Moomba Pipeline

Receipt and Delivery Points

Receipt Points

Name* Location Pressure (kPa) Physical Zone Capacity [see note 2] (GJ/Day)

[see note 1]

SWQP Receipt The point of Minimum: 4,600 300,000 MSP-RZ-01 Point interconnection Maximum: 5,200 between the SWQP and the MSP at Moomba

Culcairn (North) The point of Minimum: 2,800 223,000 MSP-RZ-03 Receipt Point interconnection Maximum: between 10,200 Victorian Transmission System and the MSP at Culcairn

EGP Receipt The point of Minimum: 2,800 300,000 MSP-RZ-02 Point interconnection Maximum: 6,200 between the Eastern Gas pipeline and the MSP at Wilton

Moomba Gas The point of Minimum: 6,400 120,000 MSP-RZ-01 Plant Receipt interconnection Maximum: 7,300 Point between the Moomba Gas Plant and the Moomba Interconnect Pipeline

Moomba Low A virtual point, Not Applicable Not Applicable MSP-RZ-01 Pressure Trade located in the Point suction (low pressure) header within

1

Moomba Sydney Pipeline

Receipt and Delivery Points

Name* Location Pressure (kPa) Physical Zone Capacity [see note 2] (GJ/Day)

[see note 1] APA’s Moomba Compound.

Culcairn Trade A virtual point Not Applicable Not Applicable MSP-RZ-03 Point on the MSP located adjacent to the point of interconnection between the Victorian Transmission System and the MSP at Culcairn.

Wilton Trade A virtual point Not Applicable Not Applicable MSP-RZ-02 Point on the MSP located adjacent to the point of interconnection between the MSP and the Jemena Gas Networks distribution at Wilton.

2

Moomba Sydney Pipeline

Receipt and Delivery Points

Delivery Points

Name* Location Pressure Physical Temperature Zone (kPa) Capacity (°C) [see note 2] (GJ/Day)

[see note 1]

Bargo Minimum 4,585 Minimum: 0 MSP-DZ-06 1,750 Maximum: 50 Maximum 6,200

Bathurst Minimum 8,407 Minimum: 0 MSP-DZ-04 1,750 Maximum: 50 Maximum 9,930

Blayney Minimum 1,635 Minimum: 0 MSP-DZ-04 1,750 Maximum: 50 Maximum 9,930

Boorowa Minimum 846 Minimum: 0 MSP-DZ-06 1,750 Maximum: 50 Maximum 6,200

Bowral Minimum 8,407 Minimum: 0 MSP-DZ-06 1,750 Maximum: 50 Maximum 6,200

Bulla Park Minimum 800 Minimum: 0 MSP-DZ-02 1,750 Maximum: 50 Maximum 6,200

Canberra Minimum 52,000 Minimum: 0 MSP-DZ-07 1,205 Maximum: 50 Maximum 7,800

Coolamon Minimum 9,000 Minimum: 0 MSP-DZ-05 1,750 Maximum: 50

3

Moomba Sydney Pipeline

Receipt and Delivery Points

Maximum 10,200

Cootamundr Minimum 1,635 Minimum: 0 MSP-DZ-04 a 1,750 Maximum: 50 Maximum 8,509

Cowra Minimum 1,635 Minimum: 0 MSP-DZ-04 1,750 Maximum: 50 Maximum 9,930

Culcairn The point of Minimum: 150,000 Minimum: 0 MSP-DZ-08 (South) interconnect 5,500 Maximum: 50 Delivery ion between Maximum:10, Point Victorian 200 Transmission System and the MSP at Culcairn

Dubbo (CRP) Minimum 5,300 Minimum: 0 MSP-DZ-03 1,750 Maximum: 50 Maximum 6,200

Ganmain Minimum 9,000 Minimum: 0 MSP-DZ-05 1,750 Maximum: 50 Maximum 10,200

Goulburn Minimum 8,407 Minimum: 0 MSP-DZ-06 1,750 Maximum: 50 Maximum 6,200

Griffith Minimum 9,000 Minimum: 0 MSP-DZ-05 1,750 kPa Maximum: 50 Maximum 10,200 kPa

Henty Minimum 780 Minimum: 0 MSP-DZ-08 1,750 Maximum: 50 Maximum 10,200

4

Moomba Sydney Pipeline

Receipt and Delivery Points

Holbrook Minimum 900 Minimum: 0 MSP-DZ-08 1,750 Maximum: 50 Maximum 10,200

Illabo Minimum 1,530 Minimum: 0 MSP-DZ-04 1,750 Maximum: 50 Maximum 8,509

Junee Minimum 9,000 Minimum: 0 MSP-DZ-05 1,750 Maximum: 50 Maximum 10,200

Leeton Minimum 9,000 Minimum: 0 MSP-DZ-05 1,750 Maximum: 50 Maximum 10,200

Lithgow Minimum 8,407 Minimum: 0 MSP-DZ-04 1,750 Maximum: 50 Maximum 9,930

MAPS The point of Minimum: 120,000 Minimum: 0 MSP-DZ-01 Delivery interconnect 2,000 Maximum: 50 Point ion between Maximum: the metering 6,200. and flow control facilities at the discharge of the Moomba Compressor and the MAPS.

Marsden Minimum 13,000 Minimum: 0 MSP-DZ-02 (CWP) 3,600 Maximum: 50 Maximum 6,350

Marulan Minimum 8,407 Minimum: 0 MSP-DZ-06 1,750 Maximum: 50

5

Moomba Sydney Pipeline

Receipt and Delivery Points

Maximum 6,200

Millthorpe Minimum 302 Minimum: 0 MSP-DZ-04 1,750 Maximum: 50 Maximum 9,930

Moomba The point of Maximum 120,000 Minimum: 0 MSP-DZ-01 Gas Plant interconnect 7,240 Maximum: 50 Delivery ion between Point the metering and flow control facilities at the discharge of the Moomba Compressor and the interconnect into the Moomba Gas Plant

Moss Vale Minimum 1,635 Minimum: 0 MSP-DZ-06 1,750 Maximum: 50 Maximum 6,200

Murrami Minimum 9,000 Minimum: 0 MSP-DZ-05 1,750 Maximum: 50 Maximum 10,200

Narrandera Minimum 9,000 Minimum: 0 MSP-DZ-05 1,750 Maximum: 50 Maximum 10,200

Oberon Minimum 8,407 Minimum: 0 MSP-DZ-04 1,750 Maximum: 50 Maximum 9,930

6

Moomba Sydney Pipeline

Receipt and Delivery Points

Orange Minimum 8,407 Minimum: 0 MSP-DZ-04 1,750 Maximum: 50 Maximum 9,930

Rockdale Minimum 9,000 Minimum: 0 MSP-DZ-05 1,750 Maximum: 50 Maximum 10,200

Sally’s Minimum 765 Minimum: 0 MSP-DZ-06 Corner 1,750 Maximum: 50 Maximum 6,200

Uranquinty Minimum 1,531 Minimum: 0 MSP-DZ-08 1,750 Maximum: 50 Maximum 8,509

Uranquinty Minimum 80,000 Minimum: 0 MSP-DZ-08 Power 2,800 Maximum: 50 Station Maximum 10,200

Wagga Minimum 8,407 Minimum: 0 MSP-DZ-04 Wagga 1,750 Maximum: 50 Maximum 8,509

Wallendbee Minimum 480 Minimum: 0 MSP-DZ-04 n 1,750 Maximum: 50 Maximum 8,509

Wallerawan Minimum 355 Minimum: 0 MSP-DZ-04 g 1,750 Maximum: 50 Maximum 9,930

West Minimum 1,800 Minimum: 0 MSP-DZ-02 Wyalong 1,750 Maximum: 50 Maximum 6,200

Yass/Blackne Minimum 801 Minimum: 0 MSP-DZ-06 y’s Creek 1,750 Maximum: 50

7

Moomba Sydney Pipeline

Receipt and Delivery Points

Maximum 6,200

Young Minimum 1,635 Minimum: 0 MSP-DZ-04 1,750 Maximum: 50 Maximum 8,509

Wilton STTM The point of Minimum 327,000 Minimum: 0 MSP-DZ-06 Delivery interconnect 1,750 Maximum: 50 Point ion between Maximum the MSP and 6,200

Moomba A virtual Not Not Minimum: 0 MSP-DZ-01 Low Pressure point, Applicable Applicable Maximum: 50 Trade Point located in the suction (low pressure) header within APA’s Moomba Compound.

Culcairn A virtual Not Not Minimum: 0 MSP-DZ-08 Trade Point point on the Applicable Applicable Maximum: 50 MSP located adjacent to the point of interconnect ion between the Victorian Transmission System and the MSP at Culcairn.

Wilton Trade A virtual Not Not Minimum: 0 MSP-DZ-06 Point point on the Applicable Applicable Maximum: 50 MSP located adjacent to the point of interconnect ion between the MSP and the Jemena

8

Moomba Sydney Pipeline

Receipt and Delivery Points

Gas Networks distribution at Wilton.

* A compression service at Moomba and/or Wallumbilla may be required depending on the combination of receipt points and delivery points. See matrix to determine applicable services: https://www.apa.com.au/globalassets/documents/info/tariff-docs/swqp_tariffs.pdf

Note 1: Hourly Physical Capacity unless otherwise stated is the Physical Capacity at the point divided by 24 and multiplied by the MHQ Factor for the Facility as set out in Schedule 10 of the Facility Specific Terms.

Note 2: Zones descriptions are accurate as at January 2019, however are subject to change in accordance with the National Gas Rules. The zone information published in the AEMO Transportation Service Point Register prevails in the event of an inconsistency.