIC LOCKS ELECTROMAGNETIC

Magnetic locks Magnetic locks

Series MEX • Guaranteed 3 years • Timer (2 to 8 seconds) • Timer • Vandal Protection • Vandal • Electronic protection • Low power consumption • Reed + LED monitoring (open/closed) Technical features Technical • Dual voltage 12/24V DC (automatic switch on selected models) Our MEX 70 is especially designed for small applications such as closets, cabinets, showcases, drawers, lockers, Our MEX 70 is especially designed for small applications such as closets, etc. Moreover, our vandal protection system secures the against tampering, theft or removal. our vandal protection system Moreover, They are available for mortise a wide range of brackets allowing an easy installation on and rim installations with any kind of doors and door frames. Basic electromagnetic locks are the perfect for emergency locking solution doors and access control systems. In open, making it safe for the occupants to exit. case of power failure, all doors will automatically BASIC 36 JANUARY 2012 ISSUE JANUARY Magnetic locks

39,5 24 65 MEX 70 47

5

5

35

24 90

3 References andfeatures 3 3W 3,3W 3,3W 32,9 force Holding 6.500 N 6.500 N 6.500 N 3.000 Nx2 3.000 Nx2 3.000 N 3.000 N 3.000 N 1.800 N

Total: 0,5kg 700 N 24 VDC(165mA) 12 VDC(340mA) 7 24 VDC(180mA) 12 VDC(270mA) 24 VDC(180mAx2) 12 VDC(270mAx2) Total: 4,4kg Total: 4,1kg

69,2 12 Vdc

MEX 700/730 265 12/24 Vdc Dual voltage Manual 35

5 20

416 MEX 600 2 3W 12/24 Vdc Dual voltage Automatic 12 VDC(250mA) Total: 1,2kg

166 MEX 100 LED Mortise

65 40

Rim 2 3,3W Timer Reed 47

+ 25

24 VDC(180mA) 12 VDC(270mA) Total: 4,5kg 2 3,3W LED

265 47

12 VDC(270mA) Total: 2,15kg

5 24

MEX 900 3 MBEX 600 MBEX 600 MBEX 300* MBEX 300* MBEX 300 MBEX 300 MBEX 180 doors opening Outward 3,3W 228 MEX 201 L 24 VDC(180mAx2) 12 VDC(270mAx2) Total: 4,4kg

315

248 MBAX 600 MBAX 600 MBAX 300* MBAX 300* MBAX 300 MBAX 300 MBAX 180 doors opening Inward MBAX 70 Z * Remember toorderoneunitforeachelectromagnetic lock! 47

MEX 630

5 482 24 MHAX 300* MHAX 300* MHAX 300 MHAX 300 MHAX 180 MHAX 70

doors Glass 3 3,3W

U 62 13,6 45,3

LED 12,6 24 VDC(180mA) 12 VDC(270mA) Total: 2,25kg

31,5 8,6 MRF 810 (optional) fire doors kit forRF Mounting LED

MEX 400/430 241

175 160 135,5 Counterplates for: References MEX 900 MEX 730 MEX 700 MEX 630 MEX 600 MEX 430 MEX 400 MEX 201 MEX 100 MEX 70 JANUARY 2012ISSUE MEX 900 MEX 700/730 MEX 600/630 MEX 400/430 MEX 201 MEX 100 LED 37

Magnetic locks

30,5

264 180

70

70 160 266 MBAX 600 (3 units) For MEX 700/730 75 70 Max. glass thickness: 16 mm MHAX 300 For MEX 400/430/600*/630* 44 Remember to order one unit for each electromagnetic lock! Remember to order one unit for each electromagnetic * 75 30,5 MBEX 600 For MEX 700/730 40 26,5

30,5 82,5 70

175

160

241

70

50 82,5 MBAX 300 (3 units) For MEX 400/430/600*/630* 190 50 57

53

MHAX 180 For MEX 100 135 34

240 8 35 Max. glass thickness: 12 mm 30,5

MBEX 300 */630* For MEX 400/430/600 45

166 136 35 MBAX 180 (3 units) For MEX 100 45

45 28 40 16 45 27

4,5

Mounting kit for fire doors MRF 810 For MEX 400/430/600*/630*

70 166 MHAX 70 For MEX 70

41 75 38 For outward opening doors. For outward For inward opening doors. For inward opening For glass doors.

40 38 L Z U MBAX 70 For MEX 70 MBEX 180 For MEX 100 BRACKETS FOR BASIC ELECTROMAGNETIC LOCKS BASIC ELECTROMAGNETIC FOR BRACKETS 35 38 38 JANUARY 2012 ISSUE JANUARY Magnetic locks For glassdoors For outwardopeningdoors and theframeneedstobeat least3mm. Please rememberthatthedistance betweentheglassdoor narrow. An “L”bracketmaybeneededwhentheframeistoo electromagnetic lockhastobeinstalledundertheframe. The counterplateisinstalleddirectlyonthedoorleaf. narrow. An “L”bracketmaybeneededwhentheframeistoo magnetic lockbeneaththeframe. The counterplateisinstalleddirectlyonthedoorand MOST COMMONINSTALLATIONS Z For inwardopeningdoors opposite sideofthehinges. The electromagneticlockhastobeinstalledontheframe, interior doorleafdirectlytothedoor. The counterplateisinstalledona“Z”bracketmountedthe

U

L rear view rear loose. counterplate mustbe screw tootightly. The Do notfastenthe JANUARY 2012ISSUE 39

Magnetic locks

(only 30 mm), they can fit most door frames, offeringthe thinnest on the market (only 30 mm), they can fit most door at the same time a high

Series ME • Guaranteed 3 years Certification ME 500/510 * IP65 (protected against dust and water) • Electronic protection • Low power consumption • Reed monitoring (open/closed) Technical features Technical • Dual voltage 12/24V DC Also available in waterproof, the ideal solution for exterior doors and gates. Also available in waterproof, the ideal In order to certify our quality, O&C tests every the test results to mini electromagnetic lock individually and attaches In order to certify our quality, the packaging. Being monitoring. built in the activate immediately will manipulation of attempt Any verya and force holding sensitivity. high The mini electromagnetic locks can be integrated into the most sophisticated interior decorations, to satisfy our most integrated into the most sophisticated interior decorations, to satisfy our most The mini electromagnetic locks can be creative customers. MINI 40 JANUARY 2012 ISSUE JANUARY Magnetic locks force Holding 30 References andfeatures

2.800 Nx2 2.800 Nx2 2.800 Nx2 2.500 N 2.500 N 2.800 N 2.800 N 2.800 N 2.800 N 2.800 N 2.800 N 2.800 N 31,5 IP65 6W 6W 6W 24 VDC(250mA) 12 VDC(500mA) 12/24 Vdc Dual voltage Total: 1,55kg Total: 1,78kg Total: 1,74kg 24 VDC(250mA) 12 VDC(500mA) 24 VDC(250mA) 12 VDC(500mA) WATERPROOF

265 265 202 Mortise

249

202 bracket included 202 ME-400/410/420 Rim MBE 800 ME-500/510 ME-200/210 LED Monitoring

40 26

10 30

LED 31

1.100 to 1.200 mm 35 MBA 806/808 MBA 806/808 doors opening Outward MBE 807 MBE 807 MBE 807 MBE 806 MBE 806 MBE 806 L MBE 805 MBE 800 35

35

MBA 801/802* MBA 801/802* MBA 801/802* MBA 801/802 MBA 801/802 MBA 801/802 MBA 801/802 MBA 801/802

12 31 doors opening Inward Z included withME600/610/620 included withME400/410/420 6W 6W “Z” installation 24 VDC(250mAx2) 12 VDC(500mAx2) 24 VDC(250mA) 12 VDC(500mA) Total: 3,48kg Total: 1,55kg

185 MHA 804* MHA 804* MHA 804* MHA 804 MHA 804 MHA 804 doors Glass U

165 Counterplate mountingkitincluded

202 FSC 821 for (optional): Bracket cover L * Remember toorderoneunitforeachelectromagnetic lock! 239

530 FSC 822 Z

35 12 bracket included ME-600/610/620 LED (optional) fire doors kit forRF Mounting MRF 810 MBE 805

ME-201/211 26 LED 30 “L” installation

185 MSA 803 (optional) doors sliding kit for Mounting

165 References ME 620 ME 610 ME 600 ME 510 ME 500 ME 420 ME 410 ME 400 ME 211 ME 210 ME 201 ME 200 JANUARY 2012ISSUE IP 65 IP 65 41

Magnetic locks

39 265

26 MBE 808 For ME 500/510

35 MSA 803 For ME 200/201/210/211 30

FSC 822 For MBA 801/802 270 Remember to order one unit for each electromagnetic lock! Remember to order one unit for each electromagnetic For glass doors. * Glass thickness: 8 to14 mm MHA 804 For ME 400/410/420/600*/610*/620* U

Mounting kit for sliding doors 525 Bracket cover MBE 807 (adjustable) * For ME 600*/610*/620 FSC 821 For MBE 806/807

26,5

50 82,5 70 175

50

70 82,5

190 270 Mounting kit for fire door MRF 810 For ME 400/410/420/600*/610*/620* 8

35 265 50

50 For outward opening doors. For outward For inward opening doors. MBA 801/802 */620* For ME 400/410/420/500/510/600*/610 50 L Z BRACKETS FOR MINI ELECTROMAGNETIC LOCKS MINI ELECTROMAGNETIC FOR BRACKETS MBE 806 (adjustable) For ME 400/410/420/500/510

50 50 42 JANUARY 2012 ISSUE JANUARY Magnetic locks For glassdoors For outwardopeningdoors and theframeneedstobeat least3mm. Please rememberthatthedistancebetweenglassdoor narrow. An “L”bracketmaybeneededwhentheframeistoo electromagnetic lockhastobeinstalledundertheframe. The counterplateisinstalleddirectlyonthedoorleaf. narrow. An “L”bracketmaybeneededwhentheframeistoo magnetic lockbeneaththeframe. The counterplateisinstalleddirectlyonthedoorand MOST COMMONINSTALLATIONS Z For inwardopeningdoors opposite sideofthehinges. The electromagneticlockhastobeinstalledontheframe, interior doorleafdirectlytothedoor. The counterplateisinstalledona“Z”bracketmountedthe U

L rear view rear loose. counterplate mustbe screw tootightly. The Do notfastenthe JANUARY 2012ISSUE 43

Magnetic locks 3 1 0 3 4 5 3 (closes all exit doors at once doors all exit (closes public buildings hospitals, schools, nursing homes,

Series DH • Low power consumption Certifications • Complies with UNE-EN 1155:2003 • Manual release button • Ejector pin to overcome residual magnetism • Jumper for voltage switch (on DHB) Technical features Technical • 600 N holding force Wall or floor supports available. Wall Typical installations are: installations Typical for needed is doors of closing instant the wherever release, manual by operated be also can holders door Magnetic safety or convenience. Designed to be used on self-closing swinging doors to automatically isolate an area when activated by fire alarm,fire by activated area when an isolate to automatically doors swinging self-closing on used be to Designed smoke detection or sprinkler systems. by push button control) and offices pushing a button on your desk). (instant privacy by DOOR HOLDER DOOR 44 JANUARY 2012 ISSUE JANUARY Magnetic locks References andfeatures 24 Vdc Voltage 2W 2W 60 12/24 Vdc Dual voltage Manual

24 VDC(85mA)

24 VDC(85mA)

247,3 DHI

DHS 200

24,7 28 Accessories &Spares 300 N/600N 50 FORCE HOLDING

50 600 N 600 N 600 N 600 N

55 55 (included) AHI (included) 7

AHS 15 Timer 3sec. button release Manual PDH

90 80 90

2W 42,5 50 mm 50 mm 50 mm 50 mm 50 mm Block

DFS 160 83 24 VDC(85mA) 24 VDC(85mA) 24 VDC(85mA) 12 VDC(170mA)

DHD DHT DHB

47,3 39 AHS -CounterplateforDHS AHI -CounterplateforDHI ADH -CounterplateforDHB/DHTDHD PDH -ManualReleaseButton DFS 300-Doorholdersupport DFS 160-Doorholdersupport DHD -Doorholderwithpower-regulation DHT -Doorholderwithtimer DHB -Dualvoltagedoorholder DHS -Basicdoorholder DHI -Industrialdoorholder 83

50 160 4

References

55 80 90

DFS 300 83 (included) 51

ADH 39 65 JANUARY 2012ISSUE 300 4 45

Magnetic locks

• Guaranteed 3 years • Auxiliary relay: max. 1A at 24V DC • Consumption at 12V DC: 2A (start up) then 0,5A (operating) • Operating temperature: from -14 to +40 ºC • Power from 10 to 36V DC (automatic switch) • 3 colours LED indicator (opened/closed/malfunction) • Maximum distance between parts: 3 mm Minimum distance between glasses: 6,5 mm • Timer: adjustable from 0 to 25 seconds for both locking (T1) and unlocking (T2) adjustable from 0 to 25 seconds for • Timer: • Electronic protection • 15.000 N holding force Technical features Technical A thief tries to escape through an emergency door where a panic bar and a shearlock are installed. When the thief door where a panic bar and a shearlock are installed. When the A thief tries to escape through an emergency be locked by the shearlock for the programmed time, and a warning the door will still signal will pushes the panic bar, the system is equipped with an acoustic alarm, If it will be ringing for the time the control center. be sent to the store’s thief to drop the goods. shearlock is programmed to, forcing the Example of use: . They combine magnetic and mechanical and magnetic combine They doors. and sliding swing for glass, solution ideal the are Shearlocks Shearlocks can be timed and connected to fire detectors, alarms,force generating a massive holding force. access a etc. If a locking defect happens after 5 attempts, the shearlock emits control systems, emergency exit buttons, warning sound until the system is reset. Series SH SHEARLOCK 46 JANUARY 2012 ISSUE JANUARY Magnetic locks References andfeatures Installation example (glass/glass installation)

SHEARLOCK SH100

SHEARLOCK SH300 220

(rim installation) 220 Keypad Locking-relay adjustment Release-relay adjustment LED (opened/closed/malfunction) 46,5027,5

38 14 Power supply 38 thickness glass Maximum (rim/glass installation)

SHEARLOCK SH400 30 Emergency strikewithmonitoring Heat orSmokedetectors

(mortise installation) (mortise

SHEARLOCK SH200 144 Acoustic warning device Acoustic warning 266 Indicator light (mortise/glass installation) (mortise/glass Push button

SHEARLOCK SH500 92

JANUARY 2012ISSUE 35 34 47

Magnetic locks

LOCKS ELECTRIC An electric lock is a locking devide which operates An electric lock is a locking devide locks are usually by means of electric current. Electric connected to an access control system. The advantges access control to an of an electric lock connected added be can keys where control, key include: system and removed without re-keying the lock cylinder; fine access control, where time and place are factors; and transaction logging, where activity is recorded. A lock is a mechanical or electronic fastening device A lock is a mechanical or electronic fastening (such as a key, that is released by a physical object token) or keycard, fingerprint, RFID card, or security informationsecret password), or a keycode (such as or combination of both.

Electric Locks 7,8W 12 VDC(650mA) 0,130 kg MINI ELECTRICBOLT

Reversible Bolt 10 Series PGX 3 yearsguarantee. Operating temperaturefrom-20ºCto+40ºC. 360º reversible. is latch its and mortise or rim either installed be can It drawers,etc. applications such as lockers,closets,showcases, This smallfail-securelockhasbeenespeciallydesignedfor 11,5

10

PGX 03 54

23,4

41,4 27,8 JANUARY 2012ISSUE 49

Electric Locks CE 104 CE 105 CE 106 CE 109 VCX 100 References CE - 109 WITH KEYS Knob Switch button Protecting visor Protecting VCX 100 Push button Keys 500mA Consumption CE - 106 WITH KNOB Acoustic alarm Magnetic sensor Timer 2 to 8s CE - 105 Voltage 12V DC

55

WITH SWITCH-BUTTON (permanent unlocking) 129,5

RIMTOPLOCK

CE - 104 126

Series CE RIMTOPLOCK Access from the outside will be granted through access control or keys (3 keys included), while from the inside one through access control or keys (3 keys included), while from the inside Access from the outside will be granted doors, aluminum or wooden interior on installed usually is It keys. and button push switch, knob, among choose can installations. but a protecting visor is available for outdoor reversible rim-mounted electric locks with a motorized bolt. When the magnetic Rimtoplocks are reversible rim-mounted electric After the scheduled sensor confirms bolt will automatically lock the door. the door is aligned with the frame, the 25mm be the door back. The distance between the lock and the counterplate should releasing time, the Rimtoplock will lock 5mm. An acoustic warning closed. will beep if the door is not properly

41 WITH PUSH-BUTTON 100 (temporary unlocking) 50 JANUARY 2012 ISSUE JANUARY Electric Locks 150 ELECTRIC BOLT BASIC BASIC ELECTRICBOLT

Series OC can besetafter0to9secondsthroughtheinbuilttimer. A LEDindicatorwill show thestatusoflock(opened/closed). The auto-lock function The gapbetweenthelockbodyandplateshouldbelessthan8mm. and120mAinstand-by.It operateson12VDCanduses300mAduringstart-up through a16mmsteelboltwhichisactivatedbysolenoid. This 34

compact easy-to-installlock(only24mmthick)securesthedoor 3 OC 860 Mortise OC 880

Rim 16

fail-secure 25 100 fail-safe

150 Mortise 34 24 Maximum glass thickness:12mm Rim Glass For glassdoors

25

40

Timer OC 890 OC 870 Mortise 3 192

bolt Round 25

100 References 12 OC 890 OC 880 OC 870 OC 860 37 JANUARY 2012ISSUE 51

Electric Locks

OPENERS & CLOSERS carries a complete line of OPENERS & CLOSERS including indicator lights, access control accessories, more. keypads, push-buttons and contacts, door loops, Along with locks and strikes, other pieces of equipment Along with locks and are necessary to complete an access control system. ACCESSORIES

Accessories

Electrical featuresanddimensions arewhite. plastic parts on sliding doors. Itsfourbrasspoles are silver-plated and the connectionand The DDC004contactisidealforpermanent white. canbe either blackor nickel-plated andtheplasticparts Itstwobrasspolesare where theconnectionisintermittent. The DDC 002 contact is suggested for simple installations are. mountedwhere thehinges frame). Theyneedtobemortise the power supply hidden electricconnectionbetweenthelockand Our high-qualitydoorcontactsaredesignedtoprovide Series DDC CONTACTS ELECTRIC 11

Max. switchingcurrent1,5A Max. switchingvoltage24VAC/DC 6 (basically fromthedoorto DDC 002

58 13

70

17,2

54 4,8 Max. switchingcurrent0,5A Max. switchingvoltage24VAC/DC

20 DDC 004 70 86 JANUARY 2012ISSUE 53

Accessories rim rim TLX 001 TLP 002 TLB 001 TLB 002 References TLP 002 TLB 002 with push button (NO) rim installation mortise mortise with push button (NO) and acoustic warning

mortise installation 40 Acoustic warning rim rim

Push button 14 22 110 TLB 001 TLX 001 2 Bulbs with acoustic warning with acoustic warning Red and Green Red and Green Red and Green Red and Green mortise mortise

18,6 OPENERS & CLOSERS’ indicator lights combine design, robustness and indicator lights combine design, OPENERS & CLOSERS’ all hearing- or visually-impaired- making them ideal for functionality, friendly installations. internalThe warningthe audible allows jumper to operate the LEDs and their connection is not operate on 10 to 24V AC/DC and They intermittently. be either mortisedpolarized. They can the or rim mounted, by simply adding included plastic box. Guaranteed 3 years. Series TL 129,5 INDICATOR LIGHTS INDICATOR with jumper The audible warning device and the LED light remains in flashing mode. The audible warning device and the LED light remains in steady mode. without jumper 54 JANUARY 2012 ISSUE JANUARY Accessories O 24,5 O EFX 290 20 16,5 RTFX DOOR LOOPS Series FX and mountings. ahighqualitysteelfinish andareavailableinseverallengths Our doorloopsoffer connection ofpowerfrom thewalltodoor(onhingesside). Door loops are required when installing an electric lock on the door. They secure the 290

24,5 Rim Mortise 16 EFX 510 18

24,5 510 diameter External 14,5 mm 14,5 mm 14,5 mm 14,5 mm 14,5 mm 14,5 mm 14,5 mm 14,5 mm 14,5 mm

SFX 150 17,4 diameter Internal 10,5 mm 10,5 mm 10,5 mm 10,5 mm 10,5 mm 150 10 mm 10 mm 10 mm 10 mm 250 SFX 370 color Finish Steel flextube Brass box Steel flextube Brass box Steel flextube Grey box Steel flextube Grey box Nickel Nickel Nickel Nickel Nickel Round terminalsforEFX290/510 370 470 lenght Flex tube 500 mm 300 mm 500 mm 300 mm 500 mm 370 mm 150 mm 370 mm 150 mm SFX 500 500 Total lenght 640 mm 440 mm 640 mm 440 mm 600 mm 470 mm 250 mm 510 mm 290 mm 600 BFX 300B BFX 300G 300 References BFX 300G BFX 500B BFX 500G BFX 300B SFX 370 SFX 150 EFX 510 EFX 290 SFX 500 RTFX 440 47

BFX 500B BFX 500G 22

500 39 640 JANUARY 2012ISSUE 55

Accessories 125 80 access control of one or control access 33 - Activates the lock for a preset time. - Activates the lock until re-entering the code. - Activates the lock Series AC KEYPAD During blackouts all the to install with high level of security. easy Very data remain stored. features Technical • Anti-vandal. • Stainless steel buttons • Housing: grey painted steel 1 to 99 seconds • Timer: • Relay: 12V AC - 2A max • Up to 12 different codes • Consumption: 0,1A (start-up) 0,02 (stand-by) • Guaranteed 3 years • IP45 Certified 12 button matrix-encoded keypad for keypad matrix-encoded button 12 two doors. from only Keypad allows to open two doors OPENERS & CLOSERS one terminal, and select two opening functions: AC 100 Voltage 12V AC/DC Voltage Fastening points 56 JANUARY 2012 ISSUE JANUARY Accessories DUMMIES • 3mmadjustable • Fitsallfaceplates Technical features value electricstrikes. keep thedoorclosedduring works andpreventdeterioration(ortheft)ofhigh- keeper behindthefaceplatethatwillhouseelectricstrikelater, inorderto During constructionworks,itisrecommendedtoinstallaprovisional DUMMY KEEPER Series CSR • Mechanicalunlocking • Radialkeeper • 3mmadjustable Technical features unlock thedoorwhennoaccesscontrolsystemisinstalled. mechanically to option the gives function electric without strike door “Mini” This DUMMY STRIKE 52,3 44,7 CSR 001

12,6 5,4

12,6 CSR 511 JANUARY 2012ISSUE 57

Accessories White: Power off Blue: Power on (standby) Red: Power on (sensation) Technical features Technical • Dimensions: 88,6L x 88,6H x 27W (mm) • Output contact: NO/NC/COM • Contact rating: 3A at 28V DC Max • Operating temperature: -20 ºC / +55 ºC • Suitable Humidity: 0 - 95% (relative humidity) • Detection range: 0,1 - 10 cm • LED indicator: Technical features Technical (mm) • Dimensions: 88,6L x 88,6H x 20W • Output contact: NO/NC/COM • Current rating: 3A at 36V DC Max ºC • Operating temperature: -10 ºC / +55 humidity) • Suitable Humidity: 0 - 95% (relative • Blue LED indicator OC 806 OC 804 Infrared Sensor Button Push-Button with LED guidance

A LED light around the push button can be useful as guidance in dark environments, while an infrared sensor represents represents sensor infrared while an environments, dark in as guidance useful be push button can the around LED light A moderna more hygienic and option. quickly and safely allow door inside the building, quickly and safely steel buttons, mounted next to the door Our quality stainless the electric locking device. exit by activating / deactivating

Series OC EXIT BUTTONS EXIT 58 JANUARY 2012 ISSUE JANUARY Accessories POWER SUPPLIES system, withcompletedischargeprotection. • Doublefunction:powersupplyandbatteriescharging“online” protection • Over-heatingandshort-circuit • Operatingtemperature:0ºC/+40 • ProtectionIP20 • 3%stability Technical features backup. chargerandabattery leds, abattery withmonitoring powerboxesfeature 4 terminals Our high-efficiency voltage toapulsatingdirect(12or24VDC). alternating If itisusedtoproduceDC,arectifierconvert a lower(usually12or24VAC)voltage. the voltage fromconvert the wall outlet (usually220VAC)to to An ACpoweredunregulatedpowersupplyusuallyusesatransformer Series PS PS 901/902 ** 4 terminals for2magneticlockseach,withmonitoringleds. ** 4terminals * FinishDINrail35x7,5(DIN50022) AC current DC current 230 V50/60Hz Input voltage voltage Output 12 Vac 24 Vdc 12 Vdc 24 Vdc 12 Vdc 24 Vdc 12 Vdc PS 907/908 current Output 1,5 Aac 1,5 Adc 3 Adc 3 Adc 6 Adc 3 Adc 6 Adc 18 VA 30 W 30 W 80 W 80 W 80 W 80 W Power charge Battery Battery 24 Vdc 12 Vdc Capacity 4 Ah 7 Ah PS 905/906 References PS 908* PS 907* PS 905** PS 902* PS 903* PS 906** PS 901* PS 903 JANUARY 2012ISSUE 59

Accessories CMI 002 CMI 016 CMI 130 CMI 122 CME 045 CMB 003 References CME 045 CMB 003 CMI 122 Standards Compliance Grade 2 EN50131-2-6 Grade 2 EN50131-2-6 Grade 2 EN50131-2-6 Grade 2 EN50131-2-6 Grade 2 EN50131-2-6 Grade 2 EN50131-2-6 Ω 12 8 200V DC 500 mA 10VA R=0,1 Ω R=10 -40 ºC / +125 ºC 10 29x 7,5o mm 18x 20o mm 29 x 20o mm 56 x 16 x 5 mm 27,5 x 7,5o mm 77 x 30 x 29 mm Magnetic contact for mortise mounting on iron doors. and duration guarantees housing ABS resistent White, 2 and contact for (2 wires output 4 with Available reliability. for tamper), with changeover reed or brown colour. Magnetic contact for rim installation on non iron frames and iron frames. Only 5mm thick. A highly sensitive contact guaranteeing a minimum gap of up to 40mm. Magnetic contact with highly-resistant black polycarbonate housing for rim mounting, suitable for installation on iron frames, garage doors and roller shutters. Contact housing only 12mm thick, with armoured cable. Magnet dimensions 29 x 7,5o mm 18 x 20o mm 29 x 20o mm 29,5 x 7,5o mm 56 x 16 x 5 mm Reed dimensions 120 x 40 x 12 mm Maximum voltage Maximum current Maximum power Initial contact resistance Insulation resistance Operating temperature MTBF Number of operations 4 wires Reed Features mortisemounting Minimum gap 12 mm 12 mm 20 mm (non iron) 10 mm (iron) 20 mm (non iron) 10 mm (iron) 25 - 40 mm 30 mm Material Brass ABS Brass ABS Plastic Polycarbonate

MAGNETIC CONTACTS CMI 130 CMI 016 CMI 002 Series CM This low profile magnetic contact is for is contact magnetic profile low This even on large heavy iron frames. Its finely knurled head can be installed in a 20mm hole maximising the magnetic quality of the contact. Magnetic contact for mortise mounting, not suitable for iron frames but ideal for installation on aluminium and wood. Also available with output wires, with changeover reed and brown colour.

Brass magnetic contact designed to guarantee maximum Brass magnetic contact efficiency and duration, particularly for mortise suitable mounting on wood and non iron surfaces. with 4 output wires, 2 for N.C. contact and 2 Available for tamper. MAGNETIC CONTACTS MAGNETIC 60 JANUARY 2012 ISSUE JANUARY Accessories BARCELONA

INNOVATION, QUALITY & SERVICE

GENERAL CATALOGUE JAN 2012 ISSUE

OPENERS & CLOSERS reserves the right to modify any product to suit technical requirements and product development. Graphic representations are merely informative. O&C | C/Cortit, 10 | 08027 Barcelona | T. 93 408 05 15 | F. 93 351 31 43 | [email protected] | www.openers-closers.com