Paper Spray Ionization: the Faster Path to Mass Spec Analysis

Total Page:16

File Type:pdf, Size:1020Kb

Paper Spray Ionization: the Faster Path to Mass Spec Analysis Paper spray ionization: The faster path to mass spec analysis Save time and reduce costs through direct sample analysis of biological fluids BROUGHT TO YOU BY INDEPENDENT SCIENCE PUBLISHER IN PARTNERSHIP WITH Paper spray ionization Introduction Common concerns with using conventional chromatography-based MS include time- Contents consuming protocols, experiment backlogs, high costs per sample, equipment downtime • Detection of controlled substances for maintenance and the need for experienced in blood samples using the VeriSpray technicians. ion source with Thermo Scientific™ Using paper spray ionization such as the TSQ Altis™ MS for clinical research Thermo Scientific™ VeriSpray™ PaperSpray and forensic toxicology ion source, researchers in clinical and forensic toxicology labs with high throughput • Quantitative analysis of antifungal requirements can now perform direct Mass drugs using PaperSpray tandem Spectrometry (MS)-based analyses with mass spectrometry for clinical minimal solvent consumption and sample research preparation, thereby saving costs per test and • Robustness characterization of reducing the time involved. a quantitative whole blood assay The VeriSpray ion source solution involves using PaperSpray technology for fast, easy and direct introduction of samples clinical research to the mass spectrometer via electrospray ionization. By simply adding samples and • Combined PaperSpray and FAIMS solvent to paper cartridges and loading them technology for rapid quantification into the system, the VeriSpray ion source of immunosuppressants in whole technology minimizes time-consuming sample blood for clinical research preparation steps and offers a simplified workflow, unlike chromatography processes. • Improving limit of quantification In recent years, paper spray-MS has in clinical research by combining garnered interest in the fields of forensic PaperSpray with FAIMS technology toxicology and clinical research due to its • Analysis of Immunosuppressant robust quantitative analysis, high-throughput Drugs Directly from Whole Blood capabilities, short turnaround times and using PaperSpray Technology time-saving workflows. In this eBook, we provide case studies and proof-of-concept • Robust Quantitative Analysis of experiments that corroborate the varied EDDP by VeriSpray PaperSpray benefits of employing paper spray ionization Spectrometry methods. • Drugs of Abuse Screening and Quantification Using Minimal sample preparation PaperSpray Technology Paper spray ionization in mass spectrometry employs a “dilute and shoot” method, • Featured Products requiring minimal sample preparation • FAQ steps, such as derivatization and reducing/ removing simpler sample purification • Additional Resources processes. In a method optimized to analyze immunosuppressant drugs, 10 μl of human blood was directly spotted on sample method directly from the dried blood spots. plates, minimizing sample preparation that In another method developed for chromatography protocols would otherwise quantitative analysis of antifungal drugs, require. Cyclosporin A, Everolimus and 4 μl of serum samples spiked with internal Tacrolimus were analyzed using a 2-minute standards were spotted on the VeriSpray 2 Paper spray ionization cartridge and allowed to dry at ambient in EDDP quantitation, this time using urine temperature for 30 minutes. The drugs – samples. Upon analyzing 480 urine samples, voriconazole, itraconazole, and posaconazole researchers reported that the system runs for – were analyzed in a 2-minute protocol that extended periods of time without the need for included the extraction step, as well as the maintenance and yielded no significant loss MS analysis. in signal. Quick turnaround time for screening Improved selectivity and limits of detection and quantitation One way to circumvent the potential Researchers investigated the potential of low signal-to-noise ratio in paper spray paper spray ionization along with a triple applications is to couple it with high-field quadrupole mass spectrometer as a screening asymmetric ion mobility spectrometry (FAIMS). tool for commonly encountered drugs of A differential ion mobility technique, FAIMS abuse in a study at Indiana University–Purdue enables greater selectivity of ions entering the University Indianapolis. The sampling plate, mass spectrometer. Coupling PaperSpray with with 24 sample tips, each holding a separate FAIMS in a proof-of-concept method analyzing dried blood spot, was analyzed in minutes, the antidepressant drug, amitriptyline, offering quick turnaround times to screen reduced background interferences and drugs, an important consideration for forensic increased signal-to-noise ratio, resulting in and clinical labs. improved limits of detection. Another proof-of-concept research method, Another study quantifying immunosuppressants testing the rapid screening ability of the in human whole blood compared calibration PaperSpray technology on 19 drugs of abuse curves obtained using the PaperSpray demonstrated how the system analyzed technology with and without FAIMS. Without 480 injections with no loss in sensitivity or coupling to FAIMS, the lowest calibration reproducibility. level for two of the immunosuppressants, tacrolimus and everolimus, was excluded due High-throughput quantitative analysis: to being close to the background signal. With The short analysis times offered by paper the FAIMS interface coupled, however, the spray ionization serves as a high-throughput background signal was significantly reduced. quantitative assay, rapidly processing samples The data showed accuracy and linearity across and saving time for clinical researchers. In the measured range. a technical method for quantitative analysis A recent webinar on paper spray-MS of EDDP (2-ethylidene- 1,5-dimethyl-3,3- explores the background of paper spray diphenylpyrrolidine), an opioid metabolite, ionization in greater detail and digs deeper human whole blood samples were analyzed. into potential applications, along with Without the need for sample pre-treatment, workflows and additional examples. separation, sample clean-up or dilution, With simple workflows, faster analyses and the system maintained sensitivity, robustness reduced cost/sample, the PaperSpray ion and quantitative accuracy over all of the source technology is an excellent option for 480 samples. every clinical research and forensic toxicology Another method tested the high-throughput laboratory looking for faster, accurate, robust, capabilities of the PaperSpray-MS system and sensitive analyses. 3 Paper spray ionization TECHNICAL NOTE 65420 Detection of controlled substances in blood samples using the VeriSpray ion source with TSQ Altis MS for clinical research and forensic toxicology Authors Application benefits Greta Ren1, Nicholas Manicke1, • Quick turn-around time Cornelia Boeser2, • Reduced cost per sample, increased ease-of-use and robustness Neloni R. Wijeratne2 1Indiana University - • Six drugs of abuse analytes in single quantitative method Purdue University Indianapolis, Indianapolis, IN Goal To develop a robust, sensitive, reliable, and reproducible PaperSpray-mass 2Thermo Fisher Scientific, spectrometry workflow for detection of illicit drugs in blood for clinical San Jose, CA research and forensic toxicology using the Thermo Scientific™ TSQ Altis™ mass spectrometer connected with the Thermo Scientific™ VeriSpray™ Keywords PaperSpray system Illicit drugs, opiates, opioids, amphetamines, PS-MS/MS, Introduction TSQ Altis MS, VeriSpray PaperSpray The abuse of controlled substances is a serious ongoing problem worldwide, ion source, TraceFinder, forensic causing significant societal disruption and economic damage. One part of toxicology, benzodiazepines the overall strategy to mitigate the effects from the abuse of drugs requires high-performance methodologies for the screening and quantitation of these substances in biological matrices. Modern forensic toxicological and clinical research laboratories need simpler methods that provide higher throughput and faster analysis for the screening and quantitation of drugs of abuse. 4 Paper spray ionization PaperSpray technology combined with triple quadrupole ion source coupled to a triple quadrupole mass mass spectrometry is an ideal choice for rapid drug spectrometer as a drug screening tool for applications screening and quantitation in clinical research and in clinical research and forensic toxicology. Experiments forensic toxicology applications for two main reasons. were carried out using the VeriSpray PaperSpray ion First, studies have demonstrated that low ng/mL or source on a TSQ Altis triple-stage quadrupole mass lower detection limits are obtainable directly from blood, spectrometer. The VeriSpray system enables robust, which is sufficient for the detection of relevant drugs rapid, and automated PaperSpray analysis. Sample at target concentrations. Second, reduce the burden storage, extraction, and ionization all take place on on the laboratory by simplifying method development, VeriSpray sampling plates. Biofluids are spotted and reducing the amount of bench work and thus decreasing dried directly on the sampling plate. The plates contain time to result. Reports in the literature for screening by 24 individual PaperSpray tips, each of which analyzes PaperSpray MS include the detection of amphetamine- a separate sample (Figure 1A). Analysis of the plate is like designer drugs in oral fluid,1 agrichemicals in fruit,2 carried out automatically via the VeriSpray ion source targeted
Recommended publications
  • Direct Analysis of Hops by Leaf Spray and Paper Spray Mass Spectrometry
    Western Michigan University ScholarWorks at WMU Master's Theses Graduate College 12-2012 Direct Analysis of Hops by Leaf Spray and Paper Spray Mass Spectrometry Kari Blain Follow this and additional works at: https://scholarworks.wmich.edu/masters_theses Part of the Chemistry Commons Recommended Citation Blain, Kari, "Direct Analysis of Hops by Leaf Spray and Paper Spray Mass Spectrometry" (2012). Master's Theses. 100. https://scholarworks.wmich.edu/masters_theses/100 This Masters Thesis-Open Access is brought to you for free and open access by the Graduate College at ScholarWorks at WMU. It has been accepted for inclusion in Master's Theses by an authorized administrator of ScholarWorks at WMU. For more information, please contact [email protected]. DIRECT ANALYSIS OF HOPS BY LEAF SPRAY AND PAPER SPRAY MASS SPECTROMETRY Kari Blain, M.S. Western Michigan University, 2012 The objective of this research is to develop a new and innovative method of hops analysis, which is much faster than standard testing methods, as well as reduce the amount of consumables and solvent used. A detailed discussion on the development of an ambient ionization mass spectrometry method called paper spray (PS-MS) and leaf spray (LS-MS) mass spectrometry will be presented. This research investigates the use of PS-MS and LS-MS techniques to determine the α- and β- acids present in hops. PS-MS and LS-MS provide a fast way to analyze hops samples by delivering data as rapidly as a UV-Vis measurement while providing information similar to lengthy liquid chromatographic separations. The preliminary results shown here indicate that PS-MS could be used to determine cohumulone and α/β ratios.
    [Show full text]
  • Advances in Ionization for Mass Spectrometry † ‡ ‡ Patricia M
    Review pubs.acs.org/ac Advances in Ionization for Mass Spectrometry † ‡ ‡ Patricia M. Peacock, Wen-Jing Zhang, and Sarah Trimpin*, † First State IR, LLC, 118 Susan Drive, Hockessin, Delaware 19707, United States ‡ Department of Chemistry, Wayne State University, 5101 Cass Avenue, Detroit, Michigan 48202, United States ■ CONTENTS ■ EMERGING DEVELOPMENTS RELATED TO NEWER IONIZATION TECHNOLOGIES Scope 372 Emerging Developments Related to Newer Ioniza- A relatively new means of transferring small, large, volatile, and tion Technologies 372 nonvolatile compounds from the solid or solution state directly Electrospray-Based Ambient Ionization 375 into the gas phase as ions, falling under the general term inlet Discharge-Based Ambient Ionization 377 ionization and individually termed matrix-assisted ionization Traditional Ionization Methods for MS 381 (MAI), solvent-assisted ionization (SAI), or laserspray Technologies Using a Laser for Ionization 381 ionization inlet (LSI) if a laser is used, continues to be API Ionization 383 developed as a sensitive and robust ionization method in MS. Author Information 384 In MAI, specific small molecule matrix compounds have been Corresponding Author 384 discovered which require only exposure to subatmospheric ORCID 384 pressure conditions, by default available with all mass Notes 384 spectrometers, to produce gas-phase ions of peptides, proteins, Biographies 384 lipids, synthetic polymers, and carbohydrates for analysis by Acknowledgments 385 MS.16 Some MAI matrixes produce abundant ions without the References 385 need to apply thermal energy. Out of over 40 such matrixes, the top 10 have been categorized for positive and negative mode measurements. These matrixes sublime when placed under subatmospheric pressure so that, similar to solvents, they are pumped from the mass spectrometer eliminating matrix contamination.17 Several studies related to MAI were published in this period ■ SCOPE by Trimpin and collaborators.
    [Show full text]
  • 1 Introduction of Mass Spectrometry and Ambient Ionization Techniques
    1 1 Introduction of Mass Spectrometry and Ambient Ionization Techniques Yiyang Dong, Jiahui Liu, and Tianyang Guo College of Life Science & Technology, Beijing University of Chemical Technology, No. 15 Beisanhuan East Road, Chaoyang District, Beijing, 100029, China 1.1 Evolution of Analytical Chemistry and Its Challenges in the Twenty-First Century The Chemical Revolution began in the eighteenth century, with the work of French chemist Antoine Lavoisier (1743–1794) representing a fundamental watershed that separated the “modern chemistry” era from the “protochemistry” era (Figure 1.1). However, analytical chemistry, a subdiscipline of chemistry, is an ancient science and its metrological tools, basic applications, and analytical processes can be dated back to early recorded history [1]. In chronological spans covering ancient times, the middle ages, the era of the nineteenth century, and the three chemical revolutionary periods, analytical chemistry has successfully evolved from the verge of the nineteenth century to modern and contemporary times, characterized by its versatile traits and unprecedented challenges in the twenty-first century. Historically, analytical chemistry can be termed as the mother of chemistry, as the nature and the composition of materials are always needed to be iden- tified first for specific utilizations subsequently; therefore, the development of analytical chemistry has always been ahead of general chemistry [2]. During pre-Hellenistic times when chemistry did not exist as a science, various ana- lytical processes, for example, qualitative touchstone method and quantitative fire-assay or cupellation scheme have been in existence as routine quality control measures for the purpose of noble goods authentication and anti-counterfeiting practices. Because of the unavailability of archeological clues for origin tracing, the chemical balance and the weights, as stated in the earliest documents ever found, was supposed to have been used only by the Gods [3].
    [Show full text]
  • An Ambient Detection System for Visualization of Charged Particles Generated with Ionization Methods at Atmospheric Pressure
    An ambient detection system for visualization of charged particles generated with ionization methods at atmospheric pressure Bob Hommersom1,2, Sarfaraz U. A. H. Syed1,4, Gert B. Eijkel1,2, David P. A. Kilgour3, David R. Goodlett3,5 and Ron M. A. Heeren1,2,4* 1FOM Institute AMOLF, Science Park 104, 1098 XG Amsterdam, The Netherlands 2M4I, The Maastricht MultiModal Molecular Imaging Institute, University of Maastricht, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands 3University of Maryland School of Pharmacy, 20 N Pine Street, Baltimore, Maryland 21201, USA 4Amsterdam Scientific Instruments B.V., Science Park 105, 1098 XG Amsterdam, The Netherlands 5Deurion LLC, 3518 Fremont Avenue #503, Seatle, WA 98103, USA RATIONALE: With the current state-of-the-art detection of ions only taking place under vacuum conditions, active pixel detectors that operate under ambient conditions are of particular interest. These detectors are ideally suited to study and characterize the charge distributions generated by ambient ionization sources. METHODS: The direct imaging capabilities of the active pixel detector are used to investigate the spatial distributions of charged droplets generated by three ionization sources, named electrospray ionization (ESI), paper spray ionization (PSI) and surface acoustic wave nebulization (SAWN). The ionization spray (ESI/PSI) and ionization plume (SAWN) originating from each source are directly imaged. The effect of source parameters such as spray voltage for ESI and PSI, and the angle of the paper spray tip on the charge distributions, is investigated. Two types of SAWN liquid interface, progressive wave (PW) and standing wave (SW), are studied. RESULTS: Direct charge detection under ambient conditions is demonstrated using an active pixel detector.
    [Show full text]
  • Capturing Fleeting Intermediates in a Catalytic C–H Amination Reaction Cycle
    Capturing fleeting intermediates in a catalytic C–H amination reaction cycle Richard H. Perry1, Thomas J. Cahill III1, Jennifer L. Roizen, Justin Du Bois2, and Richard N. Zare2 Department of Chemistry, Stanford University, Stanford, CA 94305-5080 Edited* by Robert G. Bergman, University of California, Berkeley, CA, and approved September 21, 2012 (received for review May 4, 2012) We have applied an ambient ionization technique, desorption impacts a surface containing a sample of interest and extracts electrospray ionization MS, to identify transient reactive species analyte into secondary microdroplets. Subsequent desolvation of an archetypal C–H amination reaction catalyzed by a dirhodium generates gas-phase ions that can be mass analyzed (16–21). By tetracarboxylate complex. Using this analytical method, we have coupling DESI to a high-resolution Orbitrap mass spectrometer detected previously proposed short-lived reaction intermediates, (23, 24), we are able to detect transient species with high mass including two nitrenoid complexes that differ in oxidation state. accuracy (1 to 5 ppm). In this study, we performed C–Hami- Our findings suggest that an Rh-nitrene oxidant can react with hy- nation experiments by spraying a solution of the sulfamate drocarbon substrates through a hydrogen atom abstraction pathway ester 2 (ROSO2NH2;R= CH2CCl3) and iodine(III) oxidant 3 – and raise the intriguing possibility that two catalytic C H amination at Rh2(esp)2 1 or a mixture of 1 and a hydrocarbon substrate pathways may be operative in a typical bulk solution reaction. As (adamantane) deposited on a paper surface (Fig. 2). This analyt- highlighted by these results, desorption electrospray ionization ical method (20–22, 25–28) provides direct evidence for Rh- MS should have broad applicability for the mechanistic study of nitrene formation and the ability of this two-electron oxidant to catalytic processes.
    [Show full text]
  • Early Detection of Unilateral Ureteral Obstruction by Desorption
    www.nature.com/scientificreports OPEN Early detection of unilateral ureteral obstruction by desorption electrospray ionization mass Received: 13 May 2019 Accepted: 16 July 2019 spectrometry Published: xx xx xxxx Shibdas Banerjee1,2, Anny Chuu-Yun Wong3, Xin Yan1, Bo Wu3, Hongjuan Zhao3, Robert J. Tibshirani4, Richard N. Zare1 & James D. Brooks 3 Desorption electrospray ionization mass spectrometry (DESI-MS) is an emerging analytical tool for rapid in situ assessment of metabolomic profles on tissue sections without tissue pretreatment or labeling. We applied DESI-MS to identify candidate metabolic biomarkers associated with kidney injury at the early stage. DESI-MS was performed on sections of kidneys from 80 mice over a time course following unilateral ureteral obstruction (UUO) and compared to sham controls. A predictive model of renal damage was constructed using the LASSO (least absolute shrinkage and selection operator) method. Levels of lipid and small metabolites were signifcantly altered and glycerophospholipids comprised a signifcant fraction of altered species. These changes correlate with altered expression of lipid metabolic genes, with most genes showing decreased expression. However, rapid upregulation of PG(22:6/22:6) level appeared to be a hitherto unknown feature of the metabolic shift observed in UUO. Using LASSO and SAM (signifcance analysis of microarrays), we identifed a set of well-measured metabolites that accurately predicted UUO-induced renal damage that was detectable by 12 h after UUO, prior to apparent histological changes. Thus, DESI-MS could serve as a useful adjunct to histology in identifying renal damage and demonstrates early and broad changes in membrane associated lipids. Renal biopsy is used commonly to assess the etiology of renal failure, where it has been reported to alter clinical management in approximately 40% of all patients and up to 70% of cases with acute kidney injury1,2.
    [Show full text]
  • Accelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments
    PC71CH02_Cooks ARjats.cls April 9, 2020 11:29 Annual Review of Physical Chemistry Accelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments Zhenwei Wei,1 Yangjie Li,1 R. Graham Cooks,1 and Xin Yan2 1Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, USA; email: [email protected] 2Department of Chemistry, Texas A&M University, College Station, Texas 77842, USA; email: [email protected] Annu. Rev. Phys. Chem. 2020. 71:31–51 Keywords The Annual Review of Physical Chemistry is online at reaction acceleration, interfacial reactions, ion solvation, electrospray Annu. Rev. Phys. Chem. 2020.71:31-51. Downloaded from www.annualreviews.org physchem.annualreviews.org Access provided by Radboud Universiteit Nijmegen on 04/15/21. For personal use only. ionization, mass spectrometry https://doi.org/10.1146/annurev-physchem-121319- 110654 Abstract Copyright © 2020 by Annual Reviews. Various organic reactions, including important synthetic reactions involving All rights reserved C–C, C–N, and C–O bond formation as well as reactions of biomolecules, are accelerated when the reagents are present in sprayed or levitated micro- droplets or in thin films. The reaction rates increase by orders of magnitude with decreasing droplet size or film thickness. The effect is associated with reactions at the solution–air interface. A key factor is partial solvation of the reagents at the interface, which reduces the critical energy for reaction. This phenomenon is of intrinsic interest and potentially of practical value as a simple, rapid method of performing small-scale synthesis. 31 PC71CH02_Cooks ARjats.cls April 9, 2020 11:29 1. INTRODUCTION: BACKGROUND AND HISTORY Mass spectrometry (MS), the art of ionization of compounds and manipulation of the resulting ions in vacuum, is widely used to measure the mass-to-charge ratios (m/z) of ionized compounds for their chemical characterization (1).
    [Show full text]
  • 1 Principles of Liquid Chromatography-Mass
    To my family [INDEX] INDEX List of publications and conference contributes V Introduction 1 CHAPTER I 1 Principles of Liquid Chromatography-Mass Spectrometry Coupling 2 1.1 Introduction 2 1.2 High Performance Liquid Chromatography (HPLC) 3 1.2.1 Chromatographic properties 5 1.3 HPLC Instrumentation 6 1.3.1 Mobile phase reservoirs 7 1.3.2 Pump system 7 1.3.3 Sample injection system 7 1.3.4 The column 8 1.3.5 Detectors 9 1.4 Mass Spectrometry: Principles and Instrumentation 9 1.4.1 Introduction 9 1.4.2 Mass spectrometer components 10 1.4.3 Ion Sources 10 1.4.3.1 Electron Ionization 11 1.4.3.2 Chemical Ionization 13 1.4.3.3 Atmospheric Pressure Chemical Ionization (APCI) 14 1.4.3.4 Electrospray Ionization (ESI) 16 1.4.3.5 Desorption Electrospray Ionization (DESI) 20 1.4.3.6 Direct Analysis in Real Time (DART) 22 1.4.3.7 Matrix-Assisted Laser Desorption Ionization (MALDI) 24 I [INDEX] 1.5 Mass Analyzers 26 1.5.1 Introduction 26 1.5.2 Linear Quadrupole (Q) Analyzers 30 1.5.3 Ion Trap Analyzers 33 1.5.4 Quadrupole Ion Traps (QIT) 33 1.5.5 Linear Ion Traps (LIT) 34 1.5.6 Time-of-Flight (TOF)Analyzers 35 1.5.6.1 Linear Time-of-Flight Analyzer 37 1.5.6.2 Delayed Pulsed Extraction 38 1.5.6.3 Reflectron Time-of-Flight Analyzers 39 1.5.7 Tandem Mass Spectrometry 41 References (Chapter I) 44 CHAPTER II 2 Recent Ambient Ionization Methods for Mass spectrometry: 50 Paper Spray and Leaf Spray 2.1 Introduction 50 2.2 Paper Spray Ionization for Mass Spectrometry (PS-MS) 52 2.3 Leaf Spray Mass Spectrometry (LS-MS) 56 References (Chapter II) 59 CHAPTER III
    [Show full text]
  • In Situ Separation and Analysis of Lipids by Paper Spray Ionization Mass Spectrometry
    molecules Communication In Situ Separation and Analysis of Lipids by Paper Spray Ionization Mass Spectrometry Youngju Kal and Sangwon Cha * Department of Chemistry, Dongguk University, Seoul 04620, Korea; [email protected] * Correspondence: [email protected]; Tel.: +82-2-2260-8907 Abstract: Paper spray ionization (PSI) is an extractive ambient ionization technique for mass spec- trometry (MS), whereby a triangular paper tip serves as the sampling base and the electrospray tip. During PSI, analytes are extracted and transported to the edge of the paper tip by the applied spraying solvent. Analytes can be purified from a sample matrix and separated from each other by this transportation process. In this study, we investigated and utilized the analyte transportation process of PSI for the in situ separation and analysis of lipid mixtures. We found that differential transport of phosphatidylcholine (PC) and triacylglycerol (TAG), the two most abundant lipid classes in animals, occurred during PSI. We also found that the order in which these lipids moved strongly depended on how the spraying solvent was applied to the paper base. The more polar PC moved faster than the less polar TAG during PSI, when a polar solvent was slowly fed into a paper tip, whereas TAG was transported faster than PC when excess solvent was applied to the tip at once. In addition, we achieved a complete separation and detection of PC and TAG by slowly supplying a nonpolar solvent to a PSI tip. Keywords: paper spray ionization; mass spectrometry; lipids; phosphatidylcholine; triacylglycerol Citation: Kal, Y.; Cha, S. In Situ 1. Introduction Separation and Analysis of Lipids by Ambient ionization methods for mass spectrometry (MS) have become immensely Paper Spray Ionization Mass popular, as their convenience and raw material analysis capabilities are unapparelled [1,2].
    [Show full text]
  • Analysis of Biofluids by Paper Spray Mass Spectrometry: Advances and Challenges
    Analysis of Biofluids by Paper Spray Mass Spectrometry: Advances and Challenges Nicholas E. Manicke, Brandon J. Bills, and Chengsen Zhang Department of Chemistry and Chemical Biology, Indiana University-Purdue University Indianapolis, Indianapolis, Indiana 46202, United States Abstract Paper spray mass spectrometry (MS) is part of a cohort of ambient ionization or direct analysis methods that seek to analyze complex samples without prior sample preparation. Extraction and electrospray ionization occur directly from the paper substrate upon which a dried matrix spot is stored. Paper spray MS is capable of detecting drugs directly from dried blood, plasma, and urine spots at the low ng/mL to pg/mL levels without sample preparation. No front end separation is performed, so tandem mass spectrometry (MS/MS) or high resolution MS is required. Here, we discuss paper spray methodology, give a comprehensive literature review of the use of paper spray MS for bioanalysis, discuss technological advancements and variations on this technique, and discuss some of its limitations. _________________________________________________________________________________ This is the author's manuscript of the article published in final edited form as: Manicke, N. E., Bills, B. J., & Zhang, C. (2016). Analysis of biofluids by paper spray MS: advances and challenges. Bioanalysis, 8(6), 589–606. https://doi.org/10.4155/bio-2015-0018 Abstract Paper spray mass spectrometry (MS) is part of a cohort of ambient ionization or direct analysis methods that seek to analyze complex samples without prior sample preparation. Extraction and electrospray ionization occur directly from the paper substrate upon which a dried matrix spot is stored. Paper spray MS is capable of detecting drugs directly from dried blood, plasma, and urine spots at the low ng/mL to pg/mL levels without sample preparation.
    [Show full text]
  • Long Abstract Paper Spray Ionization
    Long Abstract Paper Spray Ionization - Tandem Mass Spectrometry for Quantification of Prescription Drugs in Oral Fluid Karen E. Cesafsky, Valentina Pirro, Alan K. Jarmusch, and R. Graham Cooks Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN 47907 Paper Spray (PS) is an ambient ionization technique used with mass spectrometry (MS) for rapid analysis from complex matrices. Briefly, the procedure includes drying a sample onto a piece of triangular shaped paper, placing the paper in front of the MS source, wetting the paper with solvent, and applying a high voltage using a copper clip which generates ions via electrospray- like mechanisms (Fig 1). PS seeks to remove the need for complex sample preparation (e.g., SPE) as well as time consuming and expensive chromatographic separations (e.g. LC and GC), but still relies on MS for specificity, particularly enhanced with multiple stages of mass analysis (MS/MS). PS-MS/MS allows for the analysis of drugs and small molecules in biofluids, e.g. whole blood, plasma, urine and oral fluid. Applications include point of care diagnostics, roadside drug testing, pharmaceutical metabolite studies and many more. Presented here is a rapid method for the detection of prescription drugs and their metabolites in oral fluid. Experiments were performed with a Thermo Fisher Quantum Max triple quadrupole mass spectrometer. Opiates and opioids, benzodiazepines, and tranquillizers were detected in positive ion mode via multiple reaction monitoring, selecting two fragments per drug to increase the specificity of the analytical signal. Less than 10 µL of oral fluid spiked with stable isotopic internal standards was spiked onto triangular shaped filter paper.
    [Show full text]
  • MASS SPECTROMETRY: INVESTIGATION of SAMPLING DEVICES for ILLICIT DRUG DETECTION and QUANTIFICATION by Chau Bao Nguyen
    PAPER SPRAY - MASS SPECTROMETRY: INVESTIGATION OF SAMPLING DEVICES FOR ILLICIT DRUG DETECTION AND QUANTIFICATION by Chau Bao Nguyen A Thesis Submitted to the Faculty of Purdue University In Partial Fulfillment of the Requirements for the degree of Master of Science Department of Forensic and Investigative Sciences at IUPUI Indianapolis, Indiana July 2021 THE PURDUE UNIVERSITY GRADUATE SCHOOL STATEMENT OF COMMITTEE APPROVAL Dr. Nicholas E. Manicke, Chair Department of Chemistry and Chemical Biology Dr. John V. Goodpaster Department of Chemistry and Chemical Biology Dr. Frédérique T. Deiss Department of Chemistry and Chemical Biology Approved by: Dr. John V. Goodpaster 2 This thesis is dedicated to my beloved parents and my sister, who continually provide their moral, emotional, and financial support, and to my partner, who is always there for me. 3 ACKNOWLEDEGMENTS First of all, I would like to thank my supervisor, Dr. Nicholas Manicke for giving me the opportunity to carry out my graduate work in his lab. His supervisory style is a perfect balance between guidance and independence, which gives me room to learn and grow in the right direction. His knowledge, enthusiasm, and patience helped a lot in my personal and career growth. I would also like to thank my committee members, Dr. Goodpaster and Dr. Deiss for their insightful comments, helpful ideas, and informative discussion throughout my time in my master’s program. Many thanks to my lab colleagues in the Manicke group, especially Greta Ren, Christine Skaggs, Sarah Dowling, Magnus Rydberg, and Hannah Zimmerman for putting up with me and providing me with endless words of encouragement as well as countless technical and practical support when I first started.
    [Show full text]