Certicate of Analysis Powered by Condent Analysis by Havard Industries 1 of 3

3Chi Sample: 2105EST0625.2213 275 Medical Drive Strain: CDT Super Lemon Haze Carmel, IN 46082 Batch#: 210420-CDT-SLH; Batch Size: g [email protected] Sample Received: 05/17/2021 (405) 599-1234 Report Created: 05/17/2021 Lic. # Expires: 08/15/2021 3Chi Delta-8 THC Vape Cartridge - CDT Super Lemon Haze Concentrates & Extracts, Distillate Harvest Process Lot: ; METRC Batch: ; METRC Sample:

Safety

Pass Pass Pass Pesticides Microbials Mycotoxins

Pass Pass Pass Solvents Metals Foreign Matter

Cannabinoids potency by HPLC-UV, CANSOP001 Date Tested: 05/05/2021

ND ND 79.92% NT Total THC Total CBD Total Moisture

Analyte LOQ Mass Mass CBN Δ8-THC Δ10-THC % % mg/g THCa 0.00 ND ND Δ9-THC 0.00 ND ND Δ8-THC 0.00 79.70 797.0 THCV 0.00 ND ND CBDa 0.00 ND ND CBD 0.00 ND ND CBN 0.00 0.10 1.0 CBGa 0.00 ND ND CBG 0.00 ND ND CBC 0.00 ND ND Δ10-THC 0.00 0.12 1.2 Total 79.92 799.2 99.7% Test results only relate to the sample as received. Cannabinoids are corrected to dry weight. Total THC = AnalyzedTHCa * 0.877 + ∆9-THC. by Havard Industries Total CBD = CBDa * 0.877 + CBD. LOQ = Limit of Quantitation.

Havard Industries Condent Cannabis 6300 Boucher Dr. All Rights Reserved Edmond, OK support@condentcannabis.com Jeffery Havard (405) 205-8757 (866) 506-5866 Lab Manager, Havard Industries www.condentcannabis.com Lic# LAAA-8SPC-5FH4

ND = Not Detected, NT = Not tested. Certicate of Analysis Powered by Condent Cannabis Analysis by Havard Industries 2 of 3

3Chi Sample: 2105EST0625.2213 275 Medical Drive Strain: CDT Super Lemon Haze Carmel, IN 46082 Batch#: 210420-CDT-SLH; Batch Size: g [email protected] Sample Received: 05/17/2021 (405) 599-1234 Report Created: 05/17/2021 Lic. # Expires: 08/15/2021 3Chi Delta-8 THC Vape Cartridge - CDT Super Lemon Haze Concentrates & Extracts, Distillate Harvest Process Lot: ; METRC Batch: ; METRC Sample:

Terpenes Cannabinoid by GC-FID, CANSOP005 Primary Aromas Date Tested: 05/16/2021 05/12/2021

Analyte LOQ Mass Mass % % mg/g 3.41% β-Pinene 0.00 1.53 15.3 Total Terpenes Terpinolene 0.00 0.71 7.1 δ- 0.00 0.46 4.6 Ocimene 0.00 0.22 2.2 β- 0.00 0.14 1.4 α-Pinene 0.00 0.12 1.2 Pine β-Myrcene 0.00 0.12 1.2 α-Humulene 0.00 0.03 0.3 α-Terpinene 0.00 0.02 0.2 3-Carene 0.00 0.02 0.2 trans-Nerolidol 0.00 0.01 0.1 Turpentine cis-Nerolidol 0.00 0.01 0.1 γ-Terpinene 0.00 0.01 0.1 Caryophyllene Oxide 0.00 0.00 0.0 α-Bisabolol 0.00 ND ND Camphene 0.00 ND ND Eucalyptol 0.00 ND ND Orange Geraniol 0.00 ND ND Guaiol 0.00 ND ND Isopulegol 0.00 ND ND Linalool 0.00 ND ND p-Cymene 0.00 ND ND Earthy Total 3.41 34.1

Analyzed by Havard IndustriesCinnamon

Test results only relate to the sample as received. Terpenes are corrected to dry weight. ND = Not Detected, NT = Not tested

Havard Industries Condent Cannabis 6300 Boucher Dr. All Rights Reserved Edmond, OK support@condentcannabis.com Jeffery Havard (405) 205-8757 (866) 506-5866 Lab Manager, Havard Industries www.condentcannabis.com Lic# LAAA-8SPC-5FH4

ND = Not Detected, NT = Not tested. Certicate of Analysis Powered by Condent Cannabis Analysis by Havard Industries 3 of 3

3Chi Sample: 2105EST0625.2213 275 Medical Drive Strain: CDT Super Lemon Haze Carmel, IN 46082 Batch#: 210420-CDT-SLH; Batch Size: g [email protected] Sample Received: 05/17/2021 (405) 599-1234 Report Created: 05/17/2021 Lic. # Expires: 08/15/2021 3Chi Delta-8 THC Vape Cartridge - CDT Super Lemon Haze Concentrates & Extracts, Distillate Harvest Process Lot: ; METRC Batch: ; METRC Sample:

Pesticides Date Tested: 05/06/2021 Pass Microbials Date Tested: 04/30/2021 Pass Residuals Pesticides by LC/MS/MS, CANSOP004 Biological Analysis: qPCR, CANSOP 20, Aspergillus by qPCR Analyte LOQ Limit Mass Status Analyte Limit Mass Status PPM PPM PPM CFU/g CFU/g Abamectin 0.500 ND Pass Aerobic Bacteria 100000 NR NT Azoxystrobin 0.200 ND Pass Aspergillus avus 1 ND Pass Bifenazate 0.200 ND Pass Aspergillus fumigatus 1 ND Pass Etoxazole 0.200 ND Pass Aspergillus niger 1 ND Pass Imazalil 0.200 ND Pass Aspergillus terreus 1 ND Pass Imidacloprid 0.400 ND Pass Coliforms 10000 NR NT Malathion 0.200 ND Pass E. Coli 1 ND Pass Myclobutanil 0.200 ND Pass Salmonella 1 ND Pass Permethrin 0.200 ND Pass Yeast & Mold 10000 NR NT Spinosad 0.200 ND Pass Spiromesifen 0.200 ND Pass Spirotetramat 0.200 ND Pass Residual Solvents Pass Tebuconazole 0.400 ND Pass Date Tested: 05/12/2021 Residuals Solvents by Headspace GC, CANSOP006 Analyte LOQ Limit Mass Status PPM PPM PPM Acetone 1.000 1000.000 ND Pass Benzene 1.000 2.000 ND Pass Ethanol 1.000 5000.000 ND Pass Ethyl-Acetate 1.000 1000.000 ND Pass Heptane 1.000 1000.000 ND Pass Hexanes 1.000 60.000 ND Pass Isopropanol 1.000 1000.000 ND Pass Methanol 1.000 600.000 ND Pass n-Butane 1.000 1000.000 ND Pass Pentane 1.000 1000.000 ND Pass Propane 1.000 1000.000 ND Pass Toluene 1.000 180.000 ND Pass Xylenes 1.000 430.000 ND Pass Test results only relate to the sample as received.

Heavy MetalsDate Tested: 05/12/2021 Pass Mycotoxins Date Tested: 05/06/2021 Pass Heavy Metals by ICP, CANSOP007 Mycotoxins by HPLC, CANSOP003 Analyte LOQ Limit Mass Status Analyte LOQ Limit Mass Status PPB PPB PPB PPB PPB PPB Arsenic 10.000 200.000

Havard Industries Condent Cannabis 6300 Boucher Dr. All Rights Reserved Edmond, OK support@condentcannabis.com Jeffery Havard (405) 205-8757 (866) 506-5866 Lab Manager, Havard Industries www.condentcannabis.com Lic# LAAA-8SPC-5FH4

ND = Not Detected, NT = Not tested.