CLEANROOM EQUIPMENT & FURNISHINGS

Low-Cost Solutions for High-Tech Industries

© Copyright 2013 Terra Universal, Inc. Vol. 5, No. 17 Modular

Hardwall Cleanrooms (shown; see page 6)

• Acrylic, polycarbonate or dissipative PVC • Complex floor plans with internal partitions • Cleanliness to ISO 4, with A/C and negative pressure containment BioSafe® Steel Biopharmaceutical Cleanrooms (see page 10)

• Double-wall steel panels conceal plumbing, insulation • Smooth internal surfaces with radius corners are easy to clean and sterilize • Powder-coated or 304/316 stainless steel Softwall Cleanrooms (see page 18)

• Softwall anti-static vinyl curtains create a low-cost clean enclosure • Available casters for portability • Rigid steel frame supports ceiling fans without internal supports

Cover Photo: Hardwall Module with furnishings: Note: All prices and specifications are subject to change without Labconco Basic 47 (No. 3646-00, $2,321) notice. Crating charges apply to selected items. Call for information. WhisperFlow Hood (No. 1686-60C, $2,321) Stainless Steel Top Workstation (No. 1521-55, $1,324) ® 2013 Terra Universal, Inc. All rights reserved Cleanroom Polymer Cart (No. 1532-53A, $191) Printed in USA 031513 Room Pictured: Hardwall Acrylic ISO 7 Cleanroom Dimensions: Reference No. 131609 Room 1 11'6" x 9'8" x 9' Room 1A 8'2" x 6' x 9' Total Square Footage: 1391 Room 2 12'5" x 9'1" x 9' Room 3 16'10" x 11' x 9' Cost: $159,158 Room 4 19'7" x 16'10" x 9' Room 5 22' x 15' x 9' Room 5A 10' x 9'10" x 9' Convert any space into a controlled environment Room 6 19' x 15' x 9' at a fraction of the cost, in a fraction of the time!

To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 3 3 System Overview

Fully Integrated, Pre-Tested Turnkey Systems Terra’s integrated design and manufacturing know-how lets you specify not just a clean work environment, but a total production solution:

• Application-appropriate environment—Over 35 years of design and manufacturing experience in all areas of environmental control: particles, , static, temperature

• Work Stations— Ergonomic, space-saving, ultra-clean designs, including laminar flow and exhaust purification systems

• Storage Solutions— From wall-mount and benchtop dry boxes to high-volume automated stockers

• Gowning Area Furnishings—From the recognized industry leader in change room design and garbing protocol Freestanding steel structures span up to 24 feet without external supports.

How Clean is Clean? Guidelines for FFU Selection Class 1 and Class 10 applications require near-100% ceiling coverage of filter/ are usually expressed as a units (FFUs), producing a laminar flow of clean air traveling downward at range (see Table 1). Table 2: a velocity of about 90 feet/minute (measured 6" below the filter face). This Low-end figures within Recommended Ceiling Filter Coverage design ensures a positive pressure inside the cleanroom, which blocks the Class Ceiling Coverage each contamination class influx of contaminants and guarantees swift removal of particles generated by ISO 8 (Class 100,000) 5 - 15% generally indicate air people or process equipment. ISO 7 (Class 10,000) 15 - 20% velocity and air change ISO 6 (Class 1,000) 25 - 40% For less critical contamination requirements, experts correlate ventilation requirements for an “as ISO 5 (Class 100) 35 - 70% efficiency (i.e., the ability to remove contaminants and meet a cleanliness built” or “at rest” facility. ISO 4 (Class 10) 50 - 90% standard) with both the velocity of filtered air passing through the room and In the presence of higher ISO 3 (Class 1) 60 - 100%* also the number of air changes completed in a given time. The air-change figures degrees of contamination ISO 1-2 80 - 100%* more air changes are Note: Actual average velocity and air Table 1: required to maintain changes required may vary depending on the Recommended Air Velocity Rates the desired cleanliness application and floor plan. Class Average Airflow Velocity Air Changes standard. In fact, many * ULPA filters required in Class 1/10 IS0 14644-1 (Standard 209E) Per Hour manufacturers insist on as applications. HEPA filters required for all others. ISO 8 (Class 100,000) 0.005 - 0.041 m/sec (1 - 8 ft/min) 5 - 60 many as 720 air changes ISO 7 (Class 10,000) 0.051 - 0.076 m/sec (10 - 15 ft/min) 60 - 150 per hour to meet Class ISO 6 (Class 1,000) 0.127 - 0.203 m/sec (25 - 40 ft/min) 150 - 240 10 or cleaner requirements. Once you have established the required air ISO 5 (Class 100) 0.203 - 0.406 m/sec (40 - 80 ft/min) 240 - 600 change figure, use this formula to calculate the number of FFUs required: ISO 4 (Class 10) 0.254 - 0.457 m/sec (50 - 90 ft/min) 400 - 750 No. of FFUs = (Air Changes/Hour ÷ 60) x (Cubic ft. in room ÷ 650*) ISO 3 (Class 1) 0.305 - 0.457 m/sec (60 - 90 ft/min) 500 - 750 *CFM output of a loaded 2' x 4' FFU. ISO 1-2 0.305 - 0.508 m/sec (60 - 100 ft/min) 500 - 750 Note: Actual average velocity and air changes required may vary depending See TerraUniversal.com for full application guidelines. on the application and floor plan.

4 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Configuration Guidelines QuickQuote Planner Use this overview to help you select the Terra Modular Cleanroom quickly configures a system to your design for your application. specifications: www.TerraUniversal.com

USP <797> Compliant! See page 25 for systems configured for sterile compounding

Hardwall or Softwall Cleanrooms, All-Steel BioSafe® Modular Cleanroom (page 10) Full-View Plastic Panels The most effective design for bio-tech and pharmaceutical applications. Hardwall (page 6) – Select transparent acrylic, dissipative PVC , Lexan® or 304/316 stainless or powder-coated steel construction resists most solvents, polypropylene panels, which mount either externally or internally to create disinfectants and other cleaning solutions. Antimicrobial coatings and panel smooth, easy-clean surfaces. All-steel support frame for strength and easy gaskets create a germ-free environment. Radius corners and raised, drained installation — requires no external bracing. flooring available for disinfectant wash-down. Configure as a positive- or Softwall (page 14) – Many panel options, including anti-static vinyl and clear or negative-pressure room, with A/C and humidity control. frosted strip shields. All-steel supports available with casters.

Ceiling A/C with Plenum Air Return

Vertical Air Return Filtered Air (VAR) Filtered & Cooled Air

Air Conditioning Ventilation Room Modular HVAC units ensure comfort of garbed personnel. Double ceiling Ideal for safe removal of fine powders or chemical vapors. Adjustable ceiling allows energy-efficient recirculation to ceiling plenum. Dehumidification ventilator draws air upward through HEPA filters and/or exhaust ductwork. modules available. See page 22. Inlet filters ensure a clean working environment. Available for plastic or all-steel cleanrooms. See page 23.

Powder-Containment Room (page 12) Negative-Pressure Cleanroom Air recirculation zone draws powders away from work station into a dual HEPA Ceiling filter/fan units create laminar flow of particle-free air. Exhaust ductwork filtration system that protects both product and personnel. Adjustable air and adjustable air handlers create overall negative pressure to protect external handler creates overall negative pressure to protect the external environment. environment from pharmaceutical powders and biohazards. See page 23.

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 5 Hardwall Cleanrooms IonBar™— Terra’s Hardwall Modular Cleanrooms provide the rigidity and durability for a cleaner cleanroom of a freestanding room. All components are factory-assembled and Eliminates surface charges that tested before shipping, and on-site installation is usually completed in attract particles. See page 19. less than a day. Operation Status Indicator verifies Unlike other modular cleanrooms on the market which require FFUs are running complex suspended ceiling supports, Terra cleanrooms are completely free-standing structures.

Any size or floor plan!

Ordering Information Select Panel Mounts For Your Requirement — Internal-Mount Panels External-Mount Panels Use the catalog numbers below to specify the cleanroom style for your Smooth internal surface is easy to Includes mirror-finish 304 stainless application. Specified rooms include powder-coated steel frame, control panel, disinfect. steel control panel and mounting and wall panels of material specified. Select access door(s), ceiling modules and strips for a showcase room that’s also durable and easy to clean. other accessories to complete your system.

Plastic Hardwall Cleanrooms QuickQuote Planner Panel Material: Acrylic* Dissipative Polycarbonate Polypropylene quickly configures a system to your (see description at PVC specifications: www.TerraUniversal.com right) Cat. # Cat. # Cat. # Cat. # External Mount Panels 6600-00 6600-01 6600-02 6600-03 Internal Mount Panels 6600-05 6600-06 6600-07 6600-08 * Acrylic is damaged by alcohol and other cleaning agents. Cleanroom accessories begin on page 18 • Filter/Fan Units – HEPA/ULPA, low noise & vibration Recommended Filter/Fan Configurations (see pg. 18) • Lighting – fluorescent, teardrop, flow-through, UV Nominal No. of No. of Filter Modules to meet Fed Std 209 • Ionizing Modules – control ESD Dimensions Ceiling Class Standards Bays 1 10 100 1,000 10,000 100,000 • and Dehumidification Modules 8' x 8' 8 5 - 8 4 - 8 3 - 6 2 - 3 1 - 2 1 • Ceiling Ventilation Modules – for negative-pressure applications 8' x 12' 12 7 - 12 6 - 12 4 - 8 3 - 5 2 - 3 1 - 2 8' x 16' 16 10 - 16 8 - 16 6 - 11 4 - 6 2 - 4 1 - 3 Other Modular Cleanroom Styles 12' x 12' 18 11 - 18 9 - 18 6 - 13 5 - 7 3 - 5 1 - 3 • Softwall Plastic Cleanrooms – see page 14 12' x 16' 24 14 - 24 12 - 24 8 - 17 6 - 10 4 - 6 2 - 4 • BioSafe® All-Steel Cleanrooms – see page 10 16' x 16' 32 19 - 32 16 - 32 11 - 22 8 - 13 5 - 8 2 - 5 20' x 20' 50 30 - 50 25 - 50 18 - 35 13 - 20 8 - 13 3 - 8 • BioSafe® Powder-Containment Rooms – see page 12 USP <797> compliant models for sterile compounding—pg. 25

6 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Hardwall Options Access Doors Fan Filter Units Select among swing and sliding door designs, with stainless steel or aluminum frames and tempered glass, dissipative PVC or acrylic panels. Specialty configurations include fast- response roll-up designs and touchplate- activated doors. See page 8.

Swing door Aluminum frame sliding door

Fan/Filter Units (FFUs) and Lights HEPA and ULPA filters meet cleanliness standards to Class 10 (ISO 3). Many configurations available, including carbon units, for chemical vapor removal, and UV sanitation modules to eliminate germs. See pages 18 – 19.

Control Panel with Operation Status Indicators Mounted to the right of the access door, this panel allows convenient control of fan/filter units (FFUs), lights, ionizing modules, and other system options. Its mirror-finish contributes the showcase Operation Status exterior of the cleanroom. It includes a Indicators (OSIs) in Magnehelic® differential pressure gauge, each corner glow to indicate FFUs are in for easy monitoring of internal air pressure, operation Cleanroom Support Frame and an Operation Status Indicator (OSI) 3 The support frame is fabricated of interlocking 1 ⁄4" powder- in each corner, which provides a solid coated square steel uprights and cross sections. Ceiling members glow to indicate that FFUs are operating, 1 are welded to steel 3" x 1 ⁄2" T-bars, forming the 2' x 4' bays that and flashes to indicate they’re not. One support filters and lights. Vertical finishing strips, fabricated of required per cleanroom. mirror-finished 304 stainless steel, hold hardwall panels securely Panel with OSI 120VAC, 60Hz 220VAC, 50/60 Hz in place. Standard height is 7' measured from filter face to floor Cat. # Cat. # $/Each (8'3" with filter/fan unit), allowing installation beneath a standard For External-Mount Panels 6600-23 6600-23-220 772.00 9' ceiling. Other heights are available. For Internal-Mount Panels 6600-24 6600-24-220 772.00

Hardwall Panels Partitions and Air Locks (Antechambers) Standard 4'W x 7'H panels are available in four rigid materials: Air Lock serve as contamination buffer zones; as staging areas; or as gowning areas. Partitions create multiple clean zones to meet varying cleanliness requirements inside a Acrylic Panels offer economy, visibility and strength. Black single cleanroom. Call to specify configuration. Note: Partitions and air locks must be and amber panels are also available. Not recommended for specified when cleanroom is ordered. use with alcohol or other strong cleaning agents. Difficult to clean since they tend to attract and retain particles.. Static-Dissipative PVC Panels safely remove surface charges, Cleanroom Talk-Through protecting against potentially damaging ESD (electrostatic Ideal for cleanrooms, as well as laboratory and hospital isolation areas, discharge) as well as particulate attraction. Dissipative layers are the Talk-Through features a clean plastic frame and transparent mylar molecularly embedded for optimal durability. Surface resistivity: diaphragms that allow workers on both sides of a cleanroom wall to 106 - 108 ohms/sq. (ASTM-D257). communicate freely. Cat. # $/Each Polycarbonate resists many common acids, solvents and Model shown 5050-50 291.00 cleaning solutions. Polypropylene provides superb resistance to acids and other chemicals (see photo on page 9). Need it Fast? Terra's ValuLine™ Cleanrooms * Acrylic is not recommended for use with ship within a week! See page 17. alcohol and other cleaning agents. Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 7 B C

Hardwall cleanroom with internal-mount polypropylene panels for easy cleaning, A/C, A D and high speed CleanSeal® Roll-Up Doors Cleanroom C. Parting Strip Shields (see page 17) Access Door Options Available in standard vinyl or anti-static vinyl, these 4"-W strip shields can be mounted in place of a standard door or 4-foot wide Select among many door options to meet your clearance and cleanliness requirements, hardwall panel at any location along the perimeter of the cleanroom including rapid-response roll-up doors on page 9. or along an internal dividing wall.. Strip shields are not designed to A. Aluminum-Frame Swing Doors maintain pressure differentials between clean areas. This economical door comes with a choice of acrylic or static-dissipative panels. Dimensions: D./E. high-Speed Doors 36"/72"W x 81"H. Roll-Up Door (see facing page) B. Aluminum-Frame Sliding Doors operates at up to 42in/s, allowing These aluminum-frame doors slide open along an extruded aluminum track to an opening transfer of large equipment with of 36". Requires two 4-foot cleanroom panel widths for installation. Standard model slides minimal impact on cleanroom. open from right to left; specify left-to-right slide, if desired. Dimensions: 40"W x 82"H. Feature non-porous, non- shedding, non-absorptive and non-permeable PVC-coated Type Door Panel Single Door curtain. Operates under both Material (see photo) Cat. # $/Each positive and negative pressure. Bi- E A* Aluminum Swing Acrylic** 6710-14 1,213.00 Parting Door is made of seamless, A* Aluminum Swing Static-Dissipative PVC 6710-15 1,488.00 molded fiberglass. B Aluminum Slide Acrylic** 6704-02 2,270.00 Cat. # $/Each B Aluminum Slide Static-Dissipative PVC 6704-03 2,475.00 D. Roll-Up Door 6710-53A 12,098.00 * Standard swing is outward (away from cleanroom), mounted on right panel of shorter wall. E. Bi-Parting Door 6710-54 17,444.00 ** Acrylic is damaged by alcohol and other cleaning agents.

8 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com 304 Stainless Steel BioSafe® Cleanroom (page 10) with Air Shower (see page 54).

Multi-room hardwall cleanroom with polycarbonate panels

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 9 Complex Cleanrooms or Containment Labs with Modular Versatility and Economy — Ideal for Aseptic Processing!

BioSafe® All-Steel Bio-Pharmaceutical Cleanrooms • Smooth surfaces and radius corners eliminate germ traps for easy cleaning and sterilization • Pre-engineered, insulated panels provide thermal stability, dampen noise and vibrations, conceal wiring and gas lines • Available in powder-coated or 304/316 stainless steel, with antimicrobial surfaces and glass panels for full visibility of interior rooms Stainless steel BioSafe® Cleanroom, showing • hePA/ULPA filtration modules meet cleanliness ceiling ducts that direct recirculated air from requirements to ISO 4 (Class 10) in-panel returns to the air conditioning unit • Several HVAC options available, including modular units that circulate air to a ceiling plenum chamber or to ductwork that feed Terra’s modular BioSafe® Cleanrooms provide the flexibility to configure a floor plan and individual fan/filter units (see page 22) environmental controls to your production requirements—without the high cost, long lead times, special permitting and other project complexity associated with a conventional cleanroom. • Available EnergySaver fan/filter speed controls The two-piece design of BioSafe® steel panels provides the benefits of standard bio-cleanroom wall and exhaust fans simplify balancing of room construction in a completely modular, pre-engineered panel. pressures and air change rates (see page 19) Their unique design supports aseptic operations. All panel materials—powder-coated steel, 304/316 stainless steel, and tempered safety glass—stand up to frequent cleaning with standard • Snap-off panel design provides access to disinfectants, including DI water/alcohol solutions. Panel seams are caulked to eliminate cracks vacuum, gas, and electrical lines, as well as that could harbor germs and other contaminants. Radius bends on corner panels further facilitate insulation cleaning by providing smooth surfaces that are easy to wipe down. • Other options include pass-throughs, Because BioSafe® panels require no external bracing or other support, these structures typically humidification/dehumidification, ionization, require no special permitting and can be installed in a fraction of the time required for conventional and UV sterilization cleanrooms.

10 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Versatile BioSafe® panels accommodate complex cleanroom designs, with interior production rooms and gowning areas dedicated to your workflow and cleanliness requirements

Complex Cleanrooms or Containment Labs with Modular Versatility and Economy — Tempered glass windows and Ideal for Aseptic Processing! pass-throughs simplify access

BioSafe® Cleanrooms: Ordering Information Windows (specify quantity, size, location)

Use the catalog numbers below to specify the material for your application. Material Cat. # A Terra application specialist works with you to develop the floor plan, panel Tempered Glass 6600-45 heights and other configuration details you require. Standard 7'-high panels Fire-Rated Glass 6600-46 create a room that fits beneath a standard 9' ceiling. Select access door(s), ceiling Static-Dissipative PVC 6600-47 modules and other standard Terra cleanroom modules to complete your system. Polycarbonate 6600-48

BioSafe® Cleanroom Antechamber Internal Wall BioSafe® Cleanrooms: Special Designs Panel/Grid Material Cat. # Cat. # Cat. # Powder-Coated CR Steel 6600-30 6600-35 6600-40 Versatile BioSafe® panels and ceiling grids can be configured to meet a 304 Stainless Steel 6600-31 6600-36 6600-41 wide range of environmental requirements. 316 Stainless Steel 6600-32 6600-37 6600-42 Call to discuss your applications! Control Panel for BioSafe® Cleanroom allows convenient control of Fan/Filter Units, lights and other system controls. Operation Status Indicators in each corner display FFU operation. One required per cleanroom. Cat. # $/Each 6600-26 772.00 Fan Filter Units Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 11 BioSafe® POWDER Containment Room The ideal enclosure for pharmaceutical handling — 3 Purity testing 3 Weighing 3 Packaging 3 Chemical analysis • recirculation module creates a HEPA-filtered clean zone • rear-mounted air vents draw air and powders away from operator and work area • rear manifold recirculates air through HEPA filters for a continuous wash of particle-free air to the work area Powder-coated steel Powder Containment Room equipped with full-width strip shields • Broad access area, with parting vinyl strip shields, allows easy access, even pallet loading of large containers 304 Stainless Steel Powder • BioSafe® all-steel construction ensures a strong, free- Containment standing structure that is easy to clean and sterilize Room (see page 10) • Add ceiling filter/fan units to meet cleanroom conditions throughout the room

Terra’s Powder Containment Room captures powders generated during Rear-mount packaging and weighing processes, while providing a contamination- manifold draws free working space. air away from work area into Unlike conventional cleanrooms, it features a versatile air handling ceiling HEPA system that lets you configure the working space for your requirements filter unit (see illustrations below). Powder Containment Booth Cat. # Neutral Pressure Room: 100% Air Recirculation (Fig. A) Powder-Coated Steel 6600-75 Configured as a neutral pressure room, this system ensures 100% 304 Stainless Steel 6600-76 recirculation of exhausted air and complete protection of the 316 Stainless Steel 6600-77 external environment. CleanZone Recirculation System Cat. # $/Each Positive Pressure Room: Filter/Fan Units (Fig. B) Includes exhaust filter housing, ductwork, and FFU 6600-84 1,807.00 adapter collar, and adjustable fresh air . Order This additional protection optimizes product purity by outlet filters (2) and FFU separately. Exhaust-only module also controlling airborne aerosols, microbes, and other submicron available at TerraUniversal.com particles.. Outlet HEPA Filter Cat. # $/Each Two required per CleanZone Module 1681-02 363.00 Negative Pressure Room: Exhaust Ventilation (Fig. C) For additional protection of personnel inside the room, the Reduces flow to 500 CFM (70 ft./min). Less restrictive MERV 14 filter available. CleanZone Recirculation System lets you adjust the percentage Power: 115VAC, 50/60Hz; 230VAC (50Hz also available) of air recirculated into the containment room. Airflow: 500 CFM (with HEPA filter) Filters: (2) 99.99% efficient HEPA, 27" x 13" x 2"(rated @ 0.3µm particle diameter) Filter/Fan Units, See page 18 (Room-side replaceable recommended) Exhaust Flange Adapter Panel 3" stainless steel flange available in several diameters to allow connection of exhaust . Select model with damper to adjust airflow.

Modular Design Adjusts for Your Requirements — CleanZone Air Return (see photo at right) A A A B D B D B C C C HEPA-Filtered Air

Contaminated Air

A* 99.99% efficient HEPA filter/fan unit B* return duct directs air E flow away from operator C* exit HEPA filters D filter/Fan Units – create positive pressure of filtered air (order separately) E – exhausts Fig. A. Neutral Pressure Room: Fig. B. Positive Pressure Room: Fig. C. Negative Pressure Room: air to create a negative Protects Outside Lab Protects Product Protects Personnel pressure (order separately) CleanZone Recirculation System creates Addition of ceiling HEPA filter/fan units Optional Air Handling Module expels air to a HEPA-filtered clean zone that captures create a negative pressure that pulls air away * Standard component of creates a positive pressure of filtered air CleanZone System hazardous powders, protecting the external to prevent airborne contaminants from from the personnel. Operates with or without environment. ceiling FFUs. entering the access area. 12 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com No. 6601-90, $16,938 No. 6602-91, $18,272 20’ x 10’ x 10’H with swing door, 20’ x 10’ x 10’H acrylic with polypropylene acrylic panels, three lights modesty panels, swing door, three lights Modular Offices • Convert any office or production space into a clean environment! Terra’s modular cleanroom design allows fast, economical installation of clean • Acrylic or dissipative PVC wall panels allow full visibility (ceiling office space anywhere in your facility. Select hardwall (show above) or softwall to floor or with opaque modesty panels) designs, in height up to 12 feet (floor to ceiling). Terra provides freestanding rooms or structures that bolt to an existing wall; call to discuss your requirement. • modular power system allows addition of fan/filter units to meet What could be more convenient—a room you install in hours and plug into a cleanliness standards (ISO 4 – 8) single 120VAC power outlet!

ISO 7 enclosure for Thermal ISO 7 enclosure for Anechoic Vacuum Chamber (Ref. No. 169906) Chamber (Ref. No. 169906)

ISO 6 enclosure ISO 6 4.5' x 36'D x 7'H static-dissipative PVC for automated enclosure for automated transfer conveyor, transfer conveyor showing conveyor access/maintenance ports (Ref. No. 178113) (Ref. No. 178113, $27,353) Cleanroom Equipment Enclosures • hardwall or softwall designs (ISO 4 to ISO 8) Terra modifies standard frame and ceiling designs to meet your custom requirements, including special interface ports, process conveyors, power or • Special cut-outs and access doors accommodate power lines, other facility pass-throughs, and unique ceiling configurations. entry/exit ports, interface modules Call to discuss your application!

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 13 Softwall Cleanrooms Operation Status Indicator verifies Terra’s Softwall Modular Cleanrooms provide an economical, FFUs are running versatile solution to clean manufacturing requirements in semiconductor, medical device, and many other industries. Portable, expandable, and easy to assemble/disassemble, these cleanrooms are also available on an accelerated delivery program to meet your tight production schedule!

Unlike other modular cleanrooms on the market which require complex suspended ceiling supports, Terra cleanrooms are completely free-standing structures.

Softwall Support Frame The support frame is fabricated of 1 interlocking 2 ⁄2" powder-coated square steel uprights, cross sections, and ceiling members. Ceiling members are welded to steel T-bars, Softwall Curtains forming the 2' x 4' bays that support filters and & Strip Shields lights. Corner reinforcement gussets ensure a rigid Softwall panels are fabricated of heavy-duty, structure. Optional heavy-duty casters allow easy Ask about blur-free 40 mil material—double the industry repositioning after installation. Standard height is Terra’s ValuLine™ standard—ensuring enhanced tear resistance and 7' measured from filter face to floor (8' 3" overall), eliminating the need for unsightly sewn sash weights. Strip allowing installation below a standard 9' ceiling. Cleanrooms—clean shields, made of 40-mil material, come standard in 12" widths, with 2" performance at overlap, for easy entrance or exiting. Polyurethane shields are 12"W, Note: Walls over 8' long require an additional lower cost! 40 mil thick. vertical support member. Curtains and strips are available in three materials, in either clear or frosted appearance. See pg. 16 for ordering information. Ordering Information Softwall Curtains and Strip Shields Use the catalog numbers below to specify the cleanroom style for your Order curtains and strip shields from pages 16 – 17. Curtain material is 40-mil application. Based on your desired floor plan, a Terra application specialist thick, clear PVC (anti-static PVC and polyurethane curtains also available). For will quote you on a room configured for your application. access doors, select alternating clear and frosted strip shields, which eliminate cling for easy parting. Frame Kit For 7'-high cleanroom, curtain length of 6'6" is recommended to allow Includes a powder-coated steel frame of the dimensions you specify. Standard adequate air exhausting. See formula on facing page for more information. height is 7'; other heights available. Walls over 8' long require an additional vertical support member. Includes a control panel for operation of filter/fan units, lights, and other selected options. QuickQuote Planner Cat. # quickly configures a system to your Powder-Coated Steel 6600-60 specifications: www.TerraUniversal.com 304 Stainless Steel 6600-61

Recommended Filter/Fan Configurations Cleanroom accessories begin on page 18 Nominal No. of No. of Filter Modules to meet Fed Std 209 • Filter/Fan Units – HEPA/ULPA, low noise & vibration Dimensions Ceiling Class Standards • Lighting – fluorescent, teardrop, flow-through, UV Bays 1 10 100 1,000 10,000 100,000 • Ionizing Modules – control ESD 8' x 8' 8 5 - 8 4 - 8 3 - 6 2 - 3 1 - 2 1 • Ceiling Ventilation Modules – for negative-pressure applications 8' x 12' 12 7 - 12 6 - 12 4 - 8 3 - 5 2 - 3 1 - 2 8' x 16' 16 10 - 16 8 - 16 6 - 11 4 - 6 2 - 4 1 - 3 Other Modular Cleanroom Styles 12' x 12' 18 11 - 18 9 - 18 6 - 13 5 - 7 3 - 5 1 - 3 • Hardwall Plastic Cleanrooms – see page 6 12' x 16' 24 14 - 24 12 - 24 8 - 17 6 - 10 4 - 6 2 - 4 • BioSafe® All-Steel Cleanrooms – see page 10 16' x 16' 32 19 - 32 16 - 32 11 - 22 8 - 13 5 - 8 2 - 5 • BioSafe® Powder-Containment Rooms – see page 12 20' x 20' 50 30 - 50 25 - 50 18 - 35 13 - 20 8 - 13 3 - 8

14 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Softwall Options

Casters Stainless steel swivel casters feature nonshedding polyurethane wheels. Capacity: 300 lbs. each. Order one per vertical post Price includes installation. Cat. # $/Each 6"-diameter locking caster 6704-08 158.00 3 (Raises cleanroom 7 ⁄16") Dual-Lock Strips For sealing curtains or strip shields to frame supports or overlap areas, Terra offers non- particulating, clear 3M Dual-Lock with plasticizer-resistant adhesive. These strips are ideal for application along the vertical frame uprights or along the vertical length of a curtain or strip, allowing corner or overlap attachment that minimizes air leaks. Price includes sewing of mating strips to specified curtains. Use quantity to specify desired number of feet. Cat. # $/Linear ft. Dual-Lock Strip 6704-05 13.00 Flexible Magnet Strip Self-Closures Flexible, chemical-resistant magnet strips are ideal for a variety of custom closure needs. Price includes sewing to specified curtain. Use quantity to specify desired number of feet. Cat. # $/Linear ft. Magnet Closure 6704-06 12.00 Snap-Tite™ Clips Ideal for securing two curtains together. Each two-piece plastic clip snaps together through holes in the curtains. Cat. # $/2-piece set 6704-07 2.00 Control Panel with Status Operation Indicators To order curtains, Includes panel with FFU and light control, as well as one FFU status indicator at each corner see next page. (see photo). Cat. # $/Each Cleanroom-Grade Vinyl is non-particulating and low . 6600-25 717.00 Static-Dissipative Vinyl is manufactured with permanent built-in Adjustable Uprights static inhibitors that will not wear off. Allow up to 18" vertical height adjustment during installation. For rooms up to 8' x 8' only. Non-outgassing Panels are made from inherently static- Cat. # $/Upright dissipative polyurethane that provides permanent, humidity- 8' Upright 6600-66 331.00 independent ESD protection for sensitive manufacturing conditions. Polyurethane contains no plasticizer, making it non- outgassing. Selecting the proper panel length Softwall panels and strip shields attach to the support frame All softwall cleanrooms require some gap between the curtain and the floor to allow by means of a unique noncontaminating Grip-Track™ mounting air to escape. If this gap is too narrow to accommodate the flow of air generated by system that eliminates cracks and seams where germs or particles the ceiling filter fans, then curtains and strips will billow outward. If it is too big, the can collect. Other mounting systems are available. cleanroom will not maintain adequate positive pressure. Note: Softwall curtains are notched to ensure a snug fit at all In general this formula helps you determine how long the curtains should be: corners. In standard installations, curtains are supplied in lengths Gap between curtain and floor = total surface area of filters in ceiling grid –––––––––––––––––––––––––––––––––––––––––––––––– of four feet. Where two curtains meet, the curtain panels overlap Perimeter of cleanroom by 6". To prevent personnel from parting curtains at these seams, For a 16' x 16' cleanroom with 7 ceiling filter fans, this gap should be about 10.5" (56 order optional curtain seaming, Dual-Lock, magnetic closures, or sq. ft. of filter ÷ 64 ft. (perimeter) = .875 ft. gap). This is exactly the gap produced attachment clips at right. See following pages for more information. when a 6' curtain is installed on a standard cleanroom frame, since the curtain bead Strip Doors is mounted about 1.5" below the filter face (6'10.5" above the floor). If the same cleanroom included casters, which raise the cleanroom about 7", then a 6'6" curtain Strip shields can be ordered in convenient widths to create access would be appropriate. doors for softwall or hardwall cleanrooms. By alternating strips of clear vinyl with frosted vinyl, you eliminate both sticking and air Refer to curtain ordering chart on the following pages to select the curtain height for gaps, creating entrances that are cleaner and easier to walk through. your application. The plastic curtain material is easy to trim to the exact size you require. Note: Strip doors are free-hanging—standard installations do not include attachment of the two sides to adjacent curtains or frame. • Grip- Track™ opens and closes without tools for easy panel mounting. IonBar™— • Smooth profile in closed position won’t for a cleaner cleanroom harbor contaminants Eliminates surface charges that attract particles. See page 18.

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 15 S oftwall Curtains and Strip Shields • Suitable for all classes of cleanrooms and all levels of process isolation • Available in anti-static PVC and nonoutgassing, static-safe polyurethane • Standard one-piece Grip-Track™ mounting system is easy to clean, eliminates exterior crevices where contaminants can collect • heavy-gauge materials hang straight, without the need for sewn hems or cumbersome sash weights • t-Grid Mounting System allows suspension of curtains or strip shields from existing cleanroom T-grids • Industry-leading fabrication and mounting technology gives you the cleanest, most durable curtains and strip panels available Garments courtesy of • Ideal for creating partitions inside a hardwall or softwall enclosure Clear Strips W. L. Gore & Associates These softwall curtains and strip shields are ideal for use with Terra’s free-standing Select the panel material to meet your application requirements. Static- Softwall Cleanrooms on the previous pages. They can also be installed directly Dissipative PVC includes permanent built-in static inhibitors that, unlike topical onto existing walls or ceilings using the versatile Grip-Track™ mounting system. treatments, will not wear off. Tests performed per ASTM D257 show surface resistivity of 10 Either way, you receive the cleanest, most durable panels available. 1.8 x 10 ohms/sq. Standard softwall curtains are fabricated of heavy-duty, blur-free 40 Terra also offers panels made from static-dissipative polyurethane that mil material—double the industry standard—ensuring enhanced tear provides permanent, humidity-independent ESD protection from sensitive resistance and eliminating the need for unsightly sewn sash weights. manufacturing conditions. This material contains no plasticizer, making it Strip shields, made of 60 mil vinyl, come standard in 8" widths, with 2" overlap, virtually non-outgassing. to form parting doors or reach-throughs. Polyurethane shields are 40 mil x 12" W.

Grip- Track™ Suspended T-Grid Mount (standard) Available for the Grip-Track™, the T-Grid mount Bi-Folding Eliminates all cracks and allows suspension of a curtain from standard Curtain Mount crevices where dust & T-grid ceiling without the need for ceiling Available in anodized germs can collect. disassembly. Perfect for partitioning a hardwall aluminum or stainless steel, One-piece mounting or softwall cleanroom into multiple clean zones, this system allows softwall track, made of rigid or for establishing temporary isolation areas! curtains to be easily Cat. # $/Linear Ft. white polyethylene, retracted or extended For 2" Ceiling Grid Supports 6704-23A 3.00 along a heavy-duty, smooth Smooth profile in closed position incorporates flexibleFor 1.5" Ceiling Grid Supports 6704-24A 3.00 won’t harbor contaminants hinge and bottom rolling track. Contact Terra flanges. Snaps open for ordering information. and shut for quick, easy assembly. Compatible with T-Grid • Dual-Lock Strips Mount for use with existing ceiling T-grids. Non-corrosive • magnetic Strip Self-Closures and easy to clean. Cat. # $/Linear Ft. • Snap-Tite™ Clips Replacement Grip-Track™ 1322-60 8.00 See page 15 for ordering details

O rdering Guide 4' strip shield door Pricing is per linear foot. Use quantity to indicate the length in feet of the curtain or strip panel (e.g., quantity 8 = an eight-foot run of material of the specified height). 4' curtain 20' 4' curtain Grip-Track™ mounting is standard. with corner with corner notch notch Please note these construction details: • Standard curtains come in 4-foot wide panels, which are mounted to create the run specified. Strip shields come in overlapping 8" wide strips. Curtains in 4-foot Bead • Corners are notched to ensure a snug fit against frame corners. sections 20' • Adjacent panels overlap by 6", which generally provides an adequate .

Type For Ceiling Anti-Static Vinyl Polyurethane Height (non-outgassing) 6" Curtain overlap Cat. # $/Linear Ft. Cat. # $/Linear Ft. 4' curtain Curtain Panel (40 mil) Up to 8 ft. 1320C-08 49.00 1320-30 127.00 4' curtain with corner with corner Up to 10 ft. 1320C-10 59.00 1320-34 143.00 notch notch Strip Shield (60 mil) Up to 8 ft. 1320S-08 49.00 1320-67 154.00 Up to 10 ft. 1320S-10 59.00 1320-71 175.00 T ypical configuration for a 76-foot run of panels, plus a 4-foot strip shield door

16 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com valuline™ softwall modular cleanroom

Value without compromise! Clean conditions—to ISO 5/Class 100—at lower cost. All models ship within a week with only 3 - 4 day shipping on standard configurations!

• Create an economical cleanroom in nearly any office or Specifications production space in just a few days! Construction: • the ideal environment for material testing, processing and Frame and Grid: Powder-coated steel: 2.5” square tube uprights packaging, as well as enclosing particle-sensitive equipment and frame Panels and strip shields: Anti-static PVC, 40 mil (panels), 60 mil (strips) • ten standard sizes come preconfigured to meet cleanliness requirements from ISO 5 – ISO 8 (Class 100 – Class 100,000) Fan Filter Units: 2’ x 4’ HEPA, 3 speeds (see page 18) Lighting: 2' x 4', 4-tube fluorescent fixture, 3409 • All-steel support frame and ceiling grid creates a rigid, free- candlepower, 120 W, 120-277VAC standing support structure Power Supply Unit: Switched supply to six-receptacle unit for • hePA Fan Filter Units (FFUs) provide up to 808 CFM (at connection of up to 3 FFUs and lights, plus one high speed) non-switched 120V outlet, cord and 3-prong plug. Each plugs directly into a free 120VAC, 60Hz, 20A • fluorescent Light Modules provide 3409 candlepower each circuit (220V models available). • Power Supply Unit includes On/Off power switch, 120V power Ceiling Panels: Polypropylene outlet, and cord - plugs into standard 20A wall circuit Cat. # $/Each • Pre-drilled, pre-kitted components for easy installation ValueLine Softwall Modular Cleanroom 6600-66-VL Call TUI • Select optional casters for easy positioning Cleanroom Casters Terra Universal's ValueLine™ Softwall Cleanrooms provide low-cost contamination control, creating an ISO 5 – ISO 8 environment nearly anywhere Stainless steel swivel casters feature nonshedding you need clean areas, and standard configurations ship in just 3 – 4 days. polyurethane wheels. Capacity: 300 lbs. (136 kg.) each. Order one per vertical post. Price includes Choose among ten standard sizes, each preconfigured to meet a specific installation. Casters raise the frame 7.125" (181 cleanliness requirement. Parting strip-shield entries can be positioned at any mm). If casters are ordered with a cleanroom, the corner. Each model includes everything you need—even a tool kit—to get frame will be made shorter to keep the floor to your system up and running in a few hours (two assemblers required). All filter face dimension to specification. Casters add electrical components, including Fan Filter Units, are UL listed. one day to cleanroom lead time. ValuLine Softwall cleanrooms are configured for quick shipment, usually in Cat. # $/Each one week. For other sizes or custom configurations, see page 14. 6704-08 158.00

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 17 WhisperFlow™ Fan/Filter Units (FFUs)

• low-profile design allows installation inside cleanrooms with standard 9-foot ceilings • Quiet, low-vibration design: only 50 dBA, measured 30" from filter face @ 90 FPM • Provides an average airflow velocity of 90+ feet per minute (.45+ m/sec) and airflow of 640+ CFM under filter load at medium speed (2' x 4' model) • three-speed switch provides simplifies air balancing (see facing page for Energy Saver Control System) • meets IEST Recommended Practices Internal baffling and diffuser-panel ensure Select All Models uniform face velocity Models on this page

These reliable, self-powered Fan/Filter Units provide a uniform flow of Advanced baffling technology ensures uniform airflow across the filter microfiltered air to meet cleanliness standards down to Class 10 (ISO 4). face and attenuates sound. Select HEPA (High-Efficiency Particulate Air) All models use a 3-speed, centrifugal-type fan/motor with permanently filters, rated 99.99% efficient at removing particle ≥ 0.3 microns, or ULPA lubricated bearings mounted inside a white powder-coated steel housing with (Ultra-Low Penetration Air) filters, rated 99.9995% efficient at removing drop-in prefilter (stainless steel available) particles ≥ 0.128 microns. Provides years of no-maintenance, 24/7 operation, depending on your air quality. All prices below include installation on a specified Terra modular cleanroom. Filter Fan Units (HP: high speed; MS: medium speed; LS: low speed) Model Dimensions Wt. Avg. Airflow ft/min Run Amps Watts Power With HEPA Filter With ULPA Filter Inches Lbs. CFM* (m/s) @ 60Hz 3 (mm) (Kg) m /hr HS MS LS HS MS LS Cat. # $/Each Cat. # $/Each 23.63 x 47.63 x 12.51 71 717 115 102 93 4.3A 3.5A 3.3A 120VAC, 60 Hz 6601-24-H 740.00 6601-24-U 845.00 2 x 4 (600 x 1210 x 318) (32) (1218) (.58) (.51) (.47) (512W) (416W) (393W) 220VAC, 50/60 Hz 6601-24-H-220 845.00 6601-24-U-220 950.00 23.63 x 35.63 x 12.51 53 602 121 116 106 4.1A 3.1A 2.7A 120VAC, 60 Hz 6601-23-H 740.00 6601-23-U 845.00 2 x 3 (600 x 905 x 318) (24) (1023 ) (.61) (.59) (.54) (500W) (378W) (329W) 220VAC, 50/60 Hz 6601-23-H-220 845.00 6601-23-U-220 950.00 23.63 x 23.63 x 12.51 44 558 172 166 162 3.9W 2.8A 2.4A 120VAC, 60 Hz 6601-22-H 740.00 6601-22-U 845.00 2 x 2 (600 x 600 x 318) (20) (948) (.87) (.84) (.82) (472W) (339W) (290W) 220VAC, 50/60 Hz 6601-22-H-220 845.00 6601-22-U-220 950.00 * At medium speed Special Fan Filter Unit Configurations Visit TerraUniversal.com for further application guidelines, Room-Side Replaceable FFUs operating specifications, and ordering information on these Available with both HEPA and ULPA filters, lines of innovative clean air solutions. Room-Side Replaceable (RSR) models allow filter Low-Energy replacement from the inside of the cleanroom. DC Fan Filter Units Because it eliminates the need for roof access or These Fan Filter Units incorporate breaching the cleanroom, an RSR model greatly electronically commutated (EC) reduces maintenance time and costs. To service Gel channel that seals against motors, a proprietary baffling the filter, you simply rotate retaining clamps and “knife” edge on fan housing. system and backward-inclined lower the gel-sealed filter unit away from the fan module, which remains in place in the ceiling fans to reduce lifetime cost grid structure. The new filter seals against the “knife” edge of the fan housing. of ownership and increase operational performance. Using a smart control system, these consume RSR With HEPA Filter With ULPA Filter Fan Filter Units only 95 watts @90 FPM – greatly reducing cleanroom operating costs. Cat. # $/Each Cat. # $/Each 2’ x 4’ 6601-24-HR 1,040.00 6601-24-UR 1,145.00 They can help earn LEED (Leadership and Energy and Environmental 2’ x 3’ 6601-23-HR 1,040.00 6601-23-UR 1,145.00 Design) points, further reducing operating cost. They generate less heat 2’ x 2’ 6601-22-HR 1,040.00 6601-22-UR 1,145.00 and noise than AC FFUs, and they provide a much wider flow range, from 110 to 980 CFM, making them ideal for applications involving high static pressure. Explosion-Proof FFUs UL-listed for Class I or Class II, Division 1 as specified by the NEC. The direct-drive, Low-Energy With HEPA Filter With ULPA Filter 0.25 HP fan-cooled, non-sparking motor is designed for continuous-duty DC FFUs Cat. # $/Each Cat. # $/Each operation. Selection of this unit includes installation of filled rigid conduit and 2’ x 4’ 6601-24-H-DC 1,148.00 6601-24-U-DC 1,248.00 wiring throughout the enclosure. 2’ x 3’ 6601-23-H-DC 1,148.00 6601-23-U-DC 1,248.00 2’ x 2’ 6601-22-H-DC 1,148.00 6601-22-U-DC 1,248.00 Explosion-Proof With HEPA Filter With ULPA Filter FFUs Cat. # $/Each Cat. # $/Each Stainless Steel FFUs 2’ x 4’ 6601-24-HE 2,960.00 6601-24-UE 3,065.00 304 stainless steel housings are available for most FFUs listed on 2’ x 3’ 6601-23-HE 2,960.00 6601-23-UE 3,065.00 these pages. 2’ x 2’ 6601-22-HE 2,960.00 6601-22-UE 3,065.00 18 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com New Wireless Cleanroom Control— Feature! Remote Access to Savings! Terra’s latest-generation Wireless Cleanroom Control System offers convenient power management to optimize efficiency and cut operating costs. • turn off lights and air conditioning system and put fan filter unit in energy-saving mode at the press of a button on your mobile device • Set up automatic scheduling to control cleanroom operation (FFUs, lights, temperature) based on your operating hours • A/C and other energy cost savings on weekends and off-hours provide fast ROI (typically within a year) • remote Internet monitoring and control – check operation and make changes from home • Simple operation via SmartPhone – as easy as setting your home • Priced so reasonably that you can’t afford not to include it, even with simple cleanrooms! Call Terra for more information on how the Wireless Cleanroom Control System can work for you!

EnergySaver FFU Control System • Variable speed FFU control reduces energy costs – pays for itself in less than two years! • Simplifies cleanroom air balancing and cleanroom validation: lets you fine-tune air speed and flow volume room by room without breaching the cleanroom ceiling • Night setback mode maintains cleanroom integrity at lower fan speeds to save energy and cut heat generation when room is unoccupied This versatile control system includes a EnergySaver Module that controls power to all FFUs in a single Powder Distribution Module (see above), allowing you to ramp fan speed up and down to attain the precise air flow and velocity levels for your application. This variable control is ideal for incremental adjustments required in final cleanroom air balancing and validation, and it eliminates the need to breach the ceiling panels in order to adjust FFUs manually. It also allows compensation for clogging filters. EnergySaver Console Each operates up to 25 EnergySaver Controllers, handling up to 100 FFUs. Price EnergySaver Console includes programming of FFU zones. Cat. # $/Each EnergySaver FFU Controller 6602-23 693.00 One required for all FFUs in a single Power Distribution Module (see above). One required/Console. EnergySaver Power Supply Cat. # $/Each For 120VAC 6702-31 63.00 For 120VAC 6602-20 520.00 For 220VAC 6702-31-220 63.00 For 220VAC 6602-20-220 572.00

Exhaust Fan/Filter Units IonBar™ Ionizing Bar with Eliminates surface Remove Microcontaminants Generated FFU Installation Kit charges generated Inside a Cleanroom by laminar flow for a Generates a balanced stream of positive cleaner cleanroom These reverse-flow fan filter units are ideal and negative ions to neutralize surface for rooms where powders, aerosols or fine static charges, protecting sensitive parts dust is generated. The exit HEPA filter safely against ESD and eliminating surface removes micro-contaminants down to 0.3µm from the air exhausted from the attractions that make cleaning difficult. cleanroom. The perfect way to contain a potential environmental contaminant! Its low-voltage design is intrinsically safe. More Ventilation Solutions—see page 23. For FFU Size For 120VAC, Exhaust With HEPA Filter With ULPA Filter (No. of emitters) 60Hz FFUs Cat. # $/Each Cat. # $/Each Cat. # $/Each 2’ x 4’ 6601-24-HV 1,040.00 6601-24-UV 1,145.00 2' x 4' (8) 2005-49 771.00 2’ x 3’ 6601-23-HV 1,040.00 6601-23-UV 1,145.00 2' x 3' (6) 2005-48 675.00 2’ x 2’ 6601-22-HV 1,040.00 6601-22-UV 1,145.00 2' x 2' (4) 2005-47 563.00 FFU Vapor-Removal Adapter Ducted Filter Modules Photo-Catalytic Oxidation (PCO) HEPA/ULPA Modules Allow Easy System Removes Chemical Vapor Attachment to In-House Air Handler This filtration system provides triple These filter modules include a 12” x 2”H collar Order FFU cleaning: UV lights kill bacteria, viruses and separately for attachment to an air handler or other air mold; a Photo-Catalytic Oxidation (PCO) source, which determines flow rate. Internal baffling system and diffuser plate panel removes organic vapors; and the FFU removes sub-micron particles. An ensure uniform face velocity. Additional models available for room-side filter activated charcoal pre-filter enhances vapor removal. replacement or remote damper adjustment; see TerraUniversal.com. Cat. # $/Each Ducted Filter With HEPA Filter With ULPA Filter WhisperFlow™ FFU Adapter Housing 6602-30A 415.00 Module Cat. # $/Each Cat. # $/Each Charcoal Pre-Filter 6602-35A 158.00 2’ x 4’ 6601-24-HD 380.00 6601-24-UD 480.00 UV Sanitizing Module* 6602-40 404.00 2’ x 3’ 6601-23-HD 380.00 6601-23-UD 480.00 PCO Panel 6602-36 595.00 2’ x 2’ 6601-22-HD 380.00 6601-22-UD 480.00 * Two required Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 19 Fluorescent Lights • make it easy to configure the optimal lighting for your application • Select 2 x 4 ceiling module for placement in the ceiling grid, or Teardrop Lights for installation below the grid • flow-Through units are ideal with dense FFU ceiling coverage

A. 2' x 4' Ceiling Module This 2' x 4' painted steel housing includes four fluorescent light tubes, providing 4,560 foot candles. Price includes installation (specify desired location when ordering). A B B. Teardrop Lights Ideal for Class 1 or Class 10 cleanrooms, in which near-100% filter Ordering Information Fluorescent Illuminators coverage of the ceiling leaves no space for standard fluorescent Module Type Intensity 115VAC, 60Hz 277VAC, 60Hz light modules. Aerodynamic design ensures minimal interference (Candela*) Cat. # $/Each Cat. # $/Each of the laminar airflow. Dimensions: 48"L x 2"D x 6"H. Price includes A. 2' x 4' Ceiling Module 3,409 3800-80 205.00 3800-80 205.00 installation (specify desired location when ordering). B. Teardrop Light (48"L) 230 6704-15A 409.00 6704-15 409.00 C. Flow-Through Module (not shown) C. 2' x 4' Flow-Through Module 2,355 6704-77 972.00 6704-77-277 1,076.00 * Candela (candlepower) is an expression of intensity at the light source. To calculate foot Low-profile, fluorescent-tube module stacks beneath a 2' x 4' FFU. candles at your work surface, divide candlepower by the square of the distance from light 3 Adds 4 ⁄4" to ceiling height. Intensity: 3,150 foot candles. to surface: Easy-Clean Light Guard Candlepower Foot Candles = Fits beneath any 2' x 4' ceiling fixture to allow easy cleaning with most at Work Surface (Distance from Light to Workspace)2 disinfectants. Transparent polycarbonate panel transmits virtually 100% of light. Includes chemical-resistant, noncontaminating gasket. Fluorescence-Detection UV Illuminator Cat. # $/Each 2' x 4' fixture contains four 365nm UV tubes for fluorescence detection. 3800-25 156.00 Operates on 115VAC or 277VAC, 60Hz power.. Germicidal UV Illuminator Cat. # $/Each 2' x 4' fixture contains four 254nm UV tubes for germicidal control. 3800-27 496.00 Operates on 115VAC or 277VAC, 60Hz power. Includes occupancy EnergySaver Light Control System safety senser. Allows centralized on/off light control to reduce energy when room is Cat. # $/Each unoccupied. Order console on page 23. 3800-26A 1,850.00 Cat. # $/Each 120VAC 6602-22 415.00

Ceiling Panels Cat. # $/Each Clear Acrylic 6704-19 62.00 • Cover unused 2' x 4' bays in the ceiling grid Clear Static-Dissipative PVC 6704-21 105.00 White Polypropylene 6704-20 62.00 • each panel seals against gaskets included in the Stainless Steel 6704-79 105.00 grid frame

Cleanroom Flooring Standard Terra cleanrooms are designed for placement on existing floors. Terra also provides several flooring solutions for various requirements: • Raised Flooring — Stainless steel or encapsulated aluminum (solid and perforated panels). • Contamination-Control Floor Coverings — remove even the finest particles of foot-borne contamination simply and effectively, without tacky carry-over. The renewable polyester- compound surface, available in blue or gray, holds up to years of use and can be cleaned with standard cleaning solutions (general purpose and bactericides available from Terra). Call Static-Dissipative Clean-Zone Floor for a quotation for your facility. Covering, Cat. # 3801-16 • Other Solutions: Call to discuss your requirements of other floor materials, including ESD-safe vinyl floor tiles.

20 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Cleanroom Dehumidification Modules • extends shelf life of pharmaceuticals, semiconductor components, food products, and other sensitive materials • Provides the humidity stability required by FDA and other regulating agencies • regenerating silica gel desiccant system produces dry air flow between 50 and 300 CFM These low-maintenance systems feature silica gel desiccant housed in a rotor. Moisture in the process air passing through the rotor is adsorbed, producing a flow of dry air. Concurrently, reactivation air is heated and passed through the rotor to regenerate the silica gel and ensure continuous operation. The humid regeneration air is then ducted outside the cleanroom. Adsorption Rate No. 6710-60 No. 6710-61 No. 6710-62 70ºF @ 50% RH 1.1 lbs./hr. 3.3 lbs./hr. 6.6 lbs./hr. 70ºF @ 30% RH 0.8 lbs./hr. 2.5 lbs./hr. 5.0 lbs./hr. 70ºF @ 10% RH 0.3 lbs./hr. 0.9 lbs./hr. 1.8 lbs./hr.

Cleanroom Dehumidification Modules (240/3/60 and 480/3/60 voltages also available) Dimensions Process Reactivation Weight Full Load Reactivation Power Voltage (W x D x H, inches) Air Flow Air Flow Amps Heat Consumption Cat. # $/Each 29.75 x 15.25 x 22 50 CFM 15 CFM 85 lbs. 12 3,240 BTUH 1,400 Watts 120/1/60 6710-60 4,868.00 36.375 x 24.5 x 27.25 150 CFM 45 CFM 190 lbs. 18 9,725 BTUH 3,850 Watts 240/1/60 6710-61 6,335.00 44.5 x 33.25 x 32.25 300 CFM 90 CFM 300 lbs. 32.9 19,448 BTUH 6,900 Watts 240/1/60 6710-62 8,825.00

Modular Cleanroom Accessories

Fire Detection AirGard® Duplex Power Outlets System Air Velocity Meter Includes wiring (up to a 30' Senses all hydrocarbon Monitors air velocity run from ceiling junction and non-hydrocarbon to ensure ventilation box) and installation of fires. Its multiple-band efficiency. Mounts on one UL-approved outlet spectrum sensitivity Modular Cleanroom box, in conformance with detects even very small Control Panel for easy NEC specifications. flames. Field of view viewing. High/Low Alarms 110VAC, 50/60Hz Cat. # $/Each (sensor range) is 120° indicate when air speed falls 6704-33 242.00 within 8 feet of fire area. out of range. Cat. # $/Each For specifications and Cat. # $/Each 6704-34 242.00 ordering information, visit TerraUniversal.com. 6704-65 1,247.00 Duplex Power Box Cat. # $/Each Single connection for 6600-27 166.00 Airborne Particle EnviroWatch™ up to five outlets. 20A. Counters Thermo- Sensitivity to 0.1 hygrometer Vacuum/Gas microns. Hand-held Continuous LED display Connections and benchtop models of temperature (°F or °C) Includes installation of vacuum available, many with built- and relative humidity. line and quick connect fitting. in printers. Model shown: Mounted on Terra’s Vacuum (to 29.9"Hg) 6-channel counter with Modular Cleanroom Cat. # $/Each printer (includes case Control Panel for easy 6705-07 309.00 and AC adapter). viewing. Nitrogen/Compressed Cat. # $/Each Air (100 psi) Cat. # $/Each Cat. # $/Each 1510-30 2,737.00 5401-30 203.00 6705-08 309.00

Ultrasonic Sprinkler System This space-saving humidifier fits directly into a standard 2' x 4' Thermally activated, 5mm glass bulb-type sprinkler ceiling grid, eliminating floor clearance requirements. It uses heads are installed at customer-specified locations in five ultrasonic transducers to generate mist and uses the cleanroom ceiling, according to local fire code. only 150W, less power than conventional steam canister Galvanized sprinkler line is cut and threaded for easy . A 45 CFM fan improves humidification on-site installation and connection to water source by efficiency. Requires DI water source. Power: 120VAC a licensed contractor (specify desired line diameter). (220 model also available). Cat. # $/Each Cat. # $/Each Sprinkler Head 6600-90 318.00 6710-29 4,355.00 Cat. # $/linear ft. Sprinkler Line 6600-91 32.00

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 21 Cleanroom Air Conditioning • modular HVAC units ensure comfort and productivity of garbed cleanroom personnel • external air baffles allow quick, easy control over ratio of recirculated/ make-up air • models available with humidity control maintain stable sub-ambient RH levels • All units include Vertical Air Return that directs cooled air to ceiling FFUs via either a ceiling plenum or flexible ducts These modular units remove heat to keep working conditions inside a modular cleanroom cool and dry. Each HVAC unit is mounted to a Vertical Air Return (VAR), which includes a plenum chamber mounted to the side of the cleanroom. This structure (polypropylene or steel, depending on room design) draws air from the cleanroom into the HVAC module and then directs cooled air upward to the cleanroom ceiling, where it enters either a ceiling plenum or duct manifold (see illustrations below). On BioSafe® Cleanrooms, return air is directed to the HVAC unit via ducts inside the BioSafe® panels. An adjustable baffle mounted outside the cleanroom lets you adjust the percentage of fresh make-up air. Stainless Steel BioSafe® Cleanroom with HVAC Module A Terra application engineer will help select the HVAC module(s) appropriate to your No. 6704-32 and stainless steel Vertical Air Return cleanroom, based on room size, number of FFUs, and heat load. Typically, supplemental A/C Modules: Vertical Air Returns are required to recirculate a portion of the cooled cleanroom air Includes air distribution plenum. All models operate on 220VAC, 50/60Hz. through ceiling FFUs. Select FFU Connect Packs to connect return ducts to individual FFUs. Cooling Dimensions AC Control Only AC and RH Control Vertical Air Return (each services up to 3 FFUs) Net BTUH (W" x D" x H") Cat. # $/Each Cat. # $/Each Cat. # $/Each 18,000 33.3 x 17.1 x 70.5 6704-27 3,964.00 – – For Cleanrooms with up to 7' ceilings 6601-10-HC/HE 2,110.00 48,000 42 x 22.5 x 85 6704-28 5,340.00 6704-31 8,344.00 For Cleanrooms with ceilings over 7' 6601-11-HC/HE 2,640.00 57,000 42 x 22.5 x 85 6704-29 7,430.00 6704-32 9,882.00 Larger cleanrooms may require specially permitted, externally installed HVAC UV sterilization available for return ducts—see page 24. units to allow outside discharge of warm air. Call to discuss your application.

HVAC Air Return Configurations

Ceiling A/C with Ductless Ducted Plenum Air Return Applications: Applications: VAR Light Air Conditioning with a Air Conditioning Ceiling Plenum FFU without a Ceiling Light Connect Pack Plenum In very large modular facilities, Terra In these structures, recommends an cooled air is directed insulated ceiling from the HVAC A/C plenum, which module upward provides cooled return Cleanroom with HVAC module, Vertical Air Return through an air return Vertical air to the fan/filter units. and FFU Connect packs module (included with Air Return Filtered Air the A/C unit). This air (VAR) Filtered & Cooled Air Air conditioning return attaches to ductwork that feeds the Fan/Filter Units (FFUs) positioned on modules are mounted Cleanroom with ceiling plenum, the cleanroom ceiling. A single A/C module can typically feed up to six FFUs. HVAC module and Vertical Air Return to air returns, which direct cooled air Additional FFUs are typically fed air recirculated from the cleanroom through upward to the plenum. Depending on the number of fan/filter units (FFUs) Vertical Air Returns, as shown in the illustration above. Depending on the being serviced, additional Vertical Air Return modules may be required to number of fan/filter units (FFUs) being serviced, additional A/C or Vertical ensure ample recirculated air supply to the FFUs. Adjustable baffles on the A/C Air Return modules may be required. Adjustable baffles on the A/C modules modules allow some fresh make-up air to enter the system. allow some fresh make-up air to enter the system. Each FFU requires an FFU Connect pack, which includes flexible ducting and all hardware required to connect and seal the duct. Far left: Vertical Air Return connection to ductwork Near left: FFU connection using No. 6601-00 kit

FFU Connect Packs Includes needed ducting, duct splitters, mounting hardware Cat. # $/Each For Cleanrooms with up to 9' ceilings 6601-00 105.00 For Cleanrooms with ceilings over 9' 6601-01 138.00

22 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com High-Volume Exhaust Fans • Adjustable high-volume fans allows precise regulation of pressure inside a cleanroom or other enclosure • hePA-filtered model removes sub-micron powders and other particles to protect the external environment • Ideal for operations with hazardous materials that require negative pressure inside the controlled environment • Optional power control allows remote adjustment of fan speed to simplify air balancing These high volume exhaust fans convert any enclosure into a negative-pressure room that safely contains biological materials, pharmaceutical powders, and other potential environmental hazards. Negative-pressure containment BioSafe® cleanroom, showing return ducts to ceiling-mounted exhaust fans. Typically, exhaust air from the laminar-flow cleanroom is passed to the exhaust fan by means of take-up ducts located along the room perimeter (see illustration). By adjusting the high-volume fan, you can regulate the amount of air exhausted Air Conditioning Module from and recirculated into the room to control the internal pressure. Recirculated air passes back into the room via a ceiling plenum chamber. Exhaust Fan (floor or ceiling mounted)

A. 3-Phase High-Volume Exhaust Fan This compact unit includes a 2410 RPM fan that provides 1420 CFM of exhaust flow at 0"SP (average velocity: 2,595 feet/minute, exhausted to 10"-dia. duct). Dimensions: 26"W (incl. intake duct) x 23"D x 27"H. Intake flange: 10" dia. Exhaust flange: 7"W x 13"H. Weight: 140 lbs. Optional Variable Control System allow remote fan speed adjustment of multiple units. Cat. # $/Each High-Volume Exhaust Fan (220VAC, 50/60hz, 3 phase) 6602-45-220 2,646.00 Variable Control System 6602-25 Call TUI Allows speed control of multiple units from a remote console

A No. 6602-45: 3-phase model can be remotely controlled B. floor-Mount High-Volume Exhaust Fans These models are ideal for high-volume removal of non-hazardous exhaust. An available filter removes up to 95% of particles 0.5 microns and larger

A. High-Volume Air Handlers (includes 10"– diameter x 2" flange) Corresponding Exit Filters Air Flow Motor 120VAC, 60Hz 220VAC, 50/60Hz 90-95% [email protected]µm Size @ 0" SP @ 1" SP Cat. # $/Each Cat. # $/Each Cat. # $/Each 5340 CFM 4117 CFM 1.5 HP 6710-76 5,987.00 6710-76-220 5,987.00 6710-59 218.00 2418 CFM 2012 CFM 1 HP 6710-67 4,490.00 6710-67-220 4,490.00 6710-64 121.00

B C. hePA-Filtered High-Volume Exhaust Fan Provides up to 3200 CFM (3000 CFM average) exhaust of HEPA-filtered air (99.99% efficient at 0.3 micron particles). It can be used both as an exhaust fan and as a source of clean air to a remote enclosure. Dimensions: 30"W x 48"D x 31"H (67" with built-in stand). Includes stainless steel housing with 16"-diameter inlet/outlet flanges.

Cat. # $/Each 120 VAC 6710-68 6,379.00 208 VAC 6710-68-208 6,218.00 C HEPA Filter (two required) 2100-20 411.00

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 23 Sterilization, Disinfection • UV Radiation • Hydrogen Peroxide Vapor and Decontamination • Antimicrobial Coatings

Terra offers a range of technologies to support your aseptic processes Continuous Treatment Periodic Treatment • UV Sanitizing of return airflow in HVAC ducting and Fan/Filter Units (see • UV Room Sanitizer kills germs on cleanroom walls, ceiling and flooring pg. 22) • VHP (Vaporized Hydrogen Peroxide) sterilizes all surfaces in a room or • Antimicrobial Coatings inhibit growth of bacteria, viruses and mold on enclosure steel surfaces • Topical Sterilization with alcohol or other biocide is effective for localized areas (cleaning kit: No. 5604-65/$208.00) UV Disinfection Solutions Mobile Room Sanitizer UV Ductwork Sanitizers The ultimate solution to eradicate bacteria, viruses and molds! Ideal for installation in HVAC returns, these UV Within 5 minutes, this device provides 99%+ bacterial and modules decrease germ loads on ceiling HEPA filters, viral disinfection of all surfaces within its line of sight, including minimizing contamination of bio-cleanrooms and walls, flooring and ceilings in a laboratory or cleanroom, and contributing to an aseptic processing environment. can be operated for extended periods to kill molds. Portable Available in several configurations for easy and compact for use throughout your facility, it features 360° installation in various duct sizes, their high-intensity IR motion detectors to prevent operation when personnel lamps provide effective “kill rates” of bacteria and are present. Includes four high-output, extended length UVC viruses, even in a fast-moving airflow. Recirculated Teflon-coated lamps and a digital timer/counter for sanitation air becomes increasingly sterile with each pass. Many cycle programming. Treatment area: 12' x 12' x 9'. Certified configurations available; call to discuss a system to UL 867, CSA C2.2#187, FCC CFR 47 Part18, ICES-005. configured to your modular cleanroom. Lamp life: 9,000 hours continuous operation. UV Ductwork Sanitizer, Cat. # $/Each shown with duct cover UV Room Sanitizer 6602-31 14,394.00 removed Replacement Lamp 6602-32 236.00 Eco-Pure™ Chamber Sanitizer Available in several configurations, these economical modules provide fast, effective disinfection of glovebox isolators, pass-through chambers, desiccators and other enclosures. Their versatile mounting system allows easy insertion and removal for convenient sterilization cycles and lamp replacement. Complete ordering information at TerraUniversal.com. See page 22 for FFU sanitation module.

Hydrogen Peroxide Vapor Solutions These systems use hydrogen peroxide vapor (HPV) for fast, effective decontamination of laboratories, cleanrooms, glovebox isolators, and critical environments. HPV is an extremely effective sporicidal agent used against a wide range of biological agents and category III / IV pathogens. The Bioquell BQZ Room Decontamination System services rooms up to 9000 cu. feet. Its parametric cycle control eliminates gas cycle development and pre-conditioning for simple “plug & play” operation. It incorporates a user-friendly touch screen menu and excellent material compatibility, including sensitive electronics. The Bioquell L2 Decontamination System is ideal for rooms and enclosures up to 2600 cu. feet. It provides, fast, validatable decontamination cycles, with up to 6-log sporicidal reduction. Its PLC control system uses a simple menu-driven user interface to set cycle parameters, with added data logging capability. Call to discuss your decontamination application.

24 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Compounding Cleanroom Operation Status Indictor Helps meet USP <797> shows room is operational Requirements! • Complete turnkey clean room meets Class 100 (ISO 5) cleanliness standards for control of submicron particles, ensuring a clean compounding environment • Internal sliding curtain creates a separate gowning ante-room, in accord with USP-797 regulations • Powder-coated steel support frame creates a rigid, durable structure that requires no external bracing or ceiling support • mirror-finish electropolished 304 stainless steel trim is easy to clean • Clear polycarbonate and static-dissipative PVC panels stand up to IPA and other sterilizing agents Terra’s Compounding Clean Rooms provide the ideal environment for compounding sterile injectables and other critical operations.

No. 2900-52A (furnishings optional)

Designed to meet the requirements of USP-797, they include three HEPA filter/fan units that provide a total of 1950 CFM of 99.99% particle-free air (measured at 0.3µm diameter), far exceeding the ISO 7 condition stipulated by USP-797 for compounding clean rooms. In fact, the primary processing area meets ISO 5 (Class 100) cleanliness standards. Select between 6'W x 8'L and 6'W x 10'L floor plans. Both rooms include a sliding clean vinyl curtain that creates a separate antechamber for personnel gowning or product staging. In the typical configuration, the primary compounding room accommodates a 6'-long workbench, which provides ample space for a laminar flow hood, as stipulated by USP<797> requirements (order bench and hood separately). Hardwall designs are available with either rigid polycarbonate or static-dissipative PVC panels. Both offer superior resistance to chemicals, including alcohol and most germicides. By dissipating surface static charges that attract and hold particles, static-dissipative PVC also enhances contamination control. An external swing door is included. All units are 7' high (filter face to floor).

Softwall curtains (included on models below) create a separate ante-chamber.

Gauge: 0 – 0.5" WC Magnehelic® Gauge monitors internal positive pressure; Compounding Clean Rooms an anemometer monitors air movement between main room and antechamber Panel Type* Dimensions (nominal) Cat. # $/Each Filter/Fan Modules (3 total): Full specifications on page 18. Hardwall Polycarbonate 8' x 6' 2900-52A 9,758.00 Filters: 99.99% efficient HEPA filter (rated @ 0.3µm particles) Hardwall Polycarbonate 10' x 6' 2900-53A 10,395.00 Power: 120VAC, 50/60 Hz (220VAC available) Hardwall SDPVC** 8' x 6' 2900-54A 11,551.00 Noise: 54 dBA, measured 30" from filter face @ 90 fpm Hardwall SDPVC** 10' x 6' 2900-55A 12,400.00 Light: 120VAC, 50/60Hz fluorescent, 4-tube fixture; generates 4560 foot Includes (3) filter/fan units, (1) fluorescent light, Magnehelic® gauge, candles internal roller-mount sliding curtain., and external swing door * See descriptions above. Curtain: Cleanroom vinyl curtain mounted on roller assembly; adjustable at any point along the 6' width of the clean room to create desired anteroom size

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 25 Support Services Design • Build • Install • Certify • Equip & Furnish

Terra supports your project from pre-sales consultation to final validation 1. design and Engineering Based on pre-sales consultations, Terra application specialists first recommend environmental control modules for your user requirement specifications, including ISO/Fed Std 209E cleanliness rating, temperature, humidity, static neutralization, sterilization, chemical vapor removal, and hazard containment. Take a Virtual Tour! Using latest-generation design and modeling software, we provide a complete set of drawings for your review and approval. Upon request, Terra also generates 3D animated renderings that allow virtual walk-through of your facility before fabrication begins, one more tool to ensure your design fits your needs. 2. Fabrication Once drawings are approved, Terra performs all fabrication at its Fullerton, CA manufacturing facility, using pre-engineered modular components for optimal speed and efficiency. Finished modular cleanrooms are assembled and tested at Terra before packaging and shipping. 3. Installation Terra technicians perform complete installation at your facility nearly anywhere in the world. Alternatively, we provide advisory technicians who can direct your own team of installers. Complete installation manuals, which include comprehensive pre-installation guidelines to assist in site preparation, in many cases enable you to perform installation yourself. Because Terra modular cleanrooms are freestanding structures that do not need external supports or bracing, they are generally classified as electrical/mechanical equipment and exempted from local permitting requirements. However, codes vary from location to location, and Terra will assist you in meeting local electrical, seismic or fire safety requirements communicated to us when your order is placed. 4. Testing and Air Balancing Terra provides a variety of testing services at our facility. We also arrange for third- party testing and analysis of critical cleanroom performance: • Particle counts (Fed-Std 209D and ISO 14644-1) • Filter leak tests and air change rates (IEST) • Air pressure balancing (FDA cGMP/GGP) • Air Flow Volume (cfm) and speed (ft/min) • Seismic analysis and bracing 5. Certification Upon request, Terra provides third-party certification and agency listings: UL, ETL, CE, CSA Call for a quotation on services tailored to your requirements! Cat. # 3D Modeling/Animation 9999-39 Installation 9998-10 Specify location and labor provided 9999-47 Filter leak test CFM test Cleanroom Performance Specify validation criteria (e.g., FDA cGMP/GGP) Air speed test Particle test Seismic Analysis 6600-98 Air Balancing 9999-48 Based on FFU configuration, pressure requirements ETL/UL/CSA 9999-49 Specify agency listing required CE Mark 9999-50

26 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Cleanroom Step stools and Ladders Step Stools and Step Ladders Models below are electropolished 304 stainless steel and include spring-loaded, non-corroding SS safety casters that retract under load. Perforations limit particle accumulation. 316 SS models available, along with CleanSeam™ versions that feature continuous, sanitary-grade welds to AWS D18.1/D18.2 specification, which create highly cleanable surfaces and eliminate cracks that can harbor contaminants (ordering information at TerraUniversal.com). 304 Stainless Steel Step Stools and Ladders Top Overall No. of Electropolished Platform Dimensions Steps 304 Stainless Steel B No. 2805-51A-2 (W" x D") (W" x D" x H") Cat. # $/Each A 30 x 14 30 x 20 x 24 2 2805-50A-2 1,727.00 B 30 x 12 30 x 28 x 34 3 2805-51A-2 2,171.00 C 30 x 12 30 x 34 x 60 3* 2805-53A-2 2,525.00 D 30 x 12 30 x 36 x 70 4* 2805-52A-2 3,682.00 E 30 x 16 30 x 40 x 80 5* 2805-54A-2 4,490.00 F 30 x 36 30 x 76 x 86 5* 2805-55A-2 4,693.00 G 24 x 48 48 x 63 x 92 5* 2805-57-2 8,520.00 H 15 x 10 18 x 16 x 20 1 2805-80A 836.00 I 15 x 10 18 x 22 x 35 2 2805-81A 1,205.00 J 16 x 10 18 x 25 x 44 3 2805-82A 1,476.00 * Includes safety handrail. A, C, E, H & J not shown. Styles H – J are collapsible, 316 SS Step Stool Covers Step Stool Size W" x D" x H" Cat.# $/Each 30 x 20 x 24 2805-65 87.00 30 x 28 x 34 2805-66 110.00 30 x 24 x 60 2805-67 133.00 F No. 2805-55A-2 30 x 30 x 70 2805-68 151.00 30 x 40 x 80 2805-69 236.00 30 x 76 x 86 2805-70 301.00

No. 2805-57-2: Heavy-duty design supports 500 lbs. on platform

No. 2805-81A Folds for easy storage

I G

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 27 Gowning Room Furnishings

Dual-Sided BioSafe® Cleanroom Mirror (No. 5252-65A – see page 30) Enhances Compliance with Gowning Protocol! • Frameless design and electropolished 304 stainless steel base simplify cleaning, sterilization • Minimizes congestion by providing two viewing surfaces • Easy to position anywhere you need it • Creates natural division between gowning and final check areas of your change room

28 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Garment Cabinets (No. 4101-62A) • Multiple configurations: hanging rods, shelves, or combination rod/shelves • 304 stainless or powder-coated steel • HEPA filter module (optional) maintains vertical flow of particle-free air to prevent dust build-up • Ordering information: page 32

Gowning Benches (See page 30) These ultra-clean electropolished stainless steel benches won’t shed particles or snag wipers during cleaning. Terra offers several designs, including cylindrical-tube models in sizes from 36" to 84" long. Visit TerraUniversal.com for full details.

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 29 Gowning Benches

Terra’s all-electropolished 304 stainless steel gowning benches provide the ideal gowning surface. Their ultra-smooth surfaces won’t shed particles or snag wipers. Choose among four designs; all freestanding models come with durable nylon leveling feet. Perforated top and 316 stainless steel models available at TerraUniversal.com.

Select Models

Bootie Racks (available on free-standing benches with square-tube frames) A Floor-Mounted Solid Top B Free-Standing Solid Top

C Free-Standing Tube Top D Cylinder-Frame/Tube Top E

Floor Mounted (see photo A) Free Standing Design (see photos B, C, D) Bootie Rack** (see photo ) L" x W" x H" A. Solid Top L" x W" x H" B. Solid Top C. Tubular Top D. Cylinder-Frame/ No. of E. Installed Nominal Nominal Tube-Top Slots Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each 36 x 9 x 18 1530-15-2 773.00 36 x 16 x 18 1530-25-2 845.00 1530-10-2 1,367.00 9602-96 1,427.00 12 1560-30-2 665.00 48 x 9 x 18 1530-16-2 838.00 48 x 16 x 18 1530-26-2 931.00 1530-11-2 1,643.00 9602-97 1,633.00 15 1560-31-2 775.00 60 x 9 x 18 1530-17-2 925.00 60 x 16 x 18 1530-27-2 1,089.00 1530-12-2 1,925.00 9602-98 1,884.00 18 1560-32-2 883.00 72 x 9 x 18* 1530-18-2 1,012.00 72 x 16 x 18 1530-28-2 1,162.00 1530-13-2 2,065.00 9602-99 2,145.00 21 1560-33-2 994.00 84 x 9 x 18* 1530-19-2 1,061.00 84 x 16 x 18 1530-29-2 1,181.00 1530-14-2 2,351.00 9600-02 2,343.00 24 1560-34-2 1,104.00 * Includes center leg mount. ** Fits on free-standing benches only (order bench separately). Cleanroom Mirrors—Provide a visual self-check to reinforce gowning protocol Dual-Sided Mirrors (see page 28) This freestanding, frameless mirror includes a solid, electropolished 304 stainless steel base that cushions the dual-sided plate glass in nonoutgassing polyurethane. 35.5"W x 21"D x 73.5"H (35.5"W x 60.5" viewing area). Cat. # $/Each 5252-65A 2,131.00 Wall-Mounted Mirrors Frameless models feature a recessed mounting plate for flush-mounting on the cleanroom wall without rear offset space that can accumulate dust and germs. Caulking creates an easy-clean surface that acts as a germ barrier. Framed models include an ultra-smooth, mirror-finish SS frame with sloping edges to minimize particle build-ups.

Size With Frame Frameless W" x H" Heavy Duty Cat. # $/Each Cat. # $/Each 36 x 72 5252-52A 1,273.00 5252-58A 1,217.00 24 x 36 5252-53 860.00 5252-61A 823.00 18 x 24 5252-54 584.00 5252-60A 558.00 BioSafe® Frameless Cleanroom 24 x 72 5252-55 1,048.00 5252-59A 1,001.00 Wall-mount Mirrors—ideal for aseptic 24 x 48 5252-56 982.00 5252-63A 938.00 No. 5252-52A environments. Shown: No. 5252-60A 18 x 36 5252-57 809.00 5252-62A 774.00

30 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Cleanroom Waste Receptacles and Hampers

All include removable liner

H I J K G

Cleanroom Waste Receptacles Cleanroom Garment Hamper These foot-pedal operated receptacles Polypropylene construction combines are ideal for cleanroom use. Choose cleanliness and chemical resistance, from two easy-to-clean materials: acid- making this hamper suitable for use resistant polypropylene or 304 stainless around a variety of cleanroom and steel (electropolishing available). Both laboratory environments. The recessed models come in many sizes and include foot pedal allows hands-free operation, contoured, tight-fitting lids that ensure and its soft-close mechanism minimizes safe, clean waste disposal. The easy- noise and turbulence when the lip open design and soft-close lid keep drops. Standard design features over operator’s hands free and minimize seven cubic feet of capacity; custom turbulence when the lid closes. The sizes available. rigid liners are treated with an EPA- registered anti-microbial compound and allow easy waste disposal. NOTE: Outside Dimensions: 31"W x 14.5"D x 42"H These receptacles are not intended for Inside Dimensions: 29.5"W x 11.5"D x 35"H containment of radioactive waste. Cat. # $/Each 5151-51A 769.00 New soft-close feature minimizes turbulence when top closes. J Polypropylene

Cleanroom Waste Receptacles Corresponding Rigid Liner Type Capacity Dimensions Ship. Wt. Polypropylene 304 Stainless Steel Electropolished Ship. Wt. (Gallons) W x D x H (in.) (lbs.) 304 Stainless Steel (lbs.) Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each G 3.5 11 dia. x 17 H 9 — — 1456-00 300.00 1456-15A 492.00 3 1456-05 50.00 H 7 12 x 12 x 17 19 1456-25A 605.00 1456-01 473.00 1456-16A 656.00 4 1456-06 53.00 I 12 12 x 12 x 23 24 1456-26A 736.00 1456-02 541.00 1456-17A 964.00 5 1456-07 65.00 J 24 15 x 15 x 30 36 1456-27A 843.00 1456-03 747.00 1456-18A 1,113.00 7 1456-08 77.00 K 40 19 x 19 x 30 48 1456-28A 1,003.00 1456-04 924.00 1456-19A 1,552.00 8 1456-09 94.00 HPC300 3-Channel Particle Counter HPC600 6-Channel Particle Counter Compact size and simple pushbutton controls make Provides the convenience of handheld operation this economical counter ideal for environmental and the printing and remote monitoring capabilities monitoring in tight spaces. Provides three selectable of a benchtop model. Internal memory stores up channels between 0.3µm and 25µm (default: 0.3µm, to 6000 measurements (1000 data sets). Provides 0.5µm and 5.0µm). six selectable channels continuously adjustable Cat. # $/Each in 0.1µm increments between 0.3µm and 25µm HPC300 1510-31 1,911.00 (default: 0.3, 0.5, 0.7, 1.0, 2.0 and 5.0µm). Cat. # $/Each HPC600 1510-30 2,737.00

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 31 Garment and Supplies Cabinets Now in Stainless Steel and Powder-Coated Steel Designs

Type A: Garment storage only. Type B: Garment storage and adjustable shelves (order desired shelf type separately). Type C: Adjustable shelves only (order desired shelf type separately). Type D: Includes two chrome-plated wire shelves adjustable in 1" intervals. All models are fabricated of stainless or cleanroom powder-coated steel. All except type “C” are available with overhead HEPA filter/blower module that showers contents with particle-free air to dislodge and wash away contaminants.

No. 4101-04B with optional A No. 4101-00B with optional hangers B hangers and shelves HEPA-filtered models dislodge and remove particles

C No. 4101-09B with optional shelves D No. 4205-00B, two shelves included

Powder-Coated Steel (see stainless steel models on facing page) Specifications Powder-Coated Steel Cabinets* Corresponding Shelves Type Outside Powder-Coated Steel w/ Powder-Coated Steel w/ Polypropylene Powder-Coated Steel Dimensions Acrylic Doors Dissip. PVC Doors Shelves Shelves (W" x D" x H")

Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each Filter/Blower 36 x 20 x 94 4101-00B 3,225.00 4101-14B 3,891.00 — — — — Cabinet Only 36 x 20 x 78 4101-01B 2,254.00 4101-15B 3,025.00 — — — — A Filter/Blower 36 x 24 x 83 4101-02B 2,875.00 4101-16B 3,648.00 — — — — Steel-reinforced doors Cabinet Only 36 x 24 x 67 4101-03B 2,014.00 4101-17B 2,786.00 — — — — with locks available on Filter/Blower 48 x 20 x 94 4101-04B 3,758.00 4101-18B 4,426.00 4101-30 43.00 4101-40A 81.00 all models—ordering Cabinet Only 48 x 20 x 78 4101-05B 3,448.00 4101-19B 4,115.00 4101-30 43.00 4101-40A 81.00 information at B TerraUniversal.com Filter/Blower 48 x 24 x 83 4101-06B 3,425.00 4101-20B 4,760.00 4101-31 43.00 4101-41A 81.00 Cabinet Only 48 x 24 x 67 4101-07B 2,625.00 4101-21B 3,293.00 4101-31 43.00 4101-41A 81.00 Cabinet Only 30 x 14 x 78 4101-09B 1,720.00 4101-23B 2,320.00 4101-32 62.00 4101-42A 111.00 C Cabinet Only 30 x 18 x 78 4101-11B 1,786.00 4101-25B 2,387.00 4101-33 62.00 4101-43A 111.00 Cabinet Only 36 x 20 x 78 4101-13B 1,920.00 4101-27B 2,519.00 4101-28 62.00 4101-44A 111.00 Filter/Blower 37.75 x 26.5 x 86 4205-00B 3,804.00 4205-02B 4,727.00 Additional Wire Shelves (Type D) D Cabinet Only 37.75 x 26.5 x 72 4205-01B 3,040.00 4205-03B 3,804.00 36"W x 24"D Cat. # 1300-51 $/Each 54.00 * Includes built-in stand with leveling feet. 32 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com More Gowning Area Products — TerraUniversal.com

A./B. ultraClean™ Cylinder Tube Electropolished Cleanroom Hanger Garment Racks Type For Rack E Type Cat. # $/Each Made of high -grade electropolished stainless Closed Loop 1 E C 1530-30-2 14.00 steel, these racks feature sloping 1 /2"-diameter F A, B or C 1530-31-2 14.00 cylindrical tube frames that are easy to wipe F Detachable down. Fixed position design keeps garments firmly G A, B or D 1530-32-2 14.00 Fixed in place. position G style See ordering chart below. Fixed Position D C. ultraClean™ Square Tube Garment Racks These electropolished racks can be disassembled for easy storage and shipping. They are available with one or two hanger rods, in configurations for closed- loop or detachable hangers (photos C and D). A See ordering chart below. D. fixed Position Hanger Rods This style is available with square-tube racks. Slots at 3" increments keep garments from bunching together. Requires fixed-position hangers (photo G). Square-Tube Rack Sliding position style for use with closed-loop or detachable See ordering chart below. Cylinder Frame Rack hangers. 1 (1 ⁄2"-diameter tubes) Overall height: 74" Overall height: 76" For use with detachable hangers. B C Electropolished Stainless Steel Garment Storage Racks Type Dimensions Hanger Capacity A/B. Cylinder Tube Frame C/D. Square Tube Frame See photos (order separately) (order hanger 1530-32-2 separately) above Single Dual A. Single-Rack B. Dual-Rack Single-Rack Dual-Rack Rack Rack Cat. # $/Each Cat. # $/Each Cat. # $/Each Cat. # $/Each C. Sliding Position 48"W x 24"D 15 30 — — — — 9230-00-2 910.00 9230-04-2 1,434.00 (order closed loop 60"W x 24"D 19 38 — — — — 9230-01-2 1,146.00 9230-05-2 1,608.00 or detachable 72"W x 24"D 23 46 — — — — 9230-02-2 989.00 9230-06-2 1,844.00 hangers) 84"W x 24"D 27 54 — — — — 9230-03-2 1,347 .00 9230-07-2 2,067.00 A. B. & D. 48"W x 24"D 15 30 9602-67 1,347.00 9602-75 2,505.00 9230-08-2 1,063.00 9230-12-2 1,948.00 Fixed Position 60"W x 24"D 19 38 9602-68 1,659.00 9602-76 2,929.00 9230-09-2 1,325.00 9230-13-2 2,294.00 (order fixed position 72"W x 24"D 23 46 9602-69 1,805.00 9602-77 3,200.00 9230-10-2 1,440.00 9230-14-2 2,526.00 hangers) 84"W x 24"D 27 54 9602-70 1,975.00 9602-78 3,550.00 9230-11-2 1,569.00 9230-15-2 2,793.00

Stainless Steel Garment & Supplies Cabinets (see powder-coated steel models on facing page)

Specifications Garment Storage Cabinets* Shelves Type Outside Stainless Steel w/Acrylic Stainless Steel w/ Dissip. Stainless Steel Dimensions Doors PVC Doors (W" x D" x H")

Cat. # $/Each Cat. # $/Each Cat. # $/Each Filter/Blower 36 x 20 x 94 4101-57A 7,068.00 4101-68A 7,680.00 — — Cabinet Only 36 x 20 x 78 4101-58A 5,080.00 4101-69A 5,693.00 — — A Filter/Blower 36 x 24 x 83 4101-59A 6,505.00 4101-70A 7,119.00 — — Cabinet Only 36 x 24 x 67 4101-60A 4,531.00 4101-71A 5,142.00 — — Filter/Blower 48 x 20 x 94 4101-61A 8,291.00 4101-72A 8,903.00 4101-83A 245.00 Cabinet Only 48 x 20 x 78 4101-62A 7,579.00 4101-73A 8,189.00 4101-83A 245.00 B Filter/Blower 48 x 24 x 83 4101-63A 6,304.00 4101-74A 8,018.00 4101-84A 245.00 Cabinet Only 48 x 24 x 67 4101-64A 5,693.00 4101-75A 6,304.00 4101-84A 245.00 Cabinet Only 30 x 14 x 78 4101-65A 3,614.00 4101-76A 4,167.00 4101-85A 245.00 C Cabinet Only 30 x 18 x 78 4101-66A 3,770.00 4101-77A 4,320.00 4101-86A 245.00 Cabinet Only 36 x 20 x 78 4101-67A 4,076.00 4101-78A 4,627.00 4101-87A 245.00 ValuLine™ Cleanroom Storage Cabinet Filter/Blower 37.75 x 26.5 x 86 4101-79A 6,768.00 4101-81A 7,445.00 — — Incorporates HEPA fan/filter module. OD: D Cabinet Only 37.75 x 26.5 x 72 4101-80A 5,359.00 4101-82A 5,922.00 — — 50”W x 25”D x 99”H. Other models available. No. 4102-00, $3,304.00 * Height includes built-in stainless steel stand with leveling feet. Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 33 Motorized Shoe Cleaner

Sticky Mats® Peel-off sheets eliminate the need for messy cleaning and make it easy to maintain a clean surface. All below are medium tack; many other styles available. Dimen. Blue (full bottom) Grey (2" bottom) W" x D" Cat. # $/Each Cat. # $/Each 18 x 36 5601-16 47.00 5602-20 45.00 18 x 45 5601-17 57.00 5602-21 50.00 24 x 36 5601-18 62.00 5602-22 64.00 26 x 45 5601-19 78.00 5602-23 76.00 36 x 36 5601-20 95.00 5602-24 91.00 36 x 45 5601-21 116.00 5602-25 113.00 36 x 60 5601-22 166.00 5602-26 173.00 Dimen. White (2" bottom) Corresp. Frames W" x D" Cat. # $/Each Cat. # $/Each Internal vacuum system removes 18 x 36 5602-68 43.00 5602-93 111.00 contaminants on shoes. Five internal 18 x 45 5602-69 50.00 5602-94 131.00 brushes clean deep into seams, welts. 24 x 36 5602-70 64.00 5602-97 143.00 Cat. # $/Each 26 x 45 5602-71 76.00 5602-99 153.00 110VAC, 50/60Hz 1784-14 3,035.00 36 x 36 5602-72 121.00 5603-03 176.00 220VAC, 50Hz 1784-14-220 3,365.00 36 x 45 5602-73 113.00 5603-04 194.00 Exhaust HEPA Filter Kit 1784-13 495.00 36 x 60 5602-74 173.00 5603-05 222.00 (includes filter)

Washing/Drying Station PureDry™ Cleanroom Hand/Glove Dryer Includes an ULPA-filtered, heated overhead dryer and DI-water sink, both activated by an IR “photoeye” Provides warm, contamination-free air for drying hands for clean, no-hands operation. and gloves. Dampened for quiet operation. Brushless Cat. # $/Each DC Motor minimizes particle generation, and ULPA filter One sink model 9600-05 6,251.00 captures microcontaminants. Two sink model 9600-06 12,230.00 Cat. # $/Each Four sink model 9600-07 23,041.00 120VAC/60Hz 3333-33 2,402.00 Six sink model 9600-08 34,854.00 220VAC/50Hz 3333-33-220 2,402.00

34 Items with blue prices usually ship in 5 days. For current lead times: TerraUniversal.com Cleanroom Work Stations Ordering information on next page.

OpenTop™ Perf-Top Bench with Recessed “C”-Base (No. 9601-62)

Perforated-Top Tables • Hidden reinforcements add strength and create superior laminar flow-through (.25" or .75" holes) • Full bull-nosed front edge, in two frame designs

Prices in blue. To Order, Call 714-578-6000 or Fax 714-578-6020 Vol. 5 No.17 35 CHANGE SERVICE REQUESTED PRSRT STD U.S. POSTAGE PAID TERRA UNIVERSAL

Business Without Borders

Items priced in blue usually ship in 5 days. n Order and Quote Carts Online ordering requests for hundreds of stocked items ready for immediate shipping Online quote requests for made-to-order and custom products, n Low-Cost Domestic and International Shipping Competitive quotes include customs brokerage and duties for door-to-door delivery n Hassle-Free Pricing Web prices honored worldwide n International System of Units Web descriptions include SI specifications (metric units of measure) n Comprehensive Product Lines Terra provides single-source convenience at remarkable savings n Online Order Tracking Web-based Real-Time Order Status System lets you monitor progress, from design approval to shop floor to delivery tracking number n Quick-Ship Program Popular models of both Terra-built and distributed products are inventoried for quick shipment – look for blue prices at TerraUniversal.com n Global Network of Sales Representatives Complete listing at TerraUniversal.com