1 TMS3350

TMS3350

NTP Server with The TMS3350 is rack mount equipment Remote monitoring able to provide a high stable time The remote control of the equipment source on an TCP / IP is done via the network, using: IRIGB network. The TMS3350 is a time server that uses . The SNMP standard protocol the (NTP) to (MIB provided) synchronization synchronize all connected computers . The standard SSH protocol on the network. An UDP frame containing the time NTP Server and status of the equipment is emitted NTP server stratum 1 every second. The equipment provides an NTP service in request / response mode in IRIG-B synchronisation stratum1 when it is synchronized to Oscillator one of the two possible time sources. An internal basic TCXO type oscillator HTTPS Monitoring and Control The server manages frame provides a 10 MHz frequency used to through a web based interface authentication. maintain time in case of loss of The client computers can be external time source synchronized with a precision better Secure access to the server by than 5 ms. SSH The server has the following main Configuration interfaces: The entire configuration of the equipment is contained in a Monitoring with SNMP V2c, V3 • Network connection IEEE802.3 100/1000 Mbs removable SDCARD memory for easy • Synchronous UTC pulse top pulse (1 system configuration and equipment On-site equipment update PPS) update. In case of equipment replacement, the current configuration can be simply Protected configuration on transferred by plugging the SDCARD in SDCARD IRIGB synchronization the new equipment minimizing the MTTR. The equipment synchronizes on its analog IRIG-B input. Unlimited number of client

Number of transactions > 800 / second

TM3350 Front panel

Information contained in this document is subject to changes without further notice. fp2176a1 www.timelinkmicro.com. TIMELINK MICROSYSTEMS 14 rue Jean Perrin 31100 Toulouse Tél. : +33 (0)5 62 87 10 70 2 TMS3350

Specifications

NETWORK PROTOCOLS Console MTBF A console link for equipment 100 000 h NTP (Network Time Protocol) maintenance is available on the front panel. To compensate for the NTP (RFC 1305) SNTP (RFC 1361) using rarefaction of RS232 serial interfaces Temperature UDP 123 port on PCs, the equipment allows a direct Operating temperature: -20 ° to 60 ° C Server configuration V3, V4 or connection in USB, a USB / serial Storage temperature: -20 ° to 70 ° C automatic V3/V4 converter is integrated. This USB Operating relative humidity: connection is dedicated to a serial link 10% to 90% (non-condensing) HTTPS and cannot accommodate any other Storage relative humidity: 5% to 95% (non-condensing) Advanced web interface for control type of device.

and monitoring based on Events.. On request, the Console link can be Dimensions RS232-type on a 9-pin SubD connector Rack 1U 19 "Depth 13.8 in SNMP (Simple Network or removed. Management Protocol) Power Supply Weight (RFC 1155, 1157, 1213) V2c, V3 < 6.61 lb including the power cable SNMP provides to the network The equipment is powered by the administrator the equipment status. main 230V via two redundant power For security reasons no configuration supplies for better reliability Certification changes can be made with this Power supply range 85 to 260VAC at Certified CE, ROHS and ITAR Free protocol. 40-60 Hz Power consumption: 30 W SSH () Option

SSH allows accessing securely the Ruggedized rack

equipment. Redundant Power Supply It's especially used to update the OCXO stability internal software of the equipment.

Connectors 1 x BNC for the IRIGB input 1 x BNC output for 1PPS 2 x RJ45 network connection

Network Interface IEEE 802.3. 10/100/1000 Ethernet

TMS3350 Back panel

Ordering code TMS3350: standard model

Information contained in this document is subject to changes without further notice. fp2176a1 www.timelinkmicro.com. TIMELINK MICROSYSTEMS 14 rue Jean Perrin 31100 Toulouse Tél. : +33 (0)5 62 87 10 70