18x16 SA UP 9 18x16 RA UP 14x10 RA 18x16 SA 10"Ø EA UP

8 8 18x12 RA 18x12 RA 3 EF HD 8"Ø UH FIREARMS SR-2 HD 7 DRUG HD 1 EF SR-2 140 FH STOR. 10"Ø 10"Ø 006 S T.R. 005 8"Ø JAN. 140 10"Ø 9 R-7 18x16 SA D-6 1 012 009 007 18x10 SA 18x10 SA 200 EVIDENCE LAB HD HD HD HD HD HD HD S RT-5 003 8"Ø

R-4 R-4 8"Ø R-4 H G F D D-7 D-7 175 175 D-7 UP STOR 165 D-7 COPYRIGHT All rights reserved. Reproduction or use in any form 008 R-3 or by any means -- graphic, electronic, mechanical, etc. -- without 125 written permission of LOMBARD CONRAD ARCHITECTS, P.A. is unlawful and subject to criminal prosecution. 8"Ø EVIDENCE STOR. STOR D-7 8"Ø EXIST 004 D-7 STAMP: 2 175 EVIDENCE 380 106 225 BOOKING S UH D-7 001 EXIST D-7 TECH 2 2 175 175 D-7 385 002 125

EXIST 2 385 MECH. PLAN D-7 DISPATCH A 166 EG-1 200 R-4 10"Ø D-7 157 D-7 SCALE: 1/8" = 1'-0" D-8 NORTH HD 110 250 245 245 PLAN NOTES: HD SHOWER EXIST HD 2 8"Ø 8"Ø 385 165 HD HD 1 INSTALL BACKDRAFT DAMPER IN DUCTWORK AS SHOWN. 8"Ø SA MAT 16x12 SA CHUBBUCK 3 EG-1 HD HD 8"Ø 10"Ø RA 8"Ø 8"Ø 110 158B 2 EXISTING DIFFUSER TO REMAIN. BALANCE AIRFLOW TO POLICE STATION HD 10x10 SA 22x12 SA D-7 CFM SHOWN. HD 240 HD HD HD D-8 EF D-7 MULTIPURPOSE HD D-7 10x12 SA 3 CONNECT NEW SUPPLY AIR DUCT TO EXISTING SUPPLY AIR 10"Ø 10"Ø 250 2 245 H F

3 8"Ø 1 EXIST 105 8x8 EA 255 RT-1 DUCT. PROVIDE AND INSTALL DUCT TRANSITION AS REQUIRED. 2 385 22x12 RA S HD 8"Ø R-5 4 INSTALL NEW CONDENSING UNIT ON ON REDWOOD RAILS HD 8"Ø S EF 155 OFFICE WRAPPED IN ROOFING MATERIAL AND RECONNECT TO EXISTING HD EG-2 8"Ø 3 REFR. PIPING AND CONTROLS. D-3 D-3 F-2 6"Ø D-1 R-3 156 225 1 10"Ø 160 170 50 SR-1 HD

18x12 RA F 12x10 EA 20x10 SA F 5 INSTALL REMOTE CONDENSING UNIT ON ROOF AND DROP REFR. TOILET D-7 D-8 75 A 6 2 3 HD R-5 6 1 16x12 RA F 200 8"Ø SA PIPING DOWN THRU ROOF AND CONNECT TO NEW FAN COIL UNIT

HD 250

16x12 SA D-1 163 14x12 GYM 6"Ø R-1 8"Ø 6 3 BELOW. SEE DETAIL ON SHEET M2.0

HD 50 HD 16x12 RA 6"Ø 158A 16x12 RA D-5 F-3 S R-5 (ON ROOF) 125 A A 6 INSTALL NEW AND RECONNECT TO EXISTING PLENUM, CITY OF S F-1 HD S FC REFR. PIPING, FLUES, SUPPLY AND RETURN AIR DUCTWORK. 8"Ø RT 5 11

16x12 SA CHUBBUCK 10"Ø 1 1A ELEC. BALANCE AIR FLOW TO CFM SHOWN ON PLANS AND SCHEDULES. M TLT 20x10 SA LOCKER ROOM (ON ROOF) W TLT EG-3 FC 153 H F 12x10 SA 12x10 EA (COOLING) 103 159 HD 102 235 1 T 7 RE-INSTALL EXISTING REFR. PIPING AND COVER ON ROOF AFTER STOR 5 EF 16x12 SA 16x12 SA NEW ROOFING HAS BEEN INSTALLED. COMM. FC 8 104 D-8 FC 20x10 EA 20x10 SA (ON ROOF) 2A 3 250 154 2 8 RISE 10x3 EA DUCT UP IN ABOVE TO FLAT ROOF CAP RT (ON ROOF) MEZZANINE LEVEL MECH. PLAN 2 ABOVE. 12x10 RA R-5 10 7 A ERV (2) D-5 SCALE: 1/8" = 1'-0" L 1 10x8 RA 100 NORTH S 9 PROVIDE TRANSITION FROM FUME HOOD EXHAUST CONNECTION 101 D-3 (ON ROOF) 16x16 RA 6"Ø 10x10 EA L 10x10 SA TO 10"Ø EXHAUST DUCT AS SHOWN. S 200 HD B VEST. EG-2 TOILET 14x12 SA

100 300 8"Ø HD SR-2 SR-2 162 16x16 SA HD HD HD R-3 HD D-1 HD 225 225 INTERVIEW S SWAT/SRT

75 L

HD 10"Ø 8"Ø 12x10 SA 8"Ø CONSULTANT: S 107 8"Ø CAFE/ BREAKROOM 8"Ø 152 R-6 10"Ø 8"Ø 8"Ø

L EG-1 D-3 HD S 110 146 160 D-9 CONTRACTOR OPTION: HD 10"Ø HD D-7 240 8"Ø 8x8 EA 255 10x8 RA D-5 9 A CONTRACTOR TO VERIFY EXISTING CONDITION OF 8"Ø COPY/FILE R-1 12x12 SA 4 CU SHOWER D-2 D-2 175 REFRIGERANT PIPING. IF PIPING IS FOUND TO BE IN GOOD 108 6"Ø 3 140 140 8"Ø L 161 6"Ø CONDITION WITH NO LEAKS, CONTRACTOR CAN RE-USE S CU 8"Ø W TLT M TLT EXISTING PIPING INSTEAD OF INSTALLING NEW PIPING. IF L 6"Ø 2 4 INTERVIEW 149 148 R-3 ARMORY EXISTING PIPING IS RE-USED, CONTRACTOR MUST CLEAN AND RECEPTION PURGE LINES USING RX-11 CLEANING KIT BEFORE NEW R410A D-8 109 EG-1 150 EF R-5 6"Ø 12x10 RA D-9 8"Ø SA D-8 110 400 110 HD D-7 REFRIGERANT IS INSTALLED AND NEW CONDENSING UNITS R-1 240 6

8"Ø SA 150 400 16x10 RA 6"Ø AND COILS CONNECTED. EXISTING LINES MUST HOLD HALL D-1 PRESSURE AND DEMONSTRATE INTEGRITY THROUGH-OUT 75 CU 10"Ø 112 8 SYSTEM. 1 MECH.

10"Ø D-8

10"Ø 4 S 10x8 SA RAMP DOWN HD 8"Ø EF 6"Ø SA 295 EF 144B 20x12 RA 6"Ø 8x8 SA 5 D-5 HD HD 4 MECH. STOR. HD HD HD HD 10"Ø T.R. 90 RT 144 R-3 18x12 SA 4 D-9 D-1 142 HD 143 240 50 12x10 RA 18x10 RA (ON ROOF) 6"Ø 8"Ø 7 8"Ø R-3 8"Ø ROOF HATCH HD 10"Ø 6"Ø

CONF. 6"Ø RT RT D-7 8"Ø 117 3 S R-3 5 175 HD R-3 18x10 SA (ON ROOF) D-8 EXIST DN (ON ROOF) 2 R-3 R-3 8"Ø 300 RECORDS D-7 DESCRIPTION 75 CAPTAIN IT OFFICE HD 6"Ø SA 8"Ø 175 COPY/FILE 10"Ø SA 5

114 115 116 10x8 RA STOR. HD HD 134 R-2

12x10 SA 12x10 SA HD HALL LOBBY D-4 113 18x10 SA D-7 18x12 SA HD HD 8"Ø HD 10"Ø EA DN. 8"Ø 125 8"Ø 175 145A 18x16 SA 135 D-5 8"Ø D-6 RAMP D-5 D-5 10x10 SA UP C 160 8 160 160 200 18x16 RA 119 EF INTOX 1 8"Ø 3 8 PTRL. LT. 18x16 RA D-5 T.R. D-5 CHD 137 R-4 8"Ø 8"Ø (ON ROOF) 10x8 RA 8"Ø 175 18x16 RA DN. 175 130 STOR. DATE HD 127 HD HD 8"Ø RT 18x16 SA DN. GENERAL NOTES: D-7 R-5 R-5 UP 225 12x10 SA 12x10 SA 18x10 SA 9 136 D-4 10"Ø HD 10x8 RT D-7 R-2 125 A- THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS OFFICE T.R. 12x10 (ON ROOF) EXIST. RAMP 7 CONF. 175 AND CONNECTIONS ON THE JOB SITE. ALL WORK SHALL BE 126 RT MRK 121 R-3 129 R-3 RAMP EXECUTED FROM MEASUREMENTS TAKEN AT THE SITE. (ON ROOF) 20x12 RA 6

8"Ø D-8 8"Ø

CONF. CHD INTERVIEW 141A 10"Ø SA S 375 VEST. S (ON ROOF) 125 138 B- THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE TO JOB N0.: 18040.01 18x12 RA 8"Ø 8"Ø 128 S 8"Ø SA INSURE PROPER CODE CLEARANCES FOR ELECTRICAL AND DATE: 03/26/21 8"Ø 8"Ø RT S 10"Ø 8"Ø D-4 MECHANICAL ACCESS WHEN INSTALLING ANY EQUIPMENT DRAWN BY: SR HD R-4 HD 18x10 RA 8 D-8 125 CHECKED BY: R-2 SUPPLIED BY THE MECHANICAL CONTRACTOR. DCS

12x8 RA R-3 (ON ROOF) 250 10x10 SA D-7 PATROL D-7 12x10 20x12 SA

132 C- 200 200 8"Ø INTERVIEW IT IS CRITICAL THAT THIS CONTRACTOR COORDINATE CHIEF 10"Ø RA 131 D-7 R-4 DN CHD PHASE: PERMIT DWGS. R-3 18x10 SA EQUIPMENT LOCATIONS WITH PIPING, DUCTWORK, ELECTRICAL PTRL. SGT. 8"Ø RA 18x10 RA 8"Ø 8"Ø 205 8"Ø R-4 139 118 HD HD HD 14x10 RA CONDUIT AND STRUCTURE TO INSURE CODE DET. LT. R-4 16x10 SA 20x12 SA COMPLIANCE. OFFICE HD HD 8"Ø 120 HD HD D-4 MECHANICAL 124 D- CEILING DIFFUSERS ARE SHOWN IN APPROXIMATE LOCATIONS. 8"Ø R-2 135 HD 8"Ø 8"Ø HD HD 10"Ø SA D-7 VEST. REFER TO PLANS AND REFLECTED CEILING PLAN FOR 8"Ø D-6 D-6 JUVENILE EXACT LOCATIONS. D-8 D-6 175 140A D-7 D-5 215 215 INTERVIEW 8"Ø 8"Ø 215 CHD PLANS 175 375 141 Engineered 225 140 E- DUCT DIMENSIONS CALLED OUT ON DRAWINGS ARE INSIDE FREE Systems 2 AREA DIMENSIONS. ACOUSTICAL DUCT LINER ARE TO BE ADDED TO OVERALL MEASUREMENTS. Associates

OUTDOOR F- ALL DUCTWORK AND PIPING WHICH PASSES THRU FIRE RATED TO BE FIRE STOPPED WITH APPROVED FOAM OR 169 SEALANT. REFER TO SPECIFICATIONS FOR APPROVED SHEET NO. MECHANICAL FLOOR PLAN MANUFACTURES. SCALE: 1/8" = 1'-0" D NORTH M1.1 1 2 3 4 5 6