Solutions for earth leakage protection and circuit breakers with automatic reclosing system

Technology for energy efficiency How to enhance electrical quality and continuity for your infrastructures or services by ensuring electrical protection

Nowadays, our industrial production processes Clearly, this is the correct decision. Safety and the myriad of services for individuals normally comes first, even though we cannot leave entail a constant demand for electrical energy. our installations without electric service indefinitely, especially infrastructures, Electrical service continuity ensures high production processes or services with low or energy management efficiency in our zero maintenance. companies and quality of life for individuals in their homes or places of entertainment. These types of applications make it necessary to use intelligent automatic reclosing protection When dealing with electrical protection, one devices. This implies devices that guarantee of the most frequently used solutions for protection that activated only when the problem protection devices is to cut off the electric is real, and that have the capacity to re- supply from affected areas when an insulation establish the electric supply under the reclosing fault is detected. Therefore, we are faced with conditions required by the application, which a critical electric supply continuity point, can be activated or programmed according to given that services and production processes our criteria. are interrupted to protect people against electrocution, or property against fire hazards or other damage. A New Generation Protection systems with automatic reclosing systems Optimisation of sizes Operates perfectly and currents and, with maximum currents, therefore, of the and adapts to the installation's costs ranges of the earth leakage Programmable intelligent protection, display for viewing Earth leakage relays leakage current Ultra-immunized against unwanted tripping Modbus/RS-485 Preventive maintenance Personalised prealarm features for the automatic reclosing External indicator of system, methods the protection and and time sequences reclosing systems status

CIRCUTOR offers awide range of solutions to cater for different types of applications

Protection Reclosing system RCCB reclosing system (In ≤ 63 A)

Programmable earth leakage relay Earth leakage Earth leakage with integrated toroidal + Programmable earth leakage relay + differential transformer + contactor

Programmable earth leakage relay + integrated toroidal + rearmable circuit breaker (In ≤ 80 A) Earth leakage relay + Earth leakage and circuit breaker Earth leakage / circuit breaker * earth leakage transformer + rearmable circuit breaker Programmable earth leakage relay + earth leakage transformer + rearmable circuit breaker

Automatic rearmable circuit breaker (In ≤ 63 A) Circuit breaker Circuit breaker Programmable relay + rearmable circuit breaker

*The different programmable earth leakage relays allows to disable the reclosing system with a circuit breaker Comparison table. Design of models with special features depending on especific Protections with reclosing systems needs, for example: preventive maintenance, control and A complete range of products for earth leakage protection and installation circuit telemanagement of electrical breakers, capable of covering the needs of each installation. installations.

Protection Earth leakage Earth Leakage and/or Circuit breaker Circuit breaker

Reclosing system Earth leakage Earth Leakage and/or Circuit breaker Circuit breaker

Associated circuit breaker for protection Earth leakage Contactor Motorized circuit breaker MT / REC Max MP / MT-FDE purposes

Classification of models based on need, installation and features of the model.

CBS4 / C RA / REC 2 / C RGU-10 / C RAL WRU-10 RAL CBS4 / C RAL RGU-10 / C MT WRU-10 MT WRGU-10MTT RRM REC MAX P

Customer need

Continuity of service █ █ █ █ █ █ █ █ █

Status outputs Only REC2C █ █ █ █ █ █ █

Control, telemanagement, █ █ █ █ █ █ █ █ telecontrol

LCD Display █ █ █ █ █ █

RS-485 communications █ █ █ █

Installation

Single-phase         

Three-phase (4 wires)         

Three-phase       

Used with external earth leakage    WGC

Built-in earth leakage transf 28 Ø 28 Ø 35 Ø

Any, Any, Any, Any, Nominal current ≤63 A ≤80 A ≤80 A ≤63 A ≤63 A Acc. to transf. Acc. to transf. Acc. to transf. Acc. to transf.

Attached to DIN rail       Box  

Size in DIN modules 5 / 7 3 3 3 3 3 1 4.6 / 7.6

Protection features

Type A earth leakage protection TYPE A       (ultra-immunized) (IAW standard)

Used for        instantaneous protection

Use as selective protection      

t A System configurable        in time and current

Pre-alarm output  

Standard IEC 61008-1 IEC 60947-2 Annex M, IEC 62020 IEC 60898

Reclosing system features

Number of reclosing, N 6 3

10, 20, 30, 60, 120 Time between reclosings, T N T 3 minutes and 600 s Programmable

Energy meter 300 s 30 minutes reclosing reset time Earth leakage protection with automatic reclosing system 2/4 poles range, up to 63 A

RCCB self-reclosing

REC2 / REC2C - 2 poles REC2 / REC2C - 4 poles

Opt. Opt. n IΔn Key ln IΔn Key 40 A 30 mA output 40 A 30 mA output x5 63 A 300 mA TEST x7 63 A 300 mA TEST

REC2 is a 2 or 4-pole RCCB associated to a compact mo- LEDs are found on the front panel of the control module, tor and control set that enables the automatic and safe re- they indicate the operational status: closing of the installation, provided that the leakage is not yyManual or automatic reclosing permanent. yyReclosing mode selected yyReclosing status The RCCB is reclosed automatically, in accordance with the yyLock status work mode selected: The REC2C model has an external NC output at the bottom yyTime sequence mode: After a switch trips, REC2 will to indicate when reclosing is not possible: make 6 reclosing attempts, with a timer set at 10, 20, 30, yyTripped unit: status that allows reclosing. 60, 120 and 600 s. If the group can not be reclosed, it yyBlocked by reclosing systems: unit tripped for will be locked in a trip status until it is reset manually. more than 15 minutes. Reclosing not allowed yyUnit without voltage: indicates that the yyInsulation monitoring mode (30 mA): After the tripped unit will not reclose after a trip switch trips, REC2 repeats the previous sequence, but it measures the presence of leakage current There is a sliding window to activate or deactivate the auto- in the installation before rearming the system. matic reclosing of the RCCB.

Applications yyDomestic yySupermarkets yyShops yyRefrigerating chambers yyIndustry yyGreenhouses Earth leakage protection with automatic reclosing system Infrastructures, services, industrial range

Ultra-immunized self-reclosing earth leakage relays

RGU-10 / C RAL WRU-10 CBS-4 / C RA / RAL Toroidal included Ø 28 mm x4

x4 Contactor Contactor Contactor

N T t A Opt. N T t A In N T t A Opt. LCD LCD 6 to LCD DISPLAY RS DISPLAY DISPLAY RS x3 485 x3 80 A x3 485

CBS-4 Toroidal / oval RGU-10

WGC series

Available in: Applications

Ø 25 mm, y Ø 35 mm, yPublic street lighting Ø 55 mm, yyTelecommunications centers Ø 80 mm, yyIn general any infrastructure Ø 115 mm, Ø 140 mm, or service that requires a Ø 180 mm, * constant electric supply 220x105 mm, when maintenance issues 350x150 mm, are complicated or there 500x200 mm. is no easy access. * on request Earth leakage protection and circuit breaker with self-reclosing system Range of services, industrial

Ultra-immunized self-reclosing earth leakage relays

RGU-10 / C MT WRU-10 MT WRGU-10MTT

Toroidal included Ø 28 mm

With the Certificate of: N T t A Opt. N T t A In In t A LCD LCD 6 to 6 to LCD Technical Qualification DISPLAY RS DISPLAY DISPLAY x3 485 x3 80 A 63 A of Telefónica España and Telefónica Móviles España (Spain)

Associated motorized circuit breaker

REC Max MP Series MT Series MT FDE

2 Poles 4 Poles 2 Poles 4 Poles 3 Poles 4 Poles

IΔn IΔn I I I Δn Δn Δn 81 x 130 x 108 x 130 x x2 x2 6 to 6 to 6 to 6 to 80 to outputs inputs 185 mm 185 mm x4.5 63 A x6.5 63 A x5.5 63 A x7.5 63 A 250 A

* Other models from 400 A to 630 A. Applications yyOffices yyShopping malls yyIndustrial farms yyIn general, any process or that service requires a constant electric supply when maintenance issues are complicated or there is no easy access. Circuit Breaker Protection with automatic reclosing system Infrastructures, services, industrial range

Relays with automatic reclosing

REC Max P RRM

2 Poles 4 Poles

In In N T In Opt. 6 to 6 to 6 to RS x4.5 63 A x6.5 63 A x1 250 A 485

Applications yyShopping malls yyOffices yyLivestock operations yyIn general, any process or service that requires a constant electric supply when maintenance issues are complicated or there is no easy access. Application for public lighting

The use of earth leakage protection devices with automatic reclosing was al- ready established in Low Voltage Directive ITC-BT-09, which refers to external lighting installations in the section on protection, measurement and control panels (in Spain). The same section also refers to the trip threshold regulation in relation to the earthing resistance measurement during the commissioning of an electric installation service.

Disconnection threshold of the Ohm Value of the earthing earth leakage protection resistance less than: Ethernet 300 mA 30 Ω

500 mA 5 Ω TCP2RS+ 1 A 1 Ω

RS-485 Our units can be linked to circuit breakers/rearms that are used for the lighting drive system. In turn, these elements are usually governed by timer or photo- electric .

Circuit breaker

Astronomical Clock

Contactor RGU-10 C RAL

CBS-4 C RA CBS-4 C RAL

WGC REC2C WRU-10 WGC WGC WGC WGC Application in industries and offices

The dual function of earth leakage protection devices as automatic reclosing elements enables them to be used in earth leakage protection and circuit breaker applications, given that they can be associated to automatic motor- ised switches. Possible applications of these units in low or zero supervision installations or infrastructures are, among others: yyTelecommunications stations, signalling and control boxes Ethernet yyWater and gas distributors, pumping blocks y yPhotovoltaic installations, panels EDS yyComputer systems, UPS yyFood preservation CBS-4 C RS-485 • Supermarkets, frozen food companies, refrigerating chambers • Hotels, restaurants, catering • Climate controls, heat pumps, air-conditioning yy24-hour services: ATMs, banks, video stores yyExterior building lighting, stores and illuminated indicators yyMunicipal infrastructures, traffic lights, public lighting yyAutomation, home automation, alarms, garage doors, irrigation systems. WGC

Circuit breaker

RGU-10 C

WGC WGC

WGC WGC

Lighting Line Power Line 2

Air-conditioning Line

Power Line 1

MT-FDE MT REC Max MP REC Max P

RGU-10C MT

WGC WGC

WRU-10 MT REC Max P Management and monitoring software

With PowerStudio Scada you can: yyGuarantee the accurate energy supervision of your installation yyAchieve the preventive maintenance of all lines and installations

The RGU-10 C and CBS-4 C (RAL /MT) series use the standardised Modbus/RTU (RS-485) or Modbus/TCP (Ethernet) protocols, which can be queried from any other market application.

http://powerstudio.circutor.com Solutions for earth leakage protection and circuit breakers with automatic reclosing system

+ information: [email protected]

www.circutor.com Designed by: Image and Communications Department - CIRCUTOR, SA

CIRCUTOR, SA - Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 [email protected]

Code: C2P253-01 CIRCUTOR, SA reserves the right to change all information contained in this catalogue.