Product Catalog

Our systems and solutions for photovoltaic power plants

Turnkey systems and solutions for photovoltaic power plants General Terms and Conditions

Dear Customers,

Photovoltaic , once confi ned to space exploration, has since the beginning of the 21st century, gained access to the realm of power generation.

The impressive growth of the PV market, mainly driven during those years by the European interest for this particular technology, has since then led to a major decrease in system prices, bringing PV technology among the emerging technologies for power generation on a large scale.

At Sat Control we are proud to be one of the fi rst companies worldwide to successfully implement innova- tive, cost-effective, reliable, robust and active solar tracking systems in the world.

Sat Control accelerates technological innovations by industry led research and development tracking sys- tems offering outstanding long-term performance. Sat Control provides solutions that demonstrate cost effectiveness, added value, and go beyond the business. Setting the highest quality standards is Sat Con- trol’s main objective.

Sat Control products are a result of intensive research and development efforts, manufactured in a state of the art automated production environment and comply with the principal international standards: Interna- tional Protection Rating (IEC 60529 IP33), Electromagnetic Compatibility (EMC Directive 89/336/EEC) and Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC).

Components and materials used in production originate from well established suppliers, are pre-certifi ed, tested and meet the highest quality standards. Due to the strict quality control at each step of the produc- tion process, Sat Control is able to offer its customers up to 10-year product warranty.

Headquartered in Slovenia, at Sat Control we fi nd our place predominantly in diverse international mar- kets. Tracker installations of every size have been deployed internationally, including utility-scale projects in more than 45 countries over the world including Germany, France, Italy, Slovakia, Czech Republic, Aus- tralia, India, Canada and the United States.

Sat Control’s strategic goal is to become globally innovative and competitive enterprise, providing the most appropriate solar tracking technology for achieving the highest performance and most cost-effective production of solar electricity.

Bogdan Bolka CEO of Sat Control

Table of Contents

1. SOLAR LINEAR TRACKERS 1.a. DUAL AXIS SOLAR TRACKERS 1.a.1. SM44M3V15P ...... page 1-2 1.a.2. SM54M1V6P ...... page 3-6 1.a.3. SM44M1V4P ...... page 7-10 1.a.4. SM44M1V3P ...... page 11-14 1.a.5. SM44M1V2P ...... page 15-18 1.a.6. Iron-Reinforcement Cage ...... page 19-20

1.b. SINGLE AXIS SOLAR TRACKERS 1.b.1. SM40M1V4P ...... page 21-24 1.b.2. SM40M1V3P ...... page 25-28 1.b.3. SM40M1V2P ...... page 29-32 1.b.4. SM3SPMOG+ ...... page 33-36

2. SOLAR PANELS 2.a.1. PV panel polycrystalline JC250M-24/Bb ...... page 37-38 2.a.2. PV panel polycrystalline JC300M-24/Ab ...... page 39-40 2.a.3. PV panel monocrystalline JC250S-24/Bb ...... page 41-42 2.a.4. PV panel polycrystalline JC200S-24/Db ...... page 43-44 2.a.5. PV panel HJM195M-24 ...... page 45-46 2.a.6. PV panel HJM250M-32 ...... page 47-48 2.a.7. PV panel HJM180D-36 ...... page 49-50

3. SOAR 3.a. SM44M1HEL3M ...... page 51-52 3.b. SM44M1HEL6M ...... page 53-54 3.c. SM44M3HEL25M ...... page 55-56

4. SOLAR LINEAR MOTORS ACTUATORS 4.a. Motor SM4S520M1 ...... page 57-58 4.b. Motor SM4S900M3C3 - with Clamp C3 ...... page 59-60 4.c. Motor SM4S900M3C4 - with Clamp C4 ...... page 61-62 4.d. Motor SM4S900M3NC - without Clamp ...... page 63-64

5. SOLAR POSITIONERS

5.a. SOLAR POSITIONER 2-AXIS MODULE NANO ...... page 65-66 5.b. SOLAR POSITIONER 2-AXIS MODULE MICRO ...... page 67-68 5.c. SIGMA SOLAR SERVER ...... page 69-70 5.d.1. SMPS Power supply TDK - Lambda DPP 50-24 ...... page 71-71 5.d.2. SMPS Power supply TDK - Lambda DPP 100-24 ...... page 71-71 5.d.3. SMPS Power supply TDK - Lambda DPP 480-24-3 ...... page 72-72 5.e. Junction Box (j-box) Set & 5.f. Connection Board Sestiv 39B ...... page 73-74 5.g. USB 2.0 to RS485 Mini Adapter with Terminal Block ...... page 75-75 5.h. Cable USB 2.0 - USB-A -› Micro-B ...... page 76-76 5.i. Wind sensor WS XS Vestmatic ...... page 77-77 5.j. Plastic mounting bracket for wind sensor ...... page 78-78

6. GROUND SCREWS 6.a. GROUND SCREW ...... page 79-81 6.b. SET GROUND SCREWS ...... page 82-84

7. MONITORING SYSTEM 7.a. HELIOS ANALYTICS ...... page 85-86

8. SAT CONTROL WEBSHOP 8.a. SAT CONTROL WEBSHOP ...... page 87-88

1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.1. SM44M3V15P

Product code: SM44M3V15P

Dual-Axis SM44M3V15P

Dual-Axis Solar Tracker SM44M3V15P with accuracy better than 0,5 deg and backstructure for 15 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 25 m2 surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual axis motor you can get 7% more income of energy compared to Single axis motor.

1 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚

Type of hour-angle engine Linear Motor SM4S900M3 with stroke of 900 mm

Type of elevation shaft and stroke Linear motor SM4S900M3 with stroke of 900mm

Hour-angle shaft diameter and length Square tube 200x200 mm, L=2280 mm (steel)

Turning speed of hour angle shaft /

Turning speed of elevation shaft /

Max. dynamic torque of the hour-angle shaft /

Max. dynamic torque of elevation shaft /

Destructive torque of the hour-angle shaft /

Destructive torque of elevation shaft /

Backstructure size 5 x 5 m (H size 4 x 2,45 m)

Type of backstructure clamp Toothed scissors gripers - 60 pcs

Tube diameter for mounting Square tube 200x200 mm, H=3500 mm (steel)

Max. dimensions of a solar panel 15 pieces of 0.99 m x 1.67 m in total 25 m2

Max. weight of a solar panel 15 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval 1 minute (0.25°)

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ±15% 4A(5A current capacity)

Backup battery CR 2512 coin

Turning time interval 1 minute (0.25°)

Max. Current of elevation shaft /

Standby consumption (when is not moving) 60mA @ 24 VDC

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1.5mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130km/h (in vertical position) up to 180km/h (in horizontal position)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 5000 (L) x 800 (W) x 800 (H) mm (Wooden Box is not icluded with kit)

Product weight 750kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included usage Yes, for additional payment 2 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.2. SM54M1V6P

Product code: SM54M1V6P

Dual Axis Solar Tracker SM54M1V6P

Dual-Axis Solar Tracker SM54M1V6P with accuracy better than 0,5 deg and backstructure for 6 pieces of solar panels dimensions 0,808 m x 1,580 m and weight of 25 kg max each. So together for 7,65 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at small and large plants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 130km/h. In a Year basis with 2 axis motor you can get 7% more income of energy compared to single axis motor. Solar tracker anti-shadowing software func- tion included. 3 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities

Number of turning axis Dual-Axis, Azimuth-Elevation System

Azimuth Angle Limit 270˚

Elevation angle 90˚

Type of Azimuth-angle engine Slew drive SM5M1

Type of elevation shaft and stroke Linear motor SM4S520M1

Azimuth-angle shaft diameter and length /

Turning speed of Azimuth angle shaft 0,9˚/s

Turning speed of elevation shaft 0,052 - 0,062 °/s at no load

Max. dynamic torque of the Azimuth-angle shaft Azimuth 150 Nm

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA

Destructive torque of the Azimuth-angle shaft 1500 Nm

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA

Backstructure size 2,424 m x 3,160 m

Type of backstructure clamp Toothed gripers - 24 pcs

Tube diameter for mounting Ø133 x 3 mm

Max. dimensions of a solar panel Array of 6 pieces of 0,808 m x 1,580 m in total 7,65 m2

Max. weight of a solar panel 6 pcs per 25 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Communication Data

Type of communication interface RS485

Networking solution for control from centre RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery /

Turning time interval 5 sec - 15 minute, but controlled via Sigma Solar Server Web based

Max. consumption during the operation of the Azimuth-angle shaft 500 mA @ 150 Nm

Max. Current of elevation shaft 500 mA @ 400Nm

Standby consumption (when is not moving) 25 mA ± 25% @ 24V

Power supply connection 1 cable of 2 wires with an Internal Cu Conductor of 1,0 mm2 for power and 1 twisted pair 0,25mm2 (2 wires) (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Neutral Salt Spray (3000 h, EN ISO 9227 NSS) /

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product /

Product weight 155kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, but controlled via Sigma Solar Server Web based Heliostat usage Yes, but controlled via Sigma Solar Server Web based 4 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.2. SM54M1V6P

5 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.2. SM54M1V6P

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real and conversed electrical power was measured.

Test conditions: Solar panels (both): 1.17 kWp (producer spec. at AM 1.5) Date: May 2011 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 4890.6Wh Average energy of motorized: 7920.9Wh

Note: Sum of motor energy consumption through all day is 35.5Wh or 0.22% of all collected energy.

6 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.3. SM44M1V4P

Product code: SM44M1V4P

Dual Axis Solar Tracker SM44M1V4P

Dual Axis Solar Tracker SM44M1V4P with accuracy better than 0,5 deg and backstructure for 4 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 7,7 m2 solar panel sur- face. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with 2 axis motor you can get 7% more income of energy compared to single axis motor. Solar tracker anti-shadowing software function included. 7 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Turning speed of elevation shaft 0,052 - 0,062 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 Nm - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 4000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 16 pcs

Tube diameter for mounting Ø76,1 x 3,6 mm with reduced tube to Ø68 mm (not included with kit)

Max. dimensions of a solar panel 4 pieces of 0,99 m x 1,95 m in total 7,7 m2

Max. weight of a solar panel 4 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm & 1 box of 2050 (L) x 180 (W) x 70 (H) mm

Product weight 55 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included Heliostat usage Yes, for additional payment 8 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.3. SM44M1V4P

Legend:

Legend:

Legend:

9 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.3. SM44M1V4P

2 Real energy measurement of two equal solar panels (fixed and motorized)

Legend: Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot- Legend:

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 1.2 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

10 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.4. SM44M1V3P

Product code: SM44M1V3P

Dual-Axis Solar Tracker SM44M1V3P

Dual-Axis Solar Tracker SM44M1V3P with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic sig- nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual Axis motor you can get 7% more income of energy compared to Single Axis motor. 11 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Turning speed of elevation shaft 0,052 - 0,062 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 Nm - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 3000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 12 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel 3 pieces of 0,99 m x 1,95 m in total 5,8 m2

Max. weight of a solar panel 3 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 45 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes 12 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.4. SM44M1V3P

Legend:

Legend:

Legend:

13 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.4. SM44M1V3P

2 Real energy measurement of two equal solar panels (fixed and motorized)

Legend: Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats. Usage at homes: on-grid at roof on houses, trafic signalisations,Legend: street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

14 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.5. SM44M1V2P

Product code: SM44M1V2P

Dual-Axis Solar Tracker SM44M1V2P

Dual-Axis Solar Tracker SM44M1V2P with accuracy better than 0,5 deg and backstructure for 2 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 4,0 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic sig- nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a Year basis with Dual Axis motor you can get 7% more income of energy compared to Single Axis motor. 15 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Turning speed of elevation shaft 0,052 - 0,062 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 Nm - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 2000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 8 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel 2 pieces of 0,99 m x 1,95 m in total 3,9 m2

Max. weight of a solar panel 2 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 35 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included Heliostat usage Yes, for additional payment 16 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.5. SM44M1V2P

Legend:

Legend:

Legend:

17 1. SOLAR TRACKERS - 1.a. DUAL AXIS SOLAR TRACKERS

1.a.5. SM44M1V2P

2 Real energy measurement of two equal solar panels (fixed and motorized)

Legend: Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats. Usage at homes: on-grid at roof on houses, trafic signalisations,Legend: street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 0.6 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 2508,0Wh Average energy of motorized: 4062,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.43% of all collected energy.

18 1. IRON - REINFORCEMENT CAGE

1.a.6. Iron-reinforcement cage JEKABBSM44M3V15P

Product code: JEKABBSM44M3V15P

Iron-reinforcement cage for Overground Concrete Foundation for Solar Tracker SM40M3V15P

The foundation of the solar power system can take various forms. Consequently, optimum consideration can be given to the local conditions.

The rectangular overground foundation is generally used if a stony or rocky substrate precludes an under- ground variant of the foundation structure.

19 1. IRON - REINFORCEMENT CAGE

Technical Capabilities 1.a.6. Iron-reinforcement cage JEKABBSM44M3V15P

20 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.1. SM40M1V4P

Product code: SM40M1V4P

Single-Axis Solar Tracker SM40M1V4P

Single-Axis Solar Tracker SM40M1V4P with accuracy better than 0,5 deg and backstructure for 4 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 7,7 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, heliostats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. In a year basis with Dual Axis motor you can get 7% more income of energy compared to Single Ais motor. 21 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities

Number of turning axis Single-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the le shaft 200 - 330 Nm depend from HA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 4000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 16 pcs

Tube diameter for mounting Ø76,1 x 3,6 mm with reduced tube to Ø68 mm (not included with kit)

Max. dimensions of a solar panel 4 pieces of 0,99 m x 1,95 m in total 7,7 m2

Max. weight of a solar panel 4 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm & 1 box of 2050 (L) x 180 (W) x 70 (H) mm

Product weight 52 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included Heliostat usage No 22 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.1. SM40M1V4P

Legend:

Legend:

Legend:

23 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.1. SM40M1V4P

2 Real energy measurement of two equal solar panels (fixed and motorized)

Legend: Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats. Usage at homes: on-grid at roof on houses, trafic signalisations,Legend: street light, cot-

Real energy measurement of two equal solar panels (fixed and motorized)

Two equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 1.2 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

24 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.2. SM40M1V3P

Product code: SM40M1V3P

Single-Axis Solar Tracker SM40M1V3P

Single-Axis Solar Tracker SM40M1V3P with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. 25 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities

Number of turning axis Single-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 3000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 12 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel 3 pieces of 0,99 m x 1,95 m in total 5,8 m2

Max. weight of a solar panel 3 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2,5A current capacity)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 41 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included Heliostat usage No 26 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.2. SM40M1V3P

Legend:

Legend:

Legend:

27 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.2. SM40M1V3P

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results:

Average energy of fixed: 3762,0Wh Legend: Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats.Real energy Usage measurement at homes: of on-grid two equal at solar roof panels on houses, (fixed andtrafic motorized) signalisations, street light, cot-

Three equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.29% of all collected energy.

28 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.3. SM40M1V2P

Product code: SM40M1V2P

Single-Axis Solar Tracker SM40M1V2P

Single-Axis Solar Tracker SM40M1V2P with accuracy better than 0,5 deg and backstructure for 2 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So together for 4,0 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV. Usage at homes: on-grid at roof on houses, trafic sig- nalisations, street light, cottages, small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h. 29 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities

Number of turning axis Single-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Backstructure size 2 pcs of 1000 (H) mm & 2 pcs of 2000 (V) mm

Type of backstructure clamp Toothed scissors gripers - 8 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a solar panel 2 pieces of 0,99 m x 1,95 m in total 3,9 m2

Max. weight of a solar panel 2 pcs per 30 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ ***)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval Tipicaly 6 - 7 s

Communication Data

Type of communication interface USB interface

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery Backup for timer, position and data

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Box 190 (L) x 140 (W) x 70 (H) mm with connection harness

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 35 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included Heliostat usage No 30 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.3. SM40M1V2P

Legend:

Legend:

Legend:

31 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.3. SM40M1V2P

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Legend: Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats.Real energy Usage measurement at homes: of on-grid two equal at solar roof panels on houses, (fixed andtrafic motorized) signalisations, street light, cot-

Three equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 0.6 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 2508,0Wh Average energy of motorized: 4062,0Wh

Note: Sum of motor energy consumption through all day is 17.52Wh or 0.43% of all collected energy.

32 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.4. SM3SPMOG+

Product code: SM3SPMOG+

Solar Tracker SM3SPMOG+

Single-Axis Solar Tracker SM3SPMOG+ made to be supplied with power from 12 to 69 VDC from external power supply. Without charger controller. Suitable for panels on grid Up to dimensions 2m x 1m usage at homes on-grid at roof on houses, for trafic signalisation, for street light use, for power suplly at cottages, for small and large powerplants where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Minimal wind resistance is 180km/h is required and price is imporant too. All metal gear parts inside ensure high destruction forces.

33 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

Technical Capabilities Mechanical Capabilities

Number of turning axis Single-Axis

Hour Angle Limit 96˚ typical / 100˚ max., software and hardware limit

Elevation angle 75° manual fixation

Type of hour-angle engine Servo motor with position encoder on cogwheel

Hour-angle shaft diameter and length Ø40 mm, L=1150 mm (steel)

Turning speed of hour angle shaft 0,5°/s ± 25% @ 24V at no load

Max. dynamic torque of the hour-angle shaft 65 Nm

Destructive torque of the hour-angle shaft >200 Nm

Backstructure size 2 pcs of 1000 (H) mm

Type of backstructure clamp Toothed scissors gripers - 4 pcs

Tube diameter for mounting Ø50,0 - 60,0 mm

Max. dimensions of a solar panel 1 piece of 2,0 m x 1,0 m in total 2,0 m2

Max. weight of a solar panel 1 pc per 25 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,5˚ (optionally <0,1˚ - for additional payment)

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of Positioning System Servo driver positioner with TdAPS arc logic function calc.

Type of Positioner Solar Positioner SP27C

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via web site

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Turning time interval 1 minute (0,25°)

Communication Data

Type of communication interface USB interface since beginning of the January 2010, before RS232

Networking solution for control from centre CAN BUS, RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply Recommended 24 VDC (working from 12 to 69 VDC), (2,5 A current capacity @ 12V)

Backup battery CR 2512 coin

Max. consumption during the operation of the hour-angle shaft 500 mA @ 65 Nm

Standby consumption (when is not moving) 35 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Packaging

Dimensions of a packed product 1 box of 1175 (L) x 135 (W) x 200 (H) mm

Product weight 9 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function Yes, included Heliostat usage No 34 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.4. SM3SPMOG+

● G.L. and +15˚ or -15˚ according to the season

● SET TO THE CALCULATED ANGLE ● FOR EXAMPLE: 45˚

35 1. SOLAR TRACKERS - 1.b. SINGLE AXIS SOLAR TRACKERS

1.b.4. SM3SPMOG+

2 Real energy measurement of two equal solar panels (fixed and motorized)

Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Legend: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats.Real energy Usage measurement at homes: of on-grid two equal at solar roof panels on houses, (fixed andtrafic motorized) signalisations, street light, cot-

Three equal solar panels were exposed to the real sun and conversed electrical power was measured.

Test conditions: Solar panels (both): 200W (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear

Results: Average energy of fixed: 836,8Wh Average energy of motorized: 1354,0Wh

Note: Sum of motor energy consumption through all day is 20Wh or 1.45% of all collected energy.

36 2. SOLAR PANELS

2.a.1. PV panel polycrystalline JC250M-24/Bb, 40mm frame

Product code: PVPJC250M24BB

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

5% % 100% 7. .5 9 97 95% Linear Add Performance ed Va Warranty 90% lue

85% Traditional

% Warranty .0 80% 80 Performance Figures in % Performance Figures 0% 0 1 5 10 15 20 25 YEAR

PV panel polycrystalline JC250M-24/Bb

Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and stand- alone systems. The modules characterized by outstanding longterm performance are designed to withstand rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate is granted.

37 2. SOLAR PANELS

• Dimensions • Curves

992mm 40mm 947mm 1 0

2 4-7.5X7.5 1 000W/m JUNCTION BOX DRAIN HOLE 8 2 LABLE 800W/m

) 6 (A 600W/m2 nt re r

Cu 4 2 400W/m 1000mm m m m

2 2 200W/m 860m 1360m 1640m 2- 4 GROUNDING HOLE 0 0 5 1 0 1 5 20 25 30 35 40 8- 9X5 Voltage (V) INSTALLING HOLE

16-8X3.5 DRAIN HOLE Varied Irradiation Efficiencies Irradiance 200W/m 2 400W/m 2 600W/m 2 800W/m 2 1000W/m 2

Efficiency 15.5% 15.9% 15.9% 15.8% 15.7%

JC250M-24/Bb JC255M-24/Bb 250 W 255 W 0 ~ +5W 0 ~ +5W 15.4% 15.7% 8.31 A 8.39 A 30.1 V 30.4 V 8.83 A 8.86 A 37.4 V 37.5 V

Electrical Characteristics NOCT JC250M-24/Bb JC255M-24/Bb Maximum Power (Pmax) 185 W 189 W Maximum Power Current (lmp) 6.57 A 6.63 A Maximum Power Voltage (Vmp) 28.2 V 28.5 V

Short Circuit Current (lsc) 7.12 A 7.20 A Open Circuit Voltage (Voc) 35.0 V 35.1 V Values at Normal Operating Cell Temperature, Irradiance of 800 W/m2 , spectrum AM 1.5, ambient temperature 20oC, wind speed 1 m/s

Mechanical Characteristics Characteristics Cell Type 156 x156 mm Polycrystalline, 60 (6x10) pcs in series Temperature Coefficient of Voc Glass High Transmission, Low lron, Tempered Glass Temperature Coefficient of Isc Frame Anodized Aluminum Alloy Temperature Coefficient of Pmax Junction Box IP65/IP67 rated, with bypass diodes Nominal Operating Cell Temperature (NOCT) Dimension *1640 x 992 x 40 mm Output Cable 4 mm2 (EU)/12 AWG (US), 1000 mm Weight 19 Kg Installation Hole Location See Drawing Above

Packing Information Maximum Ratings Container 20’ GP 40’ GP 40’ HQ Operating Temperature Pallets per Container 12 28 28 Maximum System Voltage Pieces per Container 300 700 770 Maximum Series Fuse Rating

38 2. SOLAR PANELS

2.a.2. PV panel polycrystalline JC300M-24/Ab, 40mm frame

Product code: PVPJC300M24AB

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

% % 100% .5 .5 97 97

95% Linear Add Performance ed Va Warranty 90% lue

85% Traditional

% Warranty .0 80% 80 Performance Figures in % Performance Figures 0% 0 1 5 10 15 20 25 YEAR

PV panel polycrystalline JC300M-24/Ab

Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and stand- alone systems. The modules characterized by outstanding longterm performance are designed to withstand rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate is granted.

39 2. SOLAR PANELS

• Dimensions • Curves

992mm 947mm

1 0

4-7.5X7.5 JUNCTION BOX DRAIN HOLE 8

LABLE

) 6 (A nt m re r 4 Cu 1000m m m m 2 1176m 1676m

1956m 2- 4 GROUNDING HOLE 0 0 1 0 20 30 40 50

8- 9X5 Voltage (V) INSTALLING HOLE

16-8X3.5 DRAIN HOLE Varied Irradiation Efficiencies Irradiance 200W/m 2 400W/m 2 600W/m 2 800W/m 2 1000W/m 2

Efficiency 15.1% 15.5% 15.6% 15.6% 15.5%

JC295M-24/Ab JC300M-24/Ab 295 W 300 W 0 ~ +5W 0 ~ +5W 15.2% 15.5% 8.13 A 8.20 A 36.3 V 36.6 V 8.62 A 8.69 A 44.7 V 44.8 V

JC295M-24/Ab JC300M-24/Ab 219 W 222 W 6.57 A 6.67 A 33.3 V 33.4 V 6.96 A 7.02 A 41.8 V 41.9 V

Mechanical Characteristics Characteristics Cell Type 156 x156 mm Polycrystalline, 72 (6x12) pcs in series Temperature Coefficient of Voc Glass High Transmission, Low lron, Tempered Glass Temperature Coefficient of Isc Frame Anodized Aluminum Alloy Temperature Coefficient of Pmax Junction Box IP65/IP67 rated, with bypass diodes Nominal Operating Cell Temperature (NOCT) Dimension *1956 x 992 x 50 mm Output Cable 4 mm2 (EU)/12 AWG (US), 1000 mm

Weight 29 Kg Installation Hole Location See Drawing Above

Packing Information Maximum Ratings Container 20’ GP 40’ GP 40’ HQ Operating Temperature Pallets per Container 10 24 24 Maximum System Voltage Pieces per Container 200 480 528 Maximum Series Fuse Rating

40 2. SOLAR PANELS

2.a.3. PV panel monocrystalline JC250S-24/Bb, 40mm frame

Product code: PVPJC250S24BB

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

% % 100% .5 .5 96 96

95% Linear Add Performance ed Va Warranty 90% lue

85% Traditional

% Warranty .0 80% 80 Performance Figures in % Performance Figures 0% 0 1 5 10 15 20 25 YEAR

PV panel monocrystalline JC250S-24/Bb

Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and stand- alone systems. The modules characterized by outstanding longterm performance are designed to withstand rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate is granted.

41 2. SOLAR PANELS

• Dimensions • Curves

992mm 40mm 947mm

10 1000W/m˛ 4-7.5X7.5 JUNCTION BOX DRAIN HOLE 8 800W/m˛ LABLE

) 6 600W/m˛ (A nt re r 4 400W/m˛ Cu 1000mm m m 200W/m˛ m 2 860m 1360m 2- 4 1640m GROUNDING HOLE 0 0 5 1 0 1 5 20 25 30 35 40

8- 9X5 Voltage (V) INSTALLING HOLE

16-8X3.5 DRAIN HOLE Varied Irradiation Efficiencies Irradiance 200W/m 2 400W/m 2 600W/m 2 800W/m 2 1000W/m 2

Efficiency 15.9% 16.2% 16.2% 16.1% 16.0%

JC250S-24/Bb JC255S-24/Bb JC260S-24/Bb 250 W 255 W 260 W 0 ~ +5W 0 ~ +5W 0 ~ +5W 15.4% 15.7% 16.0% 8.32 A 8.44 A 8.55 A 30.1 V 30.2 V 30.4 V 8.87 A 8.99 A 9.10 A 37.5 V 37.6 V 37.7 V

JC250S-24/Bb JC255S-24/Bb JC260S-24/Bb 184 W 188 W 191 W 6.57 A 6.62 A 6.66 A 28.0 V 28.4 V 28.7 V 7.15 A 7.21 A 7.28 A 35.1 V 35.2 V 35.3 V

Mechanical Characteristics Characteristics Cell Type 156 x156 mm Monocrystalline, 60 (6x10) pcs in series Temperature Coefficient of Voc Glass High Transmission, Low lron, Tempered Glass Temperature Coefficient of Isc Frame Anodized Aluminum Alloy Temperature Coefficient of Pmax Junction Box IP65/IP67 rated, with bypass diodes Nominal Operating Cell Temperature (NOCT) Dimension *1640 x 992 x 40 mm Output Cable 4 mm2 (EU)/12 AWG (US), 1000 mm

Weight 19 Kg Installation Hole Location See Drawing Above

Packing Information Maximum Ratings Container 20’ GP 40’ GP 40’ HQ Operating Temperature Pallets per Container 12 28 28 Maximum System Voltage Pieces per Container 300 700 770 Maximum Series Fuse Rating

42 2. SOLAR PANELS

2.a.4. PV panel monocrystalline JC200S-24/Db, 35mm frame

Product code: PVPJC200S24DB

High Module Conversion Efficiencies

Easy Installation and Handling

Mechanical Load Capability of up to 5400 Pa

Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards

ISO9001, OHSAS18001, ISO14001 Certified

% % 100% .5 .5 96 96

95% Linear A Performance dde 90% d Va Warranty lue 85% Traditional

% Warranty .0 80% 80 Performance Figures in % Performance Figures 0% 0 1 5 10 15 20 25 YEAR

PV panel monocrystalline JC200S-24/Db

Sat control offers high-power, high-quality, and highly efficient PV modules ideal for gridconnected and stand- alone systems. The modules characterized by outstanding longterm performance are designed to withstand rigorous operating conditions using proven and highest quality certified materials. IEC 61215 Ed.2 certificate is granted.

43 2. SOLAR PANELS

• Dimensions • Curves

808mm 35mm

6 1000W/m˛

5 800W/m˛

) 4

(A 600W/m˛ nt

re 3 r

Cu 400W/m˛ 2

m 200W/m˛ 1 1580m 0 0 10 20 30 40 50

Voltage (V) Varied Irradiation Efficiencies

Irradiance 200W/m 2 400W/m 2 600W/m 2 800W/m 2 1000W/m 2

Efficiency 15.4% 15.8% 15.8% 15.8% 15.7%

JC190S-24/Db JC195S-24/Db JC200S-24/Db 190 W 195 W 200 W 0 ~ +5W 0 ~ +5W 0 ~ +5W 14.9% 15.3% 15.7% 5.19 A 5.32 A 5.41 A 36.6 V 36.7 V 37.1 V 5.49 A 5.61 A 5.70 A 44.9 V 45.0 V 45.3 V

JC190S-24/Db JC195S-24/Db JC200S-24/Db 140 W 144 W 147 W 4.13 A 4.22 A 4.27 A 34.0 V 34.2 V 34.5 V 4.42 A 4.52 A 4.60 A 42.1 V 42.3 V 42.4 V

Mechanical Characteristics Characteristics Cell Type 125 x125 mm Monocrystalline, 72 (6x12) pcs in series Temperature Coefficient of Voc Glass High Transmission, Low lron, Tempered Glass Temperature Coefficient of Isc Frame Anodized Aluminum Alloy Temperature Coefficient of Pmax Junction Box IP65/IP67 rated, with bypass diodes Nominal Operating Cell Temperature (NOCT) Dimension *1580 x 808 x 35 mm Output Cable 4 mm2 (EU)/12 AWG (US), 1000 mm

Weight 16 Kg Installation Hole Location See Drawing Above

Packing Information Maximum Ratings Container 20’ GP 40’ GP 40’ HQ Operating Temperature Pallets per Container 12 28 28 Maximum System Voltage

Pieces per Container 372 868 952 Maximum Series Fuse Rating

44 2. SOLAR PANELS

2.a.5. Photovoltaic solar panel HJM195M-24

Product code: PVSPHJM195M24

808 (31.8) 762 (30.0) 35 (1.38) 35 (1.38) 80 (3.15) 80

Junction box 4-6*6 (IP65) Waterspout Bar code 90 (3.54) 8-14*9 Mounting slots Lable 130 (5.12) 130 800 (31.5) 800 1580 (62.2) 1580 1300 (51.2) 1300 2- 4 Ground hole

Cable Cable

900mm 900mm

16-3.5*8 Waterspout

9 (0.35) 70 (2.76) 70 (2.76)

PV panel monocrystalline HJM195M-24

The HJM195D-24, HJSOLAR Solar’s 195 watt photovoltaic module features 17-18% encapsulated cell efficien- cy and 15.2% module efficiency. With a 25 year warranty, the HJM195D-24 has superb durability to withstand rigorous operating conditions. Ideal for grid-connected and remote power systems, the HJM185D-36 modules offer the maximum usable power per square foot of solar array.

45 2. SOLAR PANELS

Electrical Characteristics Model type HJM190M-24 HJM195M-24 HJM200M-24 Peak power (Pmax) 190W 195W 200W Cell type Mono , 125mm x 125mm Maximum power voltage (Vmp) 36.71 37.59 37.87 Maximum power current (Imp) 5.16 5.20 5.29 Open circuit voltage (Voc) 44.06 44.46 44.86 Short circuit current (Isc) 5.57 5.62 5.71 Maximum system voltage TUV DC 1000V/UL DC600V Temp. Coeff. of Isc (TK Isc) Temp. 0.037 %/ °C Coeff. of Voc (TK Voc) Temp. - 0.34 %/ °C Coeff. of Pmax (TK Pmax) - 0.37 %/ °C Normal operating cell temperature 45 ± 2 °C Power tolerance ±3 % Standard test conditions (STC) AM1.5, 1000W/m2, Module Temperature 25 °C

Mechanical Characteristics Dimension (mm) 1580 x 808 x 35 Weight (kg) 16.5

72 cells (125 mm x 125 mm) configured geometrically Solar cells for a 6 x 12 matrix connected in series

Output cable length (mm) 900

Front: High transmission 3.2 mm tempered glass. Construction Rear: White backsheet; Encapsulant: EVA.

Features Current-Voltage & Power-Voltage Curve

• High module conversion efficiency up to 15.7%. 6.0 240 • 25-year limited warranty on power output: • 90% power output over 12 years 5.0 200 • 80% power output over 25 years • Free from defects in materials and workmanship for 5 years 4.0 160 • Bypass diode minimizes the power drop caused by shade. ) ) • Tempered glass, EVA resin, and weatherproof film, and 3.0 120 anodized aluminum frame for extended outdoor use. Power (W • TUV UL Listings: UL 1703, IEC61215, IEC61730. Current (A 2.0 80 Packing Configuration 1.0 40 0.0 0 Container 20’ GP 40’ GP 0 10 20 30 40 50 Pieces per pallet 26 26 Voltage (V)

Pallets per container 12 28 1000 W/m2 900 W/m2 800 W/m2 Pieces per container 312 728 46 2. SOLAR PANELS

2.a.6. Photovoltaic solar panel HJM250M-32

Product code: PVSPHJM250M32

1062 (41.8) 1016 (40.0) 45 (1.77) 35 (1.38) 80 (3.15) 80

Junction box 4-6*6 (IP65) Waterspout Bar code 90 (3.54) 8-14*9 Mounting slots Lable 130 (5.12) 130 800 (31.5) 800 1580 (62.2) 1580 1300 (51.2) 1300 2- 4 Ground hole

Cable Cable

900mm 900mm

16-3.5*8 Waterspout

9 (0.35) 70 (2.76) 70 (2.76)

PV panel monocrystalline HJM250M-32

The HJM250M-32, HJSOLAR Solar’s 250 watt photovoltaic module features 17-18% encapsulated cell ef- ficiency and 15.2% module efficiency. With a 25 year warranty, the HJM250M-32 has superb durability to withstand rigorous operating conditions. Ideal for grid-connected and remote power systems, the HJM250M- 32 modules offer the maximum usable power per square foot of solar array.

47 2. SOLAR PANELS

Electrical Characteristics Model type HJM250M-32 HJM255M-32 HJM260M-32 Peak power (Pmax) 250W 255W 260W Cell type Mono Crystalline Silicon, 125mm x 125mm Maximum power voltage (Vmp) 50.60 50.80 51.00 Maximum power current (Imp) 4.94 5.02 5.10 Open circuit voltage (Voc) 60.50 60.70 61.00 Short circuit current (Isc) 5.35 5.42 5.51 Maximum system voltage TUV DC 1000V/UL DC600V Temp. Coeff. of Isc (TK Isc) Temp. 0.037 %/ °C Coeff. of Voc (TK Voc) Temp. - 0.34 %/ °C Coeff. of Pmax (TK Pmax) - 0.37 %/ °C Normal operating cell temperature 45 ± 2 °C Power tolerance ±3 % Standard test conditions (STC) AM1.5, 1000W/m2, Module Temperature 25°C

Mechanical Characteristics Dimension (mm) 1580 x 1062 x 45 Weight (kg) 22

96 cells (125 mm x 125 mm) configured geometrically Solar cells for a 8 x 12 matrix connected in series

Output cable length (mm) 900

Front: High transmission 3.2 mm tempered glass. Construction Rear: White backsheet; Encapsulant: EVA.

Features • High module conversion efficiency up to 15.5%. Current-Voltage & Power-Voltage Curve • 25-year limited warranty on power output: 90% power output over 12 years 6.0 300

80% power output over 25 years 5.0 250 Free from defects in materials and workmanship for 5 years

4.0 200 ) • Bypass diode minimizes the power drop caused by shade. • Tempered glass, EVA resin, and weatherproof film, and 3.0 150 Power (W anodized aluminum frame for extended outdoor use. Current (A) 2.0 100 • TUV UL Listings: UL 1703, IEC61215, IEC61730. 1.0 50

0.0 0 0 10 20 30 40 50 60 70 Packing Configuration Voltage (V) 1000 W/m 2 800 W/m 2 500 W/m 2 Container 20’ GP 40’ GP Pieces per pallet 20 20 Pallets per container 12 28 Pieces per container 240 560 48 2. SOLAR PANELS

2.a.7. Photovoltaic solar panel HJM-180D-36

Product code: PVSPHJM180D36

PV panel monocrystalline HJM-180D-36

The HJM185D-36, HJSOLAR Solar’s 185 watt photovoltaic module features 18% encapsulated cell efficiency and 15.5% module efficiency. With a 25 year warranty, the HJM185D-36 has superb durability to withstand rigorous operating conditions. Ideal for grid-connected and remote power systems, the HJM185D-36 modules offer the maximum usable power per square foot of solar array.

49 2. SOLAR PANELS

ELECTRICAL DATA The electrical data applies to standard test conditions (STC): Irradiance at the module level of 1,000 W/m2 with spectrum AM 1.5 and a cell temperature of 25° C

Model type HJM170D-36 HJM175D-36 HJM180D-36 HJM185D-36 HJM190D-36 Peak power(Pmax) 170W 175W 180W 185W 190W Cell type , 125mm x 125mm Number of cells 72 cells in a series Weight 16.5 kg Dimensions 1580×808×45mm Maximum power voltage (Vmp) 36.48 36.59 36.59 36.71 36.71 Maximum power current (Imp) 4.66 4.78 4.92 5.04 5.16 Open circuit voltage (Voc) 43.86 43.92 43.92 44.06 44.06 Short circuit current (Isc) 5.03 5.16 5.31 5.44 5.57 Maximum system voltage TUV DC 1000V/ULDC600V Temp. Coeff. of Isc (TK Isc) Temp. 0.009%/ oC Coeff. of Voc (TKVoc) Temp. -0.34%/ oC Coeff. of Pmax (TK Pmax) -0.37 %/ oC Normal Temperature 45±2 oC

PHYSICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS

6 240

1000W/m˛ 5 900W/m˛ 200

800W/m˛ 4 150

3 120 ower(W) Current(A) P

2 60

1 40

0 0 0 10 20 30 40 50 Voltage(V)

Temperature dependence of Isc, Voc and Pmax

100 ISC

80

Voc

60 Pmax ) c and Pmax(%) c and Vo ower(W

40 P

20 Normalize Isc,

0 -25 0 25 50 75 100

100 Voc )

80

60 c and Pmax(% c and Vo 40 ISC Pmax 20 Normalize Isc,

0

0 200 400 600 800 1000 Irradiance(W/m˛) 50 3. SOLAR HELIOSTATS

3.a. SM44M1HEL3M

Product code: SM44M1HEL3M

Single-Axis Solar Heliostat SM44M1HEL3M

Dual-Axis Solar Heliostat SM44M1HEL3M for application up to 3,1m2 enable cost-effective large-scale sun tracking all over the course of the day with unprecedented accuracy.

51 3. SOLAR HELIOSTATS Technical Capabilities Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 1.250 (H) mm x 1.500 (V) mm

Type of backstructure clamp Toothed scissors gripers 4 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a mirror panel 1 mirror panel with dimensions of 1.250 mm x 2.500 mm with net surface of 3,1 m2

Max. weight of a mirror panel 90 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,1˚

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Communication Data

Type of communication interface USB interface

Networking solution for control from centre RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Turning time interval Tipicaly 6 - 7 s

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 45 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function No Solar Mirror SolReflex® HM3C1M-3 for additional payment 52 3. SOLAR HELIOSTATS

3.b. SM44M1HEL6M

Product code: SM44M1HEL6M

Single-Axis Solar Heliostat SM44M1HEL3M

Dual-Axis Solar Heliostat SM44M1HEL6M for mirror application up to 6,2m2 enable cost-effective large-scale sun tracking all over the course of the day with unprecedented accuracy.

53 3. SOLAR HELIOSTATS Technical Capabilities Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S520M1 with stroke of 520 mm

Type of elevation shaft and stroke Linear Motor SM4S520M1 with stroke of 520 mm

Hour-angle shaft diameter and length Ø48 mm, L=1450 mm (steel)

Turning speed of hour angle shaft 0,039 - 0,063 °/s at no load, see graph

Max. dynamic torque of the hour-angle shaft 200 - 330 Nm depend from HA, see graph

Max. dynamic torque of elevation shaft 330 Nm - 400 Nm depend from EA, see graph

Destructive torque of the hour-angle shaft 750 Nm - 1250 Nm, depend from HA, see graph

Destructive torque of elevation shaft 1250 Nm - 1500 Nm, depend from HA, see graph

Backstructure size 2.500 (H) mm x 1.500 (V) mm

Type of backstructure clamp Toothed scissors gripers 8 pcs

Tube diameter for mounting Ø60 - 68 mm (not included with kit)

Max. dimensions of a mirror panel 2 mirror panels with dimensions of 1.250 mm x 2.500 mm with net surface of 6,2 m2

Max. weight of a mirror panel 90 kg

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,1˚

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Communication Data

Type of communication interface USB interface

Networking solution for control from centre RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24 VDC ± 10% (2A current capacity)

Backup battery CR 2512 coin

Turning time interval Tipicaly 6 - 7 s

Max. consumption during the operation of the hour-angle shaft 500 mA @ 330 Nm, see graph

Max. Current of elevation shaft 500 mA @ 400 Nm, see graph

Standby consumption (when is not moving) 20 mA ± 25% @ 24V

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 245 (W) x 202 (H) mm

Product weight 45 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function No Solar Mirror Solar Mirror SolReflex® HM3C1M-3 for additional payment 54 3. SOLAR HELIOSTATS

3.c. SM44M3HEL25M

Product code: SM44M3HEL25M

Single-Axis Solar Heliostat SM44M1HEL25M

Dual-Axis Solar Heliostat SM44M1HEL25M for mirror application up to 25m2 enable cost-effective large-scale sun tracking all over the course of the day with unprecedented accuracy.

55 3. SOLAR HELIOSTATS Technical Capabilities Mechanical Capabilities

Number of turning axis Dual-Axis

Hour Angle Limit 100˚, software and hardware limit

Elevation angle 15-90˚, adjustable start

Type of hour-angle engine Linear Motor SM4S900M3 with stroke of 900 mm

Type of elevation shaft and stroke Linear Motor SM4S900M3 with stroke of 900 mm

Hour-angle shaft diameter and length Square tube 110x110 mm, L=5000 mm (steel)

Turning speed of hour angle shaft /

Max. dynamic torque of the hour-angle shaft /

Max. dynamic torque of elevation shaft /

Destructive torque of the hour-angle shaft /

Destructive torque of elevation shaft /

Backstructure size /

Type of backstructure clamp Toothed scissors gripers 48 pcs

Tube diameter for mounting Square tube 200x200 mm, H=3500 mm (steel)

Max. dimensions of a mirror panel 8 mirror panels with dimensions of 1.250 mm x 2.500 mm with net surface of 25 m2

Max. weight of a mirror panel /

Estimated service life 5.000 rotations of 200° (100°E + 100°W), or 10 years

Positioning System Data

Tracking accuracy <0,1˚

Operating Protocol TdAPS (Time derived Astronomical Positioning System)

Type of positioner Din Rail positioner MICRO and externor cables

Type of timer GMT clock with EOT and calendar

Type of application program for supervision and setting Solar tracking system monitor via Helios Analytics

Setting and changing data via PC Yes, It can be setup up to 1000 parameters

Monitoring possibility via PC Yes, It can be setup up to 1000 parameters

Turned on the position sent from PC Yes, it turn on position sent from PC, also all other setting can be commanded with string sent from PC

Communication Data

Type of communication interface USB interface

Networking solution for control from centre RS485

Firmware - Software

Upgrading possibility via PC Yes, firmware via PC with help of web wizard

Electrical Data

Motor Power Supply 24VDC +/- 15% 4A (5A current capability)

Backup battery CR 2512 coin

Turning time interval 1 minute (0.25°)

Max. consumption during the operation of the hour-angle shaft /

Max. Current of elevation shaft /

Standby consumption (when is not moving) 60mA @ 24 VDC

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included with kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Max. safe wind speed <130 km/h (tested up to 180 km/h)

Corrosion, weather and chemical resistance

Hot-dip galvanizing (HDG, EN ISO 1461) 75 - 100 μm (equivalent of 50 years)

Packaging

Dimensions of a packed product /

Product weight /

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Anti-Shadowing Function No Solar Mirror Solar Mirror SolReflex® HM3C1M-3 for additional payment 56 4. SOLAR LINEAR MOTORS

4.a. Motor SM4S520M1

Product code: Motor SM4S520M1

Professional Solar Linear Actuator - Motor SM4S520M1

Professional Solar Linear Actuator - Motor SM4S520M1. Standard precision 0,5 degrees. Advanced precision 0,1 degrees for addtional payment.

Suitable for PV panels, concentrators - CPV and Heliostats. Heliostats for addtional payment. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included. 57 4. SOLAR LINEAR MOTORS

4.a. Motor SM4S520M1

Technical Capabilities

Mechanical Capabies

Construction material of linear motor Stainless steel tubes and spindle and high carbon steel

Spindle type and material ACME stainless spindle

Stroke lenght 520 mm

Max. static load 3400 N

Dynamic load capacity 1000 N

Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load 0,9 mm/s at no load, 0,4 mm/s at max. load

Resolution 380,8 pulses/mm (min step is 0,0026 mm)

Backlash max 0,2 mm

Electrical Data

Motor Power Supply 24VDC +/- 15% 0,2A (0,5A current capability)

Backup battery /

Turning time interval /

Power consumption in operation Tipicaly 3-6 W, max 10 W

Standby consumption (when is not moving) /

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,0 mm2 (not included in kit)

Environmental Data

Operating temperature -25°C to +70°C (optionally with artic grease for teperatures from -40°C up to +70°C)

Operation at humidity 0% to 100%, relative humidity

Corrosion, weather and chemical resistance

Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation

Packaging

Dimensions of a packed product 1box of 1000(L) x 80(W) x 60(H) mm

Product weight 3,46 kg + 1 kg box weight

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Heliostat usage Yes, for additional payment

CPV usage (concentrated PV usage) Yes, all types including round parabolic - for additional payment

Guarantee time 2 years as standard, 5 years for +20% - for additional payment, 10 years for +35% - for additional payment

58 4. SOLAR LINEAR MOTORS

4.b. Motor SM4S900M3C3 - with Clamp C3

Product code: Motor SM4S900M3C3

Professional Solar Linear Actuator - Motor SM4S900M3C3

Professional Solar Linear Actuator - Motor SM4S900M3C3. Standard precision 0,5 degrees. Advanced preci- sion 0,1 degrees for addtional payment.

Suitable for PV panels, concentrators - CPV, and heliostats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included. 59 4. SOLAR LINEAR MOTORS

4.b. Motor SM4S900M3C3 - with Clamp C3

Technical Capabilities

Mechanical Capabies

Construction material of linear motor Stainless steel tubes and spindle and high carbon steel

Spindle type and material ACME stainless spindle

Stroke lenght 900 mm

Max. static load 15000 N

Dynamic load capacity 8000 N

Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load 2,33 mm/s

Resolution 294 pulses/mm (min step is 0,0034 mm)

Backlash max 0,15 mm

Electrical Data

Motor Power Supply 24VDC +/- 15% 4A (5A current capability)

Backup battery /

Turning time interval /

Power consumption in operation Tipicaly 20-50 W, max 100 W

Standby consumption (when is not moving) /

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included in kit)

Environmental Data

Operating temperature -25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)

Operation at humidity 0% to 100%, relative humidity

Corrosion, weather and chemical resistance

Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 80 (W) x 80 (H) mm

Product weight 8,5 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Heliostat usage Yes

CPV usage (concentrated PV usage) Yes, all types including round parabolic

Guarantee time 2 years as standard, 5 years for +20% *** 10 years for +35% ***

60 4. SOLAR LINEAR MOTORS

4.c. Motor SM4S900M3C4 - with Clamp C4

Product code: Motor SM4S900M3C4

Professional Solar Linear Actuator - Motor SM4S900M3C4

Professional Solar Linear Actuator - Motor SM4S900M3C4. Standard precision 0,5 degrees. Advanced preci- sion 0,1 degrees for addtional payment.

Suitable for PV panels, concentrators - CPV, and heliostats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included. 61 4. SOLAR LINEAR MOTORS

4.c. Motor SM4S900M3C4 - with Clamp C4

Technical Capabilities

Mechanical Capabies

Construction material of linear motor Stainless steel tubes and spindle and high carbon steel

Spindle type and material ACME stainless spindle

Stroke lenght 900 mm

Max. static load 15000 N

Dynamic load capacity 8000 N

Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load 2,33 mm/s

Resolution 294 pulses/mm (min step is 0,0034 mm)

Backlash max 0,15 mm

Electrical Data

Motor Power Supply 24VDC +/- 15% 4A (5A current capability)

Backup battery /

Turning time interval /

Power consumption in operation Tipicaly 20-50 W, max 100 W

Standby consumption (when is not moving) /

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included in kit)

Environmental Data

Operating temperature -25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)

Operation at humidity 0% to 100%, relative humidity

Corrosion, weather and chemical resistance

Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 80 (W) x 80 (H) mm

Product weight 8,5 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Heliostat usage Yes

CPV usage (concentrated PV usage) Yes, all types including round parabolic

Guarantee time 2 years as standard, 5 years for +20% *** 10 years for +35% ***

62 4. SOLAR LINEAR MOTORS

4.d. Motor Motor SM4S900M3NC

Product code: Motor SM4S900M3NC

Professional Solar Linear Actuator - Motor SM4S900M3NC

Professional Solar Linear Actuator - Motor SM4S900M3NC. Standard precision 0,5 degrees. Advanced preci- sion 0,1 degrees for addtional payment.

Suitable for PV panels, concentrators - CPV, and heliostats. Usage: small and large powerplants, on-grid at roof on houses or factories, cottages, solar tower powerplant, where solar panels are connected in serial and output is connected directly to inverter or an external charging device. Solar tracker anti-shadowing software function included. 63 4. SOLAR LINEAR MOTORS

4.d. Motor Motor SM4S900M3NC

Technical Capabilities

Mechanical Capabies

Construction material of linear motor Stainless steel tubes and spindle and high carbon steel

Spindle type and material ACME stainless spindle

Stroke lenght 900 mm

Max. static load 15000 N

Dynamic load capacity 8000 N

Rod end type Spherical bearing with hole dia. Ø12 mm with pivot angle of 13º

Speed at no load 2,33 mm/s

Resolution 294 pulses/mm (min step is 0,0034 mm)

Backlash max 0,15 mm

Electrical Data

Motor Power Supply 24VDC +/- 15% 4A (5A current capability)

Backup battery /

Turning time interval /

Power consumption in operation Tipicaly 20-50 W, max 100 W

Standby consumption (when is not moving) /

Power supply connection 1 piece of 2 Wire Cable with an Internal Cu Conductor of 1,5 mm2 (not included in kit)

Environmental Data

Operating temperature -25°C to +85°C (optionally with artic grease for teperatures from -40°C up to +85°C)

Operation at humidity 0% to 100%, relative humidity

Corrosion, weather and chemical resistance

Corrosion Protection PLASOX® plasmanitriding with subsequent oxidation

Packaging

Dimensions of a packed product 1 box of 1600 (L) x 80 (W) x 80 (H) mm

Product weight 8,5 kg

Quality Certificates

International Protection Rating (IEC 60529) IP33

Electromagnetic Compatibility (EMC Directive 89/336/EEC) Yes

Low Voltage Equipment Directive (EEC Council Directive 73/23/EEC) Yes

Optional Properties

Heliostat usage Yes

CPV usage (concentrated PV usage) Yes, all types including round parabolic

Guarantee time 2 years as standard, 5 years for +20% *** 10 years for +35% ***

64 5. SOLAR POSITIONERS

5.a. SOLAR POSITIONER NANO

Product code: POZSOL34A1DR (Solar Positioner NANO works only in connection with Solar server SIGMA!!!)

Solar Positioner NANO A for Dual Axis Tracking With even better communication, usability and accuracy, the Solar Positioner NANO A set a new Positioning Accuracy Standards. With easy installation, safe operation, a simplified assembly concept, and RS485 plant communication: the new generation of positioners is ideally suited in mid-sized and large stand-alone grids. With the Sigma Server, Solar Positioner NANO A creates complete, integrated system for monitoring, diagnosis and configuration of the PV plant.

Professional • Drive and positioning of Dual Axis Solar Trackers • Integration of Sat Control equipment into existing control-room technology

Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability

Reliable • Direct communication with the Sigma Solar Server via RS485 Service Interface • Meets the requirements of the EU Medium-Voltage Directive for grid safety management 65 5. SOLAR POSITIONERS

5.a. SOLAR POSITIONER NANO

Technical Capabilities

Operation

Geometrical Operation Dual Axis Positioner

Type Slave Positioner

Communication

Tracker communication RS485 MODBUS

Interfaces

RS485 2 Pin Connector (Grounding Option)

Max. number of controlled devices

Solar Tracker 64

Max. communication range

RS485 1000 m

Power supply

Power supply External Power Supply

Input voltage 24VDC +/- 10%

Power consumption Type 4 W / max. 12 W / 0,5 W Stand By

Environmental conditions in operation

Ambient temperature -20 °C ... +60 °C

Relative air humidity 0 % ... 45 %, non-condensing

General data

Dimensions (W / H / D) in mm 110 / 55 / 17

Weight 100 g

Mounting location Indoors

Mounting options DIN rail mounting

Status display LEDs

Hall signals 2 Hall signals per Axis

End switches 2 Switches per Axis (one required, one optional)

Manual buttons 2 (East-West, Reference)

Upgrading In The Field by RS485 MODBUS

Languages

Software language English

Language versions – manual German, English, French, Italian, Spanish; Slovenian

Features

Warranty 5 years

Certificates and approvals www.Solar-Motors.com

66 5. SOLAR POSITIONERS

5.b. SOLAR POSITIONER MICRO

Product code: POZSOL36A1DR Solar Positioner MICRO (stand alone positioner) is settable with Helios Analytics monitoring programme!!!

Solar Positioner MICRO for Dual Axis Tracking With even better communication, usability and accuracy, the Solar Positioner MICRO set a new Positioning Accuracy Standards. With easy installation, safe operation, a simplified assembly concept, USB tracker and RS485 plant communication: the new generation of positioners is ideally suited in single and middle size stand- alone grids. With the Sigma Server, Solar Positioner MICRO creates complete, integrated system for monitor- ing, diagnosis and configuration of the PV plant.

Professional • Drive and positioning of Dual Axis Solar Trackers • Integration of Sat Control equipment into existing control-room technology

Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability

Reliable • Direct communication with Helios Analytics • Meets the requirements of the EU Medium-Voltage Directive for grid safety management 67 5. SOLAR POSITIONERS

5.b. SOLAR POSITIONER MICRO

Technical Capabilities OperationOperationnergy measurement of two equal solar panels (fixed and motorized) Geometrical Operation Dual Axis Positioner TypeThree equal solar panels were exposed to theStand realAlone Positioner sun and conversed electrical power was Communicationmeasured. TrackerTest communication conditions: USB, RS485 MODBUS InterfacesSolar panels (both): 0.9 kWp (producer spec. at AM 1.5) RS485Date: July 2010 2 Pin Connector (Grounding Option) Max. number of controlled devices Time: 4:00 to 20:00 (sun time) Solar Tracker 1

Max.Geo. communication Latitude: range 46° N

RS485Weather conditions: sunny, but not totally1000 clear m

PowerResults: supply

PowerAverage supply energy of fixed: 3762,0Wh External Power Supply InputAverage voltage energy of motorized: 6093,0Wh 24VDC +/- 10% PowerNote: consumption sum of motor energy consumption through2Type 4 W / max. all 12 dayW / 0,5 Wis Stand 17.52Wh By or 0.29% of all col- Environmentallected energy. conditions in operation Ambient axis temperature or dual axis Solar Tracker with accuracy-20 °Cbetter ... +60 °C than 0,5 deg and backstructure for 3 Relativepieces air humidity of solar panels dimensions 0,99 m x 01,95 % ... 45 %, non-condensingm and weight of 30 kg max each. So to- Generalgether data for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- Dimensionsstats. (WUsage / H / D) in mmat homes: on-grid at roof on houses,110 / 55 / 17 trafic signalisations, street light, cot- Weight 100 g

Mounting location Indoors

Mounting options DIN rail mounting

Status display LEDs

Hall signals 2 Hall signals per Axis

End switches 2 Switches per Axis (one required, one optional)

Manual buttons 2 (East-West, Reference)

Upgrading In The Field by RS485 MODBUS, or by USB

Languages

Software language English

Language versions – manual German, English, French, Italian, Spanish; Slovenian

Features

Warranty 5 years

Certificates and approvals www.Solar-Motors.com

68 5. SOLAR POSITIONERS

5.c. Sigma Solar Server

Product code: POZSOLSIG1 (Sigma Solar Server works in connection with Solar Positioner NANO!!!)

The standardized data interface for large-scale systems

Large-scale plants and PV power utility stations require customized monitoring solutions and need to link sys- tems and components into one joint control system. Sigma Server set new communication standard in the field of automation technology, that enables simple and reliable data exchange between products and applications. With the Sigma Solar Server, Sat Control equipment can be very easily integrated into compatible systems.

Overview

Professional • Visualization, control and monitoring of large-scale plants • Integration of Sat Control equipment into existing control-room technology

Flexible • Data interface in accordance with the communication standards in the field of automation technology • Simple and fast installation, high reliability

69 5. SOLAR POSITIONERS

5.c. Sigma Solar Server

Technical Capabilities Communication2 Real energy measurement of two equal solar panels (fixed and motorized) Communication with Enigma Analytics Ethernet PCThree communication equal solar panels were exposed to theEthernet real sun and conversed electrical power was Trackermeasured. communication RS485 InterfacesTest conditions: AnalogSolar and digitalpanels inputs (both): 0.9 kWp (producer spec.3 analog inputsat /AM 3 open 1.5) collector outputs EthernetDate: July 2010 10/100 Mbit, RJ45 RS485 2 Pin Connector (grounding option) Time: 4:00 to 20:00 (sun time) Max. number of controlled devices

SolarGeo. Tracker Latitude: 46° N 64

Max.Weather communication conditions: range sunny, but not totally clear

EthernetResults: 100 m

RS485Average energy of fixed: 3762,0Wh 1000 m PowerAverage supply energy of motorized: 6093,0Wh PowerNote: supply sum of motor energy consumption throughExternal Power all Supply day is 17.52Wh or 0.29% of all col- Inputlected voltage energy. 12VDC - 24VDC Power axis consumption or dual axis Solar Tracker with accuracyType 4better W / max. 12 Wthan 0,5 deg and backstructure for 3 Environmentalpieces ofconditions solar in operation panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- Ambientgether temperature for 5,8 m2 solar panel surface. A Suitable-20 °C ... +60 °Cfor PV panels, concentrators - CPV, helio- Relativestats. air humidity Usage at homes: on-grid at roof on houses,0 % ... 45 %, non-condensing trafic signalisations, street light, cot- Memory

Internal 0,5 MB

External SD card 2 GB

General data

Dimensions (W / H / D) in mm 110 / 55 / 17

Weight 100 g

Mounting location Indoors

Mounting options DIN rail mounting

Status display LEDs

Languages

Software language English

Language versions – manual German, English, French, Italian, Spanish; Slovenian

Features

Operation Integrated Web server (Internet browser)

Warranty 5 years

Certificates and approvals www.Solar-Motors.com

70 5. SMPS Power supply TDK

5.d. Lambda; 1. DPP 50-24, 2. DPP 100-24, 3. DPP 480-24-3

1. TDK - Lambda DPP 50-24

A 50 watt, enclosed frame, single output DIN Rail mounted AC/DC power supply. This rail mount power sup- ply has a 85-264 AC volt Wide-range input with power factor correction. The output(s) are rated 24.00v at 2.10a. It is industrial rated with an operating temperature range of -10 - 71 °C and up to 86% efficiency. The DPP50-24 is Rohs 6/6 compliant and backed by a 2 year warranty.

Overview:

• 5 to 48 V Outputs • 50 mV Ripple and Noise • Parallel Up to 3 Units (100 W and Up) • Convection Cooled from –10°C Up to +71°C • Active Power Factor Correction (PFC) • Universal/Auto Select AC Input • Input Transient Protection IEC61000-4 • UL/CSA/EN60950-1 and CE Mark Safety Approvals • UL1310 Class 2 • UL508 Listed and Class 1, Div. 2

3. TDK - Lambda DPP 100-24

A 100 watt, enclosed frame, single output DIN Rail mounted AC/DC power supply.

Overview:

• PSU, AC/DC, DIN RAIL, 24V, 100W • Power Supply Output Type: Adjustable • No. of Outputs: 1 • Output Voltage: 24V • Output Current: 4.2A • Power Rating: 100W • Input Voltage VAC: 85V AC to 132V AC/170V AC to 264V AC • Length: 96.7mm • Width: 22.8mm • Height: 75mm • SVHC: No SVHC (20-Jun-2011) • Efficiency: 87% • Input Voltage: 85V AC to 132V AC , 170V AC to 264V AC • Output Voltage Max: 28.5V • Output Voltage Min: 22.5V

71 5. SMPS Power supply TDK

Technical Capabilities Operationnergy2. TDK - Lambdameasurement DPP 480-24 of two (DIN equal Rail solar24V 20A panels 480W) (fixed and motorized)

Three equalA 480 solarwatt, enclosedpanels wereframe, exposed single output to theDIN realRail mounted sun and AC/DC conversed power supply. electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: Overview: July 2010 Time: • PSU, AC/DC, DIN 4:00 RAIL, to 24V, 20:00 480W, (sun 3PH time) Geo. Latitude:• Power Supply Output 46° N Type: Fixed Weather• conditions:No. of Outputs: sunny,1 but not totally clear Results:• Output Voltage: 24V Average• energyOutput Current: of fixed: 20A 3762,0Wh Average• energyPower Rating: of motorized: 480W 6093,0Wh Note: sum• Input of motorVoltage energyVAC: 340V consumption AC to 575V AC through all day is 17.52Wh or 0.29% of all col- lected energy.• Length: 111.9mm axis or •dual Width: axis 150mm Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of• Height:solar panels 124mm dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- • SVHC: No SVHC (20-Jun-2011) gether for• Efficiency: 5,8 m2 solar90% panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats. Usage• Input at Voltage: homes: 340V on-grid AC to 575Vat roof AC on houses, trafic signalisations, street light, cot- • Output Voltage Max: 28.5V • Output Voltage Min: 22.5V

72 5. JUNCTION BOX

5.e. Junction Box (j-box) Set

Product code: JBOXSETSPMN1-TC

Junction Box (j-box) Set - Smart solution for solar tracker positioner connection

The Sat Control’s Junction Box (j-box) Set is designed to be compact and versatile without any compromise on its safety and reliability standards: Expanding on the proven technology of Sat Control’s positioning devices, it separate of both mechanical and electronic components of solar trackers and replaces Sat Control’s integrated positioner with external din rail positioners. Material wall mounting boxes: made of ABS technopolymer with high resistance to UV rays and broad temperature range enable its use even under extreme climatic conditions. Particular bottom guides for DIN rail, terminal block and plates enable its easy installation and make positioner settings entirely foolproof.

User-friendly

• Separate of both mechanical and electronic components • Easy status reports and visualization via Transparent Lid • Can be integrated into existing and new Solar Trackers/PV plants

Simple

• Easily accessible connection area • Comfortable installation and commissioning • Free choice of mounting location

Durable

• High protection class IP65 73 5. JUNCTION BOX & CONNECTION BOARD SESTIV 39B

5.e. Junction Box (j-box) Set

Technical Capabilities General2 Real data energy measurement of two equal solar panels (fixed and motorized) Internal dim. (W / H / D) in mm 190 / 140 / 70 Weight (without cables) 500 g MaxThree ø holes possibleequal solar panels were exposed to the4 xreal ø 18 mm sun and conversed electrical power was Lidmeasured. screws (no. and type) 4 Insulated sealable Hinged (Inox) Characteristics Halogen Free MountingTest siteconditions: outdoors MountingSolar options panels (both): 0.9 kWp (producer spec.DIN-Rail at mounted AM interfaces1.5) AmbientDate: Conditions July 2010 Ambient temperature -40 °C ... +85 °C / -40 °F ... +185 °F RelativeTime: air humidity 4:00 to 20:00 (sun time)100 % relative humidity (non-condensing) DegreeGeo. of protection Latitude: (according to IEC 60529) 46° N IP65 FeaturesWeather conditions: sunny, but not totally clear SmoothResults: Sided junction box - Screwed Transparent Lid - IP 56 1 Din metal mounting rail 180(L) mm 1 MetricAverage Thread Cable energy Glands Pg 9 TDof (16 fixed:mm) TL (8 mm) 3762,0Wh 4 DINAverage Rail Mounted Fuseenergy Holder VSV of 4 4 motorized:mm2 440 V 6093,0Wh 1 DIN Rail Terminal Block VS 4-PE 4 mm 1 DINNote: Rail Bus barsum Terminal of Block motor 6x9 -–10P energy consumption through2 all day is 17.52Wh or 0.29% of all col- Warranty:lected 5 / 10energy. / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt. Certificates and approvals www.Solar-Motors.com Accessories axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 Positionerspieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- Solargether Positioner for 2-axis 5,8mod. MICRO, m2 USB-RS485, solar panelDIN rail surface. A Suitableopt. for PV panels, concentrators - CPV, helio- Solar Positioner 2-axis mod. NANO, RS485, DIN rail opt. Cablesstats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot- Int. Cable SM4M3 w con 7pins->OPEN, L=opt. 2x1+5x0.22 opt. (1 or 2 pcs depend on Actuators - length is at request)

5.f. Connection Board Sestiv 39B

Product code: SESTIV39B

74 5. USB 2.0 to RS485

5.g. USB 2.0 to RS485 Mini Adapter with Terminal Block

Product code: USB2RS485

USB 2.0 to RS485 Mini Adapter with Terminal Block

Specifications

• USB Specification 2.0 Compliant • Supports RS485 serial Interface • Data Transfer Rates from 300bps to 3Mbps • Enhanced ESD Specification: +/-15KV Human Body Model, +/-15KV IEC1000-4-2 Air Discharge, +/-8KV• • IEC1000-4-2 Contact Discharge • Supports Windows 98SE/ME/2k/XP/Vista/7/x64, Mac OSX, Linux 2.6.9+

Includes

• USB to RS485 Adapter • DB9 to 4-pin Terminal Block adapter • Driver Disk • 0,8m USB extension cable

75 5. CABLE USB2.0 - USB-A

5.h. Cable USB2.0 - USB-A -> Micro-B, 1,8m, black

Technical Capabilities 2 Real energy measurement of two equal solar panels (fixed and motorized) Product code: KABUSBA-MB1.8 Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

Cable USB2.0 - USB-A -> Micro-B, 1,8m, black

Specifications

• CABLE, USB A M - MICRO B M, 1.8M • Cable Assembly Type:Computer Cables • Cable Length - Metric:1.8m • Cable Length:1.8m • Colour:Black • Connector Type A:USB A Male • Connector Type B:USB micro B male • Weight (kg): 0.06

76 5. WIND SENSOR

5.i. Wind sensor WS XS Vestamatic

Product code: WSVM01100310

Wind sensor WS XS Vestamatic

Specifications

• Wind sensor for measuring wind speed • For plastic bracket mounting • Compatible with all Vestamatic central, awning and blind controls

Includes

• Wind sensor WS XS Vestamatic WSVM01100310 / 383106390209

77 5. CABLE USB2.0 - USB-A

5.j. Plastic mounting bracket for wind sensor

Technical Capabilities 2 Real energy measurement of two equal solar panels (fixed and motorized) Product code: WSBWM01271020 Three equal solar panels were exposed to the real sun and conversed electrical power was measured. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

Wind sensor WS XS Vestamatic

Specifications

• Wind sensor for measuring wind speed • For plastic bracket mounting • Compatible with all Vestamatic central, awning and blind controls

Includes

• Wind sensor WS XS Vestamatic WSVM01100310 / 383106390209

78 6. GROUND SCREWS

6.a. Ground Screw

Product code: ZV76X60X1400

Ground Screws

Ground Screws made of high quality hot-galvanized steel, are widely used as strong supports for many ap- plications: flag poles and masts, timber construction, fencing systems, event structures, boards and banners, gardens and parks, Roads and traffics, sheds and containers etc. For us the important thing is they can be the easy and strong support for Solar Trackers and PV systems.

Key Features

• Foundation screws for any type of soil • Ideal for Photovoltaic Installations • Solid, forged and galvanized steel with welded screw threads • Stability is accomplished by means of compression during insertion to the ground. No other digging is required. • Production process is certified ISO9001:2008, ensuring the highest quality construction, reliability and flexibility.

Advantages

• No cement foundation or any other concrete construction needed • Optimum earthing accomplished by connecting the vertical parts with tin-plated copper wire, avoid ing any additional ground wiring, creating that way a solid, low resistance grounding Ground screws come with a 25-yeat anti-corrosion guarantee • No construction permit required • All systems are adjustable to customer requirements. • All systems are assembled using specialized personnel and machinery • Time saving and cost efficient • Can be subject to weight loads immediately • Environmentally friendly 79 6. GROUND SCREWS

6.a. Ground Screw

Technical Capabilities Model type Ground screw 76X1400 L=1400 d=76/60

Length of ground screw 1400 mm Outside diameter of ground screw 76,45mm x 2,6 mm (inner dia. 71mm with zinc)

Max. diameter of tube you can put in D63,5 mm L=2m

Screw thread size and pitch 620 mm Surface treatment protection type and thick Hot bath zincking 200 um EN ISO1461 80 6. GROUND SCREWS

6.a. Ground Screw

81 6. GROUND SCREWS

6.b. SET Ground Screws

Product code: SETZV14C2X1SP

SET Ground Screws

SET Ground Screws provide a solid foundation whatever your project needs. Our SET Ground Screws is engi- neered for easy installation and provide years of dependable service. There is no need for gigging or laying a concrete foundation, drastically reducing cost and time associated with installation. SET Ground Screws also lessen the environmental impact of your solar project, allowing your panel arrays to blend in more naturally into terrain. Also importantly, SET Ground Screws are easily removable and reusable.

Set Components are:

• Ground Screw: 76x1400mm • Tube D60 2x1000 mm • Junction Clamp d=76/60

Key Features

Convenience

• Easy to install and use • No gigging or poring of concrete needed • Can be used in all types of soil • Fastest possible installation time • Ready to use immediately after installation

Environmentally friendly

• Compact design ensures the least impact on ground and surrounding area • Minimal site preparation needed • Since there is no need for concrete, the ground remains intact after screws are removed

Durability

• Made with galvanized steel and welded screw threads • Can be subject to weight loads immediately after installation • Provides solid foundation in all weather conditions • 25-year anti-corrosion guarantee

Value

• Reduced installation time and cost • Minimal materials required; provides the most cost effective foundation solution • Lowers system buy back times • Removable and reusable

82 6. GROUND SCREWS

6.b. SET Ground Screws

Product code: SETZV14C2X1SP

Technical Capabilities Model type SET Ground Screws 76x1400 with tube D60 2x1000 with junction clamp

Length of ground screw 1400mm + 2 x tube D60,3 x 1000 + junction clamp Outside diameter of ground screw 76,45mm x 2,6mm + 2 x D60,3 x 3,25mm

Max. diameter of tube you can put in D63,5 x 3,25mm L=2000mm

Screw thread size and pitch 620mm 83 Surface treatment protection type and thick Hot bath zincking Zn 200 um EN ISO1461 6. GROUND SCREWS

6.b. SET Ground Screws

84 7. MONITORING SYSTEM - Helios Analytics

7.a. Helios Analytics

Product code: PRGSIGHELANA1

Professional management, monitoring and presentation of solar tracker

System management, monitoring, remote diagnosis, data adjusting and visualization: the Helios Analytics is the high-performance communication hub for single- to small-scale of solar trackers. It continuously display all the data from the solar trackers on the system side, thereby keeping you informed of the system‘s status at any given time. The Helios Analytics is a multi-functional, energy-efficient data system which offers importing and exporting settings data for solar trackers.

Overview

Safe • Remote monitoring, diagnosis and configuration of the solar trackers • Quick detection of malfunctions and notification in case of a failure • Powerful data system for importing and exporting all trackers setting data

User-friendly • Central administration of all customer and tracker data • Easy remote access via PC • Easy to understand reporting

85 7. MONITORING SYSTEM - Helios Analytics

7.a. Helios Analytics

2 Real energy measurement of two equalTechnical solar Capabilities panels (fixed and motorized) Languages SoftwareThree language equal solar panels were exposedEnglish to the real sun and conversed electrical power was Languagemeasured. versions – manual German, English, French, Italian, Spanish, Slovenian System requirements Test conditions: Windows XP (installed version of Microsoft .NET Framework > 2.0 is SupportedSolar operating panels systems (both): 0.9 kWp (producerrequired with 64 spec. bit systems), at Windows AM Vista1.5) (32-Bit and 64-Bit), Date: July 2010 Windows 7 (32-Bit and 64-Bit) Hardware (minimum requirements) Time: 4:00 to 20:00 (sun time) Processor PIII 800 MHz (XP) / P4 1 GHz (Vista)

MainGeo. Memory Latitude: 46° N 512MB (XP) / 1 GB (Vista)

FreeWeather hard disk space conditions: sunny, but not265 MBtotally (240 MB .Net clear / 25 MB application)

ResolutionResults: 1024 x 768 pixels

ColorAverage depth energy of fixed: 3762,0Wh256 colors CommunicationAverage energy of motorized: 6093,0Wh TrackerNote: communication sum of motor energy consumptionUSB 2.0, CAN through BUS 2.0 A all day is 17.52Wh or 0.29% of all col- Typelected energy. IP address, URL (e.g., DynDns) Max. axis number or of devicesdual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 USBpieces 2.0 / CAN of BUS solar2.0 A panels dimensions 0,991 / up to 2000m trackersx 1,95 m and weight of 30 kg max each. So to- RS485gether / Ethernet for 5,8 m2 solar panel surface./ A Suitable for PV panels, concentrators - CPV, helio- Max.stats. communication Usage range at homes: on-grid at roof on houses, trafic signalisations, street light, cot- USB 2.0 / CAN BUS 2.0 A 5 m / 500 m (Twisted Pair Cable with cross section 0,7 mm2)

RS485 / Ethernet /

Software

Type Exe

Other Zip

Client Software Requirements No installation-dependent requirements for the operation

System information

Tracker overview Ideally suited for an overview over the solar tracker by presentation of the most important data

System settings Simple parameter setting for an entire device

Summary of current device data. The display of minimum and maximum values, sums and averages (depicted for every device category) provides Current system values the operator with detailed information about the current status of their solar tracker

Device information

Device overview The most important device information at a single glance

Device settings Individual parameter adjustment for each device

Current device values Detailed information on the current values of the selected device

Information displayed

General information Time, date

Power supply voltage, current motion, position, error codes, angle, System Data tracker version, tracker type

Advanced System Data

A1, A2, A3, A4, A5 , A6, B1, B2, min range A, max range A, gear ratio A, Motor A I motor max A, coordinate mode A, geometry mode A, I motor factor A, night position A, go to reference A

A1, A2, A3, A4, A5 , A6, B1, B2, min range B, max range B, gear ratio B, Motor B I motor max B, coordinate mode B, geometry mode B, I motor factor B, night position B, go to reference B

Night position time, link, U supply factor , group, conf. flags, SN1, SN2, SN3, Common settings can ID, options, run, delay n.p., run delay, panel wide, panel space, rtc correction, H target angle, V target angle

Individual set-up options

Values Three configurable pre-defined positions for snow, wind, etc.

The weather station for PV plants Current system values / 86 8. SAT CONTROL WEBSHOP

8.a. Sat Control WebShop

Profit from our new online shop!

Conveniently order Sat Control quality from home and profit from: • A wide range of products and services • Surprisingly low prices • The high level of quality of quality of the products and components used and • The schedule effectiveness you have become accustomed to

The Sat Control WebShop. 24/7 one-stop shopping for all-round solutions Tailor-made to your needs fast and at the same level of high quality.

87 8. SAT CONTROL WEBSHOP

8.a. Sat Control WebShop

2 Real energy measurement of two equal solar panels (fixed and motorized) Making a Payment

ThreeThe following equal solaroutlines panels the how were you canexposed make ato payment the real through sun andthe WorldPay conversed Payment electrical Service power and how was we measured.deal with the transaction. Test conditions: Solar panels (both): 0.9 kWp (producer spec. at AM 1.5) Date: July 2010 Time: 4:00 to 20:00 (sun time) Geo. Latitude: 46° N Weather conditions: sunny, but not totally clear Results: Average energy of fixed: 3762,0Wh Average energy of motorized: 6093,0Wh Note: sum of motor energy consumption through all day is 17.52Wh or 0.29% of all col- lected energy. axis or dual axis Solar Tracker with accuracy better than 0,5 deg and backstructure for 3 pieces of solar panels dimensions 0,99 m x 1,95 m and weight of 30 kg max each. So to- gether for 5,8 m2 solar panel surface. A Suitable for PV panels, concentrators - CPV, helio- stats. Usage at homes: on-grid at roof on houses, trafic signalisations, street light, cot-

How does the WorldPay Payment Service work?

1. A shopper visits an e-commerce website and selects the products/services that they would like to buy.

2. The shopper then proceeds to the merchant’s checkout with their shopping basket. This generates a sum- mary description of the purchase that is sent to WorldPay for payment processing. This submis sion is often referred to as the “purchase token”.

3. The shopper is redirected to WorldPay’s secure server where they are presented with a series of payment pages, enabling them to choose their payment method and enter their payment details.

4. WorldPay records the shopper’s payment details against the details submitted in the purchase token, to produce a transaction.

5. WorldPay forwards the transaction details to the card issuer for authentication. The issuer returns an authorised or declined response to WorldPay and a payment response page is then displayed to the shopper.

6. If the transaction was successful, WorldPay will also send the shopper a confirmation email, confirming the transaction details.

For more informations about paying through WorldPay, and for information on the status of your payments for pur- chases made at one of the shops that uses the WorldPay Payment Service, please visit: www.rbsworldpay.com

88 Published by and copyright © 2011: Sat Control d.o.o. Pozenik 10, SI-4207 Cerklje Slovenia

For more information, please contact our Customer Support Center. Phone: +386 4 281 62 15 Fax: +386 4 281 62 13 (Charges depending on provider) E-mail: [email protected]

Order No. PC2011-V1.1 Printed in Slovenia Dispo 34807, c4bs No. 7827 fb 2674 440101 WS 11092.0

Printed on elementary chlorine-free bleached paper.

All rights reserved. Trademarks mentioned in this document are the property of Sat Control d.o.o., its affiliates, or their respective owners.

Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.