Meta Information Param
FICHE META_INFORMATION_PARAMETRES
(à remplir par le responsable du paramètre)
1. Nom du DATASET / Data SET NAME
Data set Name : T-S-O2 bottle and CTD data at sampling depth
2. PROJET-ETUDE / PROJECT TITLE
Campaign NAME : GEOVIDE
Date begin : 15 May 2014
Date end : 30 june 2014
Chief Scientist: Sarthou Géraldine
Address: UMR CNRS 6539/LEMAR/IUEM
Technopole Brest Iroise
Place Nicolas Copernic
F - 29280 Plouzane
Phone: (33) (0)2 98 49 86 55
Chief Mission:
Address:
3. OPERATION CAMPAGNE PIs / OPERATION CAMPAIGN&PIs
Sampling method: WOCE standards
Station number-Cast number : All hydrographic stations
Operation code:
4. RESPONSABLE SCIENTIFIQUE du paramètre / PI of the parameter
5. DATASET contact
6. INFORMATION GEOGRAPHIQUES / GEOGRAPHIC INFORMATION
Predefined site (if relevant):
Location: North Atlantic
LATITUDE: 40°N – 60°N
LONGITUDE: 54°W – 9°W
7. DESCRIPTION DES INSTRUMENTS / INSTRUMENTS DESCRIPTION
Instrument Type: CTD-O2
Manufacturer: SeaBird
Model: SBE911
Instrument Features / Calibration:
Metrology before and after survey for temperature and pressure
Least-square method to fit to the chemical analysis of the samples for salinity and dissolved oxygen
8. DESCRIPTION DES PARAMETRES / PARAMETERS DESCRIPTION
8.1. Ce qui a été collecté, mesuré et comment / How was the parameter collected and measured (include references for analytical methods)?
Sampling: at standard levels and extrema.
Analytical procedure: (briefly, could be a short recall to a published reference):
Described in Branellec and Thierry, 2013
Units: described in the data files
Sensor Precision:
Temperature: 0.001°C
Salinity: 0.002
Dissolved oxygen: 0.05 ml/l or 2.2µmol/kg
8.2. Décrire quels types de données sont nécessaires pour vous compléter votre propre jeu de données avant envoi à la base de données, et estimer le délai avant la disponibilité de vos données pour la base de données / Post-cruise data analysis/treatment required, and the time frame for this
Final calibration of the probes (September 2014) is necessary to finalize the calibration.
Estimated Date of Delivery :
Pre-calibrated data: November 2014
Calibrated data: June 2015
9. REFERENCES BIBLIOGRAPHIQUES
Branellec, Pierre and Virginie Thierry, 2013: OVIDE2010 CTD-02 Cruise report. ODE/LPO/13-01.
http://archimer.ifremer.fr/doc/00210/32134/