Confocal Application Notes Vol

Total Page:16

File Type:pdf, Size:1020Kb

Confocal Application Notes Vol Confocal Application Notes Vol. 3 January 2005 On Resolution, Pixels, Zoom and Scan Format 1. Optical resolution of the objective The theoretical lateral optical resolution in wide field microscopy is given as: rxy = 0.61 * λ N .A. (Rayleigh criteria) Due to the narrower point spread function of the confocal microscope, lateral resolution is improved and one can use: rxy = 0.4*λ N.A. For example, a 40x objective with a N.A. of 1.25 will have a theoretical xy- resolution of 156.2 nm at 488 nm. rxy = 0.4* 488nm 1.25 rxy = 156.2nm This 40x/1.25 N.A. objective will be used as an example for this note. 2. Scan Format and Scan Field Size The scan format determines how many lines are scanned and how many samples are taken along each scan line. The scan format is expressed as: Number of pixels per line x Lines per frame. A scan format of 512x512 therefore means that the sample area is scanned at a resolution of 512x512 pixels. For a given microscope, the size of the scan field (the x-y dimensions of your image) itself is determined by the objective magnification and the zoom factor used (we will talk about zoom later). Leica Microsystems Inc. Telephone (610)-321-0460 410 Eagleview Blvd, Ste. 107 Toll Free 866-830-0735 Exton, PA 19341 Fax (610)-321-0425 www.confocal-microscopy.com Confocal Application Notes Vol. 3 January 2005 Objective Scan field at zoom 1 (m) 10x 1500x1500 20x 750x750 40x 375x375 63x 238x238 100x 150x150 Table 1: Scan field size for different objective magnifications. The size of the scan field is independent of the selected scan format. However, the scan format will dictate how many pixels are used to cover the scan field and as a result, the size of the pixels will change with the format selected. For example: Using a 40x objective and zoom 1, the scan field is 375x375 m. If the selected scan format is 64x64, then these 375x375 m are covered by 64 lines with 64 pixels in each line. Every pixel will be 5.86x5.86 m (375 m/64=5.86). If you choose a scan format of 512x512 the pixel size will be reduced to 0.73 m (375 m/512=0.73). To illustrate this here are two images taken under the same conditions except that the scan format for the left image is set to 64x64; while the scan format for the right image is 512x512, resulting in a much smaller pixel size. One can clearly see the difference in resolution. 64x64 512x512 Leica Microsystems Inc. Telephone (610)-321-0460 410 Eagleview Blvd, Ste. 107 Toll Free 866-830-0735 Exton, PA 19341 Fax (610)-321-0425 www.confocal-microscopy.com Confocal Application Notes Vol. 3 January 2005 Scan format Pixel size (nm) @ Pixel size (nm) @ zoom 1 zoom 10 64x64 5860 586 128x128 2930 293 256x256 1460 146 512x512 732 73 1024x1024 366 36 2048x2048 183 18 4096x4096 91 9 Table 2: Scan format and pixel size for a 40x/1.25 N.A. objective at zoom 1 and zoom 10. 3. Zoom factor The zoom factor will determine the scan angle of the scan mirrors. Zooming in will reduce this angle, which in turn reduces the size of the scanned area. The scan format is unchanged and you now scan a smaller area of your sample with the same number of pixels that you used before, therefore the pixel size is reduced. The image is magnified to a greater extent and resolution is improved. Please keep in mind that this improvement of resolution is limited by the optical resolution of the objective! One cannot arbitrarily increase the zoom factor and improve resolution indefinitely. Oversampling will not add any more details to the image (see Nyquist theorem below)! We have to distinguish between this optical zoom and the digital zoom we will find in image processing software. A digital zoom works by mathematically increasing the image size using the original number of pixels and the image will become blurry. Leica Microsystems Inc. Telephone (610)-321-0460 410 Eagleview Blvd, Ste. 107 Toll Free 866-830-0735 Exton, PA 19341 Fax (610)-321-0425 www.confocal-microscopy.com Confocal Application Notes Vol. 3 January 2005 Zoom factor xy-image dimensions Pixel size (nm) (m) 1 375 732.42 2 187.5 366.21 4 93.75 183.11 8 46.88 91.55 16 23.44 45.78 32 11.72 22.9 Table 3: Zoom factor vs. image and pixel size. Scan format 512x512, 40x/1.25 N.A. objective. 4. Pixel size and the Nyquist theorem The Nyquist sampling theorem states that the sampling frequency must be greater than twice the bandwidth of the input signal to reconstruct the original input from the sampled data. What does this mean for scan format and pixel size? The pixel size should be set to about one-half to one-third of the minimum spacing that one wants to resolve. Let’s go back to the 40x objective. The objective has a theoretical optical resolution of 156 nm. To make full use of this resolution the pixel size should be approximately: rxy 156nm pixel size = = = 62.4nm 2.5 2.5 At a scan format of 512x512 and zoom 1 the pixel size is 730 nm. This pixel size is therefore too big to make full use of the resolving power of the 40x objective. Using a zoom factor of 12x with the 512x512 format will reduce the pixel size to 61 nm. We Leica Microsystems Inc. Telephone (610)-321-0460 410 Eagleview Blvd, Ste. 107 Toll Free 866-830-0735 Exton, PA 19341 Fax (610)-321-0425 www.confocal-microscopy.com Confocal Application Notes Vol. 3 January 2005 could also change the scan format to 4096x4096 at zoom 1 to achieve a pixel size of 91 nm. At this point you have to ask yourself if you really need 60 nm resolution? Are you trying to resolve details in your sample that small? Please keep in mind that scanning an image at 400Hz and 4096x4096 resolution will take 10 seconds. Now photobleaching and movement of your live-cell preparation may create a new problem. 5. Output of your digital image using third-party software, i.e. Adobe Photoshop When you open a confocal image in Adobe Photoshop and look at the image size, Photoshop may show you an image resolution of 72 dpi and an image size of 7x7 inches. This obviously does not reflect the physical size or resolution of your confocal image. Photoshop is rather displaying the image optimized for the output device; in this case your computer monitor (72 dpi is the standard resolution of most monitors). Let’s say you are asked to submit your image files at a resolution of 300 dpi. At a printer resolution of 300 dpi a 512x512 image will yield a 1.7x1.7 inch printout without introducing pixilation (512/300=1.7). A 1024x1024 image will allow for a 1024/300=3.4x3.4 inch printout (1024/300=3.4). Scan format Printout size (inch) Printout size (inch) @ 300 dpi @ 600 dpi 64x64 0.2 0.1 128x128 0.4 0.2 256x256 0.8 0.4 512x512 1.7 0.8 1024x1024 3.4 1.7 2048x2048 6.8 3.4 Table 4: Scan format and recommended size of the printout at 300 and 600 dpi printer resolution. Leica Microsystems Inc. Telephone (610)-321-0460 410 Eagleview Blvd, Ste. 107 Toll Free 866-830-0735 Exton, PA 19341 Fax (610)-321-0425 www.confocal-microscopy.com Confocal Application Notes Vol. 3 January 2005 If you have to change the dpi resolution of the image in Photoshop to match the output device (printer), please turn off “resample image”. This will allow you to change the output resolution of the image without changing the number of pixels. Resampling the image can introduce artifacts; in order to create new pixels the software has to interpolate. Summary 1. Try to achieve the highest optical resolution that you need for the job by selecting the right objective, scan format and zoom factor for your sample. 2. Match the scan format to the desired output resolution. Leica Microsystems Inc. Telephone (610)-321-0460 410 Eagleview Blvd, Ste. 107 Toll Free 866-830-0735 Exton, PA 19341 Fax (610)-321-0425 www.confocal-microscopy.com .
Recommended publications
  • About Resolution
    pco.knowledge base ABOUT RESOLUTION The resolution of an image sensor describes the total number of pixel which can be used to detect an image. From the standpoint of the image sensor it is sufficient to count the number and describe it usually as product of the horizontal number of pixel times the vertical number of pixel which give the total number of pixel, for example: 2 Image Sensor & Camera Starting with the image sensor in a camera system, then usually the so called modulation transfer func- Or take as an example tion (MTF) is used to describe the ability of the camera the sCMOS image sensor CIS2521: system to resolve fine structures. It is a variant of the optical transfer function1 (OTF) which mathematically 2560 describes how the system handles the optical infor- mation or the contrast of the scene and transfers it That is the usual information found in technical data onto the image sensor and then into a digital informa- sheets and camera advertisements, but the question tion in the computer. The resolution ability depends on arises on “what is the impact or benefit for a camera one side on the number and size of the pixel. user”? 1 Benefit For A Camera User It can be assumed that an image sensor or a camera system with an image sensor generally is applied to detect images, and therefore the question is about the influence of the resolution on the image quality. First, if the resolution is higher, more information is obtained, and larger data files are a consequence.
    [Show full text]
  • High-Aperture Optical Microscopy Methods for Super-Resolution Deep Imaging and Quantitative Phase Imaging by Jeongmin Kim a Diss
    High-Aperture Optical Microscopy Methods for Super-Resolution Deep Imaging and Quantitative Phase Imaging by Jeongmin Kim A dissertation submitted in partial satisfaction of the requirements for the degree of Doctor of Philosophy in Engineering { Mechanical Engineering and the Designated Emphasis in Nanoscale Science and Engineering in the Graduate Division of the University of California, Berkeley Committee in charge: Professor Xiang Zhang, Chair Professor Liwei Lin Professor Laura Waller Summer 2016 High-Aperture Optical Microscopy Methods for Super-Resolution Deep Imaging and Quantitative Phase Imaging Copyright 2016 by Jeongmin Kim 1 Abstract High-Aperture Optical Microscopy Methods for Super-Resolution Deep Imaging and Quantitative Phase Imaging by Jeongmin Kim Doctor of Philosophy in Engineering { Mechanical Engineering and the Designated Emphasis in Nanoscale Science and Engineering University of California, Berkeley Professor Xiang Zhang, Chair Optical microscopy, thanks to the noninvasive nature of its measurement, takes a crucial role across science and engineering, and is particularly important in biological and medical fields. To meet ever increasing needs on its capability for advanced scientific research, even more diverse microscopic imaging techniques and their upgraded versions have been inten- sively developed over the past two decades. However, advanced microscopy development faces major challenges including super-resolution (beating the diffraction limit), imaging penetration depth, imaging speed, and label-free imaging. This dissertation aims to study high numerical aperture (NA) imaging methods proposed to tackle these imaging challenges. The dissertation first details advanced optical imaging theory needed to analyze the proposed high NA imaging methods. Starting from the classical scalar theory of optical diffraction and (partially coherent) image formation, the rigorous vectorial theory that han- dles the vector nature of light, i.e., polarization, is introduced.
    [Show full text]
  • Preview of “Olympus Microscopy Resou... in Confocal Microscopy”
    12/17/12 Olympus Microscopy Resource Center | Confocal Microscopy - Resolution and Contrast in Confocal … Olympus America | Research | Imaging Software | Confocal | Clinical | FAQ’s Resolution and Contrast in Confocal Microscopy Home Page Interactive Tutorials All optical microscopes, including conventional widefield, confocal, and two-photon instruments are limited in the resolution that they can achieve by a series of fundamental physical factors. In a perfect optical Microscopy Primer system, resolution is restricted by the numerical aperture of optical components and by the wavelength of light, both incident (excitation) and detected (emission). The concept of resolution is inseparable from Physics of Light & Color contrast, and is defined as the minimum separation between two points that results in a certain level of contrast between them. In a typical fluorescence microscope, contrast is determined by the number of Microscopy Basic Concepts photons collected from the specimen, the dynamic range of the signal, optical aberrations of the imaging system, and the number of picture elements (pixels) per unit area in the final image. Special Techniques Fluorescence Microscopy Confocal Microscopy Confocal Applications Digital Imaging Digital Image Galleries Digital Video Galleries Virtual Microscopy The influence of noise on the image of two closely spaced small objects is further interconnected with the related factors mentioned above, and can readily affect the quality of resulting images. While the effects of many instrumental and experimental variables on image contrast, and consequently on resolution, are familiar and rather obvious, the limitation on effective resolution resulting from the division of the image into a finite number of picture elements (pixels) may be unfamiliar to those new to digital microscopy.
    [Show full text]
  • Super-Resolution Optical Imaging Using Microsphere Nanoscopy
    Super-resolution Optical Imaging Using Microsphere Nanoscopy A thesis submitted to The University of Manchester For the degree of Doctor of Philosophy (PhD) in the Faculty of Engineering and Physical Sciences 2013 Seoungjun Lee School of Mechanical, Aerospace and Civil Engineering Super-resolution optical imaging using microsphere nanoscopy Table of Contents Table of Contents ...................................................................................................... 2 List of Figures and Tables ....................................................................................... 7 List of Publications ................................................................................................. 18 Abstract .................................................................................................................... 19 Declaration ............................................................................................................... 21 Copyright Statement ............................................................................................... 22 Acknowledgements ................................................................................................. 23 Dedication ............................................................................................................... 24 1 Introduction ...................................................................................................25 1.1 Research motivation and rationale ........................................................25 1.2
    [Show full text]
  • Overcoming the Diffraction-Limited Spatio-Angular Resolution Tradeoff
    Variable Aperture Light Field Photography: Overcoming the Diffraction-limited Spatio-angular Resolution Tradeoff Julie Chang1 Isaac Kauvar1 Xuemei Hu1,2 Gordon Wetzstein1 1Stanford University 2 Tsinghua University Abstract Small-f-number Large-f-number Light fields have many applications in machine vision, consumer photography, robotics, and microscopy. How- ever, the prevalent resolution limits of existing light field imaging systems hinder widespread adoption. In this pa- per, we analyze fundamental resolution limits of light field cameras in the diffraction limit. We propose a sequen- Depth-of-Field 10 tial, coded-aperture-style acquisition scheme that optimizes f/2 f/5.6 the resolution of a light field reconstructed from multiple f/22 photographs captured from different perspectives and f- 5 Blur-size-[mm] number settings. We also show that the proposed acquisi- 0 100 200 300 400 tion scheme facilitates high dynamic range light field imag- Distance-from-Camera-Lens-[mm] ing and demonstrate a proof-of-concept prototype system. Figure 1. Photographs captured with different f-number settings With this work, we hope to advance our understanding of exhibit different depths of field and also diffraction-limited resolu- the resolution limits of light field photography and develop tion for in-focus objects (top row). This effect is most pronounced practical computational imaging systems to overcome them. for macro photography, such as illustrated for a 50 mm lens fo- cused at 200 mm (bottom plot). Using multiple photographs cap- tured from different perspectives and with different f-number set- tings, the proposed method seeks to recover a light field with the 1.
    [Show full text]
  • Improved Modulation Transfer Function Evaluation Method of a Camera at Any Field Point with a Scanning Tilted Knife Edge
    Improved Modulation Transfer Function evaluation method of a camera at any field point with a scanning tilted knife edge PRESENTED AT SPIE SECURITY+DEFENSE 2020 BY ETIENNE HOMASSEL, TECHNICAL PRODUCT MANAGER HGH, 10 10 rue Maryse Bastié 91430 IGNY –France +33 (1) 69 35 47 70 [email protected] Improved Modulation Transfer Function evaluation method of a camera at any field point with a scanning tilted knife edge Etienne Homassel, Catherine Barrat, Frédéric Alves, Gilles Aubry, Guillaume Arquetoux HGH Systèmes Infrarouges, France ABSTRACT Modulating Transfer Function (MTF) has always been very important and useful for objectives quality definition and focal plane settings. This measurand provides the most relevant information on the optimized design and manufacturing of an optical system or the correct focus of a camera. MTF also gives out essential information on which defaults or aberrations appear on an optical objective, and so enables to diagnose potential design or manufacturing issues on a production line or R&D prototype. Test benches and algorithms have been defined and developed in order to satisfy the growing needs in optical objectives qualification as the latter become more and more critical in their accuracy and quality specification. Many methods are used to evaluate the Modulating Transfer Function. Slit imaging and scanning on a camera, MTF evaluation thanks to wavefront measurement or imaging fixed slanted knife edge on the detector of the camera. All these methods have pros and cons, some lack in resolution, accuracy or don’t enable to compare simulated MTF curves with real measured data. These methods are firstly reminded in this paper.
    [Show full text]
  • Deconvolution in Optical Microscopy
    Histochemical Journal 26, 687-694 (1994) REVIEW Deconvolution in 3-D optical microscopy PETER SHAW Department of Cell Biology, John Innes Centre, Colney Lane, Norwich NR 4 7UH, UK Received I0 January 1994 and in revised form 4 March 1994 Summary Fluorescent probes are becoming ever more widely used in the study of subcellular structure, and determination of their three-dimensional distributions has become very important. Confocal microscopy is now a common technique for overcoming the problem of oubof-focus flare in fluorescence imaging, but an alternative method uses digital image processing of conventional fluorescence images-a technique often termed 'deconvolution' or 'restoration'. This review attempts to explain image deconvolution in a non-technical manner. It is also applicable to 3-D confocal images, and can provide a further significant improvement in clarity and interpretability of such images. Some examples of the application of image deconvolution to both conventional and confocal fluorescence images are shown. Introduction to alleviate the resolution limits of optical imaging. The most obvious resolution limit is due to the wavelength Optical microscopy is centuries old and yet is still at the of the light used- about 0.25 lam in general. This limi- heart of much of modem biological research, particularly tation can clearly be overcome by non-conventional in cell biology. The reasons are not hard to find. Much optical imaging such as near-field microscopy; whether it of the current power of optical microscopy stems from can be exceeded in conventional microscopy ('super-res- the availability of an almost endless variety of fluorescent olution') has been very controversial (see e.g.
    [Show full text]
  • Pursuing the Diffraction Limit with Nano-LED Scanning Transmission Optical Microscopy
    sensors Article Pursuing the Diffraction Limit with Nano-LED Scanning Transmission Optical Microscopy Sergio Moreno 1,* , Joan Canals 1 , Victor Moro 1, Nil Franch 1, Anna Vilà 1,2 , Albert Romano-Rodriguez 1,2 , Joan Daniel Prades 1,2, Daria D. Bezshlyakh 3, Andreas Waag 3, Katarzyna Kluczyk-Korch 4,5 , Matthias Auf der Maur 4 , Aldo Di Carlo 4,6 , Sigurd Krieger 7, Silvana Geleff 7 and Angel Diéguez 1,2 1 Electronic and Biomedical Engineering Department, University of Barcelona, 08028 Barcelona, Spain; [email protected] (J.C.); [email protected] (V.M.); [email protected] (N.F.); [email protected] (A.V.); [email protected] (A.R.-R.); [email protected] (J.D.P.); [email protected] (A.D.) 2 Institute for Nanoscience and Nanotechnology-IN2UB, University of Barcelona, 08028 Barcelona, Spain 3 Institute of Semiconductor Technology, Technische Universität Braunschweig, 38106 Braunschweig, Germany; [email protected] (D.D.B.); [email protected] (A.W.) 4 Department of Electronic Engineering, University of Rome “Tor Vergara”, 00133 Roma, Italy; [email protected] (K.K.-K.); [email protected] (M.A.d.M.); [email protected] (A.D.C.) 5 Faculty of Physics, University of Warsaw, 00-662 Warsaw, Poland 6 CNR-ISM, 00128 Rome, Italy 7 Department of Pathology, Medical University of Vienna, 1210 Wien, Austria; [email protected] (S.K.); [email protected] (S.G.) * Correspondence: [email protected] Abstract: Recent research into miniaturized illumination sources has prompted the development Citation: Moreno, S.; Canals, J.; of alternative microscopy techniques.
    [Show full text]
  • Superresolution Imaging Method Using Phase- Shifting Digital Lensless Fourier Holography
    Superresolution imaging method using phase- shifting digital lensless Fourier holography Luis Granero 1, Vicente Micó 2* , Zeev Zalevsky 3, and Javier García 2 1 AIDO – Technological Institute of Optics, Color and Imaging, C/ Nicolás Copérnico 7, 46980, Paterna, Spain 2 Departamento de Óptica, Univ. Valencia, C/Dr. Moliner, 50, 46100 Burjassot, Spain 3 School of Engineering, Bar-Ilan University, Ramat-Gan, 52900 Israel *Corresponding author: [email protected] Abstract: A method which is useful for obtaining superresolved imaging in a digital lensless Fourier holographic configuration is presented. By placing a diffraction grating between the input object and the CCD recording device, additional high-order spatial-frequency content of the object spectrum is directed towards the CCD. Unlike other similar methods, the recovery of the different band pass images is performed by inserting a reference beam in on-axis mode and using phase-shifting method. This strategy provides advantages concerning the usage of the whole frequency plane as imaging plane. Thus, the method is no longer limited by the zero order term and the twin image. Finally, the whole process results in a synthetic aperture generation that expands up the system cutoff frequency and yields a superresolution effect. Experimental results validate our concepts for a resolution improvement factor of 3. 2009 Optical Society of America OCIS codes: (050.5080) Phase shift; (100.2000) Digital image processing; (070.0070) Fourier optics and signal processing; (090.1995) Digital holography; (100.6640) Superresolution. References and links 1. A. Bachl and A. W. Lukosz, “Experiments on superresolution imaging of a reduced object field,” J.
    [Show full text]
  • Bing Yan Phd 2018
    Bangor University DOCTOR OF PHILOSOPHY All-dielectric superlens and applications Yan, Bing Award date: 2018 Awarding institution: Bangor University Link to publication General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. • Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain • You may freely distribute the URL identifying the publication in the public portal ? Take down policy If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. Download date: 09. Oct. 2021 ALL-DIELECTRIC SUPERLENS AND APPLICATIONS Bing Yan School of Electronic Engineering Bangor University A thesis submitted in partial fulfilment for the degree of Doctor of Philosophy May 2018 IV Acknowledgements First and foremost, I would like to express my sincere gratitude to my supervisor Dr Zengbo Wang for giving me this opportunity to work on such an exciting topic, and for his constant support during my entire PhD study and research. His guidance helped me in all time of research and writing of this thesis. I could not have imagined having a better advisor and mentor for my PhD study. During my PhD study, I have visited Swansea University and worked with many fascinating people for six months.
    [Show full text]
  • Measuring and Interpreting Point Spread Functions to Determine
    PROTOCOL Measuring and interpreting point spread functions to determine confocal microscope resolution and ensure quality control Richard W Cole1, Tushare Jinadasa2 & Claire M Brown2,3 1Wadsworth Center, New York State Department of Health, Albany, New York, USA. 2Department of Physiology, McGill University, Montreal, Quebec, Canada. 3Life Sciences Complex Imaging Facility, McGill University, Montreal, Quebec, Canada. Correspondence should be addressed to C.M.B. ([email protected]). Published online 10 November 2011; doi:10.1038/nprot.2011.407 This protocol outlines a procedure for collecting and analyzing point spread functions (PSFs). It describes how to prepare fluorescent microsphere samples, set up a confocal microscope to properly collect 3D confocal image data of the microspheres and perform PSF measurements. The analysis of the PSF is used to determine the resolution of the microscope and to identify any problems with the quality of the microscope’s images. The PSF geometry is used as an indicator to identify problems with the objective lens, confocal laser scanning components and other relay optics. Identification of possible causes of PSF abnormalities and solutions to improve microscope performance are provided. The microsphere sample preparation requires 2–3 h plus an overnight drying period. The microscope setup requires 2 h (1 h for laser warm up), whereas collecting and analyzing the PSF images require an additional 2–3 h. INTRODUCTION Rationale lens, and it is diffracted. The result is an image of the point source All rights reserved. The use of high-resolution confocal laser scanning microscopy that is much larger than the actual size of the object (compare Inc (CLSM) spans virtually all fields of the life sciences, as well as Fig.
    [Show full text]
  • Generalized Quantification of Three-Dimensional Resolution in Optical Diffraction Tomography Using the Projection of Maximal Spatial Bandwidths
    Generalized quantification of three-dimensional resolution in optical diffraction tomography using the projection of maximal spatial bandwidths CHANSUK PARK,1,2 SEUNGWOO SHIN,1,2 AND YONGKEUN PARK1,2,3,* 1Department of Physics, Korea Advanced Institutes of Science and Technology (KAIST), Daejeon 34141, Republic of Korea 2KAIST Institute for Health Science and Technology, KAIST, Daejeon 34141, Republic of Korea 3Tomocube, Inc., Daejeon 34051, Republic of Korea *Corresponding author: [email protected] Optical diffraction tomography (ODT) is a three-dimensional (3D) quantitative phase imaging technique, which enables the reconstruction of the 3D refractive index (RI) distribution of a transparent sample. Due to its fast, non- invasive, and quantitative 3D imaging capability, ODT has emerged as one of the most powerful tools for various applications. However, the spatial resolution of ODT has only been quantified along the lateral and axial directions for limited conditions; it has not been investigated for arbitrary-oblique directions. In this paper, we systematically quantify the 3D spatial resolution of ODT by exploiting the spatial bandwidth of the reconstructed scattering potential. The 3D spatial resolution is calculated for various types of ODT systems, including the illumination-scanning, sample- rotation, and hybrid scanning-rotation methods. In particular, using the calculated 3D spatial resolution, we provide the spatial resolution as well as the arbitrary sliced angle. Furthermore, to validate the present method, the point spread function of an ODT system is experimentally obtained using the deconvolution of a 3D RI distribution of a microsphere and is compared with the calculated resolution. The present method for defining spatial resolution in ODT is directly applicable for various 3D microscopic techniques, providing a solid criterion for the accessible finest 3D structures.
    [Show full text]