INTERIOR WORK OF CALL CENTER IN GVK EMRI CAMPUS AT AHMEDBAD.

TECHINICAL SPECIFICATION OF INTERIOR WORK

1. GENERAL

1. The detailed specifications given hereafter are for the items of works described in the schedule of quantities attached herein, and shall be guidance for proper execution of work to the required standards

2. It may also be noted that the specification are of generalized nature and these shall be read in conjunction with the description of item in schedule of quantities and drawings.

3. The work also includes all minor details of construction which are obviously and fairly intended and which may not have been referred to in these documents but are essential for the entire completion in accordance with standard engineering practice.

4. The Architects, PMC and the Employer shall be the sole deciding authority as to the meaning; interpretations and implication for various provisions of the specifications and his decision in writing shall be final and binding on all concerned.

5. In case any difference or discrepancy between the tender specifications and the description in the bill of quantities, the bill of quantities shall take precedence.

6. In case any difference or discrepancy between the tender specifications and the tender drawing, the tender specification shall take precedence

7. Unless specifically otherwise mentioned, all the applicable latest codes and standards published by the Bureau of Indian Standards and all other standards, shall govern in all respects of design, workmanship, quality, properties of materials, method of testing and method of measurements.

8. These specification shall be read in conjuction with the latest ,IS specification In case this specification are found wanting in any way the relevant C.P.W.D. Specifications shall apply .

9. MATERIALS TO BE APPROVED /BEST QUALITY:The whole of the materials. Employed in connection with the permanent work ,shall be new and the best of its kind . All materials shall be in accordance with these specifications and shall be as approved by the Architect/PMC.

10. STANDARDS: Except where otherwise specified and permitted by the Architect, all materials shall conform to the latest edition of Indian standard specification .

2. MATERIALS

Page 1 1. JOINERY

1.1 (a) Timber: Timber shall be second class hard . The timber, seasoning and treatment shall be done as per IS 1141-1973 and IS 402-1962.

(b) : Shall be BWP grade conforming to IS 710 – 1975. (c) Block boards: Shall conform to IS 1659 – 1969 BWP grades and shall be with 6 mm thick lipping. (d) Adhesive used for wood work and joinery work shall conform to IS – 849 – 1957. 1.2. Timber:

(a) Timber for use in unframed clean sawn wood work for wooden plugs, rough grounds fillets or the like shall be first class hard wood. (b) The surface of wood sections, boards, ply cutting if touching or embedded in walls etc. shall be treated with colourless wood preservative on all surfaces of an approved quality and make. Nails and spikes shall not be used in joinery works, but instead bamboo wood pins of proper size shall be used. (c) Where length of any member exceeds 3.00 meters, approved type of joint shall be provided without any extra cost. (d) Timber surface of all and joinery work shall be wrought and prepared smooth. (e) Wooden plugs for fixing timber fixture and fittings and the like shall be built into walls. Alternatively fill plugs made out of asbestos cement powder or PVC plugs sleeves shall be used wherever specified. 1.2.1 Vertical members of timber door (cup board / cabinets / lab tables / lab counters) frames shall be embedded at floor level if indicated. The bottom of shutters shall be 5 mm above the finished floor level.

1.2.2 Door shutters: All door shutters (internal or external except steel shutters) for all blocks shall be factory made flush door shutters confirming to IS specifications. Doors shutters shall be of the following specifications.

(a) Flush door shutters : Flush door shutters shall be 35 mm thick / solid core type no decorative factory made confirming to IS 2202 and ISI marked with block board

Page 2 core (confirming to the requirements as pr IS-1659 1969) with internal hard wood lipping and both faces commercial ply veneered. Adhesive used shall be (b) Phenol formaldehyde synthetic resin conforming to BWP types specified in IS- 848- 1974. 1.2.3 Contractor shall obtain the approval for the name of the manufacturer of the flush door shutters from the Project Manager / Architect before placing the supply order. While asking for the approval, copy of the “Bureau of Indian Standard” letter under which manufacturer has been authorized to mark the product with ISI marking should be attached. Project Manager and Architect before giving the approval shall ensure that the validity date of license has not expired.

1.3 Testing of flush door shutters: On receipt of the shutters at site the Project Manager or the Architect shall be entitled to get the samples of door shutters tested in any approved laboratory. From each lot of approximately 500 shutters, one shutter shall be selected at random by the Project Manager / Architect. The balance shutters from the lot shall not be installed until the lab report is received confirming that the sample complies with the requirement of IS. The cost of replacement of the door shutters selected as samples, their transportation to the laboratory and cost of testing by the laboratory shall be borne by the contractor, and shall be deemed to be included in the lump sum rates quoted in Schedule ‘A’ Part I.

2. Adhesives 2.1 Nature of the surface to be bonded when bonding to walls, the regularity of the age of plaster or cement screeds should be particularly noted. The area to be bonded together with the size of panels, tiles, etc, should be stated. 2.2 Location of the installation Not only should mention be made of internal and external locations. But the actual conditions of service, i.e. maximum temperature, Humidity, structural movement, etc should also be assessed.

2.3 Assembly technique Possible conditions of site assembly should be noted and

Page 3 restrictions on technique assessed, i.e. whether it is possible to apply adhesive to both surfaces, whether it is necessary to position the assembly after making the bond etc. Furnished with these facts, most adhesive suppliers will suggest suitable products from their range for the purpose in mind and give assembly details and costing. 2.4 Application: the required preparation of the surfaces to be bonded should also be carried out carefully. All surfaces should be firm and free from dust. Loosed material on brickwork, etc, should be removed by thorough use of a wire brush. Surfaces with a high gloss should be roughened with or emery. It is usually necessary to make sure that the surfaces are dry, and to protect the job from rain if necessary during assembly. 2.5 Clean tools should always be used for applying the adhesive. When making an overall bond (e.g. with contact adhesive) care should be taken to obtain an even film of adhesive. On porous surfaces it may be necessary to apply two coats to ensure an adequate dry film on the surface. 2.6 A large number of adhesion failures are caused by using an incorrect drying time. When a two-way dry-stick is used it is essential that the manufacturers’ instructions are closely followed on this point. If the drying time is too long, then the two adhesive films will not fuse completely and once again a poor bond will result. A similar effect will be obtained once again a poor bond will result. A similar effect will be obtained if the adhesive films are not thoroughly pressed into contact. With most adhesives high pressure to the assembly to bring the two bonding surfaces into intimate contact must be removed before applying adhesive.

SPECIFICATIONS FOR WOOD WORK

1.0 SCOPE: The works covered under this specification consist of providing, making and fixing of wooden frames for doors in accordance with these specifications and drawings.

Page 4 2.0 APPLICABLE CODES & SPECIFICATIONS: The relevant I.S. specifications, standards and codes given below are made a part of this specification. All standards, specifications, code of practices referred to herein shall be the latest edition including all applicable amendments, revisions and additional publications.

List of Indian Standards

No. I.S. No. I.S. Particulars 1 I.S. 287 Recommendations for maximum permissible moisture content of timber. 2 I.S. 401 Code of practice for preservation of timber. 3 I.S. 851 Specification for synthetic resin adhesives for construction work in wood. 4 I.S. 1141 Code of practice for seasoning of timber. 5 I.S. 1200 Method of measurement of building and civil engineering (Part-XXI) works. (Wood work and joinery) 6 I.S. 1708 Method of testing of small clear specimens of timber. (Part-1 to 18) 7 I.S. 7196 Specification for hold fast.

3.0 WOOD FRAMES:

nd Door frames shall be of 2 quality timber of C.P. teak wood or as specified in the BOQ and brought and put up to section as indicated on the drawings or as directed by the Architects.

They shall be properly framed and mortised and tongued together at right angles and set correctly in the masonry or concrete.

The door frame shall rest on structural slabs and not on finished floor level.

M.S. holdfasts 230 mm long, 40 mm wide and 3 mm thick shall be fixed as shown in

Page 5 drawing or as directed by the Architects to hold the teakwood rough ground frames/ door frames firmly in the masonry.

Where the rough ground/ frames are placed by the side of concrete surface they shall be fixed firmly against the concrete surface by means of teak wood gutties and screws.

All m. s. hold fast shall be fastened to the frame using adequate number of M. S. screws all other door frames shall be fixed as per fixing details shown in relevant drawings.

The surfaces of frames in contact with masonry or concrete shall be painted with two coat of bituminous .

The frame shall be as per drawing and shall be provided with triangular keys for the plaster if indicated in the drawing.

All frames shall be protected with one coat of approved wood primer as specified.

While fixing the frames in position, the vertical members shall be held rigid temporarily by means of wooden battens to avoid bending or distortion of members and to keep door frame exactly in plumb.

The teakwood beading/ cover mould/ stopper of the specified sizes shall be fixed on to the frame as shown in the drawings and shall be fixed on to the frame as shown in the drawings and shall be free from knots and sap wood.

SPECIFICATIONS FOR FLUSH DOOR SHUTTER

1 SCOPE: The works covered under this specification consist of providing and fixing block flush door shutter in accordance with the specification and drawings. 2 APPLICABLE CODES & SPECIFICATIONS: The relevant I.S. specifications, standards and codes given below are made a part of this specification. All standards, specifications, code of practices referred to herein

Page 6 shall be the latest edition including all applicable amendments, revisions and additional publications.

List of Indian Standards

No. I.S. No. I.S. Particulars 1 I.S. 204 (Part – I) Specification for tower bolts (ferrous metal) 2 I.S. 204 (Part – II) Specification for tower bolt (non ferrous metal) 3 I.S. 208 Specification for door handles 4 I.S. 723 Specification for steel countersunk head wire nails. 5 I.S. 848 Specification for synthetic resign adhesives for plywood 6 I.S. 1200 (Part – Method of measurement of building and civil XXI) engineering works. (Wood work and joinery) 7 I.S. 1341 Specification for steel butt hinges. 8 I.S. 1659 Specification for block boards. 9 I.S. 1708 (Part-1 Method of testing of small clear specimens of to 18) timber. 10 I.S. 1734 (Part-1 Method of test for plywood. to 20) 11 I.S. 2202 Specification for wooden flush door shutters. (Solid core type). 12 I.S. 2209 (Part – I) Specification for mortise lock of timber. 13 I.S. 3564 Specification for door closers. 14 I.S. 4992 Specification for door handles for mortise lock. 15 I.S. 6760 Specification for slotted counter sunk head wood screws.

3.0 BLOCK BOARD FLUSH DOOR SHUTTER:

Flush door shutter shall have a solid core and may be of the decorative or non- decorative type conforming to I.S. 2202.

Page 7 The thickness and type of shutter shall be as specified in item of schedule of quantities.

Width and height of shutter shall be as shown in the drawings or as directed by the Architects. All four edges of shutter shall be .

The shutter shall be free from twist or wrap in its . The moisture content in timbers used in the manufacture of flush door shutters shall be not more than 12 percent when tested according to I.S. 1708.

The core of flush door shall be a block board having wooden strips held in a frame constructed of stiles and rails. Each stile and rail shall be a single piece without any joint. The width of the stiles and rails shall not be less than 75 mm and not more than 100 mm. The width of each wooden strip shall not exceed 25 mm. Stiles, rails and wooden strips forming the core of a shutter shall be of equal and uniform thickness. Wooden strips shall be parallel to the stiles.

End joints of the pieces of wooden strips of small lengths shall be staggered. In a shutter, stiles and rails shall be of one species of timber. Wooden strips shall also be one species only but it may or may not be the same species as that of the stiles and rails

The face panel shall be formed by gluing by the hot-press process on both faces of the core either plywood or cross-bands and face veneers. The thickness of the cross bands as such or in the plywood shall be between 1.0 mm and 3.0 mm. The thickness of the face veneers as such or in the plywood shall between 0.5 mm and 1.5 mm for commercial veneer and between 0.5 and 1.0 mm for decorative veneers. The direction of the veneer adjacent to the core shall be at right angles to the direction of the wooden strips. Finished faces shall be sanded to smooth even texture.

Lipping where specified, shall be provided internally on all edges of the shutters. Lipping shall be done with battens of first class teakwood or as specified. Joints shall not be permitted in Lipping.

The shutters shall be single leaf or double leaves as shown in the drawings or as directed by

Page 8 the Architects. In case of double leaves shutters the meeting at stiles shall be rebated by one third the thickness of the shutter. The rebating shall be either splayed or square type.

Wherever specified the opening for glazing of size as shown in drawing or as directed shall be made in the shutter for vision panel and or louver. Opening for glazing shall be made in the shutter for vision panel and or louver. Opening for glazing shall be lipped internally with teakwood batten of specified size.

Tolerance on width and height shall be (+ or -) 3 mm and on thickness it shall be (+ or -) 1.2 mm. The thickness of the door shutter shall be uniform through out with a permissible variation of not more than 0.8 mm when measured at any two points.

Adhesive used for bonding various components like core, core frame, Lipping, cross bands, face veneers plywood etc. of flush door shutters and for bonding plywood shall be phenol formaldehyde synthetic resin conforming to I.S. 848.

Samples of flush door shutters shall be subjected to following tests in accordance with I.S. 2202 (Part – I & II): End immersion test. Knife test. Glue adhesion test.

All the sample shutters when tested shall satisfy the requirements of the tests as laid down in I.S. 2202 (Part – I & II) if the number of samples found unsatisfactory or a test is two or more the entire lot shall be considered unsatisfactory.

5.0 TEAK WOOD GLAZED SHUTTERS:

The specifications for teak wood paneled shutter shall generally apply to glazed Shutters for frame, stiles etc. The sash and beading required for glazing shall be of the best teak wood and shall be fixed as per the design shown in relevant drawing. Any mouldings, carvings shown shall be worked out from the teak wood member of bigger size.

Page 9 6.0 GLAZING:

Glazing shall be generally with 5.5 mm/8 mm/12mm or as specified in the BOQ. Thick plain sheet glass/bajra glass unless otherwise mentioned in the schedule of quantities. The detailed specifications for glazing given hereafter shall be followed generally.

7.0 MISCELLANEOUS:

Wherever mentioned in the Schedule of quantities, vision panels, Venetians, plastic laminates, push plates etc. shall be provided in all doors. The vision panels shall be of size mentioned in the drawing and shall be provided with teak wood lipping all-round the glass. The glass shall be of required thickness as specified of best quality, free from defects.

Teak wood Venetians or louvers shall generally conform to relevant specifications of timber. Necessary grooves and rebate in frames shall be provided as per drawing. Formica or approved equivalent plastic laminate of required design, required shade and colour shall be provided and fixed on flush door to the required size on any side of the shutter as shown in drawing. It shall be fixed with Fevicol or any other approved adhesive. Fixing shall be done in such a way that there shall not be any air gap, warpage or undulations on the surface. Finished surface of Formica shall be cleaned with wax polish. The shutters shall be painted on commercial facing side with two coats of synthetic/flat oil paint of approved shade and make over an approved coat of primer. The decorative veneer side of the shutter shall be wax or French polished with two or more coats so as to render a satisfactory surface.

The flush doors shall be single leaf or double leaf type as mentioned in the schedule of quantities. In case of double leaf shutters, the meeting of the stiles shall be rebated 20 mm. And it shall be either splayed or square type or the T.W. lipping around the meeting shall not be less than 35 mm. deep. The meeting stiles shall be in single piece.

Sufficient care shall be taken to prevent any damage and loss of shape during handling, transporting, stacking, fixing etc. The door shutters shall be handled with

Page 10 utmost care to prevent any surface damage, warping etc.

SPECIFICATIONS FOR FITTINGS AND FIXTURES

1.0 SCOPE OF WORK:

The works covered under these specifications consist of supplying different types of fittings and fixtures required for doors, windows, ventilators etc. The supply shall be in accordance with the specification, drawings / approved samples. Samples of various fittings and fixtures proposed to be incorporated in the work shall be submitted by the contractor for approval of the Architects and Employer before order for bulk supply is placed.

2.0 GENERAL:

All fittings and fixtures shall conform to relevant IS code and made of oxidized brass, anodized aluminium, iron oxidized (M.S.) or as specified. These shall be well made reasonably smooth and free from sharp edges, corners, flaws and other defects. Screw holes shall be counter sunk to suit the heads of the specified screws. All hinges pins shall be of steel for brass hinges and aluminium alloy NR-6 or steel pins for aluminium hinges with nylon washers or as specified. All riveted heads pertaining to hinge pins shall be well formed. Screws supplied for fittings shall be of the same metal and finish as the fittings. However brass cadmium plated/chromium plated screws shall be supplied with aluminium fittings. Samples of each fixture/ fitting shall be furnished by the contractor for approval of the Architects and Employer. Order for procurement of fittings and fixtures in bulk shall be placed only after approval by the architects and Employer.

The fittings and fixtures to be incorporated in the work shall be strictly according to the approved sample. Fittings shall be fixed in proper position as shown in the drawing and as directed by the Architects. These shall be truly

Page 11 vertical or horizontal as the case may be. Screws shall be driven home with a screwdriver and not hammered in. Recess shall be cut to the exact size and depth for the counter sinking of hinges. The fittings and fixtures shall be fixed in a workman like manner and any damages done either to fittings and fixtures or to the shutter frames etc. should be rectified by the contractor at his own cost. Fittings shall be of Mild steel, Stainless steel, aluminium, brass or as specified. The fittings shall be well made, smooth, and free from sharp edges and corners, flaws and other defects. Mild steel fittings shall be bright satin finish black stone enameled or copper oxidized (black finish), nickel chromium plated or as specified.

Aluminium fittings shall be anodized to natural matt finish or dyed anodic coating less than grade AC 10 of IS: 1868

Stainless steel fittings shall be non-magnetic, rust & moisture proof, strong & sturdy. Pin of hinges shall also be of stainless steel.

3.0 BUTT HINGES:

Oxidized Brass and aluminium hinges shall be manufactured from the extruded sections and shall be free from cracks and other defects. M.S. butt hinges shall be free from cracks and other defects. M.S. butt hinges shall be cranked and manufactured from M.S. Sheets. All butt hinges shall conform to latest I.S. specifications butt hinges shall generally condorm to releval I.S viz IS 1341 (M.S.) IS : 205 (Cast brass &aluminium, IS : 362 (Parliament hinges); IS : 453 sprig hinges, IS : 3818 (Piano hinges) etc. The size of butt hinges shall be taken as the length of the hinge. Width of the hinge shall be measured from the centre line of hinge pin to end of flange.

4.0 PARLIAMENTARY HINGES:

These shall be manufactured from extruded section for oxidized brass and anodized aluminium and from M.S. sheets for iron oxidized and shall be free from cracks and other defects. The size of the parliamentary hinges shall be taken as the width between open flanges, while the depth shall be as specified.

Page 12 5.0 PIANO HINGES:

These shall be generally conformed to I.S. 3818 and shall be made of brass oxidized, aluminium anodized, iron oxidized (M.S.) or as specified. Piano hinges shall be fixed in the entire length of the cupboard shutters in a single piece. No joints shall be allowed. Crank

6.0 BOX HINGE: These shall be manufactured from screw on nickel plated steel with opening angle 95

degree, cup diameter 35mm. These shall be 16mm cranked. The size of butt hinges

shall be taken as the length of the hinge.

7.0 TOWER BOLTS:

These shall generally conform to IS 204 (Part II & I). They shall be well made and shall be free from defects.

The tower bolts shall be of the following types: i) MS semi barrel tower bolt with ms sheet pressed barrel and G.I. bolt or with ms barrel and MS Sheet bolt.

ii) Oxidized brass barrel tower bolt with brass sheet barrel and rolled or drawn brass bolt

iii) Anodized aluminium tower bolt with barrel and bolt of extruded sections of aluminium alloy.

In case of M.S. tower bolt plates and straps after assembly shall be firmly riveted or spot welded properly.

The knobs of brass tower bolts shall be cast and the bolt fixed into the knob firmly as per I.S. specifications. The tower bolt shall be finished to correct shape and pattern so as to have a smooth action. Wherever specified, aluminium barrel tower bolts shall be manufactured from extruded sections of barrel & bolts. Knobs shall be properly

Page 13 screwed to the bolt and riveted at the back. The size of the tower bolt shall be taken as the length of barrel without top socket. 8.0 DOOR LATCH: This shall be of MS, cast brass or as specified shall have smooth sliding action. MS Latch shall be copper oxidized (black finish) or as specified. Brass Latch shall be finished bright, CP or oxidized or as specified 9.0 ALDROPS: These shall be oxidized brass or anodized aluminium, iron oxidized or as specified and shall be capable of smooth sliding action and shall be as per relevant I.S. Brass sliding door bolt (aldrop) shall be made from rolled brass generally confirming to IS : 2681. M.S. sliding door bolt shall generally conform to I.S.281. The hasp shall be of cast brass and screwed to the bolt in a workman like The hasp shall be of cast brass and screwed to the bolt in a workman like manner. Alternatively the hasp and the bolt may be in one piece. Bolts shall be finished to shape and threaded with worth standard and provided with round brass washers and nuts of square or hexagonal shape. All components shall be smooth and polished. The leading dimensions of aldrop shall be as the length of the bolt and specified diameter.

10.0 DOOR HANDLES- BOW/PLATE HANDLES:

These should generally conform to IS: 208. Unless otherwise specified door handles shall be of 100 mm size & windows handles of 75 mm size. These shall be of cast brass of specified size, shape and pattern as approved by the Architects. All edges and corners shall be finished smooth and correct to shape and dimensions. Brass handles shall be finished bright, chromium plated or oxidized as specified. Anodized aluminium or iron oxidized (m.s.) handles shall be of specified Brass handles shall be finished bright, chromium plated or oxidized as specified. Anodized aluminium or iron oxidized (M.S.) handles shall be of specified size, shape and pattern. The size of the handle is taken as the inside grip of the handle. In case of iron oxidized handles, the same shall be manufactured from M.S. sheet pressed into oval section as per I.S.

11.0 MORTISE LOCK & LATCH:

Page 14 This should generally conform to I.S. 2209. Handles shall conform to IS 4992. Mortise lock with latches and a pair of level handles shall be 6 levers, with zinc alloy pressure die cast/brass or as specified body of approved quality, and shall be right or left handed as specified. The pair of handles shall be either brass chromium plated or anodized aluminium of approved shape and pattern or as specified. It shall be of the best Indian make of approved quality. The size of the lock shall be determined by its length. The lock for single leaf door shall have plain face and that for double leaf door a rebated face. Level handles with springs shall be mounted on plates and shall be of approved quality, anodized aluminium or as specified. 12.0 DOOR CLOSER: Shall be as specified in the BOQ and list of approved make of materials.

The contractor shall provide for all the incidentals required for fixing these fixtures and fittings such as cadmium plated screws etc. Fittings and fixtures shall be fixed securely in a workman like manner all as directed by the Engineer-in- charge. Any of the fixtures damaged during the fixing shall be removed and new one fixed in their place and the surface of joinery made good where affected, at his own expense. Mortise plates shall be used over holes where the bolts enter in the wood work. Metal sockets shall be provided to all bolts where the shoot enter brick, stone, concrete etc. The incidental Fixtures like mortise plates, metal sockets, screws etc. shall not be paid for separately.

13.0 MORTICE NIGHT LATCH:

This is a mortice lock having a single spring bolt withdrawn from the outside by using the key and from inside by turning the knob and with an arrangement whereby the lock can be prevented from being opened by its key from outside while the night latch is used from inside the room. This should generally conform to IS: 3847. It shall be cast or sheet brass, cast or sheet aluminium alloy or mild steel as specified and of approved make. These shall be bright finished or copper oxidized (black) finish as specified. Normal size of the latch shall be denoted by the length of the face over the body in millimeters. 14.0 FLOOR DOOR STOPPER: The floor door stopper shall conform to IS: 1823. This shall be made of cast brass of overall size as specified and shall have rubber cushion.

Page 15 The shape and pattern of stopper shall be approved by the Architects. It shall be of brass finished bright, chromium plated or oxidized or as specified. The size of door stopper shall be determined by the length of its plate. The body of the door stopper shall be cast in one piece. All parts of the door stopper shall be of good workmanship and finish and free from surface and casting defects. Aluminium stopper shall have anodic coating of not less than grade AC-10 of IS 1868.

SPECIFICATIONS FOR GLASS AND GLAZING

1.0 SCOPE OF WORK:

The work covered by this specification include furnishing and fixing the glass panes to teak wood or steel doors and windows, strictly in accordance with these specifications and drawings. 2.0 MATERIALS:

2.1 Glass: The glass shall be special selected/selected ordinary quality of approved make, as specified and it shall be free from bubbles, flaws specks, waves, air holes, distortion, scratches or other defects. The glasses in bulk quantities shall be brought to site in Makers original packings and Makers guarantee shall be produced if called for by the Architect PMC and Employer. The glass shall be of required thickness as mentioned in the items of schedule of quantities and/or drawing or as directed by the Architects. The contractor shall submit the sample of the glass which he proposes to use on the work and only such approved quality of glass shall be used in the works. The glass brought to site shall be protected against damages. Wherever frosted (obscure) glass is mentioned in the item of schedule of quantities and/or shown in drawings, the glass shall be of sand blown pattern and shall also be got approved by the Architect and Employer.

2.2 Beading: The beading shall be of teak wood of superior quality timber in case of teak wood doors and windows and/or required sizes mentioned in the items of

Page 16 schedule of quantities and/or shown in drawing. In case of steel doors and windows, the beading shall be anodized aluminium beading of channel section as per sizes mentioned in the item and/or shown in the drawing. The junction of the beadings shall be mitre jointed.

3.0 WORKMANSHIP: The glass shall be cut to the required sizes of panels where it is to be fitted, and it shall be so cut that it fits properly in the frames without rattling. Pre- measurement of each panel prior to the cutting of glass is essential. The beading shall then be fixed to glass panes and screwed at close intervals not more than 10 cm. from each corner and the intermediate not more than 20 cm. apart. When glass panes are fixed with wooden beadings having mitred joints or aluminium beading thin layer of glazier putty shall be applied covering the area in contact between the glass and sashbars and beadings. In case of louvers, all the exposed edges of the glass shall be ground properly.

4.0 GENERAL: After the inspection is over and permitted by the Architects, glass panes shall be cleaned off any labels, smears and spots and shall be washed from both the sides and all glazing left clear, perfect and free from rattling. The contractor shall provide all the scaffolding, tools and plants for fixing the glass panes at his own cost. In case of steel windows, any hardware if fixed in position, shall be removed temporarily before fixing the glass panes and which shall be re fixed back in position, all at the contractors cost.

SPECIFICATIONS FOR PAINTING

1.0 SCOPE OF WORK: The work covered under these specifications consist of furnishing the various types of paints and also the workmanship for these items, in strict compliance with these specifications, which are given in detail here-in-after with the item

Page 17 of schedule of quantities.

2.0 MATERIALS:

2.1 Paints, oils, etc. Of approved brand and manufacture shall be used. Ready mixed paints as received from the manufacturer without any admixture shall be used.

If for any reason, thinning is necessary in case of ready mixed paint, the brand of thinner recommended by the manufacturer or as instructed by the Architects shall be used. Approved paints, oils or varnishes shall be brought to the site of work by the contractor in their original containers in sealed condition. The materials shall be brought in at a time in adequate in sealed condition. The materials shall be brought in at a time in adequate quantities to suffice for the whole work or at least a fortnights work. The materials shall be kept in the joint custody of the contractor and the Employer. The empties shall not be removed from the site of work, till the relevant item of work has been completed and permission obtained from the Architect and Employer.

2.2 The contractor shall associate the chemist of paint manufacturers before commencement of work, during and after the completion of work who shall certify the suitability of the surface to receive painting and the paint before use etc. 3.0 COMMENCING WORK: 3.1 Scaffolding: Wherever scaffolding is necessary, it shall be erected on double supports tied together by horizontal pieces, over which scaffolding planks shall be fixed. No ballies, bamboos or planks shall rest on or touch the surface which is being painted.

3.2 Where ladders are used, pieces of old gunny bags shall be tied on their tops to avoid damage or scratches to walls.

3.3 For painting of the ceiling, proper stage scaffolding shall be erected.

3.4 Painting shall not be started until and unless the Architects/Employer has inspected the items of work to be painted, satisfied himself about their proper quality and given his approval to commence the painting work.

Page 18 3.5 Painting, except the priming coat, shall generally be taken in hand after all other builders work, practically finished.

3.6 The rooms should be thoroughly swept out and the entire building cleaned up at least one day in advance of the paint work being started. 4.0 PREPARATION OF SURFACE: 4.1 The surface shall be thoroughly cleaned. All dirt, rust, scales, smoke and grease shall be thoroughly removed before painting is started. Minor patches if any in plastered/form finished surfaces shall be repaired and finished in line and level in C.M. 1:1 and cracks & crevices shall be filled with approved filler, by the contractor at no extra cost to the Department. The prepared surface shall have received the approval of the Architects after inspection, before painting is commenced.

5.0 APPLICATION:

5.1 Before pouring into smaller containers for use, the paint shall be stirred thoroughly in its containers. When applying also, the paint shall be continuously stirred in the smaller containers so that consistency is kept uniform.

5.2 The external surfaces of the buildings under reference including the R.C.C. Jalli, fins and the panels above and below the window etc. Shall be finished in different colours of approved shade. The contractor will make suitable samples at site for Departments approval before taking up the work in hand and they will be allowed to proceed with the work only after getting Departments approval for the same.

5.3 The painting shall be laid on evenly and smoothly by means of crossing and laying off, the later in the direction of the grain in case of wood. The crossing & laying off consists of covering the area with paint, brushing the surface hard for the first time and then brushing alternately in opposite directions two or three time and then finally brushing lightly in direction at right angles to the same. In this process, no brush marks shall be left after the laying off is finished. The full process of crossing and laying will constitute one coat.

5.4 Where so stipulated, the painting shall be done with spraying. Spray machine used

Page 19 may be (a) a high pressure (small air aperture) type or (b) a low pressure (large air gap) type, depending on the nature and location of work to be carried out. Skilled and experienced workmen shall be employed for this class of work. Paints used shall be brought to the requisite consistency by adding a suitable thinner. Spraying should be done only when dry condition prevails.

5.5 Each coat shall be allowed to dry out thoroughly and rubbed smooth before the next coat is applied. This should be facilitated by thorough ventilation.

5.6 Each coat except the last coat, shall be lightly rubbed down with sand paper or fine pumice stone and cleaned of dust before the next coat is laid.

5.7 Each coat except the last coat shall be lightly rubbed down with sand paper or fine pumice stone and cleaned of dust before the next coat is laid.

5.8 No left over paint shall be put back into the stock tins. When not in use, containers shall be kept properly closed.

5.9 The final painted surface shall present a uniform appearance and no streaks, blisters, hair marks from the brush or clogging of paint puddles in the corners of panels, angles of moldings etc. shall be left on the work.

5.10 In case of cement based paints/primers, the absorbent surfaces shall be evenly damped so as to give even suction. In any weather, freshly painted surfaces shall be kept damp for at least two days.

5.11 In painting doors and windows, the putty around the glass panes must also be painted, but care must be taken to see that no paint stains etc. are left on the glass. Tops of shutters and surfaces in similar hidden locations shall not be left out while painting. Perspect covers of electrical switch boxes have to be painted from inside by removing them. Care shall be taken while removing them in position after painting with respective approved paints. In painting steel work, special care shall be taken while painting over bolts, nuts, rivets, overlaps etc.

Page 20 5.12 The additional specifications for primer and other coats of paints shall be as in accordance to the detailed specifications under the respective headings.

5.13 Any damage caused during painting work to the existing works/surfaces shall be made good by the contractor at his own cost. 6 BRUSHES AND CONTAINERS: 6.1 After work, the brushes shall be completely cleaned off paint and by rinsing with turpentine. A brush in which paint has dried up is ruined and shall on no account be used for painting work. The containers, when not in use, shall be closed, kept air tight and shall be kept at a place free from dust. When the paint has been used, the containers shall be washed with turpentine and wiped dry with soft clean cloth, so that they are clean & can be used again.

8.0 PRECAUTIONS:

9.0 All furnitures, lightings, fixtures, sanitary fittings, glazing, floors etc. shall be protected by covering and stains, smears, splashings, if any shall be removed and any damage done shall be made good by the contractor at his cost.

10 RATES: 10.1 Rates shall include cost of all labour and materials involved on all the operations described above and in the particular specifications given under the several items.

11.0 PAINTING PRIMING COAT ON WOOD SURFACES:

11.1 Primer

11.1.1 The primer for wood work, iron work or plastered surface shall be as specified in the description of the item.

11.1.2 Primer for Wood work / Iron & Steel / Plastered / Aluminium surfaces shall be as specified below:

Page 21 SN SURFACES PRIMER TO BE USED a Wood work (hard & soft wood): Pink conforming to I.S.3536- 1966 b Resinous wood and ply wood: Aluminium primer c Iron & Steel, Aluminium and galvanised Steel work: Zinc chromate primer conforming to I.S. 104-1962. d Plastered surfaces, cement brick work, Asbestos surfaces Cement Primer for oil bound distemper and paint:

11.1.3 The primer shall be ready mixed primer of approved brand and manufacture.

11.2 Preparation of surface :

11.2.1 Wood work: The wood work to be painted shall be dry and free from moisture.

11.2.1.1The surface shall be thoroughly cleaned. All unevenness shall be rubbed down smooth with sand paper and shall be well dusted. Knots, if any, shall be covered with preparation of red lead made by grinding red lead in water and mixing with strong glue sized and used hot. Appropriate filler material with same shade as paint shall be used where so desired by the Architects.

11.2.1.2 The surface treated for knotting shall be dry before painting is applied. After the priming coat is applied, the holes and indentation on the surface shall be stopped with glaziers putty or wood putty (for specifications for glaziers putty and wood putty- refer as mentioned here-in-before). Stopping shall not be done before the priming coat is applied as the wood will absorb the oil in the stopping and the latter is therefore liable to crack.

20.0 BEES WAXING OR POLISHING WITH READY MADE WAX POLISH :(NEW WORK):

Page 22 20.1 Materials: The polishing shall be done with bees waxing prepared locally or with ready made wax polish of approved brand and manufacture, as stipulated in the description of item.

b) Where bees waxing is to be prepared locally, the following specifications for the same shall apply:

Pure bees wax free from paraffin or stearing adulterants shall be used. Its specific gravity shall be 0.965 to 0.969 and melting point shall be 63o C. The polish shall be prepared from a mixture of bees wax, linseed oil, turpentine and in the ratio of 2: 1.5: 1: 0.5 by weight.

The bees wax and boiled linseed oil shall be heated over a slow fire. When the wax is completely dissolved, the mixture shall be cooled till it is just warm and turpentine and varnish added to it in the required proportions and the entire mixture shall be well stirred.

20.2 Preparation of surface: Preparation of surface will be as mentioned here-in-under para 32.20.2 with the exception that knotting, holes and cracks shall be stopped with a mixture of fine dust formed of the wood being treated, beaten up with sufficient bees wax to enhance cohesion. 20.3 Application: The polish shall be applied evenly with a clean soft pad of cotton cloth in such a way that the surface is completely and fully covered. The surface is then rubbed continuously for half an hour.

When the surface is quite dry, a second coat shall be applied in the same manner and rubbed continuously for one hour or until the surface is dry.

The final coat shall then be applied and rubbed for two hours (more if necessary) until the surface has assumed a uniform gloss and is dry showing no sign of stickiness.

The final polish depends largely on the amount of rubbing which should be continuous and with uniform pressure, with frequent changes in the direction

1 Other details: The specifications for painting (General) as mentioned here-in- before shall hold good as for as they are applicable.

2 FRENCH SPIRIT POLISHING: (ON NEW WORK WITH A COAT OF WOOD FILLER):

21.1 Polish: Pure varying from pale orange to lemon yellow colour, free from resin or dirt shall be dissolved in methylated spirit at the rate of 140 gm. of shellac to 1 litre of spirit. Suitable pigment shall be added to get the required shade. 21.2 Preparation of surface: The surface shall be cleaned. All unevenness shall be rubbed

Page 23 down smooth with sand paper and well dusted off. Knots if visible shall be covered with a preparation of red lead and glue size laid on while hot. Holes and indentations on the surface shall be stopped with glaziers putty. The surface shall then be given a coat of wood filler made by mixing whiting(ground chalk) in methylated spirit at the rate of 1.5 kg. of whiting per litre of spirit. The surface shall again be rubbed down perfectly smooth with glass paper and wiped clean.

21.3 Application: The number of coats of polish to be applied shall be as described in the Iem. A pad of woolen cloth covered by fine cloth shall be used to apply the polish. The pad shall be moistened with the polish and rubbed hard on the wood, in a series of overlapping circles applying the mixture sparingly but uniformly over the entire area to give an even level surface. A trace of linseed oil on the face of the pad facilitates this operation. The surface shall be allowed to dry and the remaining coats applied in the same way. To finish off, the pad shall be covered with a fresh piece of clean fine cotton cloth, slightly damped with methylated spirit and rubbed lightly and quickly with circular motions. The finished surface shall have a uniform texture and high gloss.

1 CONSUMPTION OF PAINT FOR DIFFERENT PAINTING ITEMS: 2 COVERAGE PER SQM ACHIEVED PER LITRE PAINT: (Note : Coverage per Kg is mentioned with respective item)

Sr. Brief Description of painting work Consumption No per10 sqm of net area 1 Oil Bound Distemper on plastered surfaces : a) Cement Primer (one coat). 0.91 litres. b) Two finishing coats. 1.60 kg. c) Three finishing coats. 2.40 kg.

2 Flat oil paint to plastered surfaces: a) Cement primer (one coat). 0.91 ltr. b) Cement primer (two coats). 1.82 ltrs.

c) Two finishing coats. 1.72 ltrs.

3 Acrylic Emulsion Paint: a) Cement primer (one coat). 0.91 ltr. b) Two finishing coats 0.87 ltr. c) Three finishing coats. 1.30 ltrs.

4 Cement Paint (old surfaces): a) Two coats on sand faced plastered surface. 4.10 kg.

Page 24 b) Two coats on rough cast plastered surface. 7.70 kg.

5 Cement Paint (New surfaces). a)Two coats on sand faced plastered 4.50 kg. b)Two coats on rough cast plastered 8.50 kg

6 Enamel Paint to wood/steel: a) Wood primer (one coat.) 0.90 ltr. b) Steel primer (one coat.) 0.75 ltr. c) Two finishing coats on wood. 1.40 ltrs. d) Two finishing coats on steel. 1.35 ltrs.

7 Flat Oil Paint to wood/steel work. a) Wood primer ( one coat.) 0.90 ltr. b) Steel primer (one coat.) 0.75 ltr. c) Two finishing coats on wood. 1.70 ltrs. d) Two finishing coats on steel. 1.70 ltrs.

8 External Painting with flat oil paint: a) Cement primer (one coat.) 1.00 ltr. b) Two finishing coats. 1.74 ltrs.

c) Two coats of enamel paint. 1.35 ltrs.

Sr. Name of Paint Area Area Area No. coverage coverage coverage for one For two per addl. coat (Old coats (Old coat work) work) 1 Synthetic enamel paint 14 sq.m. 8.5 sq.m. 18 sq.m. 2 Plastic emulsion paint 14 sq.m. 8.5 sq.m. 18 sq.m. 3 Oil Bound distemper 10 sq.m. 6.0 sq.m. 12 sq.m. 4 Dry distemper 10 sq.m. 6.5 sq.m. 12 sq.m.

per kg per kg per kg 5 White Wash : Note : Following things to be 5 sq.m.per 3.5 10 added in lime (i)Adhesive (DDL/SDL) -5% of kg of sq.m.per sq.m.per lime, (ii)Neel (Blue) - 3 gm per kg of lime, (iii) Lime kg of Lime kg of Lime Water - 5 kg of water per kg of lime

6 Cement based paint 4.5sq.m. 2 6

Page 25 per kg sq.m.perkg sq.m.perkg

7 Aluminium paint 20 sq.m. 12.5 sq.m. 28 sq.m. 8 Bitumen paint / Black Japan 14 sq.m. 14 sq.m. 28 sq.m. 9 Oil based putty as per manufacturer’s specification. + Red oxide metal primer 16 sq.m. 11 Cement primer 12 sq.m. 12 Wood primer 13 sq.m. 13 Wax polishing of new wood work with ready 20 sq.m. 20 sq.m. 20 sq.m. made polish per kg per kg per kg 14 French or spirit polish 10.5 sq.m. 15 Varnish 14 sq.m. 8.5 sq.m. 18 sq.m. 16 Requirement of paint per coat in Structural steel work on tonnage basis Truss and Lattice girder work - 4.5 litres per tonne. Plane Beam/plane girder work- 2.5 litres per tonne

RATES FOR ALL ITEMS OF WORK

The rates quoted by the Contractor for all items of work as described in the schedule of quantities and as shown in detailed drawings and shall be to the entire satisfaction of the Architect.

LIST OF APPROVED MAKES

General Specifications for Interior Works S.No. Material Make 1 7160 1976 BWP Marine Century, Mayur, Greenply, Anchor, Archid, Kenwood, plywood /Flexi Ply Western India. 2 Block board Century, Swastik, Kutty, Archid, Anchor. 3 Veneer Century, Marino, Archid 4 Laminate Archid, Formica, Silicon, Heritage 5 Hardwares Geze, Haffle, Hettich, Dorma, Dline 6 Paints Asian, Nerolac, Dulux, Pidilite. 7 Anchore/fastner, patch fittings Geze, Hilty. 8 Leather foam Bhor, royal touch, 9 Adhesives Pidilite, araldite. 10 Melamine polish Pidilite, Asian, Sheenlac, Burger. 11 Fabric Response, Zing, Sarom. 12 Aluminium Section Hindalco, Jindal 13 Metal screw Nettle fold, GKW. 14 Compactors Krompress, Godrej, Kompact

Page 26 15 Mirror, Glass Saint Gobain, AIS, Tata continental, Modi guard. 16 PU Asian, Burger, Pidilite 17 Foam Mody, Dunlop 18 Door Closure Dorma, Dline 19 Putty JK, Birla, Italian 20 MDF, HDF Bajaj Ergo, Novo pan, Heritage

Note:The shade/colour/texture/pattern of all the materials will be selected by the Architect / Employer and the samples shall be produce by the Contractor for selection.