Aubt Qualification Test
AUBT PRACTICAL EXAMINATION WORKSHEET
Name:______
Base Metal Sample
- Detect any backscatter signals in sample provided.
Base Metal Sample #:
2. Identify the pattern type of any backscatter signals and apply the appropriate procedure.
Pattern Type: I II III IV
3. Store and recall to a document (or print) the backscatter signals. Images required:
· 10 MHz backscatter of Reference block: Image#: ______
· 10 MHz backscatter of Indication from base metal sample: Image#: ______
· 5 MHz backscatter of Indication displayed appropriately: Image#: ______
· Spectrum Analysis of both Reference and Indication: Image#: ______
· Velocity Ratio Method 1 - Show images of 1st and 2nd backwall signals from both L-wave and S-wave with cursors visible: Image#: ______
· Velocity Ratio Method 2 – Show image of backwall signal (or interface) with absolute curser visible from both L-wave and S-wave: Image#: ______
· Spatial Averaging of Indication: Image#: ______
· Spatial Averaging of Reference block signal: Image#: ______
4. Complete the information requested for all sections below. Then, circle methods used for Analysis according to the appropriate procedure.
- 10 MHz Backscatter: Image#: _____
- 5 MHz Backscatter: Image#: ______
- Spectrum Analysis
- Attenuation increase with frequency? Yes __ No _
- If Yes, Attenuation at 10 MHz: dB
Attenuation at 5 MHz: dB
- Velocity Ratio:
· Method 1:
- Base Metal Sample L-wave (µs):
- Base Metal Sample S-wave (µs):
- Velocity Ratio: ______
· Method 2:
d. Cal Block Delta t1 L-wave (µs):
e. Cal Block Delta t2 L-wave (µs):
- Delay (L-wave): ______
- Cal Block Delta t1 S-wave (µs):
- Cal Block Delta t2 S-wave (µs):
- Delay (S-wave): ______
- Base Metal Sample uncorrected L-Wave (µs): ______
- Base Metal Sample uncorrected S-Wave(µs): ______
- Velocity Ratio (corrected): ______
- Spacial Avaraging
Base Metal Flaws Detected: Yes No ___
Circle Flaw Type(s) Detected:
· HTHA, Laminations, Inclusions
Base Metal HTHA Detected: Yes No ____
Height of HTHA if Detected: ______
Weld HAZ Samples
- Detect any weld HAZ indications.
- Use ABSA procedure to make the correct call.
- Store and recall (or print) all relevant supporting data. Images required:
· A-Scan with wedge delay and ID cursors set
- Wedge Delay in µs: ______
- Sample Thickness in µs: ______
- Sample Thickness in inches: ______
- ID Cursor Value in µs: ______
· Spectrum analysis of reference and suspect signal
Flaws Detected: Yes No ___
Circle Flaw Type(s) Detected:
· HTHA, ID Crack, Lack of Penetration ( LOP ), Lack of Fusion ( LOF ), Porosity, Slag
Weld/HAZ HTHA Detected: Yes No ___
Flaw Size:
- Start location: ______
- Length: ______
- Height: ______
- Depth: ______