P1 Product Specification Comparison Chart
LCR Meter
P6 6730/6731/6732 P8 6373/6374 Applications include resistors, capacitors, P10 6375/6376 Component inductors, oscillators, sensors, delay Tester 1 lines, wave filters and resonators.
HIPOT Tester P18 7600/7620/7621 The testing covers the insulating quality, current leakage, cross-slot HV coils, slot Safety Tester HASL, line hooking, line bending and 2 other QA problems.
Transformer Tester The application of the system includes P26 5235/5236/5237/5238 Transformer power source transformers, network Tester communications transformers and 3 wireness charge components.
4-Wire Cable Tester P36 8700 Applications include HDMI, USB cables, Cable Tester signal cables, type-C cables, cat-6 4 cables and all kind of wires.
Motor Stator Tester P42 6910
Multiple sets of objects can be tested simultaneously (depending on the coil Motor Tester turns of the product); applicable to 5 various types of motors.
Single-Phase Power Meter Modular design ensures easy Automatic maintenance and the programming P48 7110/7120 Testing environment is simple, easy to Equipment understand and equipped with powerful 6 testing capabilities.
High Precision Provide economic testing solutions 4-Wire PCB PCB Testing depending on the requirements of Tester Equipment the customers and satisfy most of the P58 9330 7 customers in their testing applications. P60 9310 Impedance Analyzer Precision Impedance Analyzer DC Bias Current Sourse P16 6210/6220/6240 P12 6377/6378/6379 P14 6630
Precision HIPOT Tester Impulse/Surge Tester P20 7630/7631 P22 7700/7710/7720 P24 7703/7713
Comprehensive Transformer P28 5435/5436/5437/5438 Testing Systems
P30 2 IN 1 6235+7620 P32 3 IN 1 6235+7721+6905 P34 4 IN 1 6235+6210+7721+6905
2-Wire Cable Tester
P38 8730 P40 8740
P44 6913/6917 Motor Armature Tester
P46 6920
LIPS Testing Power Switch/ LED Universal System Power Testing System Function Tester
P51 PT-9000 P54 PT-9200/PT-9300 P56 PT-960F
Fixture & Accessory P62 Component Tester Safty Tester Transformer Tester
Fixture & 8Accessory 9330 series High Precision PCB/FPCB Test System
Test point : Max. 4096 points Hight voltage open test : Max. DC300V Stable double cylinders press system Open test for impedance of nearby nets 4-wire test / 2-wire test in one testing
7120 series Single-Phase Power Meter
Wide range 0.001W ~ 16kW AC / DC Dual amp / watt-hour meter 50 levels harmonic wave analysis capability
7630 series HIPOT Tester 2 / 9 Channels Built-in discharge circuit True RMS measurement circuit Programmable PLC remote control interface
6630 series Precision Impedance Analyzer
DC, 10Hz ~ 3/5/10/20/30MHz Basic Accuracy ±0.08% Ultra-high measuring speed : Max. <5mS Dielectric permittivity measurement 2016 NEW CONTINUED TO IMPROVE PRODUCTS Component Tester Comparison Chart
Item LCR Meter Impedance Analyzer
Model 6370 6371 6372 6373 6374 6375 6376 6377 6378 6379 6630
Test Freq. 100-20k 100-100k 100-200k 20-20k 20-100k 200-200k 20-500k 20-1M 20-5M 20-10M 10-30M (Hz)
Point of 372 388 390 Continuity Freq.
AC Drive 0.05V/0.1V 10mV-2Vrms (1mVrms steps) Level /0.25V/0.5V/1V
Basic ± 0.1% ± 0.08% Accuracy
Multi Step - - - ● ● ● ● ● ● ● ●
PC Link ● ● ● ● ● ● ● ● ● ● ●
DC Bias - - - - - 6210 / 6220 / 6240 -
DC Bias - - - - - 200k 500k 1M 3M 3M - Freq. (Hz)
Max. - - - - - 60A / 120A / 320A - Current
Constant Power - - - - - ● ● ● ● ● - Output Current Switch - - - - - ● ● ● ● ● - Function DC Bias Current ------● ● ● - Sweep Freq. Graphic Freq. ------ACV Mode ACV ACI
Temp. ------Analysis ● ● ●
Display 320*240 320*240 800*480 240*64 (LCD) 3.5" 5.7" 7.0" TFT
www.microtest.com.tw 1 HIPOT Tester Comparison Chart
Item / Model 7600 7620 7621 7630 7631 Channel 2 8 8 2 9 AC Output Voltage 0.1-5kV AC Frequency 50/60Hz AC Current 0.001-10mA 0.001-25mA DC Output Voltage 0.1-6kV DC Current 0.001-5mA Measuring Time 0.1-99 Sec 0.1-999 Sec Ramp Time 0.1-99 Sec 0.1-10 Sec Dwell Time Auto Adjust IR Output Voltage 0.1-1kV 0.01-1kV IR Range 1-9999MΩ 1-12000MΩ ARC Detection ● ● ● ● ● O/S Correction - - ● - - Remote Control ● ● ● ● ● PC Link - - - ● ●
Impulse/Surge Tester Comparison Chart
Item / Model 7700 7710 7720 7703 7713 Channel 2 2 8 2 2 Low Inductance Test ● ● ● ● ● Impulse Voltage (V) 200-5000 200-10000 200-5000 200-5000 200-10000 Non-Destructive Analysis ● ● ● ● ● Output Frequency Auto Adjust ALC Function ● ● ● ● ● Lowest Inductance 50 100 50 0.5 0.5 (µH) Waveform Analysis ● ● ● ● ● HARM Analysis - - - ● ● HFLT Analysis - - - ● ● GO/NG Adjust ● ● ● ● ● Language English / Chinese Memory (set) 200 200 80 200 200 Auto Voltage Learn - - - ● ●
2 Transformer Tester Comparison Chart
Item / Model 5235 5236 5237 5238 5435 5436 5437 5438
Channel 20 48
Frequency (Hz) 20-200k 20-500k 20-1M 20-200k 20-200k 20-500k 20-1M 50-200k
AC Drive Level 10mV-2V
Point of Freq. Continuity
Basic Accuracy ± 0.1%
IZI, R, X 0.01mΩ-100mΩ
lYl, G, B 0.0001nS-1000S
C 0.01pF-1F
L 0.1nH-9999.99H
D 0.0001-9.9999
Q 0.1-999.9
DCR ● ● ● ● ● ● ● ●
O/S Detection ● ● ● ● ● ● ● ●
Turn Ratio ● ● ● ● ● ● ● ●
PC Link ● ● ● ● ● ● ● ●
Meter Mode - - ● ● - - ● ●
Display (LCD) 320*240
www.microtest.com.tw 3 Cable Tester Comparison Chart
Item 4-Wire 2-Wire
Model 8700 8730N 8730NA 8730FA 8740N 8740NA 8740FA
Test Point 64/128/256 128/256 128/256/512 128/256
Basic ±1.0% ±5.0% Accuracy
DC Output 50-1500V 100-1000V 100-1500V 50-1000V 50-1500V Voltage
AC Output 50-1000V - 100-700V 100-1000V - 100-700V 100-1000V Voltage
AC Leakage 0.01mA-5mA Current
Language English / Chinese
Insulation 0.1-1500MΩ 1-1000 MΩ 1-1000 MΩ Test
Resistance 0.1mΩ-10MΩ 10mΩ-10MΩ 10mΩ-1MΩ Test
Capacitance 10p-1µF Test
Conductance 0.1mΩ-50Ω 10mΩ-50Ω Test
Instant Conductance ● ● ● ● ● ● ●
Instant O/S ● ● ● ● ● ● ●
Unilateral - Test ● ● ● ● ● ●
Multi Step Test ● ● ● ● ● ● ●
Meter Mode ● ------
Scan Auto / Continue / Manual Function
PC Link ● - - - ● ● ●
4 Motor Tester Comparison Chart
Motor Stator Tester Motor Stator Tester Motor Armature Tester Item / Model MT-6910 MT-6913 / MT-6917 MT-6920
DCR Test Range 0.1mΩ-100kΩ 0.1mΩ-100kΩ 0.1mΩ-100kΩ
DCR Accuracy ± (0.2%±1mΩ)
Measuring Mode 4-Wire
Resistance Welding - - ●
Channel 8 13/17 24/48
AC HI-POT 0.1-5kV 0.1-3kV
AC Frequency 50/60Hz
AC Current 0.001-10mA
DC HI-POT 0.1-6kV 0.1-3kV
DC Current 0.001-5mA
Measuring Time 0.1-99Sec
Ramp Time 0.1-99Sec
Dwell Time Auto Adjust
DC Output for IR 0.1-1kV
IR Range 1-9999MΩ
ARC Detection ● ● ● Low-Energy Pulse Test ● ● ● Non-Destroyable Analyzer ● ● ●
HI-POT Voltage 5kV 3kV
ALC Function ● ● ●
Low Inductance Test 50µH
Waveform Comparison ● ● ● GO/NO GO Judgement ● ● ● PC Link ● ● ●
www.microtest.com.tw 5 Component 6370/6371/6372 1Tester LCR Meter
RS232 Remote GPIB Option
Basic accuracy up to 0.1% LCR Meters are all compatible with convenient and efficient Meter Link Software Overall Compact design, good for production line use
Key Feature User-friendly interface, allows for production line personnel to operate efficiently
Standard Optional Power cord RS-232 Cable User manual CD F423502 Accessory BNC Kelvin Clips (F423501) F423504 F423905 F420001
Measuring Range
IZI, R, X 0.1mΩ - 100MΩ Q 0.1 - 9999.9
lYl, G, B 10nS - 1000S DCR 0.1mΩ - 100MΩ
Cs Cp 0.01pF - >1F Δ% -999.99% - 999.99%
Ls Lp 0.01nH - 100kH θ -180° - +180°
D 0.00001 - 9.9999
6 LCR Meter Component Tester
Specification 6370 100Hz - 20kHz 372 points
Operating Frequency 6371 100Hz - 100kHz 388 points
6372 100Hz - 200kHz 390 points Component TesterComponent
Basic Accuracy ± 0.1%
AC Drive Level 0.05V、0.1V、0.25V、0.5V、1V
DC Drive Level 0.5V
Output Impedance 100Ω
Frequency Resolution 5 Digits, ± 0.01%
AC test speed (Fast) 5 times/sec DC test speed (Fast) 5 times/sec
AC test speed (Medium) 3 times/sec DC test speed (Medium) 3 times/sec
AC test speed (Slow) 2 times/sec DC test speed (Slow) 2 times/sec
Bias Voltage 2V General Equivalent Circuit Series / Parallel
Mathematical Mode Absolute / Percentage
Test Range Automatic / Lock
Indicator Pass / Fail / Bias LED / Built-in speaker
Output Terminal BNC Connector
Safety EN61010-1
Open Circuit / Short Circuit: Avoid the misreading caused by the stray Calibration capacitance from kelvin clips and fixtures
Voltage 90-132Vac or 198-264Vac (selectable) Power Supply Frequency 47-63Hz
Display 240*64 dot-matrix display
Interface RS-232、GPIB (option)、Handler (option)
Flash Memory Storage of 127 rewritable data sets
Operation Auto、Manual、Remote Control、RS-232、GPIB (option)
Environment Temperature : 10 ~ 40℃ / Humidity : 20 ~ 90%
Dimension (W*H*D) 335x100x322 mm
Weight 5 Kg
www.microtest.com.tw 7 Component 6373/6374 1Tester LCR Meter
RS232 GPIB Handler Option Option
Basic accuracy up to 0.1% Synchronous tests with multiple parameter settings Measurement of wide range of functions: Freq. to 5 Digits
Key Feature LCR Meters are all compatible with convenient and efficient Meter Link Software
Standard Optional Power Cord Meter Link Software User Manual CD RS-232 Cable
Accessory BNC Kelvin Clips (F423501) Handler Box F423502 F423504 F423905 F420001
Measuring Range
IZI, R, X 0.1mΩ - 100MΩ Q 0.1 - 9999.9
lYl, G, B 10nS - 1000S DCR 0.1mΩ - 100MΩ
Cs Cp 0.01pF - >1F Δ% -999.99% - 999.99%
Ls Lp 0.01nH - 100kH θ -180° - +180°
D 0.00001 - 9.9999
8 LCR Meter Component Tester Specification 6373 20Hz - 20kHz Operating Frequency 6374 20Hz - 100kHz
Point of Freqency Continuity TesterComponent
Basic Accuracy ± 0.1%
AC Drive Level 10mV-2Vrms (1mVrms steps)
DC Drive Level 0.01V-2V
Output Impedance 100Ω
Frequency Resolution 5 Digits, ±0.01%
AC test speed (Max.) 75mS AC test speed (Max.) 30mS
AC test speed (Fast) 150mS AC test speed (Fast) 60mS
AC test speed (Medium) 300mS AC test speed (Medium) 120mS
AC test speed (Slow) 600mS AC test speed (Slow) 500mS General Equivalent Circuit Series / Parallel
Test Range Automatic / Lock
Mathematical Mode Absolute / Percentage
Indicator Pass / Fail / Bias LED / Built-in speaker
Output Terminal BNC Connector Safety EN61010-1
Open Circuit / Short Circuit: Avoid the misreading caused by the stray Calibration capacitance from kelvin clips and fixtures
When the power is turned off or encounter a power outage, all the data will Auto-save function be saved automatically and recovered when tester system is switched on again
Voltage 90-132Vac or 198-264Vac (selectable) Power Supply Frequency 47-63Hz
Display 320*240 dot-matrix display
Interface RS-232、GPIB (option)、Handler (option)
Flash Memory 64 groups of Multi-steps setting (Each group contains up to 30 steps)
Operation Auto、Manual、RS-232、GPIB (option)、Handler (option)
Environment Temperature : 10 ~ 40℃ / Humidity : 20 ~ 90%
Dimension (W*H*D) 335x100x322 mm Weight 5 Kg
www.microtest.com.tw 9 Component 6375/6376 1Tester LCR Meter
RS232 Remote GPIB Option
Basic accuracy up to 0.1% Synchronous tests with multiple parameter settings Measurement of wide range of functions: Freq. to 5 Digits
Key Feature Collocating DC Bias to progressing current scanning analysis Fixture design capabilities, Specific customized services for clients LCR Meters are all compatible with convenient and efficient Meter Link Software
Standard Optional Power Cord Meter Link Software User Manual CD RS-232 Cable Accessory BNC Kelvin Clips (F423501) Handler Box SMD Fixture (F423905) DIP Fixture (F423503)
Measuring Range
IZI, R, X 0.1mΩ - 100MΩ Q 0.1 - 9999.9
lYl, G, B 10nS - 1000S DCR 0.1mΩ - 100MΩ
Cs Cp 0.01pF - >1F Δ% -999.99% - 999.99%
Ls Lp 0.01nH - 100kH θ -180° - +180°
D 0.00001 - 9.9999
10 LCR Meter Component Tester Specification 6375 20Hz - 200kHz Operating Frequency 6376 20Hz - 500kHz
Point of Freqency Continuity Basic Accuracy ± 0.1% TesterComponent
AC Drive Level 10mV-2Vrms (1mVrms steps)
DC Drive Level 0.01V-2V
Output Impedance 100Ω
Frequency Resolution 5 Digits, ± 0.01%
AC test speed (Max.) 75mS DC test speed (Max.) 20mS
AC test speed (Fast) 150mS DC test speed (Fast)t 60mS
AC test speed (Medium) 300mS DC test speed (Medium) 120mS
AC test speed (Slow) 600mS DC est speed (Slow) 500mS
Bias Voltage 2V General Equivalent Circuit Series / Parallel
Test Range Automatic / Lock
Mathematical Mode Absolute / Percentage
Indicator Pass / Fail / Bias LED / Built-in speaker
Output Terminal BNC Connector
Open Circuit / Short Circuit: Avoid the misreading caused by the stray Calibration capacitance from kelvin clips and fixtures
When the power is turned off or encounter a power outage, all the data will Auto-save function be saved automatically and recovered when tester system is switched on again
Safety EN61010-1
Voltage 90-132Vac or 198-264Vac (selectable) Power Supply Frequency 47-63Hz
Display 320*240 dot-matrix display
Interface RS-232、GPIB (option)、Handler (option)
Flash Memory 64 groups of Multi-steps setting (Each group contains up to 30 steps)
Operation Auto、Manual、RS-232、GPIB (option)、Handler (option)
Environment Temperature : 10 ~ 40℃ / Humidity : 20 ~ 90%
Dimension (W*H*D) 337x145x522 mm Weight 6.5 Kg
www.microtest.com.tw 11 Component 1Tester Impedance Analyzer 6377/6378/6379
RS232 GPIB Handler Option Option
Basic accuracy up to 0.1% Synchronous tests with multiple parameter settings Graphic scanning analysis function
Key Feature Measurement of wide range of functions: Freq. to 5 Digits Collocating DC Bias to progressing current scanning analysis Fixture design capabilities, Specific customized services for clients
Standard Optional Power Cord Meter Link Software User Manual CD RS-232 Cable Accessory BNC Kelvin Clips (F423901) Handler Box SMD Fixture (F423905) DIP Fixture (F423503)
Measuring Range
IZI, R, X 0.1mΩ - 100MΩ Q 0.1 - 9999.9
lYl, G, B 10nS - 1000S DCR 0.1mΩ - 100MΩ
Cs Cp 0.01pF - >1F Δ% -999.99% - 999.99%
Ls Lp 0.01nH - 100kH θ -180° - +180°
D 0.00001 - 9.9999
12 Impedance Analyzer Component Tester Specification 6377 20Hz - 1MHz
Operating Frequency 6378 20Hz - 5MHz
6379 20Hz - 10MHz Component TesterComponent
Point of Frequency Continuity
Basic Accuracy ± 0.1%
AC Drive Level 10mV-2Vrms (1mVrms steps)
DC Drive Level 0.01V-2V Output Impedance 100Ω
Frequency Resolution 5 Digits, ±0.01%
AC test speed (Max.) 75mS DC test speed (Max.) 30mS
AC test speed (Fast) 150mS DC test speed (Fast)t 60mS
AC test speed (Medium) 300mS DC test speed (Medium) 120mS
AC test speed (Slow) 600mS DC est speed (Slow) 500mS
Bias Voltage 2V General Equivalent Circuit Series / Parallel
Test Range Automatic / Lock
Mathematical Mode Absolute / Percentage
Indicator Pass / Fail / Bias LED / Built-in speaker
Output Terminal BNC Connector
Open Circuit / Short Circuit: Avoid the misreading caused by the stray Calibration capacitance from kelvin clips and fixtures
When the power is turned off or encounter a power outage, all the data will Auto-save function be saved automatically and recovered when tester system is switched on again
Safety EN61010-1
Voltage 90-132Vac or 198-264Vac (selectable) Power Supply Frequency 47-63Hz
Display 320*240 dot-matrix display
Interface RS-232、GPIB (option)、Handler (option)
Flash Memory 64 groups of Multi-steps setting (Each group contains up to 30 steps)
Operation Auto、Manual、RS-232、GPIB (option)、Handler (option)
Environment Temperature : 10 ~ 40℃ / Humidity : 20 ~ 90%
Dimension (W*H*D) 337x145x522 mm Weight 6.5 Kg
www.microtest.com.tw 13 Component 1Tester Precision Impedance Analyzer NEW 6630
RS232 Remote GPIB Option
Basic accuracy up to ±0.08% Operating frequency range: DC, 10Hz ~ 3/5/10/20/30MHz Signal source grade: 10mV ~ 2V / 200µA ~ 20mA Ultra-high measuring speed Key Feature Dielectric permittivity measurement Function Electric meter mode, multistep list mode, scan & analyze mode Comparator function and Handler BIN classification function PC connection data analysis software is available optionally
Standard Optional Power Cord Meter Link Software User Manual CD RS-232 Cable Accessory DIP Fixture (FX-0000C6) SMD Fixture (F423905) Dielectric Permittivity Fixture
Measuring Range
IZI, R, X ± 0.000mΩ - 9999.99MΩ D ± 0.00000 - 9.99999
lYl, G, B ± 0.00000µS - 999.999kS Q ± 0.00 - 999999
C ± 0.00000pF - 999.999F θ ± 0.000° - 180.000°
L ± 0.00nH - 999.999kH Δ% ± 0.000 % - 999.999 %
DCR 0.00mΩ - 100MΩ
14 Impedance Analyzer Component Tester Specification 6630-03 10Hz - 3MHz
6630-05 10Hz - 5MHz
6630-10 10Hz - 10MHz
Operating Frequency TesterComponent 6630-20 10Hz - 20MHz
6630-30 10Hz - 30MHz
Resolution 100mHz, 6 Digits, ± 0.01%
Basic Accuracy ± 0.08%
Signal Voltage Level 10mV - 2Vrms
Voltage Resolution 1mV
ALC OFF:10% * Voltage ±2mV Accuracy ALC ON:6% * Voltage ±2mV AC Drive Level Signal Current Level 200µA - 20mArms
Current Resolution 10µA
ALC OFF:10% * Current ± 20µA Accuracy ALC ON:6% * Current ± 20µA
Test Speed (Max.) < 5mS
Output Impedance 25Ω / 100Ω (selectable)
Parameters |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C、 Vdc-Idc、ESR
Measurement Mode Meter mode / Graphic mode / Multi-steps mode
Calibration Open Circuit / Short Circuit / Load Calibration
Equivalent Circuit Series / Parallel
Test Range Automatic / Lock
Mathematical Mode Absolute / Percentage
Multi-steps Mode 50 groups of Multi-steps setting (Each group contains up to 15 steps)
PC Link / CPK Optional
Flash Memory 100 groups of LCR setting documents
USB LCR setting documents、BMP graphics、Test result data
I/O Interface Handler
Interface Serial Interface USB、RS232
Parallel Interface GPIB
Display 7.0”TFT, 800*480 Color Screen
Environment Temperature : 10 ~ 40℃ / Humidity : ≦ 90%RH
Voltage 90-264Vac Power Supply Frequency 47-63Hz
Power Consumption Maximum 30W
Dimension (W*H*D) 344x145x343 mm Weight 3 Kg
www.microtest.com.tw 15 Component Tester DC Bias Current Source 1 6210/6220/6240
RS232
Current and frequency graphic scanning analysis Temperature-rising scan function - solve the problems of overheating a DUT to burn DCR Measurement function
Key Feature Long-term consecutive maximum power output Interchangeable bi-direction current function Scalable current output up to 120A / 320A (6220 / 6240) Innovative strengthen protection device Auto-adjust maximum voltage output according to current output Direct Handler interfaces control through LCR power meter
16 DC Bias Current Source Component Tester Specification DC Bias Model 6210 6220 6240
Output Current 0.000A - 10.000A 0.000A - 20.000A 0.000A - 40.000A
0.000A - 1.000A 1%+5mA TesterComponent
Accuracy 1.001A - 5.000A 2%
5.001A - 20.000A 3%
Frequency 20Hz - 3MHz
Power Consumption 320W max.
LCR Meter Model 6375 6376 6377 6378 6379 6577 LCR Meter with DC Bias Meter Mode ● ● ● ● ● ●
LCR Frequency (Hz) 200k 500k 1M 5M 10M 1M
DC Bias Model 6210 / 6220 6240
DC Bias Freq. (Hz) 200k 500k 1M 3M 3M 1M
Output Current (Max.) 60AMP / 120AMP 320AMP
Constant Power ● ● ● ● ● ● Output
Current Switch ● ● ● ● ● ●
DC Resistance ● ● ● ● ● ●
Graphic Mode - - ● ● ● ●
Temprature Analysis ● ● ● ● ● ● General Voltage 88-264Vac Power Supply Frequency 47-63Hz
Interface RS-232、Handler (option)
Operation Auto、Manual、RS-232、GPIB (option)
Environment Temperature : 10 ~ 40℃ / Humidity : 20 ~ 90%
Dimension W*H*D 337x145x522 mm
Weight 15 Kg
www.microtest.com.tw 17 7600/7620/7621 Safty2 Tester HI-POT Tester
RS232 Remote
8 Channels (7620 / 7621) Connected to Impulse Winding Tester Graphics LCD window AC high voltage, DC high voltage and Built-in programmable PLC remote insulation test control interface Ramp time setting Key Feature Open/short detect function (7621) Built-in RS-232 interface
Standard Optional Power cord RS-232 Cable User manual CD Scan Box (F7620) Accessory HV Test Cable Remote Cable D-Sub Footswitch (F760001)
Measuring Range
AC Withstand 100V - 5000V Insulation Resistance 100V - 1000Vdc
DC Withstand 100V - 6000V Arcing 1 - 9
18 HIPOT Tester Safty Tester Specification Measuring Item Range Resolution Accuracy
AC Output Voltage 100V-5000V 10 ±(3% of setting + 5V)
AC Output Frequency 50 / 60Hz
AC Upper Threshold (mA) 0.001-10 0.001 ±3% Safty Tester
AC Lower Threshold (mA) 0-9.999 0.001 ±3%
AC Measuring Time / 0.1-99.9s 0.1 Ramp Time
AC Arcing 1-9
DC Output Voltage 100V-6000V 10 ±(3% of setting + 5V)
DC Upper Threshold (mA) 0.001-5 0.001 ±3%
DC Lower Threshold (mA) 0-4.999 0.001 ±3%
DC Measuring Time / 0.1-99.9s 0.1 Ramp Time
DC Arcing 1-9
IR Output Voltage 100-1000Vdc 10 ±(3% of setting + 5V)
IR Upper Threshold (MΩ) 1-9999 1 100-500V, 1-1000MΩ (±5%) 500-1000V, 10-5000MΩ (±5%) IR Lower Threshold (MΩ) 0-9998 1 1000V, 10-9999MΩ (±5%)
IR Measuring Time / 0.1-99.9s 0.1 Ramp Time General Voltage 115 / 230Vac ± 15% Power Supply Frequency 50 / 60Hz ± 5%
Display 128*64 dot-matrix display
Interface RS-232、Remote Control
PLC Remote Control Test、Abort
PLC Output Signal Pass / Fail / HV output
Flash Memory 30 sets
Operation Manual、Remote Trigger
Environment Temperature : 5 ~ 40℃ / Humidity : 0 ~ 80%
365x145x396 mm……………7600 Dimension (W*H*D) 435x145x466 mm……………7620/7621
14 Kg ……………7600 Weight 15 Kg ……………7620/7621
www.microtest.com.tw 19 NEW Safty2 Tester Precision HI-POT Tester 7630/7631
RS232 Remote USB
9 Channels(7631) AC/DC hipot and insulation test Graphic LCD Arcing detection Built-in programmable PLC remote Built-in RS-232 and USB Device control interface
Key Feature Adjustable ramp time Built-in discharge circuit True RMS measurement circuit
Standard Optional Power cord RS-232 Cable User manual CD Scan Box (F7620)
Accessory HV Test Cable Remote Cable D-Sub Footswitch (F760001) 20 Channels Expansion Box
Measuring Range
AC Withstand 10V - 5000V Insulation Resistance 10V - 1000Vdc
DC Withstand 10V - 6000V Arcing 0 - 20
20 HIPOT Tester Safty Tester Specification Measuring Item Range Resolution Accuracy
AC Output Voltage 10V-5000V 1 ±(3% of setting + 5V)
AC Output Frequency 50 / 60Hz
AC Upper Threshold (mA) 0.001-25 0.001 ±3% Safty Tester
AC Lower Threshold (mA) 0-24.99 0.001 ±3%
AC Measuring Time / 0.1-999s / 0.1-10s 0.1 Ramp Time
AC Arcing 0-20
DC Output Voltage 10V-6000V 1 ±(3% of setting + 5V)
DC Upper Threshold (mA) 0.001-5 0.001 ±3%
DC Lower Threshold (mA) 0-4.99 0.001 ±3%
DC Measuring Time / 0.1-999s / 0.1-10s 0.1 Ramp Time
DC Arcing 0-5
IR Output Voltage 10-1000Vdc 1 ±(3% of setting + 5V)
IR Upper Threshold (MΩ) 1-12000 1 100-500V, 1-1000MΩ (±5%) 500-1000V, 2-12000MΩ (±5%) IR Lower Threshold (MΩ) 0-11999 1
IR Measuring Time / 0.1-999s / 0.1-10s 0.1 Ramp Time General Voltage 90~264Vac Power Supply Frequency 50 / 60Hz ± 5%
Display 480*272, 4.3" TFT LCD
Interface RS-232、PLC Remote、USB Host、USB Device、EXT IO
PLC Remote Control Test、Abort
PLC Output Signal Pass / Fail / HV output / Testing
Flash Memory 30 sets
Multi-steps Mode 16 steps
Environment Temperature : 5 ~ 40℃ / Humidity : 0 ~ 80%
365x145x430 mm……………7630 Dimension (W*H*D) 435x145x500 mm……………7631
14 Kg ……………7630 Weight 15 Kg ……………7631
www.microtest.com.tw 21 Safty Tester Impulse/Surge Tester 2 7700/7710/7720
RS232 Remote GPIB Option
Lowe power pulses test function 8 Channels (7720) Low power non-destructive test Multiple winding test function Automatic Level Control Function Provide statistic and print functions Measure voltage up to 10,000V (7710)
Key Feature Waveform comparison
Standard Optional Power cord PC Link Software User manual CD RS-232 Cable Accessory HV Test Cable Remote Cable D-Sub Footswitch
Measuring Item
Inductance Waveform comparison
Area comparison Corona
Total Area Flutter
22 Safty Tester 23 www.microtest.com.tw Impulse/Surge Tester Safty Tester Safty Tester Impulse/Surge / Humidity : 20 ~ 90% ℃ Remote Control 、 Print Port 、 Manual 、 435x145x522 mm……………7700/7710 435x190x522 mm……………7720 8 Kg ……………7700/7710 9 Kg ……………7720 Temperature : 10 ~ 40 Temperature 200 sets Auto 98 ~ 132Vac or 192 ~ 264Vac 98 ~ 132Vac 320*240 dot-matrix display RS-232 2 Channels 2 Channels 8 Channels 200V ~ 5000V (programmable) 200V ~ 10000V (programmable) ±2% 50mS Dimension (W*H*D) Weight Environment Flash Memory Operation Power Supply Display Interface 7710 7720 Voltage 7700/7720 Impluse 7710 Impluse Voltage Accuracy Impulse Voltage Measuring Time 7700
Specification General Safty2 Tester Impulse/Surge Tester 7703/7713
RS232 Remote
High-frequency harmonics analysis Measure voltage up to 10,000V (7713) Low power non-destructive test Provide statistic and print functions Automatic Level Control Function High-frequency noise signal analysis
Key Feature Waveform comparison Auto voltage Learn function Lowest inductance to 0.5µH
Standard Optional Power cord PC Link Software User manual CD RS-232 Cable
Accessory HV Test Cable Remote Cable D-Sub Footswitch
Measuring Item
HARM Analysis Waveform comparison
HFLT Analysis Corona
Total Area Flutter
Area comparison
24 Safty Tester 25 www.microtest.com.tw Impulse/Surge Tester Safty Tester Safty Tester Impulse/Surge / Humidity : 20 ~ 90% ℃ Remote Control 、 Print port 、 Manual 、 435x145x522 mm 8 Kg Temperature : 10 ~ 40 Temperature 200 sets Auto 98 ~ 132Vac or 192 ~ 264Vac 98 ~ 132Vac 320*240 dot-matrix display RS-232 2 Channels 2 Channels 200V ~ 5000V (programmable) 200V ~ 10000V (programmable) 0.5µH ±2% 50mS test waveforms The comparison between standard and indicator lights / Screen Pass / Fail / HV output LED red-green Display / Sound Dimension (W*H*D) Weight Environment Flash Memory Operation Power Supply Display Interface 7713 7703 Impulse Voltage 7713 Impulse Voltage Value Lowest Inductance Accuracy Impulse Voltage Measuring Time Measuring Mode Indicator 7703
Specification General 7703/7713 Transformer Transformer Tester Tester 3 5235/5236/5237/5238
RS232 Handler USB Option Option
Basic Accuracy up to 0.1% Support computer software connection and advanced software editing function Innovative fixture zero-setting function
Key Feature Able to test 30 items per second under fastest test speed Optional 100mA DC Bias / Meter Mode function (5237/5238)
Standard Optional Power cord Transformer Test Link Software User manual CD RS-232 Cable
Accessory Transformer Scan Box (F5220) Handler Box D-Sub Footswitch 5237/5238 BNC Kevin Clips (F423501) General Power Supply 90Vac ~ 125Vac or 190Vac ~ 250Vac / 48Hz ~ 62Hz
Display 320*240 dot-matrix display
Interface RS-232、Handler (option)、USB (option)
Flash Memory 64 Sets
Operation Auto、Manual、Remote Trigger
Environment Temperature : 10 ~ 40℃ / Humidity : 20 ~ 90%
Dimension (W*H*D) 365x145x396 mm
Weight 9 Kg
26 Comprehensive Test Transformer Tester
Measuring Range
Item Range Basic Accuracy Test Speed
L, LK 0.1nH - 9999.99H 0.1% 75mS
C 0.00001pF - 999.99mF 0.1% 75mS
Q, D 0.00001 - 99999 0.0005 75mS Transformer Tester Z, X, R 0.00001Ω - 99.9999MΩ 0.1% 75mS
Y 0.01nS - 99.9999S 0.1% 75mS
θ -180° - +180° 0.03° 75mS
DCR 0.01mΩ - 99.999MΩ 0.1% 25mS
Turn 0.01 - 99999.99 turns 0.5% 75mS
Pin-Short 12 pairs, between pin to pin - 25mS Specification 5235 20Hz-200kHz
5236 20Hz-500kHz Operating Frequency 5237 20Hz-1MHz (with Meter Mode function)
5238 20Hz-200kHz (with Meter Mode function)
Turn Ratio Frequency 50Hz-200kHz (10Vac Max.)
Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、 Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Parameters Resistance (ACR)、Quality Factor (Q)、Phase angle(Ø)、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit
Basic Accuracy ±0.1%
Output Impedance 100Ω
Frequency Trimming 5 Digits Resolution
Frequency Output ±0.01% Accuracy
Channel 20
Equivalent Circuit Series / Parallel
Mathematical Mode Absolute / Percentage
Calibration Open Circuit / Short Circuit / Load Calibration
www.microtest.com.tw 27 Transformer Transformer Tester 3Tester 5435/5436/5437/5438
RS232 Handler USB Option Option
Basic Accuracy up to 0.1% Support computer software connection and advanced software editing function Support open/short circuit calibration function
Key Feature Test 30 items per second, elevate productivity significantly through auto-scan function Paired with a 48-pin fixture for multi-pin network communication transforme Optional 100mA DC Bias / Meter Mode function (5437/5438)
Standard Optional Power cord Transformer Test Link Software User manual CD RS-232 Cable
Accessory 48 Channels Scan Box (F5248) Handler Box D-Sub Footswitch 5437/5438 BNC Kevin Clips (F423501) General Power Supply 90Vac ~ 125Vac or 190Vac ~ 250Vac / 48Hz ~ 62Hz
Display 320*240 dot-matrix display
Interface RS-232、Handler (option)、USB (option)
Flash Memory 60 Sets
Operation Auto、Manual、Remote Trigger
Environment Temperature : 10 ~ 40℃ / Humidity : 20 ~ 90%
Dimension (W*H*D) 365x145x396 mm
Weight 9 Kg
28 Comprehensive Test Transformer Tester
Measuring Range
Item Range Basic Accuracy Test Speed
L, LK 0.1nH - 9999.99H 0.1% 75mS
C 0.00001pF - 999.99mF 0.1% 75mS
Q, D 0.00001 - 99999 0.0005 75mS Transformer Tester Z, X, R 0.00001Ω - 99.9999MΩ 0.1% 75mS
Y 0.01nS - 99.9999S 0.1% 75mS
θ -180° - +180° 0.03° 75mS
DCR 0.01mΩ - 99.999MΩ 0.1% 25mS
Turn 0.01 - 99999.99 turns 0.5% 75mS
Pin-Short 12 pairs, between pin to pin - 25mS Specification 5435 20Hz-200kHz
5436 20Hz-500kHz Operating Frequency 5437 20Hz-1MHz (with Meter Mode function)
5438 20Hz-200kHz (with Meter Mode function)
Turn Ratio Frequency 50Hz-200kHz (10Vac Max.)
Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、 Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Parameters Resistance (ACR)、Quality Factor (Q)、Phase angle(Ø)、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit
Basic Accuracy ±0.1%
Output Impedance 100Ω
Frequency Trimming 5 Digits Resolution
Frequency Output ±0.01% Accuracy
Channel 48
Equivalent Circuit Series / Parallel
Mathematical Mode Absolute / Percentage
Calibration Open Circuit / Short Circuit / Load Calibration
www.microtest.com.tw 29 Transformer 2-in-1 Transformer Tester Tester 3 6235+7620
RS232 Remote
6235 7620 Basic precision up to 0.1% 8-port scan test Test frequency up to 1MHz Test items include (AC Withstand, DC Synchronous tests with multiple Withstand, Insulation Resistance) Key Feature parameter settings Rise time setting Optional Meter Mode function User-friendly interface, easy to High accuracy and stability operate
Standard Optional Power cord PC Link Software User manual CD RS-232 Cable
Accessory HV Test Cable Scan Box (F7721) D-Sub Footswitch Dual Scan Box (F7721-D) Remote Cable 24V Switch Power Supplier General Transformer Tester HI-POT Tester
6235 6236 6237 7620 Max. Frequency Output Voltage
AC 100V - 5kV
200kHz 500kHz 1MHz DC 100V - 6kV
IR 100V - 1kV
30 Comprehensive Test Transformer Tester 6235 Transformer Tester Parameters
Turn Ratio, Phase, L, Q, Leakage L, Balance, ACR, C, D, X, Y, DCR, Pin-Short
Measuring Range
L, LK 0.1nH - 9999.99H
C 0.00001pF - 999.99mF
Q, D 0.00001 - 99999 Transformer Tester Z, X, R 0.00001Ω - 99.9999MΩ
Y 0.01nS - 99.9999S
θ -180° - +180°
DCR 0.01mΩ - 99.999MΩ
Turn Ratio 0.01 - 99999.99 turns
Pin-Short 12 pairs, between pin to pin
General
Flash Memory 64 Files
Display 320*240 dot-matrix display
Voltage 90 ~ 125Vac or 190 ~ 250Vac Power Supply Frequency 48 ~ 62Hz
Dimension (W*H*D) 435x145x522 mm
Weight 9 Kg 7620 HI-POT Tester7620 Specification
8 Channels
Item AC DC IR
Voltage 100V - 5kV 100V - 6kV 100 - 1kVdc
Frequency 50 / 60Hz - -
Range 0.001 - 10mA 0.001 - 5mA 1M - 9.99GΩ
Arcing 1 - 9 1 - 9 -
Resolution 10
Accuracy ±(3% of setting+5V)
General
Flash Memory 30 Sets
Display 128*64 graphic
Voltage 115 / 230Vac ± 15% Power Supply Frequency 50 / 60Hz ± 5%
Dimension (W*H*D) 435x145x522 mm
Weight 15 Kg
www.microtest.com.tw 31
Transformer 3-in-1 Transformer Tester Tester 3 6235+7721+6905
RS232 Remote
6235 7721 6905 Basic precision up to 0.1% The fully programmable Test items include (AC Test frequency up to 1MHz continuous test Withstand, DC Withstand, Automatic Level Control Insulation Resistance)
Key Feature Optional Meter Mode function Function (ALC) Ramp time setting High accuracy and stability 21 Channel test User-friendly interface, easy to With Multi Winding Test operate Function
Standard Optional Power cord Remote Cable (25Pin/25Pin) PC Link Software User manual CD RS-232 Cable Dual Scan Box (F7721-D)
Accessory Scan Box (F7721) 24V Switch Power Supplier HV Test Cable General Transformer Tester Impulse/Surge Tester HIPOT Tester
6235 6236 6237 7721 6905
Max. Frequency Impulse Voltage Output Voltage
AC 100V - 5kV, DC 100V - 6kV, 200kHz 500kHz 1MHz 200V - 5000V IR 100V - 1000V
32 Comprehensive Test Transformer Tester 6235 Transformer Tester 7721 Impulse/Surge Tester7721 Measuring Parameter Test Function Turn Ratio, Phase, L, Q, Leakage L, Balance, ACR, Cp, D, X, Y, DCR, Pin Short Total Area
Measuring Range Area size comparison L, LK 0.1nH - 9999.99H Waveform comparison C 0.00001pF - 999.99mF Flutter Q, D 0.00001 - 99999 Coronan Z, X, R 0.00001Ω - 99.9999MΩ Transformer Tester
Y 0.01nS - 99.9999S Measuring Range θ -180° - +180° Channel 21 Channels DCR 0.01mΩ - 99.999MΩ Impulse Voltage 200 - 5000V Turn 0.01 - 99999.99 turns Pin-Short 12 pairs, between pin to pin General
General Flash Memory 200 sets Flash Memory 64 stes 320*240 dot-matrix Display Display 320*240 dot-matrix display display 90 - 125Vac or Voltage 115 / 230Vac ± 15% 190 - 250Vac Power Supply Power Supply 50 / 60Hz ± 5% Frequency 48 - 62Hz Dimension 435x190x522 mm (W*H*D) Dimension (W*H*D) 435x145x522 mm Weight 9 Kg Weight 16 Kg 6905 HIPOT6905 Tester Measuring Item Channel
AC, DC , IR 2 Channel
Measuring Range
100 - 5000Vac, 50 / 60Hz, AC Hi-Pot Insulation DC 100 - 1000V, 1M - 9.99GΩ 0.01 - 10mA
DC Hi-Pot 100 - 6000Vdc, 0.01 - 5mA Arcing 1 - 10mA
Item Range Resolution Accuracy
AC Withstand 100 - 5000Vac 10 ±(3% of setting+5V)
DC Withstand 100 - 6000Vdc 10 ±(3% of setting+5V)
Insulation Resistance 100 - 1000Vdc 10 ±(3% of setting+5V)
General
Flash Memeory 30 sets Insulation DC 100 - 1000V, 1M - 9.99GΩ
Display 128*64 graphic Arcing 1 - 10mA
Dimension Voltage 115 / 230Vac ± 15% 435x145x522 mm Power Supply (W*H*D) Frequency 50 / 60Hz ± 5% Weight 15 Kg
www.microtest.com.tw 33
Transformer 4-in-1 Transformer Tester 3Tester 6235+6210+7721+6905
RS232 Remote
Full Function Feature and the Most Efficient Test System One System with Multiple Functions, Provides a "Comprehensive Test", "Interlayer Short Circuit", "Pressure Durable Test", "DC Overlap Current Source" High and Low Pressure Test Simultaneously, Save your Time Key Feature Easy to Edit Environment, Easy to Learn To collocate with the jigs reach the highest production efficiency The maximum test frequency is up to 1MHz Maximum 5000V Test Voltage Positive/Negative Direction Electric Current Switch Function
Standard Optional Power cord Remote Cable (25Pin/25Pin) PC Link Software User manual CD RS-232 Cable Dual Scan Box (F7721-D)
Accessory Scan Box (F7721B) 24V Switch Power Supplier Customize Accessory HV Test Cable General Transformer Tester DC Bias Impulse/Surge Tester HIPOT Tester 6235 6236 6237 6210 7721 6905
Max. Frequency Output Current Impulse Voltage Output Voltage
AC 100V - 5kV 200kHz 500kHz 1MHz 0.000A - 5.000A 200V - 5000V DC 100V - 6kV IR 100V - 1000V
34 Comprehensive Test Transformer Tester 6210 DC Bias 6235 Transformer Tester Measuring Parameter Test Function Turn Ratio, Phase, L, Q, Leakage L, Balance, ACR, Interchangeable Current Function Cp, D, X, Y, DCR, Pin Short Current Graphic Scanning Analysis Measuring Range Frequency Graphic Scanning Analysis L, LK 0.1nH - 9999.99H 6235+6210+7721+6905 C 0.00001pF - 999.99mF Temperature-rising Graphic Analysis Q, D 0.00001 - 99999 Output Current Z, X, R 0.00001Ω - 99.9999MΩ 0.000A - 5.000 Y 0.01nS - 99.9999S Current Accuracy Transformer Tester θ -180° - +180° 0.000A - 1.000A 1%+5mA DCR 0.01mΩ - 99.999MΩ 1.001A - 5.000A 2% Turn 0.01 - 99999.99 turns Frequency 20Hz - 1MHz Pin-Short 12 pairs, between pin to pin General General Consumption 320W max. Flash Memory 64 sets Power Display 320*240 dot-matrix display Voltage 88 - 264Vac 90 - 125Vac or Power Supply Voltage Frequency 47 - 63Hz Power Supply 190 - 250Vac Dimension Frequency 48 ~ 62Hz 435x145x522 mm (W*H*D) Dimension (W*H*D) 435x145x522 mm Weight 9 Kg Weight 9 Kg 7721 Impulse/Surge Tester7721
Test Function Total Area、Area size comparison、Waveform comparison、Flutter、Corona Measuring Range Channel 21 Channels Impulse Voltage 200 - 5000 V General Flash Memory 200 sets Dimension (W*H*D) 435x190x522 mm Display 320*240 dot-matrix display Weoght 16 Kg Power Supply 115 / 230Vac ± 15%, 50 / 60Hz ± 5% 6905 HIPOT6905 Tester Measuring Item Channel AC, DC , IR 2 Channels Measuring Range 100 - 5000Vac , 50 / 60Hz, AC Hi-Pot Insulation DC 100 - 1000V, 1M - 9.99GΩ 0.01 - 10mA DC Hi-Pot 100 - 6000Vdc, 0.01 - 5mA Arcing 1 - 10mA Item Range Resolution Accuracy AC Withstand 100 - 5000Vac 10 ±(3% of setting+5V) DC Withstand 100 - 6000Vdc 10 ±(3% of setting+5V) Insulation Resistance 100 - 1000Vdc 10 ±(3% of setting+5V) Power Supply Voltage 115 / 230Vac ± 15%,Frequency 50 / 60Hz ± 5% Demension 435x145x522 mm Weight 15 Kg (W*H*D) General Flash Memory 30 sets Insulation DC 100 - 1000V, 1M - 9.99GΩ Display 128*64 graphic Arcing 1 - 10mA
www.microtest.com.tw 35
Cable4 Tester 4-Wire Cable Tester 8700
RS232 Remote USB Option
Precise 4-wire measurement Auto-scan and auto pin search Intermittence Open/ Short and conductance test It completes “Linear” and “Safety” tests simultaneously Key Feature The fully programmable continuous test Support statistic and print functions Support USB interface for data storag/PC connection software DC maximum voltage measurement up to 1500V / AC maximum voltage measurement up to 1000V
Standard Optional Power cord Remote Cable User manual CD D-Sub Footswitch
Accessory Test Prob Calibration Kit (KB-8685K1) Connection Cable (AK-8600F3) Meter Link Software RS-232 Cable
Advanced Function
Precision 4 wire testing Self-calibration and zero- setting
Programmable continuous test Auto-diagnosis
Pin search Function
36 4-Wire Cable Tester Cable Tester
Specification 64 / 128 / 256 Pins
Test Point High Voltage Calibration for Positive / Negative Output
Automatic Search for Terminal Point
Basic Accuracy ±5%
Test Speed 0.01 Sec
Test Mode Auto / Short Scan (selectable) Cable TesterCable
DCR Rated Output 5Vdc
AC Hipot : 50 - 1000Vac / DC Hipot : 50 - 1500Vdc
Hipot Test Resolution : 10Vdc / 10Vac
Accuracy : ±1%
DUT Requirement N/A
Panel System / Rapid / Edit / Function
Indicator Pass / Fail / HV output LED red-green indicator lights / Screen Display / Sound
Detection Mode Define upper and lower thresholds according to main and sub parameters General Power Supply 90 ~ 132Vac or 198 ~ 264Vac (selectable)
Display 320*240 dot-matrix display
Interface RS-232、Print Port、Remote Control、USB (option)
Flash Memory 56 sets
Operation Auto、Manual、continuous test、RS-232
Environment Temperature : 10 ~ 40℃ / Humidity : 20 ~ 90%
Dimension (W*H*D) 445x190x452 mm
Weight 13 Kg Parameter Item Range Item Range
Open / Short (O/S) 1kΩ - 50kΩ Capacitance (C) 10pF - 1000µF
Instant Short Circuit 1kΩ - 50kΩ Diode 0 - 7V
Endpoint Short Test With this feature Resistance Max. 10MΩ
Conductance 0.1mΩ - 50.0Ω Insulation (IR) 0.1MΩ - 1500MΩ
Leakage Current 0.01mA - 5mA
www.microtest.com.tw 37 Cable4 Tester 2-Wire Cable Tester8730
RS232 Remote
The maximum measured test points is 256 points It completes“Linear”and“Safety”tests simultaneously Optimized Man-Machine Interface, Simplified Operation Procedure Provide Single-Side Test / Insulation Test Key Feature Simple Ox-Horn Terminal Output without Switch Board Pressure Durable or Moisture Problems Number of Test File Setting up to 250 groups USB Interface (Software Update, Test results, Backup Setting) High Speed Intermittence Open/Short Function Output Electric Current Leakage Allowance of Pressure Durable Test 5mA, Intermittence 10mA The fully programmable continuous test To adopt the advanced technology of the “Intermittence Open/ Short and conductance test” Auto-scan and auto pin search
Standard Optional Power cord Remote Cable User manual CD D-Sub Footswitch
Accessory Test Prob Calibration Kit (KB-8730K1) Fixture Flat Cable 30cm (AK-8600F1)
38 2-Wire Cable Tester Cable Tester Specification Model 8730N 8730NA 8730FA
AC Hipot - 100 - 700V 100 - 1000V
DC Hipot 100 - 1000V 100 - 1000V 100 - 1500V
Leakage Current 0.01mA - 5mA
Insulation 1MΩ - 1GΩ
Test Point 128 / 256 Pins
Rated Output 5Vdc
HV Output Accuracy ±5% TesterCable
Resolution 50V
Hipot Basic Accuracy ±5%
Measuring Time 0.01 Sec
Test Mode Auto / Manual / External Trigger
Measuring Signal Low Voltage Measurement Signal
DUT Requirement Maximum Electric Capacity Allowance 1µF
Panel System / Rapid / Edit / Function Advanced Function General Voltage 115 / 230 Vac ±10% Programmable Power Supply continuous test Frequency 60 / 50 Hz Pin search Display 320*240 dot-matrix display
Interface Printer Port、RS-232 Auto-diagnosis
Flash Memory 250 sets
Operation Manual、 Auto、 Remote Control
Temperature : 15 ~ 35℃ Environment Humidity : RH ≦ 75%
Dimension (W*H*D) 435x145x406 mm
Weight 8.5 Kg Measuring Range Item Range Item Range
Open/Short 2kΩ - 50kΩ Capacitance 10pF - 1µF
Intermittence O/S 2kΩ - 50kΩ Diode 0 - 7V
O/S determinal Judge with this feature IR 1MΩ - 1000MΩ
Conductance Max. 50.0Ω Single-Side Test with this feature
Resistance Max.10MΩ AC Leakage Current Max. 5mA
www.microtest.com.tw 39 NEW Cable4 Tester 2-Wire Cable Tester8740
RS232 Remote
128 / 256 / 512 testing points Number of test file up to 500 sets Multiple DUT testing - 4 pieces(standard)/14 pieces(option) Identify the defective step of sequencial multiple DUT test Key Feature Automatically identify the normal or reverse plugin of connectors Capacitor polarity and diode leakage current test DC Hipot insulation test rapidly AC/DC Hipot leakage current test rapidly With single ended cable Open/Short test and HV Insulation/Leakage Current Test With Open/Short/Conductance/Components test Extendable testing ranges of Open/Short: 2k ~ 100kΩ Advanced technology high speed of “Intermittence Open/ Short and Conductance Test” USB (Software update, test results storage, files up/down) With Speaker/Earphone jack LCD contrast/Sound Volume (adjustable)
Standard Optional Power cord Remote Cable User manual CD D-Sub Footswitch
Accessory Test Prob Calibration Kit (KB-8730K1) Fixture Flat Cable 40cm (AK-8600F2)
40 2-Wire Cable Tester Cable Tester Specification Model 8740N 8740NA 8740FA
AC Hipot - 100 - 700V 100 - 1000V
DC Hipot 50 - 1000V 50 - 1000V 50 - 1500V
AC Leakage Current 0.01mA - 5mA
DC Leakage Current 0.1µA - 1000µA
Insulation 1MΩ - 1GΩ
HV Output Accuracy ±5%
Hipot Basic Accuracy ±5% TesterCable
Rated Output 5Vdc
Low Voltage Resistance 0.1Ω - 1MΩ
Test Point 128 / 256 / 512 128 / 256 / 512 128 / 256
Measuring Time 0.01 Sec
Test Mode Auto / Manual / External Trigger
Measuring Signal Low Voltage Measurement Signal
DUT Requirement Maximum Electric Capacity Allowance 1µF
Pass / Fail / HV output LED red-green indicator lights / Screen Display / Indicator Sound Advanced Function General Voltage 115 / 230 Vac ±10% Programmable Power Supply continuous test Frequency 60 / 50 Hz
Display 320*240 dot-matrix display Pin search
Interface Printer Port、RS-232、USB Auto-diagnosis
Flash Memory 500 sets
Operation Manual、 Auto、 Remote Control
Temperature : 15 ~ 35℃ Environment Humidity : RH ≦ 75%
Dimension (W*H*D) 435x190x406 mm (512 Pins)
Weight 14 Kg (512 Pins) Measuring Range Item Range Item Range
Open/Short 2kΩ - 100kΩ Diod 0 - 7V
Intermittence O/S 2kΩ - 100kΩ IR 1MΩ - 1GΩ
O/S determinal Judge with this feature Single-Side Test with this feature
Conductance Max. 50.0Ω AC Leakage Current 0.01mA - 5mA
Resistance Max. 1MΩ DC Leakage Current 0.1µA - 1000µA
Capacitance 10pF - 1µF
www.microtest.com.tw 41 Motor5 Tester Motor Stator Tester6910
RS232
Using the 4-wire measurement will be more accurate than others To meet the standard test projects requirement of the international companies To control and analysis the programs will reduce the human careless and misjudgment Easy to edit environment and easy to learn Key Feature It can test multiple sets of DUTs simultaneously The Impulse/Surge with waveform comparison is a non-destructive analysis When there are several DUTs are tested, it could identify the undesirable sets individually Maximum saved files will be up to 100 sets It provides the password function Speeding test could save time and improve efficiency
Standard Optional Power cord Customized Fixture User manual CD PC Link Software
Accessory HV Test Cable Foot Switch RCA adapter Temperature Test Prob RS-232 Cable Remote Cable (25F-25F)
42 Motor Stator Tester Motor Tester Specifiction DCR
Range 0.1mΩ - 100kΩ (4-wire measurement)
Low Resistance:0.1mΩ - 1Ω ±( 0.2% ± 1mΩ) Accuracy High Resistance:1Ω - 100kΩ ±0.1%
HIPOT
Voltage AC 0.1kV - 5kV / DC 0.1kV - 6kV
Leakage Current AC 0 - 10mA / DC 0 - 5mA
Arcing 0 - 9
Test Speed 0.1 - 99.9 Sec Motor Tester
Accuracy ±3%
IR
Voltage 100V - 1000V ±5%
Range 1MΩ - 9.9GΩ
Test Speed 0.1 - 99.9 Sec
Accuracy ±3%
Short Circuit
Voltage 0.2kV - 5kV ±2%
Function Total Area、Area size comparison、Flutter、Waveform comparison、Corona
Accuracy ±2% General Channel 8 channels Operation Manual、RS-232
Pass/Fail Screen Diaplay Temperature : 10 ~ 40℃ Indicator Environment Sound Humidity : 20 ~ 90%
According to the test Dimension 435x145x522 mm...... 6905 Fixture requirements (W*H*D) 435x190x522 mm...... 6910
90 ~ 132Vac or 198 ~ 264Vac 12.5 Kg...... 6905 Power Supply Weight 60 / 50 Hz 11 Kg...... 6910
128*64 dot-matrix...... 6905 Interface RS-232 Display 320*240 dot-matrix...... 6910 Flash Memory 100 sets
Range Item Range Item Range
DCR 0.1mΩ - 100kΩ Leakage Current 0.1mA - 10.0mA
IR 1MΩ - 9.9GΩ Impulse Voltage 200V - 5000V
www.microtest.com.tw 43 Motor5 Tester Motor Stator Tester6913/6917
RS232
Using the 4-wire measurement will be more accurate than others To meet the standard test projects requirement of the international companies To control and analysis the programs will reduce the human careless and misjudgment
Key Feature Easy to edit environment and easy to learn It can test multiple sets of DUTs simultaneously When there are several DUTs are tested, it could identify the undesirable sets individually The Impulse/Surge with waveform comparison is a non-destructive analysis Maximum saved files will be up to 100 sets It provides the password function Speeding test could save time and improve efficiency
Standard Optional Power cord Customized Fixture User manual CD PC Link Software
Accessory HV Test Cable Foot Switch RCA adapter Temperature Test Prob RS-232 Cable Remote Cable (25F-25F)
44 Motor Stator Tester Motor Tester
Specifiction DCR
Range 0.1mΩ - 100kΩ (4-wire measurement)
Low Resistance:0.1mΩ - 1Ω ±( 0.2% ± 1mΩ) Accuracy High Resistance:1Ω - 100kΩ ±0.1%
HIPOT
Voltage AC 0.1kV - 5kV / DC 0.1kV - 6kV
Leakage Current AC 0 - 10mA / DC 0 - 5mA
Arcing 0 - 9
Test Speed 0.1 - 99.9 Sec Motor Tester
Accuracy ±3%
IR
Voltage 100V - 1000V ±5%
Range 1MΩ - 9.9GΩ
Test Speed 0.1 - 99.9 Sec
Accuracy ±3%
Short Circuit
Voltage 0.2kV - 5kV ±2%
Function Total Area、Area size comparison、Flutter、Waveform comparison、Corona
Accuracy ±2% General 13 channels...... 6913 Operation Manual、RS-232 Channel 17 channels...... 6917 Temperature : 10 ~ 40℃ Pass/Fail Screen Diaplay Environment Indicator Humidity : 20 ~ 90% Sound Dimension 435x145x522 mm...... 6905 According to the test Fixture (W*H*D) 435x190x522 mm...... 6913/6917 requirements 12.5 Kg...... 6905 Weight Power 90 ~ 132Vac or 198 ~ 264Vac 15 Kg...... 6913/6917 Supply 60 / 50 Hz 128*64 dot-matrix...... 6905 Display Interface RS-232 320*240 dot-matrix....6913/6917
Flash 100 sets Memory Range Item Range Item Range
DCR 0.1mΩ - 100kΩ Leakage Current 0.1mA - 10.0mA
IR 1MΩ - 9.9GΩ Impulse Voltage 200V - 5000V
www.microtest.com.tw 45 Motor5 Tester Motor Armature Tester 6920
RS232
Pneumatic Synchronization Measurement Fixtures, Avoid Scratching the DUT to be Measured To control and analysis the programs will reduce the human careless and misjudgment Easy to edit environment and easy to learn Key Feature Using the DCR 4-wire Measurement Chinese/English screen could be switched arbitrarily Optional for PC connection software to progress CPK analysis
Standard Optional Power cord Customized Fixture User manual CD PC Link Software
Accessory HV Test Cable Foot Switch RCA adapter Temperature Test Prob RS-232 Cable Banana Plug Cable
46 Motor Stator Tester Motor Tester Specifiction DCR
Range 0.1mΩ - 100kΩ (4-wire measurement)
Low Resistance:0.1mΩ - 1Ω ±( 0.2% ± 1mΩ) Accuracy High Resistance:1Ω - 100kΩ ±0.1%
HIPOT
Voltage AC 0.1kV - 3kV / DC 0.1kV - 3kV
Leakage Current AC 0 - 10mA / DC 0 - 5mA
Arcing 0 - 9
Test Speed 0.1 - 99.9 Sec Motor Tester Accuracy ±3%
IR
Voltage 100V - 1000V ±5%
Range 1MΩ - 9.9GΩ
Test Speed 0.1 - 99.9 Sec
Accuracy ±3%
Short Circuit
Voltage 0.2kV - 3kV ±2%
Function Total Area、Area size comparison、Flutter、Waveform comparison、Corona
Accuracy ±2% General Depends on the number of slots Operation Manual、RS-232 Channel with the products (fixtures) Temperature : 10 ~ 40℃ Environment Pass/Fail Screen Diaplay Humidity : 20 ~ 90% Indicator Sound Dimension 435x145x522 mm...... 6905/6908 According to the test (W*H*D) 435x190x522 mm...... 6920 Fixture requirements 12.5 Kg...... 6905 Power 90 ~ 132Vac or 198 ~ 264Vac Weight 7 Kg...... 6908 Supply 60 / 50 Hz 11 Kg...... 6920
128*64 dot-matrix...... 6905 Interface RS-232 Display 320*240 dot-matrix...... 6920 Flash 100 sets Memory Range Item Range Item Range
DCR 0.1mΩ - 100kΩ Leakage Current 0.1mA - 10.0mA
IR 1MΩ - 9.9GΩ Impulse Voltage 200V - 3000V
www.microtest.com.tw 47 NEW Automatic Testing Equipment Single-Phase Power Meter 6 7110/7120
RS232 GPIB Option
AC / DC Dual amp / watt-hour meter Wide range 0.001W ~ 16KW Connection software attached
Key Feature Standby Power D.P.I. of 0.001W With crest factor ratio display Up to the 50 levels harmonic wave analysis capability 1000 sets of measurement data storage space
Standard Optional Power cord GPIB Cable User manual CD PC Link Software Accessory RS-232 Cable TL218 Alligator Clips F71201 Test Box TL208 2mm Test Prob
Measuring Range
Vrms 0.1V - 600V PF 0.000 - ±1.000
Vdc 0.1V - 600V Deg -180° - +180°
Irms 0.1mA - 20A THD 0.01% - 999.99%
Idc 0.1mA - 20A Hz 15Hz - 100kHz
W 0.01W - 16kW
48 ATE Automatic Testing Equipment
Harmonics Analysis Base Achieve stable fundamental frequency by voltage or current (non-inverter) Frequency Range 45Hz - 440Hz FFT Data Length 1024 FFT Data Format 32 bits 1-50 THD, 1-50 level voltage and current V [n], A [n] 1-50 level voltage and current distortion percentage V [n%], A [n%] 1-50 level watts W [n] Measurement Item 1-50 level watts distortion percentage Watt W [n%] 1-50 level voltage and current angle DEG [n] Vrms,Irms,Watt, PF Frequency Model 7110 7120 Automatic TestingEquipment Measuring Mode Achieve stable fundamental frequency by voltage or current (non-inverter) Frequency Range DC 15Hz - 10kHz DC 15Hz - 100kHz Data Length Dual 4096x16 RAM for voltage & current ADC Resolution 16 bits Sampling Rate AC 50 / 60Hz basic sampling rate 100KSPS/120KSPS Arithmetic Precision Watt / VRMS / IRMS / MEAN / PF / Deg / Line filter 32bits Frequency Filter 500Hz cut off,digital chip filter based on 25MHz 500Hz - 3db digital filter based on Butterworth Signal Filter 50Hz - 0.03% reading,60Hz - 0.05% reading Frequency Acquisition Voltage / current 100MHz baseband digital dynamic meter chip Subject to the current, analog / digital hybrid detecting (error less than 5 Phase Lead Detection degrees) General Model 7110 7120
Power Supply Voltage : 100 ~ 240Vac,Frequency : 50 / 60Hz Display Seven-segment display Interface RS-232 RS-232、GPIB Flash Memory 6 sets Operation Temperature:23℃ ±5℃,Humidity:20~80% Dimension (W*H*D) 227x101x300 mm Weight 1.85 Kg Measuring Bandwidth DC 15Hz - 10kHz DC 15Hz - 100kHz Harmonic Function Optional Optional 7110-10k-HARM 7120-100k-HARM Model 7110-10k 7120-100k Fixture F71201 TEST BOX Range Current (fixed / auto) 0.01A、0.03A、0.1A、0.3A、1A、3A、10A、20A
Voltage (fixed / auto) 10V、30V、100V、300V、600V
www.microtest.com.tw 49 RMS/MEAN Mode Voltage & Current Accuracy(23℃±5℃)
15 Hz ≦ f < 45 Hz ±(0.1% of reading + 0.4% of range)
45 Hz ≦ f ≦ 66 Hz ±(0.1% of reading + 0.1 % of range)
66 Hz < f ≦ 1 kHz ±(0.1% of reading + 0.2 % of range)
1 kHz < f ≦ 10 kHz ±(0.07*f % of reading + 0.3% of range)
10 kHz < f ≦ 100 kHz ±(0.5% of reading + 0.5% of range) ±[{0.04×(f–10)}% of reading]
F unit is 1kHz When the L-FILTER sets as ON: 45Hz-66Hz frequency range allowable error Add 0.5% of reading
When the AC is measured, if the fundamental frequency exceeds 200Hz, the F-Filter is required to be turned off in order to measure the most accurate value **When the frequency range is more than 10kHz, the 7120 starts to support DC Mode Voltage & Current Accuracy ( 23℃±5℃ )
±0.2% reading ± 0.2% ±(0.2% of reading + 0.2% of range) 10V-600V 0.01A-20A of range ±offset
To add up the OFFSET errors of various files during measuring the DC current
Power (W) Accuracy ( 23℃±5℃ )
AC power ranges (Auto or Manual) (40 ranges) range up to 16kW Maximum Power (W) value is determined by the highest range of voltage profile
DC ±0.2% reading ± 0.5% of range 15 Hz ≦ f < 45 Hz ±(0.3% of reading + 0.2 % of range) 45 Hz ≦ f ≦ 66 Hz ±(0.1% of reading + 0.1 % of range) 66 Hz < f ≦ 1 kHz ±(0.2% of reading + 0.2 % of range) 1 kHz < f ≦ 10 kHz ±(0.4% of reading + 0.3 % of range)± [{0.06×(f)}% of reading] 10 kHz < f ≦ 100 kHz ±(0.5 % of reading + 0.5 % of range)±[{0.09×(f–10)}% of reading]
Incidental allowable error conditions
Frequencies between 45Hz-66Hz: Add 0.3% of reading Signal filter error (AC) Frequency out of 45Hz-66Hz: Add 1% of reading beyond
CF9 error (DC) Add range tolerance * 3
Accuracy effect of the phase error of the power
When the power factor PF is 0, the error range of Watt is Situation 1:for 45 Hz < f,Add±1.0% of VA Situation 2:for 45 Hz > f or f > 66 Hz Add ±{(3.5 + 0.5×f )% of VA} for up to 100 kHz as reference data The unit for frequency f is kHz. When the power factor is 0 < PF ≦ error range When 0 < PF ≦ 1 (θ:phase angle of the voltage and current) for 45 Hz ≦ f ≦ 66 Hz. Add ± power reading *{tan(θ)*(0.5)}% for f < 45 Hz, f > 66 Hz. Add ± power reading *{ tanθ* (0.5×f+0.2) }%
Error within 12 months Add ±(0.5% of reading)
50 ATE Automatic Testing Equipment
Automatic Testing LIPS Testing System Equipment6 PT-9000
Scalable with special LED backlight Measuring fixture Scalability up to 16 sets of Output LED backlighting products
Key Feature To achieve the goal of rapid detection by
using the standard GPIB interface with the Automatic TestingEquipment IEEE-488.2 Easy to edit environment, easy to learn Scalability the INVERTER and the LIPS models Scalability of 1 to 64 lamps of the INVERTER products and the LIPS models The INVERTER provides three different kinds of dimming modes, including voltage, PWM, and SMBUS Modular design, easy to maintain It supports Barcode Reader It provides statistical reporting capabilities
Motor drive、UPS、Chargers、Power supplies Other power products Application
Application Integration
Standard Power cord 8255 cable User Manual CD Fixture flat cable
Accessory SCSI cable PC Link Software
Optional Inverter test fixture LED driver test fixture GPIB cable
www.microtest.com.tw 51 Function POWER INVERTER
Inrush Current Output Power
Turn On Delay Time Ouput Current
Rise Time (mS) Ouput Voltage
Over Shoot (V) or (%) Ouput Frequency
Hold up Time (mS) Burst Mode Frequency
Fall Time Striking Time
Dynamic Load (V) Ouput Voltage Balance
Short Protection Ouput Current Balance
Over Current Protection Open Lamp Protection
Recovering (V) DUTY
Over Voltage Protection (V) Efficiency
Regulation (V) Lin(A)
Line Regulation PF
Ripple & Noise(mVp-p) Linpk+(A)
Combine Test (V) Linpk-A)
Pin (W) Vin (V) Specification Fixture Inverter / LED Backlight Driver Test Fixtures
Measuring output array 16 - 32 sets Lamp
Measuring input array 1 set
DC Power Supply 35VDC / 10A (Expansible)
AC Power Supply 300V / 1kVA
Bar Code Settable
Fixture Compensation Software Compensation
52 ATE Automatic Testing Equipment
Specification Control Power Supply
Regulated Light Power Supply 10VDC / 200mA (Max.)
Spare Power Supply -1, -2
PWM dimming -1 60Hz - 1kHz / Step 1Hz , Duty 1 - 99% / Step 1%
PWM dimming -2 60Hz - 100kHz / Step 1Hz , Duty 1 - 99% / Step 1%
SMBus Dimming Control DALLAS of DS1803 , Data (Series) , Clock (TTL)
Output Current 1mA - 10mA resolution 10µA
Output Voltage 100Vrms - 3000Vrms resolution 1Vrms Automatic TestingEquipment Output Frequency 10kHz - 100kHz resolution 10Hz
Burst Mode Frequency 100Hz - 2kHz resolution 1Hz
Burst Mode Duty 1% - 99%
Lighting Protection Time 0 - 5 Sec resolution 0.01Sec
1. The Max. difference value of subtracting from each other Lamp Current Balance 2. The difference value of subtracting from the Max. to the Min. 3. The Max. difference value with the standard value
High / Low Voltage Protection Starting voltage point of the test protection
Short Circuit Protection Confirm whether action or not
Efficiency 0 - 100%
Total Input Voltage 600V (Max.) DC and 10Hz to 100kHz
Total Input Electric Current 20A (Max.) DC and 10Hz to 100kHz
Positive / Negative Peak Value ±60A (Max.) 10Hz - 100kHz of Input Electric Current
Adapter Efficiency 0 - 100%
P.F. 0 - 1
Inrush Current 50A Max.
Timing measurement 0 - 2 Sec resolution 0.01mS
Dynamic Load THIGH & TLOW 50µ Sec to 9.999 Sec (DC LOAD)
Load Regulation DC Load Model 3310:60V / 30A (Max.) Line Regulation
3312:30V / 10A (Max.) Combine Test
www.microtest.com.tw 53 Automatic Power Switch / LED Power Testing Testing Equipment6 System PT-9200/PT-9300
Suitable functional testing for LED power supply and Switching Power products Easy to edit environment, easy to learn Suitable for continuous or single project test Key Feature Suitable for AC-DC/DC-DC related power products Suitable for multiple sets testingThe fixtures can be used for double-cut to promote the efficiency Shop-Floor function and data integration Debug mode to get the testing certification easily Modular design, easy to maintain It supports Barcode Reader Statistical reporting capabilities
Standard SCSI cable 8255 cable
Accessory Fixture flat cable Power Cord User manual CD PC Link Software
Optional AC to DC charger test fixture DC to DC charger test fixture GPIB cable
RS232 Remote
54 ATE Automatic Testing Equipment
Specification Fixture AC to DC / DC to DC adapter / charger fixture / LED Power fixtures
Number of output array Up to 8 sets DC output
Number of input array 1 set
DC Power Supply Purchase by specification
AC Power Supply Purchase by specification
PWM dimming-1 60Hz - 1kHz / Step 1Hz , Duty 1 - 99% / Step 1%
PWM dimming-2 60Hz - 100kHz / Step 1Hz , Duty 1 - 99% / Step 1%
SMBus Dimming Control DS1803 of DALLAS , Data (Series) , Clock (TTL)
Over Voltage Protectoion Action confirm
Short Protectoion Action confirm Automatic TestingEquipment Adapter Efficiency 0 - 100%
P.F. 0 - 1
Inrush Current 50A Max.
Timing measurement 0 - 2 Sec resolution 0.01mS
Dynamic Load THIGH & TLOW 50µ - 9.999 Sec (DC LOAD)
Load Regulation
Line Regulation DC Load Model
Combine Test
Bar Code Settable
Fixture Compensation Software Compensation Function Measuring Item ( PT-9200 / PT-9300 )
Inrush Current Regulation (V)
Turn On Delay Time Line Regulation
Rise Time (mS) Ripple & Noise(mVp-p)
Over Shoot (V) or (%) Efficiency
Hold up Time (mS) Combine Test (V)
Fall Time Pin (W)
Dynamic Load (V) PF
Short Protection Vin (V)
Over Current Protection Iin(A)
Recovering (V) Iinpk+(A)
Over Voltage Protection (V) Iinpk-(A)
www.microtest.com.tw 55 Automatic Testing Universal Function Tester Equipment6 PT-960F
Computerized control and analysis, simple edit environment, easy to learn Editing environment of table type program Fully programmable continuous test Key Feature Modular design can be easily upgraded Standard IEEE-488.2 GPIB interface It provides 17" LCD screen display It provides a variety of expansion cards to meet the various requirements It provides a variety of interfaces to be utilized in different applications
Standard Power cord PT960F software
Accessory User manual CD
RS232 Remote Optional Customized
56 ATE Automatic Testing Equipment Specification Statistical Analysis and Report Automatic Simulation Test Advanced Features Harmful Analysis Continuous Testing Memory Management Basic Accuracy Depends on the Measurement Unit Measure Electric Circuit Depends on the Measurement Unit Power Analysis Device AC Power Supply DC Electric Current Load Optional Measurement Precision ElectricityMeter Unit Oscilloscope (OSC) Spectrum Analysis Device
Network Analysis Device Automatic TestingEquipment P Ⅲ / 1G Computing Platform Microsoft Win98 / WinXp (no update for Win98) Germany Schuh PT-960F System Display / Sound Device Pass / Fail Screen Display / Computer Sound Measurethe Points Made-to-Order (possible collocate to the fixtures) Keyboard Control / Editing Unit Foot Switch RS-232 Interface GPIB Printer Port Power Supply 110 / 230 Vac ±10% (auto selection) Expansion Control Card 50 / 60Hz (Optional) Number of the Output Group:16 Relay Categories:SPDT Relay Card Output Types:N.O. Contact Ratio:125Vac / 1A or 30Vdc / 2A Number of the Output Group:8 Relay Categories:SPDT Power Relay Card Output Types:N.O. / N.C. Contact Ratio:250Vac / 5A or 30Vdc / 5A 0 ~ 2Vpp Multiplexer Card 8*24 Relay Number of the Output Group:3 Output Voltage:2 ~ 20Vdc, Fixed Voltage Power Card Current Limit:1.5A Contact Ratio:125Vac / 1A or 30Vdc / 2A Accessory Foot Switch、Keyboard、Power Cord、User Manual CD Temperature : 15 ~ 35℃ Environment Humidity : RH ≦ 75% The size and weight of customization will depend on the equipment and requirements
www.microtest.com.tw 57 PCB Testing High Precision / Low Impedance Equipment 7 4 -wire PCB/FPCB Tester 9330/9330S
RS232 Remote
The main feature of MICROTEST 9930 is the resistance of the PC board copper wiring is enable to do the general examination and precision measurement simultaneously. Meanwhile, the minimum resistance can be measured to 1mΩ. The mechanical structure with double cylinder press to increase the stability of the testing. Key Feature The existing applied industry is the high-tech 3C products. For instance, the smart phones and the wearable electronics need fine quality testing of PCB or FPCB, and the high security requirements of PCB of the central instrument control panels and the various sensible parts of the cars requires a lot of high precise testing equipment.
58 PCB Testing Equipment Specification Model 9330 9330S
2048 Pins 4096 Pins Test Point (Max. 4096 Pins) (Max. 8192 Pins)
4-Wire Continuity test 1mΩ - 50Ω, ±1%±2mΩ
1Ω - 100Ω, ±5% 2-Wire Continuity test 100Ω - 100kΩ, ±2% 100KΩ - 1MΩ, ±5%
1MΩ - 20MΩ, ±1MΩ Insulation Test 20MΩ - 50MΩ, ±10% 50MΩ - 100MΩ, ±20%
Continuity Test Current 0.15mA - 150mA
Insulation Test Low Voltage 100mV - 10VDC PCB TestingEquipment
Insulation Test Voltage 50V - 300V
Continuity Test Time 800 Points / Sec. Approx.
Insulation Test Time 4,000 Dummy Points / Sec.
1. Auto Learn Netlist Input Method 2. File Download
OS Requirement Windows XP Dual Core 2.7G above
Storage Devices 500GB HDD, 3.5”FDD
Display 19" LCD Monitor
Printer Epson M188B Comparable
Power Supply AC220V±10% / 5A 1100W
Air Supply 5 - 8Kg / cm²
Test Area Size (W*D) 500x450 mm 900x600 mm
Cylinder Distance 250 mm
Pillar Ø25 mm Ø50 mm
Dimension (D*W*H) 830x780x1350 mm 1200x1000x2000 mm
Weight 300 Kg 750 Kg
Temperature 10 ~ 40℃ Environment Humidity Less than 50% relative
www.microtest.com.tw 59 PCB Testing Compact HDIPCB FPCB Tester Equipment7 / 9310/9310S
RS232 Remote
With Chinese/English operating system Short test : Binary fast test function With self-testing function 4-wire test / 2-wire test in one testing Provide auto scan and pin search Hight voltage open test : Max. DC300V
Key Feature Open test : Impedance of nearby nets Stable double cylinders press system Test point : Max. 8192 points Statistics of testing results
60 PCB Testing Equipment Specification Model 9310 9310S
4096 Points 8192 Points Test Points (Max. 8192 Pins) (Max. 24576 Pins)
2-Wire Continuity Test 10Ω - 10kΩ, ±10%
Insulation Test 1MΩ - 20MΩ, ±10%
Insulation Test Low Voltage 100mV - 10VDC 5V / 10V / 15V
Insulation Test Voltage 50V - 250V
Insulation Test Time 4,000 Dummy Points / Sec PCB TestingEquipment 1. Auto Learn Netlist Input Methods 2. File Download
OS Requirement Windows XP Dual Core 2.7G above
Storage Devices 500GB HDD, 3.5" FDD
Display 19" LCD Monitor
Printer Epson M188B Comparable
Power Supply AC220V±10% / 5A 1100W
Air Supply 5 - 8Kg / cm²
Test Area Size (W*D) 500x450 mm 900x600 mm
Cylinder Distance 250mm
Pillar Ø 25mm
Dimension (D*W*H) 830x780x1350 mm 1200x1000x2000 mm
Weight 300 Kg 750 Kg
Temperature 10 ~ 40℃ Environment Humidity Less than 50% Relative
www.microtest.com.tw 61 Accessory 8& Fixture Accessory & Fixture
LCR Meter / Impedance Analyzer Accessory
BNC Kelvin Clips BNC Kelvin Clips DIP Fixture Box (BNC Box)
F423501 F423502 F423504
6370 / 6371 / 6372 6370 / 6371 / 6372 6370 / 6371 / 6372 6373 / 6374 / 6375 6373 / 6374 / 6375 6373 / 6374 / 6375 / 6376 High Frequency High Frequency BNC Kelvin Clips High Frequency BNC Kelvin Clips BNC Kelvin Clips (BNC Box) (BNC Box and SMD weezer) F423901 F423902 F423903
6376 / 6377 / 6378 / 6379 6376 / 6377 / 6378 / 6379 LCR Meter / Impedance Analyzer
High Frequency BNC Kelvin DC Bias Box SMD Fixture Box DIP Fixture Box Clips (SMD Tweezer) (±200V/2MHz)
F423904 F423905 F423503 F420001
LCR Meter / Impedance Analyzer LCR Meter / Impedance Analyzer LCR Meter / Impedance Analyzer LCR Meter / Impedance Analyzer
62 Fixture Accessory
LCR Meter / Impedance Analyzer Accessory
High Frequency DIP Fixture Box Dielectric Permittivity Fixture Permeability Coefficient Fixture
FX-0000C6 FX-0000C7 FX-0000C8
6376 / 6377 / 6378 / 6379 / 6330 6630 6630
Material Testing Fixture DC Bias Scan Box F6210
FX-0000C9 Accessory & Fixture
6376 / 6377 / 6378 / 6379 / 6330 6210 / 6220 / 6240
Safety Testing Instrument Scanning Box and Fixture
HV Scan Box F7620 Dual HV Scan Box HV Test Cable
Comprehensive Transformer Testing System Fixture
Dual Scan Box F7721-D Scan Box F7721
www.microtest.com.tw 63 Transformer Tester Scanning Box and Fixture *Fixture Head is customized
Manual Transformer Scan Box Auto Transformer Scan Box Netcom Transformer Scan Box
F5220-M F5220 F5420
2.54 - 2.54 mm 2.54 - 2.54 mm 7.5 / 5 - 5 mm RJ45 (Row Spacing) (Row Spacing)
F522001 F522007 F522008 F522009
Cable / Harness Testing Instrument Accessory *Calibration Kit is optional
Universal Fixture Board 2-in-1 64 Pin Din-to-Horn Converter 64 Pin Din-to-Horn Converter
FB-8600M1 CT-8685-J1 AV-8600DH1
Fixture Connection Cable Fixture Connection Cable Fixture Flat Cable (4-Wire Cable Tester) AK-8600F3 AK-8600F2 AK-8600F1
64 Fixture Accessory
Cable / Harness Testing Instrument Accessory
RS-232 to USB Cable Handler Box HDMI Testing Fixture
Motor Testing Instrument Fixture *Motor Testing Fixture is customized
Motor Stator Testing Fixture Motor Rotor Testing Fixture Dual Motor Stator Testing Fixture Accessory & Fixture
Power Meter Accessory
F71201 Test Box TL208 2mm Test Prob TL218 Alligator Clips
www.microtest.com.tw 65